Choose the experimental features you want to try

This document is an excerpt from the EUR-Lex website

Document 32001Y0216(01)

Commission communication in the framework of the implementation of the Council Directive 94/9/EC (February 2001) (Text with EEA relevance)

OJ C 51, 16.2.2001, p. 6–8 (ES, DA, DE, EL, EN, FR, IT, NL, PT, FI, SV)

32001Y0216(01)

Commission communication in the framework of the implementation of the Council Directive 94/9/EC (February 2001) (Text with EEA relevance)

Official Journal C 051 , 16/02/2001 P. 0006 - 0008


Commission communication in the framework of the implementation of the Council Directive 94/9/EC

(February 2001)

(2001/C 51/03)

(Text with EEA relevance)

(Publication of titles and references of harmonised standards under the Directive)

CEN : rue de Stassart/Stassartstraat 36 , B - 1050 Brussels ; tel. (32-2) 550 08 11 , fax (32-2) 550 08 19 ( http://www.cenorm.be );

Cenelec : rue de Stassart/Stassartstraat 35 , B - 1050 Brussels ; tel. (32-2) 519 68 71 , fax (32-2) 519 69 19 ( http://www.cenelec.org );

ETSI : BP 152 , F - 06561 Valbonne Cedex , tel. (33-4) 92 94 42 12 , fax (33-4) 93 65 47 16 ( http://www.etsi.org ).

Note 1:

Generally the date of cessation of presumption of conformity will be the date of withdrawal ("dow"), set by the European standards body, but attention of users of these standards is drawn to the fact that in certain exceptional cases this can be otherwise.

Note 3:

In case of amendments, the referenced standard is EN CCCCC:YYYY, its previous amendments, if any, and the new, quoted amendment. The superseded standard (column 4) therefore consists of EN CCCCC:YYYY and its previous amendments, if any, but without the new quoted amendment. On the date stated, the superseded standard ceases to give presumption of conformity with the essential requirements of the directive.

Example: For EN 50014:1997, the following applies:

Cenelec

EN 50014:1997

Electrical apparatus for potentially explosive atmospheres - General requirements

(The referenced standard is EN 50014:1997)

NONE

(There is no superseded standard)

-

Amendment A1:1999 to EN 50014:1997

(The referenced standard is EN 50014:1997 +A1:1999 to EN 50014:1997)

Note 3

(The superseded standard is EN 50014:1997)

-

Amendment A2:1999 to EN 50014:1997

(The referenced standard is EN 50014:1997 +A1:1999 to EN 50014:1997 +A2:1999 to EN 50014:1997)

Note 3

(The superseded standard is EN 50014:1997 +A1:1999 to EN 50014:1997)

-

European standardisation organisation

Reference and title of the standard

Reference document

Reference of the superseded standard

Date of cessation of presumption of conformity of the superseded standard

Note 1

CEN

EN 1127-1-1997 Explosive atmospheres - Explosion prevention and protection - Part 1: Basic concepts and methodology

NONE

-

Cenelec

EN 50014:1997

Electrical apparatus for potentially explosive atmospheres - General requirements

NONE

-

Amendment A1:1999 to EN 50014:1997

Note 3

-

Amendment A2:1999 to EN 50014:1997

Note 3

-

Cenelec

EN 50015:1998

Electrical apparatus for potentially explosive atmospheres - Oil immersion "o"

NONE

-

Cenelec

EN 50017:1998

Electrical apparatus for potentially explosive atmospheres - Powder filling "q"

NONE

-

Cenelec

EN 50018:2000

Electrical apparatus for potentially explosive atmospheres - Flameproof enclosure "d"

NONE

-

Cenelec

EN 50019:2000

Electrical apparatus for potentially explosive atmospheres - Increased safety "e"

NONE

-

Cenelec

EN 50021:1999

Electrical apparatus for potentially explosive atmospheres - Type of protection "n"

NONE

-

Cenelec

EN 50054:1998

Electrical apparatus for the detection and measurement of combustible gases - General requirements and test methods

NONE

-

Cenelec

EN 50055:1998

Electrical apparatus for the detection and measurement of combustible gases - Performance requirements for Group I apparatus indicating up to 5 % (v/v) methane in air

NONE

-

Cenelec

EN 50056:1998

Electrical apparatus for the detection and measurement of combustible gases - Performance requirements for Group I apparatus indicating up to 100 % (v/v) methane in air

NONE

-

Cenelec

EN 50057:1998

Electrical apparatus for the detection and measurement of combustible gases - Performance requirements for Group II apparatus indicating up to 100 % lower explosive limit

NONE

-

Cenelec

EN 50058:1998

Electrical apparatus for the detection and measurement of combustible gases - Performance requirements for Group II apparatus indicating up to 100 % (v/v) gas

NONE

-

Cenelec

EN 50104:1998

Electrical apparatus for the detection and measurement of oxygen - Performance requirements and test methods

NONE

-

Cenelec

EN 50241-1:1999

Specification for open path apparatus for the detection of combustible or toxic gases and vapours - Part 1: General requirements and test methods

NONE

-

Cenelec

EN 50241-2:1999

Specification for open path apparatus for the detection of combustible or toxic gases and vapours - Part 2: Performance requirements for apparatus for the detection of combustible gases

NONE

-

Cenelec

EN 50281-1-1:1998

Electrical apparatus for use in the presence of combustible dust - Part 1-1: Electrical apparatus protected by enclosures - Construction and testing

NONE

-

Cenelec

EN 50281-1-2:1998

Electrical apparatus for use in the presence of combustible dust - Part 1-2: Electrical apparatus protected by enclosures - Selection, installation and maintenance + Corrigendum 12.1999

NONE

-

Cenelec

EN 50281-2-1:1998

Electrical apparatus for use in the presence of combustible dust - Part 2-1: Test methods - Methods for determining the minimum ignition temperatures of dust

NONE

-

Cenelec

EN 50284:1999

Special requirements for construction, test and marking of electrical apparatus of equipment group II, Category 1 G

NONE

-

Cenelec

EN 50303:2000

Group I, Category M1 equipment intended to remain functional in atmospheres endangered by firedamp and/or coal dust

NONE

-

Top