This document is an excerpt from the EUR-Lex website
Document 32026R1310
Commission Delegated Regulation (EU) 2026/1310 of 11 June 2026 supplementing Regulation (EU) 2024/3110 of the European Parliament and of the Council by establishing the applicable assessment and verification systems for product families and categories
Commission Delegated Regulation (EU) 2026/1310 of 11 June 2026 supplementing Regulation (EU) 2024/3110 of the European Parliament and of the Council by establishing the applicable assessment and verification systems for product families and categories
Commission Delegated Regulation (EU) 2026/1310 of 11 June 2026 supplementing Regulation (EU) 2024/3110 of the European Parliament and of the Council by establishing the applicable assessment and verification systems for product families and categories
C/2026/3835
OJ L, 2026/1310, 28.8.2026, ELI: http://data.europa.eu/eli/reg_del/2026/1310/oj (BG, ES, CS, DA, DE, ET, EL, EN, FR, GA, HR, IT, LV, LT, HU, MT, NL, PL, PT, RO, SK, SL, FI, SV)
In force
|
Official Journal |
EN L series |
|
2026/1310 |
28.8.2026 |
COMMISSION DELEGATED REGULATION (EU) 2026/1310
of 11 June 2026
supplementing Regulation (EU) 2024/3110 of the European Parliament and of the Council by establishing the applicable assessment and verification systems for product families and categories
(Text with EEA relevance)
THE EUROPEAN COMMISSION,
Having regard to the Treaty on the Functioning of the European Union,
Having regard to Regulation (EU) 2024/3110 of the European Parliament and of the Council of 27 November 2024 laying down harmonised rules for the marketing of construction products and repealing Regulation (EU) No 305/2011 (1), and in particular Article 10(2) thereof,
Whereas:
|
(1) |
Considering the assessment and verification systems established in Annex IX of Regulation (EU) 2024/3110 and taking into account that for each product family or product category, Regulation (EU) 2024/3110 requires the establishment of the assessment and verification systems in relation to their essential characteristics and conformity with product requirements, it is therefore necessary to establish which assessment and verification system applies to each product family and category before harmonised technical specifications establishing essential characteristics, harmonised technical specifications establishing product requirements, or European assessment documents become applicable. |
|
(2) |
In order to ensure continuity with the regulatory system established under Regulation (EU) No 305/2011 of the European Parliament and of the Council (2), the assessment and verification of constancy of performance systems set out under that Regulation should be taken into consideration for establishing the assessment and verification systems under Regulation (EU) 2024/3110 insofar as they consider the intended uses, the potential damage resulting from product deficiencies, the product’s sensitivity to performance variations under production conditions, the likelihood of errors during its manufacturing and the possibility of easily detecting manufacturing errors. The assessment and verification systems should be tailored to the respective product families or product categories and should minimise the burden on manufacturers, whilst ensuring a high level of protection of health and safety of persons and of the environment. |
|
(3) |
While this delegated act applies to all product families, further amendments may be required to take account of specific needs identified during the development of standardisation requests and EADs. |
|
(4) |
To reduce the burden on manufacturers benefiting from the implementation of simplified procedures established by Regulation (EU) 2024/3110, applicable to essential characteristics deemed to satisfy certain performance without testing or without further testing, assessment and verification system 4 should apply, regardless of the system normally required when deemed-to-satisfy provisions do not apply. |
|
(5) |
Some essential characteristics of a horizontal nature grouped in accordance with Annex X to Regulation (EU) 2024/3110 should be covered by assessment and verifications systems irrespective of the related product family and category. This approach should be implemented for the groups of essential characteristics ‘reaction to fire’, ‘external fire performance’, ‘release and content of dangerous substances’ and ‘environmental sustainability’. |
|
(6) |
In accordance with Article 10(2) of Regulation (EU) 2024/3110, different assessment and verification systems may be set out within the same product family or product category, depending on the specific essential characteristics or product requirements. Therefore, the applicable assessment and verification system should be indicated for each product category, taking into account the intended uses and any additional remarks necessary to ensure a correct interpretation of the technical content, |
HAS ADOPTED THIS REGULATION:
Article 1
1. The assessment and verification system laid down in Annex I to this Regulation shall apply to the essential characteristics of specific products which are deemed to achieve a certain level or class of performance without testing or calculation, or without further testing or calculation, in accordance with a delegated act adopted pursuant to Article 5(6) of Regulation (EU) 2024/3110, provided that the deemed-to-satisfy provision set out in that delegated act is applied.
2. The assessment and verification system referred to in paragraph 1 of this Article shall prevail where the same essential characteristic is also laid down in accordance with Articles 2 and 3 of this Regulation. Where the deemed-to-satisfy option referred to in paragraph 1 is not applied, the applicable assessment and verification system shall be the one laid down in Articles 2 and 3.
Article 2
1. The assessment and verification system applicable to some essential characteristics of a horizontal nature grouped in accordance with Annex X to Regulation (EU) 2024/3110 shall be the assessment and verification systems set out in Annex II to this Regulation.
