24.8.2006   

EN

Official Journal of the European Union

C 201/31


Commission communication in the framework of the implementation of Council Directive 89/336/EEC of 3 May 1989 on the approximation of the laws of the Member States relating to electromagnetic compatibility

(2006/C 201/02)

(Text with EEA relevance)

(Publication of titles and references of harmonised standards under the Directive)

European standardisation organisation (1)

Reference and title of the standard

(and reference document)

Reference of the superseded standard

Date of cessation of presumption of conformity of the superseded standard

Note 1

Cenelec

EN 50065-1:2001

 

 

Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz — Part 1: General requirements, frequency bands and electromagnetic disturbances

EN 50065-1:1991

+A1:1992

+A2:1995

+A3:1996

Note 2.1

Date expired

(1.4.2003)

Cenelec

EN 50065-2-1:2003

 

 

Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz — Part 2-1: Immunity requirements for mains communications equipment and systems operating in the range of frequencies 95 kHz to 148,5 kHz and intended for use in residential, commercial and light industrial environments

Relevant generic standard(s)

Note 2.3

Date expired

(1.10.2004)

Cenelec

EN 50065-2-2:2003

 

 

Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz — Part 2-2: Immunity requirements for mains communications equipment and systems operating in the range of frequencies 95 kHz to 148,5 kHz and intended for use in industrial environments

Relevant generic standard(s)

Note 2.3

Date expired

(1.10.2004)

Cenelec

EN 50065-2-3:2003

 

 

Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz — Part 2-3: Immunity requirements for mains communications equipment and systems operating in the range of frequencies 3 kHz to 95 kHz and intended for use by electricity suppliers and distributors

Relevant generic standard(s)

Note 2.3

Date expired

(1.8.2004)

Cenelec

EN 50083-2:2001

 

 

Cable networks for television signals, sound signals and interactive services — Part 2: Electromagnetic compatibility for equipment

EN 50083-2:1995

+A1:1997

Note 2.1

Date expired

(1.1.2004)

Amendment A1:2005 to EN 50083-2:2001

Note 3

1.4.2008

Cenelec

EN 50090-2-2:1996

 

 

Home and Building Electronic Systems (HBES) — Part 2-2: System overview — General technical requirements

Relevant generic standard(s)

Note 2.3

Date expired

(1.10.1999)

Cenelec

EN 50091-2:1995

 

 

Uninterruptible power systems (UPS) — Part 2: EMC requirements

Relevant generic standard(s)

Note 2.3

Date expired

(1.3.1999)

Cenelec

EN 50130-4:1995

 

 

Alarm systems — Part 4: Electromagnetic compatibility — Product family standard: Immunity requirements for components of fire, intruder and social alarm systems

Relevant generic standard(s)

Note 2.3

Date expired

(1.1.2001)

Amendment A1:1998 to EN 50130-4:1995

Note 3

Date expired

(1.1.2001)

Amendment A2:2003 to EN 50130-4:1995

Note 3

1.9.2007

Cenelec

EN 50148:1995

 

 

Electronic taximeters

Relevant generic standard(s)

Note 2.3

Date expired

(15.12.1995)

Cenelec

EN 50199:1995

 

 

Electromagnetic compatibility (EMC) — Product standard for arc welding equipment

Relevant generic standard(s)

Note 2.3

Date expired

(1.7.1996)

Cenelec

EN 50240:2004

 

 

Electromagnetic compatibility (EMC) — Product standard for resistance welding equipment

Relevant generic standard(s)

Note 2.3

1.4.2007

Cenelec

EN 50263:1999

 

 

Electromagnetic compatibility (EMC) — Product standard for measuring relays and protection equipment

Relevant generic standard(s)

Note 2.3

Date expired

(1.8.2002)

Cenelec

EN 50270:1999

 

 

Electromagnetic compatibility — Electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen

Relevant generic standard(s)

Note 2.3

Date expired

(1.10.2001)

Cenelec

EN 50293:2000

 

 

Electromagnetic compatibility — Road traffic signal systems — Product standard

Relevant generic standard(s)

Note 2.3

Date expired

(1.4.2003)

Cenelec

EN 50295:1999

 

 

Low-voltage switchgear and control gear — Controller and device interface systems — Actuator Sensor interface (AS-i)

Relevant generic standard(s)

Note 2.3

Date expired

(1.12.1999)

Cenelec

EN 50370-1:2005

 

 

Electromagnetic compatibility (EMC) — Product family standard for machine tools — Part 1: Emission

Relevant generic standard(s)

Note 2.3

1.2.2008

Cenelec

EN 50370-2:2003

 

 

Electromagnetic compatibility (EMC) — Product family standard for machine tools — Part 2: Immunity

Relevant generic standard(s)

Note 2.3

Date expired

(1.11.2005)

Cenelec

EN 50428:2005

 

 

Switches for household and similar fixed electrical installations — Collateral standard — Switches and related accessories for use in home and building electronic systems (HBES)

Relevant generic standard(s)

Note 2.3

1.1.2008

Cenelec

EN 55011:1998

 

 

Industrial, scientific and medical (ISM) radio-frequency equipment — Radio disturbance characteristics — Limits and methods of measurement

(CISPR 11:1997 (Modified))

EN 55011:1991

+A1:1997

+A2:1996

Note 2.1

Date expired

(1.1.2001)

Amendment A1:1999 to EN 55011:1998

(CISPR 11:1997/A1:1999)

Note 3

Date expired

(1.8.2002)

Amendment A2:2002 to EN 55011:1998

(CISPR 11:1997/A2:2002)

Note 3

Date expired

(1.10.2005)

Cenelec

EN 55012:2002

 

 

Vehicles, boats and internal combustion engine driven devices — Radio disturbance characteristics — Limits and methods of measurement for the protection of receivers except those installed in the vehicle/boat/device itself or in adjacent vehicles/boats/devices

