This document is an excerpt from the EUR-Lex website
Document 02006D0771(01)-20250123
Commission Decision of 9 November 2006 on harmonisation of the radio spectrum for use by short-range devices (notified under document number C(2006) 5304) (Text with EEA relevance) (2006/771/EC)
Consolidated text: Commission Decision of 9 November 2006 on harmonisation of the radio spectrum for use by short-range devices (notified under document number C(2006) 5304) (Text with EEA relevance) (2006/771/EC)
Commission Decision of 9 November 2006 on harmonisation of the radio spectrum for use by short-range devices (notified under document number C(2006) 5304) (Text with EEA relevance) (2006/771/EC)
02006D0771(01) — EN — 23.01.2025 — 009.001
This text is meant purely as a documentation tool and has no legal effect. The Union's institutions do not assume any liability for its contents. The authentic versions of the relevant acts, including their preambles, are those published in the Official Journal of the European Union and available in EUR-Lex. Those official texts are directly accessible through the links embedded in this document
|
COMMISSION DECISION of 9 November 2006 on harmonisation of the radio spectrum for use by short-range devices (notified under document number C(2006) 5304) (Text with EEA relevance) (OJ L 312 11.11.2006, p. 66) |
Amended by:
|
|
|
Official Journal |
||
|
No |
page |
date |
||
|
L 151 |
49 |
11.6.2008 |
||
|
L 119 |
32 |
14.5.2009 |
||
|
L 166 |
33 |
1.7.2010 |
||
|
L 329 |
10 |
13.12.2011 |
||
|
L 334 |
17 |
13.12.2013 |
||
|
COMMISSION IMPLEMENTING DECISION (EU) 2017/1483 of 8 August 2017 |
L 214 |
3 |
18.8.2017 |
|
|
COMMISSION IMPLEMENTING DECISION (EU) 2019/1345 of 2 August 2019 |
L 212 |
53 |
13.8.2019 |
|
|
COMMISSION IMPLEMENTING DECISION (EU) 2022/180 of 8 February 2022 |
L 29 |
17 |
10.2.2022 |
|
|
COMMISSION IMPLEMENTING DECISION (EU) 2025/105 of 22 January 2025 |
L 105 |
1 |
23.1.2025 |
|
Corrected by:
COMMISSION DECISION
of 9 November 2006
on harmonisation of the radio spectrum for use by short-range devices
(notified under document number C(2006) 5304)
(Text with EEA relevance)
(2006/771/EC)
Article 1
The purpose of this Decision is to harmonise the frequency bands and the related technical parameters for the availability and efficient use of radio spectrum for short-range devices so that such devices may benefit from ‘Class 1’ classification under Commission Decision 2000/299/EC.
Article 2
For the purpose of this Decision:
‘short-range device’ means a radio device which provides either unidirectional or bidirectional communication and which receives and/or transmits over a short distance at low power;
‘non-interference and non-protected basis’ means that no harmful interference may be caused to any radiocommunication service and that no claim may be made for protection of these devices against interference originating from radiocommunication services;
‘category of short-range devices’ means a group of short-range devices that use spectrum with similar technical spectrum access mechanisms or based on common usage scenarios.
Article 3
Article 4
Member States shall keep the use of the relevant bands under scrutiny and report their findings to the Commission to allow regular and timely review of the Decision.
Article 4a
Member States shall report to the Commission on the implementation of this Decision by ►M9 1 November 2025 ◄ at the latest.
Article 5
This Decision is addressed to the Member States.
ANNEX
Frequency bands with corresponding harmonised technical conditions and implementation deadlines for short-range devices
Table 1 defines the scope of different categories of short-range devices (defined in Article 2(3)) to which this Decision applies. Table 2 specifies different combinations of frequency band and category of short-range devices, and the harmonised technical conditions for spectrum access and implementation deadlines applicable thereto.
General technical conditions applicable to all bands and short-range devices that fall within the scope of this Decision:
For the purposes of this Annex, the following duty cycle definition applies:
‘ duty cycle ’ means the ratio, expressed as a percentage, of Σ(Ton)/(Tobs) where Ton is the ‘on’ time of a single transmitter device and Tobs is the observation period. Ton is measured in an observation frequency band (Fobs). Unless otherwise specified in this technical annex, Tobs is a continuous one hour period and Fobs is the applicable frequency band in this technical annex. Less restrictive conditions within the meaning of Article 3(3), mean that Member States may allow a higher value for ‘duty cycle’.
