ISSN 1977-091X |
||
Official Journal of the European Union |
C 206 |
|
![]() |
||
English edition |
Information and Notices |
Volume 61 |
Contents |
page |
|
|
IV Notices |
|
|
NOTICES FROM MEMBER STATES |
|
2018/C 206/01 |
EN |
|
IV Notices
NOTICES FROM MEMBER STATES
14.6.2018 |
EN |
Official Journal of the European Union |
C 206/1 |
Types of gas and the corresponding supply pressures according to Article 4(1) of Regulation (EU) 2016/426 of the European Parliament and of the Council on appliances burning gaseous fuels and repealing Directive 2009/142/EC
(This publication is based on information received by the Commission from the Member States)
(2018/C 206/01)
BELGIUM
Belgium |
||||||||||||||||
Gas Family |
2nd Family |
3rd Family |
||||||||||||||
Gas Group |
Group L |
Group H |
Group B |
Group P |
||||||||||||
|
minimum |
maximum |
minimum |
maximum |
minimum |
maximum |
minimum |
maximum |
||||||||
Gross Calorific Value (GCV) [MJ/m3] |
32,54 |
36,70 |
32,81 |
43,69 |
— |
— |
— |
— |
||||||||
Wobbe index [MJ/m3] |
41,65 |
44,49 |
46,61 |
53,91 |
87,50 (1) |
77,26 (2) |
||||||||||
Gas composition by volume in % of the total content: |
||||||||||||||||
C1 to C5 content (sum) |
||||||||||||||||
N2 + CO2 content |
||||||||||||||||
CO content |
||||||||||||||||
Unsaturated HC content |
0 |
25 |
0 |
25 |
||||||||||||
Hydrogen content |
||||||||||||||||
Information on toxic components contained in the gaseous fuel |
— |
— |
— |
— |
||||||||||||
Supply pressure: |
||||||||||||||||
|
min |
nom |
max |
min |
nom |
max |
min |
nom |
max |
min |
nom |
max |
||||
Supply pressure at the inlet of appliances [mbar] |
18 |
25 |
30 |
15 |
20 |
25 |
20 |
28 – 30 |
35 |
25 42,5 (4) |
37 50 (4) |
45 57,5 (4) |
||||
Reference conditions for Wobbe index and Gross Calorific Value (GCV) |
||||||||||||||||
Combustion reference temperature [°C] |
15 °C |
|||||||||||||||
Volume measurement reference temperature [°C] |
15 °C |
|||||||||||||||
Volume measurement reference pressure [mbar] |
1 013,25 mbar |
BULGARIA
Bulgaria |
||||||||
Gas Family |
2nd Family (5) |
3rd Family (8) |
||||||
Gas Group |
Group H |
Group B/P |
||||||
|
minimum |
maximum |
minimum |
maximum |
||||
Gross Calorific Value (GCV) [MJ/m3] |
36 |
45,7 |
94 |
— |
||||
Wobbe index [MJ/m3] |
45,7 |
54,7 |
79,94 |
86,84 |
||||
Gas composition by volume in % of the total content: |
||||||||
|
minimum |
maximum |
minimum |
maximum |
||||
C1 to C5 content (sum) |
92 |
100 |
— |
100 |
||||
N2 + CO2 content |
0 |
3 |
||||||
CO content |
||||||||
Unsaturated HC content |
||||||||
Hydrogen content |
||||||||
Information on toxic components contained in the gaseous fuel |
||||||||
Supply pressure: |
||||||||
|
min |
nom |
max |
min |
nom |
max |
||
Supply pressure at the inlet of appliances [mbar] |
17 |
20 |
25 |
30 |
30 (9)/50 |
2 000 |
||
Supply pressure at the point of delivery [mbar] |
22 |
— |
130 |
2 000 |
— |
16 000 |
||
admissible pressure loss in the end-user gas installation [mbar] |
1 |
3 |
||||||
Reference conditions for Wobbe index and Gross Calorific Value (GCV) |
||||||||
Combustion reference temperature [°C] |
15 °C |
|||||||
Volume measurement reference temperature [°C] |
15 °C |
|||||||
Volume measurement reference pressure [mbar] |
1 013,25 mbar |
CZECH REPUBLIC
Czech Republic |
||||||||
Gas Family |
2nd Family |
3rd Family |
||||||
Gas Group |
Group H |
Group B/P |
||||||
|
minimum |
maximum |
minimum |
maximum |
||||
Gross Calorific Value (GCV) [MJ/m3] |
33,8 |
42,5 |
101,8 |
134 |
||||
Wobbe index [MJ/m3] |
45,7 |
52,2 |
82,6 |
94,7 |
||||
Gas composition by volume in % of the total content: |
||||||||
C1 to C5 content (sum) |
92 – 99,5 |
100 |
||||||
N2 + CO2 content |
0,5 – 8 |
0 |
||||||
CO content |
0 |
0 |
||||||
Unsaturated HC content |
0 |
0 – 65 |
||||||
Hydrogen content |
0 |
0 |
||||||
Information on toxic components contained in the gaseous fuel |
— |
— |
||||||
Supply pressure: |
||||||||
|
min |
nom |
max |
min |
nom |
max |
||
Supply pressure at the inlet of appliances [mbar] |
17 |
20 |
25 |
25 |
30 |
35 |
||
Reference conditions for Wobbe index and Gross Calorific Value (GCV) |
||||||||
Combustion reference temperature [°C] |
15 °C |
|||||||
Volume measurement reference temperature [°C] |
15 °C |
|||||||
Volume measurement reference pressure [mbar] |
1 013,25 mbar |
DENMARK
Denmark |
||||||||||||
Gas Family |
1st Family |
2nd Family |
3rd Family |
|||||||||
Gas Group |
Group a (11) |
Group H |
Group B/P |
|||||||||
|
minimum |
maximum |
minimum |
maximum |
minimum |
maximum |
||||||
Gross Calorific Value (GCV) [MJ/m3] |
||||||||||||
Wobbe index [MJ/m3] |
22,37 |
24,84 |
48,12 (18) |
52,90 (18) |
72,90 (20) |
87,31 (20) |
||||||
Gas composition by volume in % of the total content: |
||||||||||||
C1 to C5 content (sum) |
||||||||||||
N2 + CO2 content |
||||||||||||
CO content |
||||||||||||
Unsaturated HC content |
||||||||||||
Hydrogen content |
||||||||||||
Information on toxic components contained in the gaseous fuel (14) |
0 |
H2S and COS (15): 5 mg/m3; Mercaptan (15): 5 mg/m3; S: 30 mg/m3 |
0 |
H2S and COS (15): 5 mg/m3; Mercaptan (15): 5 mg/m3; S: 30 mg/m3 |
— |
— |
||||||
