Choose the experimental features you want to try

This document is an excerpt from the EUR-Lex website

Document 02013R0812-20180426

Consolidated text: Commission Delegated Regulation (EU) No 812/2013 of 18 February 2013 supplementing Directive 2010/30/EU of the European Parliament and of the Council with regard to the energy labelling of water heaters, hot water storage tanks and packages of water heater and solar device (Text with EEA relevance)

ELI: http://data.europa.eu/eli/reg_del/2013/812/2018-04-26

02013R0812 — EN — 26.04.2018 — 003.001


This text is meant purely as a documentation tool and has no legal effect. The Union's institutions do not assume any liability for its contents. The authentic versions of the relevant acts, including their preambles, are those published in the Official Journal of the European Union and available in EUR-Lex. Those official texts are directly accessible through the links embedded in this document

►B

COMMISSION DELEGATED REGULATION (EU) No 812/2013

of 18 February 2013

supplementing Directive 2010/30/EU of the European Parliament and of the Council with regard to the energy labelling of water heaters, hot water storage tanks and packages of water heater and solar device

(Text with EEA relevance)

(OJ L 239 6.9.2013, p. 83)

Amended by:

 

 

Official Journal

  No

page

date

►M1

COMMISSION DELEGATED REGULATION (EU) No 518/2014 of 5 March 2014

  L 147

1

17.5.2014

►M2

COMMISSION DELEGATED REGULATION (EU) 2017/254 of 30 November 2016

  L 38

1

15.2.2017

 M3

COMMISSION DELEGATED REGULATION (EU) 2018/543 of 23 January 2018

  L 90

63

6.4.2018




▼B

COMMISSION DELEGATED REGULATION (EU) No 812/2013

of 18 February 2013

supplementing Directive 2010/30/EU of the European Parliament and of the Council with regard to the energy labelling of water heaters, hot water storage tanks and packages of water heater and solar device

(Text with EEA relevance)



Article 1

Subject matter and scope

1.  
This Regulation establishes requirements for the energy labelling of, and the provision of supplementary product information on, water heaters with a rated heat output ≤ 70 kW, hot water storage tanks with a storage volume ≤ 500 litres and packages of water heater ≤ 70 kW and solar device.
2.  

This Regulation shall not apply to:

(a) 

water heaters specifically designed for using gaseous or liquid fuels predominantly produced from biomass;

(b) 

water heaters using solid fuels;

(c) 

water heaters within the scope of Directive 2010/75/EU of the European Parliament and of the Council ( 1 );

(d) 

combination heaters as defined in Article 2 of Commission Delegated Regulation (EU) No 811/2013 ( 2 );

(e) 

water heaters which do not meet at least the load profile with the smallest reference energy, as specified in Annex VII, Table 3;

(f) 

water heaters designed for making hot drinks and/or food only.

Article 2

Definitions

In addition to the definitions set out in Article 2 of Directive 2010/30/EU, the following definitions shall apply for the purposes of this Regulation:

(1) 

‘water heater’ means a device that:

(a) 

is connected to an external supply of drinking or sanitary water;

(b) 

generates and transfers heat to deliver drinking or sanitary hot water at given temperature levels, quantities and flow rates during given intervals; and

(c) 

is equipped with one or more heat generators;

(2) 

‘heat generator’ means the part of a water heater that generates the heat using one or more of the following processes:

(a) 

combustion of fossil fuels and/or biomass fuels;

(b) 

use of the Joule effect in electric resistance heating elements;

(c) 

capture of ambient heat from an air source, water source or ground source, and/or waste heat;

(3) 

‘rated heat output’ means the declared heat output of the water heater when providing water heating at standard rating conditions, expressed in kW;

(4) 

‘storage volume’ (V) means the rated volume of a hot water storage tank, expressed in litres;

(5) 

‘standard rating conditions’ means the operating conditions of water heaters for establishing the rated heat output, water heating energy efficiency and sound power level, and of hot water storage tanks for establishing the standing loss;

(6) 

‘biomass’ means the biodegradable fraction of products, waste and residues from biological origin from agriculture (including vegetal and animal substances), forestry and related industries including fisheries and aquaculture, as well as the biodegradable fraction of industrial and municipal waste;

