COMMISSION REGULATION (EC) No 440/2008

of 30 May 2008

laying down test methods pursuant to Regulation (EC) No 1907/2006 of the European Parliament and of the Council on the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH)

(Text with EEA relevance)

▼B

(OJ L 142, 31.5.2008, p.1)

Amended by:

 

 

Official Journal

  No

page

date

►M1

COMMISSION REGULATION (EC) No 761/2009 of 23 July 2009

  L 220

1

24.8.2009

►M2

COMMISSION REGULATION (EU) No 1152/2010 of 8 December 2010

  L 324

13

9.12.2010

►M3

COMMISSION REGULATION (EU) No 640/2012 of 6 July 2012

  L 193

1

20.7.2012


Corrected by:

►C1

Corrigendum, OJ L 143, 3.6.2008, p. 55  (440/2008)




▼B

▼C1

COMMISSION REGULATION (EC) No 440/2008

of 30 May 2008

laying down test methods pursuant to Regulation (EC) No 1907/2006 of the European Parliament and of the Council on the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH)

(Text with EEA relevance)

▼B



THE COMMISSION OF THE EUROPEAN COMMUNITIES,

Having regard to the Treaty establishing the European Community,

Having regard to Regulation (EC) No 1907/2006 of 18 December 2006 of the European Parliament and of the Council concerning the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH), establishing a European Chemicals Agency, amending Directive 1999/45/EC and repealing Council Regulation (EEC) No 793/93 and Commission Regulation (EC) No 1488/94 as well as Council Directive 76/769/EEC and Commission Directives 91/155/EEC, 93/67/EEC, 93/105/EC and 2000/21/EC ( 1 ), and in particular Article 13(3)thereof,

Whereas:

(1)

Pursuant to Regulation (EC) No 1907/2006, test methods are to be adopted at Community level for the purposes of tests on substances where such tests are required to generate information on intrinsic properties of substances.

(2)

Council Directive 67/548/EEC of 27 June 1967 on the approximation of the laws, regulations and administrative provisions relating to the classification, packaging and labelling of dangerous substances ( 2 ), laid down, in Annex V, methods for the determination of the physico-chemical properties, toxicity and ecotoxicity of substances and preparations. Annex V to Directive 67/548/EEC has been deleted by Directive 2006/121/EC of the European Parliament and of the Council with effect from 1 June 2008.

(3)

The test methods contained in Annex V to Directive 67/548/EEC should be incorporated into this Regulation.

(4)

This Regulation does not exclude the use of other test methods, provided that their use is in accordance with Article 13(3) of Regulation 1907/2006.

(5)

The principles of replacement, reduction and refinement of the use of animals in procedures should be fully taken into account in the design of the test methods, in particular when appropriate validated methods become available to replace, reduce or refine animal testing.

(6)

The provisions of this Regulation are in accordance with the opinion of the Committee established under Article 133 of Regulation (EC) No 1907/2006,

HAS ADOPTED THIS REGULATION:



Article 1

The test methods to be applied for the purposes of Regulation 1907/2006/EC are set out in the Annex to this Regulation.

Article 2

The Commission shall review, where appropriate, the test methods contained in this Regulation with a view to replacing, reducing or refining testing on vertebrate animals.

Article 3

All references to Annex V to Directive 67/548/EEC shall be construed as references to this Regulation.

Article 4

This Regulation shall enter into force on the day following its publication in the Official Journal of the European Union.

It shall apply from 1 June 2008.




ANNEX




PART A: METHODS FOR THE DETERMINATION OF PHYSICO-CHEMICAL PROPERTIES

TABLE OF CONTENTS

A.1.

MELTING/FREEZING TEMPERATURE

A.2.

BOILING TEMPERATURE

A.3.

RELATIVE DENSITY

A.4.

VAPOUR PRESSURE

A.5.

SURFACE TENSION

A.6.

WATER SOLUBILITY

A.8.

PARTITION COEFFICIENT

A.9.

FLASH-POINT

A.10.

FLAMMABILITY (SOLIDS)

A.11.

FLAMMABILITY (GASES)

A.12.

FLAMMABILITY (CONTACT WITH WATER)

A.13.

PYROPHORIC PROPERTIES OF SOLIDS AND LIQUIDS

A.14.

EXPLOSIVE PROPERTIES

A.15.

AUTO-IGNITION TEMPERATURE (LIQUIDS AND GASES)

A.16.

RELATIVE SELF-IGNITION TEMPERATURE FOR SOLIDS

A.17.

OXIDISING PROPERTIES (SOLIDS)

A.18.

NUMBER — AVERAGE MOLECULAR WEIGHT AND MOLECULAR WEIGHT DISTRIBUTION OF POLYMERS

A.19.

LOW MOLECULAR WEIGHT CONTENT OF POLYMERS

A.20.

SOLUTION/EXTRACTION BEHAVIOUR OF POLYMERS IN WATER

A.21.

OXIDISING PROPERTIES (LIQUIDS)

A.22.

LENGTH WEIGHTED GEOMETRIC MEAN DIAMETER OF FIBRES

A.1.   MELTING/FREEZING TEMPERATURE

1.   METHOD

The majority of the methods described are based on the OECD Test Guideline (1). The fundamental principles are given in references (2) and (3).

1.1.   INTRODUCTION

The methods and devices described are to be applied for the determination of the melting temperature of substances, without any restriction with respect to their degree of purity.

The selection of the method is dependent on the nature of the substance to be tested. In consequence the limiting factor will be according to, whether or not the substance can be pulverised easily, with difficulty, or not at all.

For some substances, the determination of the freezing or solidification temperature is more appropriate and the standards for these determinations have also been included in this method.

Where, due to the particular properties of the substance, none of the above parameters can be conveniently measured, a pour point may be appropriate.

1.2.   DEFINITIONS AND UNITS

The melting temperature is defined as the temperature at which the phase transition from solid to liquid state occurs at atmospheric pressure and this temperature ideally corresponds to the freezing temperature.

As the phase transition of many substances takes place over a temperature range, it is often described as the melting range.

Conversion of units (K to oC)

t = T - 273,15

t

:

Celsius temperature, degree Celsius (oC)

T

:

thermodynamic temperature, kelvin (K)

1.3.   REFERENCE SUBSTANCES

Reference substances do not need to be employed in all cases when investigating a new substance. They should primarily serve to check the performance of the method from time to time and to allow comparison with results from other methods.

Some calibration substances are listed in the references (4).

1.4.   PRINCIPLE OF THE TEST METHOD

The temperature (temperature range) of the phase transition from the solid to the liquid state or from the liquid to the solid state is determined. In practice while heating/cooling a sample of the test substance at atmospheric pressure the temperatures of the initial melting/freezing and the final stage of melting/freezing are determined. Five types of methods are described, namely capillary method, hot stage methods, freezing temperature determinations, methods of thermal analysis, and determination of the pour point (as developed for petroleum oils).

In certain cases, it may be convenient to measure the freezing temperature in place of the melting temperature.

1.4.1.   Capillary method

1.4.1.1.   Melting temperature devices with liquid bath

A small amount of the finely ground substance is placed in a capillary tube and packed tightly. The tube is heated, together with a thermometer, and the temperature rise is adjusted to less than about 1 K/min during the actual melting. The initial and final melting temperatures are determined.

1.4.1.2.   Melting temperature devices with metal block

As described under 1.4.1.1, except that the capillary tube and the thermometer are situated in a heated metal block, and can be observed through holes in the block.

1.4.1.3.   Photocell detection

The sample in the capillary tube is heated automatically in a metal cylinder. A beam of light is directed through the substance, by way of a hole in the cylinder, to a precisely calibrated photocell. The optical properties of most substances change from opaque to transparent when they are melting. The intensity of light reaching the photocell increases and sends a stop signal to the digital indicator reading out the temperature of a platinum resistance thermometer located in the heating chamber. This method is not suitable for some highly coloured substances.

1.4.2.   Hot stages

1.4.2.1.   Kofler hot bar

The Kofler hot bar uses two pieces of metal of different thermal conductivity, heated electrically, with the bar designed so that the temperature gradient is almost linear along its length. The temperature of the hot bar can range from 283 to 573 K with a special temperature-reading device including a runner with a pointer and tab designed for the specific bar. In order to determine a melting temperature, the substance is laid, in a thin layer, directly on the surface of the hot bar. In a few seconds a sharp dividing line between the fluid and solid phase develops. The temperature at the dividing line is read by adjusting the pointer to rest at the line.

1.4.2.2.   Melt microscope

Several microscope hot stages are in use for the determination of melting temperatures with very small quantities of material. In most of the hot stages the temperature is measured with a sensitive thermocouple but sometimes mercury thermometers are used. A typical microscope hot stage melting temperature apparatus has a heating chamber which contains a metal plate upon which the sample is placed on a slide. The centre of the metal plate contains a hole permitting the entrance of light from the illuminating mirror of the microscope. When in use, the chamber is closed by a glass plate to exclude air from the sample area.

The heating of the sample is regulated by a rheostat. For very precise measurements on optically anisotropic substances, polarised light may be used.

1.4.2.3.   Meniscus method

This method is specifically used for polyamides.

The temperature at which the displacement of a meniscus of silicone oil, enclosed between a hot stage and a cover-glass supported by the polyamide test specimen, is determined visually.

1.4.3.   Method to determine the freezing temperature

The sample is placed in a special test tube and placed in an apparatus for the determination of the freezing temperature. The sample is stirred gently and continuously during cooling and the temperature is measured at suitable intervals. As soon as the temperature remains constant for a few readings this temperature (corrected for thermometer error) is recorded as the freezing temperature.

Supercooling must be avoided by maintaining equilibrium between the solid and the liquid phases.

1.4.4.   Thermal analysis

1.4.4.1   Differential thermal analysis (DTA)

This technique records the difference in temperatures between the substance and a reference material as a function of temperature, while the substance and reference material are subjected to the same controlled temperature programme. When the sample undergoes a transition involving a change of enthalpy, that change is indicated by an endothermic (melting) or exothermic (freezing) departure from the base line of the temperature record.

1.4.4.2   Differential scanning calorimetry (DSC)

This technique records the difference in energy inputs into a substance and a reference material, as a function of temperature, while the substance and reference material are subjected to the same controlled temperature programme. This energy is the energy necessary to establish zero temperature difference between the substance and the reference material. When the sample undergoes a transition involving a change of enthalpy, that change is indicated by an endothermic (melting) or exothermic (freezing) departure from the base line of the heat flow record.

1.4.5.   Pour point

This method was developed for use with petroleum oils and is suitable for use with oily substances with low melting temperatures.

After preliminary heating, the sample is cooled at a specific rate and examined at intervals of 3 K for flow characteristics. The lowest temperature at which movement of the substance is observed is recorded as the pour point.

1.5.   QUALITY CRITERIA

The applicability and accuracy of the different methods used for the determination of the melting temperature/melting range are listed in the following table:

TABLE: APPLICABILITY OF THE METHODS



A.  Capillary methods

Method of measurement

Substances which can be pulverised

Substances which are not readily pulverised

Temperature range

Estimated accuracy (1)

Existing standards

Melting temperature devices with liquid bath

yes

only to a few

273 to 573 K

± 0,3 K

JIS K 0064

Melting temperature with metal block

yes

only to a few

293 to >573 K

± 0,5 K

ISO 1218 (E)

Photocell detection

yes

several with appliance devices

253 to 573 K

± 0,5 K

 

(1)   Dependent on type of instrument and on degree of purity of the substance.



B.  Hot stages and freezing methods

Method of measurement

Substances which can be pulverised

Substances which are not readily pulverised

Temperature range

Estimated accuracy (1)

Existing standards

Kofler hot bar

yes

no

283 to > 573 K

± 1K

ANSI/ASTM D 3451-76

Melt microscope

yes

only to a few

273 to > 573 K

± 0,5 K

DIN 53736

Meniscus method

no

specifically for polyamides

293 to > 573 K

± 0,5 K

ISO 1218 (E)

Freezing temperature

yes

yes

223 to 573 K

± 0,5 K

e.g. BS 4695

(1)   Dependent on type of instrument and on degree of purity of the substance



C.  Thermal analysis

Method of measurement

Substances which can be pulverised

Substances which are not readily pulverised

Temperature range

Estimated accuracy (1)

Existing standards

Differential thermal analysis

yes

yes

173 to 1 273 K

up to 600 K ± 0,5 K up to 1 273 K ± 2,0 K

ASTM E 537-76

Differential scanning calorimetry

yes

yes

173 to 1 273 K

up to 600 K ± 0,5 K up to 1 273 K ± 2,0 K

ASTM E 537-76

(1)   Dependent on type of instrument and on degree of purity of the substance



D.  Pour point

Method of measurement

Substances which can be pulverised

Substances which are not readily pulverised

Temperature range

Estimated accuracy (1)

Existing standards

Pour point

for petroleum oils and oily substances

for petroleum oils and oily substances

223 to 323 K

± 0,3 K

ASTM D 97-66

(1)   Dependent on type of instrument and on degree of purity of the substance

1.6.   DESCRIPTION OF THE METHODS

The procedures of nearly all the test methods have been described in international and national standards (see Appendix 1).

1.6.1.   Methods with capillary tube

When subjected to a slow temperature rise, finely pulverised substances usually show the stages of melting shown in figure 1.

Stage AStage BStage CStage DStage EStage A(beginning of melting): fine droplets adhere uniformly to the inside wall of the capillary tubeStage Ba clearance appears between the sample and the inside wall due to shrinkage of the meltStage Cthe shrunken sample begins to collapse downwards and liquefiesStage Da complete meniscus is formed at the surface but an appreciate amount of the sample remains solidStage E(final stage melting): there are no solid particles

During the determination of the melting temperature, the temperatures are recorded at the beginning of the melting and at the final stage.

1.6.1.1.   Melting temperature devices with liquid bath apparatus

Figure 2 shows a type of standardised melting temperature apparatus made of glass (JIS K 0064); all specifications are in millimeters.

A: Measurement vesselB: StopperC: VentD: ThermometerE: Auxiliary thermometerF: Bath liquidG: Capillary tube made of glass, 80 to 100 mm in length, 1,0 ± 0,2 mm inner diameter, 0,2 to 0,3 mm wall thicknessH: Side tube

A suitable liquid should be chosen. The choice of the liquid depends upon the melting temperature to be determined, e.g. liquid paraffin for melting temperatures no higher than 473 K, silicone oil for melting temperatures no higher than 573 K.

For melting temperatures above 523 K, a mixture consisting of three parts sulphuric acid and two parts potassium sulphate (in mass ratio) can be used. Suitable precautions should be taken if a mixture such as this is used.

Only those thermometers should be used which fulfil the requirements of the following or equivalent standards:

ASTM E 1-71, DIN 12770, JIS K 8001.

The dry substance is finely pulverised in a mortar and is put into the capillary tube, fused at one end, so that the filling level is approximately 3 mm after being tightly packed. To obtain a uniform packed sample, the capillary tube should be dropped from a height of approximately 700 mm through a glass tube vertically onto a watch glass.

The filled capillary tube is placed in the bath so that the middle part of the mercury bulb of the thermometer touches the capillary tube at the part where the sample is located. Usually the capillary tube is introduced into the apparatus about 10 K below the melting temperature.

The bath liquid is heated so that the temperature rise is approximately 3 K/min. The liquid should be stirred. At about 10 K below the expected melting temperature the rate of temperature rise is adjusted to a maximum of 1 K/min.

The calculation of the melting temperature is as follows:

T = TD + 0,00016 (TD - TE) n

where:

T

=

corrected melting temperature in K

TD

=

temperature reading of thermometer D in K

TE

=

temperature reading of thermometer E in K

n

=

number of graduations of mercury thread on thermometer D at emergent stem.

1.6.1.2.   Melting temperature devices with metal block

This consists of:

 a cylindrical metal block, the upper part of which is hollow and forms a chamber (see figure 3),

 a metal plug, with two or more holes, allowing tubes to be mounted into the metal block,

 a heating system, for the metal block, provided for example by an electrical resistance enclosed in the block,

 a rheostat for regulation of power input, if electric heating is used,

 four windows of heat-resistant glass on the lateral walls of the chamber, diametrically disposed at right-angles to each other. In front of one of these windows is mounted an eye-piece for observing the capillary tube. The other three windows are used for illuminating the inside of the enclosure by means of lamps,

 a capillary tube of heat-resistant glass closed at one end (see 1.6.1.1).

See standards mentioned in 1.6.1.1. Thermoelectrical measuring devices with comparable accuracy are also applicable.

ThermometerCapillary tubeMetal plugEye-pieceLampElectrical resistanceMetal heating block

1.6.1.3.   Photocell detection

Apparatus and procedure:

The apparatus consists of a metal chamber with automated heating system. Three capillary are filled accordingly to 1.6.1.1 and placed in the oven.

Several linear increases of temperature are available for calibrating the apparatus and the suitable temperature rise is electrically adjusted at a pre-selected constant and linear rate. recorders show the actual oven temperature and the temperature of the substance in the capillary tubes.

1.6.2.   Hot stages

1.6.2.1.   Kofler hot bar

See Appendix.

1.6.2.2.   Melt microscope

See Appendix.

1.6.2.3.   Meniscus method (polyamides)

See Appendix.

The heating rate through the melting temperature should be less than 1 K/min.

1.6.3.   Methods for the determination of the freezing temperature

See Appendix.

1.6.4.   Thermal analysis

1.6.4.1.   Differential thermal analysis

See Appendix.

1.6.4.2.   Differential scanning calorimetry

See Appendix.

1.6.5.   Determination of the pour point

See Appendix.

2.   DATA

A thermometer correction is necessary in some cases.

3.   REPORTING

The test report shall, if possible, include the following information:

 method used,

 precise specification of the substance (identity and impurities) and preliminary purification step, if any,

 an estimate of the accuracy.

The mean of at least two measurements which are in the range of the estimated accuracy (see tables) is reported as the melting temperature.

If the difference between the temperature at the beginning and at the final stage of melting is within the limits of the accuracy of the method, the temperature at the final stage of melting is taken as the melting temperature; otherwise the two temperatures are reported.

If the substance decomposes or sublimes before the melting temperature is reached, the temperature at which the effect is observed shall be reported.

All information and remarks relevant for the interpretation of results have to be reported, especially with regard to impurities and physical state of the substance.

4.   REFERENCES

(1) OECD, Paris, 1981, Test Guideline 102, Decision of the Council C(81) 30 final.

(2) IUPAC, B. Le Neindre, B. Vodar, eds. Experimental thermodynamics, Butterworths, London 1975, vol. II, p. 803-834.

(3) R. Weissberger ed.: Technique of organic Chemistry, Physical Methods of Organic Chemistry, 3rd ed., Interscience Publ., New York, 1959, vol. I, Part I, Chapter VII.

(4) IUPAC, Physicochemical measurements: Catalogue of reference materials from national laboratories, Pure and applied chemistry, 1976, vol. 48, p. 505-515.

Appendix

For additional technical details, the following standards may be consulted for example.