Supply pressure: |
||||||||||||
|
min |
nom |
max |
min |
nom |
max |
min |
nom |
max |
|||
Supply pressure at the inlet of appliances [mbar] |
6 |
8 |
15 |
17 |
20 |
25 |
25 |
30 |
35 |
|||
Supply pressure at the point of delivery [mbar] |
30 |
|||||||||||
Admissible pressure loss in the end-user gas installation [mbar] |
2 |
2 |
2 |
|||||||||
Reference conditions for Wobbe index and Gross Calorific Value (GCV) |
||||||||||||
Combustion reference temperature [°C] |
15 °C |
|||||||||||
Volume measurement reference temperature [°C] |
15 °C |
|||||||||||
Volume measurement reference pressure [mbar] |
1,013 bar |
GERMANY
Germany |
||||||||||||||||
Gas Family |
2nd |
3rd |
||||||||||||||
Gas Group |
Group H |
Group L |
Group P |
Group B |
||||||||||||
|
Min |
Max |
Min |
Max |
Min |
Max |
Min |
Max |
||||||||
Gross calorific value (GCV) [MJ/m3] |
34,5 |
44,7 |
28,7 |
38,6 |
101,2 (24) |
133,8 (24) |
||||||||||
Wobbe index [MJ/m3] |
46,50 (21) |
53,60 |
37,60 (22) |
44,40 |
72,90 (25) |
87,30 (25) |
81,80 |
87,30 |
||||||||
Gas composition by volume in % of the total content: |
||||||||||||||||
C1 to C5 content (sum) |
— |
100 |
— |
100 |
— |
100 |
— |
100 |
||||||||
N2 + CO2 content |
2,5 |
4 |
|
— |
|
— |
|
— |
||||||||
CO content |
— |
— |
— |
— |
||||||||||||
Unsaturated HC content |
— |
— |
10 % |
10 % |
||||||||||||
Hydrogen content |
0 |
0,2 – 10 |
0 |
0,2 – 10 |
0 |
0,2 (26) |
0 |
0,2 (26) |
||||||||
Information on toxic components contained in the gaseous fuel |
— |
H2S and COS: 5 mg/m3 |
— |
H2S and COS: 5 mg/m3 |
— |
H2S: technically free / S from COS: 5 mg/kg |
— |
H2S: technically free/ S from COS: 5 mg/kg |
||||||||
Supply pressure: |
||||||||||||||||
|
Minimum |
Nominal |
Maximum |
Minimum |
Nominal |
Maximum |
Minimum |
Nominal |
Maximum |
Minimum |
Nominal |
Maximum |
||||
Supply pressure at the inlet of appliances [mbar]: |
18 |
20 |
25 |
18 |
20 |
25 |
42,5 |
50 |
57,5 |
42,5 |
50 |
57,5 |
||||
Supply pressure at the point of delivery [mbar] |
20 |
23 |
25,3 |
20 |
23 |
25,3 |
42,5 |
50 |
57,5 |
42,5 |
50 |
57,5 |
||||
Admissible pressure loss in the end-user gas installation [mbar] |
3 (23) |
3 (23) |
5 (23) |
5 (23) |
||||||||||||
Reference conditions for Wobbe index and gross calorific value: |
||||||||||||||||
Combustion reference temperature [°C] |
15 °C |
|||||||||||||||
Volume measurement reference temperature [°C] |
15 °C |
|||||||||||||||
Volume measurement reference pressure [mbar] |
1 013,25 mbar |
SPAIN
Spain |
||||||||||||
Gas family |
Second |
Third |
||||||||||
Gas group |
Group H |
Group P |
Group B |
|||||||||
|
minimum |
maximum |
minimum |
maximum |
minimum |
maximum |
||||||
Gross calorific value (GCV) [MJ/m3] |
31,86 |
45,28 |
95,65 |
101,68 |
119,78 |
126,1 |
||||||
Wobbe index [MJ/m3] |
45,66 |
54,76 |
76,61 |
78,94 |
85,23 |
87,43 |
||||||
Gas composition by volume in % of the total content: |
||||||||||||
|
||||||||||||
C1 to C5 content and traces of C6+ in % (sum) |
100 (29) |
— |
— |
— |
— |
|||||||
C2 content in % |
— |
— |
0 |
2,5 |
0 |
2 |
||||||
C3 content in % |
— |
— |
80 |
100 |
0 |
20 |
||||||
C4 content in % |
— |
— |
0 |
20 |
80 |
100 |
||||||
C5 content in % |
— |
— |
0 |
1,5 |
0 |
1,5 |
||||||
N2 + CO2 content in % |
0 |
2,5 (30) |
— |
— |
— |
— |
||||||
CO content in % |
0 (31) 0 (32) |
0 (31) 2 (32) |
— |
— |
— |
— |
||||||
Unsaturated HC content in % |
0 (37) 0 ppm (38) |
35 (37) 1 000 ppm (38) |
0 (37) 0 ppm (38) |
20 (37) 1 000 ppm (38) |
||||||||
Hydrogen content in % |
0 (31) 0 (32) |
0 (31) 5 (32) |
— |
— |
— |
— |
||||||
Information on toxic components contained in the gaseous fuel: |
||||||||||||
|
||||||||||||
Supply pressure: |
||||||||||||
|
minimum (35) |
nominal (35) |
maximum (35) |
minimum (35) |
nominal (35) |
maximum (35) |
minimum (35) |
nominal (35) |
maximum (35) |
|||
Supply pressure at the inlet of appliances [mbar] |
17 |
20 |
25 |
20 (40) 42,5 (41) 25 (42) 20/25/42,5 (43) |
(28–30) 37 (40) 50 (41) 37 (42) 29/37/50 (43) |
45 (40) 57,5 (41) 45 (42) 35/45/57,5 (43) |
20 (40) 20 (44) 20/25/42,5 (43) |
(28–30) 37 (40) 29 (44) 29/37/50 (43) |
45 (40) 35 (44) 35/45/57,5 (43) |
|||
The reference conditions for Wobbe index and gross calorific value shall be the following: |
||||||||||||
Combustion reference temperature [°C] |
15 °C |
|||||||||||
Volume measurement reference temperature [°C] |
15 °C |
|||||||||||
Volume measurement reference pressure [mbar] |
1,01325 bar |
FRANCE
France [Table I] |
||||||||||||||||
Gas Family |
1st Family |
2nd Family |
||||||||||||||
Gas Group |
Group c |
|
Group H |
Group L |
||||||||||||
|
min |
max |
min |
max |
min |
max |
min |
max |
||||||||
Gross Calorific Value (GCV) [MJ/m3] |
24,27 (45) |
25,93 (45) |
37,16 |
44,45 |
32,99 |
36,47 |
||||||||||
Wobbe index [MJ/m3] |
26,5 (45) |
23,9 (45) |
46,55 |
53,58 |
40,99 |
44,57 |
||||||||||
Gas composition by volume in % of the total content: |
||||||||||||||||
C1 to C5 content (sum) |
~ 21 |
|||||||||||||||
N2 + CO2 content |
0 |
CO2 < 3,5 CO2 < 2,5 (47) |
CO2 < 11,7 CO2 < 2,5 (47) |
|||||||||||||
CO content |
0 |
< 2 |
< 2 |
|||||||||||||
Unsaturated HC content |
0 |
|||||||||||||||
Hydrogen content |
0 |
< 6 |
