EUR-Lex Access to European Union law
This document is an excerpt from the EUR-Lex website
Document 52014XC0314(03)
Commission communication in the framework of the implementation of Directive 2004/22/EC of the European Parliament and of the Council on measuring instruments (Publication of the references to normative documents drawn up by OIML and the list of the parts thereof corresponding to the essential requirements (in conformity with Article 16.1 of the Directive)) Text with EEA relevance
Commission communication in the framework of the implementation of Directive 2004/22/EC of the European Parliament and of the Council on measuring instruments (Publication of the references to normative documents drawn up by OIML and the list of the parts thereof corresponding to the essential requirements (in conformity with Article 16.1 of the Directive)) Text with EEA relevance
Commission communication in the framework of the implementation of Directive 2004/22/EC of the European Parliament and of the Council on measuring instruments (Publication of the references to normative documents drawn up by OIML and the list of the parts thereof corresponding to the essential requirements (in conformity with Article 16.1 of the Directive)) Text with EEA relevance
OJ C 76, 14.3.2014, p. 1–20
(BG, ES, CS, DA, DE, ET, EL, EN, FR, HR, IT, LV, LT, HU, MT, NL, PL, PT, RO, SK, SL, FI, SV)
14.3.2014 |
EN |
Official Journal of the European Union |
C 76/1 |
Commission communication in the framework of the implementation of Directive 2004/22/EC of the European Parliament and of the Council on measuring instruments (1)
(Publication of the references to normative documents drawn up by OIML and the list of the parts thereof corresponding to the essential requirements (in conformity with Article 16.1 of the Directive))
(Text with EEA relevance)
2014/C 76/01
MI-002: Gas meters
in relation to:
— |
OIML R 137 Edition 2012 |
Notes:
The column ‘Comment’ indicates the compliance between OIML R 137 and the relevant requirement in Directive 2004/22/EC.
The indication ‘Covered’ means that:
— |
The requirement of OIML R 137 is identical to the one of Directive 2004/22/EC; or |
— |
The requirement of OIML R 137 is more severe than the one of Directive 2004/22/EC; or |
— |
All of the requirement of OIML R 137 fulfils requirements in Directive 2004/22/EC (even when Directive 2004/22/EC allows other alternatives); |
— |
In case the requirement is not fully covered, a short statement explains what is covered. |
The indication ‘Not Covered’ means that the requirement in Directive 2004/22/EC is either not compatible with the relevant OIML R 137 requirement or not included in OIML R 137.
The indication ‘Not Relevant’ means that the requirement in Annex I of Directive 2004/22/EC is not relevant for gas meters.
Essential requirements in MID (Annex 1 and MI-002) |
OIML R 137 (2012) |
Comment |
ANNEX 1 |
||
1.1 |
5.3.1 |
Covered, except for Qmin to Qt |
1.2 |
5.13.7 5.13.3 5.13.7 |
Covered |
1.3 |
5.1 |
Covered |
1.3.1 |
5.1 |
Covered |
1.3.2 |
5.12 A.5.1 A.5.2 |
Covered except M3 (M3 is not relevant) |
1.3.3 |
5.13.7 |
Covered except for E2 and E3 (E2 and E3 are not relevant) |
1.3.4 |
5.13.7 |
