Choose the experimental features you want to try

This document is an excerpt from the EUR-Lex website

Document 02006D0771(01)-20220210

    Consolidated text: Commission Decision of 9 November 2006 on harmonisation of the radio spectrum for use by short-range devices (notified under document number C(2006) 5304) (Text with EEA relevance) (2006/771/EC)Text with EEA relevance

    ELI: http://data.europa.eu/eli/dec/2006/771(2)/2022-02-10

    02006D0771(01) — EN — 10.02.2022 — 008.001


    This text is meant purely as a documentation tool and has no legal effect. The Union's institutions do not assume any liability for its contents. The authentic versions of the relevant acts, including their preambles, are those published in the Official Journal of the European Union and available in EUR-Lex. Those official texts are directly accessible through the links embedded in this document

    ►B

    COMMISSION DECISION

    of 9 November 2006

    on harmonisation of the radio spectrum for use by short-range devices

    (notified under document number C(2006) 5304)

    (Text with EEA relevance)

    (2006/771/EC)

    (OJ L 312 11.11.2006, p. 66)

    Amended by:

     

     

    Official Journal

      No

    page

    date

     M1

    COMMISSION DECISION  of 23 May 2008

      L 151

    49

    11.6.2008

     M2

    COMMISSION DECISION  of 13 May 2009

      L 119

    32

    14.5.2009

     M3

    COMMISSION DECISION  of 30 June 2010

      L 166

    33

    1.7.2010

     M4

    COMMISSION IMPLEMENTING DECISION  of 8 December 2011

      L 329

    10

    13.12.2011

    ►M5

    COMMISSION IMPLEMENTING DECISION  of 11 December 2013

      L 334

    17

    13.12.2013

     M6

    COMMISSION IMPLEMENTING DECISION (EU) 2017/1483 of 8 August 2017

      L 214

    3

    18.8.2017

    ►M7

    COMMISSION IMPLEMENTING DECISION (EU) 2019/1345 of 2 August 2019

      L 212

    53

    13.8.2019

    ►M8

    COMMISSION IMPLEMENTING DECISION (EU) 2022/180 of 8 February 2022

      L 29

    17

    10.2.2022


    Corrected by:

     C1

    Corrigendum, OJ L 212, 7.8.2008, p.  15 (2008/432/EC)




    ▼B

    COMMISSION DECISION

    of 9 November 2006

    on harmonisation of the radio spectrum for use by short-range devices

    (notified under document number C(2006) 5304)

    (Text with EEA relevance)

    (2006/771/EC)



    Article 1

    The purpose of this Decision is to harmonise the frequency bands and the related technical parameters for the availability and efficient use of radio spectrum for short-range devices so that such devices may benefit from ‘Class 1’ classification under Commission Decision 2000/299/EC.

    Article 2

    For the purpose of this Decision:

    ▼M7

    1. 

    ‘short-range device’ means a radio device which provides either unidirectional or bidirectional communication and which receives and/or transmits over a short distance at low power;

    2. 

    ‘non-interference and non-protected basis’ means that no harmful interference may be caused to any radiocommunication service and that no claim may be made for protection of these devices against interference originating from radiocommunication services;

    ▼M5

    3. 

    ‘category of short-range devices’ means a group of short-range devices that use spectrum with similar technical spectrum access mechanisms or based on common usage scenarios.

    ▼M5

    Article 3

    1.  
    Member States shall designate and make available, on a non-exclusive, non-interference and non-protected basis, the frequency bands for the categories of short-range devices, subject to the specific conditions and by the implementation deadline, as laid down in the Annex to this Decision.
    2.  
    Notwithstanding paragraph 1, Member States may request the benefit of Article 4(5) of the Radio Spectrum Decision.
    3.  
    This Decision is without prejudice to the right of Member States to allow the use of the frequency bands under less restrictive conditions or for short-range devices which are not part of the harmonised category provided that this does not prevent or reduce the possibility for short-range devices of such a category to rely on the appropriate set of harmonised technical and operational conditions, as specified in the Annex to this Decision, which allow the shared use of a specific part of the spectrum on a non-exclusive basis and for different purposes by short range devices of the same category.

    ▼B

    Article 4

    Member States shall keep the use of the relevant bands under scrutiny and report their findings to the Commission to allow regular and timely review of the Decision.

    ▼M8

    Article 4a

    Member States shall report to the Commission on the implementation of this Decision by 1 October 2022 at the latest.

    ▼B

    Article 5

    This Decision is addressed to the Member States.

    ▼M8




    ANNEX

    Frequency bands with corresponding harmonised technical conditions and implementation deadlines for short-range devices

    Table 1 defines the scope of different categories of short-range devices (defined in Article 2(3)) to which this Decision applies. Table 2 specifies different combinations of frequency band and category of short-range devices, and the harmonised technical conditions for spectrum access and implementation deadlines applicable thereto.

    General technical conditions applicable to all bands and short-range devices that fall within the scope of this Decision:

    — 
    Member States shall allow adjacent frequency bands set out in Table 2 to be used as a single frequency band provided the specific conditions of each of these adjacent frequency bands are met.
    — 
    Member States shall allow the usage of spectrum up to the transmit power, field strength or power density set out in Table 2. Pursuant to Article 3(3), they may impose less restrictive conditions, that is to say allow the use of spectrum with higher transmit power, field strength or power density, provided it does not reduce or compromise the appropriate coexistence between short-range devices in bands harmonised by this Decision.
    — 
    Member States may only impose the additional parameters (channelling and/or channel access and occupation rules) set out in Table 2, and shall not add other parameters or spectrum access and mitigation requirements. Less restrictive conditions pursuant to Article 3(3), means that Member States may completely omit these additional parameters in a given cell or allow higher values, provided that the appropriate sharing environment in the harmonised band is not compromised.
    — 
    Member States may only impose the other usage restrictions set out in Table 2 and shall not add additional usage restrictions. Since less restrictive conditions may be applied pursuant to Article 3(3), Member States may omit one or all of these restrictions, provided that the appropriate sharing environment in the harmonised band is not compromised.
    — 
    Less restrictive conditions pursuant to Article 3(3) shall apply without prejudice to Directive 2014/53/EU.

