Commission communication in the framework of the implementation of: Commission Regulation (EC) No 244/2009 of 18 March 2009 implementing Directive 2005/32/EC of the European Parliament and of the Council with regard to ecodesign requirements for non-directional household lamps, amended by Commission Regulation (EC) No 859/2009 of 18 September 2009 as regards the ecodesign requirements on ultraviolet radiation of non-directional household lamps and Commission Delegated Regulation (EU) No 874/2012 of 12 July 2012 supplementing Directive 2010/30/EU of the European Parliament and of the Council with regard to energy labelling of electrical lamps and luminaires and Commission Regulation (EU) No 1194/2012 of 12 December 2012 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for directional lamps, light emitting diode lamps and related equipment (Publication of titles and references of transitional methods of measurement for the implementation of Commission Regulation (EC) No 244/2009 amended by Commission Regulation (EC) No 859/2009, Commission Delegated Regulation (EU) No 874/2012, and Commission Regulation (EU) No 1194/2012) Text with EEA relevance

OJ C 22, 24.1.2014, p. 17–31 (BG, ES, CS, DA, DE, ET, EL, EN, FR, HR, IT, LV, LT, HU, MT, NL, PL, PT, RO, SK, SL, FI, SV)

24.1.2014   

EN

Official Journal of the European Union

C 22/17


Commission communication in the framework of the implementation of:

Commission Regulation (EC) No 244/2009 of 18 March 2009 implementing Directive 2005/32/EC of the European Parliament and of the Council with regard to ecodesign requirements for non-directional household lamps, amended by Commission Regulation (EC) No 859/2009 of 18 September 2009 as regards the ecodesign requirements on ultraviolet radiation of non-directional household lamps

and

Commission Delegated Regulation (EU) No 874/2012 of 12 July 2012 supplementing Directive 2010/30/EU of the European Parliament and of the Council with regard to energy labelling of electrical lamps and luminaires

and

Commission Regulation (EU) No 1194/2012 of 12 December 2012 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for directional lamps, light emitting diode lamps and related equipment

(Publication of titles and references of transitional methods of measurement  (1) for the implementation of Commission Regulation (EC) No 244/2009 amended by Commission Regulation (EC) No 859/2009, Commission Delegated Regulation (EU) No 874/2012, and Commission Regulation (EU) No 1194/2012)

(Text with EEA relevance)

2014/C 22/02

For the purposes of verification of compliance with the requirements of Commission Regulation (EC) No 244/2009 amended by Commission Regulation (EC) No 859/2009, Commission Delegated Regulation (EU) No 874/2012, and Commission Regulation (EU) No 1194/2012 the following measurement procedures shall be used if:

no other measurement procedures are specified in harmonised standards of which the reference numbers have been published for that purpose in the Official Journal of the European Union, (particularly, most of the mentioned EN standards are also ISO standards)

or no other specific measurement procedures for verification of compliance are referenced in the afore mentioned Regulations.

The definitions of 'directional lamps' and 'non-directional lamps' in Article 2 of Commission Regulation (EU) No 1194/2012 shall apply.

1.

In case no specific documents have been referenced for measured parameters, reliable, accurate and reproducible measurement procedures, which take into account generally recognised state-of-the-art measurement methods, shall be used. This includes but is not limited to the number of switching cycles, the rated lifetime for LEDs, and the premature failure rate of LEDs.

2.

Photometric parameters shall be measured according to prEN 13032-4 for LED lamps and modules (including colourimetric parameters), and EN 13032-1 for all other types.

3.

For non-directional lamps tests shall be carried out as follows:

a.

Incandescent light bulbs shall be measured according to methods set out in the following documents:

Non-directional incandescent light bulbs

Measured parameter

Reference

Remarks

EEI

EN 60064, 3.4.1 and Annex A for power;

CIE 84 for basics of luminous flux measurement;

EN60064, 3.4.2 for luminous flux

The average EEI value shall be calculated from the arithmetic mean of each product's individual EEI.

