Choose the experimental features you want to try

This document is an excerpt from the EUR-Lex website

Document 32010R0347

    Commission Regulation (EU) No 347/2010 of 21 April 2010 amending Commission Regulation (EC) No 245/2009 as regards the ecodesign requirements for fluorescent lamps without integrated ballast, for high intensity discharge lamps, and for ballasts and luminaires able to operate such lamps (Text with EEA relevance)

    OJ L 104, 24.4.2010, p. 20–28 (BG, ES, CS, DA, DE, ET, EL, EN, FR, IT, LV, LT, HU, MT, NL, PL, PT, RO, SK, SL, FI, SV)

    Legal status of the document No longer in force, Date of end of validity: 31/08/2021; Implicitly repealed by 32019R2020

    ELI: http://data.europa.eu/eli/reg/2010/347/oj

    24.4.2010   

    EN

    Official Journal of the European Union

    L 104/20


    COMMISSION REGULATION (EU) No 347/2010

    of 21 April 2010

    amending Commission Regulation (EC) No 245/2009 as regards the ecodesign requirements for fluorescent lamps without integrated ballast, for high intensity discharge lamps, and for ballasts and luminaires able to operate such lamps

    (Text with EEA relevance)

    THE EUROPEAN COMMISSION,

    Having regard to the Treaty on the Functioning of the European Union,

    Having regard to Directive 2009/125/EC of the European Parliament and of the Council of 21 October 2009 establishing a framework for the setting of ecodesign requirements for energy-related products (1), and in particular Article 15(1) thereof,

    After consulting the Ecodesign Consultation Forum,

    Whereas:

    (1)

    After the adoption of Commission Regulation (EC) No 245/2009 of 18 March 2009 implementing Directive 2005/32/EC of the European Parliament and of the Council with regard to ecodesign requirements for fluorescent lamps without integrated ballast, for high intensity discharge lamps, and for ballasts and luminaires able to operate such lamps, and repealing Directive 2000/55/EC of the European Parliament and of the Council (2), it appeared that certain provisions of that Regulation should be amended in order to avoid unintended impacts on the availability and performance of the products covered by that Regulation.

    (2)

    In addition, it is necessary to improve coherence, as regards the requirements on product information, between on the one hand Regulation (EC) No 245/2009 and on the other hand Commission Regulation (EC) No 244/2009 of 18 March 2009 implementing Directive 2005/32/EC of the European Parliament and of the Council with regard to ecodesign requirements for non-directional household lamps (3).

    (3)

    The measures provided for in this Regulation are in accordance with the opinion of the Committee established by Article 19(1) of Directive 2009/125/EC,

    HAS ADOPTED THIS REGULATION:

    Article 1

    Amendments to Regulation (EC) No 245/2009

    Annexes I, II, III and IV to Regulation (EC) No 245/2009 are amended as set out in the Annex to this Regulation.

    Article 2

    Entry into force

    This Regulation shall enter into force on the first day following its publication in the Official Journal of the European Union.

    It shall apply from 13 April 2010.

    This Regulation shall be binding in its entirety and directly applicable in all Member States.

    Done at Brussels, 21 April 2010.

    For the Commission

    The President

    José Manuel BARROSO


    (1)   OJ L 285, 31.10.2009, p. 10.

    (2)   OJ L 76, 24.3.2009, p. 17.

    (3)   OJ L 76, 24.3.2009, p. 3.


    ANNEX

    Amendments in Annexes I, II, III and IV to Regulation (EC) No 245/2009

    Annexes I, II, III and IV to Regulation (EC) No 245/2009 are amended as follows:

    1.

    Annex I is amended as follows:

    (a)

    the title is replaced by the following:

    ‘Exemptions’;

    (b)

    the introductory sentence in point 1 is replaced by the following:

    ‘The following lamps shall be exempt from the provisions of Annex III, provided that the technical documentation file drawn up for the purposes of conformity assessment pursuant to Article 8 of Directive 2009/125/EC states which of the technical parameters listed hereunder provide(s) a basis for their exemption:’;

    (c)

    points 1(c) and 1(d) are replaced by the following:

    ‘(c)

    blended high intensity discharge lamps having:

    6 % or more of total radiation of the range 250-780 nm in the range of 250-400 nm; and

    11 % or more of total radiation of the range 250-780 nm in the range of 630-780 nm; and

    5 % or more of total radiation of the range 250-780 nm in the range of 640-700 nm;

    (d)

    blended high intensity discharge lamps having:

    the peak of the radiation between 315-400 nm (UVA) or 280-315 nm (UVB);’;

    (d)

    point 2 is replaced by the following:

    ‘2.