(7) 

‘biomass fuel’ means a gaseous or liquid fuel produced from biomass;

(8) 

‘fossil fuel’ means a gaseous or liquid fuel of fossil origin;

(9) 

‘hot water storage tank’ means a vessel for storing hot water for water and/or space heating purposes, including any additives, which is not equipped with any heat generator except possibly one or more back-up immersion heaters;

(10) 

‘back-up immersion heater’ means a Joule effect electric resistance heater that is part of a hot water storage tank and generates heat only when the external heat source is disrupted (including during maintenance periods) or out of order, or that is part of a solar hot water storage tank and provides heat when the solar heat source is not sufficient to satisfy required comfort levels;

(11) 

‘solar device’ means a solar-only system, a solar collector, a solar hot water storage tank or a pump in the collector loop, which are placed on the market separately;

(12) 

‘solar-only system’ means a device that is equipped with one or more solar collectors and solar hot water storage tanks and possibly pumps in the collector loop and other parts, which is placed on the market as one unit and is not equipped with any heat generator except possibly one or more back-up immersion heaters;

(13) 

‘package of water heater and solar device’ means a package offered to the end-user containing one or more water heaters and one or more solar devices;

(14) 

‘water heating energy efficiency’ (ηwh ) means the ratio between the useful energy provided by a water heater or a package of water heater and solar device and the energy required for its generation, expressed in %;

(15) 

‘sound power level’ (LWA ) means the A-weighted sound power level, indoors and/or outdoors, expressed in dB;

(16) 

‘standing loss’ (S) means the heating power dissipated from a hot water storage tank at given water and ambient temperatures, expressed in W;

(17) 

‘heat pump water heater’ means a water heater that uses ambient heat from an air source, water source or ground source, and/or waste heat for heat generation.

For the purposes of Annexes II to IX, additional definitions are set out in Annex I.

Article 3

Responsibilities of suppliers and timetable

1.  

From 26 September 2015 suppliers placing water heaters on the market and/or putting them into service, including those integrated in packages of water heater and solar device, shall ensure that:

(a) 

a printed label complying with the format and content of information set out in point 1.1 of Annex III is provided for each water heater conforming to the water heating energy efficiency classes set out in point 1 of Annex II, whereby: for heat pump water heaters, the printed label is provided at least in the packaging of the heat generator; for water heaters intended for use in packages of water heater and solar device, a second label complying with the format and content of information set out in point 3 of Annex III is provided for each water heater;

(b) 

a product fiche, as set out in point 1 of Annex IV, is provided for each water heater, whereby: for heat pump water heaters, the product fiche is provided at least for the heat generator; for water heaters intended for use in packages of water heater and solar device, a second fiche, as set out in point 4 of Annex IV, is provided;

(c) 

the technical documentation, as set out in point 1 of Annex V, is provided on request to the authorities of the Member States and to the Commission;

(d) 

any advertisement relating to a specific water heater model and containing energy-related or price information includes a reference to the water heating energy efficiency class under average climate conditions for that model;

(e) 

any technical promotional material concerning a specific water heater model and describing its specific technical parameters includes a reference to the water heating energy efficiency class under average climate conditions for that model;

▼M1

(f) 

an electronic label in the format and containing the information set out in point 1.1 of Annex III is made available to dealers for each water heater model conforming to the water heating energy efficiency classes set out in point 1 of Annex II;

(g) 

an electronic product fiche as set out in point 1 of Annex IV is made available to dealers for each water heater model, whereby for heat pump water heaters models, the electronic product fiche is made available to dealers at least for the heat generator.

▼B

From 26 September 2017 a printed label complying with the format and content of information set out in point 1.2 of Annex III shall be provided for each water heater conforming to the water heating energy efficiency classes set out in point 1 of Annex II, whereby: for heat pump water heaters, the printed label shall be provided at least in the packaging of the heat generator.

▼M1

From 26 September 2017 an electronic label in the format and containing the information set out in point 1.2 of Annex III shall be made available to dealers for each water heater model conforming to the water heating energy efficiency classes set out in point 1 of Annex II.