    For the purposes of this Annex, the following duty cycle definition applies:

    duty cycle ’ means the ratio, expressed as a percentage, of Σ(Ton)/(Tobs) where Ton is the ‘on’ time of a single transmitter device and Tobs is the observation period. Ton is measured in an observation frequency band (Fobs). Unless otherwise specified in this technical annex, Tobs is a continuous one hour period and Fobs is the applicable frequency band in this technical annex. Less restrictive conditions within the meaning of Article 3(3), mean that Member States may allow a higher value for ‘duty cycle’.



    Table 1

    Categories of short-range devices pursuant to Article 2(3) and their scope

    Category of short-range devices

    Scope

    Non-specific short-range devices (SRDs)

    Covers all kinds of radio devices, regardless of the application or their purpose, which fulfil the technical conditions as specified for a given frequency band. Typical uses include telemetry, telecommand, alarms, data transmissions in general and other applications.

    Active medical implant devices

    Covers the radio part of active implantable medical devices that are intended to be fully or partially introduced, surgically or medically, into the human body or that of an animal, and where applicable their peripherals. Active implantable medical devices are defined in Council Directive 90/385/EEC (1).

    Assistive listening devices (ALDs)

    Covers radio communications systems that allow persons with hearing impairment to increase their listening capability. Typical system installations include one or more radio transmitters and one or more radio receivers.

    High duty cycle/continuous transmission devices

    Covers radio devices that rely on low latency and high duty cycle transmissions. These devices are typically used for personal wireless audio and multimedia streaming systems used for combined audio/video transmissions and audio/video sync signals, mobile phones, automotive or home entertainment system, wireless microphones, cordless loudspeakers, cordless headphones, radio devices carried on a person, assistive listening devices, in-ear monitoring, wireless microphones for use at concerts or other stage productions, and low power analogue FM transmitters.

    Inductive devices

    Covers radio devices that use magnetic fields with inductive loop systems for near field communications and determination applications. This typically includes devices for car immobilisation, animal identification, alarm systems, cable detection, waste management, personal identification, wireless voice links, access control, proximity and metal sensors, anti-theft systems as well as RF anti-theft induction systems, data transfer to hand-held devices, automatic article identification, wireless control systems and automatic road tolling.

    Low duty cycle/high reliability devices

    Covers radio devices that rely on low overall spectrum utilisation and low duty cycle spectrum access rules to ensure highly reliable spectrum access and transmissions in shared bands. Typical applications include alarm systems that use radio communication for indicating an alert condition at a distant location and social alarm systems that allow reliable communication for a person in distress.

    Medical data acquisition devices

    Covers the transmission of non-voice data to and from non-implantable medical devices in order to monitor, diagnose and treat patients in healthcare facilities or in their homes as prescribed by duly authorised healthcare professionals.

    PMR446 devices

    Covers hand portable equipment (without base station or repeater use) carried on a person or manually operated, which uses integral antennas only in order to maximise sharing and minimise interference. PMR 446 equipment operates in short-range peer-to-peer mode and shall not be used as a part of infrastructure network nor as a repeater.

    Radio determination devices

    Covers radio devices used for determining the position, velocity and/or other characteristics of an object, or for obtaining information relating to these parameters. Radio determination equipment typically conducts measurements to obtain such characteristics. Radio determination devices exclude any kind of point-to-point or point-to-multipoint radio communications.

    Radio frequency identification (RFID) devices

    Covers tag/interrogator based radio communications systems, consisting of (i) radio devices (tags) attached to animate or inanimate items and (ii) transmitter/receiver units (interrogators) which activate the tags and receive data back. Typical applications include the tracking and identification of items, for instance for the purpose of electronic article surveillance (EAS), and collecting and transmitting data relating to the items to which tags are attached, which may be either battery-less, battery assisted or battery powered. The responses from a tag are validated by its interrogator and passed to its host system.

    Transport and traffic telematics devices

    Covers radio devices that are used in the fields of transport (road, rail, water or air, depending on the relevant technical restrictions), traffic management, navigation, mobility management and in intelligent transport systems (ITS). Typical applications include interfaces between different modes of transport, communication between vehicles (e.g. car to car), between vehicles and fixed locations (e.g. car to infrastructure) as well as communication from and to users.

    Wideband data transmission devices

    Covers radio devices that use wideband modulation techniques to access the spectrum. Typical uses include wireless access systems such as radio local area networks (WAS/RLANs) or wideband SRDs in data networks.

    (1)   

    Council Directive 90/385/EEC of 20 June 1990 on the approximation of the laws of the Member States relating to active implantable medical devices (OJ L 189, 20.7.1990, p. 17).



    Table 2

    Frequency bands with corresponding harmonised technical conditions and implementation deadlines for short-range devices

    Band no

    Frequency band

    Category of short-range devices

    Transmit power limit/field strength limit/power density limit

    Additional parameters (channelling and/or channel access and occupation rules)

    Other usage restrictions

    Implemen-tation deadline

    1

    9-59,750 kHz

    Inductive devices

    72 dΒμΑ/m at 10 metres

     

     

    1 July 2014

    90

    9-148 kHz

    Radio determination devices

    46 dBμA/m at 10 m distance at a reference of 100 Hz, outside the Nuclear Magnetic Resonance (NMR) device.