(CISPR 12:2001)

Note 8

Relevant generic standard(s)

Note 2.3

Date expired

(1.2.2005)

Amendment A1:2005 to EN 55012:2002

(CISPR 12:2001/A1:2005)

Note 3

1.3.2008

Cenelec

EN 55013:2001

 

 

Sound and television broadcast receivers and associated equipment — Radio disturbance characteristics — Limits and methods of measurement

(CISPR 13:2001 (Modified))

EN 55013:1990

+A12:1994

+A13:1996

+A14:1999

Note 2.1

Date expired

(1.9.2004)

Amendment A1:2003 to EN 55013:2001

(CISPR 13:2001/A1:2003)

Note 3

1.4.2006

Cenelec

EN 55014-1:2000

 

 

Electromagnetic compatibility — Requirements for household appliances, electric tools and similar apparatus — Part 1: Emission

(CISPR 14-1:2000)

EN 55014-1:1993

+A1:1997

+A2:1999

Note 2.1

Date expired

(1.8.2003)

Amendment A1:2001 to EN 55014-1:2000

(CISPR 14-1:2000/A1:2001)

Note 3

Date expired

(1.10.2004)

Amendment A2:2002 to EN 55014-1:2000

(CISPR 14-1:2000/A2:2002)

Note 3

Date expired

(1.10.2005)

Cenelec

EN 55014-2:1997

 

 

Electromagnetic compatibility — Requirements for household appliances, electric tools and similar apparatus — Part 2: Immunity — Product family standard

(CISPR 14-2:1997)

EN 55104:1995

Note 2.1

Date expired

(1.1.2001)

Amendment A1:2001 to EN 55014-2:1997

(CISPR 14-2:1997/A1:2001)

Note 3

Date expired

(1.12.2004)

Cenelec

EN 55015:2000

 

 

Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment

(CISPR 15:2000)

EN 55015:1996

+A1:1997

+A2:1999

Note 2.1

Date expired

(1.8.2003)

Amendment A1:2001 to EN 55015:2000

(CISPR 15:2000/A1:2001)

Note 3

Date expired

(1.12.2004)

Amendment A2:2002 to EN 55015:2000

(CISPR 15:2000/A2:2002)

Note 3

Date expired

(1.10.2005)

Cenelec

EN 55020:1994

 

 

Electromagnetic immunity of broadcast receivers and associated equipment

EN 55020:1988

Note 2.1

Date expired

(31.12.1998)

Amendment A11:1996 to EN 55020:1994

Note 3

Date expired

(1.6.1999)

Amendment A13:1999 to EN 55020:1994

Note 3

Date expired

(1.8.2001)

Amendment A14:1999 to EN 55020:1994

Note 3

Date expired

(1.8.2001)

Amendment A12:1999 to EN 55020:1994

Note 3

Date expired

(1.8.2002)

Cenelec

EN 55020:2002

 

 

Sound and television broadcast receivers and associated equipment — Immunity characteristics — Limits and methods of measurement

(CISPR 20:2002)

EN 55020:1994

and its amendments

Note 2.1

1.12.2006

Amendment A1:2003 to EN 55020:2002

(CISPR 20:2002/A1:2002)

Note 3

1.12.2006

Amendment A2:2005 to EN 55020:2002

(CISPR 20:2002/A2:2004)

Note 3

1.2.2008

Cenelec

EN 55022:1994

 

 

Limits and methods of measurement of radio disturbance characteristics of information technology equipment

(CISPR 22:1993)

EN 55022:1987

Note 2.1

Date expired

(31.12.1998)

Amendment A1:1995 to EN 55022:1994

(CISPR 22:1993/A1:1995)

Note 3

Date expired

(31.12.1998)

Amendment A2:1997 to EN 55022:1994

(CISPR 22:1993/A2:1996 (Modified))

Note 3

Date expired

(31.12.1998)

Cenelec

EN 55022:1998

 

 

Information technology equipment — Radio disturbance characteristics — Limits and methods of measurement

(CISPR 22:1997 (Modified))

EN 55022:1994

and its amendments

Note 2.1

1.8.2007

Amendment A1:2000 to EN 55022:1998

(CISPR 22:1997/A1:2000)

Note 3

1.8.2007

Amendment A2:2003 to EN 55022:1998

(CISPR 22:1997/A2:2002)

Note 3

1.8.2007

Cenelec

EN 55024:1998

 

 

Information technology equipment — Immunity characteristics — Limits and methods of measurement

(CISPR 24:1997 (Modified))

Relevant generic standard(s)

Note 2.3

Date expired

(1.7.2001)

Amendment A1:2001 to EN 55024:1998

(CISPR 24:1997/A1:2001)

Note 3

Date expired

(1.10.2004)

Amendment A2:2003 to EN 55024:1998

(CISPR 24:1997/A2:2002)

Note 3

Date expired

(1.12.2005)

Cenelec

EN 55103-1:1996

 

 

Electromagnetic compatibility — Product family standard for audio, video, audio-visual and entertainment lighting control apparatus for professional use — Part 1: Emission

Relevant generic standard(s)

Note 2.3

Date expired

(1.9.1999)

Cenelec

EN 55103-2:1996

 

 

Electromagnetic compatibility — Product family standard for audio, video, audio-visual and entertainment lighting control apparatus for professional use — Part 2: Immunity

Relevant generic standard(s)

Note 2.3

Date expired

(1.9.1999)

Cenelec

EN 60034-1:1998

 

 

Rotating electrical machines — Part 1: Rating and performance

(IEC 60034-1:1996 (Modified))

Amendment A11:2002 to EN 60034-1:1998

Relevant generic standard(s)

Note 2.3

Date expired

(1.7.2005)