Table 1
Categories of short-range devices pursuant to Article 2(3) and their scope
|
Category of short-range devices |
Scope |
|
Non-specific short-range devices (SRD) |
Covers all kinds of radio devices, regardless of the application or their purpose, which fulfil the technical conditions as specified for a given frequency band. Typical uses include telemetry, telecommand, alarms, data transmissions in general and other applications. |
|
Active medical implant devices |
Covers the radio part of active implantable medical devices that are intended to be fully or partially introduced, surgically or medically, into the human body or that of an animal, and where applicable their peripherals. Active implantable medical devices are defined in Council Directive 90/385/EEC (1). |
|
Assistive listening devices (ALD) |
Covers radio communications systems that allow persons with hearing impairment to increase their listening capability. Typical system installations include one or more radio transmitters and one or more radio receivers. |
|
Audio Programme Making and Special Events (PMSE) devices |
Covers radio devices used for transmission of analogue or digital audio signals between a limited number of transmitters and receivers, such as radio microphones, in-ear monitors or audio links, used mainly for the production of broadcast programmes or private or public social or cultural events. |
|
Inductive devices |
Covers radio devices that use magnetic fields with inductive loop systems for near field communications and determination applications. This typically includes devices for car immobilisation, animal identification, alarm systems, cable detection, waste management, personal identification, wireless voice links, access control, proximity and metal sensors, anti-theft systems as well as RF anti-theft induction systems, data transfer to hand-held devices, automatic article identification, wireless control systems and automatic road tolling. |
|
Reliable alarm devices |
Covers radio devices that use radio communication support for indicating an alert to a system or a person, as a main functionality, at a distant location when a problem or a specific situation occurs. Radio alarms include social alarms and alarms for security and safety. |
|
Medical data acquisition devices |
Covers the transmission of non-voice data to and from non-implantable medical devices in order to monitor, diagnose and treat patients in healthcare facilities or in their homes as prescribed by duly authorised healthcare professionals. |
|
PMR446 devices |
Covers hand portable equipment (without base station or repeater use) carried on a person or manually operated, which uses integral antennas only in order to maximise sharing and minimise interference. PMR 446 equipment operates in short-range peer-to-peer mode and shall not be used as a part of infrastructure network nor as a repeater. |
|
Radio determination devices |
Covers radio devices used for determining the position, velocity and/or other characteristics of an object, or for obtaining information relating to these parameters. Radio determination equipment typically conducts measurements to obtain such characteristics. Radio determination devices exclude any kind of point-to-point or point-to-multipoint radio communications. |
|
Radio frequency identification (RFID) devices |
Covers tag/interrogator based radio communications systems, consisting of (i) radio devices (tags) attached to animate or inanimate items; and (ii) transmitter/receiver units (interrogators) which activate the tags and receive data back. Typical applications include the tracking and identification of items, for instance for the purpose of electronic article surveillance (EAS), and collecting and transmitting data relating to the items to which tags are attached, which may be either battery-less, battery assisted or battery powered. The responses from a tag are validated by its interrogator and passed to its host system. |
|
Transport and traffic telematics devices |
Covers radio devices that are used in the fields of transport (road, rail, water or air, depending on the relevant technical restrictions), traffic management, navigation, mobility management and in intelligent transport systems (ITS). Typical applications include interfaces between different modes of transport, communication between vehicles (e.g. car to car), between vehicles and fixed locations (e.g. car to infrastructure) as well as communication from and to users. |
|
Wideband data transmission devices |
Covers radio devices that use wideband modulation techniques to access the spectrum. Typical uses include wireless access systems such as radio local area networks (WAS/RLAN) or wideband SRD in data networks. |
|
(1)
Council Directive 90/385/EEC of 20 June 1990 on the approximation of the laws of the Member States relating to active implantable medical devices (OJ L 189, 20.7.1990, p. 17). |
|
Table 2
Frequency bands with corresponding harmonised technical conditions and implementation deadlines for short-range devices
|
Band No |
Frequency band |
Category of short-range devices |
Transmit power limit / field strength limit / power density limit |