2. The assessment and verification system set out in accordance with paragraph 1 of this Article shall prevail where the same essential characteristic is also laid down in accordance with Article 3.
Article 3
The assessment and verification system applicable to essential characteristics and product requirements for a specific product category, taking into consideration the intended uses and any additional remark required to properly interpret the technical content, shall be the assessment and verification systems laid down in Annex III to this Regulation.
Article 4
This Regulation shall enter into force on the twentieth day following that of its publication in the Official Journal of the European Union.
This Regulation shall be binding in its entirety and directly applicable in all Member States.
Done at Brussels, 11 June 2026.
For the Commission
The President
Ursula VON DER LEYEN
(1) OJ L, 2024/3110, 18.12.2024, ELI: http://data.europa.eu/eli/reg/2024/3110/oj.
(2) Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ L 88, 4.4.2011, p. 5, ELI: http://data.europa.eu/eli/reg/2011/305/oj).
ANNEX I
Assessment and verification systems in case deemed-to-satisfy provisions apply
Table
|
Row |
Product family |
Product category |
Intended uses |
Essential characteristics |
Assessment and verification system |
Additional remarks |
|
1 |
All |
All |
All |
Those covered by a delegated act laying down conditions under which a product is to be deemed to satisfy a certain level, threshold level or to qualify for a class of performance without testing / calculation, or without further testing / calculation |
4 |
Under the conditions established by the relevant delegated act |
ANNEX II
Assessment and verification systems for essential characteristics of a horizontal nature
Applicable assessment and verification systems not covered by Annex I.
Table
|
Row |
Product family |
Product category |
Intended uses |
Essential characteristics |
Assessment and verification system |
Additional remarks |
|
1 |
31 |
Power, control and communication cables |
Reaction to fire classes A, B, or C |
Reaction to fire |
1+ |
Including subclasses, if applicable |
|
2 |
All |
Products for which a clearly identifiable stage in the production process results in improved reaction to fire performance, excluding power, control, and communication cables |
Reaction to fire classes A, B, or C |
Reaction to fire, and propensity to undergo continuous smouldering |
1 |
Including classes applicable to specific product categories and subclasses, if applicable |
|
3 |
All |
Products for which a clearly identifiable stage in the production process results in improved reaction to fire performance |
Reaction to fire classes D, or E |
Reaction to fire, and propensity to undergo continuous smouldering |
3 |
Including classes applicable to specific product categories and subclasses, if applicable |
|
4 |
All |
Products for which there is not a clearly identifiable stage in their production process resulting in an improvement of the reaction to fire performance |
Reaction to fire classes A, B, C, D, or E |
Reaction to fire, and propensity to undergo continuous smouldering |
3 |
Including classes applicable to specific product categories and subclasses, if applicable |
|
5 |
All |
All |
Reaction to fire class F |
Reaction to fire, and propensity to undergo continuous smouldering |
4 |
Including classes applicable to specific product categories, if applicable |
|
6 |
All |
All |
Roofing and facades |
External fire performance |
3 |
Including roof windows, rooflights, and curtain walling |
|
7 |
All |
All |
Products in contact with soil and ground water |
Release of dangerous substances into soil and ground water |
2+ |
|
|
8 |
All |
All |
Products in contact with indoor air |
Emission of dangerous substances into indoor air |
3 |
|
|
9 |
All |
All |
All |
Content of dangerous substances |
2+ |
|
|
10 |
All |
All |
All |
Environmental sustainability |
3+ |
|
ANNEX III
Assessment and verification systems by product family and category
Applicable assessment and verification systems not covered by Annex I or Annex II.