Cenelec

EN 60204-31:1998

 

 

Safety of machinery — Electrical equipment of machines — Part 31: Particular safety and EMC requirements for sewing machines, units and systems

(IEC 60204-31:1996 (Modified))

Relevant generic standard(s)

Note 2.3

Date expired

(1.6.2002)

Cenelec

EN 60439-1:1999

 

 

Low-voltage switchgear and control gear assemblies — Part 1: Type-tested and partially type-tested assemblies

(IEC 60439-1:1999)

EN 60439-1:1994

+A11:1996

Note 2.1

Date expired

(1.8.2002)

Cenelec

EN 60521:1995

 

 

Class 0,5, 1 and 2 alternating-current watt-hour meters

(IEC 60521:1988)

Relevant generic standard(s)

Note 2.3

Date expired

(15.7.1995)

Cenelec

EN 60669-2-1:2000

 

 

Switches for household and similar fixed electrical installations — Part 2-1: Particular requirements — Electronic switches

(IEC 60669-2-1:1996 + A1:1997 (Modified))

EN 60669-2-1:1996

+A11:1997

Note 2.1

Date expired

(1.10.2005)

Amendment A2:2001 to EN 60669-2-1:2000

(IEC 60669-2-1:1996/A2:1999 (Modified))

Note 3

Date expired

(1.10.2005)

Cenelec

EN 60669-2-1:2004

 

 

Switches for household and similar fixed electrical installations — Part 2-1: Particular requirements — Electronic switches

(IEC 60669-2-1:2002 (Modified))

EN 60669-2-1:2000

and its amendment

Note 2.1

1.7.2009

Cenelec

EN 60669-2-2:1997

 

 

Switches for household and similar fixed electrical installations — Part 2: Particular requirements — Section 2: Electromagnetic remote-control switches (RCS)

(IEC 60669-2-2:1996)

Relevant generic standard(s)

Note 2.3

Date expired

(1.6.1999)

Cenelec

EN 60669-2-3:1997

 

 

Switches for household and similar fixed electrical installations — Part 2-3: Particular requirements — Time-delay switches (TDS)

(IEC 60669-2-3:1997)

EN 60669-2-3:1996

Note 2.1

Date expired

(1.6.1999)

Cenelec

EN 60687:1992

 

 

Alternating current static watt-hour meters for active energy (classes 0,2 S and 0,5 S)

(IEC 60687:1992)

Relevant generic standard(s)

Note 2.3

Date expired

(1.6.1993)

Cenelec

EN 60730-1:1995

 

 

Automatic electrical controls for household and similar use — Part 1: General requirements

(IEC 60730-1:1993 (Modified))

Amendment A11:1996 to EN 60730-1:1995

Relevant generic standard(s)

Note 2.3

Date expired

(1.1.1998)

Amendment A17:2000 to EN 60730-1:1995

Note 3

Date expired

(1.10.2002)

Cenelec

EN 60730-1:2000

 

 

Automatic electrical controls for household and similar use — Part 1: General requirements

(IEC 60730-1:1999 (Modified))

Note 7

EN 60730-1:1995

and its amendments

Amendment A1:2004 to EN 60730-1:2000

(IEC 60730-1:1999/A1:2003 (Modified))

Note 3

Cenelec

EN 60730-2-5:1995

 

 

Automatic electrical controls for household and similar use — Part 2: Particular requirements for automatic electrical burner control systems

(IEC 60730-2-5:1993 (Modified))

EN 60730-1:1995

and its amendments

Note 2.3

Date expired

(15.12.2000)

Cenelec

EN 60730-2-5:2002

 

 

Automatic electrical controls for household and similar use — Part 2-5: Particular requirements for automatic electrical burner control systems

(IEC 60730-2-5:2000 (Modified))

Amendment A1:2004 to EN 60730-2-5:2002

(IEC 60730-2-5:2000/A1:2004 (Modified))

EN 60730-2-5:1995

Note 2.1

1.12.2008

Amendment A11:2005 to EN 60730-2-5:2002

Note 3

1.12.2008

Cenelec

EN 60730-2-6:1995

 

 

Automatic electrical controls for household and similar use — Part 2: Particular requirements for automatic electrical pressure sensing controls including mechanical requirements

(IEC 60730-2-6:1991 (Modified))

Amendment A1:1997 to EN 60730-2-6:1995

(IEC 60730-2-6:1991/A1:1994 (Modified))

EN 60730-1:1995

and its amendments

Note 2.3

Date expired

(15.12.2003)

Cenelec

EN 60730-2-7:1991

 

 

Automatic electrical controls for household and similar use — Part 2: Particular requirements for timers and time switches

(IEC 60730-2-7:1990 (Modified))

Amendment A1:1997 to EN 60730-2-7:1991

(IEC 60730-2-7:1990/A1:1994 (Modified))

EN 60730-1:1995

and its amendments

Note 2.3

Date expired

(1.1.2004)

Cenelec

EN 60730-2-8:1995

 

 

Automatic electrical controls for household and similar use — Part 2: Particular requirements for electrically operated water valves, including mechanical requirements

(IEC 60730-2-8:1992 (Modified))

Amendment A1:1997 to EN 60730-2-8:1995

(IEC 60730-2-8:1992/A1:1994 (Modified))

EN 60730-1:1995

and its amendments

Note 2.3

Date expired

(1.1.2004)

Amendment A2:1997 to EN 60730-2-8:1995

(IEC 60730-2-8:1992/A2:1997)

Note 3

Date expired

(1.1.2004)

Cenelec

EN 60730-2-8:2002

 

 

Automatic electrical controls for household and similar use — Part 2-8: Particular requirements for electrically operated water valves, including mechanical requirements

(IEC 60730-2-8:2000 (Modified))