Additional parameters (channelling and/or channel access and occupation rules) |
Other usage restrictions |
Implementation deadline |
|
1 |
9 -59,750 kHz |
Inductive devices |
72 dBμA/m at 10 metres |
|
|
1 July 2014 |
|
90 |
9 -148 kHz |
Radio determination devices |
46 dBμA/m at 10 metres at a reference of 100 Hz, outside the Nuclear Magnetic Resonance (NMR) device. Magnetic field strength descending 10 dB/decade above 100 Hz. |
|
For enclosed Nuclear Magnetic Resonance (NMR) applications [j]. |
1 July 2022 |
|
2 |
9 -315 kHz |
Active medical implant devices |
30 dBμA/m at 10 metres |
Duty cycle ≤ 10 % |
|
1 July 2014 |
|
3 |
59,750 -60,250 kHz |
Inductive devices |
42 dBμA/m at 10 metres |
|
|
1 July 2014 |
|
4 |
60,250 -74,750 kHz |
Inductive devices |
72 dBμA/m at 10 metres |
|
|
1 July 2014 |
|
5 |
74,750 -75,250 kHz |
Inductive devices |
42 dBμA/m at 10 metres |
|
|
1 July 2014 |
|
6 |
75,250 -77,250 kHz |
Inductive devices |
72 dBμA/m at 10 metres |
|
|
1 July 2014 |
|
7 |
77,250 -77,750 kHz |
Inductive devices |
42 dBμA/m at 10 metres |
|
|
1 July 2014 |
|
8 |
77,750 -90 kHz |
Inductive devices |
72 dBμA/m at 10 metres |
|
|
1 July 2014 |
|
9 |
90 -119 kHz |
Inductive devices |
42 dBμA/m at 10 metres |
|
|
1 July 2014 |
|
10 |
119 -128,6 kHz |
Inductive devices |
66 dBμA/m at 10 metres |
|
|
1 July 2014 |
|
11 |
128,6 -129,6 kHz |
Inductive devices |
42 dBμA/m at 10 metres |
|
|
1 July 2014 |
|
12 |
129,6 -135 kHz |
Inductive devices |
66 dBμA/m at 10 metres |
|
|
1 July 2014 |
|
13 |
135 -140 kHz |
Inductive devices |
42 dBμA/m at 10 metres |
|
|
1 July 2014 |
|
14 |
140 -148,5 kHz |
Inductive devices |
37,7 dBμA/m at 10 metres |
|
|
1 July 2014 |
|
15 |
148,5 -5 000 kHz [1 ] |
Inductive devices |
– 15 dBμA/m at 10 metres in any bandwidth of 10 kHz. Furthermore the total field strength is – 5 dΒμΑ/m at 10 metres for systems operating at bandwidths larger than 10 kHz. |
|
|
1 July 2014 |
|
91 |
148 -5 000 kHz |
Radio determination devices |
– 15 dBμA/m at 10 metres outside the Nuclear Magnetic Resonance (NMR) device. |
|
For enclosed Nuclear Magnetic Resonance (NMR) applications [j]. |
1 July 2022 |
|
16 |
315 -600 kHz |
Active medical implant devices |
– 5 dB μA/m at 10 metres |
Duty cycle ≤ 10 % |
This set of usage conditions is only available for animal implant devices. |
1 July 2025 |
|
17 |
400 -600 kHz |
Radio Frequency Identification (RFID) devices |
– 8 dBμA/m at 10 metres in any bandwidth of 10 kHz. Furthermore, the total field strength is – 5 dBμA/m at 10 metres for systems operating at bandwidths larger than 10 kHz. |
Bandwidth ≥ 30 kHz |
|
1 July 2025 |
|
85 |
442,2 -450,0 kHz |
Non-specific short-range devices |
7 dBμA/m at 10 metres |
Channel spacing ≥ 150 Hz |
This set of usage conditions is only available for person detection and collision avoidance devices. |
1 January 2020 |
|
18 |
456,9 -457,1 kHz |
Non-specific short-range devices |
7 dBμA/m at 10 metres |
|
This set of usage conditions is only available for emergency detections of buried victims and valuable items devices. |
1 July 2014 |
|
19 |
984 -7 484 kHz |
Transport and Traffic Telematics devices |
9 dBμA/m at 10 metres |
Duty cycle ≤ 1 % |
This set of usage conditions is only available for Eurobalise transmissions in the presence of trains using the 27 090 -27 100 kHz band for telepowering pursuant to the conditions set for band 28. |
1 July 2014 |
|
20 |
3 155 -3 400 kHz |
Inductive devices |
13,5 dBμA/m at 10 metres |
|
|
1 July 2014 |
|
21 |
5 000 -30 000 kHz [2 ] |
Inductive devices |
– 20 dBμA/m at 10 metres in any bandwidth of 10 kHz. Furthermore the total field strength is – 5 dΒμΑ/m at 10 metres for systems operating at bandwidths larger than 10 kHz. |
|
|
1 July 2014 |
|
92 |
5 000 -30 000 kHz |
Radio determination devices |
– 5 dBμA/m at 10 metres outside the Nuclear Magnetic Resonance (NMR) device. |
|
For enclosed Nuclear Magnetic Resonance (NMR) applications [j]. |
1 July 2022 |
|
22 |
6 765 -6 795 kHz |
Inductive devices |
42 dBμA/m at 10 metres |
|
|
1 July 2014 |
|
23 |
7 300 -23 000 kHz |
Transport and Traffic Telematics devices |
– 7 dBμA/m at 10 metres |
Antenna requirements apply [8]. |
This set of usage conditions is only available for Eurobalise transmissions in the presence of trains using the 27 090 -27 100 kHz band for telepowering pursuant to the conditions set for band 28. |
1 July 2014 |
|
24 |
7 400 -8 800 kHz |
Inductive devices |
9 dBμA/m at 10 metres |
|
|
1 July 2014 |
|
25 |
10 200 -11 000 kHz |
Inductive devices |
9 dBμA/m at 10 metres |
|
|
1 July 2014 |
|
26 |
12 500 -20 000 kHz |
Active medical implant devices |
– 7 dBμA/m at 10 metres in any bandwidth of 10 kHz |
Duty cycle ≤ 10 % |
This set of usage conditions is only available for indoor use by animal implant devices. |
1 July 2025 |
|
27a |
13 553 -13 567 kHz |
Inductive devices |
42 dBμA/m at 10 metres |
Transmission mask and antenna requirements for all combined frequency segments apply [8], [9]. |
|
1 January 2020 |
|
27b |
13 553 -13 567 kHz |
Radio Frequency Identification (RFID) devices |
60 dBμA/m at 10 metres |
Transmission mask and antenna requirements for all combined frequency segments apply [8], [9]. |
|
1 July 2014 |
|
27c |
13 553 -13 567 kHz |