1.   Capillary methods

1.1.   Melting temperature devices with liquid bath



ASTM E 324-69

Standard test method for relative initial and final melting points and the melting range of organic chemicals

BS 4634

Method for the determination of melting point and/or melting range

DIN 53181

Bestimmung des Schmelzintervalles von Harzen nach Kapillarverfarehn

JIS K 00-64

Testing methods for melting point of chemical products

1.2.   Melting temperature devices with metal block



DIN 53736

Visuelle Bestimmung der Schmelztemperatur von teilkristallinen Kunststoffen

ISO 1218 (E)

Plastics — polyamides — determination of ‘melting point’

2.   Hot stages

2.1.   Kofler hot bar



ANSI/ASTM D 3451-76

Standard recommended practices for testing polymeric powder coatings

2.2.   Melt microscope



DIN 53736

Visuelle Bestimmung der Schmelztemperatur von teilkristallinen Kunststoffen

2.3.   Meniscus method (polyamides)



ISO 1218 (E)

Plastics — polyamides — determination of ‘melting point’

ANSI/ASTM D 2133-66

Standard specification for acetal resin injection moulding and extrusion materials

NF T 51-050

Résines de polyamides. Détermination du ‘point de fusion’ méthode du ménisque

3.   Methods for the determination of the freezing temperature



BS 4633

Method for the determination of crystallising point

BS 4695

Method for Determination of Melting Point of petroleum wax (Cooling Curve)

DIN 51421

Bestimmung des Gefrierpunktes von Flugkraftstoffen, Ottokraftstoffen und Motorenbenzolen

ISO 2207

Cires de pétrole: détermination de la température de figeage

DIN 53175

Bestimmung des Erstarrungspunktes von Fettsäuren

NF T 60-114

Point de fusion des paraffines

NF T 20-051

Méthode de détermination du point de cristallisation (point de congélation)

ISO 1392

Method for the determination of the freezing point

4.   Thermal analysis

4.1.   Differential thermal analysis



ASTM E 537-76

Standard method for assessing the thermal stability of chemicals by methods of differential thermal analysis

ASTM E 473-85

Standard definitions of terms relating to thermal analysis

ASTM E 472-86

Standard practice for reporting thermoanalytical data

DIN 51005

Thermische Analyse, Begriffe

4.2.   Differential scanning calorimetry



ASTM E 537-76

Standard method for assessing the thermal stability of chemicals by methods of differential thermal analysis

ASTM E 473-85

Standard definitions of terms relating to thermal analysis

ASTM E 472-86

Standard practice for reporting thermoanalytical data

DIN 51005

Thermische Analyse, Begriffe

5.   Determination of the pour point



NBN 52014

Echantillonnage et analyse des produits du pétrole: Point de trouble et point d'écoulement limite — Monsterneming en ontleding van aardolieproducten: Troebelingspunt en vloeipunt

ASTM D 97-66

Standard test method for pour point of petroleum oils

ISO 3016

Petroleum oils — Determination of pour point

A.2.   BOILING TEMPERATURE

1.   METHOD

The majority of the methods described are based on the OECD Test Guideline (1). The fundamental principles are given in references (2) and (3).

1.1.   INTRODUCTION

The methods and devices described here can be applied to liquid and low melting substances, provided that these do not undergo chemical reaction below the boiling temperature (for example: auto-oxidation, rearrangement, degradation, etc.). The methods can be applied to pure and to impure liquid substances.

Emphasis is put on the methods using photocell detection and thermal analysis, because these methods allow the determination of melting as well as boiling temperatures. Moreover, measurements can be performed automatically.

The ‘dynamic method’ has the advantage that it can also be applied to the determination of the vapour pressure and it is not necessary to correct the boiling temperature to the normal pressure (101,325 kPa) because the normal pressure can be adjusted during the measurement by a manostat.

Remarks:

The influence of impurities on the determination of the boiling temperature depends greatly upon the nature of the impurity. When there are volatile impurities in the sample, which could affect the results, the substance may be purified.

1.2.   DEFINITIONS AND UNITS

The normal boiling temperature is defined as the temperature at which the vapour pressure of a liquid is 101,325 kPa.

If the boiling temperature is not measured at normal atmospheric pressure, the temperature dependence of the vapour pressure can be described by the Clausius-Clapeyron equation:

image

where:

p

=

the vapour pressure of the substance in pascals

Δ Hv

=

its heat of vaporisation in J mol-1

R

=

the universal molar gas constant = 8,314 J mol-1 K-1

T

=

thermodynamic temperature in K

The boiling temperature is stated with regard to the ambient pressure during the measurement.

Conversions

Pressure (units: kPa)

100 kPa

=

1 bar = 0,1 MPa

(‘bar’ is still permissible but not recommended)

133 Pa

=

1 mm Hg = 1 Torr

(the units ‘mm Hg’ and ‘Torr’ are not permitted)

1 atm

=

standard atmosphere = 101 325 Pa

(the unit ‘atm’ is not permitted)

Temperature (units: K)

t = T - 273,15

t

:

Celsius temperature, degree Celsius (oC)

T

:

thermodynamic temperature, kelvin (K)

1.3.   REFERENCE SUBSTANCES

Reference substances do not need to be employed in all cases when investigating a new substance. They should primarily serve to check the performance of the method from time to time and to allow comparison with results from other methods.

Some calibration substances can be found in the methods listed in the Appendix.

1.4.   PRINCIPLE OF THE TEST METHOD

Five methods for the determination of the boiling temperature (boiling range) are based on the measurement of the boiling temperature, two others are based on thermal analysis.

1.4.1.   Determination by use of the ebulliometer

Ebulliometers were originally developed for the determination of the molecular weight by boiling temperature elevation, but they are also suited for exact boiling temperature measurements. A very simple apparatus is described in ASTM D 1120-72 (see Appendix). The liquid is heated in this apparatus under equilibrium conditions at atmospheric pressure until it is boiling.

1.4.2.   Dynamic method

This method involves the measurement of the vapour recondensation temperature by means of an appropriate thermometer in the reflux while boiling. The pressure can be varied in this method.

1.4.3.   Distillation method for boiling temperature

This method involves distillation of the liquid and measurement of the vapour recondensation temperature and determination of the amount of distillate.

1.4.4.   Method according to Siwoloboff

A sample is heated in a sample tube, which is immersed in a liquid in a heat-bath. A fused capillary, containing an air bubble in the lower part, is dipped in the sample tube.

1.4.5.   Photocell detection

Following the principle according to Siwoloboff, automatic photo-electrical measurement is made using rising bubbles.

1.4.6.   Differential thermal analysis

This technique records the difference in temperatures between the substance and a reference material as a function of temperature, while the substance and reference material are subjected to the same controlled temperature programme. When the sample undergoes a transition involving a change of enthalpy, that change is indicated by an endothermic departure (boiling) from the base line of the temperature record.

1.4.7.   Differential scanning calorimetry

This technique records the difference in energy inputs into a substance and a reference material as a function of temperature, while the substance and reference material are subjected to the same controlled temperature programme. This energy is the energy necessary to establish zero temperature difference between the substance and the reference material. When the sample undergoes a transition involving a change of enthalpy, that change is indicated by an endothermic departure (boiling) from the base line of the heat flow record.

1.5.   QUALITY CRITERIA

The applicability and accuracy of the different methods used for the determination of the boiling temperature/boiling range are listed in table 1.



Table 1:

Comparison of the methods

Method of measurement

Estimated accuracy

Existing standard

Ebulliometer

± 1,4 K (up to 373 K) (1) (2)

± 2,5 K (up to 600 K) (1) (2)

ASTM D 1120-72 (1)

Dynamic method

± 0,5 K (up to 600 K) (2)

 

Distillation process (boiling range)

± 0,5 K (up to 600 K)

ISO/R 918, DIN 53171, BS 4591/71

According to Siwoloboff

± 2 K (up to 600 K) (2)

 

Photocell detection

± 0,3 K (up to 373 K) (2)

 

Differential thermal calorimetry

± 0,5 K (up to 600 K)

± 2,0 K (up to 1 273 K)

ASTM E 537-76

Differential scanning calorimetry

± 0,5 K (up to 600 K)

± 2,0 K (up to 1 273 K)

ASTM E 537-76

(1)   This accuracy is only valid for the simple device as for example described in ASTM D 1120-72; it can be improved with more sophisticated ebulliometer devices.

(2)   Only valid for pure substances. The use in other circumstances should be justified.

1.6.   DESCRIPTION OF THE METHODS

The procedures of some test methods have been described in international and national standards (see Appendix).

1.6.1.   Ebulliometer

See Appendix.

1.6.2.   Dynamic method

See test method A.4 for the determination of the vapour pressure.

The boiling temperature observed with an applied pressure of 101,325 kPa is recorded.

1.6.3.   Distillation process (boiling range)

See Appendix.

1.6.4.   Method according to Siwoloboff

The sample is heated in a melting temperature apparatus in a sample tube, with a diameter of approximately 5 mm (figure 1).

Figure 1 shows a type of standardised melting and boiling temperature apparatus (JIS K 0064) (made of glass, all specifications in millimetres).

A: Measuring vesselB: StopperC: VentD: ThermometerE: Auxiliary thermometerF: Bath liquidG: Sample tube, maximum 5 mm outer diameter; containing a capillary tube, approximately 100 mm long, approximately 1 mm long inner diameter and approximately 0,2 to 0,3 mm wall-thicknessH: Side tube

A capillary tube (boiling capillary) which is fused about 1 cm above the lower end is placed in the sample tube. The level to which the test substance is added is such that the fused section of the capillary is below the surface of the liquid. The sample tube containing the boiling capillary is fastened either to the thermometer with a rubber band or is fixed with a support from the side (see figure 2).



Figure 2

Principle according to Siwoloboff

Figure 3

Modified principle

image

image

The bath liquid is chosen according to boiling temperature. At temperatures up to 573 K, silicone oil can be used. Liquid paraffin may only be used up to 473 K. The heating of the bath liquid should be adjusted to a temperature rise of 3 K/min at first. The bath liquid must be stirred. At about 10 K below the expected boiling temperature, the heating is reduced so that the rate of temperature rise is less than 1 K/min. Upon approach of the boiling temperature, bubbles begin to emerge rapidly from the boiling capillary.

The boiling temperature is that temperature when, on momentary cooling, the string of bubbles stops and fluid suddenly starts rising in the capillary. The corresponding thermometer reading is the boiling temperature of the substance.

In the modified principle (figure 3) the boiling temperature is determined in a melting temperature capillary. It is stretched to a fine point about 2 cm in length (a) and a small amount of the sample is sucked up. The open end of the fine capillary is closed by melting, so that a small air bubble is located at the end. While heating in the melting temperature apparatus (b), the air bubble expands. The boiling temperature corresponds to the temperature at which the substance plug reaches the level of the surface of the bath liquid (c).

1.6.5.   Photocell detection

The sample is heated in a capillary tube inside a heated metal block.

A light beam is directed, via suitable holes in the block, through the substance onto a precisely calibrated photocell.

During the increase of the sample temperature, single air bubbles emerge from the boiling capillary. When the boiling temperature is reached the number of bubbles increases greatly. This causes a change in the intensity of light, recorded by a photocell, and gives a stop signal to the indicator reading out the temperature of a platinum resistance thermometer located in the block.

This method is especially useful because it allows determinations below room temperature down to 253,15 K (– 20 oC) without any changes in the apparatus. The instrument merely has to be placed in a cooling bath.

1.6.6.   Thermal analysis

1.6.6.1.   Differential thermal analysis

See Appendix.

1.6.6.2.   Differential scanning calorimetry

See Appendix.

2.   DATA

At small deviations from the normal pressure (max. ± 5 kPa) the boiling temperatures are normalised to Tn by means of the following number-value equation by Sidney Young:

Tn = T + (fT × Δp)

where:

Δp

=

(101,325 - p) [note sign]

P

=

pressure measurement in kPa

fT

=

rate of change of boiling temperature with pressure in K/kPa

T

=

measured boiling temperature in K

Tn

=

boiling temperature corrected to normal pressure in K

The temperature-correction factors, fT, and equations for their approximation are included in the international and national standards mentioned above for many substances.

For example, the DIN 53171 method mentions the following rough corrections for solvents included in paints:



Table 2:

Temperature — corrections factors fT

Temperature T (K)

Correction factor fT (K/kPa)

323,15

0,26

348,15

0,28

373,15

0,31

398,15

0,33

423,15

0,35

448,15

0,37

473,15

0,39

498,15

0,41

523,15

0,4

548,15

0,45

573,15

0,47

3.   REPORTING

The test report shall, if possible, include the following information:

 method used,

 precise specification of the substance (identity and impurities) and preliminary purification step, if any,

 an estimate of the accuracy.

The mean of at least two measurements which are in the range of the estimated accuracy (see table 1) is reported as the boiling temperature.

The measured boiling temperatures and their mean shall be stated and the pressure(s) at which the measurements were made shall be reported in kPa. The pressure should preferably be close to normal atmospheric pressure.

All information and remarks relevant for the interpretation of results have to be reported, especially with regard to impurities and physical state of the substance.

4.   REFERENCES

(1) OECD, Paris, 1981, Test Guideline 103, Decision of the Council C (81) 30 final.

(2) IUPAC, B. Le Neindre, B. Vodar, editions. Experimental thermodynamics, Butterworths, London, 1975, vol. II.

(3) R. Weissberger edition: Technique of organic chemistry, Physical methods of organic chemistry, Third Edition, Interscience Publications, New York, 1959, vol. I, Part I, Chapter VIII.

Appendix

For additional technical details, the following standards may be consulted for example.

1.   Ebulliometer

1.1. Melting temperature devices with liquid bath



ASTM D 1120-72

Standard test method for boiling point of engine anti-freezes

2.   Distillation process (boiling range)



ISO/R 918

Test Method for Distillation (Distillation Yield and Distillation Range)

BS 4349/68

Method for determination of distillation of petroleum products

BS 4591/71

Method for the determination of distillation characteristics

DIN 53171

Losungsmittel für Anstrichstoffe, Bestimmung des Siedeverlaufes

NF T 20-608

Distillation: détermination du rendement et de l'intervalle de distillation

3.   Differential thermal analysis and differential scanning calorimetry



ASTM E 537-76

Standard method for assessing the thermal stability of chemicals by methods of differential thermal analysis

ASTM E 473-85

Standard definitions of terms relating to thermal analysis

ASTM E 472-86

Standard practice for reporting thermoanalytical data

DIN 51005

Thermische Analyse, Begriffe

A.3.   RELATIVE DENSITY

1.   METHOD

The methods described are based on the OECD Test Guideline (1). The fundamental principles are given in reference (2).

1.1.   INTRODUCTION

The methods for determining relative density described are applicable to solid and to liquid substances, without any restriction in respect to their degree of purity. The various methods to be used are listed in table 1.

1.2.   DEFINITIONS AND UNITS

The relative density D20 4 of solids or liquids is the ratio between the mass of a volume of substance to be examined, determined at 20 oC, and the mass of the same volume of water, determined at 4 oC. The relative density has no dimension.

The density, ρ, of a substance is the quotient of the mass, m, and its volume, v.

The density, ρ, is given, in SI units, in kg/m3.

1.3.   REFERENCE SUBSTANCES (1) (3)

Reference substances do not need to be employed in all cases when investigating a new substance. They should primarily serve to check the performance of the method from time to time and to allow comparison with results from other methods.

1.4.   PRINCIPLE OF THE METHODS

Four classes of methods are used.

1.4.1.   Buoyancy methods

1.4.1.1.   Hydrometer (for liquid substances)

Sufficiently accurate and quick determinations of density may be obtained by the floating hydrometers, which allow the density of a liquid to be deduced from the depth of immersion by reading a graduated scale.

1.4.1.2.   Hydrostatic balance (for liquid and solid substances)

The difference between the weight of a test sample measured in air and in a suitable liquid (e.g. water) can be employed to determine its density.

For solids, the measured density is only representative of the particular sample employed. For the determination of density of liquids, a body of known volume, v, is weighed first in air and then in the liquid.

1.4.1.3.   Immersed body method (for liquid substances) (4)

In this method, the density of a liquid is determined from the difference between the results of weighing the liquid before and after immersing a body of known volume in the test liquid.

1.4.2.   Pycnometer methods

For solids or liquids, pycnometers of various shapes and with known volumes may be employed. The density is calculated from the difference in weight between the full and empty pycnometer and its known volume.

1.4.3.   Air comparison pycnometer (for solids)

The density of a solid in any form can be measured at room temperature with the gas comparison pycnometer. The volume of a substance is measured in air or in an inert gas in a cylinder of variable calibrated volume. For the calculation of density one mass measurement is taken after concluding the volume measurement.

1.4.4.   Oscillating densitimeter (5) (6) (7)

The density of a liquid can be measured by an oscillating densitimeter. A mechanical oscillator constructed in the form of a U-tube is vibrated at the resonance frequency of the oscillator which depends on its mass. Introducing a sample changes the resonance frequency of the oscillator. The apparatus has to be calibrated by two liquid substances of known densities. These substances should preferably be chosen such that their densities span the range to be measured.

1.5.   QUALITY CRITERIA

The applicability of the different methods used for the determination of the relative density is listed in the table.

1.6.   DESCRIPTION OF THE METHODS

The standards given as examples, which are to be consulted for additional technical details, are attached in the Appendix.

The tests have to be run at 20 oC, and at least two measurements performed.

2.   DATA

See standards.

3.   REPORTING

The test report shall, if possible, include the following information:

 method used,

 precise specification of the substance (identity and impurities) and preliminary purification step, if any.

The relative density,

image

, shall be reported as defined in 1.2, along with the physical state of the measured substance.

All information and remarks relevant for the interpretation of results have to be reported, especially with regard to impurities and physical state of the substance.



Table:

Applicability of methods

Method of measurement

Density

Maximum possible dynamic viscosity

Existing Standards

solid

liquid

1.4.1.1.  Hydrometer

 

yes

5 Pa s

ISO 387,

ISO 649-2,

NF T 20-050

1.4.1.2.  Hydrostatic balance

 
 
 
 

(a)  solids

yes

 
 

ISO 1183 (A)

(b)  liquids

 

yes

5 Pa s

ISO 901 and 758

1.4.1.3.  Immersed body method

 

yes

20 Pa s

DIN 53217

1.4.2.  Pycnometer

 
 
 

ISO 3507

(a)  solids

yes

 
 

ISO 1183(B),

NF T 20-053

(b)  liquids

 

yes

500 Pa s

ISO 758

1.4.3.  Air comparison pycnometer

yes

 
 

DIN 55990 Teil 3,

DIN 53243

1.4.4.  Oscillating densitimer

 

yes

5 Pa s

 

4.   REFERENCES

(1) OECD, Paris, 1981, Test Guideline 109, Decision of the Council C(81) 30 final.

(2) R. Weissberger ed., Technique of Organic Chemistry, Physical Methods of Organic Chemistry, 3rd ed., Chapter IV, Interscience Publ., New York, 1959, vol. I, Part 1.

(3) IUPAC, Recommended reference materials for realization of physico-chemical properties, Pure and applied chemistry, 1976, vol. 48, p. 508.

(4) Wagenbreth, H., Die Tauchkugel zur Bestimmung der Dichte von Flüssigkeiten, Technisches Messen tm, 1979, vol. II, p. 427-430.

(5) Leopold, H., Die digitale Messung von Flüssigkeiten, Elektronik, 1970, vol. 19, p. 297-302.

(6) Baumgarten, D., Füllmengenkontrolle bei vorgepackten Erzeugnissen -Verfahren zur Dichtebestimmung bei flüssigen Produkten und ihre praktische Anwendung, Die Pharmazeutische Industrie, 1975, vol. 37, p. 717-726.

(7) Riemann, J., Der Einsatz der digitalen Dichtemessung im Brauereilaboratorium, Brauwissenschaft, 1976, vol. 9, p. 253-255.

Appendix

For additional technical details, the following standards may be consulted for example.

