amending Commission Regulation (EC) No 245/2009 as regards the ecodesign requirements for fluorescent lamps without integrated ballast, for high intensity discharge lamps, and for ballasts and luminaires able to operate such lamps
(Text with EEA relevance)
THE EUROPEAN COMMISSION,
Having regard to the Treaty on the Functioning of the European Union,
Having regard to Directive 2009/125/EC of the European Parliament and of the Council of 21 October 2009 establishing a framework for the setting of ecodesign requirements for energy-related products (1), and in particular Article 15(1) thereof,
After consulting the Ecodesign Consultation Forum,
Whereas:
(1)
After the adoption of Commission Regulation (EC) No 245/2009 of 18 March 2009 implementing Directive 2005/32/EC of the European Parliament and of the Council with regard to ecodesign requirements for fluorescent lamps without integrated ballast, for high intensity discharge lamps, and for ballasts and luminaires able to operate such lamps, and repealing Directive 2000/55/EC of the European Parliament and of the Council (2), it appeared that certain provisions of that Regulation should be amended in order to avoid unintended impacts on the availability and performance of the products covered by that Regulation.
(2)
In addition, it is necessary to improve coherence, as regards the requirements on product information, between on the one hand Regulation (EC) No 245/2009 and on the other hand Commission Regulation (EC) No 244/2009 of 18 March 2009 implementing Directive 2005/32/EC of the European Parliament and of the Council with regard to ecodesign requirements for non-directional household lamps (3).
(3)
The measures provided for in this Regulation are in accordance with the opinion of the Committee established by Article 19(1) of Directive 2009/125/EC,
HAS ADOPTED THIS REGULATION:
Article 1
Amendments to Regulation (EC) No 245/2009
Annexes I, II, III and IV to Regulation (EC) No 245/2009 are amended as set out in the Annex to this Regulation.
Article 2
Entry into force
This Regulation shall enter into force on the first day following its publication in the Official Journal of the European Union.
It shall apply from 13 April 2010.
This Regulation shall be binding in its entirety and directly applicable in all Member States.
Amendments in Annexes I, II, III and IV to Regulation (EC) No 245/2009
Annexes I, II, III and IV to Regulation (EC) No 245/2009 are amended as follows:
1.
Annex I is amended as follows:
(a)
the title is replaced by the following:
‘Exemptions’;
(b)
the introductory sentence in point 1 is replaced by the following:
‘The following lamps shall be exempt from the provisions of Annex III, provided that the technical documentation file drawn up for the purposes of conformity assessment pursuant to Article 8 of Directive 2009/125/EC states which of the technical parameters listed hereunder provide(s) a basis for their exemption:’;
(c)
points 1(c) and 1(d) are replaced by the following:
‘(c)
blended high intensity discharge lamps having:
—
6 % or more of total radiation of the range 250-780 nm in the range of 250-400 nm; and
—
11 % or more of total radiation of the range 250-780 nm in the range of 630-780 nm; and
—
5 % or more of total radiation of the range 250-780 nm in the range of 640-700 nm;
(d)
blended high intensity discharge lamps having:
—
the peak of the radiation between 315-400 nm (UVA) or 280-315 nm (UVB);’;
(d)
point 2 is replaced by the following:
‘2.
The following products shall be exempt from the provisions of Annex III, provided that in all forms of product information it is stated that they are not intended for general lighting use within the meaning of this Regulation, or that they are intended for use in applications listed in points (b) to (e):
(a)
products intended for use in applications other than general lighting and products incorporated into products which do not provide a general lighting function;
(b)
lamps covered by the requirements of Directives 94/9/EC of the European Parliament and of the Council (1) or Directive 1999/92/EC of the European Parliament and of the Council (2);
(c)
emergency lighting luminaires and emergency sign luminaires within the meaning of Directive 2006/95/EC of the European Parliament and of the Council (3).