< 6 |
|||||||||||||
Information on toxic components contained in the gaseous fuel |
Hg < 1 mg/m3 Cl < 1 mg/ m3 F < 10 mg/m3 |
Hg < 1 mg/m3 Cl < 1 mg/ m3 F < 10 mg/m3 |
||||||||||||||
Supply pressure: |
||||||||||||||||
|
min |
nom |
max |
min |
nom |
max |
min |
nom |
max |
min |
nom |
max |
||||
Supply pressure at the inlet of appliances [mbar] |
6 |
8 |
15 |
6 |
8 |
15 |
17 |
20 |
25 |
20 |
25 |
30 |
||||
Supply pressure at the point of delivery [mbar] |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
||||
Admissible pressure loss in the end-user gas installation [mbar] |
— |
— |
— |
— |
||||||||||||
Reference conditions for Wobbe index and Gross Calorific Value (GCV) |
||||||||||||||||
Combustion reference temperature [°C] |
15 °C |
|||||||||||||||
Volume measurement reference temperature [°C] |
15 °C |
|||||||||||||||
Volume measurement reference pressure [mbar] |
1 013,25 mbar |
France [Table II] |
||||||||||||
Gas Family |
3rd Family |
|||||||||||
Gas Group |
Group P |
Group B |
Group B/P |
|||||||||
|
min |
max |
min |
max |
min |
max |
||||||
Gross Calorific Value (GCV) [MJ/m3] |
97 |
104 |
124 |
134 |
97 |
134 |
||||||
Wobbe index [MJ/m3] |
79 |
82 |
89 |
93 |
75,46 |
85,22 |
||||||
Gas composition by volume in % of the total content: |
||||||||||||
C1 to C5 content (sum) |
99 |
100 |
99 |
100 |
99 |
100 |
||||||
N2 + CO2 content |
< 0,5 |
< 0,5 |
< 0,5 |
|||||||||
CO content |
< 0,5 |
< 0,5 |
< 0,5 |
|||||||||
Unsaturated HC content |
0,05 |
50 |
0,05 |
50 |
0,05 |
50 |
||||||
Hydrogen content |
< 0,5 |
< 0,5 |
< 0,5 |
|||||||||
Information on toxic components contained in the gaseous fuel |
0 |
0 |
0 |
|||||||||
Supply pressure: |
||||||||||||
|
min |
nom |
max |
min |
nom |
max |
min |
nom |
max |
|||
Supply pressure at the inlet of appliances [mbar] |
25 42,5 (48) 100 (48) |
37 50 (48) 148 (48) |
45 57,5 (48) 180 (48) |
20 60 (48) |
28–30 112 (48) |
35 140 (48) |
25 |
28–30 |
35 |
|||
Supply pressure at the point of delivery [mbar] |
— |
— |
— |
— |
— |
— |
— |
— |
— |
|||
Admissible pressure loss in the end-user gas installation [mbar] |
— |
— |
— |
|||||||||
Reference conditions for Wobbe index and Gross Calorific Value (GCV) |
||||||||||||
Combustion reference temperature [°C] |
15 °C |
|||||||||||
Volume measurement reference temperature [°C] |
15 °C |
|||||||||||
Volume measurement reference pressure [mbar] |
1 013,25 mbar |
CROATIA
Croatia |
||||||||||||
Gas Family |
2nd Family |
3rd Family |
||||||||||
Gas Group |
Group H |
Group B/P |
Group P |
|||||||||
|
minimum |
maximum |
minimum |
maximum |
minimum |
maximum |
||||||
Gross Calorific Value (GCV) [MJ/m3] |
37 |
45,9 |
97,99 |
123,8 |
97,99 |
123,8 |
||||||
Wobbe index [MJ/m3] |
45,9 |
56,92 |
72,5 |
91,58 |
72,5 |
91,58 |
||||||
Gas composition by volume in % of the total content: |
||||||||||||
C1 to C5 content (sum) |
85 |
98 |
95 |
99 |
95 |
99 |
||||||
N2 + CO2 content |
0 |
7 |
0 |
9,8 |
— |
|||||||
CO content |
— |
— |
— |
— |
||||||||
Unsaturated HC content |
0 |
— |
— |
— |
||||||||
hydrogen content |
0 |
0 |
0 |
|||||||||
Information on toxic components contained in the gaseous fuel |
||||||||||||
H2S+COS [mg/m3] |
0 |
5 |
0 |
13,9 |
— |
|||||||
S [mg/m3] |
0 |
30 |
0 |
38 |
— |
|||||||
*RHS toxins [mg/m3] |
— |
6 (49) |
— |
— |
||||||||
Supply pressure: |
||||||||||||
|
min |
nom |
max |
min |
nom |
max |
min |
nom |
max |
|||
Supply pressure at the point of delivery [mbar] |
22 |
22 |
50 |
22 |
30 |
37 |
22 |
37 |
50 |
|||
Admissible pressure loss in the end-user gas installation [mbar] |
5 |
0 |
8 |
— |
0 |
— |
— |
0 |
— |
|||
Reference conditions for Wobbe index and Gross Calorific Value (GCV) |
||||||||||||
Combustion reference temperature [°C] |
15 °C |
|||||||||||
Volume measurement reference temperature [°C] |
15 °C |
|||||||||||
Volume measurement reference pressure [mbar] |
1 013,25 mbar |
CYPRUS
Cyprus |
||||
Gas Family |
3rd Family |
|||
Gas Group |
|
|||
|
minimum |
maximum |
||
Gross Calorific Value (GCV) [MJ/m3] |
||||
Wobbe index [MJ/m3] |
85,9 (51) 80,2 (52) |
85,9 (51) 80,2 (52) |
||
Gas composition by volume in % of the total content (53): |
||||
C1 |
— |
|||
C2 |
1,0 |
1,0 |
||
C3 |
38,2 |
38,2 |
||
C4 |
60,1 |
60,1 |
||
C5 |
0,7 |
0,7 |
||
N2 + CO2 content |
||||
CO content |
||||
Unsaturated HC content |
0,03 |
42,78 |
||
Hydrogen content |
||||
Information on toxic components contained in the gaseous fuel |
||||
Supply pressure: |
||||
|
min |
nom |
max |
|
Supply pressure at the inlet of appliances (54) [mbar] |
— |
— |
50 (55) 100 (56) 100 (57) 300 (58) 50 (59) 100 (60) 50 (61) 300 (62) |
|
Supply pressure at the point of delivery [mbar] |
||||
admissible pressure loss in the end-user gas installation [mbar] |
||||
Reference conditions for Wobbe index and Gross Calorific Value (GCV) |
||||
Combustion reference temperature [°C] |
15 °C |
|||
Volume measurement reference temperature [°C] |
15 °C |
|||
Volume measurement reference pressure [mbar] |
1 013,25 mbar |
LATVIA
Latvia |
||||||||
Gas Family |
2nd Family |
3rd Family |
||||||
Gas Group |
Group H |
Group B/P |
||||||
|
minimum |
maximum |
minimum |
maximum |
||||
Gross Calorific Value (GCV) [MJ/m3] |