1.   Buoyancy methods

1.1.   Hydrometer



DIN 12790, ISO 387

Hydrometer; general instructions

DIN 12791

Part I: Density hydrometers; construction, adjustment and use

Part II: Density hydrometers; standardised sizes, designation

Part III: Use and test

ISO 649-2

Laboratory glassware: Density hydrometers for general purpose

NF T 20-050

Chemical products for industrial use — Determination of density of liquids — Areometric method

DIN 12793

Laboratory glassware: range find hydrometers

1.2.   Hydrostatic balance



ISO 1183

Method A: Methods for determining the density and relative density of plastics excluding cellular plastics

NF T 20-049

Chemical products for industrial use — Determination of the density of solids other than powders and cellular products — Hydrostatic balance method

ASTM-D-792

Specific gravity and density of plastics by displacement

DIN 53479

Testing of plastics and elastomers; determination of density



ISO 901

ISO 758

DIN 51757

Testing of mineral oils and related materials; determination of density

ASTM D 941-55, ASTM D 1296-67 and ASTM D 1481-62

ASTM D 1298

Density, specific gravity or API gravity of crude petroleum and liquid petroleum products by hydrometer method

BS 4714

Density, specific gravity or API gravity of crude petroleum and liquid petroleum products by hydrometer method

1.3.   Immersed body method



DIN 53217

Testing of paints, varnishes and similar coating materials; determination of density; immersed body method

2.   Pycnometer methods

2.1.   For liquid substances



ISO 3507

Pycnometers

ISO 758

Liquid chemical products; determination of density at 20 oC

DIN 12797

Gay-Lussac pycnometer (for non-volatile liquids which are not too viscous)

DIN 12798

Lipkin pycnometer (for liquids with a kinematic viscosity of less than 100 10-6 m2 s-1 at 15 oC)

DIN 12800

Sprengel pycnometer (for liquids as DIN 12798)

DIN 12801

Reischauer pycnometer (for liquids with a kinematic viscosity of less than 100. 10-6 m2 s-1 at 20 oC, applicable in particular also to hydrocarbons and aqueous solutions as well as to liquids with higher vapour pressure, approximately 1 bar at 90 oC)

DIN 12806

Hubbard pycnometer (for viscous liquids of all types which do not have too high a vapour pressure, in particular also for paints, varnishes and bitumen)

DIN 12807

Bingham pycnometer (for liquids, as in DIN 12801)

DIN 12808

Jaulmes pycnometer (in particular for ethanol — water mixture)

DIN 12809

Pycnometer with ground-in thermometer and capillary side tube (for liquids which are not too viscous)

DIN 53217

Testing of paints, varnishes and similar products; determination of density by pycnometer

DIN 51757

Point 7: Testing of mineral oils and related materials; determination of density

ASTM D 297

Section 15: Rubber products — chemical analysis

ASTM D 2111

Method C: Halogenated organic compounds

BS 4699

Method for determination of specific gravity and density of petroleum products (graduated bicapillary pycnometer method)

BS 5903

Method for determination of relative density and density of petroleum products by the capillary — stoppered pycnometer method

NF T 20-053

Chemical products for industrial use — Determination of density of solids in powder and liquids — Pyknometric method

2.2.   For solid substances



ISO 1183

Method B: Methods for determining the density and relative density of plastics excluding cellular plastics

NF T 20-053

Chemical products for industrial use — Determination of density of solids in powder and liquids — Pyknometric method

DIN 19683

Determination of the density of soils

3.   Air comparison pycnometer



DIN 55990

Part 3: Prüfung von Anstrichstoffen und ähnlichen Beschichtungsstoffen; Pulverlack; Bestimmung der Dichte

DIN 53243

Anstrichstoffe; chlorhaltige Polymere; Prüfung

▼M1

A.4.   VAPOUR PRESSURE

1.   METHOD

This method is equivalent to OECD TG 104 (2004).

1.1.   INTRODUCTION

This revised version of method A.4(1) includes one additional method; Effusion method: isothermal thermogravimetry, designed for substances with very low pressures (down to 10–10 Pa). In the light of needs for procedures, especially in relation to obtaining vapour pressure for substances with low vapour pressure, other procedures of this method are re-evaluated with respect to other applicability ranges.

At the thermodynamic equilibrium the vapour pressure of a pure substance is a function of temperature only. The fundamental principles are described elsewhere (2)(3).

No single measurement procedure is applicable to the entire range of vapour pressures from less than 10–10 to 105 Pa. Eight methods for measuring vapour pressure are included in this method which can be applied in different vapour pressure ranges. The various methods are compared as to application and measuring range in Table 1. The methods can only be applied for compounds that do not decompose under the conditions of the test. In cases where the experimental methods cannot be applied due to technical reasons, the vapour pressure can also be estimated, and a recommended estimation method is set out in the Appendix.

1.2.   DEFINITIONS AND UNITS

The vapour pressure of a substance is defined as the saturation pressure above a solid or liquid substance.

The SI unit of pressure, which is the pascal (Pa), should be used. Other units which have been employed historically are given hereafter, together with their conversion factors:



1 Torr

=

1 mm Hg

=

1,333 × 102 Pa

1 atmosphere

=

1,013 × 105 Pa

 
 

1 bar

=

105 Pa

 
 

The SI unit of temperature is the kelvin (K). The conversion of degrees Celsius to kelvin is according to the formula:

T = t + 273,15

where, T is the kelvin or thermodynamic temperature and t is the Celsius temperature.



Table 1

Measuring method

Substances

Estimated repeatability

Estimated reproducibility

Recommended range

Solid

Liquid

Dynamic method

Low melting

Yes

up to 25 %

1 to 5 %

up to 25 %

1 to 5 %

103 Pa to 2 × 103 Pa

2 × 103 Pa to 105 Pa

Static method

Yes

Yes

5 to 10 %

5 to 10 %

10 Pa to 105 Pa

10–2 Pa to 105 Pa (1)

Isoteniscope method

Yes

Yes

5 to 10 %

5 to 10 %

102 Pa to 105 Pa

Effusion method: vapour pressure balance

Yes

Yes

5 to 20 %

up to 50 %

10–3 to 1 Pa

Effusion method: Knudsen cell

Yes

Yes

10 to 30 %

10–10 to 1 P

Effusion method: isothermal thermogravimetry

Yes

Yes

5 to 30 %

up to 50 %

10–10 to 1 Pa

Gas saturation method

Yes

Yes

10 to 30 %

up to 50 %

10–10 to 103 Pa

Spinning rotor method

Yes

Yes

10 to 20 %

10–4 to 0,5 Pa

(1)   When using a capacitance manometer

1.3.   PRINCIPLE OF THE TEST

In general, the vapour pressure is determined at various temperatures. In a limited temperature range, the logarithm of the vapour pressure of a pure substance is a linear function of the inverse of the thermodynamic temperature according to the simplified Clapeyron-Clausius equation:

image

where:

p

=

the vapour pressure in pascals

ΔHv

=

the heat of vaporisation in J mol–1

R

=

the universal gas constant, 8,314 J mol–1 K–1

T

=

the temperature in K

1.4.   REFERENCE SUBSTANCES

Reference substances do not need to be employed. They serve primarily to check the performance of a method from time to time as well as to allow comparison between results of different methods.

1.5.   DESCRIPTION OF THE METHOD

1.5.1.   Dynamic method (Cottrell’s method)

1.5.1.1.   Principle

The vapour pressure is determined by measuring the boiling temperature of the substance at various specified pressures between roughly 103 and 105 Pa. This method is also recommended for the determination of the boiling temperature. For that purpose it is useful up to 600 K. The boiling temperatures of liquids are approximately 0,1 °C higher at a depth of 3 to 4 cm than at the surface because of the hydrostatic pressure of the column of liquid. In Cottrell’s method (4) the thermometer is placed in the vapour above the surface of the liquid and the boiling liquid is made to pump itself continuously over the bulb of the thermometer. A thin layer of liquid which is in equilibrium with vapour at atmospheric pressure covers the bulb. The thermometer thus reads the true boiling point, without errors due to superheating or hydrostatic pressure. The pump originally employed by Cottrell is shown in figure 1. Tube A contains the boiling liquid. A platinum wire B sealed into the bottom facilitates uniform boiling. The side tube C leads to a condenser, and the sheath D prevents the cold condensate from reaching the thermometer E. When the liquid in A is boiling, bubbles and liquid trapped by the funnel are poured via the two arms of the pump F over the bulb of the thermometer.



Figure 1image

Figure 2image

Cottrell pump (4)

A: Thermocouple

B: Vacuum buffer volume

C: Pressure gauge

D: Vacuum

E: Measuring point

F: Heating element c.a. 150 W

1.5.1.2.   Apparatus

A very accurate apparatus, employing the Cottrell principle, is shown in figure 2. It consists of a tube with a boiling section in the lower part, a cooler in the middle part, and an outlet and flange in the upper part. The Cottrell pump is placed in the boiling section which is heated by means of an electrical cartridge. The temperature is measured by a jacketed thermocouple, or resistance thermometer inserting through the flange at the top. The outlet is connected to the pressure regulation system. The latter consists of a vacuum pump, a buffer volume, a manostat for admitting nitrogen for pressure regulation and manometer.

1.5.1.3.   Procedure

The substance is placed in the boiling section. Problems may be encountered with non-powder solids but these can sometimes be solved by heating the cooling jacket. The apparatus is sealed at the flange and the substance degassed. Frothing substances cannot be measured using this method.

The lowest desired pressure is then set and the heating is switched on. At the same time, the temperature sensor is connected to a recorder.

Equilibrium is reached when a constant boiling temperature is recorded at constant pressure. Particular care must be taken to avoid bumping during boiling. In addition, complete condensation must occur on the cooler. When determining the vapour pressure of low melting solids, care should be taken to prevent the condenser from blocking.

After recording this equilibrium point, a higher pressure is set. The process is continued in this manner until 105 Pa has been reached (approximately 5 to 10 measuring points in all). As a check, equilibrium points must be repeated at decreasing pressures.

1.5.2.   Static method

1.5.2.1.   Principle

In the static method (5), the vapour pressure at thermodynamic equilibrium is determined at a specified temperature. This method is suitable for substances and multicomponent liquids and solids in the range from 10–1 to 105 Pa and, provided care is taken, also in the range 1 to 10 Pa.

1.5.2.2.   Apparatus

The equipment consists of a constant-temperature bath (precision of ± 0,2 K), a container for the sample connected to a vacuum line, a manometer and a system to regulate the pressure. The sample chamber (figure 3a) is connected to the vacuum line via a valve and a differential manometer (U-tube containing a suitable manometer fluid) which serves as zero indicator. Mercury, silicones and phthalates are suitable for use in the differential manometer, depending on the pressure range and the chemical behaviour of the test substance. However, based on environmental concerns, the use of mercury should be avoided, if possible. The test substance must not dissolve noticeably in, or react with, the U-tube fluid. A pressure gauge can be used instead of a U-tube (figure 3b). For the manometer, mercury can be used in the range from normal pressure down to 102 Pa, while silicone fluids and phthalates are suitable for use below 102 Pa down to 10 Pa. There are other pressure gauges which can be used below 102 Pa and heatable membrane capacity manometers can even be used at below 10–1 Pa. The temperature is measured on the outside wall of the vessel containing the sample or in the vessel itself.

1.5.2.3.   Procedure

Using the apparatus as described in figure 3a, fill the U-tube with the chosen liquid, which must be degassed at an elevated temperature before readings are taken. The test substance is placed in the apparatus and degassed at reduced temperature. In the case of a multiple-component sample, the temperature should be low enough to ensure that the composition of the material is not altered. Equilibrium can be established more quickly by stirring. The sample can be cooled with liquid nitrogen or dry ice, but care should be taken to avoid condensation of air or pump-fluid. With the valve over the sample vessel open, suction is applied for several minutes to remove the air. If necessary, the degassing operation is repeated several times.



Figure 3aimage

Figure 3bimage

When the sample is heated with the valve closed, the vapour pressure increases. This alters the equilibrium of the fluid in the U-tube. To compensate for this, nitrogen or air is admitted to the apparatus until the differential pressure indicator is at zero again. The pressure required for this can be read off the manometer or off an instrument of higher precision. This pressure corresponds to the vapour pressure of the substance at the temperature of the measurement. Using the apparatus described in figure 3b, the vapour pressure is read off directly.

The vapour pressure is determined at suitably small temperature intervals (approximately 5 to 10 measuring points in all) up to the desired temperature maximum.

Low-temperature readings must be repeated as a check. If the values obtained from the repeated readings do not coincide with the curve obtained for increasing temperature, this may be due to one of the following situations:

(i) the sample still contains air (e.g. in the case of highly viscous materials) or low-boiling substances which is or are released during heating;

(ii) the substance undergoes a chemical reaction in the temperature range investigated (e.g. decomposition, polymerisation).

1.5.3.   Isoteniscope Method

1.5.3.1.   Principle

The isoteniscope (6) is based on the principle of the static method. The method involves placing a sample in a bulb maintained at constant temperature and connected to a manometer and a vacuum pump. Impurities more volatile than the substance are removed by degassing at reduced pressure. The vapour pressure of the sample at selected temperatures is balanced by a known pressure of inert gas. The isoteniscope was developed to measure the vapour pressure of certain liquid hydrocarbons but it is appropriate for the investigation of solids as well. The method is usually not suitable for multicomponent systems. Results are subject to only slight errors for samples containing non-volatile impurities. The recommended range is 102 to 105 Pa.

1.5.3.2.   Apparatus

An example of a measuring device is shown in figure 4. A complete description can be found in ASTM D 2879-86 (6).

1.5.3.3.   Procedure

In the case of liquids, the substance itself serves as the fluid in the differential manometer. A quantity of the liquid, sufficient to fill the bulb and the short leg of the manometer, is put in the isoteniscope. The isoteniscope is attached to a vacuum system and evacuated, then filled by nitrogen. The evacuation and purge of the system is repeated twice to remove residual oxygen. The filled isoteniscope is placed in a horizontal position so that the sample spreads out into a thin layer in the sample bulb and manometer. The pressure of the system is reduced to 133 Pa and the sample is gently warmed until it just boils (removal of dissolved gases). The isoteniscope is then placed so that the sample returns to the bulb and fills the short leg of the manometer. The pressure is maintained at 133 Pa. The drawn-out tip of the sample bulb is heated with a small flame until the sample vapour released expands sufficiently to displace part of the sample from the upper part of the bulb and manometer arm into the manometer, creating a vapour-filled, nitrogen-free space. The isoteniscope is then placed in a constant temperature bath, and the pressure of the nitrogen is adjusted until it equals that of the sample. At the equilibrium, the pressure of the nitrogen equals the vapour pressure of the substance.

A: Pressure controlB: 8 mm OD TubeC: Dry nitrogen in pressure systemD: Sample vapourE: Small tipF: Liquid sample(Dimension in mm)

In the case of solids, and depending on the pressure and temperature ranges, manometer liquids such as silicon fluids or phthalates are used. The degassed manometer liquid is put in a bulge provided on the long arm of the isoteniscope. Then the solid to be investigated is placed in the sample bulb and is degassed at an elevated temperature. After that, the isoteniscope is inclined so that the manometer liquid can flow into the U-tube.

1.5.4.   Effusion method: vapour pressure balance (7)

1.5.4.1.   Principle

A sample of the test substance is heated in a small furnace and placed in an evacuated bell jar. The furnace is covered by a lid which carries small holes of known diameters. The vapour of the substance, escaping through one of the holes, is directed onto a balance pan of a highly sensitive balance which is also enclosed in the evacuated bell jar. In some designs the balance pan is surrounded by a refrigeration box, providing heat dissipation to the outside by thermal conduction, and is cooled by radiation so that the escaping vapour condenses on it. The momentum of the vapour jet acts as a force on the balance. The vapour pressure can be derived in two ways: directly from the force on the balance pan and also from the evaporation rate using the Hertz-Knudsen equation (2):

image

where:

G

=

evaporation rate (kg s–1 m–2)

M

=

molar mass (g mol–1)

T

=

temperature (K)

R

=

universal gas constant (J mol–1 K–1)

P

=

vapour pressure (Pa)

The recommended range is 10–3 to 1 Pa.

1.5.4.2.   Apparatus

The general principle of the apparatus is illustrated in figure 5.

image



A:

Base plate

F:

Refrigeration box and cooling bar

B:

Moving coil instrument

G:

Evaporator furnace

C:

Bell jar

H:

Dewar flask with liquid nitrogen

D:

Balance with scale pan

I:

Measurement of temperature of sample

E:

Vacuum measuring device

J:

Test Substance

1.5.5.   Effusion method: Knudsen cell

1.5.5.1.   Principle

The method is based on the estimation of the mass of test substance flowing out per unit of time of a Knudsen cell (8) in the form of vapour, through a micro-orifice under ultra-vacuum conditions. The mass of effused vapour can be obtained either by determining the loss of mass of the cell or by condensing the vapour at low temperature and determining the amount of volatilised substance using chromatography. The vapour pressure is calculated by applying the Hertz-Knudsen relation (see section 1.5.4.1) with correction factors that depend on parameters of the apparatus (9). The recommended range is 10–10 to 1 Pa (10)(11)(12)(13)(14).

1.5.5.2.   Apparatus

The general principle of the apparatus is illustrated in figure 6.

image



1:

Connection to vacuum

7:

Threaded lid

2:

Wells from platinum resistance thermometer or temperature measurement and control

8:

Butterfly nuts

3:

Lid for vacuum tank

9:

Bolts

4:

O-ring

10:

Stainless steel effusion cells

5:

Aluminum vacuum tank

11:

Heater cartridge

6:

Device for installing and removing the effusion cells

 
 

1.5.6.   Effusion method: isothermal thermogravimetry

1.5.6.1.   Principle

The method is based on the determination of accelerated evaporation rates for the test substance at elevated temperatures and ambient pressure using thermogravimetry (10)(15)(16)(17)(18)(19)(20). The evaporation rates vT result from exposing the selected compound to a slowly flowing inert gas atmosphere, and monitoring the weight loss at defined isothermal temperatures T in Kelvin over appropriate periods of time. The vapour pressures pT are calculated from the vT values by using the linear relationship between the logarithm of the vapour pressure and the logarithm of the evaporation rate. If necessary, an extrapolation to temperatures of 20 and 25 °C can be made by regression analysis of log pT vs. 1/T. This method is suitable for substances with vapour pressures as low as 10–10 Pa (10–12 mbar) and with purity as close as possible to 100 % to avoid the misinterpretation of measured weight losses.

1.5.6.2.   Apparatus

The general principle of the experimental set-up is shown in figure 7.

RotameterSuction pumpConstant flow rotameter with a multiple light barrier systemChart recorderSample carrier plateSorption unitAdjustable valveAdjustable valveMicro balanceN2 gasOvenN2 gas at ambient pressure

The sample carrier plate, hanging on a microbalance in a temperature controlled chamber, is swept by a stream of dry nitrogen gas which carries the vaporised molecules of the test substance away. After leaving the chamber, the gas stream is purified by a sorption unit.

1.5.6.3.   Procedure

The test substance is applied to the surface of a roughened glass plate as a homogeneous layer. In the case of solids, the plate is wetted uniformly by a solution of the substance in a suitable solvent and dried in an inert atmosphere. For the measurement, the coated plate is hung into the thermogravimetric analyser and subsequently its weight loss is measured continuously as a function of time.

The evaporation rate vT at a definite temperature is calculated from the weight loss Δm of the sample plate by

image

where F is the surface area of the coated test substances, normally the surface area of the sample plate, and t is the time for weight loss Δm.

The vapour pressure pT is calculated on the basis of its function of evaporation rate vT:

Log pT = C + D · log vT

where C and D are constants specific for the experimental arrangement used, depending on the diameter of the measurement chamber and on the gas flow rate. These constants must be determined once by measuring a set of compounds with known vapour pressure and regressing log pT vs. log vT (11)(21)(22).

The relationship between the vapour pressure pT and the temperature T in Kelvin is given by

Log pT = A + B · 1/T

where A and B are constants obtained by regressing log pT vs. 1/T. With this equation, the vapour pressure can be calculated for any other temperature by extrapolation.

1.5.7.   Gas saturation method (23)

1.5.7.1.   Principle

Inert gas is passed, at room temperature and at a known flow rate, through or over a sample of the test substance, slowly enough to ensure saturation. Achieving saturation in the gas phase is of critical importance. The transported substance is trapped, generally using a sorbent, and its amount is determined. As an alternative to vapour trapping and subsequent analysis, in-train analytical techniques, like gas chromatography, may be used to determine quantitatively the amount of material transported. The vapour pressure is calculated on the assumption that the ideal gas law is obeyed and that the total pressure of a mixture of gases is equal to the sum of the pressures of the component gases. The partial pressure of the test substance, i.e. the vapour pressure, is calculated from the known total gas volume and from the weight of the material transported.

