28.12.2006 |
EN |
Official Journal of the European Union |
L 381/24 |
COUNCIL DECISION
of 18 December 2006
concerning conclusion of the Agreement between the Government of the United States of America and the European Community on the coordination of energy-efficiency labelling programmes for office equipment
(2006/1005/EC)
THE COUNCIL OF THE EUROPEAN UNION,
Having regard to the Treaty establishing the European Community, and in particular Article 133, in conjunction with Article 300(2), first subparagraph, first sentence, and Article 300(4) thereof,
Having regard to the proposal from the Commission,
Whereas:
(1) |
The Council Decision authorising the Commission to open negotiations for an Agreement between the Government of the United States of America and the European Community on the coordination of energy-efficiency labelling programmes for office equipment was adopted on 5 May 2006. |
(2) |
The negotiations have been concluded and the Agreement between the Government of the United States of America and the European Community on the coordination of energy-efficiency labelling programmes for office equipment (hereinafter referred to as ‘the Agreement’) was initialled by both Parties on 7 June 2006. |
(3) |
The appropriate internal Community procedures should be established to ensure proper operation of the Agreement. |
(4) |
The market for office equipment is evolving rapidly. It is essential to reassess frequently the potential for maximising energy savings and environmental benefits by stimulating the supply of and demand for energy-efficient products. It is therefore necessary to empower the Commission, assisted by a Community advisory board made up of national representatives and of all interested parties, to reassess and upgrade the Common Specifications for office equipment set out in Annex C to the Agreement regularly and to take certain decisions for implementation of the Agreement, such as the layout of the Energy Star logo and the guidelines for use of the logo contained in Annexes A and B respectively. |
(5) |
Implementation of the Agreement should be reviewed by the Technical Commission established by the Agreement. |
(6) |
Each party to the Agreement should designate a management entity and the procedure for amending the Agreement should be defined. |
(7) |
The Agreement should be approved, |
HAS DECIDED AS FOLLOWS:
Article 1
The Agreement between the Government of the United States of America and the European Community on the coordination of energy-efficiency labelling programmes for office equipment, including its Annexes, is hereby approved on behalf of the Community.
The text of the Agreement and the Annexes thereto are attached to this Decision.
Article 2
The President of the Council is hereby authorised to designate the person(s) empowered to sign the Agreement in order to bind the Community.
Article 3
The President of the Council shall, on behalf of the Community, give the notification in writing provided for in Article XIV(1) of the Agreement.
Article 4
1. The Commission shall represent the Community in the Technical Commission provided for in Article VII of the Agreement, after having heard the views of the members of the European Community Energy Star Board established by Regulation (EC) No 2422/2001 of the European Parliament and of the Council (1). After consulting the European Community Energy Star Board, the Commission shall carry out the tasks referred to in Articles VI(5), VII(1) and (2), and IX(4) of the Agreement.
2. With a view to preparing the position of the Community with regard to amendments to the list of office equipment in Annex C to the Agreement, the Commission shall take into account any opinion given by the European Community Energy Star Board.
3. The position of the Community with regard to decisions to be taken by the management entities shall be determined, with regard to amendments of Annex A (Energy Star name and common logo), Annex B (Guidelines for proper use of the Energy Star name and common logo), and Annex C (Common Specifications) to the Agreement, by the Commission, after consultation of the European Community Energy Star Board.
4. In all other cases, the position of the Community with regard to decisions to be taken by the Parties to the Agreement shall be determined by the Council, acting on a proposal from the Commission in accordance with Article 300 of the Treaty.
Article 5
This Decision shall be published in the Official Journal of the European Union.
Done at Brussels, 18 December 2006.
For the Council
The President
J.-E. ENESTAM
(1) OJ L 332, 15.2.2001, p. 1.
AGREEMENT
between the Government of the United States of America and the European Community on the coordination of energy-efficiency labelling programs for office equipment
The Government of the UNITED STATES OF AMERICA and the EUROPEAN COMMUNITY, hereinafter ‘the Parties’;
DESIRING to maximise energy savings and environmental benefits by stimulating the supply of and demand for energy-efficient products;
TAKING INTO ACCOUNT the Agreement between the Government of the United States of America and the European Community on the Coordination of Energy-Efficient Labelling Programs for Office Equipment, done on 19 December 2000, and its annexes, as amended (hereinafter ‘the 2000 Agreement’);
SATISFIED by the progress made under the 2000 Agreement;
CONVINCED that additional benefits will be achieved by continuing mutual efforts on ENERGY STAR;
HAVE AGREED AS FOLLOWS:
Article I
General Principles
1. A common set of energy-efficiency specifications and a common logo shall be used by the Parties for the purpose of establishing consistent targets for manufacturers, thereby maximising the effect of their individual efforts on the supply of and demand for such product types.
2. The Parties shall use the Common Logo for the purpose of identifying qualified energy-efficient product types listed in Annex C.
3. The Parties shall ensure that common specifications encourage continuing improvement in efficiency, taking into account the most advanced technical practices on the market.
4. The Common Specifications strive to represent not more than 25 percent of models for which data is available at the time the specifications are set while also taking other factors into consideration.
5. The Parties shall endeavour to ensure that consumers have the opportunity to identify efficient products by finding the label in the market.
Article II
Relation to the 2000 Agreement
This Agreement supersedes in its entirety the 2000 Agreement.
Article III
Definitions
For the purposes of this Agreement:
(a) |
‘ENERGY STAR’ means the service mark designated in Annex A and owned by the United States Environmental Protection Agency (‘U.S. EPA’); |
(b) |
‘Common Logo’ means the certification mark designated in Annex A and owned by U.S. EPA; |
(c) |
‘ENERGY STAR Marks’ means the ‘ENERGY STAR’ name and the Common Logo, as well as any versions of these marks that may be developed or modified by the Management Entities or Program Participants, as herein defined, including the sign or marking contained in Annex A of this Agreement; |
(d) |
‘ENERGY STAR Labelling Program’ means a program administered by a Management Entity using common energy-efficiency specifications, marks, and guidelines to be applied to designated product types; |
(e) |
‘Program Participants’ means manufacturers, vendors, or resale agents that sell designated, energy-efficient products that meet the specifications of and who have chosen to participate in, the ENERGY STAR Labelling Program by registering or entering an agreement with the Management Entity of either Party; |
(f) |
‘Common Specifications’ are the energy-efficiency and performance requirements, including testing methods listed in Annex C, used by Management Entities and Program Participants to determine qualification of energy-efficient products for the Common Logo. |
Article IV
Management entities
Each Party hereby designates a management entity responsible for implementation of this Agreement (the ‘Management Entities’). The European Community designates the Commission of the European Communities (‘Commission’) as its Management Entity. The United States of America designates the U.S. EPA as its Management Entity.
Article V
Administration of the ENERGY STAR Labelling Program
1. Each Management Entity shall administer the ENERGY STAR Labelling Program for the energy-efficient product types listed in Annex C, subject to the terms and conditions set forth in this Agreement. Program administration includes registering Program Participants on a voluntary basis, maintaining Program Participant and compliant product lists, and enforcing the terms of the Guidelines for Proper Use of the ENERGY STAR Name and Common Logo set forth in Annex B.
2. The ENERGY STAR Labelling Program shall use the Common Specifications listed in Annex C.
3. To the extent that each Management Entity takes effective measures to educate consumers about the ENERGY STAR Marks, it shall do so in accordance with the Guidelines for Proper Use of the ENERGY STAR Name and Common Logo set forth in Annex B.
4. Each Management Entity shall bear the expenses for all of its activities under this Agreement.
Article VI
Participation in the ENERGY STAR Labelling Program
1. Any manufacturer, vendor or resale agent may enter the ENERGY STAR Labelling Program by registering as a Program Participant with the Management Entity of either Party.
2. Program Participants may use the Common Logo to identify qualified products that have been tested in their own facilities or by an independent test laboratory and that meet the Common Specifications set forth in Annex C, and may self-certify product qualification.
3. The registration of a Program Participant in the ENERGY STAR Labelling Program by the Management Entity of one Party shall be recognised by the Management Entity of the other Party.
4. To facilitate the recognition of Program Participants in the ENERGY STAR Labelling Program in accordance with Paragraph 3 above, the Management Entities shall cooperate in order to maintain common lists of all Program Participants and products that qualify for the Common Logo.
5. Notwithstanding the self-certification procedures specified in Paragraph 2 above, each Management Entity reserves the right to test or otherwise review products that are or have been sold within its territories (in the territories of the European Community Member States in the case of the Commission) to determine whether the products are certified in accordance with the Common Specifications set forth in Annex C. The Management Entities shall communicate and cooperate fully with one another to ensure all products bearing the Common Logo meet the Common Specifications set forth in Annex C.
Article VII
Program coordination between the Parties
1. The Parties shall establish a Technical Commission to review implementation of this Agreement, composed of representatives of their respective Management Entities.
2. In principle, the Technical Commission shall meet annually and shall consult at the request of one of the Management Entities to review the operation and administration of the ENERGY STAR Labelling Program, the Common Specifications set forth in Annex C, product coverage, and the progress in achieving the objectives of this Agreement.
3. Nonparties (including other governments and industry representatives) may attend meetings of the Technical Commission as observers, unless otherwise agreed by both Management Entities.
Article VIII
Registration of the ENERGY STAR Marks
1. The U.S. EPA, as owner of the ENERGY STAR marks, has registered the marks in the European Community as Community Trade Marks. The Commission shall not seek or obtain any registration of the ENERGY STAR marks or any variation of the marks in any country.
2. The U.S. EPA undertakes not to consider as an infringement of these marks the use, by the Commission or by any Program Participant registered by the Commission, of the sign or marking contained in Annex A in accordance with the terms of this Agreement.
Article IX
Enforcement and non-compliance
1. In order to protect the ENERGY STAR marks, each Management Entity shall ensure the proper use of the ENERGY STAR marks within its territory (within the territories of the European Community Member States in the case of the Commission). Each Management Entity shall ensure that the ENERGY STAR marks are used only in the form that appears in Annex A. Each Management Entity shall ensure that the ENERGY STAR marks are used solely in the manner specified in the Guidelines for Proper Use of the ENERGY STAR Name and Common Logo set forth in Annex B.
2. Each Management Entity shall ensure that prompt and appropriate action is taken against Program Participants, whenever it has knowledge that a Program Participant has used an infringing mark or has affixed the ENERGY STAR marks to a product that does not comply with the Specifications set forth in Annex C. Such actions shall include, but not be limited to:
(a) |
informing the Program Participant in writing of its non- compliance with the terms of the ENERGY STAR Labelling Program; |
(b) |
through consultations, developing a plan to reach compliance; and |
(c) |
if compliance cannot be reached, terminating the registration of the Program Participant, as appropriate. |
3. Each Management Entity shall ensure that all reasonable actions are taken to end the unauthorised use of the ENERGY STAR marks or use of an infringing mark by an entity that is not a Program Participant. Such actions shall include, but shall not be limited to:
(a) |
informing the entity using the ENERGY STAR marks of ENERGY STAR Labelling Program requirements and the Guidelines for Proper Use of the ENERGY STAR Name and Common Logo; and |
(b) |
encouraging the entity to become a Program Participant and register qualified products. |
4. Each Management Entity shall immediately notify the Management Entity of the other Party of any infringement of the ENERGY STAR marks of which it has knowledge as well as the action taken to end such infringement.
Article X
Procedures for amending the Agreement and for adding new Annexes
1. Either Management Entity may propose an amendment to this Agreement and may propose new annexes to the Agreement.
2. A proposed amendment shall be made in writing and shall be discussed at the next meeting of the Technical Commission, provided that it has been communicated to the other Management Entity at least sixty days in advance of such meeting.
3. Amendments to this Agreement and decisions to add new annexes shall be made by mutual agreement of the Parties. Amendments to Annexes A, B, and C shall be made according to the provisions of Articles XI and XII.
Article XI
Procedures for amending Annexes A and B
1. A Management Entity seeking to amend Annex A or Annex B shall follow the procedures set forth in paragraphs 1 and 2 of Article X.
2. Amendments to Annexes A and B shall be made by mutual agreement of the Management Entities.
Article XII
Procedures for amending Annex C
1. A Management Entity seeking to amend Annex C to revise existing Specifications, or to add a new product type (‘Proposing Management Entity’) shall follow the procedures set forth in paragraphs 1 and 2 of Article X, and shall include in its proposal:
(a) |
a demonstration that significant energy savings would result from revising the Specifications or adding the new product type; |
(b) |
as appropriate, energy consumption requirements for various power consumption modes; |
(c) |
information on the standardised testing protocols to be used in evaluating the product; |
(d) |
evidence of existing non-proprietary technology that would make possible cost-effective energy savings without negatively affecting product performance; |
(e) |
information on the estimated number of product models that would meet the proposed specification and approximate market share represented; |
(f) |
information on the views of industry groups potentially affected by the proposed amendment; and |
(g) |
a proposed effective date for the new Specifications, taking into consideration product life cycles and production schedules. |
2. Proposed amendments that are accepted by both Management Entities shall enter into force on a date mutually agreed by the Management Entities.
3. If, after receipt of a proposal made in accordance with paragraphs 1 and 2 of Article X, the other Management Entity (‘Objecting Management Entity’) is of the view that the proposal does not meet the requirements specified in Paragraph 1 above or otherwise objects to the proposal it shall promptly (normally by the next Technical Commission Meeting) notify the Proposing Management Entity in writing of its objection and shall include any available information supporting its objection; for example, information demonstrating that the proposal, if adopted, would likely:
(a) |
disproportionately and unfairly confer market power on one company or industry group; |
(b) |
undermine overall industry participation in the ENERGY STAR labelling program; |
(c) |
conflict with its laws and regulations; or |
(d) |
impose burdensome technical requirements. |
4. The Management Entities shall make best efforts to reach agreement on the proposed amendment at the first meeting of the Technical Commission following the proposal. If the Management Entities are unable to reach agreement on the proposed amendment at this Technical Commission meeting, they shall seek to reach agreement in writing prior to the subsequent Technical Commission meeting.
5. If, by the end of the subsequent Technical Commission meeting, the Parties are unable to reach agreement, the Proposing Management Entity shall withdraw its proposal; and with respect to proposals to revise existing Specifications, the corresponding product type shall be removed from Annex C by the date agreed upon in writing by the Management Entities. All Program Participants shall be informed of this change and of the procedures to be followed to implement this change.
6. When preparing new Common Specifications or revising existing Common Specifications, the Management Entities shall ensure effective coordination and consultation among themselves and with their respective stakeholders, particularly with regard to the content of the working documents and timelines.
Article XIII
General provisions
1. Other environmental labelling programs are not covered by this Agreement and may be developed and adopted by either of the Parties.
2. All activities undertaken under this Agreement shall be subject to the applicable laws and regulations of each Party and to the availability of appropriated funds and resources.
3. Nothing in this Agreement shall affect the rights and obligations of any Party deriving from a bilateral, regional or multilateral agreement into which it has entered prior to the entry into force of this Agreement.
4. Without prejudice to any other provisions of this Agreement, either Management Entity may run labelling programs with respect to product types not included in Annex C. Notwithstanding any other provisions of this Agreement, neither Party shall hinder the import, export, sale or distribution of any product because it bears the energy-efficiency marks of the Management Entity of the other Party.
Article XIV
Entry into force and duration
1. This Agreement shall enter into force on the date upon which each Party has notified the other in writing that its respective internal procedures necessary for its entry into force have been completed.
2. This Agreement shall remain in force for a period of five years. At least one year prior to the end of this period, the Parties shall meet to discuss renewal of this Agreement.
Article XV
Termination
1. Either Party may terminate this Agreement at any time by providing three months written notice to the other Party.
2. In the event of termination or non-renewal of this Agreement, the Management Entities shall inform all Program Participants which they have registered of the termination of the joint program. Moreover, Management Entities shall inform the Program Participants which they have registered that each Management Entity may continue the labelling activities under two separate individual programs. In this case, the European Community labelling program will not use the ENERGY STAR marks. The Commission shall ensure that itself, the Member States of the European Community and any Program Participants which it has registered cease using the ENERGY STAR marks by the date agreed upon in writing by the Management Entities. The obligations contained in this Article XV (2) shall survive the termination of this Agreement.