31,82 |
34,87 |
101,27 |
110,02 |
||||
Wobbe index [MJ/m3] |
47,02 |
51,98 |
76,7 |
83,3 |
||||
Gas composition by volume in % of the total content: |
||||||||
C1 to C5 content (sum) |
96,5 |
98,5 |
98,8 |
|||||
N2 + CO2 content |
~ 1 |
0 |
1 |
|||||
CO content |
~ 0,36 |
0 |
1 |
|||||
Unsaturated HC content |
0,06 |
0,07 |
0 |
1 |
||||
Hydrogen content |
0,06 |
0,07 |
0 |
1 |
||||
Information on toxic components contained in the gaseous fuel |
— |
— |
||||||
Supply pressure: |
||||||||
|
min |
nom |
max |
min |
nom |
max |
||
Supply pressure at the inlet of appliances [mbar] |
17 |
20 |
25 |
20 |
30 |
45 |
||
Supply pressure at the point of delivery [mbar] |
17 |
20 |
25 |
20 |
30 |
45 |
||
Admissible pressure loss in the end-user gas installation [mbar] |
0 |
0,5 |
1 |
0 |
0,5 |
1 |
||
Reference conditions for Wobbe index and Gross Calorific Value (GCV) |
||||||||
Combustion reference temperature [°C] |
20 °C (63) |
15 °C |
||||||
Volume measurement reference temperature [°C] |
20 °C (63) |
15 °C |
||||||
Volume measurement reference pressure [mbar] |
1 013,25 mbar |
1 013,25 mbar |
LITHUANIA
Lithuania |
||||
Gas Family |
2nd Family |
|||
Gas Group |
Group H |
|||
|
minimum |
maximum |
||
Gross Calorific Value (GCV) [MJ/m3] |
34,56 |
— |
||
Wobbe index [MJ/m3] |
47,016 |
51,984 |
||
Gas composition by volume in % of the total content: |
||||
C1 to C5 content (sum) |
90 |
— |
||
N2 + CO2 content |
— |
5,5 |
||
CO content |
||||
Unsaturated HC content |
— |
— |
||
Hydrogen content |
— |
2 |
||
Information on toxic components contained in the gaseous fuel |
prohibited |
|||
Supply pressure: |
||||
|
min |
nom |
max |
|
Supply pressure at the inlet of appliances [mbar] |
21 |
— |
30 |
|
Supply pressure at the point of delivery [mbar] |
— |
|||
Admissible pressure loss in the end-user gas installation [mbar] |
— |
|||
Reference conditions for Wobbe index and Gross Calorific Value (GCV) |
||||
Combustion reference temperature [°C] |
25 °C |
|||
Volume measurement reference temperature [°C] |
20 °C |
|||
Volume measurement reference pressure [mbar] |
1 013,25 mbar |
LUXEMBOURG
Luxembourg |
||||
Gas Family |
2nd Family |
|||
Gas Group |
Group H |
|||
|
minimum |
maximum |
||
Gross Calorific Value (GCV) [MJ/m3] |
36,5 |
47,2 |
||
Wobbe index [MJ/m3] |
49,0 |
56,5 |
||
Gas composition by volume in % of the total content: |
||||
C1 to C5 content (sum) |
> 86 |
99 |
||
N2 + CO2 content |
— |
4,5 |
||
CO content |
||||
Unsaturated HC content |
||||
Hydrogen content |
||||
Information on toxic components contained in the gaseous fuel |
— |
|||
Supply pressure: |
||||
|
min |
nom |
max |
|
Supply pressure at the inlet of appliances [mbar] |
17 (15) (66) |
20 |
25 (67) |
|
Supply pressure at the point of delivery (68) [mbar] |
19,7 |
20 |
24,3 |
|
Admissible pressure loss in the end-user gas installation [mbar] |
— |
— |
1,6 |
|
Reference conditions for Wobbe index and Gross Calorific Value (GCV) |
||||
Combustion reference temperature [°C] |
15 °C |
|||
Volume measurement reference temperature [°C] |
15 °C |
|||
Volume measurement reference pressure [mbar] |
1 013,25 mbar |
THE NETHERLANDS
The Netherlands (1) |
||||||||||||
Gas family |
First |
Second |
Third |
|||||||||
Gas group |
|
|
|
|||||||||
|
Minimum |
Maximum |
Minimum |
Maximum |
Minimum |
Maximum |
||||||
Gross calorific value (GCV) [MJ/m3] |
|
|
|
|
|
|
||||||
Wobbe index (2) [MJ/m3] |
|
|
H gas network: 44,59 G gas network, G conditions: 41,23 G gas network, G+ conditions: 41,23 |
H gas network: 52,84 G gas network, G conditions: 42,13 G gas network, G+ conditions: 42,98 |
|
|
||||||
Gas composition by volume in % of the total content: |
||||||||||||
C1 to C5 content (sum) (3) |
|
|
|
|
|
|
||||||
N2 + CO2 content |
|
|
|
H gas network: ≤ 3,2 mol % (Oude Pekela subsystem), ≤ 2,5 mol % (the rest of the Netherlands) G gas network, G and G+ conditions: ≤ 10,3 mol % (RTL and RNB networks), ≤ 8 mol % (HTL in the provinces of North Holland, South Holland, Utrecht and Flevoland), ≤ 3 mol % (HTL in the rest of the Netherlands) (4). |
|
|
||||||
CO content |
|
|
|
H gas network: ≤ 1,5 mol % (refinery gas system); ≤ 2 900 mg/m3(n) (the rest of the Netherlands) G gas network: G and G+ conditions: ≤ 2 900 mg/m3(n); for E conditions no value has yet been determined. |
|
|
||||||
Unsaturated HC content |
|
|
|
See Gas Quality Order. |
|
|
||||||
Hydrogen content |
|
|
|
H gas network: ≤ 40 mol % (refinery gas system); ≤ 0,02 mol % (the rest of the Netherlands) G gas network: G and G+ conditions: ≤ 0,02 mol % (in RTL and HTL); ≤ 0,5 mol % (in RNB network) For E conditions: no value has yet been determined. |
|
|
||||||
Information on toxic components contained in the gaseous fuel |
|
|
|
See Gas Quality Order. The REACH Regulation also applies. |
|
|
||||||
Supply pressure: (5) |
||||||||||||
Gas family |
First |
Second |
Third |
|||||||||
|
Minimum |
Nominal |
Maximum |
Minimum |
Nominal |
Maximum |
Minimum |
Nominal |
Maximum |
|||
Supply pressure at the inlet of appliances [mbar] |
|
|
|
H gas network: no specific expectations G gas network: G and G+ conditions: 20 mbar, E conditions: minimum 17 mbar |