(d)
ballasts intended for use in luminaires defined in paragraph (c) and designed to operate lamps in emergency conditions;
(e)
luminaires covered by the requirements of Directive 94/9/EC, Directive 1999/92/EC, Directive 2006/42/EC of the European Parliament and of the Council (4), Council Directive 93/42/EEC (5), Council Directive 88/378/EEC (6) and luminaires integrated into equipment covered by these requirements.
The intended purpose shall be stated for each product in the product information, and the technical documentation file drawn up for the purposes of conformity assessment pursuant to Article 8 of Directive 2009/125/EC shall list the technical parameters that make the product design specific for the stated intended purpose.
‘For the purposes of Table 6 in Annex III, the LSF shall be measured in high frequency operating mode with a switching cycle of 11h/1h.’
(c)
The following point (o) is added to point 3:
‘(o)
“Blended lamp” means a lamp containing a mercury vapour lamp and an incandescent lamp filament connected in series in the same bulb.’
3.
Annex III is amended as follows:
(a)
The following paragraph is added before Table 1:
‘Spiral-shaped double capped fluorescent lamps of all diameters equal to or larger than 16 mm (T5) shall comply with the requirements set out in Table 5 for T9 circular lamps.’
(b)
Table 2 is replaced by the following:
‘Table 2
Rated minimum efficacy values for single capped fluorescent lamps working on electromagnetic and electronic ballast
Small single parallel tube, lamp cap G23 (2 pin) or 2G7 (4 pin)
Double parallel tubes, lamp cap G24d (2 pin) or G24q (4 pin)
Triple parallel tubes, lamp cap GX24d (2 pin) or GX24q (4 pin)
Nominal wattage
(W)
Rated luminous efficacy (lm/W), 100 h initial value
Nominal wattage
(W)
Rated luminous efficacy (lm/W), 100 h initial value
Nominal wattage
(W)
Rated luminous efficacy (lm/W), 100 h initial value
5
48
10
60
13
62
7
57
13
69
18
67
9
67
18
67
26
66
11
76
26
66
4 legs in one plane, lamp cap 2G10
(4 pin)
Long single parallel tube, lamp cap 2G11
(4 pin)
Nominal wattage
(W)
Rated luminous efficacy (lm/W), 100 h initial value
Nominal wattage
(W)
Rated luminous efficacy (lm/W), 100 h initial value
18
61
18
67
24
71
24
75
36
78
34
82
36
81 ’
(c)
Table 3 is replaced by the following:
‘Table 3
Rated minimum efficacy values for single capped fluorescent lamps, working only on electronic ballast
Triple parallel tubes, lamp cap GX24q
(4 pin)
Four parallel tubes, lamp cap GX24q
(4 pin)
Long single parallel tube, lamp cap 2G11
(4 pin)
Nominal wattage
(W)
Rated luminous efficacy (lm/W), 100 h initial value
Nominal wattage
(W)
Rated luminous efficacy (lm/W), 100 h initial value
Nominal wattage
(W)
Rated luminous efficacy (lm/W), 100 h initial value
32
75
57
75
40
83
42
74
70
74
55
82
57
75
80
75
70
74 ’
(d)
Table 6 is replaced by the following:
‘Table 6
Deduction percentages for rated minimum efficacy values for fluorescent lamps with high colour temperature and/or high colour rendering and/or second lamp envelope and/or long life
Lamp parameter
Deduction from luminous efficacy at 25 °C
Tc ≥ 5 000 K
–10 %
95 ≥ Ra > 90
–20 %
Ra > 95
–30 %
Second lamp envelope
–10 %
Lamp Survival Factor ≥ 0,50 after 40 000 burning hours
–5 %’
(e)
In Annex III.1.1.B, the sentence
‘The corrections defined for the first stage (Table 6) shall continue to apply’
is replaced by
‘The corrections (Table 6) and the specific requirements for spiral-shaped double capped fluorescent lamps defined for the first stage shall continue to apply.’;
(f)
The title of Table 7 is replaced by the following:
‘
Table 7
Rated minimum efficacy values for high pressure sodium lamps with Ra ≤ 60
’;
(g)
The title of Table 8 is replaced by the following:
‘
Table 8
Rated minimum efficacy values for Metal Halide Lamps with Ra ≤ 80 and for high pressure sodium lamps with Ra > 60
’
(h)
The second paragraph of Annex III.1.1.C is replaced by the following:
‘Fluorescent lamps without integrated ballast shall be able to operate with ballasts of energy efficiency class A2 or more efficient ballasts in accordance with point 2.2 of Annex III. In addition they may also operate with ballasts of less efficient classes than A2.’