Table
|
Row |
Product family |
Product category |
Intended uses |
Essential characteristics and product requirements |
Assessment and verification system |
Additional remarks |
|
1 |
1 |
Precast normal, lightweight and autoclaved aerated concrete products |
Structural use |
All |
2+ |
Including products incorporating non-mineral aggregates |
|
2 |
1 |
Precast normal, lightweight and autoclaved aerated concrete products |
Non-structural use and light structural use |
All |
4 |
Including products incorporating non-mineral aggregates |
|
3 |
2 |
Building hardware |
Fire and/or smoke compartmentation and escape routes |
All |
1 |
|
|
4 |
2 |
Building hardware |
Other than fire compartmentation, smoke compartmentation or escape routes |
All |
3 |
|
|
5 |
2 |
Gates and industrial, commercial and garage doors |
All |
Related to fire, smoke and evacuation in escape routes performance |
1 |
Including hardware |
|
6 |
2 |
Gates and industrial, commercial and garage doors |
All |
Non-related to fire, smoke or evacuation in escape routes performance |
3 |
Including hardware |
|
7 |
2 |
Shutters |
All except use as gates or doors |
Related to fire performance and smoke performance |
3 |
Including shutters in roof windows |
|
8 |
2 |
Shutters |
All except use as gates or doors |
Non-related to fire or smoke performance |
4 |
Including shutters in roof windows |
|
9 |
2 |
Blinds and awnings |
All |
All |
4 |
Including blinds in roof windows |
|
10 |
2 |
Windows and pedestrian doors with or without structural sealant glazing |
All |
Related to fire, smoke, evacuation in escape routes, anti-bullet and anti-explosion performance |
1 |
Including hardware |
|
11 |
2 |
Windows and pedestrian doors without structural sealant glazing |
All |
Non-related to fire, smoke, evacuation in escape routes, anti-bullet or anti-explosion performance |
3 |
Including hardware |
|
12 |
2 |
Windows and pedestrian doors with structural sealant glazing without devices to reduce the risk in case of sealant failure |
All |
Related to the risk of structural sealant failure performance |
1 |
|
|
13 |
2 |
Windows and pedestrian doors with structural sealant glazing with devices to reduce the risk in case of sealant failure |
All |
Related to the risk of structural sealant failure performance |
2+ |
|
|
14 |
2 |
Windows and pedestrian doors with structural sealant glazing |
All |
Non-related to fire, smoke, evacuation in escape routes, anti-bullet, anti-explosion or risk of structural sealant failure performance |
3 |
|
|
15 |
3 |
Coating products and kits |
Storage filling and handling of water endangering liquids |
All |
2+ |
Including the effect of eliminating electrostatic charges |
|
16 |
3 |
Damp proof courses |
All |
All |
3 |
|
|
17 |
3 |
Damp proofing sheets |
All |
All |
2+ |
|
|
18 |
3 |
Liquid applied water proofing kits |
Roofing |
All |
3 |
|
|
19 |
3 |
Liquid applied waterproofing kits |
All except roofing |
All |
2+ |
Including swimming pools |
|
20 |
3 |
Roof sheets |
All |
All |
2+ |
Including flexible roof sheets |
|
21 |
3 |
Roof underlays |
All |
All |
3 |
|
|
22 |
3 |
Surface water repellent products |
All |
All |
4 |
|
|
23 |
3 |
Water vapour control layers |
All |
All |
3 |
|
|
24 |
3 |
Watertight covering kits |
Wetroom floors and walls |
All |
2+ |
|
|
25 |
3 |
Roof waterproofing membranes kits |
All |
All |
2+ |
|
|
26 |
4 |
External thermal insulation composite kits |
External thermal insulation composite kits |
Related to the performance of the external thermal insulation composite kit |
1 |
AV system for essential characteristics related to components set out in the relevant row addressing them |
|
27 |
4 |
Thermal insulating products |
All |
All |
3 |
Including factory made and formed in-situ |
|
28 |
4 |
Cold storage kits |
All |
All |
1 |
Including building and envelope kits |
|
29 |
4 |
Veture kits |
All |
All |
1 |
|
|
30 |
4 |
Vibration and noise insulation products and kits |
All |
All |
3 |
Including impact noise insulation |
|
31 |
5 |
Pins for structural joints |
All |
All |
2+ |
Including dowels for structural joints under static and quasi-static loading |
|
32 |
5 |
Structural bearings |
Individual elements that are critical |
All |
1 |
Including sealing and sliding materials and products with a thermal break function |
|
33 |
5 |
Structural bearings |
Individual elements that are not critical |
All |
3 |
Including sealing and sliding materials and products with a thermal break function |
|
34 |
6 |
Chimney terminals |
Chimneys |
All |
4 |
|
|
35 |
6 |
Prefabricated chimneys |
Chimneys |
All |
2+ |
Including kits and ancillaries |
|
36 |
6 |
Ventilation ducts and pipes |
Air ventilation |
All |
3 |
Including pipe and duct supports and safety ancillaries |
|
37 |
7 |
Gypsum blocks |
All |
Related to fire performance |
3 |
Including ancillary products |
|
38 |
7 |
Gypsum blocks |
All |