H gas network: no specific expectations G gas network: G and G+ conditions: nominal 25 mbar (6), E conditions: nominal 20 mbar |
H gas network: no specific expectations G gas network: G and G+ conditions: maximum mbar: 30 mbar, E conditions: maximum 25 mbar |
propane (1): 25 propane (2): 25 propane (3): 42,5 propane/butane: 25 |
propane (1): 30 propane (2): 37 propane (3): 50 propane/butane: 30 |
propane (1): 35 propane (2): 45 propane (3): 57,5 propane/butane: 35 |
|||
Supply pressure at the point of delivery [mbar] |
|
|
|
|
|
|
|
|
|
|||
Admissible pressure loss in the end-user gas installation [mbar] |
|
|
|
|
|
|
|
|
|
|||
The reference conditions for the Wobbe index and the gross calorific value |
||||||||||||
Combustion reference temperature [°C] |
15 |
|||||||||||
Volume measurement reference temperature: [°C] |
15 |
|||||||||||
Volume measurement reference pressure [mbar] |
1 013,25 |
AUSTRIA
Austria |
||||
Gas family |
Second |
|||
Gas group |
Group H |
|||
|
Minimum |
Maximum |
||
GCV: Gross Calorific Value [MJ/m3] |
36,5 |
43,6 |
||
Wobbe Index [MJ/m3] |
45,3 |
53,5 |
||
Gas composition |
||||
C1 to C5, content (total) [Mol %] |
89 |
100 |
||
N2 + CO2, content [Mol %] |
0 |
7 |
||
CO, content [Mol %] |
0 |
0 |
||
Unsaturated hydrocarbons, content [Mol %] |
0 |
0 |
||
Hydrogen, content [Mol %] |
0 |
4 |
||
Information on the toxic components contained in the gaseous fuel |
Technically free |
|||
Supply pressure: |
||||
|
Minimum |
Nominal value |
Maximum |
|
Supply pressure at the inlet of appliances in mbar: |
18 |
20 |
25 |
|
Supply pressure at the point of delivery in mbar: |
In accordance with the contract between the gas network operator and the customer |
|||
Admissible pressure loss in the end-user gas installation in mbar: |
— |
|||
Reference conditions for Wobbe Index and Gross Calorific Value: |
||||
Combustion reference temperature [°C] |
15 °C |
|||
Volume measurement reference temperature [°C] |
15 °C |
|||
Volume measurement reference pressure [mbar] |
1 013,25 mbar |
POLAND
Poland |
|||||||||||||||||||||
Gas Family |
2nd Family |
Gases combined with 2nd Family |
3rd Family (69) |
||||||||||||||||||
Gas Group |
Group H |
Group Lm |
Group Ln |
Group Ls |
Group Lw |
— |
|||||||||||||||
|
minimum |
maximum |
minimum |
maximum |
minimum |
maximum |
minimum |
maximum |
minimum |
maximum |
|||||||||||
Gross Calorific Value (GCV) [MJ/m3] |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
|||||||||||
Wobbe index [MJ/m3] (70) |
45,0 |
56,9 |
23,0 |
27,0 |
27,0 |
32,5 |
32,5 |
37,5 |
37,5 |
45,0 |
|||||||||||
Gas composition by volume in % of the total content: |
|||||||||||||||||||||
C1 to C5 content (sum) |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
||||||||||
N2 + CO2 content |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
||||||||||
CO content |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
||||||||||
Unsaturated HC content |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
||||||||||
Hydrogen content |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
||||||||||
Information on toxic components contained in the gaseous fuel |
— |
— |
— |
— |
— |
— |
|||||||||||||||
Supply pressure: |
|||||||||||||||||||||
|
min |
nom |
max |
min |
nom |
max |
min |
nom |
max |
min |
nom |
max |
min |
nom |
max |
|
|||||
Supply pressure at the inlet of appliances [mbar] |
14 |
20 |
25 |
6 |
8 |
11 |
10,5 |
13 |
16 |
10,5 |
13 |
16 |
17,5 |
20 |
23 |
— |
|||||
Supply pressure at the point of delivery [mbar] |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
|||||
Admissible pressure loss in the end-user gas installation [mbar] |
— |
— |
— |
— |
— |
— |
|||||||||||||||
Reference conditions for Wobbe index and Gross Calorific Value (GCV) |
|||||||||||||||||||||
Combustion reference temperature [°C] |
25 °C |
||||||||||||||||||||
Volume measurement reference temperature [°C] |
0 °C |
||||||||||||||||||||
Volume measurement reference pressure [mbar] |
1 013,25 mbar |
PORTUGAL
Portugal |
||||||||||||
Gas Family |
2nd Family |
3rd Family |
||||||||||
Gas Group |
Group H |
Group P |
Group B |
|||||||||
|
minimum |
maximum |
minimum |
maximum |
minimum |
maximum |
||||||
Gross Calorific Value (GCV) [MJ/m3] |
35,88 (71) |
48,25 (71) |
||||||||||
Wobbe index [MJ/m3] |
48,17 (71) |
57,66 (71) |
70,44 |
77,01 |
83,26 |
87,3 |
||||||
Gas composition by volume in % of the total content: |
||||||||||||
C1 to C5 content (sum) |
90 (72) |
15,1 (72) |
80 (72) |
23 (72) |
||||||||
N2 + CO2 content |
||||||||||||
CO content |
||||||||||||
Unsaturated HC content |
||||||||||||
Hydrogen content |
||||||||||||
Information on toxic components contained in the gaseous fuel |
S (72): 50 mg/kg; NH3 (72): 1 ppmv; H2S < 4 mg/m3 |
S (72): 50 mg/kg; NH3 (72): 1 ppmv; H2S < 4 mg/m3 |
||||||||||
Supply pressure: |
||||||||||||
|
min |
nom |
max |
min |
nom |
max |
min |
nom |
max |
|||
Supply pressure at the inlet of appliances [mbar] |
|
20 |
|
|
37 (74) |
|
|
30 (74) |
|
|||
Supply pressure at the point of delivery [mbar] |
|
21 |
|
35,5 |
|
37 |
28,5 |
|
30 |
|||
Admissible pressure loss in the end-user gas installation [mbar] |
1,5 |
1,5 |
1,5 |