EN 60730-2-8:1995

and its amendments

Note 2.1

1.12.2008

Amendment A1:2003 to EN 60730-2-8:2002

(IEC 60730-2-8:2000/A1:2002 (Modified))

Note 3

1.12.2008

Cenelec

EN 60730-2-9:1995

 

 

Automatic electrical controls for household and similar use — Part 2: Particular requirements for temperature sensing controls

(IEC 60730-2-9:1992 (Modified))

Amendment A1:1996 to EN 60730-2-9:1995

(IEC 60730-2-9:1992/A1:1994 (Modified))

EN 60730-1:1995

and its amendments

Note 2.3

Date expired

(1.1.2004)

Amendment A2:1997 to EN 60730-2-9:1995

(IEC 60730-2-9:1992/A2:1994 (Modified))

Note 3

Date expired

(1.1.2004)

Cenelec

EN 60730-2-9:2002

 

 

Automatic electrical controls for household and similar use — Part 2-9: Particular requirements for temperature sensing controls

(IEC 60730-2-9:2000 (Modified))

EN 60730-2-9:1995

and its amendments

Note 2.1

1.12.2008

Amendment A2:2005 to EN 60730-2-9:2002

(IEC 60730-2-9:2000/A2:2004 (Modified))

Note 3

1.12.2007

Amendment A1:2003 to EN 60730-2-9:2002

(IEC 60730-2-9:2000/A1:2002 (Modified))

Note 3

1.12.2008

Cenelec

EN 60730-2-11:1993

 

 

Automatic electrical controls for household and similar use — Part 2-11: Particular requirements for energy regulators

(IEC 60730-2-11:1993)

Amendment A1:1997 to EN 60730-2-11:1993

(IEC 60730-2-11:1993/A1:1994 (Modified))

EN 60730-1:1995

and its amendments

Note 2.3

Date expired

(1.7.2000)

Amendment A11:2005 to EN 60730-2-11:1993

Note 3

1.3.2009

Cenelec

EN 60730-2-13:1998

 

 

Automatic electrical controls for household and similar use — Part 2-13: Particular requirements for humidity sensing controls

(IEC 60730-2-13:1995 (Modified))

EN 60730-1:1995

and its amendments

Note 2.3

Date expired

(1.8.2001)

Amendment A11:2005 to EN 60730-2-13:1998

Note 3

1.2.2009

Cenelec

EN 60730-2-14:1997

 

 

Automatic electrical controls for household and similar use — Part 2-14: Particular requirements for electric actuators

(IEC 60730-2-14:1995 (Modified))

EN 60730-1:1995

and its amendments

Note 2.3

Date expired

(1.6.2004)

Amendment A1:2001 to EN 60730-2-14:1997

(IEC 60730-2-14:1995/A1:2001)

Note 3

1.7.2008

Cenelec

EN 60730-2-18:1999

 

 

Automatic electrical controls for household and similar use — Part 2-18: Particular requirements for automatic electrical water and air flow sensing controls, including mechanical requirements

(IEC 60730-2-18:1997 (Modified))

EN 60730-1:1995

and its amendments

Note 2.3

Date expired

(1.4.2002)

Cenelec

EN 60870-2-1:1996

 

 

Telecontrol equipment and systems — Part 2: Operating conditions — Section 1: Power supply and electromagnetic compatibility

(IEC 60870-2-1:1995)

Relevant generic standard(s)

Note 2.3

Date expired

(1.9.1996)

Cenelec

EN 60945:2002

 

 

Maritime navigation and radiocommunication equipment and systems — General requirements — Methods of testing and required test results

(IEC 60945:2002)

EN 60945:1997

Note 2.1

Date expired

(1.10.2005)

Cenelec

EN 60947-1:1999

 

 

Low-voltage switchgear and control gear — Part 1: General rules

(IEC 60947-1:1999 (Modified))

Note 6

EN 60947-1:1997

Note 2.1

Date expired

(1.11.2001)

Amendment A2:2001 to EN 60947-1:1999

(IEC 60947-1:1999/A2:2001)

Note 3

Date expired

(1.12.2004)

Cenelec

EN 60947-1:2004

 

 

Low-voltage switchgear and control gear — Part 1: General rules

(IEC 60947-1:2004)

Note 6

EN 60947-1:1999

and its amendment

Note 2.1

1.4.2007

Cenelec

EN 60947-2:1996

 

 

Low-voltage switchgear and control gear — Part 2: Circuit-breakers

(IEC 60947-2:1995)

Relevant generic standard(s)

Note 2.3

Date expired

(1.10.1997)

Amendment A1:1997 to EN 60947-2:1996

(IEC 60947-2:1995/A1:1997)

EN 60947-2:1996/A11:1997

Note 3

Date expired

(1.8.1998)

Amendment A2:2001 to EN 60947-2:1996

(IEC 60947-2:1995/A2:2001)

Note 3

Date expired

(1.7.2004)

Cenelec

EN 60947-2:2003

 

 

Low-voltage switchgear and control gear — Part 2: Circuit-breakers

(IEC 60947-2:2003)

EN 60947-2:1996

and its amendments

Note 2.1

1.6.2006

Cenelec

EN 60947-3:1999

 

 

Low-voltage switchgear and control gear — Part 3: Switches, disconnectors, switch-disconnectors and fuse-combination units

(IEC 60947-3:1999)

EN 60947-3:1992

+A1:1995

Note 2.1

Date expired

(1.1.2002)

Amendment A1:2001 to EN 60947-3:1999

(IEC 60947-3:1999/A1:2001)

Note 3

Date expired

(1.3.2004)

Cenelec

EN 60947-4-1:2001

 

 

Low-voltage switchgear and control gear — Part 4-1: Contactors and motor-starters — Electromechanical contactors and motor-starters

(IEC 60947-4-1:2000)

