This document is an excerpt from the EUR-Lex website
Document 52012XC1229(02)
Commission communication in the framework of the implementation of Commission Regulation (EU) No 547/2012 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for water pumps Text with EEA relevance (Publication of titles and references of transitional methods of measurement for the implementation of Commission Regulation (EU) No 547/2012 and, in particular, Annex III and IV thereof)
Commission communication in the framework of the implementation of Commission Regulation (EU) No 547/2012 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for water pumps Text with EEA relevance (Publication of titles and references of transitional methods of measurement for the implementation of Commission Regulation (EU) No 547/2012 and, in particular, Annex III and IV thereof)
Commission communication in the framework of the implementation of Commission Regulation (EU) No 547/2012 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for water pumps Text with EEA relevance (Publication of titles and references of transitional methods of measurement for the implementation of Commission Regulation (EU) No 547/2012 and, in particular, Annex III and IV thereof)
OJ C 402, 29.12.2012, p. 17–19
(BG, ES, CS, DA, DE, ET, EL, EN, FR, IT, LV, LT, HU, MT, NL, PL, PT, RO, SK, SL, FI, SV)
29.12.2012 |
EN |
Official Journal of the European Union |
C 402/17 |
Commission communication in the framework of the implementation of Commission Regulation (EU) No 547/2012 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for water pumps
(Text with EEA relevance)
(Publication of titles and references of transitional methods of measurement (1) for the implementation of Commission Regulation (EU) No 547/2012 and, in particular, Annex III and IV thereof)
2012/C 402/07
For the purposes of verification of compliance with the requirements of Commission Regulation (EU) No 547/2012 pump efficiency tests shall be carried out as follows.
1. |
All measurement shall be done according to ISO EN 9906 Class 2b. The exception specified in that standard for total tolerance of pump efficiency for pump power input of 10kW and below shall not be considered. |
2. |
The duration of the test shall be sufficient to obtain repeatable results; especially run-in effects shall be considered. Run-in effects may take up to 1 day operating time. |
3. |
All measurements shall be made under steady state conditions. |
4. |
The tests should be conducted under conditions where cavitation does not affect the performance of the pump. |
5. |
Pump efficiency is measured at the head and flow corresponding to the best efficiency point (BEP), part load (PL), and over load (OL) for full (untrimmed) impeller diameter with clean cold water, as defined in Commission Regulation (EU) No 547/2012. |
6. |
Vertical multistage water pumps are to be tested with a three stage (i = 3) version. Submersible multistage water pumps are to be tested with a nine stage (i = 9) version. If this number of stages is not offered within the specific product range, the next higher number of stages within the product range is to be chosen for verification testing. |
7. |
A minimum of seven test points shall be taken for all verification tests within the range of 60 % to 120 % around the expected flow at the BEP. Four of these points shall be spaced between 60 % and 95 %, two between 105 % and 120 %, and one point chosen within 95 % to 105 % of the expected flow at the BEP. For the determination of the flow corresponding to BEP, PL, and OL, the flow-efficiency fitting curve must be represented by an appropriate mathematical expression. In the range of flow rates from PL to OL, the curve represented by the mathematical expression shall have only one maximum, and the second derivative of the mathematical expression must be negative. Appropriate methods for drawing the flow-efficiency fitting curve are polynomials of third order or spline functions. Alternatively, the nominal best flow value on the water pump's name plate or from the manufacturer's test reports can be chosen if provided. |
8. |
The required minimum efficiencies shall be calculated as set out in Annex III of Commission Regulation (EU) No 547/2012. The minimum efficiency index (MEI) for product information requirements shall be derived using the same equation at BEP evaluated for the C-value and according to Table 1. The second decimal place of the MEI shall be determined by a linear interpolation of the C-values corresponding to the neighbouring MEI values in Table 1, and by rounding to the next lower MEI. If the C-value is smaller than the one corresponding to a MEI of 0,70, only ‘MEI > 0,70’ shall be provided as information. Table 1 Minimum efficiency index (MEI) and its corresponding C-value depending on the pump type and speed
|
9. |
The maximum permissible random uncertainty er,max as a percentage of the arithmetically averaged value of the measured quantity is: Table 2 Maximum permissible random uncertainty er,max
|
10. |
The maximum permissible measurement device uncertainty es,max as a percentage of the arithmetically averaged value of the measured quantity is: Table 3 Maximum permissible measurement device uncertainty es,max
|
11. |
The maximum overall tolerance for measurements is ttot = 5 %. Measurement devices shall be chosen not to exceed this overall tolerance. Consequently, measured pump efficiencies for BEP, PL, and OL are not allowed to fall below the threshold value defined as follows: |
12. |
For the purpose of conformity assessment, the manufacturer shall prepare and keep available upon request from market surveillance authorities test reports and all documentation needed to support the information declared by the manufacturer. The test reports shall contain all relevant measurement information including but not limited to:
description of the test sequence followed (e.g. to arrive at equilibrium conditions as applicable). |
(1) It is intended that these transitional methods will ultimately be replaced by harmonised standard (pr)EN 16480. When available, reference(s) to the harmonised standard will be published in the Official Journal of the European Union in accordance with Articles 9 and 10 of Directive 2009/125/EC.