This document is an excerpt from the EUR-Lex website
Document 32016L0844R(01)
Corrigendum to Commission Directive (EU) 2016/844 of 27 May 2016 amending Directive 2009/45/EC of the European Parliament and of the Council on safety rules and standards for passenger ships (OJ L 141, 28.5.2016)
Corrigendum to Commission Directive (EU) 2016/844 of 27 May 2016 amending Directive 2009/45/EC of the European Parliament and of the Council on safety rules and standards for passenger ships (OJ L 141, 28.5.2016)
Corrigendum to Commission Directive (EU) 2016/844 of 27 May 2016 amending Directive 2009/45/EC of the European Parliament and of the Council on safety rules and standards for passenger ships (OJ L 141, 28.5.2016)
C/2016/4440
IO L 193, 19.7.2016, p. 117–120
(BG, ES, CS, DA, DE, ET, EL, EN, FR, HR, IT, LV, LT, HU, MT, NL, PL, PT, RO, SK, SL, FI, SV)
ELI: http://data.europa.eu/eli/dir/2016/844/corrigendum/2016-07-19/oj
19.7.2016 |
EN |
Official Journal of the European Union |
L 193/117 |
Corrigendum to Commission Directive (EU) 2016/844 of 27 May 2016 amending Directive 2009/45/EC of the European Parliament and of the Council on safety rules and standards for passenger ships
( Official Journal of the European Union L 141 of 28 May 2016 )
On page 55, in Table 5.1(a) in paragraph (2), subparagraph (h) of the Annex, concerning the Annex to Directive 2009/45/EC:
for:
‘Table 5.1(a)
Fire integrity of bulkheads separating adjacent spaces
Spaces |
|
(1) |
(2) |
(3) |
(4) |
(5) |
(6) |
(7) |
(8) |
(9) |
(10) |
(11) |
Control stations |
(1) |
A-0e |
A-0 |
60 |
A-0 |
A-15 |
A-60 |
A-15 |
A-60 |
A-60 |
* |
A-60 |
Corridors |
(2) |
|
Ce |
B-0e |
A-0e B-0e |
B-0e |
A-60 |
A-15 |
A-60 |
A-15 A-0d |
* |
A-30 |
Accommodation spaces |
(3) |
|
|
Ce |
A-0e B-0e |
B-0e |
A-60 |
A-0 |
A-0 |
A-15 A-0d |
* |
A-30 A-0d |
Stairways |
(4) |
|
|
|
A-0e B-0e |
A-0e B-0e |
A-60 |
A-0 |
A-0 |
A-15 A-0d |
* |
A-30 |
Service spaces (low risk) |
(5) |
|
|
|
|
Ce |
A-60 |
A-0 |
A-0 |
A-0 |
* |
A-0 |
Machinery spaces of category A |
(6) |
|
|
|
|
|
* |
A-0 |
A-0 |
A-60 |
* |
A-60 |
Other machinery spaces |
(7) |
|
|
|
|
|
|
A-0b |
A-0 |
A-0 |
* |
A-0 |
Cargo spaces |
(8) |
|
|
|
|
|
|
|
* |
A-0 |
* |
A-0 |
Service spaces (high risk) |
(9) |
|
|
|
|
|
|
|
|
A-0b |
* |
A-30 |
Open decks |
(10) |
|
|
|
|
|
|
|
|
|
|
A-0 |
Special category and Ro-Ro spaces |
(11) |
|
|
|
|
|
|
|
|
|
|
A-30’ |
read:
‘Table 5.1(a)
Fire integrity of bulkheads separating adjacent spaces
Spaces |
|
(1) |
(2) |
(3) |
(4) |
(5) |
(6) |
(7) |
(8) |
(9) |
(10) |
(11) |
Control stations |
(1) |
A-0c |
A-0 |
A-60 |
A-0 |
A-15 |
A-60 |
A-15 |
A-60 |
A-60 |
* |
A-60 |
Corridors |
(2) |
|
Ce |
B-0e |
A-0a B-0e |
B-0e |
A-60 |
A-0 |
A-0 |
A-15 A-0d |
* |
A-30 |
Accommodation spaces |
(3) |
|
|
Ce |
A-0a B-0e |
B-0e |
A-60 |
A-0 |
A-0 |
A-15 A-0d |
* |
A-30 A-0d |
Stairways |
(4) |
|
|
|
A-0a B-0e |
A-0a B-0e |
A-60 |
A-0 |
A-0 |
A-15 A-0d |
* |
A-30 |
Service spaces (low risk) |
(5) |
|
|
|
|
Ce |
A-60 |
A-0 |
A-0 |
A-0 |
* |
A-0 |
Machinery spaces of category A |
(6) |
|
|
|
|
|
* |
A-0 |
A-0 |
A-60 |
* |
A-60 |
Other machinery spaces |
(7) |
|
|
|
|
|
|
A-0b |
A-0 |
A-0 |
* |
A-0 |
Cargo spaces |
(8) |
|
|
|
|
|
|
|
* |
A-0 |
* |
A-0 |
Service spaces (high risk) |
(9) |