The gas saturation procedure is applicable to solid or liquid substances. It can be used for vapour pressures down to 10–10 Pa (10)(11)(12)(13)(14). The method is most reliable for vapour pressures below 103 Pa. Above 103 Pa, the vapour pressures are generally overestimated, probably due to aerosol formation. Since the vapour pressure measurements are made at room temperature, the need to extrapolate data from high temperatures is not necessary and high temperature extrapolation, which can often cause serious errors, is avoided.

1.5.7.2.   Apparatus

The procedure requires the use of a constant-temperature box. The sketch in figure 8 shows a box containing three solid and three liquid sample holders, which allow for the triplicate analysis of either a solid or a liquid sample. The temperature is controlled to ± 0,5 °C or better.

Fine metering valveThree-way valveN2 inN2 outN2 out to flow meterCopper coil heat exchangerLiquid sample and sorbent holderSolid sample and sorbent holderFanLight bulbInsulated box

In general, nitrogen is used as an inert carrier gas but, occasionally, another gas may be required (24). The carrier gas must be dry. The gas stream is split into 6 streams, controlled by needle valves (approximately 0,79 mm orifice), and flows into the box via 3,8 mm i.d. copper tubing. After temperature equilibration, the gas flows through the sample and the sorbent trap and exists from the box.

Solid samples are loaded into 5 mm i.d. glass tubing between glass wool plugs (see Figure 9). Figure 10 shows a liquid sample holder and sorbent system. The most reproducible method for measuring the vapour pressure of liquids is to coat the liquid on glass beads or on an inert sorbent such as silica, and to pack the holder with these beads. As an alternative, the carrier gas may be made to pass a coarse frit and bubble through a column of the liquid test substance.



Figure 9image

Figure 10image

The sorbent system contains a front and a backup sorbent section. At very low vapour pressures, only small amounts are retained by the sorbent and the adsorption on the glass wool and the glass tubing between the sample and the sorbent may be a serious problem.

Traps cooled with solid CO2 are another efficient way for collecting the vaporised material. They do not cause any back pressure on the saturator column and it is also easy to quantitatively remove the trapped material.

1.5.7.3.   Procedure

The flow rate of the effluent carrier gas is measured at room temperature. The flow rate is checked frequently during the experiment to assure that there is an accurate value for the total volume of carrier gas. Continuous monitoring with a mass flow-meter is preferred. Saturation of the gas phase may require considerable contact time and hence quite low gas flow rates (25).

At the end of the experiment, both the front and backup sorbent sections are analysed separately. The compound on each section is desorbed by adding a solvent. The resulting solutions are analysed quantitatively to determine the weight desorbed from each section. The choice of the analytical method (also the choice of sorbent and desorbing solvent) is dictated by the nature of the test material. The desorption efficiency is determined by injecting a known amount of sample onto the sorbent, desorbing it and analysing the amount recovered. It is important to check the desorption efficiency at or near the concentration of the sample under the test conditions.

To assure that the carrier gas is saturated with the test substance, three different gas flow rates are used. If the calculated vapour pressure shows no dependence on flow rate, the gas is assumed to be saturated.

The vapour pressure is calculated through the equation:

image

where:

p

=

vapour pressure (Pa)

W

=

mass of evaporated test substance (g)

V

=

volume of saturated gas (m3)

R

=

universal gas constant 8,314 (J mol–1 K–1)

T

=

temperature (K)

M

=

molar mass of test substance (g mol–1)

Measured volumes must be corrected for pressure and temperature differences between the flow meter and the saturator.

1.5.8.   Spinning rotor

1.5.8.1.   Principle

This method uses a spinning rotor viscosity gauge, in which the measuring element is a small steel ball which, suspended in a magnetic field, is made to spin by rotating fields (26)(27)(28). Pick-up coils allow its spinning rate to be measured. When the ball has reached a given rotational speed, usually about 400 revolutions per second, energising is stopped and deceleration, due to gas friction, takes place. The drop of rotational speed is measured as a function of time. The vapour pressure is deduced from the pressure-dependent slow-down of the steel ball. The recommended range is 10–4 to 0,5 Pa.

1.5.8.2.   Apparatus

A schematic drawing of the experimental set-up is shown in figure 11. The measuring head is placed in a constant-temperature enclosure, regulated within 0,1 °C. The sample container is placed in a separate enclosure, also regulated within 0,1 °C. All other parts of the set-up are kept at a higher temperature to prevent condensation. The whole apparatus is connected to a high-vacuum system.

A: Spinning rotor sensor headB: Sampling cellC: ThermostatD: Vacuum line (turbo pump)E: Air thermostat

2.   DATA AND REPORTING

2.1.   DATA

The vapour pressure from any of the preceding methods should be determined for at least two temperatures. Three or more are preferred in the range from 0 to 50 °C, in order to check the linearity of the vapour pressure curve. In case of Effusion method (Knudsen cell and isothermal thermogravimetry) and Gas saturation method, 120 to 150 °C is recommended for the measuring temperature range instead of 0 to 50 °C.

2.2.   TEST REPORT

The test report must include the following information:

 method used,

 precise specification of the substance (identity and impurities) and preliminary purification step, if any,

 at least two vapour pressure and temperature values — and preferably three or more — required in the range from 0 to 50 °C (or 120 to 150 °C),

 at least one of the temperatures should be at or below 25 °C, if technically possible according to the chosen method,

 all original data,

 a log p versus 1/T curve,

 an estimate of the vapour pressure at 20 or 25 °C.

If a transition (change of state, decomposition) is observed, the following information should be noted:

 nature of the change,

 temperature at which the change occurs at atmospheric pressure,

 vapour pressure at 10 and 20 °C below the transition temperature and 10 and 20 °C above this temperature (unless the transition is from solid to gas).

All information and remarks relevant for the interpretation of results have to be reported, especially with regard to impurities and physical state of the substance.

3.   LITERATURE

(1)  Official Journal of the European Communities L 383 A, 26-47 (1992).

(2) Ambrose, D. (1975). Experimental Thermodynamics, Vol. II, Le Neindre, B., and Vodar, B., Eds., Butterworths, London.

(3) Weissberger R., ed. (1959). Technique of Organic Chemistry, Physical Methods of Organic Chemistry, 3rd ed., Vol. I, Part I. Chapter IX, Interscience Publ., New York.

(4) Glasstone, S. (1946). Textbook of Physical Chemistry, 2nd ed., Van Nostrand Company, New York.

(5) NF T 20-048 AFNOR (September 1985). Chemical products for industrial use — Determination of vapour pressure of solids and liquids within a range from 10–1 to 105 Pa — Static method.

(6) ASTM D 2879-86, Standard test method for vapour pressure — temperature relationship and initial decomposition temperature of liquids by isoteniscope.

(7) NF T 20-047 AFNOR (September 1985). Chemical products for industrial use — Determination of vapour pressure of solids and liquids within range from 10–3 to 1 Pa — Vapour pressure balance method.

(8) Knudsen, M. (1909). Ann. Phys. Lpz., 29, 1979; (1911), 34, 593.

(9) Ambrose, D., Lawrenson, I.J., Sprake, C.H.S. (1975). J. Chem. Thermodynamics 7, 1173.

(10) Schmuckler, M.E., Barefoot, A.C., Kleier, D.A., Cobranchi, D.P. (2000), Vapor pressures of sulfonylurea herbicides; Pest Management Science 56, 521-532.

(11) Tomlin, C.D.S. (ed.), The Pesticide Manual, Twelfth Edition (2000).

(12) Friedrich, K., Stammbach, K., Gas chromatographic determination of small vapour pressures determination of the vapour pressures of some triazine herbicides. J. Chromatog. 16 (1964), 22-28.

(13) Grayson, B.T., Fosbraey, L.A., Pesticide Science 16 (1982), 269-278.

(14) Rordorf, B.F., Prediction of vapor pressures, boiling points and enthalpies of fusion for twenty-nine halogenated dibenzo-p-dioxins, Thermochimia Acta 112 Issue 1 (1987), 117-122.

(15) Gückel, W., Synnatschke, G., Ritttig, R., A Method for Determining the Volatility of Active Ingredients Used in Plant Protection; Pesticide Science 4 (1973) 137-147.

(16) Gückel, W., Synnatschke, G., Ritttig, R., A Method for Determining the Volatility of Active Ingredients Used in Plant Protection II. Application to Formulated Products; Pesticide Science 5 (1974) 393-400.

(17) Gückel, W., Kaestel, R., Lewerenz, J., Synnatschke, G., A Method for Determining the Volatility of Active Ingredients Used in Plant Protection. Part III: The Temperature Relationship between Vapour Pressure and Evaporation Rate; Pesticide Science 13 (1982) 161-168.

(18) Gückel, W., Kaestel, R., Kroehl, T., Parg, A., Methods for Determining the Vapour Pressure of Active Ingredients Used in Crop Protection. Part IV: An Improved Thermogravimetric Determination Based on Evaporation Rate; Pesticide Science 45 (1995) 27-31.

(19) Kroehl, T., Kaestel, R., Koenig, W., Ziegler, H., Koehle, H., Parg, A., Methods for Determining the Vapour Pressure of Active Ingredients Used in Crop Protection. Part V: Thermogravimetry Combined with Solid Phase MicroExtraction (SPME); Pesticide Science, 53 (1998) 300-310.

(20) Tesconi, M., Yalkowsky, S.H., A Novel Thermogravimetric Method for Estimating the Saturated Vapor Pressure of Low-Volatility Compounds; Journal of Pharmaceutical Science 87(12) (1998) 1512-20.

(21) Lide, D.R. (ed.), CRC Handbook of Chemistry and Physics, 81st ed. (2000), Vapour Pressure in the Range — 25 °C to 150 °C.

(22) Meister, R.T. (ed.), Farm Chemicals Handbook, Vol. 88 (2002).

(23) 40 CFR, 796. (1993). pp 148-153, Office of the Federal Register, Washington DC.

(24) Rordorf B.F. (1985). Thermochimica Acta 85, 435.

(25) Westcott et al. (1981). Environ. Sci. Technol. 15, 1375.

(26) Messer G., Röhl, P., Grosse G., and Jitschin W. (1987). J. Vac. Sci. Technol. (A), 5(4), 2440.

(27) Comsa G., Fremerey J.K., and Lindenau, B. (1980). J. Vac. Sci. Technol. 17(2), 642.

(28) Fremerey, J.K. (1985). J. Vac. Sci. Technol. (A), 3(3), 1715.

Appendix

Estimation method

INTRODUCTION

Estimated values of the vapour pressure can be used:

 for deciding which of the experimental methods is appropriate,

 for providing an estimate or limit value in cases where the experimental method cannot be applied due to technical reasons.

ESTIMATION METHOD

The vapour pressure of liquids and solids can be estimated by use of the modified Watson correlation (a). The only experimental data required is the normal boiling point. The method is applicable over the pressure range from 105 Pa to 10–5 Pa.

Detailed information on the method is given in ‘Handbook of Chemical Property Estimation Methods’ (b). See also OECD Environmental Monograph No.67 (c).

CALCULATION PROCEDURE

The vapour pressure is calculated as follows:

image

where:

T

=

temperature of interest

Tb

=

normal boiling point

Pvp

=

vapour pressure at temperature T

ΔHvb

=

heat of vaporisation

ΔZb

=

compressibility factor (estimated at 0,97)

m

=

empirical factor depending on the physical state at the temperature of interest

Further,

image

where, KF is an empirical factor considering the polarity of the substance. For several compound types, KF factors are listed in reference (b).

Quite often, data are available in which a boiling point at reduced pressure is given. In such a case, the vapour pressure is calculated as follows:

image

where, T1 is the boiling point at the reduced pressure P1.

REPORT

When using the estimation method, the report shall include a comprehensive documentation of the calculation.

LITERATURE

(a) Watson, K.M. (1943). Ind. Eng. Chem, 35, 398.

(b) Lyman, W.J., Reehl, W.F., Rosenblatt, D.H. (1982). Handbook of Chemical Property Estimation Methods, McGraw-Hill.

(c) OECD Environmental Monograph No.67. Application of Structure-Activity Relationships to the Estimation of Properties Important in Exposure Assessment (1993).

▼B

A.5.   SURFACE TENSION

1.   METHOD

The methods described are based on the OECD Test Guideline (1). The fundamental principles are given in reference (2).

1.1.   INTRODUCTION

The described methods are to be applied to the measurement of the surface tension of aqueous solutions.

It is useful to have preliminary information on the water solubility, the structure, the hydrolysis properties and the critical concentration for micelles formation of the substance before performing these tests.

The following methods are applicable to most chemical substances, without any restriction in respect to their degree of purity.

The measurement of the surface tension by the ring tensiometer method is restricted to aqueous solutions with a dynamic viscosity of less than approximately 200 mPa s.

1.2.   DEFINITIONS AND UNITS

The free surface enthalpy per unit of surface area is referred to as surface tension.

The surface tension is given as:

N/m (SI unit) or

mN/m (SI sub-unit)

1 N/m = 103 dynes/cm

1 mN/m = 1 dyne/cm in the obsolete cgs system

1.3.   REFERENCE SUBSTANCES

Reference substances do not need to be employed in all cases when investigating a new substance. They should primarily serve to check the performance of the method from time to time and to allow comparison with results from other methods.

Reference substances which cover a wide range of surface tensions are given in references 1 and 3.

1.4.   PRINCIPLE OF THE METHODS

The methods are based on the measurement of the maximum force which is necessary to exert vertically, on a stirrup or a ring in contact with the surface of the liquid being examined placed in a measuring cup, in order to separate it from this surface, or on a plate, with an edge in contact with the surface, in order to draw up the film that has formed.

Substances which are soluble in water at least at a concentration of 1 mg/l are tested in aqueous solution at a single concentration.

1.5.   QUALITY CRITERIA

These methods are capable of greater precision than is likely to be required for environmental assessment.

1.6.   DESCRIPTION OF THE METHODS

A solution of the substance is prepared in distilled water. The concentration of this solution should be 90 % of the saturation solubility of the substance in water; when this concentration exceeds 1 g/l, a concentration of 1 g/l is used for testing. Substances with water solubility lower than 1 mg/l need not be tested.

1.6.1.   Plate method

See ISO 304 and NF T 73-060 (Surface active agents — determination of surface tension by drawing up liquid films).

1.6.2.   Stirrup method

See ISO 304 and NF T 73-060 (Surface active agents — determination of surface tension by drawing up liquid films).

1.6.3.   Ring method

See ISO 304 and NF T 73-060 (Surface active agents — determination of surface tension by drawing up liquid films).

1.6.4.   OECD harmonised ring method

1.6.4.1.   Apparatus

Commercially available tensiometers are adequate for this measurement. They consist of the following elements:

 mobile sample table,

 force measuring system,

 measuring body (ring),

 measurement vessel.

1.6.4.1.1.    Mobile sample table

The mobile sample table is used as a support for the temperature-controlled measurement vessel holding the liquid to be tested. Together with the force measuring system, it is mounted on a stand.

1.6.4.1.2.    Force measuring system

The force measuring system (see figure) is located above the sample table. The error of the force measurement shall not exceed ± 10-6 N, corresponding to an error limit of ± 0,1 mg in a mass measurement. In most cases, the measuring scale of commercially available tensiometers is calibrated in mN/m so that the surface tension can be read directly in mN/m with an accuracy of 0,1 mN/m.

1.6.4.1.3.    Measuring body (ring)

The ring is usually made of a platinum-iridium wire of about 0,4 mm thickness and a mean circumference of 60 mm. The wire ring is suspended horizontally from a metal pin and a wire mounting bracket to establish the connection to the force measuring system (see figure).

(All dimensions expressed in millimetres)

Mounting bracketPinRing

1.6.4.1.4.    Measurement vessel

The measurement vessel holding the test solution to be measured shall be a temperature-controlled glass vessel. It shall be designed so that during the measurement the temperature of the test solution liquid and the gas phase above its surface remains constant and that the sample cannot evaporate. Cylindrical glass vessels having an inside diameter of not less than 45 mm are acceptable.

1.6.4.2.   Preparation of the apparatus

1.6.4.2.1.    Cleaning

Glass vessels shall be cleaned carefully. If necessary they shall be washed with hot chromo-sulphuric acid and subsequently with syrupy phosphoric acid (83 to 98 % by weight of H3PO4), thoroughly rinsed in tap water and finally washed with double-distilled water until a neutral reaction is obtained and subsequently dried or rinsed with part of the sample liquid to be measured.

The ring shall first be rinsed thoroughly in water to remove any substances which are soluble in water, briefly immersed in chromo-sulphuric acid, washed in double-distilled water until a neutral reaction is obtained and finally heated briefly above a methanol flame.

Note:

Contamination by substances which are not dissolved or destroyed by chromo-sulphuric acid or phosphoric acid, such as silicones, shall be removed by means of a suitable organic solvent.

1.6.4.2.2.    Calibration of the apparatus

The validation of the apparatus consists of verifying the zero point and adjusting it so that the indication of the instrument allows reliable determination in mN/m.

The apparatus shall be levelled, for instance by means of a spirit level on the tensiometer base, by adjusting the levelling screws in the base.

After mounting the ring on the apparatus and prior to immersion in the liquid, the tensiometer indication shall be adjusted to zero and the ring checked for parallelism to the liquid surface. For this purpose, the liquid surface can be used as a mirror.

The actual test calibration can be accomplished by means of either of two procedures:

(a) Using a mass: procedure using riders of known mass between 0,1 and 1,0 g placed on the ring. The calibration factor, Φa by which all the instrument readings must be multiplied, shall be determined according to equation (1).



image

 

where:

image

(mN/m)

m

=

mass of the rider (g)

g

=

gravity acceleration (981 cm s-2 at sea level)

b

=

mean circumference of the ring (cm)

σa

=

reading of the tensiometer after placing the rider on the ring (mN/m).

(b) Using water: procedure using pure water whose surface tension at, for instance, 23 oC is equal to 72,3 mN/m. This procedure is accomplished faster than the weight calibration but there is always the danger that the surface tension of the water is falsified by traces of contamination by surfactants.

The calibration factor, Φb by which all the instrument readings shall be multiplied, shall be determined in accordance with the equation (2):



image

 

where:

σo

=

value cited in the literature for the surface tension of water (mN/m)

σg

=

measured value of the surface tension of the water (mN/m) both at the same temperature.

1.6.4.3.   Preparation of samples

Aqueous solutions shall be prepared of the substances to be tested, using the required concentrations in water, and shall not contain any non-dissolved substances.

The solution must be maintained at a constant temperature (± 0,5oC). Since the surface tension of a solution in the measurement vessel alters over a period of time, several measurements shall be made at various times and a curve plotted showing surface tension as a function of time. When no further change occurs, a state of equilibrium has been reached.

Dust and gaseous contamination by other substances interfere with the measurement. The work shall therefore be carried out under a protective cover.

1.6.5.   Test conditions

The measurement shall be made at approximately 20 oC and shall be controlled to within ± 0,5oC.

1.6.6.   Performance of test

The solutions to be measured shall be transferred to the carefully cleaned measurement vessel, taking care to avoid foaming, and subsequently the measurement vessel shall be placed onto the table of the test apparatus. The table-top with measurement vessel shall be raised until the ring is immersed below the surface of the solution to be measured. Subsequently, the table-top shall be lowered gradually and evenly (at a rate of approximately 0,5 cm/min) to detach the ring from the surface until the maximum force has been reached. The liquid layer attached to the ring must not separate from the ring. After completing the measurements, the ring shall be immersed below the surface again and the measurements repeated until a constant surface tension value is reached. The time from transferring the solution to the measurement vessel shall be recorded for each determination. Readings shall be taken at the maximum force required to detach the ring from the liquid surface.

2.   DATA

In order to calculate the surface tension, the value read in mN/m on the apparatus shall be first multiplied by the calibration factor Φa or Φb (depending on the calibration procedure used). This will yield a value which applies only approximately and therefore requires correction.

Harkins and Jordan (4) have empirically determined correction factors for surface-tension values measured by the ring method which are dependent on ring dimensions, the density of the liquid and its surface tension.