(i)
Table 11 is replaced by the following:
‘Table 11
Lamp lumen maintenance factors for single and double capped fluorescent lamps — Stage 2
Lamp lumen maintenance factor
Burning hours
Lamp types
2 000
4 000
8 000
16 000
Double-Capped Fluorescent lamps operating on non-high frequency ballasts
0,95
0,92
0,90
—
T8 Double-Capped Fluorescent lamps on high frequency ballast with warmstart
0,96
0,92
0,91
0,90
Other Double-Capped Fluorescent lamps on high frequency ballast with warmstart
0,95
0,92
0,90
0,90
Circular Single-Capped Fluorescent lamps operating on non-high frequency ballasts, T8 U-shaped double-capped fluorescent lamps and spiral-shaped double capped fluorescent lamps of all diameters equal to or larger than 16 mm (T5)
0,80
0,74
—
—
0,72 at 5 000 burning hours
Circular Single-Capped Fluorescent lamps operating on high frequency ballasts
0,85
0,83
0,80
—
0,75 at 12 000 burning hours
Other Single-Capped Fluorescent lamps operating on non-high frequency ballasts
0,85
0,78
0,75
—
Other Single-Capped Fluorescent lamps on high frequency ballast with warmstart
0,90
0,84
0,81
0,78 ’
(j)
The following introductory phrase and Table 11a is added after Table 11:
‘The following cumulative deductions shall be applied to the values in Table 11:
Table 11a
Deduction percentages for fluorescent lamp lumen maintenance requirements
Lamp parameter
Deduction from lamp lumen maintenance requirement
Lamps with 95 ≥ Ra > 90
At burning hours ≤ 8 000 h: – 5 %
At burning hours > 8 000 h: – 10 %
Lamps with Ra > 95
At burning hours ≤ 4 000 h: – 10 %
At burning hours > 4 000 h: – 15 %
Lamps with a colour temperature ≥ 5 000 K
–10 %’
(k)
Table 12 is replaced by the following:
‘Table 12
Lamp survival factors for single and double capped fluorescent lamps — Stage 2
Lamp survival factor
Burning hours
Lamp types
2 000
4 000
8 000
16 000
Double-Capped Fluorescent lamps operating on non-high frequency ballasts
0,99
0,97
0,90
—
Double-Capped Fluorescent lamps on high frequency ballast with warmstart
0,99
0,97
0,92
0,90
Circular Single-Capped Fluorescent lamps operating on non-high frequency ballasts, T8 U-shaped double-capped fluorescent lamps and spiral-shaped double capped fluorescent lamps of all diameters equal to or larger than 16 mm (T5)
0,98
0,77
—
—
0,50 at 5 000 burning hours
Circular Single-Capped Fluorescent lamps operating on high frequency ballasts
