Choose the experimental features you want to try

This document is an excerpt from the EUR-Lex website

Document 02006L0025-20190726

Consolidated text: Directive 2006/25/EC of the European Parliament and of the Council of 5 April 2006 on the minimum health and safety requirements regarding the exposure of workers to risks arising from physical agents (artificial optical radiation) (19th individual Directive within the meaning of Article 16(1) of Directive 89/391/EEC)

ELI: http://data.europa.eu/eli/dir/2006/25/2019-07-26

02006L0025 — EN — 26.07.2019 — 004.001


This text is meant purely as a documentation tool and has no legal effect. The Union's institutions do not assume any liability for its contents. The authentic versions of the relevant acts, including their preambles, are those published in the Official Journal of the European Union and available in EUR-Lex. Those official texts are directly accessible through the links embedded in this document

►B

DIRECTIVE 2006/25/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL

of 5 April 2006

on the minimum health and safety requirements regarding the exposure of workers to risks arising from physical agents (artificial optical radiation) (19th individual Directive within the meaning of Article 16(1) of Directive 89/391/EEC)

(OJ L 114 27.4.2006, p. 38)

Amended by:

 

 

Official Journal

  No

page

date

►M1

DIRECTIVE 2007/30/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL Text with EEA relevance of 20 June 2007

  L 165

21

27.6.2007

 M2

REGULATION (EC) No 1137/2008 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 22 October 2008

  L 311

1

21.11.2008

►M3

COUNCIL DIRECTIVE 2013/64/EU of 17 December 2013

  L 353

8

28.12.2013

►M4

REGULATION (EU) 2019/1243 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 20 June 2019

  L 198

241

25.7.2019




▼B

DIRECTIVE 2006/25/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL

of 5 April 2006

on the minimum health and safety requirements regarding the exposure of workers to risks arising from physical agents (artificial optical radiation) (19th individual Directive within the meaning of Article 16(1) of Directive 89/391/EEC)



SECTION I

GENERAL PROVISIONS

Article 1

Aim and scope

1.  This Directive, which is the 19th individual Directive within the meaning of Article 16(l) of Directive 89/391/EEC, lays down minimum requirements for the protection of workers from risks to their health and safety arising or likely to arise from exposure to artificial optical radiation during their work.

2.  This Directive refers to the risk to the health and safety of workers due to adverse effects caused by exposure to artificial optical radiation to the eyes and to the skin.

3.  Directive 89/391/EEC shall apply fully to the whole area referred to in paragraph 1, without prejudice to more stringent and/or more specific provisions contained in this Directive.

Article 2

Definitions

For the purposes of this Directive, the following definitions shall apply:

(a) optical radiation: any electromagnetic radiation in the wavelength range between 100 nm and 1 mm. The spectrum of optical radiation is divided into ultraviolet radiation, visible radiation and infrared radiation:

(i) ultraviolet radiation: optical radiation of wavelength range between 100 nm and 400 nm. The ultraviolet region is divided into UVA (315-400 nm), UVB (280-315 nm) and UVC (100-280 nm);

(ii) visible radiation: optical radiation of wavelength range between 380 nm and 780 nm;

(iii) infrared radiation: optical radiation of wavelength range between 780 nm and 1 mm. The infrared region is divided into IRA (780-1 400  nm), IRB (1 400 -3 000  nm) and IRC (3 000  nm-1 mm);

(b) laser (light amplification by stimulated emission of radiation): any device which can be made to produce or amplify electromagnetic radiation in the optical radiation wavelength range primarily by the process of controlled stimulated emission;

(c) laser radiation: optical radiation from a laser;

(d) non-coherent radiation: any optical radiation other than laser radiation;

(e) exposure limit values: limits on exposure to optical radiation which are based directly on established health effects and biological considerations. Compliance with these limits will ensure that workers exposed to artificial sources of optical radiation are protected against all known adverse health effects;

(f) irradiance (E) or power density: the radiant power incident per unit area upon a surface expressed in watts per square metre (W m-2);

(g) radiant exposure (H): the time integral of the irradiance, expressed in joules per square metre (J m-2);

(h) radiance (L): the radiant flux or power output per unit solid angle per unit area, expressed in watts per square metre per steradian (W m-2 sr-1);

(i) level: the combination of irradiance, radiant exposure and radiance to which a worker is exposed.

Article 3

Exposure limit values

1.  The exposure limit values for non-coherent radiation, other than that emitted by natural sources of optical radiation, are as set out in Annex I.

