19.7.2016   

EN

Official Journal of the European Union

L 193/117


Corrigendum to Commission Directive (EU) 2016/844 of 27 May 2016 amending Directive 2009/45/EC of the European Parliament and of the Council on safety rules and standards for passenger ships

( Official Journal of the European Union L 141 of 28 May 2016 )

On page 55, in Table 5.1(a) in paragraph (2), subparagraph (h) of the Annex, concerning the Annex to Directive 2009/45/EC:

for:

‘Table 5.1(a)

Fire integrity of bulkheads separating adjacent spaces

Spaces

 

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

(11)

Control stations

(1)

A-0e

A-0

60

A-0

A-15

A-60

A-15

A-60

A-60

*

A-60

Corridors

(2)

 

Ce

B-0e

A-0e

B-0e

B-0e

A-60

A-15

A-60

A-15

A-0d

*

A-30

Accommodation spaces

(3)

 

 

Ce

A-0e

B-0e

B-0e

A-60

A-0

A-0

A-15

A-0d

*

A-30

A-0d

Stairways

(4)

 

 

 

A-0e

B-0e

A-0e

B-0e

A-60

A-0

A-0

A-15

A-0d

*

A-30

Service spaces (low risk)

(5)

 

 

 

 

Ce

A-60

A-0

A-0

A-0

*

A-0

Machinery spaces of category A

(6)

 

 

 

 

 

*

A-0

A-0

A-60

*

A-60

Other machinery spaces

(7)

 

 

 

 

 

 

A-0b

A-0

A-0

*

A-0

Cargo spaces

(8)

 

 

 

 

 

 

 

*

A-0

*

A-0

Service spaces (high risk)

(9)

 

 

 

 

 

 

 

 

A-0b

*

A-30

Open decks

(10)

 

 

 

 

 

 

 

 

 

 

A-0

Special category and Ro-Ro spaces

(11)

 

 

 

 

 

 

 

 

 

 

A-30’

read:

‘Table 5.1(a)

Fire integrity of bulkheads separating adjacent spaces

Spaces

 

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

(11)

Control stations

(1)

A-0c

A-0

A-60

A-0

A-15

A-60

A-15

A-60

A-60

*

A-60

Corridors

(2)

 

Ce

B-0e

A-0a

B-0e

B-0e

A-60

A-0

A-0

A-15

A-0d

*

A-30

Accommodation spaces

(3)

 

 

Ce

A-0a

B-0e

B-0e

A-60

A-0

A-0

A-15

A-0d

*

A-30

A-0d

Stairways

(4)

 

 

 

A-0a

B-0e

A-0a

B-0e

A-60

A-0

A-0

A-15

A-0d

*

A-30

Service spaces (low risk)

(5)

 

 

 

 

Ce

A-60

A-0

A-0

A-0

*

A-0

Machinery spaces of category A

(6)

 

 

 

 

 

*

A-0

A-0

A-60

*

A-60

Other machinery spaces

(7)

 

 

 

 

 

 

A-0b

A-0

A-0

*

A-0

Cargo spaces

(8)

 

 

 

 

 

 

 

*

A-0

*

A-0

Service spaces (high risk)

(9)

 

 

 

 

 

 

 

 

A-0b

*

A-30

Open decks

(10)

 

 

 

 

 

 

 

 

 

 

A-0

Special category spaces

(11)

 

 

 

 

 

 

 

 

 

 

A-30’

on page 56, in Table 5.2(a) in paragraph (2), subparagraph (i) of the Annex, concerning the Annex to Directive 2009/45/EC:

for:

‘Table 5.2(a)

Fire integrity of decks separating adjacent spaces

Spaces Below↓

Spaces → Above

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

(11)

Control stations

(1)

A-0

A-0

A-0

A-0

A-0

A-60

A-0

A-0

A-0

*

A-60

Corridors

(2)

A-0

*

*

A-0

*

A-60

A-0

A-0

A-0

*

A-30

Accommodation spaces

(3)

A-60

A-0

*

A-0

*

A-60

A-0

A-0

A-0

*

A-30

A-0d

Stairways

(4)

A-0

A-0

A-0

*

A-0

A-60

A-0

A-0

A-0

*

A-30

Service spaces (low risk)

(5)

A-15

A-0

A-0

A-0

*

A-60

A-0

A-0

A-0

*

A-0

Machinery spaces of category A

(6)

A-60

A-60

A-60

A-60

A-60

*

A-60f

A-30

A-60

*

A-60

Other machinery spaces

(7)

A-15

A-0

A-0

A-0

A-0

A-0

*

A-0

A-0

*

A-0

Cargo spaces

(8)

A-60

A-0

A-0

A-0

A-0

A-0

A-0

*

A-0

*

A-0

Service spaces (high risk)

(9)

A-60

A-30

A-0d

A-30

A-0d

A-30

A-0d

A-0

A-60

A-0

A-0

A-0

*

A-30

Open decks

(10)

*

*

*

*

*

*

*

*

*

A-0

Special category and Ro-Ro spaces

(11)

A-60

A-30

A-30

A-0d

A-30

A-0

A-60

A-0

A-0

A-30

A-0

A-30’

read:

‘Table 5.2(a)

Fire integrity of decks separating adjacent spaces

Space BelowSpace Above

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

(11)

Control stations

(1)

A-0

A-0

A-0

A-0

A-0

A-60

A-0

A-0

A-0

*

A-60

Corridors

(2)

A-0

*

*

A-0

*

A-60

A-0

A-0

A-0

*

A-30

Accommodation spaces

(3)

A-60

A-0

*

A-0

*

A-60

A-0

A-0

A-0

*

A-30

A-0d

Stairways

(4)

A-0

A-0

A-0

*

A-0

A-60

A-0

A-0

A-0

*

A-30

Service spaces (low risk)

(5)

A-15

A-0

A-0

A-0

*

A-60

A-0

A-0

A-0

*

A-0

Machinery spaces of category A

(6)

A-60

A-60

A-60

A-60

A-60

*

A-60f

A-30

A-60

*

A-60

Other machinery spaces

(7)

A-15

A-0

A-0

A-0

A-0

A-0

*

A-0

A-0

*

A-0

Cargo spaces

(8)

A-60

A-0

A-0

A-0

A-0

A-0

A-0

*

A-0

*

A-0

Service spaces (high risk)

(9)

A-60

A-30

A-0d

A-30

A-0d

A-30

A-0d

A-0

A-60

A-0

A-0

A-0

*

A-30

Open decks

(10)

*

*

*

*

*

*

*

*

*

A-0

Special category spaces

(11)

A-60

A-30

A-30

A-0d

A-30

A-0

A-60

A-0

A-0

A-30

A-0

A-30’

on page 61, in paragraph (2)(l) of the Annex, concerning point 7 of the rule 9a in Annex I to Directive 2009/45/EC:

for:

‘.7   Ventilation systems for laundries in passenger ships carrying more than 36 passengers

Exhaust ducts from laundries and drying rooms of category (13) spaces as defined in Regulation II-2/B//.2.2 shall be fitted with:’,

read:

‘.7   Ventilation systems for laundries in passenger ships carrying more than 36 passengers

Exhaust ducts from laundries and drying rooms of category (13) spaces as defined in Regulation II-2/B/4.2.2 shall be fitted with:’.