Article XVI
Authentic languages
Done in duplicate at Washington D.C. on the twentieth day of December in the year two thousand and six in the Czech, Danish, Dutch, English, Estonian, Finnish, French, German, Greek, Hungarian, Italian, Latvian, Lithuanian, Maltese, Polish, Portuguese, Slovakian, Slovenian, Spanish and Swedish, languages, each of these versions being equally authentic. In case of difficulties concerning interpretation, English shall prevail.
Por la Comunidad Europea
Za Evropské společenství
For Det Europæiske Fællesskab
Für die Europäische Gemeinschaft
Euroopa Ühenduse nimel
Για την Ευρωπαϊκή Κοινότητα
For the European Community
Pour la Communauté européenne
Per la Comunità europea
Eiropas Kopienas vārdā
Europos bendrijos vardu
az Európai Közösség részéről
Għall-Komunità Ewropea
Voor de Europese Gemeenschap
W imieniu Wspólnoty Europejskiej
Pela Comunidade Europeia
Za Európske spoločenstvo
Za Evropsko skupnost
Euroopan yhteisön puolesta
För Europeiska gemenskapens vägnar
Por el Gobierno de los Estados Unidos de América
Za vládu Spojených států amerických
For regeringen for Amerikas Forenede Stater
Für die Regierung der Vereinigten Staaten von Amerika
Ameerika Ühendriikide valitsuse nimel
Για την Κυβερνηση των Ηνωμενων Πολιτειων τησ Αμερικησ
For the Government of the United States of America
Pour le gouvernement des États-Unis d'Amérique
Per il governo degli Stati Uniti d'America
Amerikas Savienoto Valstu valdības vārdā
Jungtinių Amerikos Valstijų vyriausybės vardu
az Amerikai Egyesült Államok kormánya részéről
Għall-Gvern ta' l-Istati Uniti ta' l-Amerika
Voor de regering van Verenigde Staten van Amerika
W imieniu rządu Stanów Zjednoczonych Ameryki
Pelo governo Estados Unidos da América
Za vládu Spojené štáty americké
Za vlado Združene države Amerike
Amerikan yhdysvaltojen hallituksen puolesta
För Amerikas förenta staters regering
ANNEX A
ENERGY STAR NAME AND COMMON LOGO
Name: ENERGY STAR
Common logo:
ANNEX B
Guidelines for proper use of the Energy Star name and common logo
The ENERGY STAR name and Common logo are marks of the U.S. EPA. As such, the name and Common logo may only be used in accordance with the following guidelines and the Partnership Agreement or the European Commission Registration Form signed by Program Participants in the ENERGY STAR labelling program. Please distribute these guidelines to those who will be responsible for preparing ENERGY STAR materials on your behalf.
U.S. EPA, and the European Commission, in the European Community Member States Territory oversee proper use of the ENERGY STAR name and Common logo. This includes monitoring the use of the marks in the marketplace, and directly contacting those organisations that are using them improperly or without authorisation. Consequences of misusing the marks may include the termination of the Program Participant's participation in the ENERGY STAR labelling program, and, for products imported into the U.S. improperly using the marks, the possible seizure by the U.S. Customs Services of those goods.
General Guidelines
The ENERGY STAR Program is a partnership between businesses and organisations on one side and the US Federal government or the European Community on the other side. As part of this partnership, businesses and organisations can use the ENERGY STAR name and Common logo, as part of their energy efficiency and environmental activities.
Organisations must enter into an agreement with a management entity – the Environmental Protection Agency for the US or the European Commission for the EU– to use the marks as provided in this document. Alterations to these marks are not allowed as the alterations would confuse businesses and consumers about the source of the ENERGY STAR program and reduce its value for all.
Organisations using these marks must abide by the following general guidelines:
1. |
The ENERGY STAR name and Common Logo may never be used in any manner that would imply endorsement of a company, its products, or its services. Neither the Common Logo nor the ENERGY STAR name may be used in any other company name or logo, product name, service name, domain name, or Web site title, nor may the Common Logo, the ENERGY STAR name, or any similar mark be applied for as a trademark, or as part of a trademark by any entity other than the U.S. EPA. |
2. |
The ENERGY STAR name and Common Logo may never be used in a manner that would disparage ENERGY STAR, EPA, the Department of Energy, the European Community, the European Commission, or any other government body. |
3. |
The Common Logo may never be associated with products that do not qualify as ENERGY STAR. |
4. |
Partners and other authorised organisations are responsible for their own use of the ENERGY STAR name and Common Logo, as well as use by their representatives, such as ad agencies and implementation contractors. |
Using the ENERGY STAR Name
— |
The ENERGY STAR name should always appear in capital letters; |
— |
The registration symbol ® must be used with the first time the words ‘ENERGY STAR’ appear in material for the U.S. market; and |
— |
The ® symbol should always be in superscript; |
— |
There shall be no space between the words ‘ENERGY STAR’ and the ® symbol; |
— |
The ® symbol shall be repeated in a document for each chapter title or Web page. |
Using the Common Logo
The Common Logo is a mark to be used as a label only on those products that meet or exceed ENERGY STAR performance guidelines.
Uses of the Common Logo include:
— |
On a qualifying and registered product; |
— |
In product literature for a qualifying product; |
— |
On the Web to identify a qualifying product; |
— |
In advertising where it is used near to or on a qualifying product; |
— |
On Point of Purchase materials; |
— |
On qualifying product packaging. |
Appearance of the Common Logo
US EPA created this mark to maximise the visual impression of the mark and for contrast and legibility. The mark includes the ENERGY STAR symbol in a block with the ENERGY STAR name in a block directly below to reinforce the legibility of the symbol. The two blocks are separated by a white rule equal in thickness to the arc within the symbol. The mark also has a white key line around it that is also equal in thickness to the arc within the symbol.
Clear Space
US EPA and the EU Commission require that a clear space of .333 (1/3) the height of the graphic box within the mark surround the mark at all times. No other graphic elements, such as text and images can appear in this area. US EPA and the EU Commission require this clear space since the Common logo frequently appears on materials using complex imagery such as other marks, graphic devices, and text.
Minimum Size
The mark may be resized, but the proportions must be maintained. For legibility, we recommend that the mark not be reproduced smaller in width than .375 inch (3/8″; 9.5 mm) for print. Lettering legibility inside the mark must be maintained on the Web.
Preferred Colour
The preferred colour for the mark is 100 % Cyan. Alternate versions in black or reversed out to white are allowed. The Web colour equivalent of 100 % Cyan is hex colour #0099FF. If multicolour printing is available for advertising, product literature, or point of purchase materials the mark should be printed in 100 % Cyan. If this colour is not available, then black can be substituted.
Incorrect Uses of the Mark
Please:
— |
Do not use the mark on non-qualifying products. |
— |
Do not alter the mark by using the ENERGY STAR symbol block without the block containing the name ‘ENERGY STAR’. |
When reproducing the mark please:
— |
Do not make the mark an outline. |
— |
Do not use a white mark on a white background. |
— |
Do not change the colours of the mark. |
— |
Do not distort the mark in any way. |
— |
Do not alter the lock up of the mark. |
— |
Do not place the mark on a busy image. |
— |
Do not rotate the mark. |
— |
Do not separate any of the mark's elements. |
— |
Do not substitute any part of the mark. |
— |
Do not use any other typeface to replace part of the mark. |
— |
Do not violate the clear space of the mark. |
— |
Do not skew the mark. |
— |
Do not change the size of the mark lock up. |
— |
Do not replace the approved wording. |
— |
Do not use the Common logo in an unapproved colour. |
— |
Do not let text run into the mark. |
— |
Do not use the symbol block alone. The ENERGY STAR name must appear as well. |
— |
Do not delete the symbol block from the mark. |
Writing and Talking About ENERGY STAR
To maintain and build the value of ENERGY STAR, U.S. EPA and the EU Commission recommend terminology to use when writing and talking about elements of the program.
CORRECT |
INCORRECT |
ENERGY STAR qualified computer |
ENERGY STAR compliant computer ENERGY STAR certified computer ENERGY STAR rated computer |
Computer that has earned the ENERGY STAR |
|
Products that have earned the ENERGY STAR |
ENERGY STAR product ENERGY STAR products (referring to a suite of products) ENERGY STAR equipment Endorsed by US EPA Meeting ENERGY STAR standards |
PARTNERS/PROGRAM PARTICPANTS |
|
An ENERGY STAR Partner |
An ENERGY STAR company |
Company X, an ENERGY STAR Partner |
Company X, a company endorsed by US EPA |
A company participating in ENERGY STAR |
A US EPA approved seller of ENERGY STAR equipment |
A company promoting ENERGY STAR |
Endorsed by US EPA |
ENERGY STAR qualified monitors |
ENERGY STAR Monitor Program |
GOVERNMENT SOURCE OF AUTHORITY |
|
Products that earn the ENERGY STAR prevent greenhouse gas emissions by meeting strict energy efficiency guidelines set by the US EPA and the EU Commission |
|
ENERGY STAR and the ENERGY STAR mark are registered US marks |
|
ENERGY STAR is a registered mark owned by the US government |
|
PERFORMANCE GUIDELINES |
|
ENERGY STAR guidelines |
ENERGY STAR Standards |
ENERGY STAR specifications |
US EPA-approved |
ENERGY STAR performance levels |
US EPA-endorsed |
Voluntary programs |
Received an endorsement by US EPA |
Questions Regarding the Use of the ENERGY STAR Name and Common Logo
ENERGY STAR Hotline
In the U.S. call toll-free:1-888-STAR-YES (1-888-782–7937)
Outside the U.S. Call: 202-775–6650
Fax: 202-775–6680
www.energystar.gov
EUROPEAN COMMISSION
Directorate-General Energy and Transport
Phone: +32 2 2985792
Fax: +32 2 2966016
www.eu-energystar.org
ANNEX C
COMMON SPECIFICATIONS
I. COMPUTER SPECIFICATIONS
The following Computer Specifications shall be applicable through 19 July 2007. See Section VIII for the Computer Specifications that shall be applicable as of 20 July 2007.
A. Definitions
1. |
Computer: A desktop, tower or mini-tower, or portable unit, including high-end desktop computers, personal computers, workstations, network computer desktops, X terminal controllers, and computer-based point-of-sale retail terminals. To qualify, the unit must be capable of being powered from a wall outlet, but this does not preclude units that are capable of being powered from a wall outlet and also from a battery. This definition is intended primarily to cover computers sold for use in businesses or homes. This definition of a computer does not include computers sold or otherwise marketed as ‘File Server’ or ‘Server’. |
2. |
Monitor: A cathode-ray tube (CRT), flat panel display (e.g. a liquid crystal display) or other display device and its associated electronics. A monitor may be sold separately or integrated into the computer chassis. This definition is intended primarily to cover standard monitors designed for use with computers. For purposes of this specification, however, the following may also be considered a monitor: mainframe terminals, and physically separate display units. |
3. |
Integrated computer system: Systems in which the computer and visual display monitor are combined into a single unit. Such systems must meet all of the following criteria: it is not possible to measure the power consumption of the two components separately; and the system is connected to the wall outlet through a single power cable. |
4. |
Inactivity: A period of time during which a computer does not encounter any user input (e.g. keyboard input or mouse movement). |
5. |
Low-power or ‘sleep’ mode: The reduced power state that the computer enters after a period of inactivity. |
6. |
Wake events: A user, programmed, or external event or stimulus that causes the computer to transition from its low-power/.sleep. mode to its active mode of operation. Examples of wake events include, but are not limited to, movement of the mouse, keyboard activity or a button press on the chassis and, in the case of external events, stimulus conveyed via a telephone, remote control, network, cable modem, satellite, etc. |
B. Product qualification for ENERGY STAR
1. |
Technical specifications
|
2. |
Shipment Settings: In order to ensure that the maximum number of users take advantage of the low-power/‘sleep’ state, Program Participant shall ship its computers and/or integrated computer systems with the power management feature enabled. The default time for all products shall be pre-set for less than 30 minutes. (EPA recommends that the pre-set time be set between 15 and 30 minutes). The user shall have the ability to change the time settings or disable the sleep/low-power mode. |
3. |
Operating Systems: The proper activation of a computer's low-power/‘sleep’ mode is typically contingent upon the installation and use of a particular version of an operating system. If a computer is shipped from the Program Participant with one or more operating systems, the computer shall be capable of entering and fully recovering from the low-power/‘sleep’ sleep mode while running in at least one of those operating systems. If the computer is not shipped with operating system software, the Program Participant shall clearly specify which mechanism will render the computer ENERGY STAR qualified. In addition, if any special software, hardware drivers, or utilities are necessary for the proper activation and recovery of the sleep mode, they must be installed in the computer. The Program Participant shall include this information in product literature (e.g. user's manual or data sheets) and/or on its Internet website. Brochures and advertisements shall be worded to avoid misleading statements. |
4. |
Monitor Control: The computer shall include one or more mechanisms through which it can activate the low-power modes of an ENERGY STAR qualified monitor. Program Participant shall clearly specify in product literature the manner in which its computer can control ENERGY STAR qualified monitors, and any special circumstances that must exist in order for monitor power management to be accomplished. Program Participant shall set the computer's default to activate the monitor's first low-power or sleep mode within 30 minutes of user inactivity. Program Participant shall also set the default time for the next level of power management such that the monitor enters the second low-power or ‘deep sleep’ mode within 60 minutes of inactivity. The combined total of the default times for both low-power modes shall not exceed 60 minutes. Program Participant can choose to set the computer to activate the monitor to enter the second low-power or ‘deep sleep’ mode directly within 30 minutes of inactivity. The user shall have the ability to change the time settings or disable the low-power modes for the monitor control. This monitor control requirement does not apply to integrated computer systems. However, integrated computer systems that are marketed and sold as part of a docking system shall have the capability to automatically control the power of an externally connected monitor. |
C. Test Guidelines for ENERGY STAR Qualified Computers
1. |
Test Conditions: Outlined below are the ambient test conditions which should be established when performing the power measurement. These are necessary in order to ensure that outside factors do not affect the test results, and that test results can be reproduced later. Line Impedance: < 0.25 ohm Total Harmonic Distortion: < 5 % Voltage: Input AC Voltage (2): 115 VAC RMS ±5 V RMS Input AC Frequency (3): 60 Hz ±3 Hz Ambient Temperature: 25 deg. C ±3 deg. C |
2. |
Testing Equipment: The goal is to accurately measure the TRUE power consumption (4) of the device or monitor. This necessitates the use of a True RMS Watt-Meter. There are many watt-meters to choose from, but manufacturers will need to exercise care in selecting an appropriate model. The following factors should be considered when purchasing a meter and setting up the actual test. Crest Factor: A previous version of the ENERGY STAR testing procedure included a requirement that manufacturers utilise a watt-meter with a crest factor greater than 8. As many Program Participants pointed out, this is not a useful or relevant requirement. The following paragraphs are meant to discuss the issues relating to crest factor and to clarify the intent of the initial incorrect statement. Unfortunately, in order to remedy the error, the ENERGY STAR program cannot provide a specific equipment requirement. Testing is as much art as it is science, and manufacturers and testers will have to exercise judgement, and draw on people well versed in testing issues, to select an appropriate meter. To begin, it is important to understanding that devices which contain switching power supplies draw current in a waveform different from typical sinusoidal current (5). Figure 1 shows the typical current waveform for a typical switched electronic device. While virtually any watt-meter can measure a standard current waveform, it is more difficult to select a watt meter when irregular current waveforms are involved. It is critical that the watt-meter selected be capable of reading the current drawn by the device without causing internal peak distortion (i.e., clipping off the top of the current wave). This requires a review of the meter's crest factor (6), and of the current ranges available on the meter. Better meters will have higher crest factors, and more choices of current ranges. When preparing the test, the first step should be to determine the peak current (amps) associated with the device being measured. This can be accomplished using an oscilloscope. Then a current range must be selected that will enable the meter to register the peak current. Specifically, the full scale value of the current range selected multiplied by the crest factor of the meter (for current) must be greater than the peak current reading from the oscilloscope. For example, if a watt meter has a crest factor of 4, and the current range is set on 3 amps, the meter can register current spikes of up to 12 amps. If measured peak current is only 6 amps, the meter would be satisfactory. The other concern to be aware of is that if the current range is set too high in order to register peak current, it may lose accuracy in measuring the non-peak current. Therefore, some delicate balancing is necessary. Again, with more current range choices and higher crest factors you will get better results. Frequency Response: Another issue to consider when selecting a watt-meter is the frequency response rating of the meter. Electronic equipment that contains switching power supplies causes harmonics (odd harmonics typically up to the 21st). These harmonics must be accounted for in power measurement, or the Wattage consumption will be inaccurate. Accordingly, ENERGY STAR recommends that manufacturers purchase watt-meters that have a frequency response of at least 3 kHz. This will account for harmonics up to the 50th, and is recommended by IEC 555. Resolution: Manufacturers will probably want a meter than can provide resolution of 0.1 W. Accuracy: Another feature to consider is the resulting accuracy you will be able to achieve. Catalogues and specification sheets for watt-meters typically provide information on the accuracy of power readings that can be achieved at different range settings. If you are measuring a product that is very close to the maximum energy consumption for the mode being tested, you will need to set up a test that will provide greater accuracy. Calibration: Watt meters should be calibrated every year to maintain their accuracy. |