Since it is laborious to determine the correction factor for each individual measurement from the Harkins and Jordan tables, in order to calculate the surface tension for aqueous solutions the simplified procedure of reading the corrected surface-tension values directly from the table may be used. (Interpolation shall be used for readings ranging between the tabular values.)



Table:

Correction of the measured surface tension

Only for aqueous solutions, ρ = 1 g/cm3

r

= 9,55 mm (average ring radius)

r

= 0,185 mm (ring wire radius)



Experimental Value (mN/m)

Corrected Value (mN/m)

Weight calibration (see 1.6.4.2.2(a))

Water calibration (see 1.6.4.2.2(b))

20

16,9

18,1

22

18,7

20,1

24

20,6

22,1

26

22,4

24,1

28

24,3

26,1

30

26,2

28,1

32

28,1

30,1

34

29,9

32,1

36

31,8

34,1

38

33,7

36,1

40

35,6

38,2

42

37,6

40,3

44

39,5

42,3

46

41,4

44,4

48

43,4

46,5

50

45,3

48,6

52

47,3

50,7

54

49,3

52,8

56

51,2

54,9

58

53,2

57,0

60

55,2

59,1

62

57,2

61,3

64

59,2

63,4

66

61,2

65,5

68

63,2

67,7

70

65,2

69,9

72

67,2

72,0

74

69,2

76

71,2

78

73,2

This table has been compiled on the basis of the Harkins-Jordan correction. It is similar to that in the DIN Standard (DIN 53914) for water and aqueous solutions (density ρ = 1 g/cm3 and is for a commercially available ring having the dimensions R = 9,55 mm (mean ring radius) and r = 0,185 mm (ring wire radius). The table provides corrected values for surface-tension measurements taken after calibration with weights or calibration with water.

Alternatively, without the preceding calibration, the surface tension call can be calculated according to the following formula:

image

where:

F

=

the force measured on the dynamometer at the breakpoint of the film

R

=

the radius of the ring

f

=

the correction factor (1)

3.   REPORTING

3.1.   TEST REPORT

The test report shall, if possible, include the following information:

 method used,

 type of water or solution used,

 precise specification of the substance (identity and impurities),

 measurement results: surface tension (reading) stating both the individual readings and their arithmetic mean as well as the corrected mean (taking into consideration the equipment factor and the correction table),

 concentration of the solution,

 test temperature,

 age of solution used; in particular the time between preparation and measurement of the solution,

 description of time dependence of surface tension after transferring the solution to the measurement vessel,

 all information and remarks relevant for the interpretation of results have to be reported, especially with regard to impurities and physical state of the substance.

3.2.   INTERPRETATION OF RESULTS

Considering that distilled water has a surface tension of 72,75 mN/m at 20 oC, substances showing a surface tension lower than 60 mN/m under the conditions of this method should be regarded as being surface-active materials.

4.   REFERENCES

(1) OECD, Paris, 1981, Test Guideline 115, Decision of the Council C(81) 30 final.

(2) R. Weissberger ed.: Technique of Organic Chemistry, Physical Methods of Organic Chemistry, 3rd ed., Interscience Publ., New York, 1959, vol. I, Part I, Chapter XIV.

(3) Pure Appl. Chem., 1976, vol. 48, p. 511.

(4) Harkins, W.D., Jordan, H.F., J. Amer. Chem. Soc., 1930, vol. 52, p. 1751.

A.6.   WATER SOLUBILITY

1.   METHOD

The methods described are based on the OECD Test Guideline (1).

1.1.   INTRODUCTION

It is useful to have preliminary information on the structural formula, the vapour pressure, the dissociation constant and the hydrolysis (as a function of pH) of the substance to perform this test.

No single method is available to cover the whole range of solubilities in water.

The two test methods described below cover the whole range of solubilities but are not applicable to volatile substances:

 one which applies to essentially pure substances with low solubilities, (< 10-2 grams per litre), and which are stable in water, referred to as the ‘column elution method’,

 the other which applies to essentially pure substances with higher solubilities (> 10-2 grams per litre), and which are stable in water, referred to as the ‘flask method’.

The water solubility of the test substance can be considerably affected by the presence of impurities.

1.2.   DEFINITION AND UNITS

The solubility in water of a substance is specified by the saturation mass concentration of the substance in water at a given temperature. The solubility in water is specified in units of mass per volume of solution. The SI unit is kg/m3 (grams per litre may also be used).

1.3.   REFERENCE SUBSTANCES

Reference substances do not need to be employed in all cases when investigating a new substance. They should primarily serve to check the performance of the method from time to time and to allow comparison with results from other methods.

1.4.   PRINCIPLE OF THE TEST METHOD

The approximate amount of the sample and the time necessary to achieve the saturation mass concentration should be determined in a simple preliminary test.

1.4.1.   Column elution method

This method is based on the elution of a test substance with water from a micro-column which is charged with an inert support material, such as glass beads or sand, coated with an excess of test substance. The water solubility is determined when the mass concentration of the eluate is constant. This is shown by a concentration plateau as a function of time.

1.4.2.   Flask method

In this method, the substance (solids must be pulverised) is dissolved in water at a temperature somewhat above the test temperature. When saturation is achieved the mixture is cooled and kept at the test temperature, stirring as long as necessary to reach equilibrium. Alternatively, the measurement can be performed directly at the test temperature, if it is assured by appropriate sampling that the saturation equilibrium is reached. Subsequently, the mass concentration of the substance in the aqueous solution, which must not contain any undissolved particles, is determined by a suitable analytical method.

1.5.   QUALITY CRITERIA

1.5.1.   Repeatability

For the column elution method, < 30 % may be obtainable; for the flask method, < 15 % should be observed.

1.5.2.   Sensitivity

This depends upon the method of analysis, but mass concentration determinations down to 10-6 grams per litre can be determined.

1.6.   DESCRIPTION OF THE METHOD

1.6.1.   Test conditions

The test is preferably run at 20 ± 0,5oC. If a temperature dependence is suspected in the solubility (> 3 % per oC), two other temperatures at least 10 oC above and below the initially chosen temperature should also be used. In this case, the temperature control should be ± 0,1oC. The chosen temperature should be kept constant in all relevant parts of the equipment.

1.6.2.   Preliminary test

To approximately 0,1 g of the sample (solid substances must be pulverised) in a glass-stoppered 10 ml graduated cylinder, increasing volumes of distilled water at room temperature are added according to the steps shown in the table below:



0,1 g soluble in ‘x’ ml of water

0,1

0,5

1

2

10

100

> 100

Approximative solubility (grams per litre)

> 1 000

1 000 to 200

200 to 100

100 to 50

50 to 10

10 to 1

< 1

After each addition of the indicated amount of water, the mixture is shaken vigorously for 10 minutes and is visually checked for any undissolved parts of the sample. If, after addition of 10 ml of water, the sample or parts of it remain undissolved, the experiment has to be repeated in a 100 ml measuring cylinder with larger volumes of water. At lower solubilities the time required to dissolve a substance can be considerably longer (at least 24 h should be allowed). The approximate solubility is given in the table under that volume of added water in which complete dissolution of the sample occurs. If the substance is still apparently insoluble, more than 24 h should be allowed (96 h maximum), or further dilution should be undertaken to ascertain whether the column elution or flask solubility method should be used.

1.6.3.   Column elution method

1.6.3.1.   Support material, solvent and eluent

The support material for the column elution method should be inert. Possible materials which can be employed are glass beads and sand. A suitable volatile solvent of analytical reagent quality should be used to apply the test substance to the support material. Water which has been double distilled in glass or quartz apparatus should be employed as the eluent.

Note:

Water directly from an organic ion exchanger must not be used.

1.6.3.2.   Loading of the support

Approximately 600 mg of support material is weighed and transferred to a 50 ml round-bottom flask.

A suitable, weighed amount of test substance is dissolved in the chosen solvent. An appropriate amount of this solution is added to the support material. The solvent must be completely evaporated, e.g. in a rotary evaporator; otherwise water saturation of the support is not achieved due to partition effects on the surface of the support material.

The loading of support material may cause problems (erroneous results) if the test substance is deposited as an oil or a different crystal phase. The problem should be examined experimentally and the details reported.

The loaded support material is allowed to soak for about two hours in approximately 5 ml of water, and then the suspension is added to the microcolumn. Alternatively, dry loaded support material may be poured into the microcolumn, which has been filled with water, and then equilibrated for approximately two hours.

The elution of the substance from the support material can be carried out in one of two different ways:

 recirculating pump (see figure 1),

 levelling vessel (see figure 4).

1.6.3.3.   Column elution method with recirculating pump

A schematic arrangement of a typical system is presented in figure 1. A suitable microcolumn is shown in figure 2, although any size is acceptable, provided it meets the criteria for reproducibility and sensitivity. The column should provide for a headspace of at least five bed volumes of water and be able to hold a minimum of five samples. Alternatively, the size can be reduced if make-up solvent is employed to replace the initial five bed volumes removed with impurities.

The column should be connected to a recirculating pump capable of controlling flows of approximately 25 ml/h. The pump is connected with polytetrafluoroethylene (P.T.F.E.) and/or glass connections. The column and pump, when assembled, should have provision for sampling the effluent and equilibrating the headspace at atmospheric pressure. The column material is supported with a small (5 mm) plug of glass wool, which also serves to filter out particles. The recirculating pump can be, for example, a peristaltic pump or a membrane pump (care must be taken that no contamination and/or absorption occurs with the tube material).

The flow through the column is started. It is recommended that a flow rate of approximately 25 ml/hr be used (this corresponds to 10 bed volumes/hr for the column described). The first five bed volumes (minimum) are discarded to remove water-soluble impurities. Following this, the recirculating pump is allowed to run until equilibration is established, as defined by five successive samples whose concentrations do not differ by more than ± 30 % in a random fashion. These samples should be separated from each other by time intervals corresponding to the passage of at least 10 bed volumes of the eluent.

1.6.3.4.   Column elution method with levelling vessel

Levelling vessel: the connection to the levelling vessel is made by using a ground glass joint which is connected by PTFE tubing. It is recommended that a flow rate of approximately 25 ml/hr be used. Successive eluate fractions should be collected and analysed by the chosen method.

Those fractions from the middle eluate range where the concentrations are constant (± 30 %) in at least five consecutive fractions are used to determine the solubility in water.

In both cases (using a recirculating pump or a levelling vessel), a second run is to be performed at half the flow rate of the first. If the results of the two runs are in agreement, the test is satisfactory; if there is a higher apparent solubility with the lower flow rate, then the halving of the flow rate must continue until two successive runs give the same solubility.

In both cases (using a recirculating pump or a levelling vessel) the fractions should be checked for the presence of colloidal matter by examination for the Tyndall effect (light scattering). Presence of such particles invalidates the results, and the test should be repeated with improvements in the filtering action of the column.

The pH of each sample should be recorded. A second run should be performed at the same temperature.

1.6.4.   Flask method

1.6.4.1.   Apparatus

For the flask method the following material is needed:

 normal laboratory glassware and instrumentation,

 a device suitable for the agitation of solutions under controlled constant temperatures,

 a centrifuge (preferably thermostated), if required with emulsions, and

 equipment for analytical determination.

1.6.4.2.   Measurement procedure

The quantity of material necessary to saturate the desired volume of water is estimated from the preliminary test. The volume of water required will depend on the analytical method and the solubility range. About five times the quantity of material determined above is weighed into each of three glass vessels fitted with glass stoppers (e.g. centrifuge tubes, flasks). The chosen volume of water is added to each vessel, and the vessels are tightly stoppered. The closed vessels are then agitated at 30 oC. (A shaking or stirring device capable of operating at constant temperature should be used, e.g. magnetic stirring in a thermostatically controlled water bath). After one day, one of the vessels is removed and re-equilibrated for 24 hours at the test temperature with occasional shaking. The contents of the vessel are then centrifuged at the test temperature, and the concentration of test substance in the clear aqueous phase is determined by a suitable analytical method. The other two flasks are treated similarly after initial equilibration at 30 oC for two and three days, respectively. If the concentration results from at least the last two vessels agree with the required reproducibility, the test is satisfactory. The whole test should be repeated, using longer equilibration times, if the results from vessels 1, 2 and 3 show a tendency to increasing values.

The measurement procedure can also be performed without pre-incubation at 30 oC. In order to estimate the rate of establishment of the saturation equilibrium, samples are taken until the stirring time no longer influences the concentration of the test solution.

The pH of each sample should be recorded.

1.6.5.   Analysis

A substance-specific analytical method is preferred for these determinations, since small amounts of soluble impurities can cause large errors in the measured solubility. Examples of such methods are: gas or liquid chromatography, titration methods, photometric methods, voltammetric methods.

2.   DATA

2.1.   COLUMN ELUTION METHOD

The mean value from at least five consecutive samples taken from the saturation plateau should be calculated for each run, as should the standard deviation. The results should be given in units of mass per volume of solution.

The means calculated on two tests using different flows are compared and should have a repeatability of less than 30 %.

2.2.   FLASK METHOD

The individual results should be given for each of the three flasks and those results deemed to be constant (repeatability of less than 15 %) should be averaged and given in units of mass per volume of solution. This may require the reconversion of mass units to volume units, using the density when the solubility is very high (> 100 grams per litre).

3.   REPORTING

3.1.   COLUMN ELUTION METHOD

The test report shall, if possible, include the following information:

 the results of the preliminary test,

 precise specification of the substance (identity and impurities),

 the individual concentrations, flow rates and pH of each sample,

 the means and standard deviations from at least five samples from the saturation plateau of each run,

 the average of the two successive, acceptable runs,

 the temperature of the water during the saturation process,

 the method of analysis employed,

 the nature of the support material employed,

 loading of support material,

 solvent used,

 evidence of any chemical instability of the substance during the test and the method used,

 all information relevant for the interpretation of the results, especially with regard to impurities and physical state of the substance.

3.2.   FLASK METHOD

The test report shall, if possible, include the following information:

 the results of the preliminary test,

 precise specification of the substance (identity and impurities),

 the individual analytical determinations and the average where more than one value was determined for each flask,

 the pH of each sample,

 the average of the value for the different flasks which were in agreement,

 the test temperature,

 the analytical method employed,

 evidence of any chemical instability of the substance during the test and the method used,

 all information relevant for the interpretation of the results, especially with regard to impurities and physical state of the substance.

4.   REFERENCES

(1) OECD, Paris, 1981, Test Guideline 105, Decision of the Council C(81) 30 final.

(2) NF T 20-045 (AFNOR) (September 85) Chemical products for industrial use — Determination of water solubility of solids and liquids with low solubility — Column elution method.

(3) NF T 20-046 (AFNOR) (September 85) Chemical products for industrial use — Determination of water solubility of solids and liquids with high solubility — Flask method.

Appendix

Figure 1

Column elution method with recirculating pump

Atmospheric equilibrationFlow meterMicrocolumnThermostatically controlled circulating pumpRecirculating pumpTwo-way valve for sampling

Figure 2

A typical microcolumn

(All dimensions in millimetres)

(Connection for ground glass joint)HeadspaceInterior 5Exterior 19Plug of glass woolStopcock with two-way action

Figure 3

A typical microcolumn

(All dimensions in millimetres)

Connection for ground glass jointHeadspaceInterior 5Exterior 19Stopcock

Figure 4

Column elution method with levelling vessel

1 = Levelling vessel (e.g. 2,5 litre flask)2 = Column (see figure 3)3 = Fraction collector4 = Thermostat5 = Teflon tubing6 = Ground glass joint7 = Water line (between thermostat and column, inner diameter: approximately 8 mm)

A.8.   PARTITION COEFFICIENT

1.   METHOD

The ‘shake flask’ method described is based on the OECD Test Guideline (1).

1.1.   INTRODUCTION

It is useful to have preliminary information on structural formula, dissociation constant, water solubility, hydrolysis, n-octanol solubility and surface tension of the substance to perform this test.

Measurements should be made on ionisable substances only in their non-ionised form (free acid or free base) produced by the use of an appropriate buffer with a pH of at least one pH unit below (free acid) or above (free base) the pK.

This test method includes two separate procedures: the shake flask method and high performance liquid chromatography (HPLC). The former is applicable when the log Pow value (see below for definitions) falls within the range - 2 to 4 and the latter within the range 0 to 6. Before carrying out either of the experimental procedures a preliminary estimate of the partition coefficient should first be obtained.

The shake-flask method applies only to essentially pure substances soluble in water and n-octanol. It is not applicable to surface active materials (for which a calculated value or an estimate based on the individual n-octanol and water solubilities should be provided).

The HPLC method is not applicable to strong acids and bases, metal complexes, surface-active materials or substances which react with the eluent. For these materials, a calculated value or an estimate based on individual n-octanol and water solubilities should be provided.

The HPLC method is less sensitive to the presence of impurities in the test compound than is the shake-flask method. Nevertheless, in some cases impurities can make the interpretation of the results difficult because peak assignment becomes uncertain. For mixtures which give an unresolved band, upper and lower limits of log P should be stated.

1.2.   DEFINITION AND UNITS

The partition coefficient (P) is defined as the ratio of the equilibrium concentrations (ci) of a dissolved substance in a two-phase system consisting of two largely immiscible solvents. In the case n-octanol and water:

image

The partition coefficient (P) therefore is the quotient of two concentrations and is usually given in the form of its logarithm to base 10 (log P).

1.3.   REFERENCE SUBSTANCES

Shake-flask method

Reference substances do not need to be employed in all cases when investigating a new substance. They should primarily serve to check the performance of the method from time to time and to allow comparison with results from other methods.

HPLC method

In order to correlate the measured HPLC data of a compound with its P value, a calibration graph of log P versus chromatographic data using at least six reference points has to be established. It is for the user to select the appropriate reference substances. Whenever possible, at least one reference compound should have a Pow above that of the test substance, and another a Pow below that of the test substance. For log P values less than 4, the calibration can be based on data obtained by the shake-flask method. For log P values greater than 4, the calibration can be based on validated literature values if these are in agreement with calculated values. For better accuracy, it is preferable to choose reference compounds which are structurally related to the test substance.

Extensive lists of values of log Pow for many groups of chemicals are available (2)(3). If data on the partition coefficients of structurally related compounds are not available, then a more general calibration, established with other reference compounds, may be used.

A list of recommended reference substances and their Pow values is given in Appendix 2.

1.4.   PRINCIPLE OF THE METHOD

1.4.1.   Shake-flask method

In order to determine a partition coefficient, equilibrium between all interacting components of the system must be achieved, and the concentrations of the substances dissolved in the two phases must be determined. A study of the literature on this subject indicates that several different techniques can be used to solve this problem, i.e. the thorough mixing of the two phases followed by their separation in order to determine the equilibrium concentration for the substance being examined.

1.4.2.   HPLC method

HPLC is performed on analytical columns packed with a commercially available solid phase containing long hydrocarbon chains (e.g. C8, C18) chemically bound onto silica. Chemicals injected onto such a column move along it at different rates because of the different degrees of partitioning between the mobile phase and the hydrocarbon stationary phase. Mixtures of chemicals are eluted in order of their hydrophobicity, with water-soluble chemicals eluted first and oil-soluble chemicals last, in proportion to their hydrocarbon-water partition coefficient. This enables the relationship between the retention time on such a (reverse phase) column and the n-octanol/water partition coefficient to be established. The partition coefficient is deduced from the capacity factor k, given by the expression:

image

in which, tr = retention time of the test substance, and to = average time a solvent molecule needs to pass through the column (dead-time).

Quantitative analytical methods are not required and only the determination of elution times is necessary.

1.5.   QUALITY CRITERIA

1.5.1.   Repeatability

In order to assure the accuracy of the partition coefficient, duplicate determinations are to be made under three different test conditions, whereby the quantity of substance specified as well as the ratio of the solvent volumes may be varied. The determined values of the partition coefficient expressed as their common logarithms should fall within a range of ± 0,3 log units.

In order to increase the confidence in the measurement, duplicate determinations must be made. The values of log P derived from individual measurements should fall within a range of ± 0,1 log units.