    The following products shall be exempt from the provisions of Annex III, provided that in all forms of product information it is stated that they are not intended for general lighting use within the meaning of this Regulation, or that they are intended for use in applications listed in points (b) to (e):

    (a)

    products intended for use in applications other than general lighting and products incorporated into products which do not provide a general lighting function;

    (b)

    lamps covered by the requirements of Directives 94/9/EC of the European Parliament and of the Council (1) or Directive 1999/92/EC of the European Parliament and of the Council (2);

    (c)

    emergency lighting luminaires and emergency sign luminaires within the meaning of Directive 2006/95/EC of the European Parliament and of the Council (3).

    (d)

    ballasts intended for use in luminaires defined in paragraph (c) and designed to operate lamps in emergency conditions;

    (e)

    luminaires covered by the requirements of Directive 94/9/EC, Directive 1999/92/EC, Directive 2006/42/EC of the European Parliament and of the Council (4), Council Directive 93/42/EEC (5), Council Directive 88/378/EEC (6) and luminaires integrated into equipment covered by these requirements.

    The intended purpose shall be stated for each product in the product information, and the technical documentation file drawn up for the purposes of conformity assessment pursuant to Article 8 of Directive 2009/125/EC shall list the technical parameters that make the product design specific for the stated intended purpose.

    (1)   OJ L 100, 19.4.1994, p. 1."

    (2)   OJ L 23, 28.1.2000, p. 57."

    (3)   OJ L 374, 27.12.2006, p. 10."

    (4)   OJ L 157, 9.6.2006, p. 24."

    (5)   OJ L 169, 12.7.1993, p. 1."

    (6)   OL L 187, 16.7.1988, p. 1.’ "

    2.

    Annex II is amended as follows:

    (a)

    the first sentence is deleted;

    (b)

    The following sentence is added to point 1(c):

    ‘For the purposes of Table 6 in Annex III, the LSF shall be measured in high frequency operating mode with a switching cycle of 11h/1h.’

    (c)

    The following point (o) is added to point 3:

    ‘(o)

    “Blended lamp” means a lamp containing a mercury vapour lamp and an incandescent lamp filament connected in series in the same bulb.’

    3.

    Annex III is amended as follows:

    (a)

    The following paragraph is added before Table 1:

    ‘Spiral-shaped double capped fluorescent lamps of all diameters equal to or larger than 16 mm (T5) shall comply with the requirements set out in Table 5 for T9 circular lamps.’

    (b)

    Table 2 is replaced by the following:

    Table 2

    Rated minimum efficacy values for single capped fluorescent lamps working on electromagnetic and electronic ballast

    Small single parallel tube, lamp cap G23 (2 pin) or 2G7 (4 pin)

    Image 1
    Image 2

    Double parallel tubes, lamp cap G24d (2 pin) or G24q (4 pin)

    Image 3
    Image 4

    Triple parallel tubes, lamp cap GX24d (2 pin) or GX24q (4 pin)

    Image 5
    Image 6

    Nominal wattage

    (W)

    Rated luminous efficacy (lm/W), 100 h initial value

    Nominal wattage

    (W)

    Rated luminous efficacy (lm/W), 100 h initial value

    Nominal wattage

    (W)

    Rated luminous efficacy (lm/W), 100 h initial value

    5

    48

    10

    60

    13

    62

    7

    57

    13

    69

    18

    67

    9

    67

    18

    67

    26

    66

    11

    76

    26

    66

     

    4 legs in one plane, lamp cap 2G10

    (4 pin)

    Image 7

    Long single parallel tube, lamp cap 2G11

    (4 pin)

    Image 8
    Image 9

     

    Nominal wattage

    (W)