0,99
0,97
0,85
—
0,50 at 12 000 burning hours
Other Single-Capped Fluorescent lamps operating on non-high frequency ballasts
0,98
0,90
0,50
—
Other Single-Capped Fluorescent lamps on high frequency ballast with warmstart
0,99
0,98
0,88
—’
(l)
Table 13 is replaced by the following:
‘Table 13
Lamp lumen maintenance factors and lamp survival factors for high pressure sodium lamps — Stage 2
High pressure sodium lamp category and burning hours for measurement
Lamp lumen maintenance factor
Lamp survival factor
P ≤ 75 W
LLMF and LSF measured at 12 000 burning hours
Ra ≤ 60
> 0,80
> 0,90
Ra > 60
> 0,75
> 0,75
all retrofit lamps designed to operate on high pressure mercury vapour lamp ballast
> 0,75
> 0,80
P > 75 W
LLMF and LSF measured at 16 000 burning hours
Ra ≤ 60
> 0,85
> 0,90
Ra > 60
> 0,70
> 0,65
all retrofit lamps designed to operate on high pressure mercury vapour lamp ballast
> 0,75
> 0,55
The requirements in Table 13 for retrofit lamps designed to operate on high pressure mercury vapour lamp ballast shall be applicable until 6 years after the entry into force of this Regulation.’;
(m)
Annex III.1.3(i) is replaced by the following:
‘(i)
Ambient temperature inside the luminaire at which the lamp was designed to maximise its luminous flux. If this temperature is equal to or lower than 0 °C or equal to or higher than 50 °C, it shall be stated that the lamp is not suitable for indoor use at standard room temperatures.’;
(n)
The following point (j) is added to point 1.3 of Annex III:
‘(j)
For fluorescent lamps without integrated ballast, the energy efficiency index(es) of ballasts as defined in Table 17 with which the lamp can operate.’;
(o)
Table 17 is replaced by the following:
‘Table 17
Energy efficiency index requirements for non-dimmable ballasts for fluorescent lamps
LAMP DATA
BALLAST EFFICIENCY (Plamp/Pinput)
Non-dimmable
Lamp type
Nominal Wattage
ILCOS CODE
Rated/typical wattage
A2 BAT
A2
A3
B1
B2
50 Hz
HF
W
W
W
T8
15
FD-15-E-G13-26/450
15
13,5
87,8 %
84,4 %
75,0 %
67,9 %
62,0 %
T8
18
FD-18-E-G13-26/600
18
16
87,7 %
84,2 %
76,2 %
71,3 %
65,8 %
T8
30
FD-30-E-G13-26/900
30
24
82,1 %
77,4 %
72,7 %
79,2 %
75,0 %
T8
36
FD-36-E-G13-26/1200
36
32
91,4 %
88,9 %
84,2 %
83,4 %
79,5 %
T8
38
FD-38-E-G13-26/1050
38,5
32
87,7 %
84,2 %
80,0 %
84,1 %
80,4 %
T8
58
FD-58-E-G13-26/1500
58