Only covered for voltage variations unless the design of the instrument is such that other quantities do not influence in a significant way the accuracy of the instrument |
1.4 |
|
|
1.4.1 |
chapter 5 A.1 |
Covered |
1.4.2 |
A.4.2.1 A.4.2.2 |
Covered |
2 |
5.6 |
Covered, except for Qmin ≤ Q ≤ Qt |
3 |
5.7 |
Covered |
4 |
6.3.3 |
Covered |
5 |
5.10 |
Covered |
6 |
6.1.1 6.7 |
Covered |
7 |
|
|
7.1 |
6.1.4 9.1.1 |
Covered |
7.2 |
6 |
Covered |
7.3 |
5.11 6.7.2 |
Covered, except for flow rates below Qmin |
7.4 |
|
Not relevant |
7.5 |
6.1.1 6.1.4 |
Covered |
7.6 |
6.4.1 12.2 I.1.1 Annex I |
Covered |
8 |
|
|
8.1 |
5.13.8 6.5.1 9.1.4.2 |
Covered |
8.2 |
9.1.1 9.1.3 |
Covered |
8.3 |
I.1.1 I.1.3 |
Covered |
8.4 |
I.1.3 |
Covered |
8.5 |
6.3.1 |
Covered |
9 |
|
|
9.1 |
7 |
Covered |
9.2 |
7.1 |
Covered |
9.3 |
8.1 |
Covered |
9.4 |
8.1 |
Covered |
9.5 |
6.4.2 6.3.1 |
Covered |
9.6 |
|
Not relevant |
9.7 |
4.1 |
Covered |
9.8 |
7.1 |
Covered |
10 |
|
|
10.1 |
6.3.1 |
Covered |
10.2 |
6.3.1 |
Covered |
10.3 |
3.1.8 |
Covered |
10.4 |
|
Not relevant |
10.5 |
6.1.5 |
Covered, except for a remote display |
11 |
|
|
11.1 |
|
Not relevant |
11.2 |
|
Not relevant |
12 |
10 11.1.1 12.3 |
Covered |
ANNEX MI-002 |
||
Definitions |
3.1.1 3.3.3 3.3.2 3.3.4 3.4.3 & 5.11 |
Covered |
1 |
12.2 |
Covered |
1.1 |
5.2 |
Covered for class 1.5 if Qmax/Qmin ≥ 150 Covered for class 1.0 if Qmax/Qmin ≥ 20 |
1.2 |
5.1 12.6.7.1 |
Covered |
1.3 |
5.1 |
Covered |
1.4 |
5.1 |
Covered |
1.5 |
5.1 |
Covered |
2 |
|
|
2.1 |
5.3 5.4 |
Covered |
2.2 |
5.3.5 |
Covered, except if the selected temperature tsp does not lie between 15 °C and 25 °C |
3 |
|
|
3.1 |
|
|
3.1.1 |
5.13.7 |
Covered except for radiated and conducted RF EM Field |
3.1.2 |
12.6.15 |
Covered |
3.1.3 |
Table 5 3.2.7 |
Covered for the first clause of the requirement |
3.2 |
5.13.3 |
Covered |
4 |
|
|
4.1 |
|
|
4.1.1 |
5.10 |
Covered |
4.1.2 |
5.10 |
Covered |
4.2 |
|
|
4.2.1 |
5.10 |
Not covered |
4.2.2 |
5.10 |
Not covered |
5 |
|
|
5.1 |
6.6.2 |
Not Covered |
5.2 |
6.6.4 |
Covered by one of the alternatives when the battery has a 5 years lifetime |
5.3 |
6.3.2 |
Not covered |
5.4 |
12.6.4 |
Covered |
5.5 |
6.4.1 |
Covered |
5.6 |
5.13.2 |
Covered |
6 |
4.1 |
Covered if kg or m3 is used |
MI-006: Automatic Gravimetric Filling Instruments
in relation to:
— |
OIML R 61-1 Edition 2004 (E) and D 11 Edition 2004 (E) |
Notes:
The column ‘Comment’ indicates the compliance between OIML R 61-1 and D 11 and the relevant requirement in Directive 2004/22/EC.
The indication ‘Covered’ means that:
— |
The requirement of OIML R 61-1 and D 11 is identical to the one of Directive 2004/22/EC; or |
— |
The requirement of OIML R 61-1 and D 11 is more severe than the one of Directive 2004/22/EC; or |
— |
All of the requirement of OIML R 61-1 and D 11 fulfils requirements in Directive 2004/22/EC (even when Directive 2004/22/EC allows other alternatives); |
— |
In case the requirement is not fully covered, a short statement explains what is covered. |
The indication ‘Not Covered’ means that the requirement in Directive 2004/22/EC is either not compatible with the relevant OIML R 61-1 and D 11 requirement or not included in OIML R 61-1 and D 11.
The indication ‘Not Relevant’ means that the requirement in Annex I of Directive 2004/22/EC is not relevant for automatic gravimetric filling instruments.