    Rated luminous efficacy (lm/W), 100 h initial value

    Nominal wattage

    (W)

    Rated luminous efficacy (lm/W), 100 h initial value

     

    18

    61

    18

    67

     

    24

    71

    24

    75

    36

    78

    34

    82

     

    36

    81 ’

    (c)

    Table 3 is replaced by the following:

    ‘Table 3

    Rated minimum efficacy values for single capped fluorescent lamps, working only on electronic ballast

    Triple parallel tubes, lamp cap GX24q

    (4 pin)

    Image 10

    Four parallel tubes, lamp cap GX24q

    (4 pin)

    Image 11

    Long single parallel tube, lamp cap 2G11

    (4 pin)

    Image 12
    Image 13

    Nominal wattage

    (W)

    Rated luminous efficacy (lm/W), 100 h initial value

    Nominal wattage

    (W)

    Rated luminous efficacy (lm/W), 100 h initial value

    Nominal wattage

    (W)

    Rated luminous efficacy (lm/W), 100 h initial value

    32

    75

    57

    75

    40

    83

    42

    74

    70

    74

    55

    82

    57

    75

     

    80

    75

    70

    74 ’

     

    (d)

    Table 6 is replaced by the following:

    Table 6

    Deduction percentages for rated minimum efficacy values for fluorescent lamps with high colour temperature and/or high colour rendering and/or second lamp envelope and/or long life

    Lamp parameter

    Deduction from luminous efficacy at 25 °C

    Tc ≥ 5 000  K

    –10  %

    95 ≥ Ra > 90

    –20  %

    Ra > 95

    –30  %

    Second lamp envelope

    –10  %

    Lamp Survival Factor ≥ 0,50 after 40 000 burning hours

    –5  %’

    (e)

    In Annex III.1.1.B, the sentence

    ‘The corrections defined for the first stage (Table 6) shall continue to apply’

    is replaced by

    ‘The corrections (Table 6) and the specific requirements for spiral-shaped double capped fluorescent lamps defined for the first stage shall continue to apply.’;

    (f)

    The title of Table 7 is replaced by the following:

    Table 7

    Rated minimum efficacy values for high pressure sodium lamps with Ra ≤ 60 ’;

    (g)

    The title of Table 8 is replaced by the following:

    Table 8

    Rated minimum efficacy values for Metal Halide Lamps with Ra ≤ 80 and for high pressure sodium lamps with Ra > 60

    (h)

    The second paragraph of Annex III.1.1.C is replaced by the following:

    ‘Fluorescent lamps without integrated ballast shall be able to operate with ballasts of energy efficiency class A2 or more efficient ballasts in accordance with point 2.2 of Annex III. In addition they may also operate with ballasts of less efficient classes than A2.’

    (i)

    Table 11 is replaced by the following:

    Table 11

    Lamp lumen maintenance factors for single and double capped fluorescent lamps — Stage 2

    Lamp lumen maintenance factor

    Burning hours

    Lamp types

    2 000

    4 000

    8 000

    16 000

    Double-Capped Fluorescent lamps operating on non-high frequency ballasts

    0,95

    0,92

    0,90

    T8 Double-Capped Fluorescent lamps on high frequency ballast with warmstart

    0,96

    0,92

    0,91

    0,90

    Other Double-Capped Fluorescent lamps on high frequency ballast with warmstart

    0,95

    0,92

    0,90

    0,90

    Circular Single-Capped Fluorescent lamps operating on non-high frequency ballasts, T8 U-shaped double-capped fluorescent lamps and spiral-shaped double capped fluorescent lamps of all diameters equal to or larger than 16 mm (T5)

    0,80

    0,74

    0,72 at 5 000 burning hours

    Circular Single-Capped Fluorescent lamps operating on high frequency ballasts

    0,85

    0,83

    0,80

    0,75 at 12 000 burning hours

    Other Single-Capped Fluorescent lamps operating on non-high frequency ballasts

    0,85

    0,78

    0,75

    Other Single-Capped Fluorescent lamps on high frequency ballast with warmstart

    0,90

    0,84

    0,81

    0,78 ’

    (j)

    The following introductory phrase and Table 11a is added after Table 11:

    ‘The following cumulative deductions shall be applied to the values in Table 11:

    Table 11a

    Deduction percentages for fluorescent lamp lumen maintenance requirements

    Lamp parameter

    Deduction from lamp lumen maintenance requirement

    Lamps with 95 ≥ Ra > 90

    At burning hours ≤ 8 000 h: – 5 %

    At burning hours > 8 000 h: – 10 %

    Lamps with Ra > 95

    At burning hours ≤ 4 000 h: – 10 %

    At burning hours > 4 000 h: – 15 %

    Lamps with a colour temperature ≥ 5 000 K

    –10  %’

    (k)

    Table 12 is replaced by the following:

    Table 12

    Lamp survival factors for single and double capped fluorescent lamps — Stage 2

    Lamp survival factor

    Burning hours

    Lamp types

    2 000

    4 000

    8 000

    16 000

    Double-Capped Fluorescent lamps operating on non-high frequency ballasts

    0,99

    0,97

    0,90

    Double-Capped Fluorescent lamps on high frequency ballast with warmstart

    0,99

    0,97

    0,92

    0,90

    Circular Single-Capped Fluorescent lamps operating on non-high frequency ballasts, T8 U-shaped double-capped fluorescent lamps and spiral-shaped double capped fluorescent lamps of all diameters equal to or larger than 16 mm (T5)

    0,98

    0,77

    0,50 at 5 000 burning hours

    Circular Single-Capped Fluorescent lamps operating on high frequency ballasts

    0,99

    0,97

    0,85

    0,50 at 12 000 burning hours

    Other Single-Capped Fluorescent lamps operating on non-high frequency ballasts

    0,98

    0,90

    0,50

    Other Single-Capped Fluorescent lamps on high frequency ballast with warmstart

    0,99

    0,98

    0,88

    —’

    (l)

    Table 13 is replaced by the following:

    Table 13

    Lamp lumen maintenance factors and lamp survival factors for high pressure sodium lamps — Stage 2

    High pressure sodium lamp category and burning hours for measurement

    Lamp lumen maintenance factor

    Lamp survival factor

    P ≤ 75 W

    LLMF and LSF measured at 12 000 burning hours

    Ra ≤ 60

    > 0,80

    > 0,90

    Ra > 60

    > 0,75

    > 0,75

    all retrofit lamps designed to operate on high pressure mercury vapour lamp ballast

    > 0,75

    > 0,80

    P > 75 W

    LLMF and LSF measured at 16 000 burning hours

    Ra ≤ 60

    > 0,85

    > 0,90

    Ra > 60

    > 0,70

    > 0,65

    all retrofit lamps designed to operate on high pressure mercury vapour lamp ballast

    > 0,75

    > 0,55

    The requirements in Table 13 for retrofit lamps designed to operate on high pressure mercury vapour lamp ballast shall be applicable until 6 years after the entry into force of this Regulation.’;

    (m)

    Annex III.1.3(i) is replaced by the following:

    ‘(i)

    Ambient temperature inside the luminaire at which the lamp was designed to maximise its luminous flux. If this temperature is equal to or lower than 0 °C or equal to or higher than 50 °C, it shall be stated that the lamp is not suitable for indoor use at standard room temperatures.’;

    (n)

    The following point (j) is added to point 1.3 of Annex III:

    ‘(j)

    For fluorescent lamps without integrated ballast, the energy efficiency index(es) of ballasts as defined in Table 17 with which the lamp can operate.’;

    (o)

    Table 17 is replaced by the following:

    Table 17

    Energy efficiency index requirements for non-dimmable ballasts for fluorescent lamps

    LAMP DATA

    BALLAST EFFICIENCY (Plamp/Pinput)

    Non-dimmable

    Lamp type

    Nominal Wattage

    ILCOS CODE

    Rated/typical wattage

    A2 BAT

    A2

    A3

    B1

    B2

    50  Hz

    HF

    W

    W

    W

     

     

     

     

     