Non-related to fire performance |
4 |
Including ancillary products |
|
39 |
7 |
Gypsum ceiling elements |
All |
Related to fire performance |
3 |
Including ancillary products |
|
40 |
7 |
Gypsum ceiling elements |
All |
Non-related to fire performance |
4 |
Including ancillary products |
|
41 |
7 |
Gypsum boards |
All |
Related to fire and structural performance |
3 |
Including fibre boards and ancillary products |
|
42 |
7 |
Gypsum boards |
All |
Non-related to fire or structural performance |
4 |
Including fibre boards and ancillary products |
|
43 |
7 |
Gypsum plasters |
All |
Related to fire performance |
3 |
Including ancillary products |
|
44 |
7 |
Gypsum plasters |
All |
Non-related to fire or structural performance |
4 |
Including ancillary products |
|
45 |
8 |
Geosynthetic barriers |
All |
All |
2+ |
Including mats |
|
46 |
8 |
Geotextiles and related products |
All |
All |
2+ |
Including mats |
|
47 |
9 |
Curtain walling kits, glass roofing kits, and frameless glass façade kits with or without structural sealant glazing |
All |
Related to fire, smoke, evacuation in escape routes, anti-bullet and anti-explosion performance |
1 |
|
|
48 |
9 |
Curtain walling kits, glass roofing kits, and frameless glass façade kits without structural sealant glazing |
All |
Non-related to fire, smoke, evacuation in escape routes, anti-bullet or anti-explosion performance |
3 |
|
|
49 |
9 |
Curtain walling kits, glass roofing kits, and frameless glass façade kits with structural sealant glazing without devices to reduce the risk in case of sealant failure |
All |
Related to the risk of structural sealant failure performance |
1 |
|
|
50 |
9 |
Curtain walling kits, glass roofing kits, and frameless glass façade kits with structural sealant glazing with devices to reduce the risk in case of sealant failure |
All |
Related to the risk of structural sealant failure performance |
2+ |
|
|
51 |
9 |
Curtain walling kits, glass roofing kits, and frameless glass façade kits with structural sealant glazing |
All |
Non-related to fire, smoke, evacuation in escape routes, anti-bullet, anti-explosion or risk of structural sealant failure performance |
3 |
|
|
52 |
9 |
Exterior wall cladding kits |
Walls and roofs |
All |
2+ |
|
|
53 |
10 |
Explosion suppression products |
Fire safety |
All |
1 |
Including kits, components and ancillaries |
|
54 |
10 |
Fire detection and/or alarm products |
Fire safety |
All |
1 |
Including kits, components and ancillaries |
|
55 |
10 |
Fire and smoke control products |
Fire safety |
Related to fire performance and smoke performance |
1 |
Including kits, components and ancillaries |
|
56 |
10 |
Fire and smoke control products |
Fire safety |
Non-related to fire performance and smoke performance |
3 |
Including kits, components and ancillaries – AV system applicable unless the AV system is set out by another product family |
|
57 |
10 |
Fire suppression and extinguishing products |
Fire safety |
All |
1 |
Including kits, components and ancillaries |
|
58 |
10 |
Fixed firefighting products |
Fire safety |
All |
1 |
Including kits, components and ancillaries |
|
59 |
11 |
Sanitary appliances |
Hygiene and contact with water |
All |
4 |
|
|
60 |
11 |
Sinks |
Contact with food and water |
All |
4 |
|
|
61 |
12 |
Anti-glare screens |
Vehicular and pedestrian traffic uses |
All |
3 |
|
|
62 |
12 |
Expansion joints |
Bridges |
All |
1 |
|
|
63 |
12 |
Pedestrian restraint systems |
Pedestrian traffic uses |
All |
1 |
Including pedestrian bridge parapets |
|
64 |
12 |
Lighting columns |
Vehicular and pedestrian traffic uses |
All |
1 |
|
|
65 |
12 |
Traffic noise reducing devices and barriers |
Vehicular and pedestrian traffic uses |
All |
3 |
|
|
66 |
12 |
Protective perimeter fencing products |
Vehicular and pedestrian traffic uses |
All |
3 |
Including kits |
|
67 |
12 |
Traffic signs |
Vehicular and pedestrian traffic uses |
All |
1 |
Including road studs and drop-on materials |
|
68 |
12 |
Traffic control devices |
Vehicular and pedestrian traffic uses |
All |
1 |
|
|
69 |
12 |
Vehicle restraint systems |
Vehicular traffic uses |
All |
1 |
|
|
70 |
12 |
Reusable foundation sockets for equipment installation |
Vehicular and pedestrian traffic uses |
All |
1 |
|
|
71 |
13 |
Fasteners for structural timber products other than plates |
Structural use |
All |
1 |
|
|
72 |
13 |
Fasteners plates for structural timber products |
Structural use |
All |
2+ |
|
|
73 |
13 |
Glued laminated timber and other glued timber products and kits |
Structural use |
All |
1 |
Including glued composite wood-based products and light beams and columns |
|
74 |
13 |
Solid timber products and kits |
Structural use |
All |
2+ |
|
|
75 |
13 |
Timber poles |
All |
All |
2+ |
|
|
76 |
14 |
Prefabricated wood-based loadbearing stressed skin panels |
All |
Related to fire and structural performance |
1 |