Essential requirements in MID (Annex I and MI-006 common part and chapter V) |
OIML R 61-1 Edition 2004 (E) and D11 2004 (E) |
Comment |
||||
Annex I |
|
|
||||
1.1 |
2.2, 2.3, 2.4, 2.5, 4.1.1 |
Covered |
||||
1.2 |
4.1.2 |
Covered (except for permanent continuous electromagnetic fields) |
||||
1.3 |
5.2.1 |
Covered |
||||
1.3.1 |
2.8.1, 4.2.1, 5.2.1, 2.8.1 |
Covered except for condensing humidity or intended location |
||||
1.3.2 |
|
Not relevant |
||||
1.3.3 |
|
|
||||
|
|
|
||||
|
D11 (14.2.2) |
Covered on the provision that test pulse 5, according to ISO 7637-2:2004 is used. |
||||
b) |
A.6.4, 4.1.2, 4.2.3 A.6.3.1, D11 (13.4) A.6.3.2, D11 (13.5), D11 (12.4) A.6.3.3 A.6.3.4.1, D11 (12.1.1), A.6.3.4.2, D11 (12.1.2), D11 (13.8), D11 (12.5), |
Covered on provision that the relevant severity level of OIML D11:2004 is used. |
||||
1.3.4 |
2.8.2, A.6.2.4, 2.8.3, 4.2.6, A.6.4 D11 (13.3) D11 (12.3) 4.2.4, A.5.2, T.3.13, 2.8.4, A.6.2.5, 2.8.1.3, A.6.2.2 |
Covered |
||||
1.4 |
|
|
||||
1.4.1 |
A.6, A.6.1.1, Annex A |
Covered |
||||
1.4.2 |
4.2.1, A.6.2.3 |
Covered except for the damp heat condensing test |
||||
2 |
4.3.3, A.7 |
Covered |
||||
3 |
|
Covered by all other tests |
||||
4 |
|
Covered by all other tests |
||||
5 |
4.1.3, 4.3.3, A.7 |
Covered |
||||
6 |
3.2.2, 3.2.3, 3.4, 3.5, 3.6, 3.7, 3.8, 3.9, 4.1.2, 4.2 |
Covered |
||||
7 |
|
|
||||
7.1 |
3.2.1, 3.2.2 |
Covered |
||||
7.2 |
3.1 |
Covered |
||||
7.3 |
|
Not relevant |
||||
7.4 |
|
Not relevant |
||||
7.5 |
3.1 |
Covered |
||||
7.6 |
3.7, A.8, T.1.9, 3.12, 6.4, 6.5.2, T 2.1.4, 3.2.3, 3.2.4 |
Covered except for test procedures |
||||
8 |
|
|
||||
8.1 |
3.2.3, 3.2.4, 3.3.3, 4.2.5 |
Covered |
||||
8.2 |
3.2.3, 3.2.4 |
Covered |
||||
8.3 |
3.2.4 |
Covered |
||||
8.4 |
3.2.2, 3.2.3, 3.2.4 |
Covered |
||||
8.5 |
|
Not relevant |
||||
9 |
|
|
||||
9.1 |
3.10 |
Covered |
||||
9.2 |
|
Not relevant |
||||
9.3 |
|
Not covered |
||||
9.4 |
|
Not relevant |
||||
9.5 |
3.3.2 |
Covered |
||||
9.6 |
|
Not relevant |
||||
9.7 |
2.9 |
Covered |
||||
9.8 |
3.10.4, 3.11 |
Covered |
||||
10 |
|
|
||||
10.1 |
T.2.3, 3.3 |
Covered |
||||
10.2 |
3.3.1 to 3.3.4 |
Covered |
||||
10.3 |
3.3.3 |
Not covered |
||||
10.4 |
|
Not relevant |
||||
10.5 |
|
Not relevant |
||||
11 |
|
|
||||
11.1 |
|
Not relevant |
||||
11.2 |
|
Not relevant |
||||
12 |
3.7 |
Covered |
||||
Annex MI-006 |
|
|
||||
Definitions |
T.1.6, T.1.7, T.1.8 |
Covered |
||||
Chapter I – Requirements common to all types of automatic weighing instruments |
||||||
1 |
5.1.1, 4.1.1, 5.2.1 |
Covered |
||||
1.1 |
2.6, T.3.7, T.3.8 |
Covered |
||||
1.2 |
2.8.2, 2.8.3 |
Covered |
||||
1.3 |
2.8.1 |
Covered |
||||
1.4 |
3.10.1, 3.10.3 |
Covered |
||||
2 |
|
|
||||
3 |
|
|
||||
3.1 |
T.2.1.3, T.2.1.4, 2.8.4, 3.4, 3.5, 3.6, 3.7 |