▼B

2.  

From 26 September 2015 suppliers placing hot water storage tanks on the market and/or putting them into service shall ensure that:

(a) 

a printed label complying with the format and content of information set out in point 2.1 of Annex III is provided for each hot water storage tank conforming to the energy efficiency classes set out in point 2 of Annex II;

(b) 

a product fiche, as set out in point 2 of Annex IV, is provided;

(c) 

the technical documentation, as set out in point 2 of Annex V, is provided on request to the authorities of the Member States and to the Commission;

(d) 

any advertisement relating to a specific hot water storage tank model and containing energy-related or price information includes a reference to the energy efficiency class for that model;

(e) 

any technical promotional material concerning a specific hot water storage tank model and describing its specific technical parameters includes a reference to the energy efficiency class for that model;

▼M1

(f) 

an electronic label in the format and containing the information set out in point 2.1 of Annex III is made available to dealers for each hot water storage tank model in accordance with the energy efficiency classes set out in point 2 of Annex II;

(g) 

an electronic product fiche as set out in point 2 of Annex IV is made available to dealers for each hot water storage tank model.

▼B

From 26 September 2017 a printed label complying with the format and content of information as set out in point 2.2 of Annex III shall be provided for each hot water storage tank conforming to the energy efficiency classes set out in point 2 of Annex II.

▼M1

From 26 September 2017 an electronic label in the format and containing the information set out in point 2.2 of Annex III shall be made available to dealers for each hot water storage tank model, in accordance with the energy efficiency classes set out in point 2 of Annex II.

▼B

3.  

From 26 September 2015 suppliers placing solar devices on the market and/or putting them into service shall ensure that:

(a) 

a product fiche, as set out in point 3 of Annex IV, is provided;

(b) 

the technical documentation, as set out in point 3 of Annex V, is provided on request to the authorities of the Member States and to the Commission;

▼M1

(c) 

an electronic product fiche, as set out in point 3 of Annex IV, is made available to dealers for each solar device model.

▼B

4.  

From 26 September 2015 suppliers placing packages of water heater and solar device on the market and/or putting them into service shall ensure that:

(a) 

a printed label complying with the format and content of information set out in point 3 of Annex III is provided for each package of water heater and solar device conforming to the water heating energy efficiency classes set out in point 1 of Annex II;

(b) 

a product fiche, as set out in point 4 of Annex IV, is provided for each package of water heater and solar device;

(c) 

the technical documentation, as set out in point 4 of Annex V, is provided on request to the authorities of the Member States and to the Commission;

(d) 

any advertisement relating to a specific package of water heater and solar device model and containing energy-related or price information includes a reference to the water heating energy efficiency class under average climate conditions for that model;

(e) 

any technical promotional material concerning a specific package of water heater and solar device model and describing its specific technical parameters includes a reference to the water heating energy efficiency class under average climate conditions for that model;

▼M1

(f) 

an electronic label in the format and containing the information set out in point 3 of Annex III is made available to dealers for each model comprising a package of water heater and solar device, in accordance with the water heating energy efficiency classes set out in point 1 of Annex II;

(g) 

an electronic product fiche as set out in point 4 of Annex IV is made available to dealers for each model comprising a package of water heater and solar device.

▼B

Article 4

Responsibilities of dealers

1.  

Dealers of water heaters shall ensure that:

(a) 

each water heater, at the point of sale, bears the label provided by suppliers in accordance with Article 3(1), as set out in point 1 of Annex III, on the outside of the front of the appliance, in such a way as to be clearly visible;

▼M1

(b) 

water heaters offered for sale, hire or hire-purchase, where the end-user cannot be expected to see the water heater displayed, are marketed with the information provided by the suppliers in accordance with point 1 of Annex VI, except where the offer is made through the internet, in which case the provisions in Annex X shall apply;

▼B

(c) 

any advertisement relating to a specific water heater model and containing energy-related or price information includes a reference to the water heating energy efficiency class under average climate conditions for that model;

(d) 

any technical promotional material concerning a specific water heater model and describing its specific technical parameters includes a reference to the water heating energy efficiency class under average climate conditions for that model.