|
|
77 |
14 |
Prefabricated wood-based loadbearing stressed skin panels |
All |
Non-related to fire or structural performance |
4 |
|
|
78 |
14 |
Wood-based non-stressed skin panels |
Structural use |
All |
2+ |
|
|
79 |
14 |
Wood-based non-stressed skin panels |
Non-structural use |
All |
4 |
|
|
80 |
15 |
Building limes for construction |
All |
All |
2+ |
Including calcium, dolomitic and hydraulic lime |
|
81 |
15 |
Cement |
All |
Related to the constituents |
2+ |
Including common cement, calcium aluminate cements, masonry cement, supersulfated cement, very low heat cement and alkali activated cement |
|
82 |
15 |
Cement |
All |
Non-related to the constituents |
1+ |
Including common cement, calcium aluminate cements, masonry cement, supersulfated cement, very low heat cement and alkali activated cement |
|
83 |
15 |
Hydraulic road binders |
All |
All |
2+ |
|
|
84 |
16 |
Ducts and sheaths |
Protection and guide of prestressing steel products |
All |
4 |
|
|
85 |
16 |
Pile connectors and anchors |
Load bearing precast concrete piles |
All |
1 |
Including pile joints and rock shoes |
|
86 |
16 |
Post-tensioning kits |
Post-tensioning of concrete |
All |
1+ |
Including filling products |
|
87 |
16 |
Prestressing steel products |
Prestressing of concrete |
All |
1+ |
Including wires, strands, bars and cables |
|
88 |
16 |
Reinforcing non-steel products for concrete |
All |
All |
1+ |
Including bonded carbon fibre reinforced polymer strips |
|
89 |
16 |
Reinforcing steel products |
Reinforcement of concrete |
All |
1+ |
Including bars, rods, coils, welded fabrics, lattice girders, indented strips, couplers, sleeves, studs and connectors |
|
90 |
16 |
Steel reinforcement sheets |
Composite floor systems |
All |
2+ |
|
|
91 |
17 |
Masonry ancillary products |
All |
All |
3 |
Including ties, tension straps, joist hangers, brackets, support angles, bed joint reinforcements, lintels and wall plates |
|
92 |
17 |
Masonry factory made mortars |
Structural use |
All |
2+ |
|
|
93 |
17 |
Masonry factory made mortars |
Non-structural use |
All |
4 |
Including rendering and plastering |
|
94 |
17 |
Masonry units |
Structure designed with low safety factors |
All |
2+ |
Including units incorporating insulation materials and used units |
|
95 |
17 |
Masonry units |
Structure designed with high safety factors and non-structural |
All |
4 |
Including units incorporating insulation materials and used units |
|
96 |
17 |
Prefabricated cavity trays |
Masonry |
All |
3 |
|
|
97 |
17 |
Wall plates made of stainless steel |
Masonry |
All |
3 |
|
|
98 |
18 |
Air admittance valves for ventilating pipework |
Wastewater back-flow devices |
All |
4 |
|
|
99 |
18 |
Drainage channels |
All |
All |
3 |
Including fittings for drainage |
|
100 |
18 |
Effluent lifting plant kits |
All |
All |
3 |
|
|
101 |
18 |
Flood protection barriers |
All |
All |
2+ |
|
|
102 |
18 |
Kits and elements for wastewater treatment plants |
All |
All |
3 |
Including on-site treatment equipment |
|
103 |
18 |
Manhole and inspection chambers |
All |
All |
4 |
|
|
104 |
18 |
Manhole covers and gully tops |
Vehicular and pedestrian areas |
All |
1 |
|
|
105 |
18 |
Septic tanks |
All |
All |
3 |
|
|
106 |
18 |
Step irons, ladders and handrails |
Manholes and inspection chambers |
All |
4 |
|
|
107 |
18 |
Vacuum valves |
Sewage systems |
All |
4 |
|
|
108 |
18 |
Vertical centrifugal storm water flow regulator |
All |
All |
4 |
|
|
109 |
18 |
Wastewater and sewage separators |
All |
All |
4 |
|
|
110 |
18 |
Wastewater pumping station kits |
All |
All |
3 |
|
|
111 |
18 |
Wastewater trap kits |
All |
All |
4 |
Including trapped gully, removable, mechanical closure, waterless odour traps and flexible couplings |
|
112 |
18 |
Wastewater treatment plants |
All |
All |
3 |
Including kits and treatment equipment |
|
113 |
19 |
Floor screed products |
All |
Related to thermal, acoustic and impact performance |
3 |
|
|
114 |
19 |
Floor screed products |
All |
Non-related to thermal, acoustic or impact performance |
4 |
|
|
115 |
19 |
Flooring underlayers |
All |
Related to thermal, acoustic and impact performance |
3 |
Including mats |
|
116 |
19 |
Flooring underlayers |
All |
Non-related to thermal, acoustic or impact performance |
4 |
Including mats |
|
117 |
19 |
Flooring decking products |
All |
Related to safety in use performance |
2+ |
Including kits |
|
118 |
19 |
Flooring decking products |
All |
Non-related to safety in use performance |
4 |
Including kits |
|
119 |
19 |
Resilient, textile, laminate and modular mechanical floor coverings |
All |
All |
4 |
Including tiles, planks, rolls and sheets |
|
120 |
19 |
Rigid floor coverings |
All excluding raised floors without any supporting element for load bearing |
All |
4 |
Including tiles, mosaics, parquet, decking of mesh or sheet and gratings |
|
121 |
19 |
Rigid floor coverings |