2.  The exposure limit values for laser radiation are as set out in Annex II.



SECTION II

OBLIGATIONS OF EMPLOYERS

Article 4

Determination of exposure and assessment of risks

1.  In carrying out the obligations laid down in Articles 6(3) and 9(1) of Directive 89/391/EEC, the employer, in the case of workers exposed to artificial sources of optical radiation, shall assess and, if necessary, measure and/or calculate the levels of exposure to optical radiation to which workers are likely to be exposed so that the measures needed to restrict exposure to the applicable limits can be identified and put into effect. The methodology applied in assessment, measurement and/or calculations shall follow the standards of the International Electrotechnical Commission (IEC) in respect of laser radiation and the recommendations of the International Commission on Illumination (CIE) and the European Committee for Standardisation (CEN) in respect of non-coherent radiation. In exposure situations which are not covered by these standards and recommendations, and until appropriate EU standards or recommendations become available, assessment, measurement and/or calculations shall be carried out using available national or international science-based guidelines. In both exposure situations, the assessment may take account of data provided by the manufacturers of the equipment when it is covered by relevant Community Directives.

2.  The assessment, measurement and/or calculations referred to in paragraph 1 shall be planned and carried out by competent services or persons at suitable intervals, taking particular account of the provisions of Articles 7 and 11 of Directive 89/391/EEC concerning the necessary competent services or persons and the consultation and participation of workers. The data obtained from the assessment, including those obtained from the measurement and/or calculation of the level of exposure referred to in paragraph 1 shall be preserved in a suitable form so as to permit their consultation at a later stage.

3.  Pursuant to Article 6(3) of Directive 89/391/EEC, the employer shall give particular attention, when carrying out the risk assessment, to the following:

(a) the level, wavelength range and duration of exposure to artificial sources of optical radiation;

(b) the exposure limit values referred to in Article 3 of this Directive;

(c) any effects concerning the health and safety of workers belonging to particularly sensitive risk groups;

(d) any possible effects on workers’ health and safety resulting from workplace interactions between optical radiation and photosensitising chemical substances;

(e) any indirect effects such as temporary blinding, explosion or fire;

(f) the existence of replacement equipment designed to reduce the levels of exposure to artificial optical radiation;

(g) appropriate information obtained from health surveillance, including published information, as far as possible;

(h) multiple sources of exposure to artificial optical radiation;

(i) a classification applied to a laser as defined in accordance with the relevant IEC standard and, in relation to any artificial source likely to cause damage similar to that of a laser of class 3B or 4, any similar classification;

(j) information provided by the manufacturers of optical radiation sources and associated work equipment in accordance with the relevant Community Directives.

4.  The employer shall be in possession of an assessment of the risk in accordance with Article 9(1)(a) of Directive 89/391/EEC and shall identify which measures must be taken in accordance with Articles 5 and 6 of this Directive. The risk assessment shall be recorded on a suitable medium, according to national law and practice; it may include a justification by the employer that the nature and extent of the risks related to optical radiation make a further, detailed risk assessment unnecessary. The risk assessment shall be updated on a regular basis, particularly if there have been significant changes which could render it out of date, or if the results of health surveillance show it to be necessary.

Article 5

Provisions aimed at avoiding or reducing risks

1.  Taking account of technical progress and of the availability of measures to control the risk at source, the risks arising from exposure to artificial optical radiation shall be eliminated or reduced to a minimum.

The reduction of risks arising from exposure to artificial optical radiation shall be based on the general principles of prevention set out in Directive 89/391/EEC.

2.  Where the risk assessment carried out in accordance with Article 4(1) for workers exposed to artificial sources of optical radiation indicates any possibility that the exposure limit values may be exceeded, the employer shall devise and implement an action plan comprising technical and/or organisational measures designed to prevent the exposure exceeding the limit values, taking into account in particular:

(a) other working methods that reduce the risk from optical radiation;

(b) the choice of equipment emitting less optical radiation, taking account of the work to be done;

(c) technical measures to reduce the emission of optical radiation including, where necessary, the use of interlocks, shielding or similar health protection mechanisms;

(d) appropriate maintenance programmes for work equipment, workplaces and workstation systems;

(e) the design and layout of workplaces and workstations;

(f) limitation of the duration and level of the exposure;

(g) the availability of appropriate personal protective equipment;

(h) the instructions of the manufacturer of the equipment where it is covered by relevant Community Directives.

3.  On the basis of the risk assessment carried out in accordance with Article 4, workplaces where workers could be exposed to levels of optical radiation from artificial sources exceeding the exposure limit values shall be indicated by appropriate signs in accordance with Council Directive 92/58/EEC of 24 June 1992 on the minimum requirements for the provision of safety and/or health signs at work (9th individual Directive within the meaning of Article 16(1) of Directive 89/391/EEC) ( 1 ). The areas in question shall be identified, and access to them limited where this is technically possible and where there is a risk that the exposure limit values could be exceeded.