3. |
Test Method: Manufacturers should measure the Average power consumption of the devices when in the off or low-power modes. This should be done by measuring the Energy consumption over a 1-hour period. The resulting energy consumption can be divided by 1 hour to calculate average Watts. Power Measurement for Energy Saving Modes: This test should be conducted for each of the energy saving modes (e.g., low-power, off, standby, sleep) applicable to a particular device for ENERGY STAR qualification. Prior to the start of this test, the machine should have been plugged in to a live power line but turned off and stabilised at room ambient conditions for at least 12 hours. An appropriate watt-hour meter should be in line with the machine, ready to give an accurate indication of machine energy consumption without disruption of the power source. This measurement may be done sequentially with the off-mode power measurement; the two tests together should take no more than 14 hours to perform, including the time required for the machine to be plugged in and turned off. Turn on the device, and let it go through its warm-up cycle. After the default time to the energy saving mode has passed, read and record the watt-hour meter indication and the time (or start the stopwatch or timer). After 1 hour, read and record the watt-hour indication again. The difference between the two readings of the watt-hour meter is the low-power mode energy use; divide by 1 hour to obtain the average power rating. |
II. COMPUTER MONITOR SPECIFICATIONS
A. Definitions
1. |
Computer Monitor (also referred to as ‘Monitor’): A commercially-available, electronic product with a display screen and its associated electronics encased in a single housing that is capable of displaying output information from a computer via one or more inputs, such as VGA, DVI, and/or IEEE 1394. The monitor usually relies upon a cathode-ray tube (CRT), liquid crystal display (LCD), or other display device. This definition is intended primarily to cover standard monitors designed for use with computers. To qualify, the computer monitor must have a viewable diagonal screen size greater than 12 inches and must be capable of being powered by a separate AC wall outlet or a battery unit that is sold with an AC adapter. Computer monitors with a tuner/receiver may qualify as Energy Star under this specification as long as they are marketed and sold to consumers as computer monitors (i.e., focusing on computer monitor as the primary function) or as dual function computer monitors and televisions. However, products with a tuner/receiver and computer capability that are marketed and sold as televisions are not included in this specification. |
2. |
On Mode/Active Power: The product is connected to a power source and produces an image. The power requirement in this mode is typically greater than the power requirement in Sleep and Off Modes. |
3. |
Sleep Mode/Low Power: The reduced power state that the computer monitor enters after receiving instructions from a computer or via other functions. A blank screen and reduction in power consumption characterise this mode. The computer monitor returns to On Mode with full operational capability upon sensing a request from a user/computer (e.g., user moves the mouse or presses a key on the keyboard). |
4. |
Off Mode/Standby Power: The lowest power consumption mode which cannot be switched off (influenced) by the user and that may persist for an indefinite time when a computer monitor is connected to the main electricity supply and used in accordance with the manufacturer's instructions. For purposes of this specification, Off Mode is defined as the power state when the product is connected to a power source, produces no images, and is waiting to be switched to On Mode by a direct signal from a user/computer (e.g., user pushes power switch) (7). |
5. |
Hard Off Mode: A condition where the product is still plugged into the mains, but has been disconnected from an external power source. This mode is usually engaged by the consumer via a ‘hard off switch.’ While in this mode, a product will not draw any electricity and will usually measure 0 watts when metered. |
6. |
Disconnect: The product has been unplugged from the mains and therefore is disconnected from all external power sources. |
B. Qualifying Products
In order to qualify as ENERGY STAR, a computer monitor model must meet the definition in Section A, and the specification requirements provided in Section II.C, below. As explained in Section II.A.1, this specification does not cover products with computer capability that are marketed and sold as televisions.
C. Energy-Efficiency Specifications for Qualifying Products
Only those products listed in Section II.B that meet the following criteria may qualify as ENERGY STAR.
Widescreen Models: Widescreen (e.g., 16:9, 15:9, etc.) models are eligible to earn the ENERGY STAR, provided that they meet the energy-efficiency requirements in these specifications. There are no separate specifications for widescreen models and as such, they must comply with Sections II.C.1 and II.C.2, below.
1. |
On Mode/Active Power: To qualify as ENERGY STAR, computer monitor models must not exceed the following maximum active power consumption equation: If X < 1 megapixel, then Y = 23; if X > 1 megapixel, then Y = 28X. Y is expressed in watts and rounded up to the nearest whole number and X is the number of megapixels in decimal form (e.g., 1 920 000 pixels = 1.92 megapixels). For example, the maximum power consumption for a computer monitor with 1 024 × 768 resolution (or .78 megapixels) would be Y = 23 watts and for a computer monitor with 1 600 × 1 200 resolution would be 28(1.92) = 53.76 or 54 watts when rounded up To qualify a computer monitor as ENERGY STAR, it must be tested according to the protocol outlined in Section II.D, Test Methodology. |
2. |
Sleep and Off Modes
|
D. Test Methodology
Product Testing Set-up, Methodology, and Documentation: The testing and measurement methods below reference published specifications from the Video Electronics Standards Association (VESA) Display Metrology Committee and the International Electrotechnical Commission (IEC), and supplement those guidelines where necessary with methods developed in cooperation with the computer monitor industry.
Manufacturers are required to perform tests and self-certify those product models that meet the ENERGY STAR guidelines. Families of computer monitor models that are built on the same chassis and are identical in every respect but housing and colour may be qualified through submission of test data for a single, representative model. Likewise, models that are unchanged or that differ only in finish from those sold in a previous year may remain qualified without the submission of new test data, assuming the specification remains unchanged.
The power requirement shall be measured from the outlet or power source to the product under test. The average true power consumption of the computer monitor shall be measured during the On Mode/Active Power, the Sleep Mode/Low Power, and the Off Mode/Standby Power. When performing measurements to self-certify a product model, the product being tested must initially be in the same condition (e.g., configuration and settings) as when shipped to the customer, unless adjustments need to be made pursuant to instructions below.
To ensure a consistent means for measuring the power consumption of electronics products, the following protocol must be followed, which has three main components:
Product Testing Set-up and Conditions: Outlined below in Sections 1(a) through (h) are the ambient test conditions and measurement protocols that must be respected when performing power measurements.
Product Testing Methodology: The actual test steps for measuring power in On Mode/Active Power, Sleep Mode/Low Power, and Off Mode/Standby Power are provided in Section 2(a), below.
Product Testing Documentation: Documentation requirements for submittal of qualified product data are detailed in Section 3, below.
This protocol ensures that outside factors do not adversely affect the test results and that the test results can be consistently reproduced. Manufacturers may elect to use an in-house or independent laboratory to provide the test results.
1. |
Product Testing Set-up and Conditions
|
2. |
Product Testing Methodology
|
3. |
Product Testing Documentation Submittal of Qualified Product Data: Partners are required to self-certify those product models that meet the Energy Star guidelines and report information on an ENERGY STAR QPI form. ENERGY STAR qualifying product data, including information about new as well as discontinued models, must be provided on an annual basis, or more frequently if desired by the manufacturer. |
E. User Interface
Manufacturers are strongly recommended to design products in accordance with the user interface standards being developed by the Power Management Controls project to make power controls more consistent and intuitive across all electronic devices. For details on this project, see http://eetd.LBL.gov/Controls.
III. PRINTER, FAX MACHINE, AND MAILING MACHINE SPECIFICATIONS
The following Printer, Fax Machine, and Mailing Machine Specifications shall be applicable until 31 March 2007.
A. Definitions
1. |
Printer: Imaging equipment, manufactured as a standard model, that serves as a hard-copy output device, and is capable of receiving information from single-user or networked computers. In addition, the unit must be capable of being powered from a wall outlet. This definition is intended to cover products that are advertised and sold as printers including printers that can be upgraded to a multifunction device (MFD) (10). |
2. |
Fax Machine: Imaging equipment, manufactured as a standard model, that serves as a hard copy output device whose primary function is sending and receiving information. Plain paper fax machines are covered under this Specification (e.g., ink jet/bubble jet, laser/LED, and thermal transfer). The unit must be capable of being powered from a wall outlet. This definition is intended to cover products that are advertised and sold as fax machines. |
3. |
Combination Printer/Fax Machine: Imaging equipment manufactured as a standard model that serves as both a fully-functional printer and fax machine, as defined above. This definition is intended to cover products that are marketed and sold as a combination printer/fax device. |
4. |
Mailing Machine: Imaging equipment that serves to print postage onto mail pieces. The unit must be capable of being powered from a wall outlet. This definition is intended to cover products that are advertised and sold as mailing machines. |
5. |
Print Speed: Pages per minute (ppm) measures the printing speed of a model. Print speed corresponds to the product's print speed as advertised by Program Participant. For Line Printers (e.g., dot matrix/impact printers), print speed is based on the method established in ISO 10561. For wide format printers designed to handle primarily A2 or 17″ × 32″ paper or larger, the print speed is specified in terms of monochrome text output at the default resolution. The print speed measured as A2 or A0-sized prints per minute, shall be converted into A4-sized print speeds as follows: (a) One A2 print per minute is equivalent to four A4 prints per minute; (b) One A0 print per minute is equivalent to 16 A4 prints per minute. For mailing machines, pages per minute (ppm) are considered equivalent to mail pieces per minute (ppm). |
6. |
Accessory: A piece of additional equipment that is not necessary for the standard operation of the base unit, but may be added before or after shipping in order to enhance or change printer performance. Examples of accessories include finishers, sorters, additional paper supply devices, and duplex units. An accessory may be sold separately under its own model number, or sold with a base unit as part of a printer. |
7. |
Active Mode: The condition (or mode) in which the product is producing hard copy output or receiving hard copy input. The power requirement in this mode is typically greater than the power requirement in standby mode. |
8. |
Standby Mode: The condition that exists when the product is not producing hard copy output or receiving hard copy input and is consuming less power than when producing such output or receiving such input. The transition from Standby Mode to Active Mode should cause no noticeable delay in the production of hard copy output. |
9. |
Sleep Mode: The condition that exists when the product is not producing hard copy output or receiving hard copy input and is consuming less power than when in standby mode. In the transition from Sleep Mode to Active Mode, there may be some delay in the production of hard copy output, however there shall be no delay in the acceptance of information from a network or other input sources. The product enters this mode within a specified time period after the last hard copy output was produced. |
10. |
Default Time To Sleep Mode: The time period set by the Program Participant prior to shipping that determines when the product will enter the Sleep Mode. The default time shall be measured from the time that the last piece of hard copy output was produced. |
11. |
Duplexing: The process of producing text, an image, or a combination of text and image on both sides of a single sheet of paper. |
12. |
Standard Model: The term used to describe a product and its bundled features as marketed and sold by the Program Participant and as manufactured for its intended use. |
13. |
Wake Event: As used in this agreement, a ‘wake event’ is defined as a user, programmed, or external event or stimulus that causes the unit to transition from its standby or Sleep Mode to its active mode of operation. A ‘wake event’ as defined in this Specification does not include network related polling queries or ‘pings’ that commonly occur in network environments. |
B. Product Qualification for ENERGY STAR
1. |
Technical Specifications
|
2. |
Exceptions and Clarifications After shipping, the ENERGY STAR Program Participant or its designated service representative shall not alter the models covered by this Specification in any way that will affect the products' ability to meet the specifications outlined above. Two exceptions follow:
|
C. Test Guidelines
1. |
Test Conditions: Outlined below are the ambient test conditions which should be established when performing the power measurement. These are necessary in order to ensure that outside factors do not affect the test results, and that test results can be reproduced later. Line Impedance: < 0.25 ohm Total Harmonic Distortion: < 5 % (Voltage) Ambient Temperature: 25 deg. C ±3 deg. C Input AC Voltage: 115 VAC RMS ±5 V RMS Input AC Frequency: 60 Hz ±3 Hz |
2. |
Testing Equipment: The provisions of Section I.C.2 apply. |
3. |
Test Method: The provisions of Section I.C.3 apply. |
IV. COPIER SPECIFICATIONS
The following Copier Specifications shall be applicable until 31 March 2007.
A. Definitions
1. |
Copier: A commercial reprographic imaging unit whose sole function is the production of duplicates from a graphic hard copy original. A copier must include a marking system, an imaging system, and a paper handling module. All black and white plain paper copier technologies are covered under this Specification, though the intent is to focus on widely-used standard copier equipment such as light lens copiers. The Specifications outlined below apply to standard-sized copiers designed to handle A4 or 8.5″ × 11″ paper and large format copiers designed to handle A2 or 17″ × 22″ paper or larger. |
2. |
Copier Speed: Copies per minute (cpm) measures the reproduction speed of the copier. One copy is defined as one 8.5″ × 11″ or A4-sized page. Double-sided copies are considered as two images and therefore two copies even though they are copied onto one piece of paper. For all copier models sold in the U.S. market, measurement of copier speed shall be based on 8.5″ × 11″ letter-sized paper. For copiers sold in markets other than the U.S., copier speed shall be based on either 8.5″ × 11″ or A4-sized paper, depending on which is standard in a particular market. For large format copiers designed to handle primarily A2 or 17″ × 22″ paper or larger, the copier speed measured as A2- or A0-sized copies per minute shall be converted to A4-sized copier speeds as follows: (a) One A2 copy per minute is equivalent to four A4 copies per minute, and (b) One A0 copy per minute is equivalent to 16 A4 copies per minute. Copiers qualified as ENERGY STAR shall be divided into five categories: low speed standard-sized copiers, medium speed standard-sized copiers, high speed standard-sized copiers, low speed large format copiers, and medium and high speed large format copiers.