    Magnetic field strength descending 10 dB/decade above 100Hz.

     

    For enclosed Nuclear Magnetic Resonance (NMR) applications [j].

    1 July 2022

    2

    9-315 kHz

    Active medical implant devices

    30 dΒμΑ/m at 10 metres

    Duty cycle limit: 10 %

    This set of usage conditions is only available to active implantable medical devices.

    1 July 2014

    3

    59,750-60,250 kHz

    Inductive devices

    42 dΒμΑ/m at 10 metres

     

     

    1 July 2014

    4

    60,250-74,750 kHz

    Inductive devices

    72 dBμA/m at 10 metres

     

     

    1 July 2014

    5

    74,750-75,250 kHz

    Inductive devices

    42 dBμA/m at 10 metres

     

     

    1 July 2014

    6

    75,250-77,250 kHz

    Inductive devices

    72 dBμA/m at 10 metres

     

     

    1 July 2014

    7

    77,250-77,750 kHz

    Inductive devices

    42 dBμA/m at 10 metres

     

     

    1 July 2014

    8

    77,750-90 kHz

    Inductive devices

    72 dBμA/m at 10 metres

     

     

    1 July 2014

    9

    90-119 kHz

    Inductive devices

    42 dBμA/m at 10 metres

     

     

    1 July 2014

    10

    119-128,6 kHz

    Inductive devices

    66 dBμA/m at 10 metres

     

     

    1 July 2014

    11

    128,6-129,6 kHz

    Inductive devices

    42 dBμA/m at 10 metres

     

     

    1 July 2014

    12

    129,6-135 kHz

    Inductive devices

    66 dBμA/m at 10 metres

     

     

    1 July 2014

    13

    135-140 kHz

    Inductive devices

    42 dBμA/m at 10 metres

     

     

    1 July 2014

    14

    140-148,5 kHz

    Inductive devices

    37,7 dΒμΑ/m at 10 metres

     

     

    1 July 2014

    15

    148,5-5 000 kHz [1]

    Inductive devices

    -15 dΒμΑ/m at 10 metres in any bandwidth of 10 kHz.

    Furthermore the total field strength is -5 dΒμΑ/m at 10 m for systems operating at bandwidths larger than 10 kHz

     

     

    1 July 2014

    91

    148-5 000 kHz

    Radio determination devices

    -15 dBμA/m at 10 m distance outside the Nuclear Magnetic Resonance (NMR) device.

     

    For enclosed Nuclear Magnetic Resonance (NMR) applications [j].

    1 July 2022

    17

    400-600 kHz

    Radio Frequency Identification (RFID) devices

    -8 dΒμΑ/m at 10 metres

     

     

    1 July 2014

    85

    442,2-450,0 kHz

    Non-specific short-range devices

    7 dBμA/m at 10 m

    Channel spacing ≥ 150 Hz

    This set of usage conditions is only available for person detection and collision avoidance devices.

    1 January 2020

    18

    456,9-457,1 kHz

    Non-specific short-range devices

    7 dBμA/m at 10 m

     

    This set of usage conditions is only available for emergency detections of buried victims and valuable items devices.

    1 July 2014

    19

    984-7 484 kHz

    Transport and Traffic Telematics devices

    9 dΒμΑ/m at 10 m

    Duty cycle limit: 1 %

    This set of usage conditions is only available for Eurobalise transmissions in the presence of trains using the 27 090 -27 100 kHz band for telepowering pursuant to the conditions set for band 28.

    1 July 2014

    20

    3 155 -3 400 kHz

    Inductive devices

    13,5 dΒμΑ/m at 10 metres

     

     

    1 July 2014

    21

    5 000 -30 000 kHz [2]

    Inductive devices

    -20 dΒμΑ/m at 10 metres in any bandwidth of 10 kHz. Furthermore the total field strength is -5 dΒμΑ/m at 10 m for systems operating at bandwidths larger than 10 kHz

     

     

    1 July 2014

    92

    5 000 -30 000 kHz

    Radio determination devices

    -5 dBμA/m at 10m distance outside the Nuclear Magnetic Resonance (NMR) device.

     

    For enclosed Nuclear Magnetic Resonance (NMR) applications [j].

    1 July 2022

    22

    6 765 -6 795 kHz

    Inductive devices

    42 dΒμΑ/m at 10 metres

     

     

    1 July 2014

    23

    7 300 -23 000 kHz

    Transport and Traffic Telematics devices

    -7 dΒμΑ/m at 10 m

    Antenna requirements apply [8].

    This set of usage conditions is only available for Eurobalise transmissions in the presence of trains using the 27 090 -27 100 kHz band for telepowering pursuant to the conditions set for band 28.

    1 July 2014

    24

    7 400 -8 800 kHz

    Inductive devices

    9 dΒμΑ/m at 10 metres

     

     

    1 July 2014

    25

    10 200 -11 000 kHz

    Inductive devices

    9 dΒμΑ/m at 10 metres

     

     

    1 July 2014

    27a

    13 553 -13 567 kHz

    Inductive devices

    42 dΒμΑ/m at 10 metres

    Transmission mask and antenna requirements for all combined frequency segments apply [8], [9].

     

    1 January 2020

    27b

    13 553 -13 567 kHz

    Radio Frequency Identification (RFID) devices

    60 dΒμΑ/m at 10 metres

    Transmission mask and antenna requirements for all combined frequency segments apply [8], [9].

     

    1 July 2014

    27c

    13 553 -13 567 kHz

    Non-specific short-range devices

    10 mW e.r.p.