4.  Workers shall not be exposed above the exposure limit values. In any event, if, despite the measures taken by the employer to comply with this Directive in respect of artificial sources of optical radiation, the exposure limit values are exceeded, the employer shall take immediate action to reduce exposure below the exposure limit values. The employer shall identify the reasons why the exposure limit values have been exceeded and shall adapt the protection and prevention measures accordingly in order to prevent them being exceeded again.

5.  Pursuant to Article 15 of Directive 89/391/EEC, the employer shall adapt the measures referred to in this Article to the requirements of workers belonging to particularly sensitive risk groups.

Article 6

Worker information and training

Without prejudice to Articles 10 and 12 of Directive 89/391/EEC, the employer shall ensure that workers who are exposed to risks from artificial optical radiation at work and/or their representatives receive any necessary information and training relating to the outcome of the risk assessment provided for in Article 4 of this Directive, concerning in particular:

(a) measures taken to implement this Directive;

(b) the exposure limit values and the associated potential risks;

(c) the results of the assessment, measurement and/or calculations of the levels of exposure to artificial optical radiation carried out in accordance with Article 4 of this Directive together with an explanation of their significance and potential risks;

(d) how to detect adverse health effects of exposure and how to report them;

(e) the circumstances in which workers are entitled to health surveillance;

(f) safe working practices to minimise risks from exposure;

(g) proper use of appropriate personal protective equipment.

Article 7

Consultation and participation of workers

Consultation and participation of workers and/or of their representatives shall take place in accordance with Article 11 of Directive 89/391/EEC on the matters covered by this Directive.



SECTION III

MISCELLANEOUS PROVISIONS

Article 8

Health surveillance

1.  With the objectives of the prevention and timely detection of any adverse health effects, as well as the prevention of any long-term health risks and any risk of chronic diseases, resulting from exposure to optical radiation, Member States shall adopt provisions to ensure appropriate health surveillance of workers pursuant to Article 14 of Directive 89/391/EEC.

2.  Member States shall ensure that health surveillance is carried out by a doctor, an occupational health professional or a medical authority responsible for health surveillance in accordance with national law and practice.

3.  Member States shall establish arrangements to ensure that, for each worker who undergoes health surveillance in accordance with paragraph 1, individual health records are made and kept up to date. Health records shall contain a summary of the results of the health surveillance carried out. They shall be kept in a suitable form so as to permit consultation at a later date, taking into account any confidentiality. Copies of the appropriate records shall be supplied to the competent authority on request, taking into account any confidentiality. The employer shall take appropriate measures to ensure that the doctor, the occupational health professional or the medical authority responsible for the health surveillance, as determined by Member States as appropriate, has access to the results of the risk assessment referred to in Article 4 where such results may be relevant to the health surveillance. Individual workers shall, at their request, have access to their own personal health records.

4.  In any event, where exposure above the limit values is detected, a medical examination shall be made available to the worker(s) concerned in accordance with national law and practice. This medical examination shall also be carried out where, as a result of health surveillance, a worker is found to have an identifiable disease or adverse health effect which is considered by a doctor or occupational health professional to be the result of exposure to artificial optical radiation at work. In both cases, when limit values are exceeded or adverse health effects (including diseases) are identified:

(a) the worker shall be informed by the doctor or other suitably qualified person of the result which relates to him personally. He shall, in particular, receive information and advice regarding any health surveillance which he should undergo following the end of exposure;

(b) the employer shall be informed of any significant findings of the health surveillance, taking into account any medical confidentiality;

(c) the employer shall:

 review the risk assessment carried out pursuant to Article 4,

 review the measures provided for to eliminate or reduce risks pursuant to Article 5,

 take into account the advice of the occupational health professional or other suitably qualified person or the competent authority in implementing any measure required to eliminate or reduce risk in accordance with Article 5, and

 arrange continued health surveillance and provide for a review of the health status of any other worker who has been similarly exposed. In such cases, the competent doctor or occupational health professional or the competent authority may propose that the exposed persons undergo a medical examination.

Article 9

Penalties

Member States shall provide for adequate penalties to be applicable in the event of infringement of the national legislation adopted pursuant to this Directive. These penalties must be effective, proportionate and dissuasive.

▼M4

Article 10

Amendment of the Annexes

The Commission is empowered to adopt delegated acts in accordance with Article 10a to make strictly technical amendments to the Annexes, in order to take account of technical harmonisation and standardisation with regard to the design, building, manufacture or construction of work equipment or workplaces, technical progress, changes in harmonised European standards or international specifications and new scientific findings concerning occupational exposure to optical radiation. Those amendments shall not result in a modification of the exposure limit values set out in the Annexes.