2.  

Dealers of hot water storage tanks shall ensure that:

(a) 

each hot water storage tank, at the point of sale, bears the label provided by suppliers in accordance with Article 3(2), as set out in point 2 of Annex III, on the outside of the front of the appliance, in such a way as to be clearly visible;

▼M1

(b) 

hot water storage tanks offered for sale, hire or hire-purchase, where the end user cannot be expected to see the hot water storage tank displayed, are marketed with the information provided by the suppliers in accordance with point 2 of Annex VI; except where the offer is made through the internet in which case the provisions in Annex X shall apply;

▼B

(c) 

any advertisement relating to a specific hot water storage tank model and containing energy-related or price information includes a reference to the energy efficiency class for that model;

(d) 

any technical promotional material concerning a specific hot water storage tank model and describing its specific technical parameters includes a reference to the energy efficiency class for that model.

3.  

Dealers of packages of water heater and solar device shall ensure, based on the label and fiches provided by suppliers in accordance with Article 3(1), (3) and (4), that:

(a) 

any offer for a specific package includes the water heating energy efficiency and the water heating energy efficiency class for that package under average, colder or warmer climate conditions, as applicable, by displaying with the package the label set out in point 3 of Annex III and providing the fiche set out in point 4 of Annex IV, duly filled in according to the characteristics of that package;

▼M1

(b) 

packages of water heater and solar device offered for sale, hire or hire purchase, where the end-user cannot be expected to see the package of water heater and solar device displayed, are marketed with the information provided in accordance with point 3 of Annex VI, except where the offer is made through the internet, in which case the provisions in Annex X shall apply;

▼B

(c) 

any advertisement relating to a specific package of water heater and solar device model and containing energy-related or price information includes a reference to the water heating energy efficiency class under average climate conditions for that model;

(d) 

any technical promotional material concerning a specific package of water heater and solar device model and describing its specific technical parameters includes a reference to the water heating energy efficiency class under average climate conditions for that model.

Article 5

Measurement and calculation methods

The information to be provided pursuant to Articles 3 and 4 shall be obtained by reliable, accurate and reproducible measurement and calculation methods which take into account the recognised state-of-the-art measurement and calculation methods, as set out in Annex VII and Annex VIII.

Article 6

Verification procedure for market surveillance purposes

Member States shall apply the procedure set out in Annex IX when assessing the conformity of the declared water heating energy efficiency class, water heating energy efficiency, annual energy consumption and sound power level of water heaters and the declared energy efficiency class and standing loss of hot water storage tanks.

Article 7

Review

The Commission shall review this Regulation in the light of technological progress no later than five years after its entry into force. The review shall in particular assess any significant changes in the market shares of various types of appliances and the appropriateness of the package fiche and label set out in point 3 of Annex III and point 4 of Annex IV.

Article 8

Entry into force and application

This Regulation shall enter into force on the twentieth day following that of its publication in the Official Journal of the European Union.

This Regulation shall be binding in its entirety and directly applicable in all Member States.




ANNEX I

Definitions applicable for Annexes II to IX

For the purposes of Annexes II to IX, the following definitions shall apply:

(1) 

‘conventional water heater’ means a water heater that generates heat using the combustion of fossil and/or biomass fuels and/or the Joule effect in electric resistance heating elements;

(2) 

‘solar water heater’ means a water heater equipped with one or more solar collectors, solar hot water storage tanks, heat generators and possibly pumps in the collector loop and other parts, a solar water heater is placed on the market as one unit;

(3) 

‘load profile’ means a given sequence of water draw-offs, as specified in Annex VII, Table 3; each water heater meets at least one load profile;

(4) 

‘water draw-off’ means a given combination of useful water flow rate, useful water temperature, useful energy content and peak temperature, as specified in Annex VII, Table 3;

(5) 

‘useful water flow rate’ (f) means the minimum flow rate, expressed in litres per minute, for which hot water is contributing to the reference energy, as specified in Annex VII, Table 3;

(6) 

‘useful water temperature’ (Tm ) means the water temperature, expressed in degrees Celsius, at which hot water starts contributing to the reference energy, as specified in Annex VII, Table 3;