Non-specific short-range devices |
10 mW e.r.p. |
|
|
1 July 2014 |
|
28 |
26 957 -27 283 kHz |
Non-specific short-range devices |
10 mW e.r.p. |
|
|
1 July 2014 |
|
29 |
26 990 -27 000 kHz |
Non-specific short-range devices |
100 mW e.r.p. |
Duty cycle ≤ 0,1 % Model control devices [d] may operate without duty cycle restrictions. |
|
1 July 2014 |
|
30 |
27 040 -27 050 kHz |
Non-specific short-range devices |
100 mW e.r.p. |
Duty cycle ≤ 0,1 % Model control devices [d] may operate without duty cycle restrictions. |
|
1 July 2014 |
|
31 |
27 090 -27 100 kHz |
Non-specific short-range devices |
100 mW e.r.p. |
Duty cycle ≤: 0,1 % Model control devices [d] may operate without duty cycle restrictions. |
|
1 July 2014 |
|
32 |
27 140 -27 150 kHz |
Non-specific short-range devices |
100 mW e.r.p. |
Duty cycle ≤ 0,1 % Model control devices [d] may operate without duty cycle restrictions. |
|
1 July 2014 |
|
33 |
27 190 -27 200 kHz |
Non-specific short-range devices |
100 mW e.r.p. |
Duty cycle ≤ 0,1 % Model control devices [d] may operate without duty cycle restrictions. |
|
1 July 2014 |
|
34 |
30 -37,5 MHz |
Active medical implant devices |
1 mW e.r.p. |
Duty cycle ≤ 10 % |
This set of usage conditions is only available for ultra-low power medical membrane implants for blood pressure measurements. |
1 July 2014 |
|
93 |
30 -130 MHz |
Radio determination devices |
– 36 dBm e.r.p. outside the Nuclear Magnetic Resonance (NMR) device. |
|
For enclosed Nuclear Magnetic Resonance (NMR) applications [j]. |
1 July 2022 |
|
35 |
40,66 -40,7 MHz |
Non-specific short-range devices |
10 mW e.r.p. |
|
|
1 January 2018 |
|
36 |
87,5 -108 MHz |
Non-specific short-range devices |
50 nW e.r.p. |
Bandwidth ≤ 200 kHz. |
This set of usage conditions is only available for audio transmitters with analogue frequency modulation (FM). |
1 July 2025 |
|
37a |
169,4 -169,475 MHz |
Assistive Listening Devices (ALD) |
500 mW e.r.p. |
|
|
1 July 2025 |
|
37c |
169,4 -169,475 MHz |
Non-specific short-range devices |
500 mW e.r.p. |
Duty cycle ≤ 1,0 % For metering devices [a], the duty cycle ≤ 10 % |
|
1 July 2025 |
|
38 |
169,4 -169,4875 MHz |
Non-specific short-range devices |
10 mW e.r.p. |
Duty cycle ≤ 0,1 % |
|
1 January 2020 |
|
39a |
169,4875 -169,5875 MHz |
Assistive Listening Devices (ALD) |
500 mW e.r.p. |
|
|
1 July 2025 |
|
39b |
169,4875 -169,5875 MHz |
Non-specific short-range devices |
10 mW e.r.p. |
Duty cycle ≤ 0,001 % Between 00:00h and 06:00h local time a duty cycle ≤ 0,1 % may be used. |
|
1 January 2020 |
|
40 |
169,5875 -169,8125 MHz |
Non-specific short-range devices |
10 mW e.r.p. |
Duty cycle ≤ 0,1 % |
|
1 January 2020 |
|
82 |
173,965 -216 MHz |
Assistive Listening Devices (ALD) |
10 mW e.r.p. |
On a tuning range basis [5]. A threshold of 35 dBμV/m is required to ensure the protection of a DAB receiver located at 1,5 metres from the ALD device, subject to DAB signal strength measurements taken around the ALD operating site. The ALD device should operate under all circumstances at least 300 kHz away from the channel edge of an occupied DAB channel. Requirements on techniques to access spectrum and mitigate interference apply [7]. |
|
1 July 2025 |
|
41 |
401 -402 MHz |
Active medical implant devices |
25 μW e.r.p. |
Bandwidth ≤ 100 kHz Requirements on techniques to access spectrum and mitigate interference apply [7]. Alternatively, a duty cycle limit of 0,1 % applies. |
This set of usage conditions is only available for systems specifically designed for the purpose of providing non-voice digital communications between active implantable medical devices and/or body-worn devices and other devices external to the human body used for transferring non-time-critical individual patient-related physiological information. |
1 July 2025 |
|
42 |
402 -405 MHz |
Active medical implant devices |
25 μW e.r.p. |
Bandwidth ≤ 300 kHz. Other techniques to access spectrum or mitigate interference, including bandwidths greater than 300 kHz, can be used provided they ensure compatible operation with the other users and in particular with meteorological radiosondes [7]. |
|
1 July 2025 |
|
43 |
405 -406 MHz |
Active medical implant devices |
25 μW e.r.p. |
Bandwidth ≤ 100 kHz Requirements on techniques to access spectrum and mitigate interference apply [7]. Alternatively, a duty cycle limit of 0,1 % applies. |
This set of usage conditions is only available for systems specifically designed for the purpose of providing non-voice digital communications between active implantable medical devices and/or body-worn devices and other devices external to the human body used for transferring non-time-critical individual patient-related physiological information. |
1 July 2025 |
|
86 |
430 -440 MHz |
Medical data acquisition devices |
– 50 dBm/100kHz e.r.p. power density but not exceeding a total power of – 40 dBm/10MHz (both limits are intended for measurement outside of the patient’s body) |
|
The set of usage conditions is only available for Ultra-Low Power Wireless Medical Capsule Endoscopy (ULP-WMCE) applications [h]. |
1 January 2020 |
|
44a |
433,05 -434,79 MHz |
Non-specific short-range devices |
1 mW e.r.p. |
|
|
1 July 2025 |
|
44b |
433,05 -434,79 MHz |