Covered |
||||
3.2 |
3.4, 3.5, 3.6, 3.7 |
Covered |
||||
3.3 |
3.3.1, 3.4, 3.5, 3.6 |
Covered |
||||
3.4 |
4.2.2 |
Covered |
||||
3.5 |
T.2.4, 3.8, T.2.5, 3.8.5, 3.8.6 |
Covered |
||||
3.6 |
3.3.3, 3.8.5.2 |
Covered |
||||
4 |
|
|
||||
Chapter III – Automatic Gravimetric Filling Instruments |
||||||
1 |
|
|
||||
1.1 |
5.2.1, 2.1, 2.2.2 |
Covered |
||||
1.2 |
2.1, 2.2.1, 2.2.2, 5.3.4 |
Covered |
||||
1.3 |
2.2.1 |
Covered |
||||
1.4 |
2.2.2 |
Covered |
||||
2 |
|
|
||||
2.1 |
|
|
||||
2.1.1 |
2.5 |
Covered |
||||
2.1.2 |
2.5, A.6.1.3.2, T.3.10 |
Covered |
||||
2.2 |
2.2.2, Table1, 5.3.2, 2.3, T.3.2 |
Covered |
||||
2.3 |
2.4, T.3.3 |
Covered |
||||
3 |
|
|
||||
3.1 |
2.5, T.3.4 |
Covered |
||||
3.2 |
4.1.2, 4.2.3, T.3.1, A.6.1.3.1 |
Covered |
||||
3.3 |
5.2.1, T.3.9, 2.7, T.3.12 |
Covered |
MI-006: Automatic Rail Weighbridges
in relation to:
— |
OIML R 106-1 Edition 1997 (E) and D 11 Edition 2004 (E) |
Notes:
The column ‘Comment’ indicates the compliance between OIML R 106-1 and D 11 and the relevant requirement in Directive 2004/22/EC.
The indication ‘Covered’ means that:
— |
The requirement of OIML R 106-1 and D 11 is identical to the one of Directive 2004/22/EC; or |
— |
The requirement of OIML R 106-1 and D 11 is more severe than the one of Directive 2004/22/EC; or |
— |
All of the requirement of OIML R 106-1 and D 11 fulfils requirements in Directive 2004/22/EC (even when Directive 2004/22/EC allows other alternatives); |
— |
In case the requirement is not fully covered, a short statement explains what is covered. |
The indication ‘Not Covered’ means that the requirement in Directive 2004/22/EC is either not compatible with the relevant OIML R 106-1 and D 11 requirement or not included in OIML R 106-1 and D 11.
The indication ‘Not Relevant’ means that the requirement in Annex I of Directive 2004/22/EC is not relevant for automatic rail weighbridges.
Essential requirements in MID (Annex I and MI-006 common part and chapter VI) |
OIML R 106-1 Edition 1997 (E) and D11 2004 (E) |
Comment |
||||
Annex I |
|
|
||||
1.1 |
2.2.1, 4.1.1 |
Covered |
||||
1.2 |
4.1.2, 4.3.4 |
Covered (except that R106-1 does not cover permanent continuous electromagnetic field) |
||||
1.3 |
5.1.1 |
Covered |
||||
1.3.1 |
2.9.1, 4.3.3, 5.1.1, (A.8.1, A.8.2), 2.9.1 |
Covered except R106-1 makes no reference to condensing humidity or intended location |
||||
1.3.2 |
|
Not Relevant |
||||
1.3.3 |
|
|
||||
|
|
|
||||
|
D11 (14.2.2), |
Covered on the provision that test pulse 5, according to ISO 7637-2:2004 is used. |
||||
b) |
(4.1.2, 4.3.4) A.9.1, D11 (13.4), A.9.2, D11 (12.4), D11 (13.5) A.9.3 A.9.4, D11 (12.1.1) D11 (12.1.2) D11 (13.8), D11 (12.5) |
Covered on the provision that the relevant severity level specified in OIML D11 (2004) is used |