(7) 

‘useful energy content’ (Qtap ) means the energy content of hot water, expressed in kWh, provided at a temperature equal to, or above, the useful water temperature, and at water flow rates equal to, or above, the useful water flow rate, as specified in Annex VII, Table 3;

(8) 

‘energy content of hot water’ means the product of the specific heat capacity of water, the average temperature difference between the hot water output and cold water input, and the total mass of the hot water delivered;

(9) 

‘peak temperature’ (Tp ) means the minimum water temperature, expressed in degrees Celsius, to be achieved during water draw-off, as specified in Annex VII, Table 3;

(10) 

‘reference energy’ (Qref ) means the sum of the useful energy content of water draw-offs, expressed in kWh, in a particular load profile, as specified in Annex VII, Table 3;

(11) 

‘maximum load profile’ means the load profile with the greatest reference energy that a water heater is able to provide while fulfilling the temperature and flow rate conditions of that load profile;

(12) 

‘declared load profile’ means the load profile applied when determining water heating energy efficiency;

(13) 

‘conversion coefficient’ (CC) means a coefficient reflecting the estimated 40 % average EU generation efficiency referred to in Directive 2012/27/EU of the European Parliament and of the Council ( 3 ); the value of the conversion coefficient is CC = 2,5;

(14) 

‘daily electricity consumption’ (Qelec ) means the consumption of electricity over 24 consecutive hours under the declared load profile and under given climate conditions, expressed in kWh in terms of final energy;

(15) 

‘daily fuel consumption’(Qfuel) means the consumption of fuels over 24 consecutive hours under the declared load profile and under given climate conditions, expressed in kWh in terms of GCV, and for the purposes of point 4 in Annex VIII expressed in GJ in terms of GCV;

(16) 

‘gross calorific value’ (GCV) means the total amount of heat released by a unit quantity of fuel when it is burned completely with oxygen and when the products of combustion are returned to ambient temperature; this quantity includes the condensation heat of any water vapour contained in the fuel and of the water vapour formed by the combustion of any hydrogen contained in the fuel;

(17) 

‘smart control’ means a device that automatically adapts the water heating process to individual usage conditions with the aim of reducing energy consumption;

(18) 

‘smart control compliance’ (smart) means the measure of whether a water heater equipped with smart controls fulfils the criterion set out in point 5 of Annex VIII;

(19) 

‘smart control factor’ (SCF) means the water heating energy efficiency gain due to smart control under the conditions set out in point 3 of Annex VII;

(20) 

‘weekly electricity consumption with smart controls’ (Qelec,week,smart ) means the weekly electricity consumption of a water heater with the smart control function enabled, expressed in kWh in terms of final energy;

(21) 

‘weekly fuel consumption with smart controls’ (Qfuel,week,smart ) means the weekly fuel consumption of a water heater with the smart control function enabled, expressed in kWh in terms of GCV;

(22) 

‘weekly electricity consumption without smart controls’ (Qelec,week ) means the weekly electricity consumption of a water heater with the smart control function disabled, expressed in kWh in terms of final energy;

(23) 

‘weekly fuel consumption without smart controls’ (Qfuel,week ) means the weekly fuel consumption of a water heater with the smart control function disabled, expressed in kWh in terms of GCV;

(24) 

‘annual electricity consumption’ (AEC) means the annual electricity consumption of a water heater under the declared load profile and under given climate conditions, expressed in kWh in terms of final energy;

(25) 

‘annual fuel consumption’ (AFC) means the annual fossil and/or biomass fuel consumption of a water heater under the declared load profile and under given climate conditions, expressed in GJ in terms of GCV;

(26) 

‘ambient correction term’ (Qcor ) means a term which takes into account the fact that the place where the water heater is installed is not an isothermal place, expressed in kWh;

(27) 

‘standby heat loss’ (Pstby ) means the heat loss of a heat pump water heater in operating modes without heat demand, expressed in kW;

(28) 

‘average climate conditions’, ‘colder climate conditions’ and ‘warmer climate conditions’ mean the temperatures and global solar irradiance conditions characteristic for the cities of Strasbourg, Helsinki and Athens, respectively;