Non-specific short-range devices |
10 mW e.r.p. |
Duty cycle ≤ 10 % |
|
1 January 2020 |
|
45c |
434,04 -434,79 MHz |
Non-specific short-range devices |
10 mW e.r.p. |
Duty cycle ≤ 100 % subject to bandwidth ≤ 25 kHz. |
|
1 July 2025 |
|
83 |
446,0 -446,2 MHz |
PMR446 |
500 mW e.r.p. |
Requirements on techniques to access spectrum and mitigate interference apply [7]. |
|
1 January 2018 |
|
94 |
821,5 -826 MHz |
Audio PMSE devices |
100 mW e.i.r.p. for body-worn devices 20 mW e.i.r.p. for other devices |
|
|
1 July 2025 |
|
95 |
826 -832 MHz |
Audio PMSE devices |
100 mW e.i.r.p. |
|
|
1 July 2025 |
|
87 |
862 -863 MHz |
Non-specific short-range devices |
25 mW e.r.p. |
Duty cycle ≤ 0,1 % Bandwidth ≤ 350 kHz |
|
1 January 2020 |
|
46a |
863 -865 MHz |
Non-specific short-range devices |
25 mW e.r.p. |
Requirements on techniques to access spectrum and mitigate interference apply [7]. Alternatively, a duty cycle ≤ 0,1 % applies. |
|
1 January 2018 |
|
46b |
863 -865 MHz |
Audio PMSE devices |
10 mW e.r.p. |
|
This set of usage conditions is also available for personal cordless audio devices. |
1 July 2025 |
|
84 |
863 -868 MHz |
Wideband data transmission devices |
25 mW e.r.p. |
Requirements on techniques to access spectrum and mitigate interference apply [7]. Bandwidth > 600 kHz and ≤ 1 MHz Duty cycle ≤ 10 % for network access points [g] Duty cycle ≤ 2,8% otherwise |
This set of usage conditions is only available for wideband SRD in data networks [g]. |
1 January 2018 |
|
47 |
865 -868 MHz |
Non-specific short-range devices |
25 mW e.r.p. |
Requirements on techniques to access spectrum and mitigate interference apply [7]. Alternatively, a duty cycle ≤ 1 % applies. |
|
1 January 2020 |
|
47a |
865 -868 MHz [6 ] |
Radio Frequency Identification (RFID) devices |
Interrogator transmissions at 2 W e.r.p. only permitted within the channels centred at 865,7 MHz, 866,3 MHz, 866,9 MHz and 867,5 MHz RFID interrogator devices placed on the market before the repeal date of EC Decision 2006/804/EC are ‘grandfathered’, i.e. they are continuously permitted to be used in line with the provisions set out in EC Decision 2006/804/EC before the repeal date. |
Requirements on techniques to access spectrum and mitigate interference apply [7]. Bandwidth ≤ 200 kHz |
|
1 January 2018 |
|
47b |
865 -868 MHz |
Non-specific short-range devices |
500 mW e.r.p. Transmissions only permitted within the frequency ranges 865,6-865,8 MHz, 866,2-866,4 MHz, 866,8-867,0 MHz and 867,4-867,6 MHz, Adaptive Power Control (APC) required. Alternatively other mitigation technique with at least an equivalent level of spectrum compatibility. |
Requirements on techniques to access spectrum and mitigate interference apply [7]. Bandwidth ≤ 200 kHz Duty cycle ≤ 10 % for network access points [g] Duty cycle ≤ 2,5 % otherwise |
This set of usage conditions is only available for data networks [g]. |
1 January 2018 |
|
48 |
868 -868,6 MHz |
Non-specific short-range devices |
25 mW e.r.p. |
Requirements on techniques to access spectrum and mitigate interference apply [7]. Alternatively, a duty cycle ≤ 1 % applies. |
|
1 January 2020 |
|
49 |
868,6 -868,7 MHz |
Reliable alarm devices |
10 mW e.r.p. |
Bandwidth ≤ 25 kHz. The whole frequency band may also be used as a single channel. Duty cycle ≤ 1 % |
|
1 July 2025 |
|
50 |
868,7 -869,2 MHz |
Non-specific short-range devices |
25 mW e.r.p. |
Requirements on techniques to access spectrum and mitigate interference apply [7]. Alternatively, a duty cycle ≤ 0,1 % applies. |
|
1 January 2020 |
|
51 |
869,2 -869,25 MHz |
Reliable alarm devices |
10 mW e.r.p. |
Channel spacing: 25 kHz. Duty cycle ≤ 0,1 % |
This set of usage conditions is only available for social alarm devices [b]. |
1 July 2014 |
|
52 |
869,25 -869,3 MHz |
Reliable alarm devices |
10 mW e.r.p. |
Bandwidth ≤ 25 kHz Duty cycle ≤ 0,1 % |
|
1 July 2025 |
|
53 |
869,3 -869,4 MHz |
Reliable alarm devices |
10 mW e.r.p. |
Bandwidth ≤ 25 kHz Duty cycle ≤ 1 % |
|
1 July 2025 |
|
54 |
869,4 -869,65 MHz |
Non-specific short-range devices |
500 mW e.r.p. |
Requirements on techniques to access spectrum and mitigate interference apply [7]. Alternatively, a duty cycle ≤ 10 % applies. |
|
1 January 2020 |
|
55 |
869,65 -869,7 MHz |
Reliable alarm devices |
25 mW e.r.p. |
Bandwidth ≤ 25 kHz Duty cycle ≤ 10 % |
|
1 July 2025 |
|
56a |
869,7 -870 MHz |
Non-specific short-range devices |
5 mW e.r.p. |
|
|
1 July 2025 |
|
56b |
869,7 -870 MHz |
Non-specific short-range devices |
25 mW e.r.p. |
Requirements on techniques to access spectrum and mitigate interference apply [7]. Alternatively, a duty cycle ≤ 1 % applies. |
|
1 January 2020 |
|
96 |
1 785 -1 804,8 MHz |
Audio PMSE devices |
50 mW e.i.r.p. for body-worn devices or devices implementing Spectrum Scanning Procedure (SSP). 20 mW e.i.r.p. for other devices. |
|
|
1 July 2025 |
|
57a |
2 400 -2 483,5 MHz |
Non-specific short-range devices |
10 mW e.i.r.p. |
|
|
1 July 2014 |
|
57b |
2 400 -2 483,5 MHz |
Radio determination devices |
25 mW e.i.r.p. |
|
|
1 July 2014 |
|
57c |
2 400 -2 483,5 MHz |
Wideband data transmission devices |
100 mW e.i.r.p. and 100 mW/100 kHz e.i.r.p. density applies when frequency hopping modulation is used. 10 mW/MHz e.i.r.p. density applies when other types of modulation are used. |