|
3. |
Base Unit: For a given engine speed, the base unit is defined as the most basic version of a copier that is actually sold as a fully operational model. The base unit is typically designed and shipped in a single piece, and does not include any external power-consuming accessories that may be sold separately. |
4. |
Accessory: A piece of additional equipment that is not necessary for the standard operation of the base unit, but that may be added before or after shipping in order to enhance or change copier performance. An accessory may be sold separately under its own model number, or sold with a base unit as part of a copier package or configuration. Examples of accessories include: sorters, large capacity paper feeders, etc. It is assumed that the addition of an accessory, irrespective of its own power consumption, will not substantially increase (more than 10 percent) the off mode power consumption of the base unit. Any accessories shall not impede the normal operation of the auto-off and low-power features. |
5. |
Copier Model: For purposes of this Specification, a copier model is defined as a base unit and one or more specific accessories that are advertised and sold to consumers under a single model number. When advertised and sold to consumers without any additional accessories, a base unit is also considered a copier model. |
6. |
Low-Power Mode: For purposes of this Specification, the low-power mode is the lowest power state the copier can automatically enter within some period of copier inactivity, without actually turning off. The copier enters this mode within a specified period of time after the last copy was made. For purposes of determining the power consumption in this low-power mode, the company may choose to measure the lowest of either the energy-saver mode or the standby mode. |
7. |
Energy-Saver Mode: The condition that exists when the machine is not making copies, has previously reached operating conditions but is consuming less power than when the machine is in stand-by mode. When the copier is in this mode, there may be some delay before the copier will be capable of making the next copy. |
8. |
Standby Mode: The condition that exists when the machine is not making copies, has reached operating conditions and is ready to make a copy, but has not yet entered into energy-saver mode. When the copier is in this mode, there will be virtually no delay before the copier is capable of making the next copy. |
9. |
Off Mode: For purposes of this Specification, the off mode is defined as the condition that exists when the copier is connected to an appropriate electrical source, and has been recently shut off via the auto-off feature (14). When measuring power in this mode, control equipment for remote servicing may be excluded. |
10. |
Auto-off Feature: For purposes of this Specification, the auto-off feature is defined as the ability for the copier to automatically shut itself off within a specified period of time after the last copy was made. The copier shall automatically enter its off mode after execution of this feature. |
11. |
Plug-in Mode: The condition that exists when the machine is connected to an appropriate electrical source and is not turned on. To turn the copier on, the user typically needs to manually restart the copier via the on/off switch. |
12. |
Default Times: The time period set by the Program Participant prior to shipping that determines when the copier will enter its various modes, i.e., the low-power mode, the off mode, etc. Both the off mode default times and the low-power mode default times shall be measured from the time the last copy was made. |
13. |
Recovery Time: The amount of time needed to bring the copier from a low-power mode to the standby mode. |
14. |
Automatic Duplex Mode: The mode in which the copier automatically places images on both sides of a copy sheet, by automatically sending both the copy sheet and the graphic original through the copier model. Examples of this are one-sided to two-sided copying, or two-sided to two-sided copying. For purposes of this Specification, a copier model is considered to have an automatic duplex mode only if the copier model includes all accessories needed to satisfy the above conditions, i.e., an automatic document feeder and accessories for automatic duplexing capabilities. |
15. |
Weekly Timer: An internal device that turns a copier on and off at predetermined times each business day. When programming a timer, the customer shall be able to distinguish between business days and weekends/holidays (i.e., a timer shall not turn on a copier on Saturday and Sunday mornings if employees are not normally in the office on weekends). The customer shall also have the ability to disable the timer. Weekly timers are optional features, and therefore are not required on Energy Star compliant copiers. If included in copier models, weekly timers shall not conflict with the functioning of the low-power and auto-off features. |
B. Product Qualification for ENERGY STAR
1. |
Technical Specifications To qualify for ENERGY STAR, a copier shall meet the Specifications outlined below: Table 9 Criteria for ENERGY STAR Qualified Copiers
Program Participant shall set the default times for the auto-off feature to the levels specified in the Table above. The default times for the off mode and the low-power mode shall be measured from the time the last copy was made. For all copier speeds where it is optional that the duplex mode be set as the default, if a model is shipped with automatic duplexing capabilities, then it is recommended that duplexing be set as the default mode. Program Participant may provide users with the ability to override this default duplex mode for single-sided copies. |
2. |
Exceptions and Clarifications After shipping, Program Participant or its designated service representative shall not alter the copier model in any way that will affect the copier's ability to meet the specifications outlined above. Certain exceptions are allowed in changing the default times, the off mode specifications, and the duplex mode. These exceptions are as follows:
|
C. Test Guidelines
1. |
Test Conditions: Outlined below are the ambient test conditions which should be established when performing the power measurement. These are necessary in order to ensure that outside factors do not affect the test results, and that test results can be reproduced later. Line Impedance: < 0.25 ohm Total Harmonic Distortion: < 3 % Ambient Temperature: 21 deg. C ±3 deg. C Relative Humidity: 40 – 60 % Distance From Wall: 2 ft. min. Other Market-Specific Criteria:
|
2. |
Testing Equipment: The provisions of Section I.C 2 apply. |
3. |
Test Method: The provisions of Section I.C.3 apply. |
V. SCANNER SPECIFICATIONS
The following Scanner Specifications shall be applicable until 31 March 2007.
A. Definitions
1. |
Scanner: For purposes of this Specification, a scanner is defined as an electro-optical device for converting colour or black-and-white information into electronic images that can be stored, edited, converted, or transmitted primarily in a personal computing environment. Scanners defined as such are typically used for digitizing hard-copy images. The intent of this Specification is to focus on widely-used desktop scanners (e.g., flatbed, sheet-fed, and film scanners); however, high-end office document management scanners that meet the specifications outlined below may qualify for the Energy Star logo. This Specification is for stand-alone scanners; it does not cover multifunction products with scanning capabilities, network scanners (i.e., scanners that connect exclusively to a network and are capable of managing the scanned information for transmissions to multiple locations on the network), or scanners that are not powered directly by the building power supply. |
2. |
Base Unit: The base unit is defined as the most basic version of a scanner that is actually sold as a fully operational model. The base unit is typically designed and shipped in a single piece, and does not include any external power-consuming accessories that may be sold separately. |
3. |
Scanner Model: For purposes of this Specification, a scanner model is defined as a base unit and one or more specific accessories that are advertised and sold to consumers under a single model number. When advertised and sold to consumers without any additional accessories, a base unit is also considered a scanner model. |
4. |
Accessory: Any piece of additional equipment that is not necessary for the standard operation of the scanner, but that may be added in order to enhance or change scanner performance. An accessory may be sold separately under its own model number, or sold with a base unit as part of a scanner package or configuration. Examples of accessories include automatic document feeders (ADFs) and transparency adaptors. |
5. |
Low-power Mode: For purposes of this Specification, the low-power mode is the lowest power state the scanner is designed to enter after some period of inactivity, without actually turning off. The scanner enters this mode within a specified period of time after the last image was scanned. |
6. |
Default Time: The time period set by the Program Participant prior to shipping that determines when the scanner will enter the low-power mode. The low-power mode default time shall be measured from the time the last image was scanned. |
B. Product Qualification for ENERGY STAR
Technical Specifications: Program Participant agrees to introduce one or more specific base units that meet the specifications outlined below.
Table 10
Criteria for ENERGY STAR Qualified Scanners
Low-power Mode |
Low-power Mode Default Time |
≤ 12 watts |
≤ 15 minutes |
C. Test Guidelines
1. |
Test Conditions: Outlined below are the ambient test conditions which should be established when performing the power measurement. These are necessary in order to ensure that outside factors do not affect the test results, and that test results can be reproduced later. Line Impedance: < 0.25 ohm Total Harmonic Distortion: < 5 % Ambient Temperature: 25 deg. C ±3 deg. C Input AC Voltage: 115 VAC RMS ±5 V RMS Input AC Frequency: 60 Hz ±3 Hz |
2. |
Testing Equipment: The provisions of Section I.C.2 apply. |
3. |
Test Method: The provisions of Section I.C.3 apply. |
VI. MULTIFUNCTION DEVICE SPECIFICATIONS
The following Multi-function Device Specifications shall be applicable until 31 March 2007.
A. Definitions
1. |
Multifunction Device: A Multifunction Device (MFD) is a physically integrated device or a combination of functionally integrated components (the ‘base unit’, see definition below) that produces hard copy duplicates from graphical hard copy originals (distinct from single sheet convenience copying, see next paragraph) as well as performing one or both of the following core functions: printing of documents (from digital information received from direct connect computers, networked computers, file servers and fax transmissions) or faxing (send and receive). An MFD may also include scanning to computer file or any other capabilities not listed in this Specification. The device may be connected to a network, and may output black & white, grey scale, or colour images. EPA anticipates that a separate Specification may ultimately be required to cover colour devices, because of likely technological developments related to colour imaging, but for now these devices are included in this Specification. This Specification covers products that are marketed and sold as multifunction equipment whose primary function is copying but that are able to perform one or both of the additional core functions of printing or faxing. Devices whose primary function is faxing, and offer limited sheet copying capabilities (so-called single sheet ‘convenience copying’) are covered under the printer/fax Specification. If the MFD is not a single integrated unit but a set of functionally integrated components, then the manufacturer must certify that when installed correctly in the field the sum of all power use for all MFD components comprising the base unit will achieve the power levels listed below to qualify as an ENERGY STAR Qualified MFD. Some digital copiers can be upgraded into an MFD in the field with the installation of add-on devices that allow printing or faxing capabilities. Program Participants may consider this system of components to be an MFD, and may qualify it according to the specifications in Tables 11 and 12. However, when the digital copier is sold independently of the add-on devices, the copier must qualify according to the upgradeable digital copier specifications in Table 13 and 14. Some printers can be upgraded into an MFD in the field with the installation of add-on devices that allow copying (not just single sheet convenience copying) and may also allow faxing capabilities. Program Participants may consider this system of components to be an MFD, and may qualify it according to the MFD specifications. However, when sold independently, the printer cannot be represented as an ENERGY STAR qualified device unless it meets the ENERGY STAR specification for printers, in Section III. |
2. |
Image reproduction speed: Images per minute (ipm) measures the image reproduction speed specified in terms of monochrome text output per minute at the default resolution of the MFD. One image is defined as one 8.5″ × 11″ or A4-sized printed page of single-spaced monochrome text output, 12 point type, Times font, 1″ (2.54 cm) margins on all sides of the page. Double-sided prints or copies count as two images even though they are printed on one piece of paper. If at a later date EPA creates a test procedure specifically designed to measure print speed, then that test procedure shall supersede the output speed specifications listed in this section. For all multifunction device models, engine speed shall be based on either 8.5″ × 11″ or A4-sized paper, depending on which is the standard in a particular market. If copier and print speeds are different, whichever speed is higher shall be used to determine to which speed category the device belongs. For large format multifunction device models designed to handle primarily A2 or 17″ × 22″ paper or larger, the reproduction speed measured as A2 or A0-sized images per minute, shall be converted into A4-sized image reproduction speeds, as follows:
Multifunction Devices will be divided into the following categories: Personal Multifunction Devices: Multifunction devices with an engine speed for producing multiple images of 10 images per minute or less. Low Speed Multifunction Devices: Multifunction devices with an engine speed for producing multiple images of greater than 10 and less than or equal to 20 images per minute. Medium Speed Multifunction Devices: Multifunction devices with an engine speed for producing multiple images of greater than 20 and less than or equal to 44 images per minute. Medium/High Speed Multifunction Devices: Multifunction devices with an engine speed for producing multiple images of greater than 44 and less than or equal to 100 images per minute. High Speed Multifunction Devices (15) Multifunction devices with an engine speed for producing multiple images of greater than 100 images per minute. |
3. |
Base Unit: For a given engine speed, the base unit is defined as the most basic version of a multifunction device that is actually sold as a fully operational model. The base unit can be designed and shipped as a single piece or as a combination of functionally integrated components. The base unit must allow copying and one or both of the additional core functions of printing or faxing. The base unit does not include any external power-consuming accessories that may be sold separately. |
4. |
Accessories: A piece of additional equipment that is not necessary for the standard operation of the base unit, but that may be added before or after shipping in order to enhance or change multifunction device performance. Examples of accessories include: sorters, large capacity paper feeders, paper finishing equipment, large paper supply devices, output paper organisers, and key counters. An accessory may be sold separately under its own model number, or sold with a base unit as part of a multifunction device package or configuration. It is assumed that the addition of any accessories will not substantially increase (more than a total of 10 percent for all accessories) the low-power or sleep mode power consumption of the base unit (irrespective of the power consumption of the accessories). Any accessories shall not impede the normal operation of the low-power and sleep mode features. |
5. |
Multifunction Device Model: For purposes of this Specification, a multifunction device model is defined as a base unit and one or more specific accessories that are advertised and sold to consumers under a single model number. When advertised and sold to consumers without any additional accessories, a base unit is also considered a multifunction device model. |
6. |
Standby Mode: The condition that exists when the machine is not producing output, has reached operating conditions and is ready to make hard copy output, but has not yet entered into the low-power mode. When the multifunction device is in this mode, there will be virtually no delay before the multifunction device is capable of making the next hard copy output. |
7. |
Low-power Mode: For purposes of this Specification, the low-power mode is the condition that exists when the multifunction device is not producing hard copy output and is consuming less power than when in a standby mode. When the multifunction device is in this mode there may be some delay in the production of hard copy output. In this mode there shall be no delay in the acceptance of information from fax or printing or scanning input sources. The multifunction device enters this mode within a specified period of time after the last hard copy output was made no matter what the input source. For products that meet the low-power mode power requirements in standby mode, no further power reductions are required. |
8. |
Sleep Mode: For purposes of this Specification, the sleep mode is the lowest power state the multifunction device can automatically enter without actually turning off. In this mode both hard copy output and the acceptance of imaging information from some input ports may be delayed. The multifunction device enters the sleep mode within a specified period of time after the last hard copy output was made or after it has entered the low-power mode if a low-power mode is provided. |
9. |
Default Times: The time period set by the Program Participant prior to shipping that determines when the multifunction device will enter its various modes.(i.e., the low-power mode, the sleep mode, etc. Both the sleep mode default times and the low-power mode default times shall be measured from the time the last hard copy output was made.) |
10. |
Recovery Time: The amount of time needed to bring the multifunction device from the low- power mode to the standby mode. |
11. |
Automatic Duplex Mode: The mode in which the multifunction device automatically places images on both sides of a sheet by automatically sending both the sheet and the graphic original through the multifunction device. Examples of this are one-sided to two-sided copying, two-sided to two-sided copying, or double-sided printing. For purposes of this Specification, a multifunction device model is considered to have an automatic duplex mode only if the multifunction device model includes all accessories needed to satisfy the above conditions (i.e., an automatic document feeder and accessories for automatic duplexing capabilities). |
12. |
Weekly Timer: An internal device that turns a multifunction device on and off at predetermined times each day. When programming a timer, the customer shall be able to distinguish between business days and weekends/holidays (i.e., a timer shall not turn on a copier on Saturday and Sunday mornings if employees are not normally in the office on weekends). The customer shall also have the ability to disable the timer. Weekly timers are optional features, and therefore are not required on ENERGY STAR Qualified MFDs. If included in multifunction device models, weekly timers shall not conflict with the functioning of the low-power and sleep mode features. |
13. |
Upgradeable Digital Copier: A commercial reprographic imaging unit whose sole function is the production of duplicates from a graphic hard copy original using digital imaging technology, but that provides the option of being upgraded to offer multiple functions, such as printing or fax capabilities, through the installation of add-on devices. In order to be classified as an upgradeable digital copier under the MFD Specification, the upgrade options must be available on the market or intended for availability within one year after the base unit is launched. Digital copiers that are not designed for functional upgrades must qualify for ENERGY STAR under the Copier Specification. |
B. Product Qualification for ENERGY STAR
1. |
Technical Specifications ENERGY STAR Program Participant agrees to introduce one or more specific multifunction device models that meet the specifications outlined in the Tables below.
|
2. |
Additional requirements In addition to the requirements shown in Tables 11 through 14, the following additional requirements must also be met.
|
3. |
Exceptions and Clarifications: After shipping, Program Participant or its designated service representative shall not alter the multifunction device model in any way that will affect the multifunction device's ability to meet the specifications outlined above. Certain exceptions are allowed in changing the default times and the duplex mode. These exceptions are as follows:
|
C. Test Guidelines
1. |
Test Conditions Outlined below are the ambient test conditions which should be established when performing the power measurement. These are necessary in order to ensure that outside factors do not affect the test results, and that test results can be reproduced later. Line Impedance: < 0.25 ohm Total Harmonic Distortion: < 3 % Ambient Temperature: 21 deg. C ±3 deg. C Relative Humidity: 40 - 60 % Distance From Wall: 2 ft. min. Other Market-Specific Criteria:
|
2. |
Testing Equipment: The provisions of Section I.C.2 apply. |
3. |
Test Method: The provisions of Section I.C.3 apply. |
VII. IMAGING EQUIPMENT SPECIFICATION
The following Imaging Equipment Specifications shall be applicable as of 1 April 2007.