Where, in duly justified and exceptional cases involving imminent, direct and serious risks to workers’ and other persons’ physical health and safety, imperative grounds of urgency require action in a very short timeframe, the procedure provided for in Article 10b shall apply to delegated acts adopted pursuant to this Article.

▼M4

Article 10a

Exercise of the delegation

1.  The power to adopt delegated acts is conferred on the Commission subject to the conditions laid down in this Article.

2.  The power to adopt delegated acts referred to in Article 10 shall be conferred on the Commission for a period of five years from 26 July 2019. The Commission shall draw up a report in respect of the delegation of power not later than nine months before the end of the five-year period. The delegation of power shall be tacitly extended for periods of an identical duration, unless the European Parliament or the Council opposes such extension not later than three months before the end of each period.

3.  The delegation of power referred to in Article 10 may be revoked at any time by the European Parliament or by the Council. A decision to revoke shall put an end to the delegation of the power specified in that decision. It shall take effect the day following the publication of the decision in the Official Journal of the European Union or at a later date specified therein. It shall not affect the validity of any delegated acts already in force.

4.  Before adopting a delegated act, the Commission shall consult experts designated by each Member State in accordance with the principles laid down in the Interinstitutional Agreement of 13 April 2016 on Better Law-Making ( 2 ).

5.  As soon as it adopts a delegated act, the Commission shall notify it simultaneously to the European Parliament and to the Council.

6.  A delegated act adopted pursuant to Article 10 shall enter into force only if no objection has been expressed either by the European Parliament or the Council within a period of two months of notification of that act to the European Parliament and the Council or if, before the expiry of that period, the European Parliament and the Council have both informed the Commission that they will not object. That period shall be extended by two months at the initiative of the European Parliament or of the Council.

Article 10b

Urgency procedure

1.  Delegated acts adopted under this Article shall enter into force without delay and shall apply as long as no objection is expressed in accordance with paragraph 2. The notification of a delegated act to the European Parliament and the Council shall state the reasons for the use of the urgency procedure.

2.  Either the European Parliament or the Council may object to a delegated act in accordance with the procedure referred to in Article 10a(6). In such a case, the Commission shall repeal the act immediately following the notification of the decision to object by the European Parliament or by the Council.

▼M4 —————

▼B



SECTION IV

FINAL PROVISIONS

▼M1 —————

▼B

Article 13

Practical guide

In order to facilitate implementation of this Directive the Commission shall draw up a practical guide to the provisions of Articles 4 and 5 and Annexes I and II.

Article 14

Transposition

1.  Member States shall bring into force the laws, regulations and administrative provisions necessary to comply with this Directive by 27 April 2010. They shall forthwith inform the Commission thereof.

When Member States adopt these measures, they shall contain a reference to this Directive or shall be accompanied by such reference on the occasion of their official publication. The methods of making such reference shall be laid down by Member States.

2.  Member States shall communicate to the Commission the text of the provisions of national law which they adopt or have already adopted in the field covered by this Directive.

▼M3

Article 14a

1.  Without prejudice to the general principles of protection and prevention in the area of health and safety of workers, France may, until 31 December 2017, derogate from the application of the provisions necessary to comply with this Directive in Mayotte as an outermost region within the meaning of Article 349 of the Treaty on the Functioning of the European Union (hereinafter ‘Mayotte’), provided that such application requires specific technical facilities that are not available in Mayotte.

The first subparagraph does not apply to the obligations set out in Article 5(1) of this Directive, or to the provisions of this Directive which reflect the general principles laid down in Directive 89/391/EEC.

2.  All derogations from this Directive resulting from the application of measures existing on 1 January 2014 or from the adoption of new measures shall be preceded by a consultation with the social partners in accordance with national law and practice. Such derogations shall be applied under conditions which, taking into account the particular circumstances prevailing in Mayotte, guarantee that the resulting risks for workers are reduced to a minimum and that the workers concerned benefit from reinforced health surveillance.

3.  The national derogating measures shall be reviewed every year, after consultation with the social partners, and shall be withdrawn as soon as the circumstances justifying them no longer subsist.

▼B

Article 15

Entry into force

This Directive shall enter into force on the day of its publication in the Official Journal of the European Union.

Article 16

Addressees

This Directive is addressed to the Member States.




ANNEX I

Non-coherent optical radiation

The biophysically relevant exposure values to optical radiation can be determined with the formulae below. The formulae to be used depend on the range of radiation emitted by the source and the results should be compared with the corresponding exposure limit values indicated in Table 1.1. More than one exposure value and corresponding exposure limit can be relevant for a given source of optical radiation.