Amendment A1:2002 to EN 60947-4-1:2001

(IEC 60947-4-1:2000/A1:2002)

EN 60947-4-1:1992

and its amendments

Note 2.1

Date expired

(1.10.2005)

Cenelec

EN 60947-4-2:2000

 

 

Low-voltage switchgear and control gear — Part 4-2: Contactors and motor-starters — AC semiconductor motor controllers and starters

(IEC 60947-4-2:1999)

EN 60947-4-2:1996

+A2:1998

Note 2.1

Date expired

(1.12.2002)

Amendment A1:2002 to EN 60947-4-2:2000

(IEC 60947-4-2:1999/A1:2001)

Note 3

Date expired

(1.3.2005)

Cenelec

EN 60947-4-3:2000

 

 

Low-voltage switchgear and control gear — Part 4-3: Contactors and motor-starters — AC semiconductor controllers and contactors for non-motor loads

(IEC 60947-4-3:1999)

Relevant generic standard(s)

Note 2.3

Date expired

(1.12.2002)

Cenelec

EN 60947-5-1:1997

 

 

Low-voltage switchgear and control gear — Part 5-1: Control circuit devices and switching elements — Electromechanical control circuit devices

(IEC 60947-5-1:1997)

Amendment A12:1999 to EN 60947-5-1:1997

EN 60947-5-1:1991

+A12:1997

Note 2.1

Date expired

(1.10.2002)

Cenelec

EN 60947-5-1:2004

 

 

Low-voltage switchgear and control gear — Part 5-1: Control circuit devices and switching elements — Electromechanical control circuit devices

(IEC 60947-5-1:2003)

EN 60947-5-1:1997

and its amendment

Note 2.1

1.5.2007

Cenelec

EN 60947-5-2:1998

 

 

Low-voltage switchgear and control gear — Part 5-2: Control circuit devices and switching elements — Proximity switches

(IEC 60947-5-2:1997 (Modified))

EN 60947-5-2:1997

Note 2.1

Date expired

(1.10.2001)

Amendment A2:2004 to EN 60947-5-2:1998

(IEC 60947-5-2:1997/A2:2003)

Note 3

1.2.2007

Cenelec

EN 60947-5-3:1999

 

 

Low-voltage switchgear and control gear — Part 5-3: Control circuit devices and switching elements — Requirements for proximity devices with defined behaviour under fault conditions (PDF)

(IEC 60947-5-3:1999)

Relevant generic standard(s)

Note 2.3

Date expired

(1.5.2002)

Amendment A1:2005 to EN 60947-5-3:1999

(IEC 60947-5-3:1999/A1:2005)

Note 3

1.3.2008

Cenelec

EN 60947-5-6:2000

 

 

Low-voltage switchgear and control gear — Part 5-6: Control circuit devices and switching elements — DC interface for proximity sensors and switching amplifiers (NAMUR)

(IEC 60947-5-6:1999)

EN 50227:1997

Note 2.1

Date expired

(1.1.2003)

Cenelec

EN 60947-5-7:2003

 

 

Low-voltage switchgear and control gear — Part 5-7: Control circuit devices and switching elements — Requirements for proximity devices with analogue output

(IEC 60947-5-7:2003)

Relevant generic standard(s)

Note 2.3

1.9.2006

Cenelec

EN 60947-6-1:1991

 

 

Low-voltage switchgear and control gear — Part 6-1: Multiple function equipment — Automatic transfer switching equipment

(IEC 60947-6-1:1989)

Relevant generic standard(s)

Note 2.3

Date expired

(1.10.1997)

Amendment A2:1997 to EN 60947-6-1:1991

(IEC 60947-6-1:1989/A2:1997)

EN 60947-6-1:1991/A11:1997

Note 3

Date expired

(1.7.1998)

Cenelec

EN 60947-6-2:2003

 

 

Low-voltage switchgear and control gear — Part 6-2: Multiple function equipment — Control and protective switching devices (or equipment) (CPS)

(IEC 60947-6-2:2002)

EN 60947-6-2:1993

+A1:1997

Note 2.1

Date expired

(1.9.2005)

Cenelec

EN 60947-8:2003

 

 

Low-voltage switchgear and control gear — Part 8: Control units for built-in thermal protection (PTC) for rotating electrical machines

(IEC 60947-8:2003)

Relevant generic standard(s)

Note 2.3

1.7.2006

Cenelec

EN 60974-10:2003

 

 

Arc welding equipment — Part 10: Electromagnetic compatibility (EMC) requirements

(IEC 60974-10:2002 (Modified))

EN 50199:1995

Note 2.1

1.3.2006

Cenelec

EN 61000-3-2:2000

 

 

Electromagnetic compatibility (EMC) — Part 3-2: Limits — Limits for harmonic current emissions (equipment input current up to and including 16 A per phase)

(IEC 61000-3-2:2000 (Modified))

EN 61000-3-2:1995

+A1:1998

+A2:1998

+A14:2000

Note 2.1

Date expired

(1.1.2004)

Amendment A2:2005 to EN 61000-3-2:2000

(IEC 61000-3-2:2000/A1:2001 + A2:2004)

Note 3

1.1.2008

Cenelec

EN 61000-3-3:1995

 

 

Electromagnetic compatibility (EMC) — Part 3-3: Limits — Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current <= 16 A per phase and not subject to conditional connection

(IEC 61000-3-3:1994)

EN 60555-3:1987

+A1:1991

Note 2.2

Date expired

(1.1.2001)

Amendment A1:2001 to EN 61000-3-3:1995

(IEC 61000-3-3:1994/A1:2001)

Note 3

Date expired

(1.5.2004)

Cenelec

EN 61000-3-11:2000

 

 

Electromagnetic compatibility (EMC) — Part 3-11: Limits — Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems — Equipment with rated current <= 75 A and subject to conditional connection