(29) 

‘annual energy consumption’ (Qtota ) means the annual energy consumption of a solar water heater, expressed in kWh in terms of primary energy and/or kWh in terms of GCV;

(30) 

‘annual non-solar heat contribution’ (Qnonsol ), means the annual contribution of electricity (expressed in kWh in terms of primary energy) and/or fuels (expressed in kWh in terms of GCV) to the useful heat output of a solar water heater or a package of water heater and solar device, taking into account the annual amount of heat captured by the solar collector and the heat losses of the solar hot water storage tank;

(31) 

‘solar collector’ means a device designed to absorb global solar irradiance and to transfer the heat energy so produced to a fluid passing through it; it is characterised by the collector aperture area, the zero-loss efficiency, the first order coefficient, the second-order coefficient and the incidence angle modifier;

(32) 

‘global solar irradiance’ means the rate of total incoming solar energy, both direct and diffuse, on a collector plane with an inclination of 45 degrees and southward orientation at the Earth’s surface, expressed in W/m2;

(33) 

‘collector aperture area’ (Asol ) means the maximum projected area through which unconcentrated solar radiation enters the collector, expressed in m2;

(34) 

‘zero-loss efficiency’ (η0 ) means the efficiency of the solar collector, when the solar collector mean fluid temperature is equal to the ambient temperature;

(35) 

‘first-order coefficient’ (a1 ) means the heat loss coefficient of a solar collector, expressed in W/(m2 K);

(36) 

‘second-order coefficient’ (a2 ) means the coefficient measuring the temperature dependence of the first order coefficient, expressed in W/(m2 K2);

(37) 

‘incidence angle modifier’ (IAM) means the ratio of the useful heat output of the solar collector at a given incidence angle and its useful heat output at an incidence angle of 0 degrees;

(38) 

‘incidence angle’ means the angle between the direction to the sun and the direction perpendicular to the solar collector aperture;

(39) 

‘solar hot water storage tank’ means a hot water storage tank storing heat energy produced by one or more solar collectors;

(40) 

‘heat generator water heating energy efficiency’ (ηwh,nonsol ) means the water heating energy efficiency of a heat generator which is part of a solar water heater, expressed in %, established under average climate conditions and without using solar heat input;

(41) 

‘auxiliary electricity consumption’ (Qaux ), for the purpose of Figure 1 in Annex IV referred to as ‘auxiliary electricity’, means the annual electricity consumption of a solar water heater or a solar-only system that is due to the pump power consumption and the standby power consumption, expressed in kWh in terms of final energy;

(42) 

‘pump power consumption’ (solpump) means the rated electrical power consumption of the pump in the collector loop of a solar water heater or solar-only system, expressed in W;

(43) 

‘standby power consumption’ (solstandby) means the rated electrical power consumption of a solar water heater or solar-only system when the pump and the heat generator are inactive, expressed in W;

(44) 

‘model identifier’ means the code, usually alphanumeric, which distinguishes a specific water heater, hot water storage tank, solar device or package of water heater and solar device model from other models with the same trade mark, supplier’s name or dealer’s name.




ANNEX II

Energy efficiency classes

1.   WATER HEATING ENERGY EFFICIENCY CLASSES OF WATER HEATERS

The water heating energy efficiency class of a water heater shall be determined on the basis of its water heating energy efficiency as set out in Table 1.

The water heating energy efficiency of a water heater shall be calculated in accordance with point 3 of Annex VIII, for solar water heaters and heat pump water heaters under average climate conditions.



Table 1

Water heating energy efficiency classes of water heaters, categorised by declared load profiles, ηwh in %

 