||||
1.3.4 |
2.9.2, 4.3.7, A.8.3/2.9.3, 4.3.8, A.8.4,D11 (13.3) D11 (12.3) 4.3.5, A.7.1 |
Covered |
||||
1.4 |
|
|
||||
1.4.1 |
5.1.3.2, A.8, Annex A |
Covered |
||||
1.4.2 |
4.3.3, A.8.2 |
Covered except for the damp heat condensing test |
||||
2 |
4.4.3, A.10 |
Covered |
||||
3 |
|
Covered by all other tests |
||||
4 |
2.8.1.6, A.6.5.3 |
Covered |
||||
5 |
4.1.3, 4.4.3, A.10 |
Covered |
||||
6 |
3.3, 3.4.2, 3.4.3, 3.4.4, 3.4.5, 4.1.2, 4.3.1, 4.3.4 |
Covered |
||||
7 |
|
|
||||
7.1 |
2.7, 2.10, 3.2, 3.3.1 |
Covered except for non-facilitation of fraudulent use |
||||
7.2 |
3.2 |
Covered |
||||
7.3 |
|
Not relevant |
||||
7.4 |
|
Not relevant |
||||
7.5 |
3.2, 3.5.2 |
Covered |
||||
7.6 |
3.5.1, 2.8.3.2, 2.8.1, A.11.3 |
Covered except for test procedures and associated software |
||||
8 |
|
|
||||
8.1 |
4.3.6 |
Covered |
||||
8.2 |
3.3.1, 3.3.2 |
Covered |
||||
8.3 |
|
Not covered |
||||
8.4 |
|
Not covered |
||||
8.5 |
|
Not relevant |
||||
9 |
|
|
||||
9.1 |
3.6 |
Covered |
||||
9.2 |
|
Not relevant |
||||
9.3 |
A1 |
Not covered |
||||
9.4 |
|
Not relevant |
||||
9.5 |
2.3, 3.4.1 |
Covered |
||||
9.6 |
|
Not relevant |
||||
9.7 |
3.6.1, 3.6.2.1 |
Covered |
||||
9.8 |
3.6.5, 3.7 |
Covered |
||||
10 |
|
|
||||
10.1 |
3.1, 3.4.1, 3.4.2 |
Covered |
||||
10.2 |
2.6, 3.4.1, 3.4.2 |
Covered |
||||
10.3 |
|
Not covered |
||||
10.4 |
|
Not relevant |
||||
10.5 |
|
Not relevant |
||||
11 |
|
|
||||
11.1 |
3.1, 3.4.2 |
Covered |
||||
11.2 |
3.1 |
Not covered |
||||
12 |
5 |
Covered |
||||
Annex MI-006 |
|
|
||||
Definitions |
T.1.1, T.1.2, T.1.3 |
Covered |
||||
Chapter I – Requirements common to all types of automatic weighing instruments |
||||||
1 |
5.1.1 |
Covered |
||||
1.1 |
2.4, Table 3 |
Covered |
||||
1.2 |
2.9.2, 4.3.7, 2.9.3, 4.3.8 |
Covered |
||||
1.3 |
2.9.1 |
Covered |
||||
1.4 |
3.4.4, 3.6.4 |
Covered |
||||
2 |
|
|
||||
3 |
|
|
||||
3.1 |
3.1, 3.4.4, 3.4.5 |
Covered |
||||
3.2 |
3.1, 3.5 |
Covered |
||||
3.3 |
3.4.1 |
Covered |
||||
3.4 |
4.3.2 |
Covered |
||||
3.5 |
3.3.5, A.6.2, 2.8.1.2, A.6.5.1 |
Covered |
||||
3.6 |
3.4.3 |
Covered |
||||
4 |
|
|
||||
Chapter VI – Automatic Rail Weighbridges |
||||||
1 |
2.1 |
Covered |
||||
2 |
|
|
||||
2.1 |
2.2.1, 2.8.2 |
Covered |
||||
2.2 |
2.8.2.1 |
Covered |
||||
2.3 |
2.8.2.2 |
Covered |
||||
2.4 |
2.2.1 |
Covered |
||||
3 |
2.3 |
Covered |
||||
4 |
|
|
||||
4.1 |
2.4 |
Covered |
||||
4.2 |
2.5 |
Covered |
||||
5 |
|
|
||||
5.1 |
2.2.2 (Table 2) |
Covered |
||||
5.2 |
T.4.2.5, 4.1.2, 4.3.4, A.9 |
Covered |
MI-006: Continuous Totalisers
in relation to:
— |
OIML R 50-1 Edition 1997 (E) and D 11 Edition 2004 (E) |
Notes:
The column ‘Comment’ indicates the compliance between OIML R 50-1 and D 11 and the relevant requirement in Directive 2004/22/EC.