     

     

    1 July 2014

    28

    26 957 -27 283 kHz

    Non-specific short-range devices

    10 mW e.r.p.

     

     

    1 July 2014

    29

    26 990 -27 000 kHz

    Non-specific short-range devices

    100 mW e.r.p.

    Duty cycle limit: 0,1 %.

    Model control devices [d] may operate without duty cycle restrictions.

     

    1 July 2014

    30

    27 040 -27 050 kHz

    Non-specific short-range devices

    100 mW e.r.p.

    Duty cycle limit: 0,1 %.

    Model control devices [d] may operate without duty cycle restrictions.

     

    1 July 2014

    31

    27 090 -27 100 kHz

    Non-specific short-range devices

    100 mW e.r.p.

    Duty cycle limit: 0,1 %.

    Model control devices [d] may operate without duty cycle restrictions.

     

    1 July 2014

    32

    27 140 -27 150 kHz

    Non-specific short-range devices

    100 mW e.r.p.

    Duty cycle limit: 0,1 %.

    Model control devices [d] may operate without duty cycle restrictions.

     

    1 July 2014

    33

    27 190 -27 200 kHz

    Non-specific short-range devices

    100 mW e.r.p.

    Duty cycle limit: 0,1 %.

    Model control devices [d] may operate without duty cycle restrictions.

     

    1 July 2014

    34

    30-37,5 MHz

    Active medical implant devices

    1 mW e.r.p.

    Duty cycle limit: 10 %

    This set of usage conditions is only available to ultra-low power medical membrane implants for blood pressure measurements within the definition of active implantable medical devices.

    1 July 2014

    93

    30-130 MHz

    Radio determination devices

    -36 dBm e.r.p. outside the Nuclear Magnetic Resonance (NMR) device.

     

    For enclosed Nuclear Magnetic Resonance (NMR) applications [j].

    1 July 2022

    35

    40,66-40,7 MHz

    Non-specific short-range devices

    10 mW e.r.p.

     

     

    1 January 2018

    36

    87,5-108 MHz

    High duty cycle/continuous transmission devices

    50 nW e.r.p.

    Channel spacing up to 200 kHz.

    This set of usage conditions is only available to wireless audio and multimedia streaming transmitters with analogue frequency modulation (FM).

    1 July 2014

    37a

    169,4-169,475 MHz

    Assistive Listening Devices (ALD)

    500 mW e.r.p.

    Channel spacing: max 50 kHz.

     

    1 July 2014

    37c

    169,4-169,475 MHz

    Non-specific short-range devices

    500 mW e.r.p.

    Channel spacing: max 50 kHz.

    Duty cycle limit: 1,0 %.

    For metering devices [a], the duty cycle limit is 10,0 %

     

    1 July 2014

    38

    169,4-169,4875 MHz

    Non-specific short-range devices

    10 mW e.r.p.

    Duty cycle limit: 0,1 %.

     

    1 January 2020

    39a

    169,4875-169,5875 MHz

    Assistive Listening Devices (ALD)

    500 mW e.r.p.

    Channel spacing: max 50 kHz.

     

    1 July 2014

    39b

    169,4875-169,5875 MHz

    Non-specific short-range devices

    10 mW e.r.p.

    Duty cycle limit: 0,001 %.

    Between 00:00h and 06:00h local time a duty cycle limit of 0,1 % may be used.

     

    1 January 2020

    40

    169,5875-169,8125 MHz

    Non-specific short-range devices

    10 mW e.r.p.

    Duty cycle limit: 0,1 %.

     

    1 January 2020

    82

    173,965-216 MHz

    Assistive Listening Devices (ALD)

    10 mW e.r.p.

    On a tuning range basis [5]. Channel spacing: max 50 kHz. A threshold of 35 dBμV/m is required to ensure the protection of a DAB receiver located at 1,5 m from the ALD device, subject to DAB signal strength measurements taken around the ALD operating site. The ALD device should operate under all circumstances at least 300 kHz away from the channel edge of an occupied DAB channel.

    Requirements on techniques to access spectrum and mitigate interference apply [7].

     

    1 January 2018

    41

    401-402 MHz

    Active medical implant devices

    25 μW e.r.p.

    Channel spacing: 25 kHz.

    Individual transmitters may combine adjacent channels for increased bandwidth up to 100 kHz.

    Requirements on techniques to access spectrum and mitigate interference apply [7].

    Alternatively, a duty cycle limit of 0,1 % may also be used.

    This set of usage conditions is only available for systems specifically designed for the purpose of providing non-voice digital communications between active implantable medical devices and/or body-worn devices and other devices external to the human body used for transferring non-time critical individual patient-related physiological information.

    1 July 2014

    42

    402-405 MHz

    Active medical implant devices

    25 μW e.r.p.

    Channel spacing: 25 kHz.

    Individual transmitters may combine adjacent channels for increased bandwidth up to 300 kHz.

    Other techniques to access spectrum or mitigate interference, including bandwidths greater than 300 kHz, can be used provided they ensure compatible operation with the other users and in particular with meteorological radiosondes [7].

    This set of usage conditions is only available to active implantable medical devices.

    1 July 2014

    43

    405-406 MHz

    Active medical implant devices

    25 μW e.r.p.

    Channel spacing: 25 kHz

    Individual transmitters may combine adjacent channels for increased bandwidth up to 100 kHz.

    Requirements on techniques to access spectrum and mitigate interference apply [7].

    Alternatively a duty cycle limit of 0,1 % may also be used.

    This set of usage conditions is only available for systems specifically designed for the purpose of providing non-voice digital communications between active implantable medical devices and/or body-worn devices and other devices external to the human body used for transferring non-time critical individual patient-related physiological information.

