EUR-Lex Access to European Union law

Back to EUR-Lex homepage

This document is an excerpt from the EUR-Lex website

Document 01997D0464-20040929

Consolidated text: Commission Decision of 27 June 1997 on the procedure for attesting the conformity of construction products pursuant to Article 20 (2) of Council Directive 89/106/EEC as regards waste water engineering products (Text with EEA relevance) (97/464/EC)

ELI: http://data.europa.eu/eli/dec/1997/464/2004-09-29

1997D0464 — EN — 29.09.2004 — 001.001


This document is meant purely as a documentation tool and the institutions do not assume any liability for its contents

►B

COMMISSION DECISION

of 27 June 1997

on the procedure for attesting the conformity of construction products pursuant to Article 20 (2) of Council Directive 89/106/EEC as regards waste water engineering products

(Text with EEA relevance)

(97/464/EC)

(OJ L 198, 25.7.1997, p.33)

Amended by:

 

 

Official Journal

  No

page

date

►M1

COMMISSION DECISION of 20 September 2004

  L 302

6

29.9.2004




▼B

COMMISSION DECISION

of 27 June 1997

on the procedure for attesting the conformity of construction products pursuant to Article 20 (2) of Council Directive 89/106/EEC as regards waste water engineering products

(Text with EEA relevance)

(97/464/EC)



THE COMMISSION OF THE EUROPEAN COMMUNITIES,

Having regard to the Treaty establishing the European Community,

Having regard to Council Directive 89/106/EEC of 21 December 1988 on the approximation of laws, regulations and administrative provisions of the Member States relating to construction products ( 1 ), as amended by Directive 93/68/EEC ( 2 ), and in particular Article 13 (4) thereof,

Whereas the Commission is required to select, as between the two procedures in accordance with Article 13 (3) of Directive 89/106/EEC for attesting the conformity of a product, the ‘least onerous possible procedure consistent with safety’; whereas this means that it is necessary to decide whether, for a given product or family of products, the existence of a factory production control system under the responsibility of the manufacturer is a necessary and sufficient condition for an attestation of conformity, or whether, for reasons related to compliance with the criteria mentioned in Article 13 (4), the intervention of an approved certification body is required for that purpose;

Whereas Article 13 (4) requires that the procedure thus determined must be indicated in the mandates and in the technical specifications; whereas, therefore, it is desirable to define the concept of products or family of products as used in the mandates and in the technical specifications;

Whereas the two procedures provided for in Article 13 (3) are described in detail in Annex III to Directive 89/106/EEC; whereas it is necessary therefore to specify clearly the methods by which the two procedures must be implemented, by reference to Annex III, for each product or family of products, since Annex III gives preference to certain systems;

Whereas the procedure referred to in point (a) of Article 13 (3) corresponds to the systems set out in the first possibility, without continuous surveillance, and the second and third possibilities of point (ii) of Section 2 of Annex III, and the procedure referred to in point (b) of Article 13 (3) corresponds to the systems set out in point (i) of Section 2 of Annex III, and in the first possibility, with continuous surveillance, of point (ii) of Section 2 of Annex III;

Whereas the measures provided for in this Decision are in accordance with the opinion of the Standing Committee on Construction,

HAS ADOPTED THIS DECISION:



▼M1

Article 1

1.  The products set out in Annex I shall have their conformity attested by procedures set out in Annex II.

2.  When the products referred to in paragraph 1 are additionally subject to regulations on reaction to fire, they shall have their conformity in respect of reaction to fire characteristics attested by procedures set out in Annex III.

▼B

Article 2

The procedure for attesting conformity as set out in Annex II shall be indicated in mandates for harmonized standards.

Article 3

This Decision is addressed to the Member States.




ANNEX I

Waste water engineering products inside buildings

Back-flow devices: air admittance valve ventilating pipework.

Kits for waste water pumping station and effluent lifting plants.

Waste water engineering products outside buildings

Kits and elements for waste water treatment plants and on-site treatment equipment.