Numbering (a) to (o) refers to corresponding rows of Table 1.1.



(a)

image

(Heff is only relevant in the range 180 to 400 nm)

(b)

image

(HUVA is only relevant in the range 315 to 400 nm)

(c), (d)

image

(LB is only relevant in the range 300 to 700 nm)

(e), (f)

image

(EB is only relevant in the range 300 to 700 nm)

(g) to (l)

image

(See Table 1.1 for appropriate values of λ1 and λ2)

(m), (n)

image

(EIR is only relevant in the range 780 to 3 000  nm)

(o)

image

(Hskin is only relevant in the range 380 to 3 000  nm)

For the purposes of this Directive, the formulae above can be replaced by the following expressions and the use of discrete values as set out in the following tables:



(a)

image

and

image

(b)

image

and

image

(c), (d)

image

 

(e), (f)

image

 

(g) to (l)

image

(See Table 1.1 for appropriate values of λ1 and λ2)

(m), (n)

image

 

(o)

image

and

image

Notes:

Eλ (λ,t), Eλ

spectral irradiance or spectral power density: the radiant power incident per unit area upon a surface, expressed in watts per square metre per nanometre [W m-2 nm-1]; values of Eλ (λ, t) and Eλ come from measurements or may be provided by the manufacturer of the equipment;

Eeff

effective irradiance (UV range): calculated irradiance within the UV wavelength range 180 to 400 nm spectrally weighted by S (λ), expressed in watts per square metre [W m-2];

H

radiant exposure: the time integral of the irradiance, expressed in joules per square metre [J m-2];

Heff

effective radiant exposure: radiant exposure spectrally weighted by S (λ), expressed in joules per square metre [J m-2];

EUVA

total irradiance (UVA): calculated irradiance within the UVA wavelength range 315 to 400 nm, expressed in watts per square metre [W m-2];

HUVA

radiant exposure: the time and wavelength integral or sum of the irradiance within the UVA wavelength range 315 to 400 nm, expressed in joules per square metre [J m-2];

S (λ)

spectral weighting taking into account the wavelength dependence of the health effects of UV radiation on eye and skin, (Table 1.2) [dimensionless];

t, Δt

time, duration of the exposure, expressed in seconds [s];

λ

wavelength, expressed in nanometres [nm];

Δ λ

bandwidth, expressed in nanometres [nm], of the calculation or measurement intervals;

Lλ (λ), Lλ

spectral radiance of the source expressed in watts per square metre per steradian per nanometre [W m-2 sr -1 nm-1];

R (λ)

spectral weighting taking into account the wavelength dependence of the thermal injury caused to the eye by visible and IRA radiation (Table 1.3) [dimensionless];

LR

effective radiance(thermal injury): calculated radiance spectrally weighted by R (λ) expressed in watts per square metre per steradian [W m-2 sr -1];

B (λ)

spectral weighting taking into account the wavelength dependence of the photochemical injury caused to the eye by blue light radiation (Table 1.3) [dimensionless];

LB

effective radiance(blue light): calculated radiance spectrally weighted by B (λ), expressed in watts per square metre per steradian [W m-2 sr -1];

EB

effective irradiance (blue light): calculated irradiance spectrally weighted by B (λ) expressed in watts per square metre [W m-2];

EIR

total irradiance (thermal injury): calculated irradiance within the infrared wavelength range 780 nm to 3 000  nm expressed in watts per square metre [W m-2];

Eskin

total irradiance (visible, IRA and IRB): calculated irradiance within the visible and infrared wavelength range 380 nm to 3 000  nm, expressed in watts per square metre [W m-2];

Hskin

radiant exposure: the time and wavelength integral or sum of the irradiance within the visible and infrared wavelength range 380 to 3 000  nm, expressed in joules per square metre (J m-2);

α

angular subtense: the angle subtended by an apparent source, as viewed at a point in space, expressed in milliradians (mrad). Apparent source is the real or virtual object that forms the smallest possible retinal image.



Table 1.1

Exposure limit values for non-coherent optical radiation

Index

Wavelength nm

Exposure limit value

Units

Comment

Part of the body

Hazard

a.

180-400

(UVA, UVB and UVC)

Heff = 30

Daily value 8 hours

[J m-2]

 



eye

cornea

conjunctiva

lens

skin

photokeratitis

conjunctivitis

cataractogenesis

erythema

elastosis

skin cancer

b.

315-400

(UVA)

HUVA = 104

Daily value 8 hours

[J m-2]

 

eye lens

cataractogenesis

c.