Lamp caps

EN 60064 in conjunction with EN 60061-1

 

Lamp survival factor

CIE 97

 

Rated lifetime, lamp lifetime

EN 60064, Annex A and B

 

Lumen maintenance, lamp lumen maintenance factor

EN 60064, 3.5 and Annex A

 

Number of switching cycles

Reliable, accurate and reproducible measurement procedures shall be used.

Starting time

Not relevant for incandescent lamps.

Lamp warm-up time

Not relevant for incandescent lamps.

Premature failure rate

EN 60064, 3.5

 

Lamp power factor

Not relevant for incandescent lamps (power factor equals 1).

Chromaticity coordinates

CIE S 010 (= ISO 23539) for basics on photometry,

CIE 15 for basics on colorimetry,

CIE 63 for spectroradio-metric measurement

 

CCT

CIE 15

 

CRI

Not relevant for incandescent lamps (CRI is 100).

Luminance

CIE 18.2

 

Specific effective UV radiant power

EN/CIE 62471

 

Dimensions

EN 60064

 

b.

Halogen incandescent light bulbs shall be measured according to methods set out in the following documents:

Non-directional halogen incandescent light bulbs

Measured parameter

Reference

Remarks

Lamp efficacy, luminous efficacy

EN 60357, 1.4.5 and Annex A for luminous flux;

CIE 84 for basics of luminous flux;

EN 60357, 1.4.4 for power

The average efficacy value shall be calculated from the arithmetic mean of each product's individual efficacy.

Lamp caps

EN 60432-2, 1.1 for halogen for domestic and general lighting;

EN 60432-3, 2.3 for halogen (not for vehicles);

in conjunction with EN 60061-1

 

Lamp survival factor

CIE 97

 

Rated lifetime, lamp lifetime

EN 60357, 1.4 and Annex A

 

Lumen maintenance, lamp lumen maintenance factor

EN 60357, 1.4 and Annex A

 

Number of switching cycles

Reliable, accurate and reproducible measurement procedures shall be used.

Starting time

Not relevant for halogen incandescent lamps.

Lamp warm-up time

Not relevant for halogen incandescent lamps.

Premature failure rate

EN 60357, Annex A

 

Lamp power factor (only for lamps with integrated controlgear)

EN 61000-3-2

 

Chromaticity coordinates

CIE S 010 (= ISO 23539) for basics on photometry,

CIE 15 for basics on colorimetry,

CIE 63 for spectroradio-metric measurement

 

CCT

CIE 15

 

CRI

Not relevant for halogen incandescent lamps (CRI is 100).

Luminance

CIE 18.2

 

Specific effective UV radiant power

EN/CIE 62471

 

Lamp dimensions

EN 60357

 

c.

Compact fluorescent lamps with integrated control gear shall be measured according to methods set out in the following documents:

Non-directional compact fluorescent lamps

Measured parameter

Reference

Remarks

Lamp efficacy, luminous efficacy

EN 60969, at present 34A/1701/CDV Annex A for luminous flux;

CIE 84 for basics of luminous flux;

34A/1701/CDV Annex A for power

The average efficacy value shall be calculated from the arithmetic mean of each product's individual efficacy.

Lamp caps

EN 60968 in conjunction with EN 60061-1

 

Lamp survival factor

CIE 97

 

Rated lifetime, lamp lifetime

EN 60969, at present 34A/1701/CDV Annex G

 

Lumen maintenance, lamp lumen maintenance factor

EN 60969, at present 34A/1701/CDV Annex D

 

Number of switching cycles

EN 60969, at present 34A/1701/CDV Annex F

 

Starting time

EN 60969, at present 34A/1701/CDV Annex B

 

Lamp warm-up time

EN 60969, at present 34A/1701/CDV Annex C

The run-up time shall be used instead.