Septic tanks.

Prefabricated drainage channel.

Manholes and inspection chambers.

Covers, step irons, ladders and handrail for manholes and inspection chambers, gully tops.

Separators.




ANNEX II

PRODUCT FAMILY

WASTE WATER ENGINEERING PRODUCTS INSIDE BUILDINGS (1/2)

Systems of attestation of conformity

For the product(s) and intended use(s) listed below, CEN/Cenelec is requested to specify the following system(s) of attestation of conformity in the relevant harmonized standard(s):



Product

Intended use

Level or class

Attestation of conformity system

Back-flow devices: air admittance valve ventilating pipework

For use inside buildings

 

(1)

(1)   System 4: See Annex III point 2 (ii) to Directive 89/106/EEC, third possibility.

The specification for the system should be such that it can be implemented even where performance does not need to be determined for a certain characteristic, because at least one Member State has no legal requirement at all for such characteristic (see Article 2.1 of Directive 89/106/EEC and, where applicable, clause 1.2.3 of the Interpretative Documents). In those cases the verification of such a characteristic must not be imposed on the manufacturer if he does not wish to declare the performance of the product in that respect.

PRODUCT FAMILY

WASTE WATER ENGINEERING PRODUCTS INSIDE BUILDINGS (2/2)

Systems of attestation of conformity

For the product(s) and intended use(s) listed below, CEN/Cenelec is requested to specify the following system(s) of attestation of conformity in the relevant harmonized standard(s):



Product(s)

Intended use(s)

Level(s) or class(es)

Attestation of conformity system(s)

Kits for waste water pumping station and effluent lifting plants

For use inside building

 

(1)

(1)   System 3: See Annex III point 2 (ii) to Directive 89/106/EEC, second possibility.

The specification for the system should be such that it can be implemented even where performance does not need to be determined for a certain characteristic, because at least one Member State has no legal requirement at all for such characteristic (see Article 2.1 of Directive 89/106/EEC and, where applicable, clause 1.2.3 of the Interpretative Documents). In those cases the verification of such a characteristic must not be imposed on the manufacturer if he does not wish to declare the performance of the product in that respect.

PRODUCT FAMILY

WASTE WATER ENGINEERING PRODUCTS OUTSIDE BUILDINGS (1/3)

Systems of attestation of conformity

For the product(s) and intended use(s) listed below, CEN/Cenelec is requested to specify the following system(s) of attestation of conformity in the relevant harmonized standard(s):



Product(s)

Intended use(s)

Level(s) or class(es)

Attestation of conformity system(s)

Kits and elements for waste water treatment plants and on-site treatment equipment

—  Septic tanks

To be used outside buildings, for rain water, faecal and organic effluents

 

(1)

(1)   System 3: See Annex III point 2 (ii) to Directive 89/106/EEC, second possibility.

The specification for the system should be such that it can be implemented even where performance does not need to be determined for a certain characteristic, because at least one Member State has no legal requirement at all for such characteristic (see Article 2.1 of Directive 89/106/EEC and, where applicable, clause 1.2.3 of the Interpretative Documents). In those cases the verification of such a characteristic must not be imposed on the manufacturer if he does not wish to declare the performance of the product in that respect.

PRODUCT FAMILY

WASTE WATER ENGINEERING PRODUCTS OUTSIDE BUILDINGS (2/3)

Systems of attestation of conformity

For the product(s) and intended use(s) listed below, CEN/Cenelec is requested to specify the following system(s) of attestation of conformity in the relevant harmonized standard(s):



Product(s)

Intended use(s)

Level(s) or class(es)

Attestation of conformity system(s)

Prefabricated drainage channel

To be used outside buildings, for waste water from buildings and civil engineering works including roads

 

(1)

(1)   System 3: See Annex III point 2 (ii) of Directive 89/106/EEC, second possibility.