(IEC 61000-3-11:2000)

Relevant generic standard(s)

Note 2.3

Date expired

(1.11.2003)

Cenelec

EN 61000-3-12:2005

 

 

Electromagnetic compatibility (EMC) — Part 3-12: Limits — Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current > 16 A and <= 75 A per phase

(IEC 61000-3-12:2004)

Relevant generic standard(s)

Note 2.3

1.2.2008

Cenelec

EN 61000-6-1:2001

 

 

Electromagnetic compatibility (EMC) — Part 6-1: Generic standards — Immunity for residential, commercial and light-industrial environments

(IEC 61000-6-1:1997 (Modified))

EN 50082-1:1997

Note 2.1

Date expired

(1.7.2004)

Cenelec

EN 61000-6-2:2001

 

 

Electromagnetic compatibility (EMC) — Part 6-2: Generic standards — Immunity for industrial environments

(IEC 61000-6-2:1999 (Modified))

EN 61000-6-2:1999

Note 2.1

Date expired

(1.7.2004)

Cenelec

EN 61000-6-2:2005

 

 

Electromagnetic compatibility (EMC) — Part 6-2: Generic standards — Immunity for industrial environments

(IEC 61000-6-2:2005)

EN 61000-6-2:2001

Note 2.1

1.6.2008

Cenelec

EN 61000-6-3:2001

 

 

Electromagnetic compatibility (EMC) — Part 6-3: Generic standards — Emission standard for residential, commercial and light-industrial environments

(CISPR/IEC 61000-6-3:1996 (Modified))

EN 50081-1:1992

Note 2.1

Date expired

(1.7.2004)

Amendment A11:2004 to EN 61000-6-3:2001

Note 3

1.7.2007

Cenelec

EN 61000-6-4:2001

 

 

Electromagnetic compatibility (EMC) — Part 6-4: Generic standards — Emission standard for industrial environments

(IEC 61000-6-4:1997 (Modified))

EN 50081-2:1993

Note 2.1

Date expired

(1.7.2004)

Cenelec

EN 61008-1:1994

 

 

Electrical accessories — Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) — Part 1: General rules

(IEC 61008-1:1990 + A1:1992 (Modified))

Amendment A2:1995 to EN 61008-1:1994

(IEC 61008-1:1990/A2:1995)

Relevant generic standard(s)

Note 2.3

Date expired

(1.7.2000)

Amendment A14:1998 to EN 61008-1:1994

Relevant generic standard(s)

Note 2.3

Date expired

(1.1.2001)

Cenelec

EN 61008-1:2004

 

 

Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) — Part 1: General rules

(IEC 61008-1:1996 + A1:2002 (Modified))

EN 61008-1:1994

and its amendments

Note 2.1

1.4.2009

Cenelec

EN 61009-1:1994

 

 

Electrical accessories — Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs) — Part 1: General rules

(IEC 61009-1:1991 (Modified))

Amendment A1:1995 to EN 61009-1:1994

(IEC 61009-1:1991/A1:1995)

Relevant generic standard(s)

Note 2.3

Date expired

(1.7.2000)

Amendment A14:1998 to EN 61009-1:1994

Note 3

Date expired

(1.1.2001)

Cenelec

EN 61009-1:2004

 

 

Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs) — Part 1: General rules

(IEC 61009-1:1996 + A1:2002 (Modified))

EN 61009-1:1994

and its amendments

Note 2.1

1.4.2009

Cenelec

EN 61036:1996

 

 

Alternating current static watt-hour meters for active energy (classes 1 and 2)

(IEC 61036:1996)

EN 61036:1992

Note 2.1

Date expired

(1.6.1997)

Amendment A1:2000 to EN 61036:1996

(IEC 61036:1996/A1:2000)

Note 3

Date expired

(1.6.2003)

Cenelec

EN 61037:1992

 

 

Electricity metering — Tariff and load control — Particular requirements for electronic ripple control receivers

(IEC 61037:1990 (Modified))

None

Amendment A1:1996 to EN 61037:1992

(IEC 61037:1990/A1:1996)

Note 3

Date expired

(1.12.1996)

Amendment A2:1998 to EN 61037:1992

(IEC 61037:1990/A2:1998)

Note 3

Date expired

(1.5.2001)

Cenelec

EN 61038:1992

 

 

Electricity metering — Tariff and load controls — Particular requirements for time switches

(IEC 61038:1990 (Modified))

None

Amendment A1:1996 to EN 61038:1992

(IEC 61038:1990/A1:1996)

Note 3

Date expired

(1.12.1996)

Amendment A2:1998 to EN 61038:1992

(IEC 61038:1990/A2:1998)

Note 3

Date expired

(1.5.2001)

Cenelec

EN 61131-2:1994

 

 

Programmable controllers — Part 2: Equipment requirements and tests

(IEC 61131-2:1992)

Relevant generic standard(s)

Note 2.3

Date expired

(15.3.1995)

Amendment A11:1996 to EN 61131-2:1994

Note 3

Date expired

(1.12.1996)

Amendment A12:2000 to EN 61131-2:1994

Note 3

Date expired

(1.1.2003)

Cenelec

EN 61131-2:2003

 

 

Programmable controllers — Part 2: Equipment requirements and tests

(IEC 61131-2:2003)

EN 61131-2:1994

and its amendments

Note 2.1

1.5.2006

Cenelec

EN 61204-3:2000

 

 

Low voltage power supplies, d.c. output — Part 3: Electromagnetic compatibility (EMC)

(IEC 61204-3:2000)

Relevant generic standard(s)

Note 2.3

Date expired

(1.11.2003)

Cenelec

EN 61268:1996

 

 

Alternating current static var-hour meters for reactive energy (classes 2 and 3)