Raised floors without any supporting element for load bearing |
Related to safety in use performance |
2+ |
|
|
122 |
19 |
Rigid floor coverings |
Raised floors without any supporting element for load bearing |
Non-related to safety in use performance |
4 |
|
|
123 |
19 |
Floorings for sports facilities |
All |
All |
4 |
|
|
124 |
20 |
Metallic connectors, components and kits |
Structural use |
All |
2+ |
Including rivets, bolting components bolting kits and fasteners including point fasteners and railway fasteners |
|
125 |
20 |
Metallic members |
Structural use excluding suspended heavy-duty ceilings |
All |
2+ |
Including trusses, girders, columns, stairs, piles, sheet piling, rails, sleepers and joints of these members |
|
126 |
20 |
Metallic members |
Structural use for suspended heavy-duty ceilings |
All |
1 |
Including framings |
|
127 |
20 |
Metallic meshes, gabions and mattresses |
Structural use |
All |
2+ |
|
|
128 |
20 |
Metallic sections and flat products |
Structural use |
All |
2+ |
Including profiles, bars, castings and forgings |
|
129 |
20 |
Metallic welding materials |
Structural use |
All |
2+ |
|
|
130 |
20 |
Metallic wires |
Structural use |
All |
2+ |
Including wire rings |
|
131 |
20 |
Protective products for metallic elements |
Structural use |
All |
2+ |
Including paints and tapes |
|
132 |
20 |
Spring elements for metallic structures |
Structural use |
All |
2+ |
|
|
133 |
20 |
Metallic profiled sheeting |
Structural use |
All |
2+ |
|
|
134 |
21 |
Internal partition kits |
All |
Related to structural performance |
2+ |
|
|
135 |
21 |
Internal partition kits |
All |
Related to fire and safety in use performance |
3 |
|
|
136 |
21 |
Internal partition kits |
All |
Non-related to structural, fire or safety in use performance |
4 |
|
|
137 |
21 |
Wall and ceiling finishes |
Non-structural |
Related to fire performance |
3 |
Including rolls, linings, tiles, slabs, and single-sheet panels |
|
138 |
21 |
Wall and ceiling finishes |
Non-structural |
Non-related to fire performance |
4 |
Including rolls, linings, tiles, slabs, and single-sheet panels |
|
139 |
22 |
Roof covering accessories |
Roof coverings |
All |
4 |
|
|
140 |
22 |
Anchor devices |
Prevent persons from falling from a height or to arrest falls from a height |
All |
1+ |
|
|
141 |
22 |
Fascias and soffit boards |
Roofings |
All |
4 |
Including eaves profiles for terraces and balconies |
|
142 |
22 |
Flat and profiled sheets for roofings |
All |
Related to fire and structural performance |
3 |
|
|
143 |
22 |
Flat and profiled sheets for roofings |
All |
Non-related to fire or structural performance |
4 |
|
|
144 |
22 |
Mastic asphalt for roofings |
Roofings |
All |
3 |
|
|
145 |
22 |
Mechanical fixings for roof coverings |
Non-structural |
All |
4 |
|
|
146 |
22 |
Roof access systems |
Roofings |
All |
3 |
Including walkways and footholds |
|
147 |
22 |
Roof paving |
All |
All |
4 |
|
|
148 |
22 |
Roof windows |
Roofings |
Related to fire performance and smoke performance |
1 |
|
|
149 |
22 |
Roof windows |
Roofings |
Non-related to fire or smoke performance |
3 |
|
|
150 |
22 |
Rooflights |
Roofings |
Related to fire performance and smoke performance |
1 |
Including self–supporting ridgelights and roof hatches |
|
151 |
22 |
Rooflights |
Roofings |
Non-related to fire or smoke performance |
3 |
Including self–supporting ridgelights and roof hatches |
|
152 |
22 |
Roofing tiles |
All |
Related to fire performance |
3 |
Including slates, stones and shingles |
|
153 |
22 |
Roofing tiles |
All |
Non-related to fire performance |
4 |
Including slates, stones and shingles |
|
154 |
22 |
Self-supporting translucent roof kits |
Roof coverings |
All |
3 |
Non-glass-based kits |
|
155 |
23 |
Additives for bituminous mixtures |
All |
All |
2+ |
|
|
156 |
23 |
Ancillary products for roads |
Concrete roads |
All |
4 |
Including joint fillers and sealants used in non-highly loaded concrete roads |
|
157 |
23 |
Joint fillers and sealants |
Highly loaded concrete roads |
All |
2+ |
|
|
158 |
23 |
Bitumen |
All |
All |
2+ |
|
|
159 |
23 |
Bituminous mixtures |
All |
All |
2+ |
|
|
160 |
23 |
Components for bituminous mixtures |
All |
All |
2+ |
Including crumb rubber powder |
|
161 |
23 |
Road marking products |
All |
All |
1 |
Including drop-on materials, tapes, preformed markings, paints and other mixtures |
|
162 |
23 |
Road surface treatments |
All |
All |
2+ |
|
|
163 |
23 |
Waterproofing products and kits |
Bridges |
All |
2+ |
|
|
164 |
24 |
Aggregates |
With high safety requirements |
All |
2+ |
Including use for concrete, mortar, grout, bituminous mixtures, surface treatments, unbound and hydraulically bound mixtures |
|
165 |
24 |
Aggregates |
Without high safety requirements |
All |
4 |
Including use for concrete, mortar, grout, bituminous mixtures, surface treatments, unbound and hydraulically bound mixtures |