Requirements on techniques to access spectrum and mitigate interference apply [7]. |
|
1 July 2014 |
|
58 |
2 446 -2 454 MHz |
Radio Frequency Identification (RFID) devices |
500 mW e.i.r.p. |
Requirements on techniques to access spectrum and mitigate interference apply [7]. |
|
1 July 2014 |
|
59 |
2 483,5 -2 500 MHz |
Active medical implant devices |
10 mW e.i.r.p. |
Requirements on techniques to access spectrum and mitigate interference apply [7]. Bandwidth ≤ 1 MHz. The whole frequency band may also be used dynamically as a single channel to maintain a communications session. Duty cycle ≤ 10 % for peripherals. |
Peripheral master units are for indoor use only. |
1 July 2025 |
|
59a |
2 483,5 -2 500 MHz |
Medical data acquisition devices |
1 mW e.i.r.p. |
Requirements on techniques to access spectrum and mitigate interference apply [7]. Bandwidth ≤ 3 MHz. Duty cycle ≤ 10 %. |
The set of usage conditions is only available for medical body area network system (MBANS) [f] for indoor use within healthcare facilities. |
1 January 2018 |
|
59b |
2 483,5 -2 500 MHz |
Medical data acquisition devices |
10 mW e.i.r.p. |
Requirements on techniques to access spectrum and mitigate interference apply [7]. Bandwidth ≤ 3 MHz. Duty cycle ≤ 2 %. |
The set of usage conditions is only available for medical body area network system (MBANS) [f] for indoor use within the patient’s home. |
1 January 2018 |
|
60 |
4 500 -7 000 MHz |
Radio determination devices |
24 dBm e.i.r.p. [3] |
Requirements on techniques to access spectrum and mitigate interference apply [7]. |
This set of usage conditions is only available for Tank Level Probing Radar [c]. |
1 July 2014 |
|
61 |
5 725 -5 875 MHz |
Non-specific short-range devices |
25 mW e.i.r.p. |
|
|
1 July 2014 |
|
62 |
5 795 -5 815 MHz |
Transport and Traffic Telematics devices |
2 W e.i.r.p. |
Requirements on techniques to access spectrum and mitigate interference apply [7]. |
This set of usage conditions applies only to road tolling applications and smart tachograph, weight and dimension applications [i]. |
1 January 2020 |
|
88 |
5 855 -5 865 MHz |
Transport and Traffic Telematics devices |
33 dBm e.i.r.p., 23 dBm/MHz e.i.r.p. density and a Transmit Power Control (TPC) able to reduce the total power from its maximum to 3 dBm e.i.r.p. |
Requirements on techniques to access spectrum and mitigate interference apply [7]. |
This set of usage conditions is only available for vehicle-to-vehicle, vehicle-to-infrastructure and infrastructure-to-vehicle systems. |
1 July 2025 |
|
89 |
5 865 -5 875 MHz |
Transport and Traffic Telematics devices |
33 dBm e.i.r.p., 23 dBm/MHz e.i.r.p. density and a Transmit Power Control (TPC) able to reduce the total power from its maximum to 3 dBm e.i.r.p. |
Requirements on techniques to access spectrum and mitigate interference apply [7]. |
This set of usage conditions is only available for vehicle-to-vehicle, vehicle-to-infrastructure and infrastructure-to-vehicle systems. |
1 July 2025 |
|
63 |
6 000 -8 500 MHz |
Radio determination devices |
7 dBm/50 MHz peak e.i.r.p. and – 33 dBm/MHz mean e.i.r.p. |
Automatic power control and antenna requirements as well as requirements on techniques to access spectrum and mitigate interference apply [7], [8] [10]. |
This set of usage conditions is only available for Level Probing Radar. Exclusion zones around radio astronomy sites shall apply. |
1 July 2014 |
|
64 |
8 500 -10 600 MHz |
Radio determination devices |
30 dBm e.i.r.p. [3] |
Requirements on techniques to access spectrum and mitigate interference apply [7]. |
This set of usage conditions is only available for Tank Level Probing Radar [c]. |
1 July 2014 |
|
65 |
17,1 -17,3 GHz |
Radio determination devices |
26 dBm e.i.r.p. |
Requirements on techniques to access spectrum and mitigate interference apply [7]. |
This set of usage conditions is only available for ground-based SAR systems [k]. |
1 July 2025 |
|
66 |
24,05 -24,075 GHz |
Transport and Traffic Telematics devices |
100 mW e.i.r.p. |
|
|
1 July 2014 |
|
67 |
24,05 -26,5 GHz |
Radio determination devices |
26 dBm/50 MHz peak e.i.r.p. and – 14 dBm/MHz mean e.i.r.p. |
Automatic power control and antenna requirements as well as requirements on techniques to access spectrum and mitigate interference apply [7]. [8], [10] |
This set of usage conditions is only available for Level Probing Radar. Exclusion zones around radio astronomy sites shall apply. |
1 July 2014 |
|
68 |
24,05 -27 GHz |
Radio determination devices |
43 dBm e.i.r.p. [3] |
Requirements on techniques to access spectrum and mitigate interference apply [7]. |
This set of usage conditions is only available for Tank Level Probing Radar [c]. |
1 July 2014 |
|
69a |
24,075 -24,15 GHz |
Transport and Traffic Telematics devices |
100 mW e.i.r.p. |
Requirements on techniques to access spectrum and mitigate interference apply [7]. |
This set of usage conditions is only available for ground-based vehicle radars. |
1 July 2014 |
|
69b |
24,075 -24,15 GHz |
Transport and Traffic Telematics devices |
0,1 mW e.i.r.p. |
|
|
1 July 2014 |
|
70a |
24,15 -24,25 GHz |
Non-specific short-range devices |
100 mW e.i.r.p. |
|
|