(IEC 61268:1995)

Relevant generic standard(s)

Note 2.3

Date expired

(1.7.1996)

Cenelec

EN 61326:1997

 

 

Electrical equipment for measurement, control and laboratory use — EMC requirements

(IEC 61326:1997)

Relevant generic standard(s)

Note 2.3

Date expired

(1.7.2001)

Amendment A1:1998 to EN 61326:1997

(IEC 61326:1997/A1:1998)

Note 3

Date expired

(1.7.2001)

Amendment A2:2001 to EN 61326:1997

(IEC 61326:1997/A2:2000)

Note 3

Date expired

(1.4.2004)

Amendment A3:2003 to EN 61326:1997

Note 3

1.10.2006

Cenelec

EN 61543:1995

 

 

Residual current-operated protective devices (RCDs) for household and similar use — Electromagnetic compatibility

(IEC 61543:1995)

Relevant generic standard(s)

Note 2.3

Date expired

(4.7.1998)

Amendment A11:2003 to EN 61543:1995

Note 3

1.3.2007

Amendment A12:2005 to EN 61543:1995

Note 3

1.3.2008

Cenelec

EN 61547:1995

 

 

Equipment for general lighting purposes — EMC immunity requirements

(IEC 61547:1995)

Relevant generic standard(s)

Note 2.3

Date expired

(1.7.1996)

Amendment A1:2000 to EN 61547:1995

(IEC 61547:1995/A1:2000)

Note 3

Date expired

(1.11.2003)

Cenelec

EN 61800-3:1996

 

 

Adjustable speed electrical power drive systems — Part 3: EMC product standard including specific test methods

(IEC 61800-3:1996)

Relevant generic standard(s)

Note 2.3

Date expired

(1.4.1997)

Amendment A11:2000 to EN 61800-3:1996

Note 3

Date expired

(1.1.2002)

Cenelec

EN 61800-3:2004

 

 

Adjustable speed electrical power drive systems — Part 3: EMC requirements and specific test methods

(IEC 61800-3:2004)

EN 61800-3:1996

and its amendment

Note 2.1

1.10.2007

Cenelec

EN 61812-1:1996

 

 

Specified time relays for industrial use — Part 1: Requirements and tests

(IEC 61812-1:1996)

Amendment A11:1999 to EN 61812-1:1996

Relevant generic standard(s)

Note 2.3

Date expired

(1.1.2002)

Cenelec

EN 62052-11:2003

 

 

Electricity metering equipment (AC) — General requirements, tests and test conditions — Part 11: Metering equipment

(IEC 62052-11:2003)

Note 9

Relevant generic standard(s)

Note 2.3

1.3.2006

Cenelec

EN 62052-21:2004

 

 

Electricity metering equipment (AC) — General requirements, tests and test conditions — Part 21: Tariff and load control equipment

(IEC 62052-21:2004)

Note 11

EN 61037:1992

and its amendments + EN 61038:1992

and its amendments

Note 2.1

1.7.2007

Cenelec

EN 62053-11:2003

 

 

Electricity metering equipment (AC) — Particular requirements — Part 11: Electromechanical meters for active energy (classes 0,5, 1 and 2)

(IEC 62053-11:2003)

EN 60521:1995

Note 2.1

1.3.2006

Cenelec

EN 62053-21:2003

 

 

Electricity metering equipment (AC) — Particular requirements — Part 21: Static meters for active energy (classes 1 and 2)

(IEC 62053-21:2003)

EN 61036:1996

and its amendment

Note 2.1

1.3.2006

Cenelec

EN 62053-22:2003

 

 

Electricity metering equipment (AC) — Particular requirements — Part 22: Static meters for active energy (classes 0,2 S and 0,5 S)

(IEC 62053-22:2003)

EN 60687:1992

Note 2.1

1.3.2006

Cenelec

EN 62053-23:2003

 

 

Electricity metering equipment (AC) — Particular requirements — Part 23: Static meters for reactive energy (classes 2 and 3)

(IEC 62053-23:2003)

EN 61268:1996

Note 2.1

1.3.2006

Cenelec

EN 62054-11:2004

 

 

Electricity metering (AC) — Tariff and load control — Part 11: Particular requirements for electronic ripple control receivers

(IEC 62054-11:2004)

EN 61037:1992

and its amendments

Note 2.1

1.7.2007

Cenelec

EN 62054-21:2004

 

 

Electricity metering (AC) — Tariff and load control — Part 21: Particular requirements for time switches

(IEC 62054-21:2004)

EN 61038:1992

and its amendments

Note 2.1

1.7.2007

CEN

EN 617:2001

 

 

Continuous handling equipment and systems — Safety and EMC requirements for the equipment for the storage of bulk materials in silos, bunkers, bins and hoppers

 

CEN

EN 618:2002

 

 

Continuous handling equipment and systems — Safety and EMC requirements for equipment for mechanical handling of bulk materials except fixed belt conveyors

 

CEN

EN 619:2002

 

 

Continuous handling equipment and systems — Safety and EMC requirements for equipment for mechanical handling of unit loads

 

CEN

EN 620:2002

 

 

Continuous handling equipment and systems — Safety and EMC requirements for fixed belt conveyors for bulk materials

 

CEN

EN 12015:1998

 

 

Electromagnetic compatibility — Product family standard for lifts, escalators and passenger conveyors — Emission

 

CEN

EN 12015:2004

 

 

Electromagnetic compatibility — Product family standard for lifts, escalators and moving walks — Emission

EN 12015:1998

30.6.2006

CEN

EN 12016:1998

 

 

Electromagnetic compatibility — Product family standard for lifts, escalators and passenger conveyors — Immunity

 

CEN

EN 12016:2004

 

 

Electromagnetic compatibility — Product family standard for lifts, escalators and moving walks — Immunity