A. Definitions
Products
1. |
Copier: A commercially-available imaging product whose sole function is the production of hard copy duplicates from graphic hard copy originals. The unit must be capable of being powered from a wall outlet or from a data or network connection. This definition is intended to cover products that are marketed as copiers or upgradeable digital copiers (UDCs). |
2. |
Digital Duplicator: A commercially available imaging product that is sold in the market as a fully-automated duplicator system through the method of stencil duplicating with digital reproduction functionality. The unit must be capable of being powered from a wall outlet or from a data or network connection. This definition is intended to cover products that are marketed as digital duplicators. |
3. |
Facsimile Machine (Fax Machine): A commercially-available imaging product whose primary functions are scanning hard copy originals for electronic transmission to remote units and receiving similar electronic transmissions to produce hard copy output. Electronic transmission is primarily over a public telephone system, but also may be via computer network or the Internet. The product also may be capable of producing hard copy duplicates. The unit must be capable of being powered from a wall outlet or from a data or network connection. This definition is intended to cover products that are marketed as fax machines. |
4. |
Mailing Machine: A commercially-available imaging product that serves to print postage onto mail pieces The unit must be capable of being powered from a wall outlet or from a data or network connection. This definition is intended to cover products that are marketed as mailing machines. |
5. |
Multifunction Device (MFD): A commercially-available imaging product, which is a physically-integrated device or a combination of functionally-integrated components, that performs two or more of the core functions of copying, printing, scanning, or faxing. The copy functionality as addressed in this definition is considered to be distinct from single sheet convenience copying offered by fax machines. The unit must be capable of being powered from a wall outlet or from a data or network connection. This definition is intended to cover products that are marketed as MFDs or multifunction products (MFPs). Note: If the MFD is not a single integrated unit but a set of functionally integrated components, then the manufacturer must certify that when installed correctly in the field, the sum of all energy or power use for all MFD components comprising the base unit will achieve the energy or power levels provided in Section VII.C. to qualify as an ENERGY STAR MFD. |
6. |
Printer: A commercially-available imaging product that serves as a hard copy output device, and is capable of receiving information from single-user or networked computers, or other input devices (e.g., digital cameras). The unit must be capable of being powered from a wall outlet or from a data or network connection. This definition is intended to cover products that are marketed as printers, including printers that can be upgraded into MFDs in the field. |
7. |
Scanner: A commercially-available imaging product that functions as an electro-optical device for converting information into electronic images that can be stored, edited, converted, or transmitted, primarily in a personal computing environment. The unit must be capable of being powered from a wall outlet or from a data or network connection. This definition is intended to cover products that are marketed as scanners. |
Marking Technologies
8. |
Direct Thermal (DT): A marking technology that transfers an image by burning dots onto coated media as it passes over a heated print head. DT products do not use ribbons. |
9. |
Dye Sublimation (DS): A marking technology where images are formed by depositing (subliming) dye onto the print media based upon the amount of energy delivered by the heating elements. |
10. |
Electrophotography (EP): A marking technology characterised by illumination of a photoconductor in a pattern representing the desired hard copy image via a light source, development of the image with particles of toner using the latent image on the photoconductor to define the presence or absence of toner at a given location, transfer of the toner to the final hard copy medium, and fusing to cause the desired hard copy to become durable. Types of EP include Laser, LED, and LCD. Colour EP is distinguished from monochrome EP in that toners of at least three different colours are available in a given product at one time. Two types of colour EP technology are defined below:
|
11. |
Impact: A marking technology characterised by the formation of the desired hard copy image by transferring colorant from a ‘ribbon’ to the media via an impact process. Two types of impact technology are Dot Formed Impact and Fully-formed Impact. |
12. |
Ink Jet (IJ): A marking technology where images are formed by depositing colorant in small drops directly to the print media in a matrix manner. Colour IJ is distinguished from monochrome IJ in that more than one colorant is available in a product at any one time. Typical types of IJ include Piezo-electric (PE) IJ, IJ Sublimation, and Thermal IJ. |
13. |
Solid Ink (SI): A marking technology where the ink is solid at room temperature and liquid when heated to the jetting temperature. Transfer to the media can be direct, but is most often made to an intermediate drum or belt and then offset printed to the media. |
14. |
Stencil: A marking technology that transfers images onto the print media from a stencil that is fitted around an inked drum. |
15. |
Thermal Transfer (TT): A marking technology where the desired hard copy image is formed by depositing small drops of solid colorant (usually coloured waxes) in a melted/fluid state directly to the print media in a matrix manner. TT is distinguished from IJ in that the ink is solid at room temperature and is made fluid by heat. |
Operational Modes, Activities, and Power States
16. |
Active: The power state in which the product is connected to a power source and is actively producing output, as well as performing any of its other primary functions. |
17. |
Automatic Duplexing: The capability of a copier, fax machine, MFD, or printer to automatically place images on both sides of an output sheet, without manual manipulation of output as an intermediate step. Examples of this are one-sided to two-sided copying and two-sided to two-sided copying. A product is considered to have automatic duplexing capability only if the model includes all accessories needed to satisfy the above conditions. |
18. |
Default Delay Time: The time set by the manufacturer prior to shipping that determines when the product will enter a lower-power mode (e.g., Sleep, Off) following completion of its primary function. |
19. |
Off: The power state that the product enters when it has been manually or automatically switched off but is still plugged in and connected to the mains. This mode is exited when stimulated by an input, such as a manual power switch or clock timer to bring the unit into Ready mode. When this state is resultant from a manual intervention by a user, it is often referred to as Manual Off, and when it is resultant from an automatic or predetermined stimuli (e.g., a delay time or clock), it is often referred to as Auto-off. |
20. |
Ready: The condition that exists when the product is not producing output, has reached operating conditions, has not yet entered into any lower-power modes, and can enter Active mode with minimal delay. All product features can be enabled in this mode, and the product must be able to return to Active mode by responding to any potential input options designed into the product. Potential inputs include external electrical stimulus (e.g., network stimulus, fax call, or remote control) and direct physical intervention (e.g., activating a physical switch or button). |
21. |
Sleep: The reduced power state that the product enters automatically after a period of inactivity. In addition to entering Sleep automatically, the product may also enter this mode 1) at a user set time-of-day, 2) immediately in response to user manual action, without actually turning off, or 3) through other, automatically-achieved ways that are related to user behaviour. All product features can be enabled in this mode and the product must be able to enter Active mode by responding to any potential input options designed into the product; however, there may be a delay. Potential inputs include external electrical stimulus (e.g., network stimulus, fax call, remote control) and direct physical intervention (e.g., activating a physical switch or button). The product must maintain network connectivity while in Sleep, waking up only as necessary. Note: When reporting data and qualifying products that can enter Sleep mode in multiple ways, Program Participants should reference a Sleep level that can be reached automatically. If the product is capable of automatically entering multiple, successive Sleep levels, it is at the manufacturer's discretion which of these levels is used for qualification purposes; however, the default-delay time provided must correspond with whichever level is used. |
22. |
Standby: The lowest power consumption mode which cannot be switched off (influenced) by the user and that may persist for an indefinite time when the product is connected to the main electricity supply and used in accordance with the manufacturer's instructions (18). Note: For Imaging Equipment products addressed by this specification, the Standby power level usually occurs in Off mode, but can occur in Ready or Sleep. A product cannot exit Standby and reach a lower power state unless it is physically disconnected from the main electricity supply as a result of manual manipulation. |
Product Size Formats
23. |
Large Format: Products categorised as Large Format include those designed for A2 media and larger, including those designed to accommodate continuous-form media at a width of 406 millimetres (mm) or wider. Large-format products may also be capable of printing on standard-size or small-format media. |
24. |
Small Format: Products categorised as Small Format include those designed for media sizes smaller than those defined as Standard (e.g., A6, 4″ × 6″, microfilm), including those designed to accommodate continuous-form media at widths smaller than 210 mm. |
25. |
Standard: Products categorised as Standard include those designed for standard-sized media (e.g., Letter, Legal, Ledger, A3, A4, and B4), including those designed to accommodate continuous-form media at widths between 210 mm and 406 mm. Standard-size products may also be capable of printing on small-format media. |
Additional Terms
26. |
Accessory: An optional piece of peripheral equipment that is not necessary for the operation of the base unit, but that may be added before or after shipment in order to add functionality. An accessory may be sold separately under its own model number, or sold with a base unit as part of a package or configuration. |
27. |
Base Product: A base product is the standard model shipped by the manufacturer. When product models are offered in different configurations, the base product is the most fundamental configuration of the model, which possesses the minimum number of functional adders available. Functional components or accessories offered as optional, rather than standard, are not considered part of the base product. |
28. |
Continuous Form: Products categorised as Continuous Form include those which do not use a cut-sheet media size, and are designed for key industrial applications such as printing of bar codes, labels, receipts, waybills, invoices, airline tickets, or retail tags. |
29. |
Digital Front-end (DFE): A functionally-integrated, network-attached server or desktop-derived server that hosts other computers and applications and acts as an interface to imaging equipment. A DFE uses its own dc power supply or draws its dc power from the imaging equipment product with which it operates. A DFE provides greater functionality to the imaging product. A DFE also offers at least three of the following advanced features:
|
30. |
Functional Adder: A functional adder is a standard product feature that adds functionality to the base marking engine of an imaging equipment product. The Operational Mode portion of this specification contains additional power allowances for certain functional adders. Examples of functional adders include wireless interfaces and scanning capability. |
31. |
Operational Mode (OM) Approach: A method of testing and comparing the energy performance of imaging equipment products, which focuses on product energy consumption in various low-power modes. The key criteria used by the OM approach are values for low-power modes, measured in watts (W). Detailed information can be found in the Operational Mode Test Procedure in Section VII.D.3. |
32. |
Marking Engine: The very basic engine of an imaging product, which drives the image production of that product. Without additional functional components, a marking engine cannot acquire image data to process and is, therefore, non-functional. A marking engine is reliant on functional adders for communication ability and image processing. |
33. |
Model: An imaging equipment product that is sold or marketed under a unique model number or marketing name. A model may be comprised of a base unit or a base unit and accessories. |
34. |
Product Speed: In general, for Standard-size products, a single A4 or 8.5″ × 11″ sheet printed/copied/scanned on one side in a minute is equal to one image-per-minute (ipm). If the maximum claimed speeds differ when producing images on A4 or 8.5″ × 11″ paper, the higher of the two shall be used.
In all cases, the converted speed in ipm should be rounded to the nearest integer (e.g., 14.4 ipm rounds to 14.0 ipm; 14.5 ipm rounds to 15 ipm). For qualification purposes, manufacturers should report the speed of the product according to the prioritisation of functions outlined below:
|
35. |
Typical Electricity Consumption (TEC) Approach: A method of testing and comparing the energy performance of imaging equipment products, which focuses on the typical electricity consumed by a product while in normal operation during a representative period of time. The key criteria of the TEC approach for imaging equipment is a value for typical weekly electricity consumption, measured in kilowatt-hours (kWh). Detailed information can be found in the Typical Electricity Consumption Test Procedure in Section VII.D.2. |
B. Qualifying Products
In order to qualify as ENERGY STAR, an imaging equipment product must be defined in Section VII.A and meet one of the product descriptions in Table 15 or 16, below.
Table 15
Qualifying Products: TEC Approach
Product Area |
Marking Technology |
Size Format |
Colour Capability |
TEC Table |
Copiers |
Direct Thermal |
Standard |
Monochrome |
TEC 1 |
Dye Sublimation |
Standard |
Colour |
TEC 2 |
|
Dye Sublimation |
Standard |
Monochrome |
TEC 1 |
|
EP |
Standard |
Monochrome |
TEC 1 |
|
EP |
Standard |
Colour |
TEC 2 |
|
Solid Ink |
Standard |
Colour |
TEC 2 |
|
Thermal Transfer |
Standard |
Colour |
TEC 2 |
|
Thermal Transfer |
Standard |
Monochrome |
TEC 1 |
|
Digital Duplicators |
Stencil |
Standard |
Colour |
TEC 2 |
Stencil |
Standard |
Monochrome |
TEC 1 |
|
Fax Machines |
Direct Thermal |
Standard |
Monochrome |
TEC 1 |
Dye Sublimation |
Standard |
Monochrome |
TEC 1 |
|
EP |
Standard |
Monochrome |
TEC 1 |
|
EP |
Standard |
Colour |
TEC 2 |
|
Solid Ink |
Standard |
Colour |
TEC 2 |
|
Thermal Transfer |
Standard |
Colour |
TEC 2 |
|
Thermal Transfer |
Standard |
Monochrome |
TEC 1 |
|
Multifunction Devices (MFDs) |
Direct Thermal |
Standard |
Monochrome |
TEC 3 |
Dye Sublimation |
Standard |
Colour |
TEC 4 |
|
Dye Sublimation |
Standard |
Monochrome |
TEC 3 |
|
EP |
Standard |
Monochrome |
TEC 3 |
|
EP |
Standard |
Colour |
TEC 4 |
|
Solid Ink |
Standard |
Colour |
TEC 4 |
|
Multifunction Devices (MFDs) |
Thermal Transfer |
Standard |
Colour |
TEC 4 |
Thermal Transfer |
Standard |
Monochrome |
TEC 3 |
|
Printers |
Direct Thermal |
Standard |
Monochrome |
TEC 1 |
Dye Sublimation |
Standard |
Colour |
TEC 2 |
|
Dye Sublimation |
Standard |
Monochrome |
TEC 1 |
|
EP |
Standard |
Monochrome |
TEC 1 |
|
EP |
Standard |
Colour |
TEC 2 |
|
Solid Ink |
Standard |
Colour |
TEC 2 |
|
Thermal Transfer |
Standard |
Colour |
TEC 2 |
|
Thermal Transfer |
Standard |
Monochrome |
TEC 1 |
Table 16
Qualifying Products: Operational Mode Approach
Product Area |
Marking Technology |
Size Format |
Colour Capability |
OM Table |
Copiers |
Direct Thermal |
Large |
Monochrome |
OM 1 |
Dye Sublimation |
Large |
Colour & Monochrome |
OM 1 |
|
EP |
Large |
Colour & Monochrome |
OM 1 |
|
Solid Ink |
Large |
Colour |
OM 1 |
|
Thermal Transfer |
Large |
Colour & Monochrome |
OM 1 |
|
Fax Machines |
Ink Jet |
Standard |
Colour & Monochrome |
OM 2 |
Mailing Machines |
Direct Thermal |
N/A |
Monochrome |
OM 4 |
EP |
N/A |
Monochrome |
OM 4 |
|
Ink Jet |
N/A |
Monochrome |
OM 4 |
|
Thermal Transfer |
N/A |
Monochrome |
OM 4 |
|
Multifunction Devices (MFDs) |
Direct Thermal |
Large |
Monochrome |
OM 1 |
Dye Sublimation |
Large |
Colour & Monochrome |
OM 1 |
|
EP |
Large |
Colour & Monochrome |
OM 1 |
|
Ink Jet |
Standard |
Colour & Monochrome |
OM 2 |
|
Ink Jet |
Large |
Colour & Monochrome |
OM 3 |
|
Solid Ink |
Large |
Colour |
OM 1 |
|
Thermal Transfer |
Large |
Colour & Monochrome |
OM 1 |
|
Printers |
Direct Thermal |
Large |
Monochrome |
OM 8 |
Direct Thermal |
Small |
Monochrome |
OM 5 |
|
Dye Sublimation |
Large |
Colour & Monochrome |
OM 8 |
|
Dye Sublimation |
Small |
Colour & Monochrome |
OM 5 |
|
EP |
Large |
Colour & Monochrome |
OM 8 |
|
EP |
Small |
Colour |
OM 5 |
|
Impact |
Large |
Colour & Monochrome |
OM 8 |
|
Impact |
Small |
Colour & Monochrome |
OM 5 |
|
Impact |
Standard |
Colour & Monochrome |
OM 6 |
|
Ink Jet |
Large |
Colour & Monochrome |
OM 3 |
|
Ink Jet |
Small |
Colour & Monochrome |
OM 5 |
|
Ink Jet |
Standard |
Colour & Monochrome |
OM 2 |
|
Solid Ink |
Large |
Colour |
OM 8 |
|
Solid Ink |
Small |
Colour |
OM 5 |
|
Thermal Transfer |
Large |
Colour & Monochrome |
OM 8 |
|
Thermal Transfer |
Small |
Colour & Monochrome |
OM 5 |
|
Scanners |
N/A |
Large, Small & Standard |
N/A |
OM 7 |
C. Energy-Efficiency Specifications for Qualifying Products
Only those products listed in Section VII.B above that meet the following criteria may qualify as Energy Star.