3XS

XXS

XS

S

M

L

XL

XXL

A+++

ηwh ≥ 62

ηwh ≥ 62

ηwh ≥ 69

ηwh ≥ 90

ηwh ≥ 163

ηwh ≥ 188

ηwh ≥ 200

ηwh ≥ 213

A++

53 ≤ ηwh < 62

53 ≤ ηwh < 62

61 ≤ ηwh < 69

72 ≤ ηwh < 90

130 ≤ ηwh < 163

150 ≤ ηwh < 188

160 ≤ ηwh < 200

170 ≤ ηwh < 213

A+

44 ≤ ηwh < 53

44 ≤ ηwh < 53

53 ≤ ηwh < 61

55 ≤ ηwh < 72

100 ≤ ηwh < 130

115 ≤ ηwh < 150

123 ≤ ηwh < 160

131 ≤ ηwh < 170

A

35 ≤ ηwh < 44

35 ≤ ηwh < 44

38 ≤ ηwh < 53

38 ≤ ηwh < 55

65 ≤ ηwh < 100

75 ≤ ηwh < 115

80 ≤ ηwh < 123

85 ≤ ηwh < 131

B

32 ≤ ηwh < 35

32 ≤ ηwh < 35

35 ≤ ηwh < 38

35 ≤ ηwh < 38

39 ≤ ηwh < 65

50 ≤ ηwh < 75

55 ≤ ηwh < 80

60 ≤ ηwh < 85

C

29 ≤ ηwh < 32

29 ≤ ηwh < 32

32 ≤ ηwh < 35

32 ≤ ηwh < 35

36 ≤ ηwh < 39

37 ≤ ηwh < 50

38 ≤ ηwh < 55

40 ≤ ηwh < 60

D

26 ≤ ηwh < 29

26 ≤ ηwh < 29

29 ≤ ηwh < 32

29 ≤ ηwh < 32

33 ≤ ηwh < 36

34 ≤ ηwh < 37

35 ≤ ηwh < 38

36 ≤ ηwh < 40

E

22 ≤ ηwh < 26

23 ≤ ηwh < 26

26 ≤ ηwh < 29

26 ≤ ηwh < 29

30 ≤ ηwh < 33

30 ≤ ηwh < 34

30 ≤ ηwh < 35

32 ≤ ηwh < 36

F

19 ≤ ηwh < 22

20 ≤ ηwh < 23

23 ≤ ηwh < 26

23 ≤ ηwh < 26

27 ≤ ηwh < 30

27 ≤ ηwh < 30

27 ≤ ηwh < 30

28 ≤ ηwh < 32

G

ηwh < 19

ηwh < 20

ηwh < 23

ηwh < 23

ηwh < 27

ηwh < 27

ηwh < 27

ηwh < 28

2.   ENERGY EFFICIENCY CLASSES OF HOT WATER STORAGE TANKS

The energy efficiency class of a hot water storage tank shall be determined on the basis of its standing loss as set out in Table 2.



Table 2

Energy efficiency classes of hot water storage tanks

Energy efficiency class

Standing loss S in Watts, with storage volume V in litres

A+

image

A

image

B

image

C

image

D

image

E

image

F

image

G

image




ANNEX III

The labels

1.   WATER HEATERS

1.1.    Label 1

1.1.1.    Conventional water heaters in water heating energy efficiency classes A to G

image
(a) 

The following information shall be included in the label:

I. 

supplier’s name or trade mark;

II. 

supplier’s model identifier;

III. 

the water heating function, including the declared load profile expressed as the appropriate letter in accordance with Table 3 of Annex VII;

IV. 

the water heating energy efficiency class, determined in accordance with point 1 of Annex II; the head of the arrow containing the water heating energy efficiency class of the water heater shall be placed at the same height as the head of the relevant energy efficiency class;

V. 

the annual electricity consumption in kWh in terms of final energy and/or the annual fuel consumption in GJ in terms of GCV, rounded to the nearest integer and calculated in accordance with point 4 of Annex VIII;

VI. 

the sound power level LWA , indoors, in dB, rounded to the nearest integer;

VII. 

for conventional water heaters able to work only during off-peak hours, the pictogram referred to in point 4(d)(10) of this Annex may be added.

(b) 

The design aspects of the label for conventional water heaters shall be in accordance with point 4 of this Annex.