1 July 2014 |
|
70b |
24,15 -24,25 GHz |
Transport and Traffic Telematics devices |
100 mW e.i.r.p. |
|
|
1 July 2014 |
|
74a |
57 -64 GHz |
Non-specific short-range devices |
100 mW e.i.r.p. and a maximum transmit power of 10 dBm |
|
|
1 January 2020 |
|
74b |
57 -64 GHz |
Radio determination devices |
43 dBm e.i.r.p. [3] |
Requirements on techniques to access spectrum and mitigate interference apply [7]. |
This set of usage conditions is only available for Tank Level Probing Radar [c]. |
1 July 2014 |
|
74c |
57 -64 GHz |
Radio determination devices |
35 dBm/50 MHz peak e.i.r.p. and – 2 dBm/MHz mean e.i.r.p. |
Automatic power control and antenna requirements as well as requirements on techniques to access spectrum and mitigate interference apply [7] [8], [10]. |
This set of usage conditions is only available for Level Probing Radar. |
1 July 2014 |
|
75 |
57 -71 GHz |
Wideband data transmission devices |
40 dBm e.i.r.p. and 23 dBm/MHz e.i.r.p. density |
Requirements on techniques to access spectrum and mitigate interference apply [7]. |
Fixed outdoor installations are excluded. |
1 January 2020 |
|
75a |
57 -71 GHz |
Wideband data transmission devices |
40 dBm e.i.r.p., 23 dBm/MHz e.i.r.p. density and maximum transmit power of 27 dBm at the antenna port or ports |
Requirements on techniques to access spectrum and mitigate interference apply [7]. |
|
1 January 2020 |
|
75b |
57 -71 GHz |
Wideband data transmission devices |
55 dBm e.i.r.p., 38 dBm/MHz e.i.r.p. density and a transmit antenna gain ≥ 30 dBi |
Requirements on techniques to access spectrum and mitigate interference apply [7]. |
This set of usage conditions is only available for fixed outdoor installations. |
1 January 2020 |
|
76 |
61 -61,5 GHz |
Non-specific short-range devices |
100 mW e.i.r.p. |
|
|
1 July 2014 |
|
77 |
63,72 -65,88 GHz |
Transport and Traffic Telematics devices |
40 dBm e.i.r.p. |
TTT devices placed on the market before the 1 January 2020 are ‘grandfathered’, i.e. they are permitted to use the previous frequency range 63-64 GHz, and otherwise the same conditions apply. |
This set of usage conditions is only available to vehicle-to-vehicle, vehicle-to-infrastructure and infrastructure-to-vehicle systems. |
1 January 2020 |
|
97 |
69,8 -79,9 GHz |
Radio determination devices |
7 dBm e.i.r.p. |
|
This set of usage conditions is available for security scanners [l] operated indoors. |
1 July 2025 |
|
78a |
75 -85 GHz |
Radio determination devices |
34 dBm/50 MHz peak e.i.r.p. and – 3 dBm/MHz mean e.i.r.p. |
Automatic power control and antenna requirements as well as requirements on techniques to access spectrum and mitigate interference apply [7], [8], [10]. |
This set of usage conditions is only available for Level Probing Radar. Exclusion zones around radio astronomy sites shall apply. |
1 July 2014 |
|
78b |
75 -85 GHz |
Radio determination devices |
43 dBm e.i.r.p. [3] |
Requirements on techniques to access spectrum and mitigate interference apply [7]. |
This set of usage conditions is only available for Tank Level Probing Radar [c]. |
1 July 2014 |
|
79a |
76 -77 GHz |
Transport and Traffic Telematics devices |
55 dBm peak e.i.r.p. and 50 dBm mean e.i.r.p. and 23,5 dBm mean e.i.r.p. for pulse radars |
Requirements on techniques to access spectrum and mitigate interference apply [7]. Fixed transportation infrastructure radars have to be of a scanning nature in order to limit the illumination time and ensure a minimum silent time to achieve coexistence with automotive radar systems. |
This set of usage conditions is only available for ground-based vehicle and infrastructure systems. |
1 June 2020 |
|
79b |
76 -77 GHz |
Transport and Traffic Telematics devices |
30 dBm peak e.i.r.p. and 3 dBm/MHz average e.i.r.p. density |
Duty cycle ≤ 56 %/s |
This set of usage conditions is only available for obstacle detection systems for rotorcraft use [4]. Exclusion zones around radio astronomy sites shall apply. |
1 July 2025 |
|
98 |
76 -77 GHz |
Radio determination devices |
48 dBm mean e.i.r.p. and 18 dBm/MHz mean e.i.r.p. density |
Requirements on techniques to access spectrum and mitigate interference apply [7]. |
This set of usage conditions is only available for ground-based SAR systems [k]. Exclusion zones around radio astronomy sites shall apply. |
1 July 2025 |
|
99 |
76,5 -80,5 GHz |
Radio determination devices |
19 dBm peak e.i.r.p. |
At least 23 dB out-of-band attenuation relative to the maximum allowed peak e.i.r.p. is required. |
This set of usage conditions is only available for security scanners [l] operated indoors. |
1 July 2025 |
|
80a |
122 -122,25 GHz |
Non-specific short-range devices |
10 dBm/250 MHz e.i.r.p. and – 48 dBm/MHz at 30° elevation |
|
|
1 January 2018 |
|
80b |
122,25 -123 GHz |
Non-specific short-range devices |
100 mW e.i.r.p. |
|
|
1 January 2018 |
|
81 |
244 -246 GHz |
Non-specific short-range devices |
100 mW e.i.r.p. |
|
|
1 July 2014 |
Applications and devices referred to in Table 2:
[a] ‘Metering devices’ means radio devices that are part of bidirectional radio communications systems which allow remote monitoring, measuring and transmission of data in smart grid infrastructures, such as electricity, gas and water.