|
|
|
|
|
|
|
|
A-0b |
* |
A-30 |
Open decks |
(10) |
|
|
|
|
|
|
|
|
|
|
A-0 |
Special category spaces |
(11) |
|
|
|
|
|
|
|
|
|
|
A-30’ |
on page 56, in Table 5.2(a) in paragraph (2), subparagraph (i) of the Annex, concerning the Annex to Directive 2009/45/EC:
for:
‘Table 5.2(a)
Fire integrity of decks separating adjacent spaces
Spaces Below↓ |
Spaces → Above |
(1) |
(2) |
(3) |
(4) |
(5) |
(6) |
(7) |
(8) |
(9) |
(10) |
(11) |
Control stations |
(1) |
A-0 |
A-0 |
A-0 |
A-0 |
A-0 |
A-60 |
A-0 |
A-0 |
A-0 |
* |
A-60 |
Corridors |
(2) |
A-0 |
* |
* |
A-0 |
* |
A-60 |
A-0 |
A-0 |
A-0 |
* |
A-30 |
Accommodation spaces |
(3) |
A-60 |
A-0 |
* |
A-0 |
* |
A-60 |
A-0 |
A-0 |
A-0 |
* |
A-30 A-0d |
Stairways |
(4) |
A-0 |
A-0 |
A-0 |
* |
A-0 |
A-60 |
A-0 |
A-0 |
A-0 |
* |
A-30 |
Service spaces (low risk) |
(5) |
A-15 |
A-0 |
A-0 |
A-0 |
* |
A-60 |
A-0 |
A-0 |
A-0 |
* |
A-0 |
Machinery spaces of category A |
(6) |
A-60 |
A-60 |
A-60 |
A-60 |
A-60 |
* |
A-60f |
A-30 |
A-60 |
* |
A-60 |
Other machinery spaces |
(7) |
A-15 |
A-0 |
A-0 |
A-0 |
A-0 |
A-0 |
* |
A-0 |
A-0 |
* |
A-0 |
Cargo spaces |
(8) |
A-60 |
A-0 |
A-0 |
A-0 |
A-0 |
A-0 |
A-0 |
* |
A-0 |
* |
A-0 |
Service spaces (high risk) |
(9) |
A-60 |
A-30 A-0d |
A-30 A-0d |
A-30 A-0d |
A-0 |
A-60 |
A-0 |
A-0 |
A-0 |
* |
A-30 |
Open decks |
(10) |
* |
* |
* |
* |
* |
* |
* |
* |
* |
— |
A-0 |
Special category and Ro-Ro spaces |
(11) |
A-60 |
A-30 |
A-30 A-0d |
A-30 |
A-0 |
A-60 |
A-0 |
A-0 |
A-30 |
A-0 |
A-30’ |
read:
‘Table 5.2(a)
Fire integrity of decks separating adjacent spaces
Space Below↓ Space Above → |
(1) |
(2) |
(3) |
(4) |
(5) |
(6) |
(7) |
(8) |
(9) |
(10) |
(11) |
|
Control stations |
(1) |
A-0 |
A-0 |
A-0 |
A-0 |
A-0 |
A-60 |
A-0 |
A-0 |
A-0 |
* |
A-60 |
Corridors |
(2) |
A-0 |
* |
* |
A-0 |
* |
A-60 |
A-0 |
A-0 |
A-0 |
* |
A-30 |
Accommodation spaces |
(3) |
A-60 |
A-0 |
* |
A-0 |
* |
A-60 |
A-0 |
A-0 |
A-0 |
* |
A-30 A-0d |
Stairways |
(4) |
A-0 |
A-0 |
A-0 |
* |
A-0 |
A-60 |
A-0 |
A-0 |
A-0 |
* |
A-30 |
Service spaces (low risk) |
(5) |
A-15 |
A-0 |
A-0 |
A-0 |
* |
A-60 |
A-0 |
A-0 |
A-0 |
* |
A-0 |
Machinery spaces of category A |
(6) |
A-60 |
A-60 |
A-60 |
A-60 |
A-60 |
* |
A-60f |
A-30 |
A-60 |
* |
A-60 |
Other machinery spaces |
(7) |
A-15 |
A-0 |
A-0 |
A-0 |
A-0 |
A-0 |
* |
A-0 |
A-0 |
* |
A-0 |
Cargo spaces |
(8) |
A-60 |
A-0 |
A-0 |
A-0 |
A-0 |
A-0 |
A-0 |
* |
A-0 |
* |
A-0 |
Service spaces (high risk) |
(9) |
A-60 |
A-30 A-0d |
A-30 A-0d |
A-30 A-0d |
A-0 |
A-60 |
A-0 |
A-0 |
A-0 |
* |
A-30 |
Open decks |
(10) |
* |
* |
* |
* |
* |
* |
* |
* |
* |
— |
A-0 |
Special category spaces |
(11) |
A-60 |
A-30 |
A-30 A-0d |
A-30 |
A-0 |
A-60 |
A-0 |
A-0 |
A-30 |
A-0 |
A-30’ |
on page 61, in paragraph (2)(l) of the Annex, concerning point 7 of the rule 9a in Annex I to Directive 2009/45/EC:
for:
‘.7 Ventilation systems for laundries in passenger ships carrying more than 36 passengers
Exhaust ducts from laundries and drying rooms of category (13) spaces as defined in Regulation II-2/B//.2.2 shall be fitted with:’,
read:
‘.7 Ventilation systems for laundries in passenger ships carrying more than 36 passengers
Exhaust ducts from laundries and drying rooms of category (13) spaces as defined in Regulation II-2/B/4.2.2 shall be fitted with:’.