    T8

    15

    FD-15-E-G13-26/450

    15

    13,5

    87,8  %

    84,4  %

    75,0  %

    67,9  %

    62,0  %

    T8

    18

    FD-18-E-G13-26/600

    18

    16

    87,7  %

    84,2  %

    76,2  %

    71,3  %

    65,8  %

    T8

    30

    FD-30-E-G13-26/900

    30

    24

    82,1  %

    77,4  %

    72,7  %

    79,2  %

    75,0  %

    T8

    36

    FD-36-E-G13-26/1200

    36

    32

    91,4  %

    88,9  %

    84,2  %

    83,4  %

    79,5  %

    T8

    38

    FD-38-E-G13-26/1050

    38,5

    32

    87,7  %

    84,2  %

    80,0  %

    84,1  %

    80,4  %

    T8

    58

    FD-58-E-G13-26/1500

    58

    50

    93,0  %

    90,9  %

    84,7  %

    86,1  %

    82,2  %

    T8

    70

    FD-70-E-G13-26/1800

    69,5

    60

    90,9  %

    88,2  %

    83,3  %

    86,3  %

    83,1  %

    TC-L

    18

    FSD-18-E-2G11

    18

    16

    87,7  %

    84,2  %

    76,2  %

    71,3  %

    65,8  %

    TC-L

    24

    FSD-24-E-2G11

    24

    22

    90,7  %

    88,0  %

    81,5  %

    76,0  %

    71,3  %

    TC-L

    36

    FSD-36-E-2G11

    36

    32

    91,4  %

    88,9  %

    84,2  %

    83,4  %

    79,5  %

    TCF

    18

    FSS-18-E-2G10

    18

    16

    87,7  %

    84,2  %

    76,2  %

    71,3  %

    65,8  %

    TCF

    24

    FSS-24-E-2G10

    24

    22

    90,7  %

    88,0  %

    81,5  %

    76,0  %

    71,3  %

    TCF

    36

    FSS-36-E-2G10

    36

    32

    91,4  %

    88,9  %

    84,2  %

    83,4  %

    79,5  %

    TC-D / DE

    10

    FSQ-10-E-G24q=1

    FSQ-10-I-G24d=1

    10

    9,5

    89,4  %

    86,4  %

    73,1  %

    67,9  %

    59,4  %

    TC-D / DE

    13

    FSQ-13-E-G24q=1

    FSQ-13-I-G24d=1

    13

    12,5

    91,7  %

    89,3  %

    78,1  %

    72,6  %

    65,0  %

    TC-D / DE

    18

    FSQ-18-E-G24q=2

    FSQ-18-I-G24d=2

    18

    16,5

    89,8  %

    86,8  %

    78,6  %

    71,3  %

    65,8  %

    TC-D / DE

    26

    FSQ-26-E-G24q=3

    FSQ-26-I-G24d=3

    26

    24

    91,4  %

    88,9  %

    82,8  %

    77,2  %

    72,6  %

    TC-T / TE

    13

    FSM-13-E-GX24q=1

    FSM-13-I-GX24d=1

    13

    12,5

    91,7  %

    89,3  %

    78,1  %

    72,6  %

    65,0  %

    TC-T / TE

    18

    FSM-18-E-GX24q=2

    FSM-18-I-GX24d=2

    18

    16,5

    89,8  %

    86,8  %

    78,6  %

    71,3  %

    65,8  %

    TC-T / TC-TE

    26

    FSM-26-E-GX24q=3

    FSM-26-I-GX24d=3

    26,5

    24

    91,4  %

    88,9  %

    82,8  %

    77,5  %

    73,0  %

    TC-DD / DDE

    10

    FSS-10-E-GR10q

    FSS-10-L/P/H-GR10q

    10,5

    9,5

    86,4  %

    82,6  %

    70,4  %

    68,8  %

    60,5  %

    TC-DD / DDE

    16

    FSS-16-E-GR10q

    FSS-16-I-GR8

    FSS-16-L/P/H-GR10q

    16

    15

    87,0  %

    83,3  %

    75,0  %

    72,4  %

    66,1  %

    TC-DD / DDE

    21

    FSS-21-E-GR10q

    FSS-21-L/P/H-GR10q

    21

    19,5

    89,7  %

    86,7  %

    78,0  %

    73,9  %

    68,8  %