    1 July 2014

    86

    430-440 MHz

    Medical data acquisition devices

    -50 dBm/100kHz e.r.p. power density but not exceeding a total power of -40 dBm/10MHz (both limits are intended for measurement outside of the patient’s body)

     

    The set of usage conditions is only available for Ultra-Low Power Wireless Medical Capsule Endoscopy (ULP-WMCE) applications [h].

    1 January 2020

    44a

    433,05-434,79 MHz

    Non-specific short-range devices

    1 mW e.r.p. and -13 dBm/10 kHz power density for bandwidth modulation larger than 250 kHz

     

    Voice applications are allowed with advanced mitigation techniques. Other audio and video applications are excluded.

    1 July 2014

    44b

    433,05-434,79 MHz

    Non-specific short-range devices

    10 mW e.r.p.

    Duty cycle limit: 10 %

     

    1 January 2020

    45c

    434,04-434,79 MHz

    Non-specific short-range devices

    10 mW e.r.p.

    Duty cycle limit: 100 % subject to channel spacing up to 25 kHz.

    Voice applications are allowed with advanced mitigation techniques. Other audio and video applications are excluded.

    1 January 2020

    83

    446,0-446,2 MHz

    PMR446

    500 mW e.r.p.

    Requirements on techniques to access spectrum and mitigate interference apply [7].

     

    1 January 2018

    87

    862-863 MHz

    Non-specific short-range devices

    25 mW e.r.p.

    Duty cycle limit: 0,1 %.

    Bandwidth: ≤ 350 kHz.

     

    1 January 2020

    46a

    863-865 MHz

    Non-specific short-range devices

    25 mW e.r.p.

    Requirements on techniques to access spectrum and mitigate interference apply [7].

    Alternatively, a duty cycle limit of 0,1 % may also be used.

     

    1 January 2018

    46b

    863-865 MHz

    High duty cycle/continuous transmission devices

    10 mW e.r.p.

     

    This set of usage conditions is only available to wireless audio and multimedia streaming devices.

    1 July 2014

    84

    863-868 MHz

    Wideband data transmission devices

    25 mW e.r.p.

    Requirements on techniques to access spectrum and mitigate interference apply [7].

    Bandwidth: > 600 kHz and ≤ 1 MHz.

    Duty cycle: ≤ 10 % for network access points [g]

    Duty cycle: ≤ 2,8 % otherwise

    This set of usage conditions is only available for wideband SRDs in data networks [g].

    1 January 2018

    47

    865-868 MHz

    Non-specific short-range devices

    25 mW e.r.p.

    Requirements on techniques to access spectrum and mitigate interference apply [7].

    Alternatively, a duty cycle limit of 1 % may also be used.

     

    1 January 2020

    47a

    865-868 MHz [6]

    Radio Frequency Identification (RFID) devices

    2 W e.r.p.

    Interrogator transmissions at 2 W e.r.p. only permitted within the four channels centred at 865,7 MHz, 866,3 MHz, 866,9 MHz and 867,5 MHz

    RFID interrogator devices placed on the market before the repeal date of EC Decision 2006/804/EC are ‘grandfathered’, i.e. they are continuously permitted to be used in line with the provisions set out in EC Decision 2006/804/EC before the repeal date.

    Requirements on techniques to access spectrum and mitigate interference apply [7].

    Bandwidth ≤ 200 kHz

     

    1 January 2018

    47b

    865-868 MHz

    Non-specific short-range devices

    500 mW e.r.p.

    Transmissions only permitted within the frequency ranges 865,6-865,8 MHz, 866,2-866,4 MHz, 866,8-867,0 MHz and 867,4-867,6 MHz.

    Adaptive Power Control (APC) required. Alternatively other mitigation technique with at least an equivalent level of spectrum compatibility.

    Requirements on techniques to access spectrum and mitigate interference apply [7].

    Bandwidth: ≤ 200 kHz

    Duty cycle: ≤ 10 % for network access points [g]

    Duty cycle: ≤ 2,5 % otherwise

    This set of usage conditions is only available for data networks [g].

    1 January 2018

    48

    868-868,6 MHz

    Non-specific short-range devices

    25 mW e.r.p.

    Requirements on techniques to access spectrum and mitigate interference apply [7].

    Alternatively, a duty cycle limit of 1 % may also be used.

     

    1 January 2020

    49

    868,6-868,7 MHz

    Low duty cycle/high reliability devices

    10 mW e.r.p.

    Channel spacing: 25 kHz. The whole frequency band may also be used as a single channel for high-speed data transmission.

    Duty cycle limit: 1,0 %

    This set of usage conditions is only available to alarm systems [e].

    1 July 2014

    50

    868,7-869,2 MHz

    Non-specific short-range devices

    25 mW e.r.p.

    Requirements on techniques to access spectrum and mitigate interference apply [7].

    Alternatively a duty cycle limit of 0,1 % may also be used.

     

    1 January 2020

    51

    869,2-869,25 MHz

    Low duty cycle/high reliability devices

    10 mW e.r.p.

    Channel spacing: 25 kHz. Duty cycle limit: 0,1 %

    This set of usage conditions is only available to social alarm devices [b].

    1 July 2014

    52

    869,25-869,3 MHz

    Low duty cycle/high reliability devices

    10 mW e.r.p.

    Channel spacing: 25 kHz. Duty cycle limit: 0,1 %

    This set of usage conditions is only available to alarm systems [e].

    1 July 2014

    53

    869,3-869,4 MHz

    Low duty cycle/high reliability devices

    10 mW e.r.p.