Premature failure rate

EN 60969, at present 34A/1701/CDV Annex G

 

Lamp power factor (only for lamps with integrated controlgear)

EN 61000-3-2

 

Chromaticity coordinates

CIE 15

 

CCT

CIE 15

 

CRI

CIE 13.3

 

Luminance

CIE 18.2

 

Specific effective UV radiant power

EN/CIE 62471

 

Lamp dimensions

EN 60969, at present 34A/1701/CDV Table 3

 

Mercury content

Commission Decision 2002/747/EC (Annex)

 

Dimmability

Reliable, accurate and reproducible measurement procedures shall be used.

d.

Light emitting diode lamps shall be measured according to methods set out in the following documents:

Non-directional light emitting diode lamp

Measured parameter

Reference

Remarks

Lamp efficacy

EN 62612, 9.3 efficacy. To be corrected according to IM 244 with correction factor.

The average efficacy value shall be calculated from the arithmetic mean of each product's individual efficacy.

Rated lifetime, lamp lifetime

Reliable, accurate and reproducible measurement procedures shall be used. For LED lamps, EN 62612 provides procedures for 6 000 h testing time.

Lamp survival factor

EN 62612, 11.2

The compliance criteria of the regulations shall be applied.

Lumen maintenance, lamp lumen maintenance factor

EN 62612, 11.2

The compliance criteria of the regulations shall be applied.

Number of switching cycles

EN 62612, 11.3.3

 

Starting time

Reliable, accurate and reproducible measurement procedures shall be used.

Lamp warm-up time

Reliable, accurate and reproducible measurement procedures shall be used.

Premature failure rate

EN 62612, 11.2

An additional read point at 1 000 h and the compliance criteria according to the regulations shall be applied.

Lamp power factor

EN 61000-3-2

 

Chromaticity coordinates

prEN 13032-4

 

CCT

prEN 13032-4

 

CRI

prEN 13032-4

 

Luminance

CIE 18.2

 

Specific effective UV radiant power

EN/CIE 62471

 

UVA+UVB

EN/CIE 62471

 

Lamp dimensions

EN 62612, 6

 

Dimmability

EN 62560, 5.2

The presence of a symbol or warning shall be checked.

Lamp caps

EN 62560

 

e.

Light emitting diode modules shall be measured according to methods set out in the following documents:

Non-directional light emitting diode modules

Measured parameter

Reference

Remarks

Lamp efficacy, luminous efficacy

IEC 62717, at present 34A/1659/CDV, 9.3 efficacy

The average efficacy value shall be calculated from the arithmetic mean of each product's individual efficacy.

Rated lifetime, lamp lifetime

Reliable, accurate and reproducible measurement procedures shall be used. For LED lamps, EN 62612 provides procedures for 6 000 h testing time.

Lamp survival factor

IEC 62717, 10.2

The compliance criteria of the regulations shall be applied.

Lumen maintenance, lamp lumen maintenance factor

IEC 62717, 10.2

The compliance criteria of the regulations shall be applied.

Number of switching cycles

IEC 62717, at present 34A/1659/CDV, 11.3.3

 

Starting time

Reliable, accurate and reproducible measurement procedures shall be used. The method described in 34A/1701/CDV (for CFLi) may be adapted.

Lamp warm-up time

Reliable, accurate and reproducible measurement procedures shall be used. The method described in 34A/1701/CDV (for CFLi) may be adapted.

Premature failure rate

IEC 62717, 11.2

An additional read point at 1 000 h and the compliance criteria according to the regulations shall be applied.

Lamp power factor

EN 61000-3-2

 

Chromaticity coordinates

prEN 13032-4

 

CCT

prEN 13032-4

 

CRI

prEN 13032-4

 

Luminance

CIE 18.2

 

Specific effective UV radiant power

EN/CIE 62471

 

UVA+UVB

EN/CIE 62471

 

Lamp dimensions

IEC 62717, at present 34A/1659/CDV, 5

 

Dimmability

IEC 62717, at present 34A/1659/CDV, 6 and 7.2

The presence of a symbol or warning shall be checked. A list of compatible dimmers is not possible due to the arbitrary combination with controlgears.