|
166 |
24 |
Armourstones |
With high safety requirements |
All |
2+ |
|
|
167 |
24 |
Armourstones |
Without high safety requirements |
All |
4 |
|
|
168 |
24 |
Fillers |
With high safety requirements |
All |
2+ |
Including use for concrete, mortar, grout, bituminous mixtures and surface treatments |
|
169 |
24 |
Fillers |
Without high safety requirements |
All |
4 |
Including use for concrete, mortar, grout, bituminous mixtures and surface treatments |
|
170 |
24 |
Railway ballast |
With high safety requirements |
All |
2+ |
|
|
171 |
24 |
Railway ballast |
Without high safety requirements |
All |
4 |
|
|
172 |
25 |
Adhesives for tiles |
All |
All |
3 |
|
|
173 |
25 |
Structural adhesives |
Structural use |
All |
2+ |
|
|
174 |
26 |
Additions |
Inert and nearly inert |
All |
2+ |
|
|
175 |
26 |
Additions |
Pozzolanic or latent hydraulic |
All |
1+ |
|
|
176 |
26 |
Admixtures |
All |
All |
2+ |
Including elastic micro hollow spheres |
|
177 |
26 |
Ready-mixed concrete |
All |
All |
2+ |
|
|
178 |
26 |
Concrete protection and repair products and kits |
Repair of element with structural function |
All |
2+ |
Including protection, strengthening and repair of masonry |
|
179 |
26 |
Concrete protection and repair products and kits |
Repair of element without structural function |
All |
4 |
Including protection, strengthening and repair of masonry |
|
180 |
26 |
Fibres |
Concrete for structural use |
All |
1 |
Including fibre meshes |
|
181 |
26 |
Fibres |
Concrete for non-structural use |
All |
3 |
Including fibre meshes |
|
182 |
27 |
Space heating appliances |
In buildings |
All |
3 |
|
|
183 |
28 |
Adhesives and joints |
Not in contact with water intended for human consumption |
Related to energy conservation performance |
3 |
Including joint sealings and gaskets |
|
184 |
28 |
Adhesives and joints |
Not in contact with water intended for human consumption |
Non-related to energy conservation performance |
4 |
Including joint sealings and gaskets |
|
185 |
28 |
Protective ducts and conduits |
Not in contact with water intended for human consumption |
Related to fire performance |
1 |
|
|
186 |
28 |
Protective ducts and conduits |
Not in contact with water intended for human consumption |
Related to energy conservation performance |
3 |
|
|
187 |
28 |
Protective ducts and conduits |
Not in contact with water intended for human consumption |
Non-related to energy conservation performance |
4 |
|
|
188 |
28 |
Leakage alarm systems |
Not in contact with water intended for human consumption |
Related to energy conservation performance |
3 |
Including overfill prevention devices |
|
189 |
28 |
Leakage alarm systems |
Not in contact with water intended for human consumption |
Non-related to energy conservation performance |
4 |
Including overfill prevention devices |
|
190 |
28 |
Pipes |
Not in contact with water intended for human consumption |
Related to energy conservation performance |
3 |
Including piping kits and fittings |
|
191 |
28 |
Pipes |
Not in contact with water intended for human consumption |
Non-related to energy conservation performance |
4 |
Including piping kits and fittings |
|
192 |
28 |
Tanks |
Not in contact with water intended for human consumption |
Related to fire performance |
1 |
|
|
193 |
28 |
Tanks |
Not in contact with water intended for human consumption |
Related to energy conservation performance |
3 |
|
|
194 |
28 |
Tanks |
Not in contact with water intended for human consumption |
Non-related to fire or energy conservation performance |
4 |
|
|
195 |
28 |
Valves and taps |
Not in contact with water intended for human consumption |
Related to energy conservation performance |
3 |
|
|
196 |
28 |
Valves and taps |
Not in contact with water intended for human consumption |
Non-related to energy conservation performance |
4 |
|
|
197 |
29 |
Adhesives and joints |
In contact with water intended for human consumption |
All |
3 |
Including joint sealings and gaskets |
|
198 |
29 |
Ducts and conduits for protection |
In contact with water intended for human consumption |
All |
3 |
|
|
199 |
29 |
Leakage alarm systems |
In contact with water intended for human consumption |
All |
3 |
Including overfill prevention devices |
|
200 |
29 |
Pipes |
In contact with water intended for human consumption |
All |
3 |
Including piping kits and fittings |
|
201 |
29 |
Tanks |
In contact with water intended for human consumption |
All |
3 |
|
|
202 |
29 |
Valves and taps |
In contact with water intended for human consumption |
All |
3 |
|
|
203 |
30 |
Flat or curved glass |
All |
Related to fire, anti-bullet and anti-explosion performance |
1 |
Including channel-shaped glass and insulating glass units |
|
204 |
30 |
Flat or curved glass |
All |
Related to safety in use, energy conservation and direct airborne sound insulation performance |
3 |
