18.12.2009 |
EN |
Official Journal of the European Union |
L 336/36 |
COMMISSION DECISION
of 15 December 2009
amending Annex D to Council Directive 64/432/EEC as regards diagnostic tests for enzootic bovine leukosis
(notified under document C(2009) 9951)
(Text with EEA relevance)
(2009/976/EU)
THE EUROPEAN COMMISSION,
Having regard to the Treaty on the Functioning of the European Union,
Having regard to Council Directive 64/432/EEC of 26 June 1964 on animal health problems affecting intra-Community trade in bovine animals and swine (1), and in particular the second paragraph of Article 16 thereof,
Whereas:
(1) |
Directive 64/432/EEC applies to intra-Union trade in bovine animals and Chapter II of Annex D thereto sets out the diagnostic tests for enzootic bovine leukosis (EBL) to be used for the control and eradication of that disease and for surveillance and monitoring, as well as for the establishment and maintenance of an officially enzootic-bovine-leukosis–free herd status and certification required for intra-Union trade in bovine animals. |
(2) |
Chapter II of Annex D to Directive 64/432/EEC provides that tests for EBL are to be carried out by either agar gel immune-diffusion test (AGID) with the use of antigen standardised against the official EC standard serum (EI serum), or by the enzyme-linked immunosorbent assay (ELISA) standardised against E4 serum. Both standard sera are supplied by the National Veterinary Institute, Technical University of Denmark. |
(3) |
A new EBL standard serum (E05 serum) has recently been developed by the World Organisation for Animal Health (OIE) Reference Laboratory for Enzootic Bovine Leukosis in Germany (Friedrich-Loeffler-Institute) in cooperation with the OIE Reference Laboratories in the United Kingdom (Veterinary Laboratories Agency) and in Poland (National Veterinary Research Institute) after being tested in a ring trial between those laboratories. The E05 serum has been validated against the EI and E4 sera by different AGID and ELISAs and consequently included as an accredited OIE standard serum in Section B(2) of Chapter 2.4.11 of the OIE Manual of Diagnostic Tests and Vaccines for Terrestrial Animals, Sixth Edition, 2008. This serum is available from the OIE Reference Laboratory for enzootic bovine leukosis in Germany. |
(4) |
In addition, the National Veterinary Institute, Technical University of Denmark has informed the Commission that it is no longer able to fulfil its obligations for the supply of the standard sera currently provided for in Chapter II of Annex D to Directive 64/432/EEC. |
(5) |
The German competent authorities and the Friedrich-Loeffler-Institute have agreed to be a supplier of the E05 serum which shall consequently become the new official European Union (EU) standard serum for EBL. |
(6) |
Directive 64/432/EEC should therefore be amended accordingly. |
(7) |
The measures provided for in this Decision are in accordance with the opinion of the Standing Committee of the Food Chain and Animal Health, |
HAS ADOPTED THIS DECISION:
Article 1
Chapter II of Annex D to Directive 64/432/EEC is replaced by the text in the Annex to this Decision.
Article 2
This Decision is addressed to the Member States.
Done at Brussels, 15 December 2009.
For the Commission
Androulla VASSILIOU
Member of the Commission
ANNEX
Chapter II of Annex D to Directive 64/432/EEC is replaced by the following:
‘CHAPTER II
TESTS FOR ENZOOTIC BOVINE LEUKOSIS
Tests for enzootic bovine leukosis shall be carried out by the agar gel immuno-diffusion test (AGID) under the conditions described in Sections A and B or by the enzyme-linked immunosorbent assay (ELISA) under the conditions described in Section C. The agar gel immuno-diffusion test may only be used for the testing of individual samples. If test results are the subject of a duly-substantiated challenge, an additional check shall be carried out by means of the agar gel immuno-diffusion test.
The AGID and ELISA shall be standardised against the E05 serum, which shall be the official EU standard serum, to be supplied by the:
Friedrich-Loeffler-Institut |
Federal Research Institute for Animal Health |
OIE Reference Laboratory for Enzootic Bovine Leukosis (EBL) |
Südufer 10 |
17493 Greifswald — Insel Riems |
Germany. |
A. Agar gel immuno-diffusion test for enzootic bovine leukosis
1. |
The antigen to be used in the test shall contain bovine leukosis virus glycoprotein. The antigen shall be standardised against the E05 serum. |
2. |
The State institutes, national reference laboratories or official institutes designated in accordance with Article 6a for coordinating standards and methods of diagnosis of the tests for enzootic bovine leukosis shall be made responsible for calibrating the standard working antigen of the laboratory against the E05 serum. |
3. |
The standard antigens used in the laboratory shall be submitted at least once a year to the State institutes, national reference laboratories or official institutes designated in accordance with Article 6a, for testing against the E05 serum. Apart from such standardisation, the antigen in use may be calibrated in accordance with the method described in Section B. |
4. |
The reagents of the tests shall consist of:
|
5. |
A test pattern of seven moisture-free wells shall be cut in the agar to the bottom of the plate; the pattern shall consist of one central well and six wells in a circle around it.
Diameter of central well: 4 mm Diameter of peripheral wells: 6 mm Distance between central and peripheral wells: 3 mm |
6. |
The central well shall be filled with the standard antigen. Peripheral wells 1 and 4 described in B.3 are filled with the known positive serum; wells 2, 3, 5 and 6 with the test sera. The wells shall be filled until the meniscus disappears. |
7. |
This results in the following quantities being obtained:
|
8. |
Incubation shall be for 72 hours at room temperature (20 to 27 °C) in a closed humid chamber. |
9. |
The test may be read at 24 and 48 hours but a final result shall not be obtained before 72 hours:
In inconclusive reactions the test may be repeated and concentrated serum utilised. |
10. |
Any other well configuration or pattern may be utilised provided that the E05 serum diluted 1:10 in negative serum can be detected as positive. |
B. Method for antigen standardisation
1. |
Solutions and materials required:
|
2. |
Procedure:
Dissolve the agarose (1,6 %) in the Tris/HCl buffer by carefully heating to 100 °C. Place in 56 °C water bath for approximately 1 hour. Also, place the bovine leukosis serum dilutions in a 56 °C water bath. Now mix 15 ml of the 56 °C agarose solution with the 15 ml bovine leukosis serum (1:10), quickly shake and pour 15 ml into each of two petri dishes. Repeat this procedure with the bovine leukosis serum diluted 1:5. When the agarose has hardened, holes shall be made in it as follows:
|
3. |
Addition of antigen:
|
4. |
Additional instructions:
Diameter (mm) Dilutions of antigens |
C. Enzyme-linked immunosorbent assay (ELISA) for detecting enzootic bovine leukosis
1. |
The material and reagents to be used shall be as follows:
|
2. |
Standardisation and sensitivity of test
The sensitivity of the ELISA shall be of such a level that the E05 serum is scored positive when diluted 10 times (serum samples) or 250 times (milk samples) more than the dilution obtained of individual samples when these are included in pools. In assays where samples (serum and milk) are tested individually, the E05 serum diluted 1 to 10 (in negative serum) or 1 to 250 (in negative milk) shall be scored positive when tested in the same assay dilution as used for the individual test samples. The institutes referred to in point 2 of Section A shall be responsible for checking the quality of the ELISA, and in particular for determining, for each production batch, the number of samples to be pooled on the basis of the count obtained for the E05 serum. |
3. |
Conditions for use of the ELISA for enzootic bovine leukosis
|