[b] ‘Social alarm devices’ means radio communications systems that allow reliable communication in a given area for a person in distress to initiate a call for assistance. Typical uses of social alarms are to assist elderly or disabled people.
[c] ‘Tank Level Probing Radar’ (TLPR) means a specific type of radiodetermination application, which is used for tank level measurements and is installed in metallic or reinforced concrete tanks, or similar structures made of material with comparable attenuation characteristics. The purpose of the tank is to contain a substance.
[d] ‘Model control devices’ means a specific kind of telecommand and telemetry radio equipment that is used to remotely control the movement of models (principally miniature representations of vehicles) in the air, on land or over or under the water surface.
[f] Medical Body Area Network Systems (MBANSs) are used for medical data acquisition and are intended for low-power wireless networking of a plurality of body-worn sensors and/or actuators as well as of a hub device placed on/around the human body.
[g] A network access point in a data network is a fixed terrestrial short-range device that acts as a connection point for the other short-range devices in the data network to service platforms located outside of that data network. The term data network refers to several short-range devices, including the network access point, as network components and to the wireless connections between them.
[h] Wireless medical capsule endoscopy is used for medical data acquisition designed for use in medical doctor-patient scenarios with the aim of acquiring images of human digestive tract.
[i] Smart tachograph, weight and dimension applications are defined as remote enforcement of the tachograph in Appendix 14 of Commission Implementing Regulation (EU) 2016/799 ( 1 ) and for the weights and dimensions enforcement in Article 10d of Directive (EU) 2015/719 of the European Parliament and of the Council ( 2 ).
[j] Enclosed NMR sensors are devices where the material/object under investigation is put inside the enclosure of the NMR device. NMR techniques use nuclear magnetic resonance excitation and magnetic field strength response of a material/object under test to get information about material properties based on resonance frequency responses of isotopes of atoms. Nuclear magnetic resonance imaging and magnetic resonance tomography systems are not included in this scope.
[k] Ground-based Synthetic Aperture Radar (SAR) systems are intended for deformation monitoring of terrain and natural or man-made structures, performed by interferometry radar.
[l] Security scanners are a specific type of radio determination applications which are used to detect objects carried by a person or on a person’s body for security screening purposes without making any physical contact.
Other technical requirements and clarifications referred to in Table 2:
[1] In band 20, higher field strengths and additional usage restrictions apply for inductive applications.
[2] In bands 22, 24, 25, 27a, and 28, higher field strengths and additional usage restrictions apply for inductive applications.
[3] The power limit applies inside a closed tank and corresponds to a spectral density of 41,3 dBm/MHz e.i.r.p. outside a 500 litre test tank.
[4] Member States can specify exclusion zones or equivalent measures in which the obstacle detection application for rotorcraft use shall not be used for the protection of the radioastronomy service or other national use. Rotorcraft is defined as EASA CS-27 and CS-29 (resp. JAR-27 and JAR-29 for former certifications).
[5] Devices shall implement the whole frequency range on a tuning range basis.
[6] RFID tags respond at a very low power level (-20 dBm e.r.p.) in a frequency range around the RFID interrogator channels and shall comply with the essential requirements of Directive 2014/53/EU.
[7] Techniques to access spectrum and mitigate interference that provide an appropriate level of performance to comply with the essential requirements of Directive 2014/53/EU shall be used. If relevant techniques are described in harmonised standards or parts thereof the references of which have been published in the Official Journal of the European Union under Directive 2014/53/EU, performance at least equivalent to these techniques shall be ensured.
[8] Antenna requirements that provide an appropriate level of performance to comply with the essential requirements of Directive 2014/53/EU shall be used. If relevant restrictions are described in harmonised standards or parts thereof the references of which have been published in the Official Journal of the European Union under Directive 2014/53/EU, performance at least equivalent to these restrictions shall be ensured.
[9] Transmission mask that provides an appropriate level of performance to comply with the essential requirements of Directive 2014/53/EU shall be used. If relevant restrictions are described in harmonised standards or parts thereof the references of which have been published in the Official Journal of the European Union under Directive 2014/53/EU, performance at least equivalent to these restrictions shall be ensured.
[10] Automatic power control that provides an appropriate level of performance to comply with the essential requirements of Directive 2014/53/EU shall be used. If relevant restrictions are described in harmonised standards or parts thereof the references of which have been published in the Official Journal of the European Union under Directive 2014/53/EU, performance at least equivalent to these restrictions shall be ensured.
( 1 ) Commission Implementing Regulation (EU) 2016/799 of 18 March 2016 implementing Regulation (EU) No 165/2014 of the European Parliament and of the Council laying down the requirements for the construction, testing, installation, operation and repair of tachographs and their components (OJ L 139, 26.5.2016, p. 1).
( 2 ) Directive (EU) 2015/719 of the European Parliament and of the Council of 29 April 2015 amending Council Directive 96/53/EC laying down for certain road vehicles circulating within the Community the maximum authorised dimensions in national and international traffic and the maximum authorised weights in international traffic (OJ L 115, 6.5.2015, p. 1).