Including channel-shaped glass and insulating glass units |
|
205 |
30 |
Flat or curved glass |
All |
Non-related to fire, anti-bullet and anti-explosion, safety in use, energy conservation or direct airborne sound insulation performance |
4 |
Including channel-shaped glass and insulating glass units |
|
206 |
30 |
Glass-blocks |
All |
Related to fire, anti-bullet and anti-explosion performance |
1 |
Including glass-block wall panels |
|
207 |
30 |
Glass-blocks |
All |
Related to safety in use, energy conservation and direct airborne sound insulation performance |
3 |
Including glass-block wall panels |
|
208 |
30 |
Glass-blocks |
All |
Non-related to fire, anti-bullet and anti-explosion, safety in use, energy conservation or direct airborne sound insulation performance |
4 |
Including glass-block wall panels |
|
209 |
31 |
Power, control and communication cables |
All |
Related to fire performance |
1+ |
|
|
210 |
32 |
Joint sealing compounds and profiles |
All |
All |
2+ |
Including kits |
|
211 |
32 |
Sealants for external walls |
Outdoor use |
All |
3 |
Including tapes and kits |
|
212 |
32 |
Sealants for glazing |
All |
All |
3 |
Including kits |
|
213 |
32 |
Sealants for internal walls and partitions |
Indoor use |
All |
4 |
Including kits with profiles and strips |
|
214 |
32 |
Sealants for pedestrian walkways |
All |
All |
3 |
Including kits |
|
215 |
32 |
Sealants for sanitary joints |
All |
All |
3 |
Including kits |
|
216 |
33 |
Anchor channels |
Anchoring use |
All |
1 |
|
|
217 |
33 |
Chemical anchoring kits |
Anchoring use |
All |
1 |
Including epoxy concrete, glass-reinforced polyester and epoxy mortar anchoring kits |
|
218 |
33 |
Metal anchors |
Fixing and/or supporting of elements or heavy units |
All |
1 |
Including fasteners, connectors, cast-in products, bonded products, spiral cable products and kits |
|
219 |
33 |
Metal anchors |
Redundant systems for fixing and/or supporting of elements |
All |
2+ |
Including fasteners |
|
220 |
33 |
Fastening screws |
All |
All |
1 |
|
|
221 |
33 |
Plastic anchors |
Anchoring in concrete and masonry |
All |
2+ |
Including fasteners, kits and products reinforced with glass fibre |
|
222 |
33 |
Insulation fasteners |
All |
Related to structural performance |
2+ |
|
|
223 |
33 |
Insulation fasteners |
All |
Non-related to structural performance |
3 |
|
|
224 |
33 |
Installation support system products for technical building equipment |
All |
Related to fire performance |
1 |
|
|
225 |
33 |
Installation support system products for technical building equipment |
All |
Non-related to fire performance |
4 |
|
|
226 |
33 |
Rock and soil anchor kits |
All |
All |
1+ |
|
|
227 |
34 |
Balustrades |
Prevent falls and not subject to vertical loads |
All |
4 |
|
|
228 |
34 |
Building kits |
All |
Related to fire and safety in use performance |
1 |
Including cold storage rooms |
|
229 |
34 |
Building kits |
All |
Related to structural performance |
2+ |
Including cold storage rooms |
|
230 |
34 |
Building kits |
All |
Related to energy conservation and acoustic performance |
3 |
Including cold storage rooms |
|
231 |
34 |
Building kits |
All |
Non-related to fire, safety, structural, energy conservation or acoustic performance |
4 |
Including cold storage rooms |
|
232 |
34 |
Rockfall protection kits |
All |
All |
1 |
|
|
233 |
34 |
Prefabricated staircases and stair kits |
All |
Related to structural performance |
2+ |
|
|
234 |
34 |
Prefabricated staircases and stair kits |
All |
Related to fire performance |
3 |
|
|
235 |
34 |
Prefabricated staircases and stair kits |
All |
Non-related to fire or structural performance |
4 |
|
|
236 |
34 |
Factory composite panels |
All |
Related to structural performance |
2+ |
Including all combination of layers: concrete, metals, gypsum and timber |
|
237 |
34 |
Factory composite panels |
All |
Non-related to structural performance |
3 |
Including all combination of layers: concrete, metals, gypsum and timber |
|
238 |
34 |
Wall kits |
All |
Related to structural performance |
2+ |
Including internal and external |
|
239 |
34 |
Wall kits |
All |
Related to fire performance |
3 |
Including internal and external |
|
240 |
34 |
Wall kits |
All |
Non-related to fire or structural performance |
4 |
Including internal and external |
|
241 |
34 |
Suspended ceilings |
All |
Related to fire performance |
3 |
|
|
242 |
34 |
Suspended ceilings |
All |
Non-related to fire performance |
4 |
|
|
243 |
34 |
Roofing kits |
All |
Related to fire and structural performance |
3 |
Including green roofs |
|
244 |
34 |
Roofing kits |
All |
Non-related to fire or structural performance |
4 |
|
|
245 |
35 |
Fire protective products |
Fire safety |
All |
1 |
Including coatings |
|
246 |
35 |
Fire stopping and fire sealing products |
Fire safety |
All |
1 |
|
ELI: http://data.europa.eu/eli/reg_del/2026/1310/oj
ISSN 1977-0677 (electronic edition)