    TC-DD / DDE

    28

    FSS-28-E-GR10q

    FSS-28-I-GR8

    FSS-28-L/P/H-GR10q

    28

    24,5

    89,1  %

    86,0  %

    80,3  %

    78,2  %

    73,9  %

    TC-DD / DDE

    38

    FSS-38-E-GR10q

    FSS-38-L/P/H-GR10q

    38,5

    34,5

    92,0  %

    89,6  %

    85,2  %

    84,1  %

    80,4  %

    TC

    5

    FSD-5-I-G23

    FSD-5-E-2G7

    5,4

    5

    72,7  %

    66,7  %

    58,8  %

    49,3  %

    41,4  %

    TC

    7

    FSD-7-I-G23

    FSD-7-E-2G7

    7,1

    6,5

    77,6  %

    72,2  %

    65,0  %

    55,7  %

    47,8  %

    TC

    9

    FSD-9-I-G23

    FSD-9-E-2G7

    8,7

    8

    78,0  %

    72,7  %

    66,7  %

    60,3  %

    52,6  %

    TC

    11

    FSD-11-I-G23

    FSD-11-E-2G7

    11,8

    11

    83,0  %

    78,6  %

    73,3  %

    66,7  %

    59,6  %

    T5

    4

    FD-4-E-G5-16/150

    4,5

    3,6

    64,9  %

    58,1  %

    50,0  %

    45,0  %

    37,2  %

    T5

    6

    FD-6-E-G5-16/225

    6

    5,4

    71,3  %

    65,1  %

    58,1  %

    51,8  %

    43,8  %

    T5

    8

    FD-8-E-G5-16/300

    7,1

    7,5

    69,9  %

    63,6  %

    58,6  %

    48,9  %

    42,7  %

    T5

    13

    FD-13-E-G5-16/525

    13

    12,8

    84,2  %

    80,0  %

    75,3  %

    72,6  %

    65,0  %

    T9-C

    22

    FSC-22-E-G10q-29/200

    22

    19

    89,4  %

    86,4  %

    79,2  %

    74,6  %

    69,7  %

    T9-C

    32

    FSC-32-E-G10q-29/300

    32

    30

    88,9  %

    85,7  %

    81,1  %

    80,0  %

    76,0  %

    T9-C

    40

    FSC-40-E-G10q-29/400

    40

    32

    89,5  %

    86,5  %

    82,1  %

    82,6  %

    79,2  %

    T2

    6

    FDH-6-L/P-W4,3x8,5d-7/220

     

    5

    72,7  %

    66,7  %

    58,8  %

     

     

    T2

    8

    FDH-8-L/P-W4,3x8,5d-7/320

     

    7,8

    76,5  %

    70,9  %

    65,0  %

     

     

    T2

    11

    FDH-11-L/P-W4,3x8,5d-7/420

     

    10,8

    81,8  %

    77,1  %

    72,0  %

     

     

    T2

    13

    FDH-13-L/P-W4,3x8,5d-7/520

     

    13,3

    84,7  %

    80,6  %

    76,0  %

     

     

    T2

    21

    FDH-21-L/P-W4,3x8,5d-7/

     

    21

    88,9  %

    85,7  %

    79,2  %

     

     

    T2

    23

    FDH-23-L/P-W4,3x8,5d-7/

     

    23

    89,8  %

    86,8  %

    80,7  %

     

     

    T5-E

    14

    FDH-14-G5-L/P-16/550

     

    13,7

    84,7  %

    80,6  %

    72,1  %

     

     

    T5-E

    21

    FDH-21-G5-L/P-16/850

     

    20,7

    89,3  %

    86,3  %

    79,6  %

     

     

    T5-E

    24

    FDH-24-G5-L/P-16/550

     

    22,5

    89,6  %

    86,5  %

    80,4  %

     

     

    T5-E

    28

    FDH-28-G5-L/P-16/1150

     

    27,8

    89,8  %

    86,9  %

    81,8  %

     

     

    T5-E

    35

    FDH-35-G5-L/P-16/1450

     

    34,7

    91,5  %

    89,0  %

    82,6  %

     

     

    T5-E

    39

    FDH-39-G5-L/P-16/850

     

    38

    91,0  %

    88,4  %

    82,6  %

     