1.5.2.   Sensitivity

The measuring range of the method is determined by the limit of detection of the analytical procedure. This should permit the assessment of values of log Pow in the range of - 2 to 4 (occasionally when conditions apply, this range may be extended to log Pow up to 5) when the concentration of the solute in either phase is not more than 0,01 mol per litre.

The HPLC method enables partition coefficients to be estimated in the log Pow range 0 to 6.

Normally, the partition coefficient of a compound can be estimated to within ± l log unit of the shake-flask value. Typical correlations can be found in the literature (4)(5)(6)(7)(8). Higher accuracy can usually be achieved when correlation plots are based on structurally-related reference compounds (9).

1.5.3.   Specificity

The Nernst Partition Law applies only at constant temperature, pressure and pH for dilute solutions. It strictly applies to a pure substance dispersed between two pure solvents. If several different solutes occur in one or both phases at the same time, this may affect the results.

Dissociation or association of the dissolved molecules result in deviations from the Nernst Partition Law. Such deviations are indicated by the fact that the partition coefficient becomes dependent upon the concentration of the solution.

Because of the multiple equilibria involved, this test method should not be applied to ionisable compounds without applying a correction. The use of buffer solutions in place of water should be considered for such compounds; the pH of the buffer should be at least 1 pH unit from the pKa of the substance and bearing in mind the relevance of this pH for the environment.

1.6.   DESCRIPTION OF THE METHOD

1.6.1.   Preliminary estimate of the partition coefficient

The partition coefficient is estimated preferably by using a calculation method (see Appendix 1), or where appropriate, from the ratio of the solubilities of the test substance ill the pure solvents (10).

1.6.2.   Shake-flask method

1.6.2.1.   Preparation

n-Octanol: the determination of the partition coefficient should be carried out with high purity analytical grade reagent.

Water: water distilled or double distilled in glass or quartz apparatus should be employed. For ionisable compounds, buffer solutions in place of water should be used if justified.

Note:

Water taken directly from an ion exchanger should not be used.

1.6.2.1.1.    Pre-saturation of the solvents

Before a partition coefficient is determined, the phases of the solvent system are mutually saturated by shaking at the temperature of the experiment. To do this, it is practical to shake two large stock bottles of high purity analytical grade n-octanol or water each with a sufficient quantity of the other solvent for 24 hours on a mechanical shaker and then to let them stand long enough to allow the phases to separate and to achieve a saturation state.

1.6.2.1.2.    Preparation for the test

The entire volume of the two-phase system should nearly fill the test vessel. This will help prevent loss of material due to volatilisation. The volume ratio and quantities of substance to be used are fixed by the following:

 the preliminary assessment of the partition coefficient (see above),

 the minimum quantity of test substance required for the analytical procedure, and

 the limitation of a maximum concentration in either phase of 0,01 mol per litre.

Three tests are carried out. In the first, the calculated volume ratio of n-octanol to water is used; in the second, this ratio is divided by two; and in the third, this ratio is multiplied by two (e.g. 1:1, 1:2, 2:1).

1.6.2.1.3.    Test substance

A stock solution is prepared in n-octanol pre-saturated with water. The concentration of this stock solution should be precisely determined before it is employed in the determination of the partition coefficient. This solution should be stored under conditions which ensure its stability.

1.6.2.2.   Test conditions

The test temperature should be kept constant (± 1 oC) and lie in the range of 20 to 25 oC.

1.6.2.3.   Measurement procedure

1.6.2.3.1.    Establishment of the partition equilibrium

Duplicate test vessels containing the required, accurately measured amounts of the two solvents together with the necessary quantity of the stock solution should be prepared for each of the test conditions.

The n-octanol phases should be measured by volume. The test vessels should either be placed in a suitable shaker or shaken by hand. When using a centrifuge tube, a recommended method is to rotate the tube quickly through 180o about its transverse axis so that any trapped air rises through the two phases. Experience has shown that 50 such rotations are usually sufficient for the establishment of the partition equilibrium. To be certain, 100 rotations in five minutes are recommended.

1.6.2.3.2.    Phase separation

When necessary, in order to separate the phases, centrifugation of the mixture should be carried out. This should be done in a laboratory centrifuge maintained at room temperature, or, if a non-temperature controlled centrifuge is used, the centrifuge tubes should be kept for equilibration at the test temperature for at least one hour before analysis.

1.6.2.4.   Analysis

For the determination of the partition coefficient, it is necessary to determine the concentrations of the test substance in both phases. This may be done by taking an aliquot of each of the two phases from each tube for each test condition and analyzing them by the chosen procedure. The total quantity of substance present in both phases should be calculated and compared with the quantity of the substance originally introduced.

The aqueous phase should be sampled by a procedure that minimises the risk of including traces of n-octanol: a glass syringe with a removable needle can be used to sample the water phase. The syringe should initially be partially filled with air. Air should be gently expelled while inserting the needle through the n-octanol layer. An adequate volume of aqueous phase is withdrawn into the syringe. The syringe is quickly removed from the solution and the needle detached. The contents of the syringe may then be used as the aqueous sample. The concentration in the two separated phases should preferably be determined by a substance-specific method. Examples of analytical methods which may be appropriate are:

 photometric methods,

 gas chromatography,

 high-performance liquid chromatography.

1.6.3.   HPLC method

1.6.3.1.   Preparation

A liquid chromatograph, fitted with a pulse-free pump and a suitable detection device, is required. The use of an injection valve with injection loops is recommended. The presence of polar groups in the stationary phase may seriously impair the performance of the HPLC column. Therefore, stationary phases should have the minimal percentage of polar groups (11). Commercial microparticulate reverse-phase packings or ready-packed columns can be used. A guard column may be positioned between the injection system and the analytical column.

HPLC grade methanol and HPLC grade water are used to prepare the eluting solvent, which is degassed before use. Isocratic elution should be employed. Methanol/water ratios with a minimum water content of 25 % should be used. Typically a 3:1 (v/v) methanol-water mixture is satisfactory for eluting compounds of log P 6 within an hour, at a flow rate of 1 ml/min. For compounds of high log P it may be necessary to shorten the elution time (and those of the reference compounds) by decreasing the polarity of the mobile phase or the column length.

Substances with very low solubility in n-octanol tend to give abnormally low log Pow values with the HPLC method; the peaks of such compounds sometimes accompany the solvent front. This is probably due to the fact that the partitioning process is too slow to reach the equilibrium in the time normally taken by an HPLC separation. Decreasing the flow rate and/or lowering the methanol/water ratio may then be effective to arrive at a reliable value.

Test and reference compounds should be soluble in the mobile phase in sufficient concentrations to allow their detection. Only in exceptional cases may additives be used with the methanol-water mixture, since additives will change the properties of the column. For chromatograms with additives it is mandatory to use a separate column of the same type. If methanol-water is not appropriate, other organic solvent-water mixtures call be used, e.g. ethanol-water or acetonitrile-water.

The pH of the eluent is critical for ionisable compounds. It should be within the operating pH range of the column, which is usually between 2 and 8. Buffering is recommended. Care must be taken to avoid salt precipitation and column deterioration which occur with some organic phase/buffer mixtures. HPLC measurements with silica-based stationary phases above pH 8 are not advisable since the use of an alkaline, mobile phase may cause rapid deterioration in the performance of the column.

The reference compounds should be the purest available. Compounds to be used for test or calibration purposes are dissolved in the mobile phase if possible.

The temperature during the measurements should not vary by more than ± 2 K.

1.6.3.2.    Measurement

The dead time to can be determined by using either a homologous series (e.g. n-alkyl methyl ketones) or unretained organic compounds (e.g. thiourea or formamide). For calculating the dead time to by using a homologous series, a set of at least seven members of a homologous series is injected and the respective retention times are determined. The raw retention times tr (nc + 1) are plotted as a function of tr(nc) and the intercept a and slope b of the regression equation:

tr(nc + 1) = a + b tr(nc)

are determined (nc = number of carbon atoms). The dead time to is then given by:

to = a/(1 - b)

The next step is to construct a correlation plot of log k values versus log p for appropriate reference compounds. In practice, a set of between 5 and 10 standard reference compounds whose log p is around the expected range are injected simultaneously and the retention times are determined, preferably on a recording integrator linked to the detection system. The corresponding logarithms of the capacity factors, log k, are calculated and plotted as a function of the log p determined by the shake-flask method. The calibration is performed at regular intervals, at least once daily, so that possible changes in column performance can be allowed for.

The test substance is injected in as small a quantity of mobile phase as possible. The retention time is determined (in duplicate), permitting the calculation of the capacity factor k. From the correlation graph of the reference compounds, the partition coefficient of the test substance can be interpolated. For very low and very high partition coefficients, extrapolation is necessary. In those cases particular care has to be taken of the confidence limits of the regression line.

2.   DATA

Shake-flask method

The reliability of the determined values of P can be tested by comparison of the means of the duplicate determinations with the overall mean.

3.   REPORTING

The test report shall, if possible, include the following information:

 precise specification of the substance (identity and impurities),

 when the methods are not applicable (e.g. surface active material), a calculated value or an estimate based on the individual n-octanol and water solubilities should be provided,

 all information and remarks relevant for the interpretation of results, especially with regard to impurities and physical state of the substance.

For shake-flask method:

 the result of the preliminary estimation, if any,

 temperature of the determination,

 data on the analytical procedures used in determining concentrations,

 time and speed of centrifugation, if used,

 the measured concentrations in both phases for each determination (this means that a total of 12 concentrations will be reported),

 the weight of the test substance, the volume of each phase employed in each test vessel and the total calculated amount of test substance present in each phase after equilibration,

 the calculated values of the partition coefficient (P) and the mean should be reported for each set of test conditions as should the mean for all determinations. If there is a suggestion of concentration dependency of the partition coefficient, this should be noted in the report,

 the standard deviation of individual P values about their mean should be reported,

 the mean P from all determinations should also be expressed as its logarithm (base 10),

 the calculated theoretical Pow when this value has been determined or when the measured value is > 104,

 pH of water used and of the aqueous phase during the experiment,

 if buffers are used, justification for the use of buffers in place of water, composition, concentration and pH of the buffers, pH of the aqueous phase before and after the experiment.

For HPLC method:

 the result of the preliminary estimation, if any,

 test and reference substances, and their purity,

 temperature range of the determinations,

 pH at which the determinations are made,

 details of the analytical and guard column, mobile phase and means of detection,

 retention data and literature log P values for reference compounds used in calibration,

 details of fitted regression line (log k versus log P),

 average retention data and interpolated log P value for the test compound,

 description of equipment and operating conditions,

 elution profiles,

 quantities of test and references substances introduced in the column,

 dead-time and how it was measured.

4.   REFERENCES

(1) OECD, Paris, 1981, Test Guideline 107, Decision of the Council C(81) 30 final.

(2) C. Hansch and A.J. Leo, Substituent Constants for Correlation Analysis in Chemistry and Biology, John Wiley, New York, 1979.

(3) Log P and Parameter Database, A tool for the quantitative prediction of bioactivity (C. Hansch, chairman, A.J. Leo, dir.) — Available from Pomona College Medical Chemistry Project 1982, Pomona College, Claremont, California 91711.

(4) L. Renberg, G. Sundström and K. Sundh-Nygärd, Chemosphere, 1980, vol. 80, p. 683.

(5) H. Ellgehausen, C. D'Hondt and R. Fuerer, Pestic. Sci., 1981, vol. 12, p. 219.

(6) B. McDuffie, Chemosphere, 1981, vol. 10, p. 73.

(7) W.E. Hammers et al., J. Chromatogr., 1982, vol. 247, p. 1.

(8) J.E. Haky and A.M. Young, J. Liq. Chromat., 1984, vol. 7, p. 675.

(9) S. Fujisawa and E. Masuhara, J. Biomed. Mat. Res., 1981, vol. 15, p. 787.

(10) O. Jubermann, Verteilen und Extrahieren, in Methoden der Organischen Chemie (Houben Weyl), Allgemeine Laboratoriumpraxis (edited by E. Muller), Georg Thieme Verlag, Stuttgart, 1958, Band I/1, p. 223-339.

(11) R.F. Rekker and H.M. de Kort, Euro. J. Med. Chem., 1979, vol. 14, p. 479.

(12) A. Leo, C. Hansch and D. Elkins, Partition coefficients and their uses. Chem. Rev., 1971, vol. 71, p. 525.

(13) R.F. Rekker, The Hydrophobic Fragmental Constant, Elsevier, Amsterdam, 1977.

(14) NF T 20-043 AFNOR (1985). Chemical products for industrial use — Determination of partition coefficient — Flask shaking method.

(15) C.V. Eadsforth and P. Moser, Chemosphere, 1983, vol. 12, p. 1459.

(16) A. Leo, C. Hansch and D. Elkins, Chem. Rev., 1971, vol. 71, p. 525.

(17) C. Hansch, A. Leo, S.H. Unger, K.H. Kim, D. Nikaitani and E.J. Lien, J. Med. Chem., 1973, vol. 16, p. 1207.

(18) W.B. Neely, D.R. Branson and G.E. Blau, Environ. Sci. Technol., 1974, vol. 8, p. 1113.

(19) D.S. Brown and E.W. Flagg, J. Environ. Qual., 1981, vol. 10, p. 382.

(20) J.K. Seydel and K.J. Schaper, Chemische Struktur und biologische Aktivität von Wirkstoffen, Verlag Chemie, Weinheim, New York, 1979.

(21) R. Franke, Theoretical Drug Design Methods, Elsevier, Amsterdam, 1984.

(22) Y.C. Martin, Quantitative Drug Design, Marcel Dekker, New York, Base1, 1978.

(23) N.S. Nirrlees, S.J. Noulton, C.T. Murphy, P.J. Taylor; J. Med. Chem., 1976, vol. 19, p. 615.

Appendix 1

Calculation/estimation methods

INTRODUCTION

A general introduction to calculation methods, data and examples are provided in the Handbook of Chemical Property Estimation Methods (a).

Calculated values of Pow can be used:

 for deciding which of the experimental methods is appropriate (shake-flask range: log Pow: - 2 to 4, HPLC range: log Pow: 0 to 6),

 for selecting the appropriate test conditions (e.g. reference substances for HPLC procedures, volume ratio n-octanol/water for shake flask method),

 as a laboratory internal check on possible experimental errors,

 for providing a Pow-estimate in cases where the experimental methods cannot be applied for technical reasons.

ESTIMATION METHOD

Preliminary estimate of the partition coefficient

The value of the partition coefficient can be estimated by the use of the solubilities of the test substance in the pure solvents: For this:

image

CALCULATION METHODS

Principle of the calculation methods

All calculation methods are based on the formal fragmentation of the molecule into suitable substructures for which reliable log Pow-increments are known. The log Pow of the whole molecule is then calculated as the sum of its corresponding fragment values plus the sum of correction terms for intramolecular interactions.

Lists of fragment constants and correction terms ate available (b)(c)(d)(e);. Some are regularly updated (b).

Quality criteria

In general, the reliability of the calculation method decreases with increasing complexity of the compound under study. In the case of simple molecules with low molecular weight and one or two functional groups, a deviation of 0,1 to 0,3 log Pow units between the results of the different fragmentation methods and the measured value can be expected. In the case of more complex molecules the margin of error can be greater. This will depend on the reliability and availability of fragment constants, as well as on the ability to recognise intramolecular interactions (e.g. hydrogen bonds) and the correct use of the correction terms (less of a problem with the computer software CLOGP-3) (b). In the case of ionising compounds the correct consideration of the charge or degree of ionisation is important.

Calculation procedures

The original hydrophobic substituent constant, π, introduced by Fujira et al. (f) is defined as:

πx = log Pow (PhX) - log Pow (PhH)

where Pow (PhX) is the partition coefficient of an aromatic derivative and Pow (PhH) that of the parent compound

(e.g. πCl = log Pow (C6H5Cl) - log Pow (C6H6) = 2,84 - 2,13 = 0,71).

According to its definition the π-method is applicable predominantly for aromatic substitution. π-values for a large number of substituents have been tabulated (b)(c)(d). They are used for the calculation of log Pow for aromatic molecules or substructures.

According to Rekker (g) the log Pow value is calculated as follows:

image

where fi represents the different molecular fragment constants and ai the frequency of their occurrence in the molecule under investigation. The correction terms can be expressed as an integral multiple of one single constant Cm (so-called magic constant). The fragment constants fi and Cm were determined from a list of 1 054 experimental Pow values (825 compounds) using multiple regression analysis (c)(h). The determination of the interaction terms is carried out according to set rules described in the literature (e)(h)(i).

According to Hansch and Leo (c), the log Pow value is calculated from:

image

where fi represents the different molecular fragment constants, Fj the correction terms and ai, bj the corresponding frequencies of occurrence. Derived from experimental Pow values, a list of atomic and group fragmental values and a list of correction terms Fj (so-called factors) were determined by trial and error. The correction terms have been ordered into several different classes (a)(c). It is relatively complicated and time consuming to take into account all the rules and correction terms. Software packages have been developed (b).

The calculation of log Pow of complex molecules can be considerably improved, if the molecule is dissected into larger substructures for which reliable log Pow values are available, either from tables (b)(c) or from one's own measurements. Such fragments (e.g. heterocycles, anthraquinone, azobenzene) can then be combined with the Hansch π-values or with Rekker or Leo fragment constants.

Remarks

(i) The calculation methods can only be applied to partly or fully ionised compounds when it is possible to take the necessary correction factors into account;

(ii) if intramolecular hydrogen bonds can be assumed, the corresponding correction terms (approx. + 0,6 to + 1,0 log Pow units) have to be added (a). Indications for the presence of such bonds can be obtained from stereo models or spectroscopic data of the molecule;

(iii) If several tautomeric forms are possible, the most likely form should be used as the basis of the calculation;

(iv) the revisions of lists of fragment constants should be followed carefully.

Report

When using calculation/estimation methods, the test report shall, if possible, include the following information:

 description of the substance (mixture, impurities, etc.),

 indication of any possible intramolecular hydrogen bonding, dissociation, charge and any other unusual effects (e.g. tautomerism),

 description of the calculation method,

 identification or supply of database,

 peculiarities in the choice of fragments,

 comprehensive documentation of the calculation.

LITERATURE

(a) W.J. Lyman, W.F. Reehl and D.H. Rosenblatt (ed.), Handbook of Chemical Property Estimation Methods, McGraw-Hill, New York, 1983.

(b) Pomona College, Medicinal Chemistry Project, Claremont, California 91711, USA, Log P Database and Med. Chem. Software (Program CLOGP-3).

(c) C. Hansch, A.J. Leo, Substituent Constants for Correlation Analysis in Chemistry and Biology, John Wiley, New York, 1979.

(d) A. Leo, C. Hansch, D. Elkins, Chem. Rev., 1971, vol. 71, p. 525.

(e) R.F. Rekker, H.M. de Kort, Eur. J. Med. Chem. -Chill. Ther. 1979, vol. 14, p. 479.

(f) T. Fujita, J. Iwasa and C. Hansch, J. Amer. Chem. Soc., 1964, vol. 86, p. 5175.

(g) R.F. Rekker, The Hydrophobic Fragmental Constant, Pharmacochemistry Library, Elsevier, New York, 1977, vol. 1.

(h) C.V. Eadsforth, P. Moser, Chemosphere, 1983, vol. 12, p. 1459.

(i) R.A. Scherrer, ACS, American Chemical Society, Washington D.C., 1984, Symposium Series 255, p. 225.