|||||||||
Reference conditions for Wobbe index and Gross Calorific Value (GCV) |
||||||||||||
Combustion reference temperature [°C] |
— |
25 °C (75) |
||||||||||
Volume measurement reference temperature [°C] |
0 °C (72) |
0 °C (75) |
||||||||||
Volume measurement reference pressure [mbar] |
Pabs = 1,013 bar (72) |
Pabs = 1,01325 bar (75) |
FINLAND
Finland |
||||||
Gas Family |
2nd Family |
3rd Family |
||||
Gas Group |
Group H |
Group B/P |
||||
|
min |
nom |
maxi |
min |
nom |
max |
Gross Calorific Value (GCV) [MJ/m3] |
36,67 |
38,25 |
39,23 |
88,5 |
— |
125,8 |
Wobbe index [MJ/m3] |
47,0 |
50,57 |
54,0 |
72,9 |
— |
87,3 |
Gas composition by volume in % of the total content: |
||||||
C1 to C5 content (sum) |
95 |
99,19 |
100 |
99 |
— |
100 |
N2 + CO2 content |
0 |
0,80 |
4,5 |
— |
— |
0,04 |
CO content |
0 |
0 |
0 |
— |
— |
0,02 |
Unsaturated HC content |
0 |
0 |
0 |
0 |
0 |
0,01 |
Hydrogen content |
0 |
0 |
0 |
— |
— |
— |
Information on toxic components contained in the gaseous fuel |
0 |
0 |
H2S: 0,00025 vol-% (5 mg/ m3) |
— |
— |
1,3 butadiene: 0,01 |
Supply pressure: |
||||||
|
min |
nom |
max |
min |
nom |
max |
Supply pressure at the inlet of appliances [mbar] |
17 |
20 |
25 |
25 |
30 |
35 |
Supply pressure at the point of delivery [mbar] |
— |
— |
— |
— |
— |
— |
Admissible pressure loss in the end-user gas installation [mbar] |
— |
— |
3,5 (76) 10 % (77) |
— |
— |
— |
Reference conditions for Wobbe index and Gross Calorific Value (GCV) |
||||||
Combustion reference temperature [°C] |
15 °C |
|||||
Volume measurement reference temperature [°C] |
15 °C |
|||||
Volume measurement reference pressure [mbar] |
1 013,25 mbar |
SWEDEN
Sweden |
||||||||||||||||
Gas Family |
1st Family |
2nd Family |
|
3rd Family |
||||||||||||
Gas Group |
|
Group H |
|
|||||||||||||
|
min |
max |
min |
max |
min |
max |
min |
max |
||||||||
Gross Calorific Value (GCV) [MJ/m3] |
20,9 |
23,0 |
36,47 |
46,69 |
36 |
39,6 |
95,75 (79) |
|||||||||
Wobbe index [MJ/m3] |
23,2 |
25,7 |
48,96 |
55,8 |
45,5 |
50,2 |
70,78 |
77,02 |
||||||||
Gas composition by volume in % of the total content: |
||||||||||||||||
C1 to C5 content (sum) |
52 |
57 |
88,92 |
99,48 |
96 |
98 |
— |
99,9 |
||||||||
N2 + CO2 content |
35 |
38 |
0,50 |
2,48 |
0 |
4 |
0 |
|||||||||
CO content |
0 |
0 |
0 |
0 |
||||||||||||
Unsaturated HC content |
0 |
0 |
0 |
0 |
||||||||||||
Hydrogen content |
0 |
0,5 |
0 |
0 |
1 |
0 |
||||||||||
Information on toxic components contained in the gaseous fuel |
— |
— |
— |
— |
||||||||||||
Supply pressure: |
||||||||||||||||
|
min |
nom |
max |
min |
nom |
max |
min |
nom |
max |
min |
nom |
max |
||||
Supply pressure at the inlet of appliances [mbar] |
6 |
12 |
15 |
17 |
20 |
25 |
17 |
20 |
25 |
25 |
30 |
35 |
||||
Supply pressure at the point of delivery [mbar] |
10 |
8 |
15 |
— |
— |
— |
80 |
100 |
100 |
— |
— |
— |
||||
admissible pressure loss in the end-user gas installation [mbar] |
2 |
— |
2 |
— |
||||||||||||
Reference conditions for Wobbe index and Gross Calorific Value (GCV) |
||||||||||||||||
Combustion reference temperature [°C] |
15 °C |
|||||||||||||||
Volume measurement reference temperature [°C] |
15 °C |
|||||||||||||||
Volume measurement reference pressure [mbar] |
1 013,25 mbar |
UNITED KINGDOM
United Kingdom |
||||||||||||
Gas Family |
2nd Family |
3rd Family |
||||||||||
Gas Group |
Group H |
Group P |
Group B |
|||||||||
|
min |
max |
min |
max |
min |
max |
||||||
Gross Calorific Value (GCV) [MJ/m3] |
88,2 |
100,1 |
121,3 |
126,7 |
||||||||
Wobbe index [MJ/m3] |
47,20 (81) |
51,41 (81) |
72,7 |
78,5 |
85,7 |
87,7 |
||||||
Gas composition by volume in % of the total content: |
||||||||||||
C1 to C5 content (sum) |
100 |
100 |
100 |
100 |
||||||||
N2 + CO2 content |
— |
N2 (82) CO2: 2,5 mol % (83) |
NIL |
NIL |
||||||||
CO content |
NIL |
NIL |
||||||||||
Unsaturated HC content |
0 |
100 |
0 |
100 |
||||||||
Hydrogen content |
— |
0,1 mol % |
NIL |
NIL |
||||||||
Information on toxic components contained in the gaseous fuel |
H2S limit ≤ 5mg/m3 |
|||||||||||
Supply pressure: |
||||||||||||
|
min |
nom |
max |
min |
nom |
max |
min |
nom |
max |
|||
Supply pressure at the inlet of appliances (85) [mbar] |
— |
— |
— |
25 25 (86) |
37 29 (86) |
45 35 (86) |
20 25 (86) |
29 29 (86) |
35 35 (86) |
|||
Supply pressure at the point of delivery [mbar] |
18,5 |
— |
22 |
32 (87) 27 (88) 30 (90) 30 (91) |
37 (87) 37 (88) 37 (90) 30 (91) |
45 (87) 45 (88) 45 (90) 35 (91) |
22 (89) 30 (91) |
29 (89) 30 (91) |
35 (89) 35 (91) |
|||
admissible pressure loss in the end-user gas installation [mbar] |
— |
— |
1 (92) |
— |
— |
5 (95) |
— |
— |
0,5 (93) 2 (94) 5 (95) |
|||
Reference conditions for Wobbe index and Gross Calorific Value (GCV) |
||||||||||||
Combustion reference temperature [°C] |
15 °C |
|||||||||||
Volume measurement reference temperature [°C] |
15 °C |
|||||||||||
Volume measurement reference pressure [mbar] |
1 013,25 mbar |
(1) Commercial butane as described in the Royal Decree of 20 December 1999;
(2) Commercial propane as described in the Royal Decree of 20 December 1999;
(3) Not regulated;
(4) Only for certain non-domestic appliances (catering etc.).