4.

For directional lamps tests shall be carried out as follows:

a.

Incandescent light bulbs shall be measured according to methods set out in the following documents:

Directional incandescent light bulbs

Measured parameter

Reference

Remarks

EEI

CIE 84 for general conditions of luminous flux measurement.

L2(AP)005 for cone luminous flux.

EN 60064, 3.4.1 for power.

The average EEI value shall be calculated from the arithmetic mean of each product's individual EEI.

Rated lifetime

EN 60064, Annex A and B

 

Lumen maintenance

EN 60064, 3.5 and Annex A

 

Number of switching cycles

Reliable, accurate and reproducible measurement procedures shall be used.

Starting time

Not relevant for incandescent lamps.

Lamp warm-up time

Not relevant for incandescent lamps.

Premature failure rate

EN 60064, 3.5 and Annex A

 

Lamp power factor

Not relevant for incandescent lamps (power factor equals 1).

Chromaticity coordinates

CIE S 010 (= ISO 23539) for basics on photometry,

CIE 15 for basics on colorimetry,

CIE 63 for spectroradio-metric measurement

 

CRI

Not relevant for incandescent lamps (CRI is 100).

Equivalence claim for retrofit lamps

Not relevant for incandescent lamps.

Beam angle

IEC/TR 61341

 

Peak intensity

IEC/TR 61341

 

b.

Halogen incandescent light bulbs shall be measured according to methods set out in the following documents:

Directional halogen incandescent light bulbs

Measured parameter

Reference

Remarks

EEI

CIE 84 for general conditions of luminous flux measurement.

L2(AP)005 for cone luminous flux.

EN 60357, 1.4.4 for power.

The average EEI value shall be calculated from the arithmetic mean of each product's individual EEI.

Rated lifetime

EN 60357, 1.4 and Annex A

 

Lumen maintenance

EN 60357, 1.4 and Annex A

 

Number of switching cycles

Reliable, accurate and reproducible measurement procedures shall be used. EN 60357, A.3 duty cycle, may partially be used.

Starting time

Not relevant for halogen incandescent lamps.

Lamp warm-up time

Not relevant for halogen incandescent lamps.

Premature failure rate

EN 60357, Annex A

 

Lamp power factor

Not relevant for halogen incandescent lamps (power factor equals 1).

Chromaticity coordinates

CIE S 010 (= ISO 23539) for basics on photometry,

CIE 15 for basics on colorimetry,

CIE 63 for spectroradio-metric measurement

 

CRI

Not relevant for halogen incandescent lamps (CRI is 100).

Equivalence claim for retrofit lamps

See measurement of luminous flux and power under parameter EEI.

Beam angle

IEC/TR 61341, further conditions EN 60357, Annex A

 

Peak intensity

IEC/TR 61341, further conditions EN 60357, Annex A

 

Lamp type (MR11, GU4, etc.

EN 60357

 

c.

Compact fluorescent lamps with integrated control gear shall be measured according to methods set out in the following documents:

Directional compact fluorescent lamps

Measured parameter

Reference

Remarks

EEI

CIE 84 for general conditions of luminous flux measurement;

L2(AP)005 for cone luminous flux;

EN 60969, at present 34A/1701/CDV Annex A for power.

The average EEI value shall be calculated from the arithmetic mean of each product's individual EEI.

Rated lifetime

EN 60969, at present 34A/1701/CDV Annex G

 

Lamp survival factor

EN 60969, at present 34A/1701/CDV Annex G

 

Lumen maintenance

EN 60969, at present 34A/1701/CDV Annex D

 

Number of switching cycles

EN 60969, at present 34A/1701/CDV Annex F

 

Starting time

EN 60969, at present 34A/1701/CDV Annex B

 

Lamp warm-up time

EN 60969, at present 34A/1701/CDV Annex C

The run-up time shall be used instead.