Products Sold with an External Power Adapter: To qualify, imaging equipment products using a single-voltage external ac-dc or ac-ac power adapter must use an ENERGY STAR qualified adapter, or one that meets the ENERGY STAR External Power Supply (EPS) specification when tested to the ENERGY STAR test method on the date the imaging product is qualified as ENERGY STAR. The ENERGY STAR specification and test method for single voltage external ac-dc and ac-ac power supplies may be found at www.energystar.gov/products.
Products Designed to Operate with an External DFE: To qualify, an imaging equipment product that is sold with a DFE that uses its own ac power source must use an ENERGY STAR qualified DFE, or one that meets the ENERGY STAR Computer specification when tested to the ENERGY STAR test method on the date the imaging product is qualified as ENERGY STAR. The ENERGY STAR specification and test method for computers may be found at www.energystar.gov/products.
Products Sold with an Additional Cordless Handset: To qualify, fax machines or MFDs with fax capability that are sold with additional cordless handsets must use an ENERGY STAR qualified handset, or one that meets the ENERGY STAR Telephony specification when tested to the ENERGY STAR test method on the date the imaging product is qualified as ENERGY STAR. The ENERGY STAR specification and test method for telephony products may be found at www.energystar.gov/products.
Duplexing: Standard-size copiers, MFDs, and printers that use EP, SI, and heat-intensive IJ marking technologies addressed by the TEC approach in Section VII.C.1 must meet the following duplexing requirements, based on product speed:
Table 17
Duplexing Requirements for Colour Copiers, MFDs, and Printers
Product Speed |
Duplexing Requirement |
≤ 19 ipm |
N/A |
20 – 39 ipm |
Automatic duplexing must be offered as a standardfeature or optional accessory at the time of purchase. |
≥ 40 ipm |
Automatic duplexing is required as a standard feature at the time of purchase. |
Table 18
Duplexing Requirements for Monochrome Copiers, MFDs, and Printers
Product Speed |
Duplexing Requirement |
≤ 24 ipm |
N/A |
25 – 44 ipm |
Automatic duplexing must be offered as a standard feature or optional accessory at the time of purchase. |
≥ 45 ipm |
Automatic duplexing is required as a standard feature at the time of purchase. |
1. |
ENERGY STAR Eligibility Criteria – TEC. To qualify as Energy Star, the TEC value obtained for imaging equipment outlined in Section VII.B. Table 15 above must not exceed the corresponding criteria below. For imaging products with a functionally-integrated DFE that relies on the imaging product for its power, manufacturers should subtract the DFE's energy consumption in Ready mode from the product's total TEC result before comparing the product's TEC to the criteria limits below. In order to take advantage of this allowance, the DFE must meet the definition in Section VII.A.29. and be a separate processing unit that is capable of initiating activity over the network. Note: In all of the following equations, x = Product speed (ipm). Table 19 TEC Table 1
Table 20 TEC Table 2
Table 21 TEC Table 3
Table 22 TEC Table 4
|
2. |
ENERGY STAR Eligibility Criteria – OM To qualify as Energy Star, the power consumption values for imaging equipment outlined in Section VII.B. Table 16 above must not exceed the corresponding criteria below. For products that meet the Sleep-mode power requirement in Ready mode, no further automatic power reductions are required to meet the Sleep criterion. Additionally, for products that meet the Standby-power requirements in Ready or Sleep mode, no further power reductions are required to earn the ENERGY STAR. For imaging products with a functionally-integrated DFE that relies on the imaging product for its power, the power consumption of the DFE should be excluded when comparing the product's measured Sleep to the combined marking-engine and functional-adder criteria limits below. The DFE must not interfere with the ability of the imaging product to enter or exit its lower-power modes. In order to take advantage of this exclusion, the DFE must meet the definition in Section VII.A.29 and be a separate processing unit that is capable of initiating activity over the network. Default Delay Time Requirements: To qualify for ENERGY STAR, OM products must meet the default-delay time settings provided in Tables 23 through 25 below for each product type, enabled upon product shipment. In addition, all OM products must be shipped with a maximum machine delay time not in excess of four hours, which is only adjustable by the manufacturer. This maximum machine delay time cannot be influenced by the user and typically cannot be modified without internal, invasive product manipulation. The default-delay-time settings provided in Tables 23 through 25 may be user adjustable. Table 23 Maximum Default Delay Times to Sleep for Small-format and Standard-size OM Products, Excluding Mailing Machines, in Minutes
Table 24 Maximum Default Delay Times to Sleep for Large-format OM Products, Excluding Mailing Machines, in Minutes
Table 25 Maximum Default Delay Times to Sleep for Mailing Machines in Minutes
Standby Requirements: To qualify for ENERGY STAR, OM products must meet the Standby power criteria provided in Table 26 for each product type. Table 26 Maximum Standby Power Levels for OM Products in Watts
The eligibility criteria in OM Tables 1 through 8 (Tables 26-33) below address the marking engine of the product. Since products are expected to be shipped with one or more functions beyond a basic marking engine, the corresponding allowances below should be added to the marking engine criteria for Sleep. The total value for the base product with applicable ‘functional adders’ should be used to determine eligibility. Manufacturers may apply no more than three Primary functional adders to each product model, but may apply as many Secondary adders as present (with Primary adders in excess of three included as Secondary adders). An example of this approach is provided below: Table 27 Qualifying Products: OM Functional Adders
For the adder allowances shown in Qualifying Products Table 25 above, distinctions are made for ‘Primary’ and ‘Secondary’ types of adders. These designations refer to the state in which the interface is required to remain while the imaging product is in Sleep. Connections that remain active during the OM test procedure while the imaging product is in Sleep are defined as Primary, while connections that can be inactive while the imaging product is in Sleep are defined as Secondary. Most functional adders typically are Secondary types. Manufacturers should consider only the adder types that are available on a product in its as-shipped configuration. Options available to the consumer after the product is shipped or interfaces that are present on the product's externally-powered digital front-end (DFE) should not be considered when applying allowances to the imaging product. For products with multiple interfaces, these interfaces should be considered as unique and separate. However, interfaces that perform multiple functions should only be considered once. For example, a USB connection that operates as both 1.x and 2.x may be counted only once and given a single allowance. When a particular interface may fall under more than one interface Type according to the table, the manufacturer should choose the function that the interface is primarily designed to perform when determining the appropriate adder allowance. For example, a USB connection on the front of the imaging product that is marketed as a PictBridge or ‘camera interface’ in product literature should be considered a Type E interface rather than a Type B interface. Similarly, a memory-card-reader slot that supports multiple formats may only be counted once. Further, a system that supports more than one type of 802.11 may count as only one wireless interface. Table 28 OM Table 1
Table 29 OM Table 2
Table 30 OM Table 3
Table 31 OM Table 4
Table 32 OM Table 5
Table 33 OM Table 6
Table 34 OM Table 7
Table 35 OM Table 8
|
D. Testing Guidelines
The specific instructions for testing the energy efficiency of imaging equipment products are outlined in three separate sections below entitled:
— |
Typical Electricity Consumption Test Procedure; |
— |
Operational Mode Test Procedure; and |
— |
Test Conditions and Equipment for ENERGY STAR Imaging Equipment Products. |
The test results produced by these procedures shall be used as the primary basis for determining ENERGY STAR qualification.
Manufacturers are required to perform tests and self-certify those product models that meet the Energy Star guidelines. Families of imaging equipment models that are built on the same chassis and are identical in every respect except for housing and colour may be qualified through submission of test data for a single, representative model. Likewise, models that are unchanged or that differ only in finish from those sold in a previous year may remain qualified without the submission of new test data, assuming the specification remains unchanged.
If a product model is offered in the market in multiple configurations as a product ‘family’ or series, the partner may test and report the highest configuration available in the family, rather than each and every individual model. When submitting model families, manufacturers continue to be held accountable for any efficiency claims made about their imaging products, including those not tested or for which data was not reported.
If a product's electrical power comes from Mains, USB, IEEE1394, Power-over-Ethernet, telephone system, or any other means or combinations of means, the net AC electrical power consumed by the product (taking into account ac-to-dc conversion losses, as specified in the OM test procedure) must be used for qualification.
1. |
Additional testing and reporting requirements are provided below. Number of Units Required for Test Testing shall be conducted by the manufacturer or its authorised representative on a single unit of a model.
Submittal of Qualified Product Data to EPA or the European Commission, as appropriate Partners are required to self-certify those product models that meet the ENERGY STAR guidelines and report information to EPA or the European Commission, as appropriate. The information to be reported for products shall be outlined shortly following publication of the final specification. In addition, partners must submit to EPA or the European Commission, as appropriate, excerpts from product literature that explain to consumers the recommended default delay-times for power management settings. The intent of this requirement is to support that products are being tested as shipped and recommended for use. Models Capable of Operating at Multiple Voltage/Frequency Combinations Manufacturers shall test their products based on the market(s) in which the models will be sold and promoted as ENERGY STAR qualified. EPA, the European Commission and their ENERGY STAR Country Partners have agreed upon a table with three voltage/frequency combinations for testing purposes. Please refer to the Imaging Equipment Test Conditions for details regarding international voltage/frequency and paper sizes for each market. For products that are sold as ENERGY STAR in multiple international markets and therefore rated at multiple input voltages, the manufacturer must test at and report the required power consumption or efficiency values at all relevant voltage/frequency combinations. For example, a manufacturer that is shipping the same model to the United States and Europe must measure, meet the specification, and report test values at both 115 Volts/60 Hz and 230 Volts/50 Hz in order to qualify the model as ENERGY STAR in both markets. If a model qualifies as ENERGY STAR at only one voltage/frequency combination (e.g., 115 Volts/60 Hz), then it may only be qualified and promoted as ENERGY STAR in those regions that support the tested voltage/frequency combination (e.g., North America and Taiwan). |
2. |
Typical Electricity Consumption (TEC) Test Procedure
|
3. |
Operational Mode (OM) Test Procedure
|
4. |
Test Conditions and Equipment for ENERGY STAR Imaging Equipment Products The following test conditions shall be applied to the OM and TEC Test Procedures. These cover copiers, digital duplicators, fax machines, mailing machines, multifunction devices, printers, and scanners. Below are the ambient test conditions that must be established when performing the energy or power measurements. These are necessary to ensure that variance in ambient conditions does not affect the test results, and that test results are reproducible. Specifications for test equipment follow the test conditions.
|
E. User Interface
Manufacturers are strongly recommended to design products in accordance with IEEE 1621: Standard for User Interface Elements in Power Control of Electronic Devices Employed in Office/Consumer Environments. This standard was developed to make power controls more consistent and intuitive across all electronic devices. For details on the development of this standard, see http://eetd.lbl.gov/controls.
F. Effective Date
The date that manufacturers may begin to qualify products as ENERGY STAR under the Version 1.0 specification, will be defined as the effective date of the agreement. Any previously executed agreement on the subject of ENERGY STAR qualified imaging equipment shall be terminated effective March 31, 2007.
Qualifying and Labelling Products under Version 1.0:
The Version 1.0 specification shall commence on April 1, 2007, with the exception of digital duplicators. All products, including models originally qualified under previous imaging equipment specifications, with a date of manufacture on or after the effective date, must meet the new Version 1.0 requirements in order to qualify for ENERGY STAR (including additional manufacturing runs of models originally qualified under previous specifications). The date of manufacture is specific to each unit and is the date (e.g., month and year) on which a unit is considered to be completely assembled.
(a) |
Tier I – Tier I shall commence on April 1, 2007. Tier I applies to all products described in Section VII.B of this specification. |
(b) |
Tier II – Tier II shall commence on April 1, 2009. Tier II will apply to the maximum TEC levels for all TEC products, as well as to Standby levels for Large-format OM products and mailing machines. In addition, the definitions, products addressed, the manner in which they are addressed, and levels included for all products under this Version 1.0 specification may be reconsidered. EPA will inform stakeholders of plans to make such changes at most six months following the effective date of Tier I. |
(c) |
Digital Duplicators – Tier I of the Version 1.0 specification becomes effective for digital duplicators upon finalisation of the agreement between the European Community and the US EPA. |
Elimination of Grandfathering:
EPA and the European Commission will not allow grandfathering under this Version 1.0 ENERGY STAR specification. ENERGY STAR qualification under previous Versions is not automatically granted for the life of the product model. Therefore, any product sold, marketed, or identified by the manufacturing partner as ENERGY STAR must meet the current specification in effect at the time of manufacture of the product.
G. Future Specification Revisions
EPA and the European Commission reserve the right to change the specification should technological and/or market changes affect its usefulness to consumers, industry, or the environment. In keeping with current policy, revisions to the specification are arrived at through stakeholder discussions. EPA and the European Commission will periodically assess the market in terms of energy efficiency and new technologies. As always, stakeholders will have an opportunity to share their data, submit proposals, and voice any concerns. EPA and the European Commission will strive to ensure that the specification recognises the most energy efficient models in the marketplace and reward those manufacturers who have made efforts to further improve energy efficiency.
(a) |
Colour Testing: Based on submitted test data, future consumer preferences, and engineering advancements, EPA and the European Commission may modify this specification at some point in the future to include colour-imaging in the test method. |
(b) |
Recovery Time: EPA and the European Commission will closely monitor incremental and absolute recovery times as reported by partners testing to the TEC method, as well as partner-submitted documentation regarding recommended default delay settings. EPA and the European Commission will consider modification of this specification to address recovery time should it become apparent that manufacturer practices are resulting in user disabling of power management modes. |
(c) |
Addressing OM Products Under TEC: Based on submitted test data, opportunities for greater energy savings, and engineering advancements, EPA and the European Commission may modify this specification at some point in the future to address products that are currently treated by the OM approach under the TEC approach, including Large-format and Small-format products, as well as products that employ IJ technology. |
VIII. COMPUTER SPECIFICATIONS – REVISED FOR 2007
The following Computer specification shall be applicable as of 20 July 2007.
Below is the Version 4.0 product specification for ENERGY STAR qualified computers. A product must meet all of the identified criteria to earn the ENERGY STAR.
1. DEFINITIONS
Below are the definitions of the relevant terms in this document.