1.1.2.    Solar water heaters in water heating energy efficiency classes A to G

image
(a) 

The following information shall be included in the label:

I. 

supplier’s name or trade mark;

II. 

supplier’s model identifier;

III. 

the water heating function, including the declared load profile expressed as the appropriate letter in accordance with Table 3 of Annex VII;

IV. 

the water heating energy efficiency class under average climate conditions, determined in accordance with point 1 of Annex II; the head of the arrow containing the water heating energy efficiency class of the water heater shall be placed at the same height as the head of the relevant energy efficiency class;

V. 

the annual electricity consumption in kWh in terms of final energy or the annual fuel consumption in GJ in terms of GCV, under average, colder and warmer climate conditions, rounded to the nearest integer and calculated in accordance with point 4 of Annex VIII;

VI. 

European solar map displaying three indicative global solar irradiance zones;

VII. 

the sound power level LWA , indoors, in dB, rounded to the nearest integer.

(b) 

The design aspects of the label for solar water heaters shall be in accordance with point 5 of this Annex.

1.1.3.    Heat pump water heaters in water heating energy efficiency classes A to G

image
(a) 

The following information shall be included in the label:

I. 

supplier’s name or trade mark;

II. 

supplier’s model identifier;

III. 

the water heating function, including the declared load profile expressed as the appropriate letter in accordance with Table 3 of Annex VII;

IV. 

the water heating energy efficiency class under average climate conditions, determined in accordance with point 1 of Annex II; the head of the arrow containing the water heating energy efficiency class of the water heater shall be placed at the same height as the head of the relevant energy efficiency class;

V. 

the annual electricity consumption in kWh in terms of final energy and/or the annual fuel consumption in GJ in terms of GCV, under average, colder and warmer climate conditions, rounded to the nearest integer and calculated in accordance with point 4 of Annex VIII;

VI. 

European temperature map displaying three indicative temperature zones;

VII. 

the sound power level LWA , indoors (if applicable) and outdoors, in dB, rounded to the nearest integer;

VIII. 

for heat pump water heaters able to work only during off-peak hours, the pictogram referred to in point 6(d)(11) of this Annex may be added.

(b) 

The design aspects of the label for heat pump water heaters shall be in accordance with point 6 of this Annex. By way of exception, where a model has been granted an ‘EU Ecolabel’ under Regulation (EC) No 66/2010 of the European Parliament and of the Council ( 4 ), a copy of the EU Ecolabel may be added.

1.2.    Label 2

1.2.1.    Conventional water heaters in water heating energy efficiency classes A+ to F

image
(a) 

The information listed in point 1.1.1(a) of this Annex shall be included in the label.

(b) 

The design aspects of the label for conventional water heaters shall be in accordance with point 4 of this Annex.

1.2.2.    Solar water heaters in water heating energy efficiency classes A+ to F

image
(a) 

The information listed in point 1.1.2(a) of this Annex shall be included in the label.

(b) 

The design aspects of the label for solar water heaters shall be in accordance with point 5 of this Annex.

1.2.3.    Heat pump water heaters in water heating energy efficiency classes A+ to F

image
(a) 

The information listed in point 1.1.3(a) of this Annex shall be included in the label.

(b) 

The design aspects of the label for heat pump water heaters shall be in accordance with point 6 of this Annex.

2.   HOT WATER STORAGE TANKS

2.1.    Label 1 for hot water storage tanks in energy efficiency classes A to G

image
(a) 

The following information shall be included in the label:

I. 

supplier’s name or trade mark;

II. 

supplier’s model identifier;

III. 

the water storage function;

IV. 

the energy efficiency class, determined in accordance with point 2 of Annex II; the head of the arrow containing the energy efficiency class of the hot water storage tank shall be placed at the same height as the head of the relevant energy efficiency class;

V. 

the standing loss in W, rounded to the nearest integer;

VI. 

the hot water storage tank volume in litres, rounded to the nearest integer.

(b) 

The design aspects of the label for hot water storage tanks shall be in accordance with point 7 of this Annex.

2.2.    Label 2 for hot water storage tanks in energy efficiency classes A+ to F

image
(a) 

The information listed in point 2.1(a) of this Annex shall be included in the label.

(b) 

The design aspects of the label for hot water storage tanks shall be in accordance with point 7 of this Annex.

3.   PACKAGES OF WATER HEATER AND SOLAR DEVICE

Label for packages of water heater and solar device in water heating energy efficiency classes A+++ to G