300-700

(Blue light) see note 1

image

for t ≤ 10 000  s

LB :[W m-2 sr-1]

t: [seconds]

for α ≥ 11 mrad

eye retina

photoretinitis

d.

300-700

(Blue light)

see note 1

LB = 100

for t > 10 000  s

[W m-2 sr-1]

e.

300-700

(Blue light)

see note 1

image

for t ≤ 10 000  s

EB: [W m-2]

t: [seconds]

for α < 11 mrad

see note 2

f.

300-700

(Blue light)

see note 1

EB = 0,01

t >10 000  s

[W m-2]

g.

380-1 400

(Visible and IRA)

image

for t >10 s

[W m-2 sr-1]

Cα = 1,7 for

α ≤ 1,7 mrad

Cα = α for

1,7 ≤ α ≤ 100 mrad

Cα = 100 for

α > 100 mrad

λ1= 380; λ2= 1 400

eye retina

retinal burn

h.

380-1 400

(Visible and IRA)

image

for 10 μs ≤ t ≤ 10 s

LR:[W m-2 sr-1]

t: [seconds]

i.

380-1 400

(Visible and IRA)

image

for t <10 μs

[W m-2 sr-1]

j.

780-1 400

(IRA)

image

for t > 10 s

[W m-2 sr-1]

Cα = 11 for

α ≤ 11 mrad

Cα = α for

11≤ α ≤ 100 mrad

Cα = 100 for

α > 100 mrad

(measurement field-of-view: 11 mrad)

λ1= 780; λ2= 1 400

eye retina

retinal burn

k.

780-1 400

(IRA)

image

for 10 μs ≤ t ≤ 10 s

LR: [W m-2 sr-1]

t: [seconds]

l.

780-1 400

(IRA)

image

for t < 10 μs

[W m-2 sr-1]

m.

780-3 000

(IRA and IRB)

EIR = 18 000  t-0,75

for t ≤ 1 000  s

E: [W m-2]

t: [seconds]

 



eye

cornea

lens

corneal burn

cataractogenesis

n.

780-3 000

(IRA and IRB)

EIR = 100

for t > 1 000  s

[W m-2]

o.

380-3 000

(Visible, IRA

and IRB)

Hskin = 20 000  t0,25

for t < 10 s

H: [J m-2]

t: [seconds]

 

skin

burn

Note 1: The range of 300 to 700 nm covers parts of UVB, all UVA and most of visible radiation; however, the associated hazard is commonly referred to as ‘blue light’ hazard. Blue light strictly speaking covers only the range of approximately 400 to 490 nm.

Note 2: For steady fixation of very small sources with an angular subtense < 11 mrad, LB can be converted to EB. This normally applies only for ophthalmic instruments or a stabilized eye during anaesthesia. The maximum ‘stare time’ is found by: tmax = 100/EB with EB expressed in W m-2. Due to eye movements during normal visual tasks this does not exceed 100 s.



Table 1.2

S (λ) [dimensionless], 180 nm to 400 nm

λ in nm

S (λ)

λ in nm

S (λ)

λ in nm

S (λ)

λ in nm

S (λ)

λ in nm

S (λ)