Appendix 2

Recommended Reference Substances for the HLPC Method



No

Reference Substance

log Pow

pKa

1

2-Butanone

0,3

 

2

4-Acetylpyridine

0,5

 

3

Aniline

0,9

 

4

Acetanilide

1,0

 

5

Benzylalcohol

1,1

 

6

p-Methoxyphenol

1,3

pKa = 10,26

7

Phenoxy acetic acid

1,4

pKa = 3,12

8

Phenol

1,5

pKa = 9,92

9

2,4-Dinitrophenol

1,5

pKa = 3,96

10

Benzonitrile

1,6

 

11

Phenylacetonitrile

1,6

 

12

4-Methylbenzyl alcohol

1,6

 

13

Acetophenone

1,7

 

14

2-Nitrophenol

1,8

pKa = 7,17

15

3-Nitrobenzoic acid

1,8

pKa = 3,47

16

4-Chloraniline

1,8

pKa = 4,15

17

Nitrobenzene

1,9

 

18

Cinnamic alcohol

1,9

 

19

Benzoic acid

1,9

pKa = 4,19

20

p-Cresol

1,9

pKa = 10,17

21

Cinnamic acid

2,1

pKa = 3,89 cis 4,44 trans

22

Anisole

2,1

 

23

Methylbenzoate

2,1

 

24

Benzene

2,1

 

25

3-Methylbenzoic acid

2,4

pKa = 4,27

26

4-Chlorophenol

2,4

pKa = 9,1

27

Trichloroethylene

2,4

 

28

Atrazine

2,6

 

29

Ethylbenzoate

2,6

 

30

2,6-Dichlorobenzonitrile

2,6

 

31

3-Chlorobenzoic acid

2,7

pKa = 3,82

32

Toluene

2,7

 

33

1-Naphthol

2,7

pKa = 9,34

34

2,3-Dichloroaniline

2,8

 

35

Chlorobenzene

2,8

 

36

Allyl-phenylether

2,9

 

37

Bromobenzene

3,0

 

38

Ethylbenzene

3,2

 

39

Benzophenone

3,2

 

40

4-Phenylphenol

3,2

pKa = 9,54

41

Thymol

3,3

 

42

1,4-Dichlorobenzene

3,4

 

43

Diphenylamine

3,4

pKa = 0,79

44

Naphthalene

3,6

 

45

Phenylbenzoate

3,6

 

46

Isopropylbenzene

3,7

 

47

2,4,6-Trichlorophenol

3,7

pKa = 6

48

Biphenyl

4,0

 

49

Benzylbenzoate

4,0

 

50

2,4-Dinitro-6 sec. butyophenol

4,1

 

51

1,2,4-Trichlorobenzene

4,2

 

52

Dodecanoic acid

4,2

 

53

Diphenylether

4,2

 

54

n-Butylbenzene

4,5

 

55

Phenanthrene

4,5

 

56

Fluoranthene

4,7

 

57

Dibenzyl

4,8

 

58

2,6-Diphenylpyridine

4,9

 

59

Triphenylamine

5,7

 

60

DDT

6,2

 

Other reference substances of low log Pow

1

Nicotinic acid

- 0,07

 

A.9.   FLASH-POINT

1.   METHOD

1.1.   INTRODUCTION

It is useful to have preliminary information on the flammability of the substance before performing this test. The test procedure is applicable to liquid substances whose vapours can be ignited by ignition sources. The test methods listed in this text are only reliable for flash-point ranges which are specified in the individual methods.

The possibility of chemical reactions between the substance and the sample holder should be considered when selecting the method to be used.

1.2.   DEFINITIONS AND UNITS

The flash-point is the lowest temperature, corrected to a pressure of 101,325 kPa, at which a liquid evolves vapours, under the conditions defined in the test method, in such an amount that a flammable vapour/air mixture is produced in the test vessel.

Units: oC

t = T - 273,15

(t in oC and T in K)

1.3.   REFERENCE SUBSTANCES

Reference substances do not need to be employed in all cases when investigating a new substance. They should primarily serve to check the performance of the method from time to time and to allow comparison with results from other methods.

1.4.   PRINCIPLE OF THE METHOD

The substance is placed in a test vessel and heated or cooled to the test temperature according to the procedure described in the individual test method. Ignition trials are carried out in order to ascertain whether or not the sample flashed at the test temperature.

1.5.   QUALITY CRITERIA

1.5.1.   Repeatability

The repeatability varies according to flash-point range and the test method used; maximum 2 oC.

1.5.2.   Sensitivity

The sensitivity depends on the test method used.

1.5.3.   Specificity

The specificity of some test methods is limited to certain flash-point ranges and subject to substance-related data (e.g. high viscosity).

1.6.   DESCRIPTION OF THE METHOD

1.6.1.   Preparations

A sample of the test substance is placed in a test apparatus according to 1.6.3.1 and/or 1.6.3.2.

For safety, it is recommended that a method utilising a small sample size, circa 2 cm3, be used for energetic or toxic substances.

1.6.2.   Test conditions

The apparatus should, as far as is consistent with safety, be placed in a draught-free position.

1.6.3.   Performance of the test

1.6.3.1.   Equilibrium method

See ISO 1516, ISO 3680, ISO 1523, ISO 3679.

1.6.3.2.   Non-equilibrium method

See BS 2000 part 170, NF M07-011, NF T66-009.

See EN 57, DIN 51755 part 1 (for temperatures from 5 to 65 oC), DIN 51755 part 2 (for temperatures below 5 oC), NF M07-036.

See ASTM D 56.

See ISO 2719, EN 11, DIN 51758, ASTM D 93, BS 2000-34, NF M07-019.

When the flash-point, determined by a non-equilibrium method in 1.6.3.2, is found to be 0 ± 2 oC, 21 ± 2 oC or 55 ± 2 oC, it should be confirmed by an equilibrium method using the same apparatus.

Only the methods which can give the temperature of the flash-point may be used for a notification.

To determine the flash-point of viscous liquids (paints, gums and similar) containing solvents, only apparatus and test methods suitable for determining the flash-point of viscous liquids may be used.

See ISO 3679, ISO 3680, ISO 1523, DIN 53213 part 1.

2.  DATA

3.   REPORTING

The test report shall, if possible, include the following information:

 the precise specification of the substance (identification and impurities),

 the method used should be stated as well as any possible deviations,

 the results and any additional remarks relevant for the interpretation of results.

4.   REFERENCES

None.

A.10.   FLAMMABILITY (SOLIDS)

1.   METHOD

1.1.   INTRODUCTION

It is useful to have preliminary information on potentially explosive properties of the substance before performing this test.

This test should only be applied to powdery, granular or paste-like substances.

In order not to include all substances which can be ignited but only those which burn rapidly or those whose burning behaviour is in any way especially dangerous, only substances whose burning velocity exceeds a certain limiting value are considered to be highly flammable.

It can be especially dangerous if incandescence propagates through a metal powder because of the difficulties in extinguishing a fire. Metal powders should be considered highly flammable if they support spread of incandescence throughout the mass within a specified time.

1.2.   DEFINITION AND UNITS

Burning time expressed in seconds.

1.3.   REFERENCE SUBSTANCES

Not specified.

1.4.   PRINCIPLE OF THE METHOD

The substance is formed into an unbroken strip or powder train about 250 mm long and a preliminary screening test performed to determine if, on ignition by a gas flame, propagation by burning with flame or smouldering occurs. If propagation over 200 mm of the train occurs within a specified time then a full test programme to determine the burning rate is carried out.

1.5.   QUALITY CRITERIA

Not stated.

1.6.   DESCRIPTION OF METHOD

1.6.1.   Preliminary screening test

The substance is formed into an unbroken strip or powder train about 250 mm long by 20 mm wide by 10 mm high on a non-combustible, non-porous and low heat-conducting base plate. A hot flame from a gas burner (minimum diameter 5 mm) is applied to one end of the powder train until the powder ignites or for a maximum of two minutes (five minutes for powders of metals or metal-alloys). It should be noted whether combustion propagates along 200 mm of the train within the 4 minutes test period (or 40 minutes for metal powders). If the substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the four minutes (or 40 minutes) test period, then the substance should not be considered as highly flammable and no further testing is required. If the substance propagates burning of a 200 mm length of the powder train in less than four minutes, or less than 40 minutes for metal powders, the procedure described below (point 1.6.2. and following) should be carried out.

1.6.2.   Burning rate test

1.6.2.1.   Preparation

Powdery or granular substances are loosely filled into a mould 250 mm long with a triangular cross-section of inner height 10 mm and width 20 mm. On both sides of the mould in a longitudinal direction two metal plates are mounted as lateral limitations which project 2 mm beyond the upper edge of the triangular cross section (figure). The mould is then dropped three times from a height of 2 cm onto a solid surface. If necessary the mould is then filled up again. The lateral limitations are then removed and the excess substance scraped off. A non-combustible, non-porous and low heat-conducting base plate is placed on top of the mould, the apparatus inverted and the mould removed.

Paste-like substances are spread on a non-combustible, non-porous and low heat-conducting base plate in the form of a rope 250 mm in length with a cross section of about 1 cm2.

1.6.2.2.   Test conditions

In the case a moisture-sensitive substance, the test should be carried out as quickly as possible after its removal from the container.

1.6.2.3.   Performance of the test

Arrange the pile across the draught in a fume cupboard.

The air-speed should be sufficient to prevent fumes escaping into the laboratory and should not be varied during the test. A draught screen should be erected around the apparatus.

A hot flame from a gas burner (minimum diameter of 5 mm) is used to ignite the pile at one end. When the pile has burned a distance of 80 mm, the rate of burning over the next 100 mm is measured.

The test is performed six times, using a clean cool plate each time, unless a positive result is observed earlier.

2.   DATA

The burning time from the preliminary screening test (1.6.1) and the shortest burning time in up to six tests (1.6.2.3) are relevant for evaluation.

3.   REPORTING

3.1.   TEST REPORT

The test report shall, if possible, include the following information:

 the precise specification of the substance (identification and impurities),

 a description of the substance to be tested, its physical state including moisture content,

 results from the preliminary screening test and from the burning rate test if performed,

 all additional remarks relevant to the interpretation of results.

3.2.   INTERPRETATION OF THE RESULT

Powdery, granular or paste-1ike substances are to be considered as highly flammable when the time of burning in any tests carried out according to the test procedure described in 1.6.2 is less than 45 seconds. Powders of metals or metal-alloys are considered to be highly flammable when they can be ignited and the flame or the zone of reaction spreads over the whole sample in 10 minutes or less.

4.   REFERENCES

NF T 20-042 (September 85) Chemical products for industrial use. Determination of the flammability of solids.

Appendix

Figure

Mould and accessories for the preparation of the pile

(All dimensions in millimetres)

Length of the mould: 250 mmMaterial: aluminium

A.11.   FLAMMABILITY (GASES)

1.   METHOD

1.1.   INTRODUCTION

This method allows a determination of whether gases mixed with air at room temperature (circa 20 oC) and atmospheric pressure are flammable and, if so, over what range of concentrations. Mixtures of increasing concentrations of the test gas with air are exposed to an electrical spark and it is observed whether ignition occurs.

1.2.   DEFINITION AND UNITS

The range of flammability is the range of concentration between the lower and the upper explosion limits. The lower and the upper explosion limits are those limits of concentration of the flammable gas in admixture with air at which propagation of a flame does not occur.

1.3.   REFERENCE SUBSTANCES

Not specified.

1.4.   PRINCIPLE OF THE METHOD

The concentration of gas in air is increased step by step and the mixture is exposed at each stage to an electrical spark.

1.5.   QUALITY CRITERIA

Not stated.

1.6.   DESCRIPTION OF THE METHOD

1.6.1.   Apparatus

The test vessel is an upright glass cylinder having a minimum inner diameter of 50 mm and a minimum height of 300 mm. The ignition electrodes are separated by a distance of 3 to 5 mm and are placed 60 mm above the bottom of the cylinder. The cylinder is fitted with a pressure-release opening. The apparatus has to be shielded to restrict any explosion damage.

A standing induction spark of 0,5 sec. duration, which is generated from a high voltage transformer with an output voltage of 10 to 15 kV (maximum of power input 300 W), is used as the ignition source. An example of a suitable apparatus is described in reference (2).

1.6.2.   Test conditions

The test must be performed at room temperature (circa 20 oC).

1.6.3.   Performance of the test

Using proportioning pumps, a known concentration of gas in air is introduced into the glass cylinder. A spark is passed through the mixture and it is observed whether or not a flame detaches itself from the ignition source and propagates independently. The gas concentration is varied in steps of 1 % vol. until ignition occurs as described above.

If the chemical structure of the gas indicates that it would be non-flammable and the composition of the stoichiometric mixture with air can be calculated, then only mixtures in the range from 10 % less than the stoichiometric composition to 10 % greater than this composition need be tested in 1 % steps.

2.   DATA

The occurrence of flame propagation is the only relevant information data for the determination of this property.

3.   REPORTING

The test report shall, if possible, include the following information:

 the precise specification of the substance (identification and impurities),

 a description, with dimensions, of the apparatus used,

 the temperature at which the test was performed,

 the tested concentrations and the results obtained,

 the result of the test: non-flammable gas or highly flammable gas,

 if it is concluded that the gas is non-flammable then the concentration range over which it was tested in 1 % steps should be stated,

 all information and remarks relevant to the interpretation of results have to be reported.

4.   REFERENCES

(1) NF T 20-041 (September 85) Chemical products for industrial use. Determination of the flammability of gases.

(2) W. Berthold, D. Conrad, T. Grewer, H. Grosse-Wortmann ‘Entwicklung einer Standard-Apparatur zur Messung von Explosionsgrenzen’. Chem.-Ing.- Tech. 1984, vo1. 56, 2, 126-127., T. Redeker und H. Schacke, p. 126-127.

A.12.   FLAMMABILITY (CONTACT WITH WATER)

1.   METHOD

1.1.   INTRODUCTION

This test method can be used to determine whether the reaction of a substance with water or damp air leads to the development of dangerous amounts of gas or gases which may be highly flammable.

The test method can be applied to both solid and liquid substances. This method is not applicable to substances which spontaneously ignite when in contact with air.

1.2.   DEFINITIONS AND UNITS

Highly flammable: substances which, in contact with water or damp air, evolve highly flammable gases in dangerous quantities at a minimum rate of 1 litre/kg per hour.

1.3.   PRINCIPLE OF THE METHOD

The substance is tested according to the step by step sequence described below; if ignition occurs at any step, no further testing is necessary. If it is known that the substance does not react violently with water then proceed to step 4 (1.3.4).

1.3.1.   Step 1

The test substance is placed in a trough containing distilled water at 20 oC and it is noted whether or not the evolved gas ignites.

1.3.2.   Step 2

The test substance is placed on a filter paper floating on the surface of a dish containing distilled water at 20 oC and it is noted whether or not the evolved gas ignites. The filter paper is merely to keep the substance in one place to increase the chances of ignition.

1.3.3.   Step 3

The test substance is made into a pile approximately 2 cm high and 3 cm diameter. A few drops of water are added to the pile and it is noted whether or not the evolved gas ignites.

1.3.4.   Step 4

The test substance is mixed with distilled water at 20 oC and the rate of evolution of gas is measured over a period of seven hours, at one-hour intervals. If the rate of evolution is erratic, or is increasing, after seven hours, the measuring time should be extended to a maximum time of five days. The test may be stopped if the rate at any time exceeds 1 litre/kg per hour.

1.4.   REFERENCE SUBSTANCES

Not specified.

1.5.   QUALITY CR1TERIA

Not stated.

1.6.   DESCRIPTION OF METHODS

1.6.1.   Step 1

1.6.1.1.   Test conditions

The test is performed at room temperature (circa 20 oC).

1.6.1.2.   Performance of the test

A small quantity (approximately 2 mm diameter) of the test substance should be placed in a trough containing distilled water. A note should be made of whether (i) any gas is evolved and (ii) if ignition of the gas occurs. If ignition of the gas occurs then no further testing of the substance is needed because the substance is regarded as hazardous.

1.6.2.   Step 2

1.6.2.1.   Apparatus

A filter-paper is floated flat on the surface of distilled water in any suitable vessel, e.g. a 100 mm diameter evaporating dish.

1.6.2.2.   Test conditions

The test is performed at room temperature (circa 20 oC).

1.6.2.3.   Performance of the test

A small quantity of the test substance (approximately 2 mm diameter) is placed onto the centre of the filter-paper. A note should be made of whether (i) any gas is evolved and (ii) if ignition of the gas occurs. If ignition of the gas occurs then no further testing of the substance is needed because the substance is regarded as hazardous.

1.6.3.   Step 3

1.6.3.1.   Test conditions

The test is performed at room temperature (circa 20 oC).

1.6.3.2.   Performance of the test

The test substance is made into a pile approximately 2 cm high and 3 cm diameter with an indentation in the top. A few drops of water are added to the hollow and a note is made of whether (i) any gas is evolved and (ii) if ignition of the gas occurs. If ignition of the gas occurs then no further testing of the substance is needed because the substance is regarded as hazardous.

1.6.4.   Step 4

1.6.4.1.   Apparatus

The apparatus is set up as shown in the figure.

1.6.4.2.   Test conditions

Inspect the container of the test substance for any powder < 500 μm (particle size). If the powder constitutes more than 1 % w/w of the total, or if the sample is friable, then the whole of the substance should be ground to a powder before testing to allow for a reduction in particle size during storage and handling; otherwise the substance is to be tested as received. The test should be performed at room temperature (circa 20 oC) and atmospheric pressure.

1.6.4.3.   Performance of the test

10 to 20 ml of water are put into the dropping funnel of the apparatus and 10 g of substance are put in the conical flask. The volume of gas evolved can be measured by any suitable means. The tap of the dropping funnel is opened to let the water into the conical flask and a stop watch is started. The gas evolution is measured each hour during a seven hour period. If, during this period, the gas evolution is erratic, or if, at the end of this period, the rate of gas evolution is increasing, then measurements should be continued for up to five days. If, at any time of measurement, the rate of gas evolution exceeds 1 litre/kg per hour, the test can be discontinued. This test should be performed in triplicate.

If the chemical identity of the gas is unknown, the gas should be analysed. When the gas contains highly flammable components and it is unknown whether the whole mixture is highly flammable, a mixture of the same composition has to be prepared and tested according to the method A.11.

2.   DATA

The substance is considered hazardous if:

 spontaneous ignition takes place in any step of the test procedure,

 or

 there is evolution of flammable gas at a rate greater than 1 litre/kg of the substance per hour.

3.   REPORTING

The test report shall, if possible, include the following information:

 the precise specification of the substance (identification and impurities),

 details of any initial preparation of the test substance,

 the results of the tests (steps 1, 2, 3 and 4),

 the chemical identity of gas evolved,

 the rate of evolution of gas if step 4 (1.6.4) is performed,

 any additional remarks relevant to the interpretation of the results.

4.   REFERENCES

(1) Recommendations on the transport of dangerous goods, test and criteria, 1990, United Nations, New York.

(2) NF T 20-040 (September 85) Chemical products for industrial use. Determination of the flammability of gases formed by the hydrolysis of solid and liquid products.

Appendix

Figure

Apparatus

image

A.13.   PYROPHORIC PROPERTIES OF SOLIDS AND LIQUIDS

1.   METHOD

1.1.   INTRODUCTION

The test procedure is applicable to solid or liquid substances, which, in small amounts, will ignite spontaneously a short time after coming into contact with air at room temperature (circa 20 oC).

Substances which need to be exposed to air for hours or days at room temperature or at elevated temperatures before ignition occurs are not covered by this test method.

1.2.   DEFINITIONS AND UNITS

Substances are considered to have pyrophoric properties if they ignite or cause charring under the conditions described in 1.6.

The auto-flammability of liquids may also need to be tested using method A.15. Auto-ignition temperature (liquids and gases).

1.3.   REFERENCE SUBSTANCES

Not specified.

1.4.   PRINCIPLE OF THE METHOD

The substance, whether solid or liquid, is added to an inert carrier and brought into contact with air at ambient temperature for a period of five minutes. If liquid substances do not ignite then they are absorbed onto filter paper and exposed to air at ambient temperature (circa 20 oC) for five minutes. If a solid or liquid ignites, or a liquid ignites or chars a filter paper, then the substance is considered to be pyrophoric.

1.5.   QUALITY CRITERIA

Repeatability: because of the importance in relation to safety, a single positive result is sufficient for the substance to be considered pyrophoric.

1.6.   DESCRIPTION OF THE TEST METHOD

1.6.1.   Apparatus

A porcelain cup of circa 10 cm diameter is filled with diatomaceous earth to a height of about 5 mm at room temperature (circa 20 oC).