    Channel spacing: 25 kHz. Duty cycle limit: 1,0 %

    This set of usage conditions is only available to alarm systems [e].

    1 July 2014

    54

    869,4-869,65 MHz

    Non-specific short-range devices

    500 mW e.r.p.

    Requirements on techniques to access spectrum and mitigate interference apply [7].

    Alternatively, a Duty cycle limit of 10 % may also be used.

     

    1 January 2020

    55

    869,65-869,7 MHz

    Low duty cycle/high reliability devices

    25 mW e.r.p.

    Channel spacing: 25 kHz Duty cycle limit: 10 %

    This set of usage conditions is only available to alarm systems [e].

    1 July 2014

    56a

    869,7-870 MHz

    Non-specific short-range devices

    5 mW e.r.p.

     

    Voice applications are allowed with advanced mitigation techniques. Other audio and video applications are excluded.

    1 July 2014

    56b

    869,7-870 MHz

    Non-specific short-range devices

    25 mW e.r.p.

    Requirements on techniques to access spectrum and mitigate interference apply [7].

    Alternatively, a duty cycle limit of 1 % may also be used.

     

    1 January 2020

    57a

    2 400 -2 483,5 MHz

    Non-specific short-range devices

    10 mW equivalent isotropic radiated power (e.i.r.p.)

     

     

    1 July 2014

    57b

    2 400 -2 483,5 MHz

    Radio determination devices

    25 mW e.i.r.p.

     

     

    1 July 2014

    57c

    2 400 -2 483,5 MHz

    Wideband data transmission devices

    100 mW e.i.r.p. and 100 mW/100 kHz e.i.r.p. density applies when frequency hopping modulation is used, 10 mW/MHz e.i.r.p. density applies when other types of modulation are used

    Requirements on techniques to access spectrum and mitigate interference apply [7].

     

    1 July 2014

    58

    2 446 -2 454 MHz

    Radio Frequency Identification (RFID) devices

    500 mW e.i.r.p.

    Requirements on techniques to access spectrum and mitigate interference apply [7].

     

    1 July 2014

    59

    2 483,5 -2 500 MHz

    Active medical implant devices

    10 mW e.i.r.p.

    Requirements on techniques to access spectrum and mitigate interference apply [7].

    Channel spacing: 1 MHz. The whole frequency band may also be used dynamically as a single channel for high-speed data transmissions.

    In addition, a duty cycle limit of 10 % applies.

    This set of usage conditions is only available to active implantable medical devices.

    Peripheral master units are for indoor use only.

    1 July 2014

    59a

    2 483,5 -2 500 MHz

    Medical data acquisition devices

    1 mW e.i.r.p.

    Requirements on techniques to access spectrum and mitigate interference apply [7].

    Modulation Bandwidth: ≤ 3 MHz.

    In addition, a duty cycle: ≤ 10 % applies.

    The set of usage conditions is only available for medical body area network system (MBANS) [f] for indoor use within healthcare facilities

    1 January 2018

    59b

    2 483,5 -2 500 MHz

    Medical data acquisition devices

    10 mW e.i.r.p.

    Requirements on techniques to access spectrum and mitigate interference apply [7].

    Modulation Bandwidth: ≤ 3 MHz.

    In addition, a duty cycle: ≤ 2 % applies

    The set of usage conditions is only available for medical body area network system (MBANS) [f] for indoor use within the patient’s home

    1 January 2018

    60

    4 500 -7 000 MHz

    Radio determination devices

    24 dBm e.i.r.p. [3]

    Requirements on techniques to access spectrum and mitigate interference apply [7].

    This set of usage conditions is only available to Tank Level Probing Radar [c].

    1 July 2014

    61

    5 725 -5 875 MHz

    Non-specific short-range devices

    25 mW e.i.r.p.

     

     

    1 July 2014

    62

    5 795 -5 815 MHz

    Transport and Traffic Telematics devices

    2 W e.i.r.p.

    Requirements on techniques to access spectrum and mitigate interference apply [7].

    This set of usage conditions applies only to road tolling applications and smart tachograph, weight and dimension applications [i].

    1 January 2020

    88

    5 855 -5 865 MHz

    Transport and Traffic Telematics devices

    33 dBm e.i.r.p., 23 dBm/MHz e.i.r.p. density and a Transmit Power Control (TPC) range of 30 dB

    Requirements on techniques to access spectrum and mitigate interference apply [7].

    This set of usage conditions is only available to vehicle-to-vehicle, vehicle-to-infrastructure and infrastructure-to-vehicle systems.

    1 January 2020

    89

    5 865 -5 875 MHz

    Transport and Traffic Telematics devices

    33 dBm e.i.r.p., 23 dBm/MHz e.i.r.p. density and a Transmit Power Control (TPC) range of 30 dB

    Requirements on techniques to access spectrum and mitigate interference apply [7].

    This set of usage conditions is only available to vehicle-to-vehicle, vehicle-to-infrastructure and infrastructure-to-vehicle systems.

    1 January 2020

    63

    6 000 -8 500 MHz

    Radio determination devices

    7 dBm/50 MHz peak e.i.r.p. and -33 dBm/MHz mean e.i.r.p.

    Automatic power control and antenna requirements as well as requirements on techniques to access spectrum and mitigate interference apply [7], [8] [10].

    This set of usage conditions is only available to Level Probing Radar.

    Established exclusion zones around radio astronomy sites shall be obeyed.

    1 July 2014

    64

    8 500 -10 600 MHz

    Radio determination devices

    30 dBm e.i.r.p. [3]

    Requirements on techniques to access spectrum and mitigate interference apply [7].

    This set of usage conditions is only available to Tank Level Probing Radar [c].

