EUR-Lex Access to European Union law

Back to EUR-Lex homepage

This document is an excerpt from the EUR-Lex website

Document 52018XC0806(01)

Agreement between the European Community and the Swiss Confederation on mutual recognition in relation to conformity assessment, Annex 1, Chapter 5, Section 5, Point 9 ‘Information exchange’ — Information from Switzerland on the basis of Article 12 of the Agreement on the types of gas and the corresponding supply pressures of gaseous fuels on the Swiss territory referred to in Annex II of Regulation (EU) 2016/426 of the European Parliament and of the Council of 9 March 2016 on appliances burning gaseous fuels and repealing Directive 2009/142/EC (This publication is based on information received by the Commission from the Swiss Confederation)

OJ C 275, 6.8.2018, p. 1–2 (BG, ES, CS, DA, DE, ET, EL, EN, FR, GA, HR, IT, LV, LT, HU, MT, NL, PL, PT, RO, SK, SL, FI, SV)

6.8.2018   

EN

Official Journal of the European Union

C 275/1


Agreement between the European Community and the Swiss Confederation on mutual recognition in relation to conformity assessment, Annex 1, Chapter 5, Section 5, Point 9 ‘Information exchange’

Information from Switzerland on the basis of Article 12 of the Agreement on the types of gas and the corresponding supply pressures of gaseous fuels on the Swiss territory referred to in Annex II of Regulation (EU) 2016/426 of the European Parliament and of the Council of 9 March 2016 on appliances burning gaseous fuels and repealing Directive 2009/142/EC

(This publication is based on information received by the Commission from the Swiss Confederation)

(2018/C 275/01)

SWITZERLAND

Gas Family

2nd Family

3rd Family

Gas Group

Group H

Group P

Group B

 

minimum

maximum

minimum

nominal

maximum

minimum

nominal

maximum

Gross Calorific Value (GCV) [MJ/m3]

36,20

44,74

95,65

125,81

Wobbe index [MJ/m3]

48,82

53,48

76,84

87,33

Gas composition by volume in % of the total content:

 

minimum

nominal

maximum

minimum

nominal

maximum

minimum

nominal

maximum

C1 to C5 content (sum)

96

97,46

100

 (1)

100

 (1)

100

N2 + CO2 content

2,50

 (2)

 (2)

CO content

3,00

Unsaturated HC content

Hydrogen content

1,99

 (2)

 (2)

Information on toxic components contained in the gaseous fuel:

Tetrahydrothiophen (THT) in mg/Nm3 natural gas

10,0

30,0

Ethyl mercaptan (EM) in mg/Nm3 gas (Propane/Butane)

7,1

25,0

8,2

30,0

Carbonyl sulfide (COS) + elementary Sulfur in mg/kg (ppm) in (Propane/Butane)

5

5

Supply pressure:

 

minimum

nominal

maximum

minimum

nominal

maximum

minimum

nominal

maximum

Supply pressure at the inlet of appliances [mbar]

17,4

20,0

24,0

25,0

42,5

37,0

50,0

45,0

57,5

(25,0) (3)

25,0

42,5

(29,0) (3)

37,0

50,0

(35,0) (3)

45,0

57,5

Supply pressure at the point of delivery [mbar]

21,4

 (4)

 (5)

26,85

45,0

37,0

50,0

 (6)

(26,45) (3)

26,85

45,0

(29,0) (3)

37,0

50,0

 (6)

Admissible pressure loss in the end-user gas installation [mbar]

0

 (7)

4,0

0

 (7)

1,85

2,50

0

 (7)

(1,45) (3)

1,85

2,50

Reference conditions for Wobbe index and Gross Calorific Value (GCV)

Combustion reference temperature [°C]

15 °C

Volume measurement reference temperature [°C]

15 °C

Volume measurement reference pressure [mbar]

1,013 bar


(1)  In the content of C1-C5 (sum) only Propane respectively Butane must be min. 95 g/(100 g) in Weight-%.

(2)  The components (sum): Hydrogen + N2 + O2 + CH4 is max. 0,2 g/(100 g) in Weight-%.

(3)  Exception for Butane: Additional supply pressure of 28-30 mbar for gas categories I3+ and II2H3+.

(4)  Depends on the pressure loss up to the appliance.

(5)  Depends on the gas network operators.

(6)  Depends on the operating pressure range.

(7)  Depends on the diameter of the pipeline.