Premature failure rate

EN 60969, at present 34A/1701/CDV Annex G

 

Lamp power factor

EN 61000-3-2

 

Chromaticity coordinates

CIE 15

 

CCT

CIE 15

 

CRI

CIE 13.3

 

Spectral power distribution

CIE 63

 

Lamp dimensions

EN 60969, at present 34A/1701/CDV Table 3

 

Beam angle

IEC/TR 61341

 

Peak intensity

IEC/TR 61341

 

Mercury content

Commission Decision 2002/747/EC (Annex)

 

Lamp type (MR11, GU4, etc.

EN 60968 at present 34A/1624/CD - caps

 

Cone luminous flux

L2(AP)005

 

Cap

EN 60968

 

d.

High intensity discharge lamps shall be measured according to methods set out in the following documents:

Directional high intensity discharge lamps

Measured parameter

Reference

Remarks

EEI

CIE 84 for general conditions of luminous flux measurement;

L2(AP)005 for cone luminous flux;

EN 61167 Annex B or E for power, for metal halide lamps.

The average EEI value shall be calculated from the arithmetic mean of each product's individual EEI.

Rated lifetime

Reliable, accurate and reproducible measurement procedures shall be used.

Lumen maintenance

Reliable, accurate and reproducible measurement procedures shall be used.

Number of switching cycles

Reliable, accurate and reproducible measurement procedures shall be used.

Starting time

EN 61167, Annex A for electro-magnetic operation, Annex G for square wave operation for metal halide lamps:;

EN 60662 8.2 for high pressure sodium lamps

The method for square wave operation of metal halide lamps shall be considered if “starting time” can be identified as the sum of time for break down, take-over and run-up. (EN 61167, Annex G)

Lamp warm-up time to 60%

EN 61167, Annex A for electro-magnetic operation, Annex G for square wave operation of metal halide lamps.

 

Premature failure rate

Reliable, accurate and reproducible measurement procedures shall be used.

Lamp power factor

(only for lamps with integrated controlgear)

EN 61000-3-2

 

Chromaticity coordinates

CIE 15

 

CCT

CIE 15

 

CRI

CIE 13.3

 

Spectral power distribution

CIE 63

 

Lamp dimensions

EN 61167, 6 for metal halide lamps

 

Beam angle

IEC/TR 61341

 

Peak intensity

IEC/TR 61341, further conditions EN 61167, 4.7 for metal halide lamps

 

Mercury content

Commission Decision 2002/747/EC (Annex)

 

Dimmability

Reliable, accurate and reproducible measurement procedures shall be used.

Lamp type (MR11, GU4, etc.

EN 61167, 6.2.2 for metal halide lamps

 

Cone luminous flux

L2(AP)005

 

e.

Light emitting diode lamps shall be measured according to methods set out in the following documents:

Directional light emitting diodes lamps

Measured parameter

Reference

Remarks

EEI

CIE 84 for general conditions of luminous flux measurement;

L2(AP)005 for cone luminous flux;

EN 62612, 9.3 for efficacy;

EN 62612, 9.1 and Annex A for luminous flux,

EN 62612, 8.1 and Annex A for power

The average EEI value shall be calculated from the arithmetic mean of each product's individual EEI.

Rated lifetime, lamp lifetime

Reliable, accurate and reproducible measurement procedures shall be used.

Lamp survival factor

EN 62612, 11.2

The compliance criteria of the regulations shall be applied.

Lumen maintenance

EN 62612, 11.2

The compliance criteria of the regulations shall be applied.

Number of switching cycles

EN 62612, 11.3.3

 

Starting time

Reliable, accurate and reproducible measurement procedures shall be used. The method described in 34A/1701/CDV (for CFLi) may be adapted.