EN 12016:1998

30.6.2006

CEN

EN 12895:2000

 

 

Industrial trucks — Electromagnetic compatibility

 

CEN

EN 13241-1:2003

 

 

Industrial, commercial and garage doors and gates — Product standard — Part 1: Products without fire resistance or smoke control characteristics

 

CEN

EN 13309:2000

 

 

Construction machinery — Electromagnetic compatibility of machines with internal electrical power supply

 

CEN

EN 14010:2003

 

 

Safety of machinery — Equipment for power driven parking of motor vehicles — Safety and EMC requirements for design, manufacturing, erection and commissioning stages

 

CEN

EN ISO 14982:1998

 

 

Agricultural and forestry machines — Electromagnetic compatibility — Test methods and acceptance criteria (ISO 14982:1998)

 

ETSI

EN 300 386 V1.2.1

 

 

Electromagnetic compatibility and radio spectrum matters (ERM); Telecommunication network equipment; Electromagnetic compatibility (EMC) requirements

EN 300 386-2 V1.1.3

31.8.2007

ETSI

EN 300 386 V1.3.1

 

 

Electromagnetic compatibility and radio spectrum matters (ERM); Telecommunication network equipment; Electromagnetic compatibility (EMC) requirements

EN 300 386-2 V.1.1.3

31.8.2007

ETSI

EN 300 386 V1.3.2

 

 

Electromagnetic compatibility and radio spectrum matters (ERM); Telecommunication network equipment; Electromagnetic compatibility (EMC) requirements

EN 300 386-2 V.1.1.3

31.8.2007

ETSI

EN 300 386 V1.3.3

 

 

Electromagnetic compatibility and radio spectrum matters (ERM); Telecommunication network equipment; Electromagnetic compatibility (EMC) requirements

EN 300 386-2 V1.1.3

31.8.2007

ETSI

EN 300 386-2 V1.1.3

 

 

Electromagnetic compatibility and Radio spectrum Matters (ERM); Telecommunication network equipment; Electromagnetic compatibility (EMC) requirements — Part 2: Product family standard

 

 

General remark: when there is a stroke in column 3 (reference of the superseded standard), it means that the referenced standard may not be used without amendment or particular Part for EMC purpose.

Note 1:

Generally the date of cessation of presumption of conformity will be the date of withdrawal (dow), set by the European standardisation organisation, but attention of users of these standards is drawn to the fact that in certain exceptional cases this can be otherwise.

Note 2.1:

The new (or amended) standard has the same scope as the superseded standard. On the date stated, the superseded standard ceases to give presumption of conformity with the essential requirements of the Directive.

Note 2.2:

The new standard has a broader scope than the superseded standard. On the date stated the superseded standard ceases to give presumption of conformity with the essential requirements of the Directive.

Note 2.3:

The new standard has a narrower scope than the superseded standard. On the date stated the (partially) superseded standard ceases to give presumption of conformity with the essential requirements of the Directive for those products that fall within the scope of the new standard. Presumption of conformity with the essential requirements of the Directive for products that still fall within the scope of the (partially) superseded standard, but that do not fall within the scope of the new standard, is unaffected.

Note 3:

In case of amendments, the referenced standard is EN CCCCC:YYYY, its previous amendments, if any, and the new, quoted amendment. The superseded standard (column 3) therefore consists of EN CCCCC:YYYY and its previous amendments, if any, but without the new quoted amendment. On the date stated, the superseded standard ceases to give presumption of conformity with the essential requirements of the Directive.

Example: For EN 61037:1992, the following applies :

Cenelec

EN 61037:1992

 

 

Electricity metering — Tariff and load control — Particular requirements for electronic ripple control receivers

(IEC 61037:1990 (Modified))

[The referenced standard is EN 61037:1992]

None

[There is no superseded standard]

Amendment A1:1996 to EN 61037:1992

(IEC 61037:1990/A1:1996)

[The referenced standard is EN 61037:1997

+A1:1996 to EN 61037:1992

Note 3

[The superseded standard is EN 61037:1992]

Date expired

(1.12.1996)

Amendment A2:1998 to EN 61037:1992

(IEC 61037:1990/A2:1998)

[The referenced standard is EN 61037:1992

+A1:1996 to EN 61037:1992

+A2:1998 to EN 61037:1992]

Note 3

[The superseded standard is EN 61037:1992

+A1:1996 to EN 61037:1992]

Date expired

(1.5.2001)

Note 6:

EN 60947-1:1999 does not give presumption of conformity without another part of the standard. EN 60947-1:2004 does not give presumption of conformity without another part of the standard.

Note 7:

EN 60730-1:2000 does not give presumption of conformity without another part of the standard.

Note 8:

EN 55012 is applicable for giving presumption of conformity with Directive 89/336/EEC for those vehicles, boats and internal combustion engine-driven devices that are not within the scope of Directives 95/54/EC, 97/24/EC, 2000/2/EC or 2004/104/EC.

Note 9:

EN 62052-11:2003 does not give presumption of conformity without a part of the EN 62053 series.

Note 11:

EN 62052-21:2004 does not give presumption of conformity without a part of the EN 62054 series.

This list replaces all the previous lists published in the Official Journal of the European Union.


(1)

CEN: rue de Stassart/De Stassartstraat 36, B-1050 Brussels, tel: (32-2) 550 08 11, fax: (32-2) 550 08 19 (http://www.cenorm.be)

Cenelec: rue de Stassart/De Stassartstraat 35, B-1050 Brussels, tel: (32-2) 519 68 71, fax: (32-2) 519 69 19 (http://www.cenelec.org)

ETSI: 650, route des Lucioles, F-06921 Sophia Antipolis, tel: (33) 492 94 42 12, fax: (33) 493 65 47 16 (http://www.etsi.org)