50
93,0 %
90,9 %
84,7 %
86,1 %
82,2 %
T8
70
FD-70-E-G13-26/1800
69,5
60
90,9 %
88,2 %
83,3 %
86,3 %
83,1 %
TC-L
18
FSD-18-E-2G11
18
16
87,7 %
84,2 %
76,2 %
71,3 %
65,8 %
TC-L
24
FSD-24-E-2G11
24
22
90,7 %
88,0 %
81,5 %
76,0 %
71,3 %
TC-L
36
FSD-36-E-2G11
36
32
91,4 %
88,9 %
84,2 %
83,4 %
79,5 %
TCF
18
FSS-18-E-2G10
18
16
87,7 %
84,2 %
76,2 %
71,3 %
65,8 %
TCF
24
FSS-24-E-2G10
24
22
90,7 %
88,0 %
81,5 %
76,0 %
71,3 %
TCF
36
FSS-36-E-2G10
36
32
91,4 %
88,9 %
84,2 %
83,4 %
79,5 %
TC-D / DE
10
FSQ-10-E-G24q=1
FSQ-10-I-G24d=1
10
9,5
89,4 %
86,4 %
73,1 %
67,9 %
59,4 %
TC-D / DE
13
FSQ-13-E-G24q=1
FSQ-13-I-G24d=1
13
12,5
91,7 %
89,3 %
78,1 %
72,6 %
65,0 %
TC-D / DE
18
FSQ-18-E-G24q=2
FSQ-18-I-G24d=2
18
16,5
89,8 %
86,8 %
78,6 %
71,3 %
65,8 %
TC-D / DE
26
FSQ-26-E-G24q=3
FSQ-26-I-G24d=3
26
24
91,4 %
88,9 %
82,8 %
77,2 %
72,6 %
TC-T / TE
13
FSM-13-E-GX24q=1
FSM-13-I-GX24d=1
13
12,5
91,7 %
89,3 %
78,1 %
72,6 %
65,0 %
TC-T / TE
18
FSM-18-E-GX24q=2
FSM-18-I-GX24d=2
18
16,5
89,8 %
86,8 %
78,6 %
71,3 %
65,8 %
TC-T / TC-TE
26
FSM-26-E-GX24q=3
FSM-26-I-GX24d=3
26,5
24
91,4 %
88,9 %
82,8 %
77,5 %
73,0 %
TC-DD / DDE
10
FSS-10-E-GR10q
FSS-10-L/P/H-GR10q
10,5
9,5
86,4 %
82,6 %
70,4 %
68,8 %
60,5 %
TC-DD / DDE
16
FSS-16-E-GR10q
FSS-16-I-GR8
FSS-16-L/P/H-GR10q
16
15
87,0 %
83,3 %
75,0 %
72,4 %
66,1 %
TC-DD / DDE
21
FSS-21-E-GR10q
FSS-21-L/P/H-GR10q
21
19,5
89,7 %
86,7 %
78,0 %
73,9 %
68,8 %
TC-DD / DDE
28
FSS-28-E-GR10q
FSS-28-I-GR8
FSS-28-L/P/H-GR10q
28
24,5
89,1 %
86,0 %
80,3 %
78,2 %
73,9 %
TC-DD / DDE
38
FSS-38-E-GR10q
FSS-38-L/P/H-GR10q
38,5
34,5
92,0 %
89,6 %
85,2 %
84,1 %
80,4 %
TC
5
FSD-5-I-G23
FSD-5-E-2G7
5,4
5
72,7 %
66,7 %
58,8 %
49,3 %
41,4 %
TC
7
FSD-7-I-G23
FSD-7-E-2G7
7,1
6,5
77,6 %
72,2 %
65,0 %
55,7 %
47,8 %
TC
9
FSD-9-I-G23
FSD-9-E-2G7
8,7
8
78,0 %
72,7 %
66,7 %
60,3 %
52,6 %
TC
11
FSD-11-I-G23
FSD-11-E-2G7
11,8
11
83,0 %
78,6 %
73,3 %
66,7 %
59,6 %
T5
4
FD-4-E-G5-16/150
4,5
3,6
64,9 %
58,1 %
50,0 %
45,0 %
37,2 %
T5
6
FD-6-E-G5-16/225
6
5,4
71,3 %
65,1 %
58,1 %
51,8 %
43,8 %
T5
8
FD-8-E-G5-16/300
7,1
7,5
69,9 %
63,6 %
58,6 %
48,9 %
42,7 %
T5
13
FD-13-E-G5-16/525
13
12,8
84,2 %
80,0 %
75,3 %
72,6 %
65,0 %
T9-C
22
FSC-22-E-G10q-29/200
22
19
89,4 %
86,4 %
79,2 %
74,6 %
69,7 %
T9-C
32
FSC-32-E-G10q-29/300
32
30
88,9 %
85,7 %
81,1 %
80,0 %
76,0 %
T9-C
40
FSC-40-E-G10q-29/400
40
32
89,5 %
86,5 %
82,1 %
82,6 %