A. |
Computer: A device which performs logical operations and processes data. Computers are composed of, at a minimum: (1) a central processing unit (CPU) to perform operations; (2) user input devices such as a keyboard, mouse, digitiser or game controller; and (3) a display screen to output information. For the purposes of this specification, computers include both stationary and portable units, including desktop computers, gaming consoles, integrated computers, notebook computers, tablet PCs, desktop-derived servers and workstations. Although computers must be capable of using input devices and displays, as noted in numbers 2 and 3 above, computer systems do not need to include these devices on shipment to meet this definition. |
Components
B. |
Display: A commercially-available, electronic product with a display screen and its associated electronics encased in a single housing, or within the computer housing (e.g., notebook or integrated computer), that is capable of displaying output information from a computer via one or more inputs, such as a VGA, DVI, and/or IEEE 1394. Examples of display technologies are the cathode-ray tube (CRT) and liquid crystal display (LCD). |
C. |
External Power Supply: A component contained in a separate physical enclosure external to the computer casing and designed to convert line voltage ac input from the mains to lower dc voltage(s) for the purpose of powering the computer. An external power supply must connect to the computer via a removable or hard-wired male/female electrical connection, cable, cord or other wiring. |
D. |
Internal Power Supply: A component internal to the computer casing and designed to convert ac voltage from the mains to dc voltage(s) for the purpose of powering the computer components. For the purposes of this specification, an internal power supply must be contained within the computer casing but be separate from the main computer board. The power supply must connect to the mains through a single cable with no intermediate circuitry between the power supply and the mains power. In addition, all power connections from the power supply to the computer components must be internal to the computer casing (i.e., no external cables running from the power supply to the computer or individual components). Internal dc-to-dc converters used to convert a single dc voltage from an external power supply into multiple voltages for use by the computer are not considered internal power supplies. |
Computer Types
E. |
Desktop Computer: A computer where the main unit is intended to be located in a permanent location, often on a desk or on the floor. Desktops are not designed for portability and utilise an external monitor, keyboard, and mouse. Desktops are designed for a broad range of home and office applications including, email, web browsing, word processing, standard graphics applications, gaming, etc. |
F. |
Desktop-Derived Server: A desktop-derived server is a computer that typically uses desktop components in a tower form factor, but is designed explicitly to be a host for other computers or applications. For the purposes of this specification, a computer must be marketed as a server and have the following characteristics to be considered a desktop-derived server:
Desktop-derived servers are designed to perform functions such as processing information for other systems, providing network infrastructure services (e.g., archiving), data hosting and running web servers. This specification does not cover mid-range or large servers, defined for purposes of this specification as:
|
G. |
Game Consoles: Stand alone computers whose primary use is to play video games. For the purposes of this specification, game consoles must use a hardware architecture based on typical computer components (e.g., processors, system memory, video architecture, optical and/or hard drives, etc.). The primary input for game consoles are special hand held controllers rather than the mouse and keyboard used by more conventional computer types. Game consoles are also equipped with audio visual outputs for use with televisions as the primary display, rather than an external monitor or integrated display. These devices do not typically use a conventional operating system, but often perform a variety of multimedia functions such as: DVD/CD playback, digital picture viewing, and digital music playback. |
H. |
Integrated Computer: A desktop system in which the computer and display function as a single unit which receives its ac power through a single cable. Integrated computers come in one of two possible forms: (1) a system where the display and computer are physically combined into a single unit; or (2) a system packaged as a single system where the display is separate but is connected to the main chassis by a dc power cord and both the computer and display are powered from a single power supply. As a subset of desktop computers, integrated computers are typically designed to provide similar functionality as desktop systems. |
I. |
Notebook and Tablet Computers: A computer designed specifically for portability and to be operated for extended periods of time without a direct connection to an ac power source. Notebooks and tablets must utilise an integrated monitor and be capable of operation off an integrated battery or other portable power source. In addition, most notebooks and tablets use an external power supply and have an integrated keyboard and pointing device, though tablets use touch-sensitive screens. Notebook and tablet computers are typically designed to provide similar functionality to desktops except within a portable device. For the purposes of this specification, docking stations are considered accessories and therefore, the performance levels associated with notebooks presented in Table 41 of Section 3, below, do not include them. |
J. |
Workstation: For the purposes of this specification, to qualify as a workstation, a computer must:
In addition, a workstation must meet three of the following six optional characteristics:
|
Operational Modes
K. |
Idle State: For purposes of testing and qualifying computers under this specification, this is the state in which the operating system and other software have completed loading, the machine is not asleep, and activity is limited to those basic applications that the system starts by default. |
L. |
Sleep Mode: A low power state that the computer is capable of entering automatically after a period of inactivity or by manual selection. A computer with sleep capability can quickly ‘wake’ in response to network connections or user interface devices. For the purposes of this specification, Sleep mode correlates to ACPI System Level S3 (suspend to RAM) state, where applicable. |
M. |
Standby Level (Off Mode): The power consumption level in the lowest power mode which cannot be switched off (influenced) by the user and that may persist for an indefinite time when the appliance is connected to the main electricity supply and used in accordance with the manufacturer's instructions. For purposes of this specification, Standby correlates to ACPI System Level S4 or S5 states, where applicable. |
Networking and Power Management
N. |
Network Interface: The components (hardware and software) whose primary function is to make the computer capable of communicating over one or more network technologies. For purposes of testing to this specification, Network Interface refers to the IEEE 802.3 wired Ethernet interface. |
O. |
Wake Event: A user, programmed, or external event or stimulus that causes the computer to transition from Sleep or Standby to active mode of operation. Examples of wake events include, but are not limited to: movement of the mouse, keyboard activity, or a button press on the chassis, and in the case of external events, stimulus conveyed via a remote control, network, modem, etc. |
P. |
Wake On LAN (WOL): Functionality which allows a computer to wake from Sleep or Standby when directed by a network request. |
2. QUALIFYING PRODUCTS
Computers must meet the computer definition as well as one of the product type definitions provided in Section 1, above, to qualify as ENERGY STAR. Please note that EPA and the European Commission will explore additional computer types, such as thin clients, for potential Tier 2 requirements. The following table provides a list of the types of computers that are (and are not) eligible for ENERGY STAR.
Products Covered by Version 4.0 Specification |
Products Not Covered by Version 4.0 Specification |
(a) Desktop Computers (b) Game Consoles (c) Integrated Computer Systems (d) Notebook Computers/Tablet PCs (e) Desktop-Derived Servers (f) Workstations |
(g) Mid-Range and Large Servers (as defined in Section 1) F.) (h) Thin Clients/Blade PCs (c) Handhelds and PDAs |
3. ENERGY EFFICIENCY AND POWER MANAGEMENT CRITERIA
Computers must meet the requirements below to qualify as ENERGY STAR. Effective dates for Tier 1 and Tier 2 are covered in Section 5 of this specification.
A. Tier 1 Requirements – Effective July 20, 2007
1. |
Power Supply Efficiency Requirements Computers Using an Internal Power Supply: 80 % minimum efficiency at 20 %, 50 %, and 100 % of rated output and Power Factor > 0.9 at 100 % of rated output. Computers Using an External Power Supply: Must be ENERGY STAR qualified or meet the no-load and active mode efficiency levels provided in the ENERGY STAR Program Requirements for Single Voltage Ac-Ac and Ac-Dc External Power Supplies. The ENERGY STAR specification and qualified product list can be found at www.energystar.gov/powersupplies. Note: This performance requirement also applies to multiple voltage output external power supplies as tested in accordance to the Internal Power Supply test method referenced in Section 4, below. |
2. |
Operational Mode Efficiency Requirements Desktop Categories for Idle Criteria: For the purposes of determining Idle state levels, desktops (including integrated computers, desktop-derived servers and game consoles) must qualify under Categories A, B, or C as defined below: Category A: All desktop computers that do not meet the definition of either Category B or Category C below will be considered under Category A for ENERGY STAR qualification. Category B: To qualify under Category B desktops must have:
Category C: To qualify under Category C desktops must have:
In addition to the requirements above, models qualifying under Category C must be configured with a minimum of 2 of the following 3 characteristics:
Notebook Categories for Idle Criteria: For the purposes of determining Idle state levels, notebooks and tablets must qualify under Categories A or B as defined below: Category A: All notebook computers that do not meet the definition of Category B below will be considered under Category A for ENERGY STAR qualification. Category B: To qualify under Category B notebooks must have:
Workstation Levels: Workstation levels will be determined using a simplified Typical Electricity Consumption (TEC) approach to allow manufacturers energy trade offs between different operating modes, based on a given weighting factor for each mode. The final level will be based on the TEC power level (PTEC) which will be determined by the following formula: PTEC = 0.1 * PStandby + 0,2 * PSleep + 0,7 * PIdle where PStandby is the power measured in Standby, PSleep is the power measured in Sleep, and in PIdle is the power measured in Idle. This PTEC value will then be compared to the TEC budget which is determined by a fixed percentage of the maximum power of the system, including an adder for installed hard drives as indicated in the equation in Table 41. The test procedure for determining the maximum power of workstations can be found in Section 4 of Appendix A. Power Level Requirements: The following tables indicate the required power allowances for the Tier 1 specification. Table 41 gives the baseline requirements, while Table 42 gives additional power allowances for WOL. For those products that meet the WOL enabling requirement for either Sleep or Standby, a model must meet the energy level provided in Table 41 summed with the appropriate allowances from Table 42. Note: Products whose Sleep levels meet the Standby power requirements do not need to have a distinct Standby (Off mode), and may qualify for this specification using only Sleep mode. Table 41 Tier 1 Energy Efficiency Requirements
Table 42 Tier 1 Capability Adder for Sleep and Standby
Qualifying Computers with Power Management Capabilities: The following requirements should be followed when determining whether models should be qualified with or without WOL: Standby: Computers should be tested and reported as shipped for Standby. Models that will be shipped with WOL enabled for Standby should be tested with WOL enabled and will qualify using the extra allowance for Standby found in Table 42 above. Likewise, products shipped with WOL disabled for Standby must be tested with WOL disabled and must meet the baseline requirement for Standby found in Table 41. Sleep: Computers should be tested and reported as shipped for Sleep. Models sold through enterprise channels, as defined in the Tier 1 Power Management Requirements (Section 3.A.3), shall be tested, qualified, and shipped WOL enabled. Products going directly to consumers through normal retail channels are not required to be shipped with WOL enabled from Sleep, and may be tested, qualified, and shipped with WOL either enabled or disabled. Those models sold both through enterprise channels and directly to consumers must test and meet both the levels with and without WOL. Systems where any additional management services are, at the customer's request, pre-provisioned by the manufacturer, do not need to test the systems with these functions in an active state providing the function is not actually activated until there is specific action by the end user (i.e., manufacturer should test in pre-provisioned state and does not have to consider the power use after full provisioning occurs on site). |
3. |
Power Management Requirements Shipment Requirement: Products must be shipped with the display's Sleep mode set to activate within 15 minutes of user inactivity. All products, except for desktop-derived servers which are exempt from this requirement, must be shipped with a Sleep mode which is set to activate within 30 minutes of user inactivity. Products may have more than one low power mode but these proposed criteria address Sleep mode as defined in this specification. Computers shall reduce the speed of any active 1 Gb/s Ethernet network links when transitioning to Sleep or Standby. All computers, regardless of distribution channel, shall have the ability to enable and disable WOL for Sleep mode. Systems shipped through enterprise channels must have Wake On LAN (WOL) enabled from the Sleep mode when operating on ac power (i.e. notebooks may automatically disable WOL when operating on their portable power sources). For the purpose of this specification, ‘enterprise channels’ are defined as sales channels normally used by large and medium-sized business, government organisations, and educational institutions, with the intent of identifying machines that will be used in managed client/server environments. For all computers with WOL enabled any directed packet filters shall be enabled and set to an industry standard default configuration. Until one (or more) standards are agreed upon, partners are asked to provide their direct packet filter configurations to EPA for publication on the Website to stimulate discussion and development of standard configurations. Systems in which the Sleep mode maintains full network connectivity, providing the same fully connected network state found in Idle, can be considered to meet the WOL enabling requirement and may qualify using the corresponding WOL capability adder. All machines shipped to enterprise customers shall be capable of both remote and scheduled wake events from Sleep mode. Manufacturers shall ensure, where the manufacturer has control (i.e., configured through hardware settings rather than software settings), that these settings can be managed centrally, as the client wishes, with tools provided by the manufacturer. User Information Requirement: In order to ensure that purchasers/users are properly informed on the benefits of power management, the manufacturer will include with each computer, one of the following:
Either option must at least include the following information:
|
B. Tier 2 Requirements - Effective January 1, 2009
1a. |
Tier 2 Energy Efficiency Performance Metric All computers will be required to meet the following minimum performance per unit energy metric: Energy Efficiency Performance Software and Associated Levels: TBD - OR - |
1b. |
Provisional Tier 2 Idle State Requirements If an energy efficiency performance metric and associated performance levels are not ready to go into effect by January 1, 2009, a provisional Tier 2 specification will automatically go into effect and will remain in effect until such a benchmark is established. This provisional Tier 2 will include revised Idle state levels for all computer types (those included in Tier 1 as well as others as appropriate [e.g., thin clients]) with the intention of capturing the top 25 % performers in energy efficiency. Additional topics, including the following, will also be re-examined under a provisional Tier 2:
In the case of the implementation of a provisional Tier 2, EPA and the European Commission will re-examine these new topics and finalise new levels at least six months prior to the effective date for Tier 2. |
2. |
Power Management Requirements In addition to the requirements provided under Tier 1, above, ENERGY STAR qualified computers must maintain full network connectivity while in Sleep mode, according to a platform-independent industry standard. All computers shall reduce their network link speeds during times of low data traffic levels in accordance with any industry standards that provide for quick transitions among link rates. |
C. Voluntary Requirements
User Interface: Although not mandatory, manufacturers are strongly recommended to design products in accordance with the Power Control User Interface Standard – IEEE 1621 (formally known as ‘Standard for User Interface Elements in Power Control of Electronic Devices Employed in Office/Consumer Environments’). Compliance with IEEE 1621 will make power controls more consistent and intuitive across all electronic devices. For more information on the standard see http://eetd.LBL.gov/Controls.
4. TEST PROCEDURES
Manufacturers are required to perform tests and self-certify those models that meet the ENERGY STAR guidelines.
— |
In performing these tests, partner agrees to use the test procedures provided in Table 43, below. |
— |
The test results must be reported to EPA or the European Commission, as appropriate. |
Additional testing and reporting requirements are provided below.
A. |
Number of Units Required for Idle Testing: Manufacturers may initially test a single unit for qualification. If the initial unit tested meets the maximum power level for Idle but falls within 10 % of that level, one additional unit of the same model with an identical configuration must also be tested. Manufacturers shall report Idle values for both units. To qualify as ENERGY STAR, both units must meet the maximum Idle level for that product category. Note: This additional testing is only required for Idle qualification – only one unit is required to be tested for Sleep and Standby. The following example further illustrates this approach: Category A desktops must meet an Idle level of 50 watts or less, making 45 Watts the 10 % threshold for additional testing. The following scenarios could then occur when testing a model for qualification:
|
B. |
Models Capable of Operating at Multiple Voltage/Frequency Combinations: Manufacturers shall test their products based on the market(s) in which the models will be sold and promoted as ENERGY STAR qualified. EPA and its ENERGY STAR Country Partners have agreed upon a table with three voltage/frequency combinations for testing purposes. Please refer to the Test Conditions in the Test Procedure (Appendix A) for details regarding international voltage/frequency combinations for each market. For products that are sold as ENERGY STAR in multiple international markets and, therefore, rated at multiple input voltages, the manufacturer must test at and report the required power consumption or efficiency values at all relevant voltage/frequency combinations. For example, a manufacturer that is shipping the same model to the United States and Europe must measure, meet the specification, and report test values at both 115 Volts/60 Hz and 230 Volts/50 Hz in order to qualify the model as ENERGY STAR in both markets. If a model qualifies as ENERGY STAR at only one voltage/frequency combination (e.g., 115 Volts/60 Hz), then it may only be qualified and promoted as ENERGY STAR in those regions that support the tested voltage/frequency combination (e.g., North America and Taiwan). Table 43 Test Procedures for Measuring Operational Modes
|
C. |
Qualifying Families of Products: Models that are unchanged or that differ only in finish from those sold in a previous year may remain qualified without the submission of new test data assuming the specification remains unchanged. If a product model is offered in the market in multiple configurations or styles, as a product ‘family’ or series, the partner may report and qualify the product under a single model number, as long as all of the models within that family or series meet either of the following requirements:
|
5. EFFECTIVE DATE
The date that manufacturers may begin to qualify products as Energy Star, under this Version 4.0 specification, will be defined as the effective date of the agreement. Any previously executed agreement on the subject of Energy Star qualified computers shall be terminated effective July 19, 2007.
1. |
Qualifying Products Under Tier 1 of the Version 4.0 Specification: The first phase of this specification will commence on July 20, 2007. All products, including models originally qualified under Version 3.0, with a date of manufacture on or after July 20, 2007, must meet the new (Version 4.0) requirements in order to qualify for Energy Star. The date of manufacture is specific to each unit and is the date (e.g., month and year) of which a unit is considered to be completely assembled. |
2. |
Qualifying Products Under Tier 2 of the Version 4.0 Specification: The second phase of this specification, Tier 2, will commence on January 1, 2009. All products, including models originally qualified under Tier 1, with a date of manufacture on or after 1 January 2009, must meet the Tier 2 requirements in order to qualify for Energy Star. |
3. |
Elimination of Grandfathering: EPA and the European Commission will not allow grandfathering under this Version 4.0 Energy Star specification. Energy Star qualification under previous versions is not automatically granted for the life of the product model. Therefore, any product sold, marketed, or identified by the manufacturing partner as Energy Star must meet the current specification in effect at the time of manufacture of the product. |
6. FUTURE SPECIFICATION REVISIONS
EPA and the European Commission reserve the right to revise the specification should technological and/or market changes affect its usefulness to consumers or industry or its impact on the environment. In keeping with current policy, revisions to the specification will be discussed with stakeholders. In the event of a specification revision, please note that ENERGY STAR qualification is not automatically granted for the life of a product model. To qualify as ENERGY STAR, a product model must meet the ENERGY STAR specification in effect on the model's date of manufacture.