Lamp warm-up time

Reliable, accurate and reproducible measurement procedures shall be used. The method described in 34A/1701/CDV (for CFLi) may be adapted.

Premature failure rate

EN 62612, 11.2

An additional read point at 1 000 h and the compliance criteria according to the regulations shall be applied.

Lamp power factor (only for lamps with integrated controlgear)

EN 61000-3-2

 

CCT

prEN 13032-4

 

CRI

prEN 13032-4

 

Colour consistency

EN 62612, 10.1

 

Spectral power distribution

CIE 63

 

Lamp dimensions

EN 62612, 6

 

Beam angle

EN 62612, 9.2

 

Peak intensity

EN 62612, 9.2

 

Dimmability

EN 62560, 5.2

The presence of a symbol or warning shall be checked.

Lamp type (MR11, GU4, etc.)

See parameter “cap”.

 

Cone luminous flux

L2(AP)005

 

Cap

EN 62560

 

f.

Light emitting diode modules shall be measured according to methods set out in the following documents:

Directional light emitting diodes modules

Measured parameter

Reference

Remarks

EEI

IEC 62717, at present 34A/1659/CDV, 9.3 efficacy

The average EEI value shall be calculated from the arithmetic mean of each product's individual EEI.

Rated lifetime

 

Reliable, accurate and reproducible measurement procedures shall be used.

Lamp survival factor

IEC 62717, 10.2

The compliance criteria of the regulations shall be applied.

Lumen maintenance

IEC 62717, 10.2

The compliance criteria of the regulations shall be applied.

Number of switching cycles

IEC 62717, at present 34A/1659/CDV, 10.3

 

Starting time

Reliable, accurate and reproducible measurement procedures shall be used. The method described in 34A/1701/CDV (for CFLi) may be adapted.

Lamp warm-up time

Reliable, accurate and reproducible measurement procedures shall be used. The method described in 34A/1701/CDV (for CFLi) may be adapted.

Premature failure rate

IEC 62717, 10.2

An additional read point at 1 000 h and the compliance criteria according to the regulations shall be applied.

Lamp power factor (only for lamps with integrated controlgear)

EN 61000-3-2

 

Chromaticity coordinates

prEN 13032-4

 

Colour consistency

IEC 62717, at present 34A/1659/CDV, 9.1

CIE 15

 

CRI

prEN 13032-4A

 

Spetral power distribution

CIE 63

 

Lamp dimensions

IEC 62717, at present 34A/1659/CDV, 5

 

Beam angle

IEC 62717, at present 34A/1659/CDV, 8.2.5

IEC/TR 61341

 

Peak intensity

IEC 62717, at present 34A/1659/CDV, 8.2.4

IEC/TR 61341

 

Dimmability

IEC 62717, at present 34A/1659/CDV, 6 and 7.2

The presence of a symbol or warning shall be checked.

Cone lumen

L2(AP)005

 

5.

For control gear tests shall be carried out as follows:

Control gear

Measured parameter

Reference

Remarks

Standby power for lighting transformers (halogen and LED)

IEC 62442-3, at present 34C/1019/CDV

 

Standby power for household luminaires

Not relevant for luminaires (determined from the controlgear components).

Fluorescent lamp controlgear efficiency measurement

EN 62442-1, replacing EN 50294

 

High intensity discharge lamp controlgear efficiency measurement

IEC 62442-2, at present 34C/1016/CDV

 

6.

The following reference documents shall be used:

Overview of referenced documents

Reference document

Organisation

Title

Commission Decision 2002/747/EC (Annex)

European Commission

Commission Decision 2002/747/EC of 9 September 2002 establishing revised ecological criteria for the award of the Community ecolabel to light bulbs and amending Decision 1999/568EC.