The indication ‘Covered’ means that:
— |
The requirement of OIML R 50-1 and D 11 is identical to the one of Directive 2004/22/EC; or |
— |
The requirement of OIML R 50-1 and D 11 is more severe than the one of Directive 2004/22/EC; or |
— |
All of the requirement of OIML R 50-1 and D 11 fulfils requirements in Directive 2004/22/EC (even when Directive 2004/22/EC allows other alternatives); |
— |
In case the requirement is not fully covered, a short statement explains what is covered. |
The indication ‘Not Covered’ means that the requirement in Directive 2004/22/EC is either not compatible with the relevant OIML R 50-1 and D 11 requirement or not included in OIML R 50-1 and D 11.
The indication ‘Not Relevant’ means that the requirement in Annex I of Directive 2004/22/EC is not relevant for continuous totalisers.
Essential requirements in MID (Annex I and MI-006 common part and chapter V) |
OIML R 50-1 Edition 1997 (E) and D11 2004 (E) |
Comment |
||||
Annex I |
|
|
||||
1.1 |
4.1.1, 2.2.1, 2.2.3 |
Covered |
||||
1.2 |
4.1.2, 4.3, 4.5.2 |
Covered except for permanent continuous electromagnetic fields |
||||
1.3 |
5.1.1 |
Covered |
||||
1.3.1 |
2.5.4.1, 4.5.1 |
Covered except for condensing humidity or intended location |
||||
1.3.2 |
|
Not Relevant |
||||
1.3.3 |
|
|
||||
|
|
|
||||
|
D11 (14.2.2) |
Covered on the provision that test pulse 5, according to ISO 7637-2:2004, is used |
||||
b) |
4.1.2 & 4.5.2 A.8.1, D11 (13.4) A.8.2, D11 (13.5), D11 (12.4) A.8.3 A.8.4, D11 (12.1.1), D11 (12.1.2) D11 (13.8), D11 (12.5) |
Covered on the provision that the relevant severity level specified in OIML D11 (2004) is used |
||||
1.3.4 |
2.5.4.3, 4.5.5, A.7.4, 2.5.4.4, 4.5.6, A.7.5 D11 (13.3) D11 (12.3) A.9.4, 4.5.3, A.6.1.1, A.6.1.2 (T.4.9) 2.5.2, A.6.3.2 2.5.1, A.6.3.1 2.5.4.2, A.7.2 |
Covered |
||||
1.4 |
|
|
||||
1.4.1 |
5.1.3.4, Annex A |
Covered |
||||
1.4.2 |
4.5.1, A.7.3 |
Covered except for the damp heat condensing test |
||||
2 |
|
Covered by all other tests |
||||
3 |
2.5.5.1, A.9.1, 2.6.1 |
Covered |
||||
4 |
2.5.5.2, A.9.2, 2.5.5.3, A.9.3, 2.6.3, A.10.2 |
Covered |
||||
5 |
4.1.3 |
Covered |
||||
6 |
3.2.1 to 3.2.6, 3.3.1, 3.4, 3.6 to 3.8, 4.1.2, 4.3 |
Covered |
||||
7 |
|
|
||||
7.1 |
2.2.2, 3.1, 3.2, 3.3.6, 3.10 |
Covered |
||||
7.2 |
3.1 |
Covered |
||||
7.3 |
|
Not relevant |
||||
7.4 |
|
Not relevant |
||||
7.5 |
3.1, 3.7, 3.8 |
Covered |
||||
7.6 |
5.2.1.1, A.10, A.11 |
Covered except for test procedures Software not covered |
||||
8 |
|
|
||||
8.1 |
3.2.6, 3.9, 4.5.4 |
Covered |
||||
8.2 |
3.10 |
Covered |
||||
8.3 |
|
Not covered |
