EUR-Lex Access to European Union law

Back to EUR-Lex homepage

This document is an excerpt from the EUR-Lex website

Document 32011D0232

2011/232/EU: Commission Decision of 11 April 2011 amending Decision 2000/367/EC establishing a classification system for resistance-to-fire performance for construction products, construction works and parts thereof (notified under document C(2011) 2417) Text with EEA relevance

OJ L 97, 12.4.2011, p. 49–50 (BG, ES, CS, DA, DE, ET, EL, EN, FR, IT, LV, LT, HU, MT, NL, PL, PT, RO, SK, SL, FI, SV)
Special edition in Croatian: Chapter 13 Volume 054 P. 243 - 244

Legal status of the document In force

ELI: http://data.europa.eu/eli/dec/2011/232(1)/oj

12.4.2011   

EN

Official Journal of the European Union

L 97/49


COMMISSION DECISION

of 11 April 2011

amending Decision 2000/367/EC establishing a classification system for resistance-to-fire performance for construction products, construction works and parts thereof

(notified under document C(2011) 2417)

(Text with EEA relevance)

(2011/232/EU)

THE EUROPEAN COMMISSION,

Having regard to the Treaty on the Functioning of the European Union,

Having regard to Council Directive 89/106/EEC of 21 December 1988 on the approximation of laws, regulations and administrative provisions of the Member States relating to construction products (1), and in particular Article 20(2) thereof,

After consulting the Standing Committee on Construction,

Whereas:

(1)

Commission Decision 2000/367/EC of 3 May 2000 implementing Council Directive 89/106/EEC as regards the classification of the resistance to fire performance of construction products, construction works and parts thereof (2) should be amended to take into account technical progress in the development of the relevant test methods and in order to include cavity barriers.

(2)

Decision 2000/367/EC should therefore be amended accordingly,

HAS ADOPTED THIS DECISION:

Article 1

The Annex to Decision 2000/367/EC is amended in accordance with the Annex to this Decision.

Article 2

This Decision is addressed to the Member States.

Done at Brussels, 11 April 2011.

For the Commission

Antonio TAJANI

Vice-President


(1)   OJ L 40, 11.2.1989, p. 12.

(2)   OJ L 133, 6.6.2000, p. 26.


ANNEX

The Annex to Decision 2000/367/EC is amended as follows:

(1)

in Section 3 ‘Products and systems for protecting load-bearing elements or parts of works’, the classification table that relates to ‘ceilings with no independent fire resistance’ is replaced by the following table:

‘Applies to

ceilings with no independent fire resistance

Standard(s)

EN 13501-2; prEN 13381-1

Classification: expressed in the same terms as the load-bearing element being protected

Notes

If also fulfilling the requirement with regard to the “semi-natural” fire, the symbol “sn” is added to the classification.’

(2)

in Section 3 ‘Products and systems for protecting load-bearing elements or parts of works’, the classification table that relates to ‘fire protective coatings, boards, renderings, claddings and screens’ is replaced by the following table:

‘Applies to

fire protective coatings, boards, renderings, claddings and screens

Standard(s)

EN 13501-2; prEN 13381-2 to 8

Classification: expressed in the same terms as the load-bearing element being protected

Notes

—’

(3)

in Section 4 ‘Non-load bearing elements or parts of works and products therefor’, the classification table that relates to ‘partitions (including those incorporating uninsulated portions)’ is replaced by the following table:

‘Applies to

partitions (including partitions incorporating uninsulated portions, and cavity barriers)

Standard(s)

EN13501-2; EN 1364-1 (*1); EN 1992-1-2; EN 1993-1-2; EN 1994-1-2; EN 1995-1-2; EN 1996-1-2; EN 1999-1-2

Classification: -

 

E

 

20

30

 

60

90

120

 

 

 

EI

15

20

30

45

60

90

120

180

240

 

EI-M

 

 

30

 

60

90

120

180

240

 

EW

 

20

30

 

60

90

120

 

 

 

Notes


(*1)  For cavity barriers this standard is complemented by EOTA TR 031.’