EN 60061-1

CENELEC

Lamp caps and holders together with gauges for the control of interchangeability and safety

Part 1 – lamp caps

EN 60064

CENELEC

Tungsten filament lamps for domestic and similar general lighting purposes — Performance requirements

EN 60357

CENELEC

Tungsten halogen lamps (non vehicle) — Performance specifications

EN 60432-1

CENELEC

Incandescent lamps – Safety specifications – Part 1: Tungsten filament lamps for domestic and similar general lighting purposes

EN 60432-2

CENELEC

Incandescent lamps – Safety specifications – Part 2: Tungsten halogen lamps for domestic and similar general lighting purposes

EN 60432-3

CENELEC

Incandescent lamps – Safety specifications – Part 3: Tungsten halogen lamps (non-vehicle)

EN 60662

CENELEC

High-pressure sodium vapour lamps – Performance specifications

EN 60968 ed. 2 and 34A/1624/CD

IEC/CENELEC

Self-ballasted lamps for general lighting services – Safety requirements

EN 60969 ed. 2 and 34A/1701/CDV

IEC/CENELEC

Self-ballasted lamps for general lighting services – Performance requirements

EN 61000-3-2

CENELEC

Electromagnetic compatibility (EMC) – Part 3-2: Limits – Limits for harmonic current emissions

(equipment input current ≤ 16 A per phase)

EN 61167

CENELEC

Metal halide lamps – Performance specification

IEC/TR 61341

IEC

Method of measurement of centre beam intensity and beam angle(s) of reflector lamps

EN 62442-1

CENELEC

Energy performance of lamp controlgear – Part 1: Controlgear for fluorescent lamps - Method of measurement to determine the total input power of controlgear circuits and the efficiency of the controlgear

IEC 62442-2; at present 34C/1016/CDV

IEC

Energy performance of lamp controlgear – Part 2: Controlgear for high intensity discharge lamps (excluding fluorescent lamps) – Method of measurement to determine the efficiency of controlgear

IEC 62442-3, at present 34A/1019/CDV

IEC

Energy performance of lamp controlgear – Part 3: Controlgear for halogen lamps and LED modules – Method of measurement to determine the efficiency of the controlgear

EN 62471

CENELEC

Photobiological safety of lamps and lamp systems

EN 62554

CENELEC

Sample preparation for measurement of mercury level in fluorescent lamps

EN 62560

CENELEC

Self-ballasted LED lamps for general lighting services by voltage >50 V – Safety specifications

EN 62612

CENELEC

Self-ballasted LED lamps for general lighting services with supply voltages > 50 V – Performance requirements

IEC 62717, at present 34A/1659/CDV

IEC

LED modules for general lighting - Performance requirements

prEN 13032-4

CEN

Light and lighting - Measurement and presentation of photometric data - Part 4: LED lamps, modules and luminaires

CIE TR 13.3:1995

CIE

Method of Measuring and Specifying Colour Rendering Properties of Light Sources

CIE TR 15:2004

CIE

Colorimetry

CIE 18

CIE

Principles of Light Measurement

CIE 43:1979

CIE

Photometry of Floodlights

CIE TR 53:1982

CIE

Methods of characterizing the performance of radiometers and photometers

CIE 63:1984

CIE

The spectroradiometric measurement of light sources

CIE 70:1987

CIE

The measurement of absolute luminous intensity distributions

CIE TR 84:1989

CIE

The measurement of luminous flux

CIE TR 127:2007

CIE

Measurement of LEDs

CIE TR 149:2002

CIE

The use of tungsten filament lamps as secondary standard sources

CIE S 010/E:2004 / ISO 23539:2005

CIE/ISO

Photometry - The CIE System of Physical Photometry

L2(AP)005, to be converted into an EN standard

European Lamp Manufacturers Association in the Preparation of Standards

Cone luminous flux measurement


(1)  It is intended that these transitional methods will ultimately be replaced by harmonised standards. When available, reference(s) to the harmonised standards will be published in the Official Journal of the European Union in accordance with Articles 9 and 10 of Directive 2009/125/EC.