(5) Source: Bulgarian Natural Gas Association;
(6) No data available;
(7) At 130 mbar supply pressure at delivery point pressure losses are not specified. Required flow rate shall be below 6 m/s;
(8) Source: Bulgarian Petrol and Gas Association;
(9) Indicated value corresponds to the traditionally distributed pressure regulators in Bulgaria. Nominal value of 50 mbar is also allowable as an option;
(10) Depends on the installation. The question is not relevant.
(11) Town gas in Denmark is composed of a mixture of natural gas and air;
(12) Gross calorific value is not regulated by the Danish Safety technology Authority;
(13) Not regulated;
(14) The values listed are all without sulphur from odorant;
(15) Measured as sulphur;
(16) Supply pressure at the point of delivery is decided by the local town gas distributors;
(17) Gross calorific value is not regulated by the Danish Safety Technology Authority but by regulation the relative density of natural gas shall be within 0,555 and 0,7;
(18) Abnormal supply conditions: provided that the Danish Safety Technology Authority has approved a special contingency plan allowing supply in an abnormal supply range, the Wobbe index can be between 47,44 and 48,12 MJ/m3;
(19) Supply pressure at the point of delivery is decided by the local natural gas distributors;
(20) Gases in the 3rd family must always comply with the international standard ISO 9162.
(21) Group H: For suitable gas appliances (e.g. appliance category I2E), shortfalls in the Wobbe index down to WS,n = 43,2 MJ/m3 (12,0 kWh/m3) can be tolerated for limited periods of time in order to avoid supply shortages, with the appliance setting remaining unchanged at WS,n = 54,0 MJ/m3 (15,0 kWh/m3). (40,95 MJ/m3 (15 °C));
(22) Group L: For suitable gas appliances (e.g. appliance category I2ELL), shortfalls in the Wobbe index down to WS,n = 36,0 MJ/m3 (10,0 kWh/m3) can be tolerated for limited periods of time in order to use natural gases which are rich in inert gases, with the appliance setting remaining unchanged at WS,n = 44,6 MJ/m3 (12,4 kWh/m3). (34,13 MJ/ m3 (15 °C ));
(23) Domestic or similar use only; deviations possible for commerce or industry;
(24) Nominal;
(25) Only from stationary tank;
(26) Hydrogen, nitrogen, oxygen and methane.
(27) Based on the Detailed Protocol of the standards for the technical management of the gas system PD-01 ‘Measurement, Quality and Odorisation of Gas’;
(28) Undefined minimum, which allows for compliance with the minima GCV and WI;
(29) Must not exceed that which allows for compliance with the maxima GCV and WI;
(30) For CO2. For mixtures, which allows for compliance with the minima GCV and WI;
(31) In natural gas;
(32) In gases of unconventional origin (Table 4 of PD-01);
(33) Not defined. Allows for compliance with a maximum dew point of + 5°C between 1 and 70 bar;
(34) Natural gas must not contain toxic components;
(35) In the case of appliances intended for non-domestic use, the pressure may vary depending on the operating mode of the appliance (all-nothing, all-little-nothing or modulating), in line with the indications in the manufacturer’s instruction manual;
(36) Composition of the gas legally defined in Royal Decree 61/2006 of 31 January 2006 laying down the specifications for petrol, diesel and liquefied petroleum gas and regulating the use of certain biofuels;
(37) Total olefins;
(38) Diolefins + Acetylene;
(39) LPG must not contain toxic components;
(40) Appliance category 3+;
(41) Appliance category 3P(50);
(42) Appliance category 3P(37);
(43) Appliance category 3R;
(44) Appliance category 3B.
(45) Average value;
(46) Not available;
(47) If connected to a transmission network;
(48) Only for some non-domestic appliances.
(49) This data is an experiential figure defined as a limit value from the practical experience. The standard on the quality of gas fuels does not contain references to RHS toxins [mg/m3].
(50) Not specified;
(51) LPG with 100 % Butane;
(52) LPG with 60 % Propane and 40 % butane;
(53) Average LPG content by volume for 2017;
(54) The maximum allowable operating pressure of LPG pipes within a building, depending on its usage, should not exceed the limits provided, unless the gas burning devices have been certified by the manufacturer for higher pressures and after inspection by an Inspector of the Department of Labour Inspection;
(55) Gas burning devices with connection pressure up to 50 mbar;
(56) Central heating boiler rooms;
(57) Large building boiler rooms, hospitals, hotels, etc. of total supply up to 300 kg/h;
(58) Large building boiler rooms, hospitals, hotels, etc. of total supply exceeding 300 kg/h;
(59) Commercial kitchens;
(60) Other commercial appliances;
(61) Academic laboratories;
(62) Research laboratories.
(63) Convention according to conditions for dry gas in Latvia: temperature 20 °C, atmospheric pressure 1,01325 bar.
(64) Not regulated.
(65) Not measured;
(66) For forced-draught power burners;
(67) The minimum and maximum set by the appliance manufacturers are to be complied with (these may vary markedly);
(68) Pressure at meter outlet: allowing for permitted tolerance and pressure loss of the meter.
(1) For gas appliances connected to the (natural) gas network (second family):
Article 11 of the Gas Act (the Gas Act relates to the public gas network) reads as follows:
1. |
Gas fed into the gas transportation network or delivered by network managers at exit points shall meet requirements to be laid down by ministerial order. Such requirements may be different for feed-in and exit points and depending on energy content, pressure level and region. |
2. |
The requirements referred to in point 1 above shall in any event cover the safety, efficiency (including in any event minimisation of social costs), reliability and sustainability of the transportation and use of gas. |
Point 2 in particular is taken to mean that, irrespective of the provisions of the ministerial order, safety and efficiency must be maintained in the supply of gas or when changes are made to that supply. In this connection, the technical capabilities of the existing appliances and the existing gas networks are of overriding importance.