     

    T5-E

    49

    FDH-49-G5-L/P-16/1450

     

    49,3

    91,6  %

    89,2  %

    84,6  %

     

     

    T5-E

    54

    FDH-54-G5-L/P-16/1150

     

    53,8

    92,0  %

    89,7  %

    85,4  %

     

     

    T5-E

    80

    FDH-80-G5-L/P-16/1150

     

    80

    93,0  %

    90,9  %

    87,0  %

     

     

    T5-E

    95

    FDH-95-G5-L/P-16/1150

     

    95

    92,7  %

    90,5  %

    84,1  %

     

     

    T5-E

    120

    FDH-120-G5-L/P-16/1450

     

    120

    92,5  %

    90,2  %

    84,5  %

     

     

    T5-C

    22

    FSCH-22-L/P-2GX13-16/225

     

    22,3

    88,1  %

    84,8  %

    78,8  %

     

     

    T5-C

    40

    FSCH-40-L/P-2GX13-16/300

     

    39,9

    91,4  %

    88,9  %

    83,3  %

     

     

    T5-C

    55

    FSCH-55-L/P-2GX13-16/300

     

    55

    92,4  %

    90,2  %

    84,6  %

     

     

    T5-C

    60

    FSCH-60-L/P-2GX13-16/375

     

    60

    93,0  %

    90,9  %

    85,7  %

     

     

    TC-LE

    40

    FSDH-40-L/P-2G11

     

    40

    91,4  %

    88,9  %

    83,3  %

     

     

    TC-LE

    55

    FSDH-55-L/P-2G11

     

    55

    92,4  %

    90,2  %

    84,6  %

     

     

    TC-LE

    80

    FSDH-80-L/P-2G11

     

    80

    93,0  %

    90,9  %

    87,0  %

     

     

    TC-TE

    32

    FSMH-32-L/P-2GX24q=3

     

    32

    91,4  %

    88,9  %

    82,1  %

     

     

    TC-TE

    42

    FSMH-42-L/P-2GX24q=4

     

    43

    93,5  %

    91,5  %

    86,0  %

     

     

    TC-TE

    57

    FSM6H-57-L/P-2GX24q=5

    FSM8H-57-L/P-2GX24q=5

     

    56

    91,4  %

    88,9  %

    83,6  %

     

     

    TC-TE

    70

    FSM6H-70-L/P-2GX24q=6

    FSM8H-70-L/P-2GX24q=6

     

    70

    93,0  %

    90,9  %

    85,4  %

     

     

    TC-TE

    60

    FSM6H-60-L/P-2G8=1

     

    63

    92,3  %

    90,0  %

    84,0  %

     

     

    TC-TE

    62

    FSM8H-62-L/P-2G8=2

     

    62

    92,2  %

    89,9  %

    83,8  %

     

     

    TC-TE

    82

    FSM8H-82-L/P-2G8=2

     

    82

    92,4  %

    90,1  %

    83,7  %

     

     

    TC-TE

    85

    FSM6H-85-L/P-2G8=1

     

    87

    92,8  %

    90,6  %

    84,5  %

     

     

    TC-TE

    120

    FSM6H-120-L/P-2G8=1

    FSM8H-120-L/P-2G8=1

     

    122

    92,6  %

    90,4  %

    84,7  %

     

     

    TC-DD

    55

    FSSH-55-L/P-GRY10q3

     

    55

    92,4  %

    90,2  %

    84,6  %’

     

     

    4.

    The following paragraph is added after the first paragraph of Annex IV:

    ‘Member States authorities shall use reliable, accurate and reproducible measurement procedures, which take into account the generally recognised state of the art measurement methods, including methods set out in documents the reference numbers of which have been published for that purpose in the Official Journal of the European Union.’


    (1)   OJ L 100, 19.4.1994, p. 1.

    (2)   OJ L 23, 28.1.2000, p. 57.

    (3)   OJ L 374, 27.12.2006, p. 10.

    (4)   OJ L 157, 9.6.2006, p. 24.

    (5)   OJ L 169, 12.7.1993, p. 1.

    (6)   OL L 187, 16.7.1988, p. 1.’ ’


    Top