79,2 %
T2
6
FDH-6-L/P-W4,3x8,5d-7/220
5
72,7 %
66,7 %
58,8 %
T2
8
FDH-8-L/P-W4,3x8,5d-7/320
7,8
76,5 %
70,9 %
65,0 %
T2
11
FDH-11-L/P-W4,3x8,5d-7/420
10,8
81,8 %
77,1 %
72,0 %
T2
13
FDH-13-L/P-W4,3x8,5d-7/520
13,3
84,7 %
80,6 %
76,0 %
T2
21
FDH-21-L/P-W4,3x8,5d-7/
21
88,9 %
85,7 %
79,2 %
T2
23
FDH-23-L/P-W4,3x8,5d-7/
23
89,8 %
86,8 %
80,7 %
T5-E
14
FDH-14-G5-L/P-16/550
13,7
84,7 %
80,6 %
72,1 %
T5-E
21
FDH-21-G5-L/P-16/850
20,7
89,3 %
86,3 %
79,6 %
T5-E
24
FDH-24-G5-L/P-16/550
22,5
89,6 %
86,5 %
80,4 %
T5-E
28
FDH-28-G5-L/P-16/1150
27,8
89,8 %
86,9 %
81,8 %
T5-E
35
FDH-35-G5-L/P-16/1450
34,7
91,5 %
89,0 %
82,6 %
T5-E
39
FDH-39-G5-L/P-16/850
38
91,0 %
88,4 %
82,6 %
T5-E
49
FDH-49-G5-L/P-16/1450
49,3
91,6 %
89,2 %
84,6 %
T5-E
54
FDH-54-G5-L/P-16/1150
53,8
92,0 %
89,7 %
85,4 %
T5-E
80
FDH-80-G5-L/P-16/1150
80
93,0 %
90,9 %
87,0 %
T5-E
95
FDH-95-G5-L/P-16/1150
95
92,7 %
90,5 %
84,1 %
T5-E
120
FDH-120-G5-L/P-16/1450
120
92,5 %
90,2 %
84,5 %
T5-C
22
FSCH-22-L/P-2GX13-16/225
22,3
88,1 %
84,8 %
78,8 %
T5-C
40
FSCH-40-L/P-2GX13-16/300
39,9
91,4 %
88,9 %
83,3 %
T5-C
55
FSCH-55-L/P-2GX13-16/300
55
92,4 %
90,2 %
84,6 %
T5-C
60
FSCH-60-L/P-2GX13-16/375
60
93,0 %
90,9 %
85,7 %
TC-LE
40
FSDH-40-L/P-2G11
40
91,4 %
88,9 %
83,3 %
TC-LE
55
FSDH-55-L/P-2G11
55
92,4 %
90,2 %
84,6 %
TC-LE
80
FSDH-80-L/P-2G11
80
93,0 %
90,9 %
87,0 %
TC-TE
32
FSMH-32-L/P-2GX24q=3
32
91,4 %
88,9 %
82,1 %
TC-TE
42
FSMH-42-L/P-2GX24q=4
43
93,5 %
91,5 %
86,0 %
TC-TE
57
FSM6H-57-L/P-2GX24q=5
FSM8H-57-L/P-2GX24q=5
56
91,4 %
88,9 %
83,6 %
TC-TE
70
FSM6H-70-L/P-2GX24q=6
FSM8H-70-L/P-2GX24q=6
70
93,0 %
90,9 %
85,4 %
TC-TE
60
FSM6H-60-L/P-2G8=1
63
92,3 %
90,0 %
84,0 %
TC-TE
62
FSM8H-62-L/P-2G8=2
62
92,2 %
89,9 %
83,8 %
TC-TE
82
FSM8H-82-L/P-2G8=2
82
92,4 %
90,1 %
83,7 %
TC-TE
85
FSM6H-85-L/P-2G8=1
87
92,8 %
90,6 %
84,5 %
TC-TE
120
FSM6H-120-L/P-2G8=1
FSM8H-120-L/P-2G8=1
122
92,6 %
90,4 %
84,7 %
TC-DD
55
FSSH-55-L/P-GRY10q3
55
92,4 %
90,2 %
84,6 %’
4.
The following paragraph is added after the first paragraph of Annex IV:
‘Member States authorities shall use reliable, accurate and reproducible measurement procedures, which take into account the generally recognised state of the art measurement methods, including methods set out in documents the reference numbers of which have been published for that purpose in the Official Journal of the European Union.’