Classification of the gas supply of the (natural) gas network:
|
From the perspective of gas appliances, there are three main groups of public gas networks in the Netherlands:
|
|
In addition, the networks are classified in three sub-levels depending on pressure level:
Gas can be supplied on the basis of any pressure level. The gas supply conditions may differ from one pressure level to another. |
|
For other gas appliances:
|
(2) For gas appliances connected to the (natural) gas network (second family):
H gas network: depends on the regional system
Regional system of the H gas network as referred to in the Gas Quality Order |
Wobbe index, Gas Quality Order |
Wobbe index, Gas Quality Order |
Converted Wobbe index |
Converted Wobbe index |
min. |
max. |
min. |
max. |
|
MJ/m3 (25/0) |
MJ/m3 (25/0) |
MJ/m3 (15/15) |
MJ/m3 (15/15) |
|
Other gas systems |
47,0 |
55,7 |
44,59 |
52,84 |
Delfzijl gas system |
48,6 |
55,7 |
46,11 |
52,84 |
Eemshaven gas system |
47,2 |
55,7 |
44,78 |
52,84 |
Zuidoost-Drenthe gas system |
49,0 |
55,7 |
46,49 |
52,84 |
GZI (gaszuiveringsinstallatie) [gas purification plant] gas system |
43,46 |
55,7 |
41,23 |
52,84 |
IJmond gas system |
49,3 |
55,7 |
46,77 |
52,84 |
Province of Limburg |
49,0 |
55,7 |
46,49 |
52,84 |
Provinces of North Holland, South Holland and Groningen |
48,3 |
55,7 |
45,82 |
52,84 |
Refinery gas system |
48,3 |
55,7 |
45,82 |
52,84 |
Westgas/Waalhaven gas system |
47,0 |
57,5 |
44,59 |
54,55 |
Maasmond gas system |
47,0 |
56 |
44,59 |
53,13 |
LNG gas system |
47,0 |
57,2 |
44,59 |
54,27 |
Conversion factor used from 25/0 to 15/15 |
|
|
0,9487 |
0,9487 |
G gas network:
G gas network supply conditions as referred to in the Gas Quality Order |
Wobbe index, Gas Quality Order |
Wobbe index, Gas Quality Order |
Converted Wobbe index |
Converted Wobbe index |
|
min. |
max. |
min. |
max. |
|
MJ/m3 (25/0) |
MJ/m3 (25/0) |
MJ/m3 (15/15) |
MJ/m3 (15/15) |
G conditions |
43,46 |
44,41 |
41,23 |
42,13 |
G+ conditions |
43,46 |
45,30 |
41,23 |
42,98 |
E conditions |
i) |
i) |
i) |
i) |
Conversion factor used from 25/0 to 15/15 |
|
|
0,9487 |
0,9487 |
Note (1) The admissible Wobbe index bandwidth in E supply conditions has not yet been determined. The bandwidth chosen will allow category I2,E appliances to be used safely and efficiently. It will be laid down in the Gas Quality Order in due course. |
(3) For gas appliances connected to the (natural) gas network (second family):
No specific statutory requirements for the sum of the C1 to C5 content. However, there are requirements for the maximum propane equivalent under certain supply conditions in the G gas network.
(Explanation of propane equivalent (PE): unit of content of higher hydrocarbons in gas, calculated as the sum of the proportions in mol % of the higher hydrocarbons in the gas, each higher hydrocarbon being assigned a weighting factor of the number of carbon atoms in the higher hydrocarbon in question minus one, divided by two.)
The requirements are:
G conditions: maximum of 5 mol % propane equivalent (PE)
G+ conditions: maximum of 8,1 mol % propane equivalent (PE)
E conditions: no specific statutory requirements. The admissible content in E supply conditions has not yet been determined. The content chosen will allow category I2,E appliances to be used safely and efficiently. It will be laid down in the Gas Quality Order in due course.
(4) Second gas family, G gas network, G conditions: The following restriction applies to the content of carbon dioxide (CO2) if at least 99 mol % of the gas is made up of methane, carbon dioxide, nitrogen (N2) and oxygen (O2) and more than 6 mol % is made up of CO2.
Maximum CO2 content is the minimum of:
|
* 10,32 – 0,72 * N2 content – 0,87 * O2 content, and |
|
* 10,56 – 0,746 * N2 content – 1,01 * O2 content, |
where the contents are expressed in mol %.
(5) The customer expectations shown below are based on voluntary standards and practices.
(6) In non-domestic applications, nominal pressures of 100 mbar and above are sometimes used.
(69) 3rd Family Gas in not supplied in Poland through gas distribution network;
(70) Values given in MJ/m3 can be converted into kWh/m3 by dividing by 3,6.
(71) Values from the quality of service regulation from Regulator of Energy Services;
(72) Values from the Decree Law number 214E/2015;
(73) No information available;
(74) Some appliances in the catering industry also use pressure 50 mbar for commercial butane and 67 mbar for commercial propane. These are residual cases;
(75) According to ISO 13443:1996 Natural Gas - Standard reference conditions.
(76) When coupling pressure is no greater than 35 mbar;
(77) When coupling pressure exceeds 35 mbar.
(78) Upgraded biogas;
(79) Nominal value.
(80) No specific limits that apply network wide, normally within the range of 36,9 MJ/m3 and 42,3 MJ/m3 but the Wobbe Index provides the overriding limit;
(81) Under a supply emergency these limits can be extended to 46,5–52,85 MJ/m3 to allow for maintenance of supply, this is expected only in exceptional circumstances. The supply conditions are set out in the Gas Safety (Management) Regulations S.I. 1996 No 551 which can be found at www.legislation.gov.uk/uksi/1996/551/made;
(82) No specified limit;
(83) Normally 2,5 mol % but this is variable at some entry points to the transmission system;
(84) Commercial Propane and Butane may contain the substance 1,3 butadiene which is classified as Class II carcinogenic;
(85) As EN437;
(86) LPG for Leisure Accommodation Vehicles to EN 1949;
(87) Bulk Tank or Cylinders (supplying a property) Ref EN 16129 Table 5 and BS6891 Table 7 Note A - These figures relate to the delivery point at the outlet of the regulator or meter (whichever is last);
(88) Cylinder Appliance (directly connected to the cylinder) ΔP2 (2 mbar pressure loss). Note: These figures assume the delivery point is the outlet of the regulator;
(89) Cylinder Appliance (directly connected to the cylinder) Ref EN 16129 Table 5. Note: These figures assume the delivery point is the outlet of the regulator;
(90) Cylinder Appliance (directly connected to the cylinder) ΔP2 (5 mbar pressure loss). Note: These figures assume the delivery point is the outlet of the regulator;
(91) Cylinder Appliance (directly connected to the cylinder) LPG (for Leisure Accommodation Vehicles to EN 1949), Ref EN 16129 Annex D. Note: These figures assume the delivery point is the outlet of the regulator;
(92) Ref BS 6891: 2015 clause 5.3.2 and IGEM/UP/Table 2 for larger pipes;
(93) UKLPG COP 22 Service Pipework;
(94) BS 6891, Property installation pipework; directly connected cylinder appliance systems specifying 2 mbar;
(95) EN 1949; directly connected cylinder appliance systems specifying 5 mbar.