180

0,0120

228

0,1737

276

0,9434

324

0,000520

372

0,000086

181

0,0126

229

0,1819

277

0,9272

325

0,000500

373

0,000083

182

0,0132

230

0,1900

278

0,9112

326

0,000479

374

0,000080

183

0,0138

231

0,1995

279

0,8954

327

0,000459

375

0,000077

184

0,0144

232

0,2089

280

0,8800

328

0,000440

376

0,000074

185

0,0151

233

0,2188

281

0,8568

329

0,000425

377

0,000072

186

0,0158

234

0,2292

282

0,8342

330

0,000410

378

0,000069

187

0,0166

235

0,2400

283

0,8122

331

0,000396

379

0,000066

188

0,0173

236

0,2510

284

0,7908

332

0,000383

380

0,000064

189

0,0181

237

0,2624

285

0,7700

333

0,000370

381

0,000062

190

0,0190

238

0,2744

286

0,7420

334

0,000355

382

0,000059

191

0,0199

239

0,2869

287

0,7151

335

0,000340

383

0,000057

192

0,0208

240

0,3000

288

0,6891

336

0,000327

384

0,000055

193

0,0218

241

0,3111

289

0,6641

337

0,000315

385

0,000053

194

0,0228

242

0,3227

290

0,6400

338

0,000303

386

0,000051

195

0,0239

243

0,3347

291

0,6186

339

0,000291

387

0,000049

196

0,0250

244

0,3471

292

0,5980

340

0,000280

388

0,000047

197

0,0262

245

0,3600

293

0,5780

341

0,000271

389

0,000046

198

0,0274

246

0,3730

294

0,5587

342

0,000263

390

0,000044

199

0,0287

247

0,3865

295

0,5400

343

0,000255

391

0,000042

200

0,0300

248

0,4005

296

0,4984

344

0,000248

392

0,000041

201

0,0334

249

0,4150

297

0,4600

345

0,000240

393

0,000039

202

0,0371

250

0,4300

298

0,3989

346

0,000231

394

0,000037

203

0,0412

251

0,4465

299

0,3459

347

0,000223

395

0,000036

204

0,0459

252

0,4637

300

0,3000

348

0,000215

396

0,000035

205

0,0510

253

0,4815

301

0,2210

349

0,000207

397

0,000033

206

0,0551

254

0,5000

302

0,1629

350

0,000200

398

0,000032

207

0,0595

255

0,5200

303

0,1200

351

0,000191

399

0,000031

208

0,0643

256

0,5437

304

0,0849

352

0,000183

400

0,000030

209

0,0694

257

0,5685

305

0,0600

353

0,000175

 

 

210

0,0750

258

0,5945

306

0,0454

354

0,000167

 

 

211

0,0786

259

0,6216

307

0,0344

355

0,000160

 

 

212

0,0824

260

0,6500

308

0,0260

356

0,000153

 

 

213

0,0864

261

0,6792

309

0,0197

357

0,000147

 

 

214

0,0906

262

0,7098

310

0,0150

358

0,000141

 

 

215

0,0950

263

0,7417

311

0,0111

359

0,000136

 

 

216

0,0995

264

0,7751

312

0,0081

360

0,000130

 

 

217

0,1043

265

0,8100

313

0,0060

361

0,000126

 

 

218

0,1093

266

0,8449

314

0,0042

362

0,000122

 

 

219

0,1145

267

0,8812

315

0,0030

363

0,000118

 

 

220

0,1200

268

0,9192

316

0,0024

364

0,000114

 

 

221

0,1257

269

0,9587

317

0,0020

365

0,000110

 

 

222

0,1316

270

1,0000

318

0,0016

366

0,000106

 

 

223

0,1378

271

0,9919

319

0,0012

367

0,000103

 

 

224

0,1444

272

0,9838

320

0,0010

368

0,000099

 

 

225

0,1500

273

0,9758

321

0,000819

369

0,000096

 

 

226

0,1583

274

0,9679

322

0,000670

370

0,000093

 

 

227

0,1658

275

0,9600

323

0,000540

371

0,000090

 

 



Table 1.3

B (λ), R (λ) [dimensionless], 380 nm to 1 400  nm

λ in nm

B (λ)

R (λ)

300 ≤ λ < 380

0,01

380

0,01

0,1

385

0,013

0,13

390

0,025

0,25

395

0,05

0,5

400

0,1

1

405

0,2

2

410

0,4

4

415

0,8

8

420

0,9

9

425

0,95

9,5

430

0,98

9,8

435

1

10

440

1

10

445

0,97

9,7

450

0,94

9,4

455

0,9

9

460

0,8

8

465

0,7

7

470

0,62

6,2

475

0,55

5,5

480

0,45

4,5

485

0,32

3,2

490

0,22

2,2

495

0,16

1,6

500

0,1

1

500 < λ ≤ 600

100,02 ·(450 - λ)

1

600 < λ ≤ 700

0,001

1

700 < λ ≤ 1 050

100,002 · (700 - λ)

1 050 < λ ≤ 1 150

0,2

1 150 < λ ≤ 1 200

0,2 · 100,02 ·(1 150 - λ)

1 200 < λ ≤ 1 400

0,02




ANNEX II

Laser optical radiation

The biophysically relevant exposure values to optical radiation can be determined with the formulae below. The formulae to be used depend on the wavelength and duration of radiation emitted by the source and the results should be compared with the corresponding exposure limit values indicated in the Tables 2.2 to 2.4. More than one exposure value and corresponding exposure limit can be relevant for a given source of laser optical radiation.

Coefficients used as calculation tools within the Tables 2.2 to 2.4 are listed in Table 2.5 and corrections for repetitive exposure are listed in Table 2.6.

image

image

Notes:

dP

power expressed in watt [W];

dA

surface expressed in square metres [m2];

E (t), E

irradiance or power density: the radiant power incident per unit area upon a surface, generally expressed in watts per square metre [W m-2]. Values of E(t), E come from measurements or may be provided by the manufacturer of the equipment;

H

radiant exposure: the time integral of the irradiance, expressed in joules per square metre [J m-2];

t

time, duration of the exposure, expressed in seconds [s];

λ

wavelength, expressed in nanometres [nm];

γ

limiting cone angle of measurement field-of-view expressed in milliradians [mrad];

γm

measurement field of view expressed in milliradians [mrad];

α

angular subtense of a source expressed in milliradians [mrad];

limiting aperture: the circular area over which irradiance and radiant exposure are averaged;

G

integrated radiance: the integral of the radiance over a given exposure time expressed as radiant energy per unit area of a radiating surface per unit solid angle of emission, in joules per square metre per steradian [J m-2 sr -1].