    1 July 2014

    65

    17,1-17,3 GHz

    Radio determination devices

    26 dBm e.i.r.p.

    Requirements on techniques to access spectrum and mitigate interference apply [7].

    This set of usage conditions is only available to ground-based systems.

    1 July 2014

    66

    24,05-24,075 GHz

    Transport and Traffic Telematics devices

    100 mW e.i.r.p.

     

     

    1 July 2014

    67

    24,05-26,5 GHz

    Radio determination devices

    26 dBm/50 MHz peak e.i.r.p. and -14 dBm/MHz mean e.i.r.p.

    Automatic power control and antenna requirements as well as requirements on techniques to access spectrum and mitigate interference apply [7]. [8], [10]

    This set of usage conditions is only available to Level Probing Radar.

    Established exclusion zones around radio astronomy sites shall be obeyed.

    1 July 2014

    68

    24,05-27 GHz

    Radio determination devices

    43 dBm e.i.r.p. [3]

    Requirements on techniques to access spectrum and mitigate interference apply [7].

    This set of usage conditions is only available to Tank Level Probing Radar [c].

    1 July 2014

    69a

    24,075-24,15 GHz

    Transport and Traffic Telematics devices

    100 mW e.i.r.p.

    Requirements on techniques to access spectrum and mitigate interference apply [7].

    This set of usage conditions is only available to ground-based vehicle radars.

    1 July 2014

    69b

    24,075-24,15 GHz

    Transport and Traffic Telematics devices

    0,1 mW e.i.r.p.

     

     

    1 July 2014

    70a

    24,15-24,25 GHz

    Non-specific short-range devices

    100 mW e.i.r.p.

     

     

    1 July 2014

    70b

    24,15-24,25 GHz

    Transport and Traffic Telematics devices

    100 mW e.i.r.p.

     

     

    1 July 2014

    74a

    57-64 GHz

    Non-specific short-range devices

    100 mW e.i.r.p. and a maximum transmit power of 10 dBm

     

     

    1 January 2020

    74b

    57-64 GHz

    Radio determination devices

    43 dBm e.i.r.p. [3]

    Requirements on techniques to access spectrum and mitigate interference apply [7].

    This set of usage conditions is only available to Tank Level Probing Radar [c].

    1 July 2014

    74c

    57-64 GHz

    Radio determination devices

    35 dBm/50 MHz peak e.i.r.p. and -2 dBm/MHz mean e.i.r.p.

    Automatic power control and antenna requirements as well as requirements on techniques to access spectrum and mitigate interference apply [7] [8], [10].

    This set of usage conditions is only available to Level Probing Radar.

    1 July 2014

    75

    57-71 GHz

    Wideband data transmission devices

    40 dBm e.i.r.p. and 23 dBm/MHz e.i.r.p. density

    Requirements on techniques to access spectrum and mitigate interference apply [7].

    Fixed outdoor installations are excluded.

    1 January 2020

    75a

    57-71 GHz

    Wideband data transmission devices

    40 dBm e.i.r.p., 23 dBm/MHz e.i.r.p. density and maximum transmit power of 27 dBm at the antenna port or ports

    Requirements on techniques to access spectrum and mitigate interference apply [7].

     

    1 January 2020

    75b

    57-71 GHz

    Wideband data transmission devices

    55 dBm e.i.r.p., 38 dBm/MHz e.i.r.p. density and a transmit antenna gain ≥ 30 dBi

    Requirements on techniques to access spectrum and mitigate interference apply [7].

    This set of usage conditions is only available to fixed outdoor installations.

    1 January 2020

    76

    61-61,5 GHz

    Non-specific short-range devices

    100 mW e.i.r.p.

     

     

    1 July 2014

    77

    63,72-65,88 GHz

    Transport and Traffic Telematics devices

    40 dBm e.i.r.p.

    TTT devices placed on the market before the 1 January 2020 are ‘grandfathered’, i.e. they are permitted to use the previous frequency range 63-64 GHz, and otherwise the same conditions apply.

    This set of usage conditions is only available to vehicle-to-vehicle, vehicle-to-infrastructure and infrastructure-to-vehicle systems.

    1 January 2020

    78a

    75-85 GHz

    Radio determination devices

    34dBm/50 MHz peak e.i.r.p. and -3 dBm/MHz mean e.i.r.p.

    Automatic power control and antenna requirements as well as requirements on techniques to access spectrum and mitigate interference apply [7], [8], [10].

    This set of usage conditions is only available to Level Probing Radar.

    Established exclusion zones around radio astronomy sites shall be obeyed.

    1 July 2014

    78b

    75-85 GHz

    Radio determination devices

    43 dBm e.i.r.p. [3]

    Requirements on techniques to access spectrum and mitigate interference apply [7].

    This set of usage conditions is only available to Tank Level Probing Radar [c].

    1 July 2014

    79a

    76-77 GHz

    Transport and Traffic Telematics devices

    55 dBm peak e.i.r.p. and 50 dBm mean e.i.r.p. and 23,5 dBm mean e.i.r.p. for pulse radars

    Requirements on techniques to access spectrum and mitigate interference apply [7].

    Fixed transportation infrastructure radars have to be of a scanning nature in order to limit the illumination time and ensure a minimum silent time to achieve coexistence with automotive radar systems.

    This set of usage conditions is only available to ground-based vehicle and infrastructure systems.

    1 June 2020

    79b

    76-77 GHz

    Transport and Traffic Telematics devices

    30 dBm peak e.i.r.p. and

    3 dBm/MHz average power spectral density

    Duty cycle limit: ≤ 56 %/s

    This set of usage conditions is only available to obstacle detection systems for rotorcraft use [4].