The specification for the system should be such that it can be implemented even where performance does not need to be determined for a certain characteristic, because at least one Member State has no legal requirement at all for such characteristic (see Article 2.1 of Directive 89/106/EEC and, where applicable, clause 1.2.3 of the Interpretative Documents). In those cases the verification of such a characteristic must not be imposed on the manufacturer if he does not wish to declare the performance of the product in that respect.

PRODUCT FAMILY

WASTE WATER ENGINEERING PRODUCTS OUTSIDE BUILDINGS (3/3)

Systems of attestation of conformity

For the product(s) and intended use(s) listed below, CEN/Cenelec is requested to specify the following system(s) of attestation of conformity in the relevant harmonized standard(s):

▼M1



Product(s)

Intended use(s)

Level(s) or class(es)

Attestation of conformity system(s)

Manholes and inspection chambers

Step irons, ladders and handrails for manholes and inspection chambers

To be used on carriageways, parking areas, hard shoulders and outside buildings

 

(1)

Separators

for waste water/sewage from buildings and civil engineering works including roads

 

(1)

Manhole tops and gully tops

For use in vehicular and pedestrian areas

 

(2)

(1)   System 4: See Annex III point 2 (ii) to Directive 89/106/EEC, third possibility.

(2)   System 1: See Annex III point 2(i) to Directive 89/106/EEC.

▼B

The specification for the system should be such that it can be implemented even where performance does not need to be determined for a certain characteristic, because at least one Member State has no legal requirement at all for such characteristic (see Article 2.1 of Directive 89/106/EEC and, where applicable, clause 1.2.3 of the Interpretative Documents). In those cases the verification of such a characteristic must not be imposed on the manufacturer if he does not wish to declare the performance of the product in that respect.

▼M1




ANNEX III

PRODUCT FAMILIES

Waste water engineering products inside buildings

Waste water engineering products outside buildings

Systems of attestation of conformity in respect of reaction to fire characteristics

For the product(s) and intended use(s) listed below, CEN/Cenelec is requested to specify the following systems of attestation of conformity in respect of reaction to fire characteristics in the relevant harmonised standard(s):



Product(s)

Intended use(s)

Level(s) or class(es)

(Reaction to fire)

Attestation of conformity system(s)

Back-flow devices: air admittance valve ventilating pipework

For all use(s) when subject to regulations on reaction to fire

A1 (1), A2 (1), B (1), C (1)

1

Kits for waste water pumping station and effluent lifting plants

 

A1 (2), A2 (2), B (2), C (2), D, E

3

Kits and elements for waste water treatment plants and on-site treatment equipment — septic tanks

 

(A1 to E) (3), F

4

Prefabricated drainage channel

 
 
 

Manholes and inspection chambers

 
 
 

Step irons, ladders and handrail for manholes and inspection chambers

 
 
 

Separators

 
 
 

Manhole tops and gully tops

 
 
 

(1)   Products/materials for which a clearly identifiable stage in the production process results in an improvement of the reaction to fire classification (e.g. an addition of fire retardants or a limiting of organic material).

(2)   Products/materials not covered by footnote (1).

(3)   Products/materials that do not require to be tested for reaction to fire (e.g. Products/materials of class A1 according to the Decision 96/603/EC, as amended).

System 1: See Annex III. 2(i), to Directive 89/106/EEC without audit-testing of samples.

System 3: See Annex III. 2(ii) to Directive 89/106/EEC, second possibility.

System 4: See Annex III.2(ii) to Directive 89/106/EEC, third possibility.

The specification for the system should be such that it can be implemented even where performance does not need to be determined for a certain characteristic, because at least one Member State has no legal requirement at all for such characteristic (see Article 2.1 of Directive 89/106/EEC and, where applicable, clause 1.2.3 of the Interpretative Documents). In those cases the verification of such characteristic must not be imposed on the manufacturer if he does not wish to declare the performance of the product in that respect.



( 1 ) OJ No L 40, 11. 2. 1989, p. 12.

( 2 ) OJ No L 220, 30. 8. 1993, p. 1.

Top