Table 2.1

Radiation hazards



Wavelength [nm]

λ

Radiation range

Affected organ

Hazard

Exposure limit value table

180 to 400

UV

eye

photochemical damage and thermal damage

2.2, 2.3

180 to 400

UV

skin

erythema

2.4

400 to 700

visible

eye

retinal damage

2.2

400 to 600

visible

eye

photochemical damage

2.3

400 to 700

visible

skin

thermal damage

2.4

700 to 1 400

IRA

eye

thermal damage

2.2, 2.3

700 to 1 400

IRA

skin

thermal damage

2.4

1 400 to 2 600

IRB

eye

thermal damage

2.2

2 600 to 106

IRC

eye

thermal damage

2.2

1 400 to 106

IRB, IRC

eye

thermal damage

2.3

1 400 to 106

IRB, IRC

skin

thermal damage

2.4

Table 2.2

Exposure limit values for laser exposure to the eye — Short exposure duration < 10 s

image

Table 2.3

Exposure limit values for laser exposure to the eye — Long exposure duration ≥ 10 s

image

Table 2.4

Exposure limit values for laser exposure of skin

image

Table 2.5

Applied correction factors and other calculation parameters



Parameter as listed in ICNIRP

Valid spectral range (nm)

Value

CA

λ < 700

CA = 1,0

700 — 1 050

CA = 10 0,002 (λ - 700)

1 050 — 1 400

CA = 5,0

CB

400 — 450

CB = 1,0

450 — 700

CB = 10 0,02 (λ - 450)

CC

700 — 1 150

CC = 1,0

1 150 — 1 200

CC = 10 0,018 (λ - 1 150 )

1 200 — 1 400

CC = 8,0

T1

λ < 450

T1 = 10 s

450 — 500

T1 = 10 · [10 0,02 (λ - 450)] s

λ > 500

T1 = 100 s



Parameter as listed in ICNIRP

Valid for biological effect

Value

αmin

all thermal effects

αmin = 1,5 mrad



Parameter as listed in ICNIRP

Valid angular range (mrad)

Value

CE

α < αmin

CE = 1,0

αmin < α < 100

CE = α/αmin

α > 100

CE = α2/(αmin · αmax) mrad with αmax = 100 mrad

T2

α < 1,5

T2 = 10 s

1,5 < α < 100

T2 = 10 · [10 (α - 1,5 ) / 98,5 ] s

α > 100

T2 = 100 s



Parameter as listed in ICNIRP

Valid exposure time range (s)

Value

γ

t ≤ 100

γ = 11 [mrad]

100 < t < 104

γ = 1,1  t 0,5 [mrad]

t > 104

γ = 110 [mrad]

Table 2.6

Correction for repetitive exposure

Each of the following three general rules should be applied to all repetitive exposures as occur from repetitively pulsed or scanning laser systems:

1. The exposure from any single pulse in a train of pulses shall not exceed the exposure limit value for a single pulse of that pulse duration.

2. The exposure from any group of pulses (or sub-group of pulses in a train) delivered in time t shall not exceed the exposure limit value for time t.

3. The exposure from any single pulse within a group of pulses shall not exceed the single-pulse exposure limit value multiplied by a cumulative-thermal correction factor Cp=N-0,25 , where N is the number of pulses. This rule applies only to exposure limits to protect against thermal injury, where all pulses delivered in less than Tmin are treated as a single pulse.



Parameter

Valid spectral range (nm)

Value

Tmin

315 < λ ≤ 400

Tmin = 10 -9 s (= 1 ns)

400 < λ ≤ 1 050

Tmin = 18· 10 -6 s (= 18 μs)

1 050 < λ ≤ 1 400

Tmin = 50· 10 -6 s (= 50 μs)

1 400 < λ ≤ 1 500

Tmin = 10 -3 s (= 1 ms)

1 500 < λ ≤ 1 800

Tmin = 10 s

1 800 < λ ≤ 2 600

Tmin = 10 -3 s (= 1 ms)

2 600 < λ ≤ 10 6

Tmin = 10 -7 s (= 100 ns)



( 1 ) OJ L 245, 26.8.1992, p. 23.

( 2 ) OJ L 123, 12.5.2016, p. 1.

Top