    1 January 2018

    80a

    122-122,25 GHz

    Non-specific short-range devices

    10 dBm/250MHz e.i.r.p. and

    -48 dBm/MHz at 30° elevation

     

     

    1 January 2018

    80b

    122,25-123 GHz

    Non-specific short-range devices

    100 mW e.i.r.p.

     

     

    1 January 2018

    81

    244-246 GHz

    Non-specific short-range devices

    100 mW e.i.r.p.

     

     

    1 July 2014

    Applications and devices referred to in Table 2:

    [a] ‘Metering devices’ means radio devices that are part of bidirectional radio communications systems which allow remote monitoring, measuring and transmission of data in smart grid infrastructures, such as electricity, gas and water.

    [b] ‘Social alarm devices’ means radio communications systems that allow reliable communication for a person in distress in a confined area to initiate a call for assistance. Typical uses of social alarm are to assist elderly or disabled people.

    [c] ‘Tank Level Probing Radar’ (TLPR) means a specific type of radiodetermination application, which is used for tank level measurements and is installed in metallic or reinforced concrete tanks, or similar structures made of material with comparable attenuation characteristics. The purpose of the tank is to contain a substance.

    [d] ‘Model control devices’ means a specific kind of telecommand and telemetry radio equipment that is used to remotely control the movement of models (principally miniature representations of vehicles) in the air, on land or over or under the water surface.

    [e] An alarm system is a device which uses radio communication support for indicating an alert to a system or a person, as a main functionality, at a distant location when a problem or a specific situation occurs. Radio alarms include social alarms and alarms for security and safety.

    [f] Medical Body Area Network Systems (MBANSs) are used for medical data acquisition and are intended for low-power wireless networking of a plurality of body-worn sensors and/or actuators as well as of a hub device placed on/around the human body.

    [g] A network access point in a data network is a fixed terrestrial short-range device that acts as a connection point for the other short-range devices in the data network to service platforms located outside of that data network. The term data network refers to several short-range devices, including the network access point, as network components and to the wireless connections between them.

    [h] Wireless medical capsule endoscopy is used for medical data acquisition designed for use in medical doctor-patient scenarios with the aim of acquiring images of human digestive tract.

    [i] Smart tachograph, weight and dimension applications are defined as remote enforcement of the tachograph in Appendix 14 of Commission Implementing Regulation 2016/799 ( 1 ) and for the weights and dimensions enforcement in Article 10d of Directive 2015/719 ( 2 ).

    [j] Enclosed NMR sensors are devices where the material/object under investigation is put inside the enclosure of the NMR device. NMR techniques use nuclear magnetic resonance excitation and magnetic field strength response of a material/object under test to get information about material properties based on resonance frequency responses of isotopes of atoms. Nuclear magnetic resonance imaging and magnetic resonance tomography systems are not included in this scope.

    Other technical requirements and clarifications referred to in Table 2:

    [1] In band 20 higher field strengths and additional usage restrictions apply for inductive applications.

    [2] In bands 22, 24, 25, 27a, and 28 higher field strengths and additional usage restrictions apply for inductive applications.

    [3] The power limit applies inside a closed tank and corresponds to a spectral density of -41,3 dBm/MHz e.i.r.p. outside a 500 litre test tank.

    [4] Member States can specify exclusion zones or equivalent measures in which the obstacle detection application for rotorcraft use shall not be used for the protection of the radioastronomy service or other national use. Rotorcraft is defined as EASA CS-27 and CS-29 (resp. JAR-27 and JAR-29 for former certifications).

    [5] Devices shall implement the whole frequency range on a tuning range basis.

    [6] RFID tags respond at a very low power level (-20 dBm e.r.p.) in a frequency range around the RFID interrogator channels and shall comply with the essential requirements of Directive 2014/53/EU.

    [7] Techniques to access spectrum and mitigate interference that provide an appropriate level of performance to comply with the essential requirements of Directive 2014/53/EU shall be used. If relevant techniques are described in harmonised standards or parts thereof the references of which have been published in the Official Journal of the European Union under Directive 2014/53/EU, performance at least equivalent to these techniques shall be ensured.

    [8] Antenna requirements that provide an appropriate level of performance to comply with the essential requirements of Directive 2014/53/EU shall be used. If relevant restrictions are described in harmonised standards or parts thereof the references of which have been published in the Official Journal of the European Union under Directive 2014/53/EU, performance at least equivalent to these restrictions shall be ensured.

    [9] Transmission mask that provides an appropriate level of performance to comply with the essential requirements of Directive 2014/53/EU shall be used. If relevant restrictions are described in harmonised standards or parts thereof the references of which have been published in the Official Journal of the European Union under Directive 2014/53/EU, performance at least equivalent to these restrictions shall be ensured.

    [10] Automatic power control that provides an appropriate level of performance to comply with the essential requirements of Directive 2014/53/EU shall be used. If relevant restrictions are described in harmonised standards or parts thereof the references of which have been published in the Official Journal of the European Union under Directive 2014/53/EU, performance at least equivalent to these restrictions shall be ensured.



    ( 1 ) Commission Implementing Regulation (EU) 2016/799 of 18 March 2016 implementing Regulation (EU) No 165/2014 of the European Parliament and of the Council laying down the requirements for the construction, testing, installation, operation and repair of tachographs and their components (OJ L 139, 26.5.2016, p. 1).

    ( 2 ) Directive (EU) 2015/719 of the European Parliament and of the Council of 29 April 2015 amending Council Directive 96/53/EC laying down for certain road vehicles circulating within the Community the maximum authorised dimensions in national and international traffic and the maximum authorised weights in international traffic (OJ L 115, 6.5.2015, p. 1).

    Top