||||
8.4 |
|
Not covered |
||||
8.5 |
|
Not relevant |
||||
9 |
|
|
||||
9.1 |
3.11 |
Covered |
||||
9.2 |
|
Not relevant |
||||
9.3 |
|
Not covered |
||||
9.4 |
|
Not relevant |
||||
9.5 |
3.3.2, 3.3.1 |
Covered |
||||
9.6 |
|
Not relevant |
||||
9.7 |
3.11 |
Covered |
||||
9.8 |
3.11.5, 3.12 |
Covered |
||||
10 |
|
|
||||
10.1 |
3.3 |
Covered |
||||
10.2 |
3.3 |
Covered |
||||
10.3 |
3.3.1 |
Covered for printing only |
||||
10.4 |
|
Not relevant |
||||
10.5 |
|
Not relevant |
||||
11 |
|
|
||||
11.1 |
3.3 |
Not covered |
||||
11.2 |
|
Not covered |
||||
12 |
5 |
Covered |
||||
Annex MI-006 |
|
|
||||
Definitions |
T1.1, T.1.2, T1.3 |
Covered |
||||
Chapter I – Requirements common to all types of automatic weighing instruments |
||||||
1 |
4.1.1, 5.1.1 |
Covered |
||||
1.1 |
T.4.4, 5.1.1 |
Covered |
||||
1.2 |
2.5.4.3, 2.5.4.4, 5.1.1 |
Covered |
||||
1.3 |
2.5.4.1, 5.1.1 |
Covered |
||||
1.4 |
2.4, 5.1.1 |
Covered |
||||
2 |
|
|
||||
3 |
|
|
||||
3.1 |
3.1, 3.6, 3.7, 3.8, 4.1.1 |
Covered |
||||
3.2 |
3.8 |
Covered |
||||
3.3 |
3.2.4, 3.3.1 |
Covered |
||||
3.4 |
4.4 |
Covered |
||||
3.5 |
2.5.3, 2.5.5.4, 2.5.5.5, 3.5, A.6.3.3, A.6.3.4, 2.6.2, A.10.1, 2.6.3, A.10.2, 2.6.4, A.10.3 |
Covered |
||||
3.6 |
3.4 |
Not covered |
||||
4 |
|
|
||||
Chapter V – Continuous Totalisers |
||||||
1 |
2.1 |
Covered |
||||
2 |
|
|
||||
2.1 |
2.3, 2.4, 5.1.1 |
Covered |
||||
2.2 |
2.3 |
Covered |
||||
3 |
2.2.1 - Table 1 |
Covered |
||||
4 |
5.1.1, 3.8.3, 3.8 (4th bullet) |
Covered |
||||
5 |
3.2.2 |
Covered |
||||
6 |
|
|
||||
6.1 |
2.2.3 |
Covered |
||||
6.2 |
T.5.5 |
Covered |
MI-006: Discontinuous Totalisers
in relation to:
— |
OIML R 107-1 Edition 2007 (E) |
Notes:
The column ‘Comment’ indicates the compliance between OIML R 107-1 and the relevant requirement in Directive 2004/22/EC.
The indication ‘Covered’ means that:
— |
The requirement of OIML R 107-1 is identical to the one of Directive 2004/22/EC; or |
— |
The requirement of OIML R 107-1 is more severe than the one of Directive 2004/22/EC; or |
— |
All of the requirement of OIML R 107-1 fulfils requirements in Directive 2004/22/EC (even when Directive 2004/22/EC allows other alternatives); |
— |
In case the requirement is not fully covered, a short statement explains what is covered. |
The indication ‘Not Covered’ means that the requirement in Directive 2004/22/EC is either not compatible with the relevant OIML R 107-1 requirement or not included in OIML R 107-1.
The indication ‘Not Relevant’ means that the requirement in Annex I of Directive 2004/22/EC is not relevant for discontinuous totalisers.