7. APPENDIX A: ENERGY STAR TEST PROCEDURE FOR DETERMINING THE POWER USE OF COMPUTERS IN STANDBY, SLEEP, IDLE AND MAXIMUM POWER
The following protocol should be followed when measuring power consumption levels of computers for compliance with the Standby, Sleep, and Idle levels provided in Annex VIII, Section 3) A) (2). Partners must measure a representative sample of the configuration as shipped to the customer. However, the Partner does not need to consider power consumption changes that may result from component additions, BIOS and/or software settings made by the computer user after sale of product. This procedure is intended to be followed in order and the mode being tested is labelled where appropriate.
I. Definitions
Unless otherwise specified, all terms used in this document are consistent with the definitions contained in Annex VIII, Section 1).
UUT
UUT is an acronym for ‘unit under test’, which in this case refers to the computer being tested.
UPS
UPS is an acronym for ‘Uninterruptible Power Supply’, which refers to a combination of converters, switches and energy storage means, for example batteries, constituting a power supply for maintaining continuity of load power in case of input power failure.
II. Testing Requirements
Approved Meter
Approved meters will include the following attributes (25):
— |
Power resolution of 1 mW or better; |
— |
An available current crest factor of 3 or more at its rated range value; and |
— |
Lower bound on the current range of 10mA or less. |
The following attributes in addition to those above are suggested:
— |
Frequency response of at least 3 kHz; and |
— |
Calibration with a standard that is traceable to the U.S. National Institute of Standards and Technology (NIST). |
It is also desirable for measurement instruments to be able to average power accurately over any user selected time interval (this is usually done with an internal math's calculation dividing accumulated energy by time within the meter, which is the most accurate approach). As an alternative, the measurement instrument would have to be capable of integrating energy over any user selected time interval with an energy resolution of less than or equal to 0.1 mWh and integrating time displayed with a resolution of 1 second or less.
Accuracy
Measurements of power of 0.5 W or greater shall be made with an uncertainty of less than or equal to 2 % at the 95 % confidence level. Measurements of power of less than 0.5 W shall be made with an uncertainty of less than or equal to 0.01 W at the 95 % confidence level. The power measurement instrument shall have a resolution of:
— |
0.01 W or better for power measurements of 10 W or less; |
— |
0.1 W or better for power measurements of greater than 10 W up to 100 W; and |
— |
1 W or better for power measurements of greater than 100 W. |
All power figures should be in watts and rounded to the second decimal place. For loads greater than or equal to 10 W, three significant figures shall be reported.
Test Conditions
Supply Voltage: |
North America/Taiwan: |
115 (±1 %) Volts AC, 60 Hz (±1 %) |
Europe/Australia/New Zealand: |
230 (±1 %) Volts AC, 50 Hz (±1 %) |
|
Japan: |
100 (±1 %) Volts AC, 50 Hz (±1 %)/60 Hz (±1 %) |
|
|
Note: For products rated for > 1.5 kW maximum power, the voltage range is ±4 % |
|
Total Harmonic Distortion (THD) (Voltage): |
< 2 % THD (< 5 % for products which are rated for > 1.5 kW maximum power) |
|
Ambient Temperature: |
23 °C ±5 °C |
|
Relative Humidity: |
10 – 80 % |
|
(Reference IEC 62301: Household Electrical Appliances – Measurement of Standby Power, Sections 3.2, 3.3) |
Test Configuration
Power consumption of a computer shall be measured and tested from an ac source to the UUT.
The UUT must be connected to an Ethernet network switch capable of the UUT's highest and lowest network speeds. The network connection must be live during all tests.
III. Test Procedure for Standby, Sleep and Idle for All Products
Measurement of ac power consumption of a computer should be conducted as follows:
UUT Preparation
1. |
Record the manufacturer and model name of the UUT. |
2. |
Ensure that the UUT is connected to a live Ethernet (IEEE 802.3) network switch as specified in Section II., ‘Test Configuration’, above, and that the connection is live. The computer must maintain this live connection to the switch for the duration of testing, disregarding brief lapses when transitioning between link speeds. |
3. |
Connect an approved meter capable of measuring true power to an ac line voltage source set to the appropriate voltage/frequency combination for the test. |
4. |
Plug the UUT into the measurement power outlet on the meter. No power strips or UPS units should be connected between the meter and the UUT. For a valid test to take place the meter should remain in place until all Standby, Sleep, and Idle power data is recorded. |
5. |
Record the ac voltage. |
6. |
Boot computer and wait until the operating system has fully loaded. |
7. |
If necessary, run the initial operating system setup and allow all preliminary file indexing and other one-time/periodic processes to complete. |
8. |
Record basic information about the computer's configuration – computer type, operating system name and version, processor type and speed, and total and available physical memory, etc (26). |
9. |
Record basic information about the video card - video card name, resolution, amount of onboard memory, and bits per pixel (27). |
10. |
Ensure that the UUT is configured as shipped including all accessories, power management settings, WOL enabling and software shipped by default. UUT should also be configured using the following requirements for all tests:
|
11. |
The following guidelines should be followed to configure power settings for displays (adjusting no other power management settings):
|
12. |
Shut down the computer. |
Standby (Off Mode) Testing
13. |
With the UUT shut down and in Standby, set the meter to begin accumulating true power values at an interval of 1 reading per second. Accumulate power values for 5 additional minutes and record the average (arithmetic mean) value observed during that 5 minute period (28). |
Idle Mode Testing
14. |
Switch on the computer and begin recording elapsed time, starting either when the computer is initially switched on, or immediately after completing any log in activity necessary to fully boot the system. Once logged in with the operating system fully loaded and ready, close any open windows so that the standard operational desktop screen or equivalent ready screen is displayed. Exactly 15 minutes after the initial boot or log in, set the meter to begin accumulating true power values at an interval of 1 reading per second. Accumulate power values for 5 additional minutes and record the average (arithmetic mean) value observed during that 5 minute period. |
Sleep Mode Testing
15. |
After completing the Idle measurements, place the computer in Sleep mode. Reset the meter (if necessary) and begin accumulating true power values at an interval of 1 reading per second. Accumulate power values for 5 additional minutes and record the average (arithmetic mean) value observed during that 5 minute period. |
16. |
If testing both WOL enabled and WOL disabled for Sleep, wake the computer and change the WOL from Sleep setting through the operating system settings or by other means. Place the computer back in Sleep mode and repeat step 14, recording Sleep power necessary for this alternate configuration. |
Reporting Test Results
17. |
The test results must be reported to EPA or the European Commission, as appropriate, taking care to ensure that all required information has been included. |
IV. Maximum Power Test for Workstations
The maximum power for workstations is found by the simultaneous operation of two industry standard benchmarks: Linpack to stress the core system (e.g., processor, memory, etc.) and SPECviewperf® (version 9.x or higher) to stress the system's GPU. Additional information on these benchmarks, including free downloads, can be found at the URLs found below:
Linpack |
http://www.netlib.org/linpack/ |
SPECviewperf® |
http://www.spec.org/benchmarks.html#gpc |
This test must be repeated three times on the same UUT, and all three measurements must fall within a ±2 % tolerance relative to the average of the three measured maximum power values.
Measurement of the maximum ac power consumption of a workstation should be conducted as follows:
UUT Preparation
1. |
Connect an approved meter capable of measuring true power to an ac line voltage source set to the appropriate voltage/frequency combination for the test. The meter should be able to store and output the maximum power measurement reached during the test or be capable of another method of determining maximum power. |
2. |
Plug the UUT into the measurement power outlet on the meter. No power strips or UPS units should be connected between the meter and the UUT. |
3. |
Record the ac voltage. |
4. |
Boot the computer and, if not already installed, install Linpack and SPECviewperf as indicated on the above Websites. |
5. |
Set Linpack with all the defaults for the given architecture of the UUT and set the appropriate array size ‘n’ for maximizing power draw during the test. |
6. |
Ensure all guidelines set by the SPEC organisation for running SPECviewperf are being met. |
Maximum Power Testing
7. |
Set the meter to begin accumulating true power values at an interval of 1 reading per second, and begin taking measurements. Run SPECviewperf and as many simultaneous instances of Linpack as needed to fully stress the system. |
8. |
Accumulate power values until SPECviewperf and all instances have completed running. Record the maximum power value attained during the test. |
Reporting Test Results
9. |
The test results must be reported to EPA or the European Commission, taking care to ensure that all required information has been included. |
10. |
Upon submittal of data, manufacturers must also include the following data:
|
V. Continuing Verification
This testing procedure describes the method by which a single unit may be tested for compliance. An ongoing testing process is highly recommended to ensure that products from different production runs are in compliance with ENERGY STAR.
(1) The maximum continuous output rating of a power supply is the value defined by the power supply manufacturer in the operating instructions provided with the product.
(2) If products will be sold in Europe or Asia, testing should also be performed at the appropriate machine-rated voltage and frequency. For example, products destined for European markets might be tested at 230 V and 50 Hz. The logo should not be displayed on products shipped to Europe or Asia if the equipment does not meet the power requirements of the Program at the local voltage and frequency conditions.
(3) Ibid.
(4) True power is defined as (volts)x(amps)x(power factor), and is typically reported as Watts. Apparent Power is defined as (volts)x(amps) and is usually expressed in terms of VA or volt-amps. The power factor for equipment with switching power supplies is always less that 1.0, so true power is always less than apparent power.
(5) The crest factor for a sinusoidal 60 Hz current waveform is always 1.4. The crest factor for a current waveform associated with a PC or monitor containing a switching power supply will always be greater than 1.4 (though typically no higher than 8). The crest factor of a current waveform is defined as the ratio of the peak current (amps) to the RMS current (amps).
(6) The crest factor of a watt meter is often provided for both current and voltage. For current it is the ratio of the peak current to the RMS current in a specific current range. When only one crest factor is given, it is usually for current. An average True RMS Wattmeter has a crest factor in the range of 2:1 to 6:1.
(7) This definition is consistent with IEC 62301: Household Electrical Appliances – Measurement of Standby power as of March 2004.
(8) Supply Voltage: Manufacturers shall test their computer monitors based on the market in which the models will be sold. Manufacturers must ensure that qualifying products marketed and sold in any region as ENERGY STAR do not exceed the power levels declared on the Qualifying Product Information (QPI) form (and stored in the ENERGY STAR database) at the standard mains voltage and frequency conditions of that region. For equipment that is sold in multiple international markets and therefore rated at multiple input voltages, the manufacturers must test at and report all relevant voltages and power consumption levels if it intends to register the product as ENERGY STAR in the respective markets. For example, a manufacturer that is shipping the same computer monitor model to the United States and Europe must measure and report the On, Sleep, and Off power consumption at both 115 Volts/60 Hz and 230 Volts/50 Hz.
(9) Corresponding voltage values for digital only interface monitors that correspond to the brightness of the image (0 to 0.7 volts) are:
0 volts (black) = a setting of 0
0.1 volts (darkest shade of gray analogue) = 36 digital gray
0.7 volts (full white analogue) = 255 digital gray
Please note that future digital interface specifications may widen this range, but in all cases, 0 volts shall correspond to black and the maximum value shall correspond to white, with 0.1 white volts corresponding to one-seventh of the maximum value.
(10) Note that once a printer base unit is upgraded to an MFD (for example, a photocopier unit is added), the entire product must qualify according to the ENERGY STAR MFD Specification in order for the product to remain ENERGY STAR qualified
(11) Including monochrome electrophotography, monochrome thermal transfer, and monochrome and colour ink jet.
(12) For printers that utilize a functionally integrated computer, whether contained within or outside of the printer cabinet, the power consumption of the computer does not have to be included when determining the Sleep Mode value of the printer unit. However, the integration of the computer must not interfere with the ability of the printer to enter or exit its Sleep Mode state. .
(13) Including colour electrophotography and colour thermal transfer.
(14) Section VII.B.1 of this Specification contains maximum power consumption targets for the off-mode. It is expected that most companies will meet these off-mode power consumption targets by incorporating an auto-off feature in the copier. However, it is possible and allowable under this Specification for a manufacturer to utilize a low-power mode, rather than and auto-off feature if the low-power mode power consumption is equal to or less than the off-mode power consumption targets contained in this Specification. (See Test Guidelines for more information on this issue.)
(15) For a multifunction device where the above method would give an inaccurate result (because the device is not completely warmed up after the first warm-up cycle plus 15 minutes standby time), the following procedure (in line with ASTM Standard F757-94) may be used:
Turn on the MFD and allow the machine to warm up and stabilize in the ready mode (= standby mode) for two hours. During the first 105 minutes, prevent the MFD from entering the low power mode (e.g., by making one copy every 14 minutes during this period). Make the last copy at 105 minutes after the MFD was turned on. Then wait exactly 15 minutes. After 15 minutes has passed, read and record the watt-hour meter indication and the time (or start the stopwatch or timer). After 1 hour, read and record the watt-hour indication again. The difference between the two readings of the watt-hour meter is the low-power mode energy use; divide by 1 hour to obtain the average power rating
(16) For MFDs that consist of functionally integrated, but physically separate units consisting of separate print, scan, and computer components, sleep mode Watts for the total system may be increased by an amount equal to the sleep mode Watts allowed for an ENERGY STAR qualified computer.
Note that criteria for upgradeable digital copiers are identical to those of the Copier Specification.
(17) For products registered with the European Commission, Program Participants may contact the European Commission.
(18) IEC 62301 – Household electrical appliances – Measurement of standby power. 2005.
(19) The type of network connection shall be reported. Common types are Ethernet, 802.11, and Bluetooth. Common non-network data connection types are USB, Serial, and Parallel.
(20) Interim Images/Day in Table 37.
(21) The type of network connection shall be reported. Common network types are Ethernet, WiFi (802.11), and Bluetooth. Common data (non-network) connection types are USB, Serial, and Parallel.
(22) Supply Voltage: Manufacturers shall test their products based on the market in which the partner intends to sell the products as ENERGY STAR qualified. For equipment that is sold in multiple international markets and therefore rated at multiple input voltages, the manufacturer must test at and report all relevant voltages and power consumption levels. For example, a manufacturer that is shipping the same printer model to the United States and Europe must measure and report the TEC or OM values at both 115 Volts/60 Hz and 230 Volts/50 Hz. If a product is designed to operate at a voltage/frequency combination in a specific market that is different from the voltage/frequency combination for that market (e.g., 230 Volts, 60 Hz in North America), the manufacturer should test the product at the regional combination that most closely matches the product's design capabilities and note this fact on the test reporting sheet.
(23) True power is defined as (volts)x(amps)x(power factor), and is typically reported as Watts. Apparent power is defined as (volts)x(amps), and is usually expressed in terms of VA or volt-amps. The power factor for equipment with switching power supplies is always less than 1.0, so true power is always less than apparent power. Accumulated energy measurements sums power measurements over a period of time and so also need to be based on measurements of true power.
(24) IEC 62301 – Household Electrical Appliances – Measurement of Standby Power 2005.
(25) Characteristics of approved meters taken from IEC 62301 Ed 1.0: Measurement of Standby Power
(26) On Windows-based machines, much of this information can be found by selecting the following: window: Start/Programs/Accessories/System Tools/System Information.
(27) On Windows-based machines, this can be found by selecting the following window: Start/Programs Accessories/System Tools/Components/Display.
(28) Laboratory-grade, full-function meters can integrate values over time and report the average value automatically. Other meters would require the user to capture a series of changing values every 5 seconds for a five minute period and then compute the average manually.