Essential requirements in MID (Annex I and MI-006 common part and chapter IV) |
OIML R 107-1 Edition 2007 |
Comment |
||||
Annex I |
|
|
||||
1.1 |
2.2, 4.1.1 |
Covered |
||||
1.2 |
4.1.2, 4.2.1, 4.2.4 |
Covered except for permanent continuous electromagnetic field |
||||
1.3 |
5.1.1 |
Covered |
||||
1.3.1 |
2.7.1.1, 4.2.3 |
Covered except for condensing humidity or intended location |
||||
1.3.2 |
|
Not Relevant |
||||
1.3.3 |
|
|
||||
|
|
|
||||
|
A.7.4.6 |
Covered on the provision that test pulse 5, test level IV according to ISO 7637-2:2004(E), is used |
||||
b) |
A.7.4.1, A.7.4.2, A.7.4.4, A.7.4.5.1, A.7.4.5.2, A.7.4.3 |
Covered for E1 Covered for E2 on the provision that the relevant severity level specified in OIML D11 (2004) is used |
||||
1.3.4 |
2.7.2, 4.2.8, A.7.3.4, A.7.3.5, 4.2.5, A.5.3 |
Covered on the provision that the relevant severity level specified in OIML D11 (2004) is used |
||||
1.4 |
|
|
||||
1.4.1 |
A.7.1, Annex A |
Covered |
||||
1.4.2 |
A.7.3.3, 4.2.3 |
Covered except for the damp heat condensing test |
||||
2 |
6.7.3, A.8 |
Covered |
||||
3 |
T.3.9 |
Covered |
||||
4 |
|
Covered by all other tests |
||||
5 |
4.1.3, 6.7.3, A.8 |
Covered |
||||
6 |
3.2.2 - 3.2.5, 3.4.1, 4.1.2, 4.2.1, 4.2.4 |
Covered |
||||
7 |
|
|
||||
7.1 |
2.6, 3.2.1, 3.2.2, 3.2.3, 3.2.9 |
Covered |
||||
7.2 |
3.1, 3.2.4, 3.2.5, 3.2.7, 3.2.11 |
Covered |
||||
7.3 |
|
Not relevant |
||||
7.4 |
|
Not relevant |
||||
7.5 |
3.1 |
Covered |
||||
7.6 |
3.7, 5.1.2.2, 5.2.2, 3.6.2 |
Covered except for test procedures |
||||
8 |
|
|
||||
8.1 |
4.2.6 |
Covered |
||||
8.2 |
3.3 |
Covered |
||||
8.3 |
3.6 |
Covered |
||||
8.4 |
3.5, 3.6 |
Covered |
||||
8.5 |
|
Not relevant |
||||
9 |
|
|
||||
9.1 |
3.9 |
Covered except for the indication of the presence of additional devices |
||||
9.2 |
|
Not relevant |
||||
9.3 |
3.7, 3.8, 5.1.1 |
Covered |
||||
9.4 |
|
Not relevant |
||||
9.5 |
2.3, 3.4.2.1 |
Covered |
||||
9.6 |
|
Not relevant |
||||
9.7 |
2.8, 3.9 |
Covered |
||||
9.8 |
3.9.4, 3.10 |
Covered |
||||
10 |
|
|
||||
10.1 |
2.6, 3.4 |
Covered |
||||
10.2 |
2.6, 3.4.1, 3.4.2, 3.4.3, 3.4.4 |
Covered |
||||
10.3 |
|
Not covered |
||||
10.4 |
|
Not relevant |
||||
10.5 |
|
Not relevant |
||||
11 |
|
|
||||
11.1 |
3.4, 3.5 |
Covered |
||||
11.2 |
3.4, 3.5 |
Covered |
||||
12 |
5 |
Covered |
||||
Annex MI-006 |
|
|
||||
Definitions |
T.1.2, T.1.4 |
Covered |
||||
Chapter I – Requirements common to all types of automatic weighing instruments |
||||||
1 |
|
|
||||
1.1 |
5.1.1 |
Covered |
||||
1.2 |
5.1.1 |
Covered |
||||
1.3 |
2.7.1.1 |
Covered |
||||
1.4 |
5.1.1 |
Covered |
||||
2 |
|
|
||||
3 |
|
|
||||
3.1 |
3.1, 3.2 |
Covered |
||||
3.2 |
3.2.3, 3.2.9 |
Covered |
||||
3.3 |
3.4.1 |
Covered |
||||
3.4 |
4.2.2 |
Covered |
||||
3.5 |
3.8 |
Covered |
||||
3.6 |
3.2.5 |
Covered |
||||
4 |
|
|
||||
Chapter IV – Discontinuous Totalisers |
||||||
1 |
2.1 |
Covered |
||||
2 |
2.2.1 Table 1 |
Covered |
||||
3 |
2.4 |
Covered |
||||
4 |
2.5 |
Covered |
||||
5 |
3.8, 3.8.3 |
Covered |
||||
6 |
3.2.7 |
Covered |
||||
7 |
3.4.3 |
Covered |
||||
8 |
|
|
||||
8.1 |
2.2.2 Table 2 |
Covered |
||||
8.2 |
T.4.5.6, 4.1.2, 4.2.4.a |
Covered |