Note:

Diatomaceous earth or any other comparable inert substance which is generally obtainable shall be taken as representative of soil onto which the test substance might be spilled in the event of an accident.

Dry filter paper is required for testing liquids which do not ignite on contact with air when in contact with an inert carrier.

1.6.2.   Performance of the test

(a)   Powdery solids

1 to 2 cm3 of the substance to be tested is poured from circa 1 m height onto a non-combustible surface and it is observed whether the substance ignites during dropping or within five minutes of settling.

The test is performed six times unless ignition occurs;

(b)   liquids

Circa 5 cm3 of the liquid to be tested is poured into the prepared porcelain cup and it is observed whether the substance ignites within five minutes.

If no ignition occurs in the six tests, perform the following tests:

A 0,5 ml test sample is delivered from a syringe to an indented filter paper and it is observed whether ignition or charring of the filter paper occurs within five minutes of the liquid being added. The test is performed three times unless ignition or charring occurs.

2.   DATA

2.1.   TREATMENT OF RESULTS

Testing can be discontinued as soon as a positive result occurs in any of the tests.

2.2.   EVALUATION

If the substance ignites within five minutes when added to an inert carrier and exposed to air, or a liquid substance chars or ignites a filter paper within five minutes when added and exposed to air, it is considered to be pyrophoric.

3.   REPORTING

The test report shall, if possible, include the following information:

 the precise specification of the substance (identification and impurities),

 the results of the tests,

 any additional remark relevant to the interpretation of the results.

4.   REFERENCES

(1) NF T 20-039 (September 85) Chemical products for industrial use. Determination of the spontaneous flammability of solids and liquids.

(2) Recommendations on the Transport of Dangerous Goods, Test and criteria, 1990, United Nations, New York.

A.14.   EXPLOSIVE PROPERTIES

1.   METHOD

1.1.   INTRODUCTION

The method provides a scheme of testing to determine whether a solid or a pasty substance presents a danger of explosion when submitted to the effect of a flame (thermal sensitivity), or to shock or friction (sensitivity to mechanical stimuli), and whether a liquid substance presents a danger of explosion when submitted to the effect of a flame or shock.

The method comprises three parts:

(a) a test of thermal sensitivity (1);

(b) a test of mechanical sensitivity with respect to shock (1);

(c) a test of mechanical sensitivity with respect to friction (1).

The method yields data to assess the likelihood of initiating an explosion by means of certain common stimuli. The method is not intended to ascertain whether a substance is capable of exploding under any conditions.

The method is appropriate for determining whether a substance will present a danger of explosion (thermal and mechanical sensitivity) under the particular conditions specified in the directive. It is based on a number of types of apparatus which are widely used internationally (1) and which usually give meaningful results. It is recognised that the method is not definitive. Alternative apparatus to that specified may be used provided that it is internationally recognised and the results can be adequately correlated with those from the specified apparatus.

The tests need not be performed when available thermodynamic information (e.g. heat of formation, heat of decomposition) and/or absence of certain reactive groups (2) in the structural formula establishes beyond reasonable doubt that the substance is incapable of rapid decomposition with evolution of gases or release of heat (i.e. the material does not present any risk of explosion). A test of mechanical sensitivity with respect to friction is not required for liquids.

1.2.   DEFINITIONS AND UNITS

Explosive:

Substances which may explode under the effect of flame or which are sensitive to shock or friction in the specified apparatus (or are more mechanically sensitive than 1,3-dinitrobenzene in alternative apparatus).

1.3.   REFERENCE SUBSTANCES

1,3-dinitrobenzene, technical crystalline product sieved to pass 0,5 mm, for the friction and shock methods.

Perhydro-1,3,5-trinitro-1,3,5-triazine (RDX, hexogen, cyclonite — CAS 121-82-4), recrystallised from aqueous cyclohexanone, wet-sieved through a 250 μm and retained on a 150 μm sieve and dried at 103 ± 2 oC (for four hours) for the second series of friction and shock tests.

1.4.   PRINCIPLE OF THE METHOD

Preliminary tests are necessary to establish safe conditions for the performance of the three tests of sensitivity.

1.4.1.   Safety-in-handling tests (3)

For safety reasons, before performing the main tests, very small samples (circa 10 mg) of the substance are subjected to heating without confinement in a gas flame, to shock in any convenient form of apparatus and to friction by the use of a mallet against an anvil or any form of friction machine. The objective is to ascertain if the substance is so sensitive and explosive that the prescribed sensitivity tests, particularly that of thermal sensitivity, should be performed with special precautions so as to avoid injury to the operator.

1.4.2.   Thermal sensitivity

The method involves heating the substance in a steel tube, closed by orifice plates with differing diameters of hole, to determine whether the substance is liable to explode under conditions of intense heat and defined confinement.

1.4.3.   Mechanical sensitivity (shock)

The method involves subjecting the substance to the shock from a specified mass dropped from a specified height.

1.4.4.   Mechanical sensitivity (friction)

The method involves subjecting solid or pasty substances to friction between standard surfaces under specified conditions of load and relative motion.

1.5.   QUALITY CRITERIA

Not stated.

1.6.   DESCRIPTION OF METHOD

1.6.1.   Thermal sensitivity (effect of a flame)

1.6.1.1.   Apparatus

The apparatus consists of a non-reusable steel tube with its re-usable closing device (figure 1), installed in a heating and protective device. Each tube is deep-drawn from sheet steel (see Appendix) and has an internal diameter of 24 mm, a length of 75 mm and wall thickness of 0,5 mm. The tubes are flanged at the open end to enable them to be closed by the orifice plate assembly. This consists of a pressure-resistant orifice plate, with a central hole, secured firmly to a tube using a two-part screw joint (nut and threaded collar). The nut and threaded collar are made from chromium-manganese steel (see Appendix) which is spark-free up to 800 oC. The orifice plates are 6 mm thick, made from heat-resistant steel (see Appendix), and are available with a range of diameters of opening.

1.6.1.2.   Test conditions

Normally the substance is tested as received although in certain cases, e.g. if pressed, cast or otherwise condensed, it may be necessary to test the substance after crushing.

For solids, the mass of material to be used in each test is determined using a two-stage dry run procedure. A tared tube is filled with 9 cm3 of substance and the substance tamped with 80 N force applied to the total cross-section of the tube. For reasons of safety or in cases where the physical form of the sample can be changed by compression other filling procedures may be used; e.g. if the substance is very friction sensitive then tamping is not appropriate. If the material is compressible then more is added and tamped until the tube is filled to 55 mm from the top. The total mass used to fill the tube to the 55 mm level is determined and two further increments, each tamped with 80 N force, are added. Material is then either added with tamping, or taken out, as required, to leave the tube filled to a level 15 mm from the top. A second dry run is performed, starting with a tamped quantity of a third of the total mass found in the first dry run. Two more of these increments are added with 80 N tamping and the level of the substance in the tube adjusted to 15 mm from the top by addition or subtraction of material as required. The amount of solid determined in the second dry run is used for each trial; filling being performed in three equal amounts, each compressed to 9 cm3 by whatever force is necessary. (This may be facilitated by the use of spacing rings).

Liquids and gels are loaded into the tube to a height of 60 mm taking particular care with gels to prevent the formation of voids. The threaded collar is slipped onto the tube from below, the appropriate orifice plate is inserted and the nut tightened after applying some molybdenum disulphide based lubricant. It is essential to check that none of the substance is trapped between the flange and the plate, or in the threads.

Heating is provided by propane taken from an industrial cylinder, fitted with a pressure regulator (60 to 70 mbar), through a meter and evenly distributed (as indicated by visual observation of the flames from the burners) by a manifold to four burners. The burners are located around the test chamber as shown in figure 1. The four burners have a combined consumption of about 3,2 litres of propane per minute. Alternative fuel gases and burners may be used but the heating rate must be as specified in figure 3. For all apparatus, the heating rate must be checked periodically using tubes filled with dibutyl phthalate as indicated in figure 3.

1.6.1.3.   Performance of the tests

Each test is performed until either the tube is fragmented or the tube has been heated for five minutes. A test resulting in the fragmentation of the tube into three or more pieces, which in some cases may be connected to each other by narrow strips of metal as illustrated in figure 2, is evaluated as giving an explosion. A test resulting in fewer fragments or no fragmentation is regarded as not giving an explosion.

A series of three tests with a 6,0 mm diameter orifice plate is first performed and, if no explosions are obtained, a second series of three tests is performed with a 2,0 mm diameter orifice plate. If an explosion occurs during either test series then no further tests are required.

1.6.1.4.   Evaluation

The test result is considered positive if an explosion occurs in either of the above series of tests.

1.6.2.   Mechanical sensitivity (shock)

1.6.2.1.   Apparatus (figure 4)

The essential parts of a typical fall hammer apparatus are a cast steel block with base, anvil, column, guides, drop weights, release device and a sample holder. The steel anvil 100 mm (diameter) × 70 mm (height) is screwed to the top of a steel block 230 mm (length) × 250 mm (width) × 200 mm (height) with a cast base 450 mm (length) × 450 mm (width) × 60 mm (height). A column, made from seamless drawn steel tube, is secured in a holder screwed on to the back of the steel block. Four screws anchor the apparatus to a solid concrete block 60 × 60 × 60 cm such that the guide rails are absolutely vertical and the drop weight falls freely. 5 and 10 kg weights, made from solid steel, are available for use. The striking head of each weight is of hardened steel, HRC 60 to 63, and has a minimum diameter of 25 mm.

The sample under test is enclosed in a shock device consisting of two coaxial solid steel cylinders, one above the other, in a hollow cylindrical steel guide ring. The solid steel cylinders should be of 10 (- 0,003, - 0,005) mm diameter and 10 mm height and have polished surfaces, rounded edges (radius of curvature 0,5 mm) and a hardness of HRC 58 to 65. The hollow cylinder must have an external diameter of 16 mm, a polished bore of 10 (+ 0,005, + 0,010) mm and a height of 13 mm. The shock device is assembled on an intermediate anvil (26 mm diameter and 26 mm height) made of steel and centred by a ring with perforations to allow escape of fumes.

1.6.2.2.   Test conditions

The sample volume should be 40 mm3, or a volume to suit any alternative apparatus. Solid substances should be tested in the dry state and prepared as follows:

(a) powdered substances are sieved (sieve size 0,5 mm); all that has passed through the sieve is used for testing;

(b) pressed, cast or otherwise condensed substances are broken into small pieces and sieved; the sieve fraction from 0,5 to 1 mm diameter is used for testing and should be representative of the original substance.

Substances normally supplied as pastes should be tested in the dry state where possible or, in any case, following removal of the maximum possible amount of diluent. Liquid substances are tested with a 1 mm gap between the upper and lower steel cylinders.

1.6.2.3.   Performance of the tests

A series of six tests are performed dropping the 10 kg mass from 0,40 m (40 J). If an explosion is obtained during the six tests at 40 J, a further series of six tests, dropping a 5 kg mass from 0,15 m (7,5 J), must be performed. In other apparatus, the sample is compared with the chosen reference substance using an established procedure (e.g. up-and-down technique etc.).

1.6.2.4.   Evaluation

The test result is considered positive if an explosion (bursting into flame and/or a report is equivalent to explosion) occurs at least once in any of the tests with the specified shock apparatus or the sample is more sensitive than 1,3-dinitrobenzene or RDX in an alternative shock test.

1.6.3.   Mechanical sensitivity (friction)

1.6.3.1.   Apparatus (figure 5)

The friction apparatus consists of a cast steel base plate on which is mounted the friction device. This consists of a fixed porcelain peg and moving porcelain plate. The porcelain plate is held in a carriage which runs in two guides. The carriage is connected to an electric motor via a connecting rod, an eccentric cam and suitable gearing such that the porcelain plate is moved, once only, back and forth beneath the porcelain peg for a distance of 10 mm. The porcelain peg may be loaded with, for example, 120 or 360 newtons.

The flat porcelain plates are made from white technical porcelain (roughness 9 to 32 μm) and have the dimensions 25 mm (length) × 25 mm (width) × 5 mm (height). The cylindrical porcelain peg is also made of white technical porcelain and is 15 mm long, has a diameter of 10 mm and roughened spherical end surfaces with a radius of curvature of 10 mm.

1.6.3.2.   Test conditions

The sample volume should be 10 mm3 or a volume to suit any alternative apparatus.

Solid substances are tested in the dry state and prepared as follows:

(a) powdered substances are sieved (sieve size 0,5 mm); all that has passed through the sieve is used for testing;

(b) pressed, cast or otherwise condensed substances are broken into small pieces and sieved; the sieve fraction < 0,5 mm diameter is used for testing.

Substances normally supplied as pastes should be tested in the dry state where possible. If the substance cannot be prepared in the dry state, the paste (following removal of the maximum possible amount of diluent) is tested as a 0,5 mm thick, 2 mm wide, 10 mm long film, prepared with a former.

1.6.3.3.   Performance of the tests

The porcelain peg is brought onto the sample under test and the load applied. When carrying out the test, the sponge marks of the porcelain plate must lie transversely to the direction of the movement. Care must be taken that the peg rests on the sample, that sufficient test material lies under the peg and also that the plate moves correctly under the peg. For pasty substances, a 0,5 mm thick gauge with a 2 × 10 mm slot is used to apply the substance to the plate. The porcelain plate has to move 10 mm forwards and backwards under the porcelain peg in a time of 0,44 seconds. Each part of the surface of the plate and peg must only be used once; the two ends of each peg will serve for two trials and the two surfaces of a plate will each serve for three trials.

A series of six tests are performed with a 360 N loading. If a positive event is obtained during these six tests, a further series of six tests must be performed with a 120 N loading. In other apparatus, the sample is compared with the chosen reference substance using an established procedure (e.g. up-and-down technique, etc.).

1.6.3.4.   Evaluation

The test result is considered positive if an explosion (crepitation and/or a report or bursting into flame are equivalent to explosion) occurs at least once in any of the tests with the specified friction apparatus or satisfies the equivalent criteria in an alternative friction test.

2.   DATA

In principle, a substance is considered to present a danger of explosion in the sense of the directive if a positive result is obtained in the thermal, shock or friction sensitivity test.

3.   REPORTING

3.1.   TEST REPORT

The test report shall, if possible, include the following information:

 identity, composition, purity, moisture content, etc. of the substance tested,

 the physical form of the sample and whether or not it has been crushed, broken and/or sieved,

 observations during the thermal sensitivity tests (e.g. sample mass, number of fragments, etc.),

 observations during the mechanical sensitivity tests (e.g. formation of considerable amounts of smoke or complete decomposition without a report, flames, sparks, report, crepitation, etc.),

 results of each type of test,

 if alternative apparatus has been used, scientific justification as well as evidence of correlation between results obtained with specified apparatus and those obtained with equivalent apparatus must be given,

 any useful comments such as reference to tests with similar products which might be relevant to a proper interpretation of the results,

 all additional remarks relevant for the interpretation of the results.

3.2.   INTERPRETATION AND EVALUATION OF RESULTS

The test report should mention any results which are considered false, anomalous or unrepresentative. If any of the results should be discounted, an explanation and the results of any alternative or supplementary testing should be given. Unless an anomalous result can be explained, it must be accepted at face value and used to classify the substance accordingly.

4.   REFERENCES

(1) Recommendations on the Transport of Dangerous Goods: Tests and criteria, 1990, United Nations, New York.

(2) Bretherick, L., Handbook of Reactive Chemical Hazards, 4th edition, Butterworths, London, ISBN 0-750-60103-5, 1990.

(3) Koenen, H., Ide, K.H. and Swart, K.H., Explosivstoffe, 1961, vol. 3, 6-13 and 30-42.

(4) NF T 20-038 (September 85) Chemical products for industrial use — Determination of explosion risk.

Appendix

Example of material specification for thermal sensitivity test (see DIN 1623)

(1) Tube: Material specification No 1.0336.505 g

(2) Orifice plate: Material specification No 1.4873

(3) Threaded collar and nut: Material specification No 1.3817

Figure 1

Thermal sensitivity test apparatus

(all dimensions in millimetres)

Fig. 1a Steel tube and accessories(1) tube(1a) outer flange(2) threaded collar; low-friction thread(3) orifice plate a = 2,0 or 6,0 mm diameter(4) nut b = 10 mm diameter(5) chamfered surface(6) 2 flat for spanner size 41Fig. 1b Heating and protective device(7) 2 flat for spanner size 36(8) splinter-proof box(9) 2 supporting rods for tube(10) assembled tube(11) position for rear burner; the other burners are visible(12) pilot jet

Figure 2

Thermal sensitivity test

(example of fragmentation)

No explosionNo explosionExplosionExplosionExplosionExplosion

Figure 3

Heating rate calibration for thermal sensitivity test

Temperature (°C)Time (s)

Temperature/time curve obtained on heating dibutyl phtalate (27 cm3) in a closed (1,5 mm orifice plate) tube using a propane flow rate of 3,2 litre/minute. The temperature is measured with a 1 mm diameter stainless steel sheathed chromel/alumel thermocouple, placed centrally 43 mm below the rim of the tube. The heating rate between 135 oC and 285 oC should be between 185 and 215 K/minute.

Figure 4

Shock test apparatus

(all dimensions in millimetres)

Fig. 4a Fall-hammer, front and side, general view(1) base, 450 x 450 x 60(2) steel block, 230 x 250 x 200(3) anvil, 100 diameter x 70(4) column(5) median cross-member(6) 2 guides(7) toothed rackFig. 4b Fall-hammer, lower part(8) graduated scale(9) fall-hammer (drop mass)(10) holding and releasing device(11) locating plate(12) intermediate anvil (interchangeable), 26 diameter x 26(13) locating ring with orifices(14) impact device

Figure 4

Continued

Fig. 4c Shock device for substances in powdered or paste-like formFig. 4d Shock device for liquid substances(1) steel cylinders(2) guide ring for steel cylinders(3) locating ring with orifices(a) vertical section(b) plan(4) rubber ring(5) liquid substance (40 mm3)(6) space free from liquidFig. 4e Hammer (drop mass of 5 kg)(1) suspension spigot(2) height marker(3) positioning groove(4) cylindrical striking head(5) rebound catch

Figure 5

Friction sensitivity apparatus

Fig. 5a Friction apparatus; elevation and plan view(1) steel base(2) movable carriage(3) porcelain plate, 25 x 25 x 5 mm, held on carriage(4) fixed porcelain peg, 10 diameter x 15 mm(5) sample under test, approximately 10 mm3Fig. 5b Starting position of peg on sample(6) peg-holder(7) loading arm(8) counterweight(9) switch(10) wheel for setting carriage at starting position(11) direction to electric drive motor

A.15.   AUTO-IGNITION TEMPERATURE (LIQUIDS AND GASES)

1.   METHOD

1.1.   INTRODUCTION

Explosive substances and substances which ignite spontaneously in contact with air at ambient temperature should not be submitted to this test. The test procedure is applicable to gases, liquids and vapours which, in the presence of air, can be ignited by a hot surface.

The auto-ignition temperature can be considerably reduced by the presence of catalytic impurities, by the surface material or by a higher volume of the test vessel.

1.2.   DEFINITIONS AND UNITS

The degree of auto-ignitability is expressed in terms of the auto-ignition temperature. The auto-ignition temperature is the lowest temperature at which the test substance will ignite when mixed with air under the conditions defined in the test method.

1.3.   REFERENCE SUBSTANCES

Reference substances are cited in the standards (see 1.6.3). They should primarily serve to check the performance of the method from time to time and to allow comparison with results from other methods.

1.4.   PRINCIPLE OF THE METHOD

The method determines the minimum temperature of the inner surface of an enclosure that will result in ignition of a gas, vapour or liquid injected into the enclosure.

1.5.   QUALITY CRITERIA

The repeatability varies according to the range of auto-ignition temperatures and the test method used.

The sensitivity and specificity depend on the test method used.

1.6.   DESCRIPTION OF THE METHOD

1.6.1.   Apparatus

The apparatus is described in the method referred to in 1.6.3.

1.6.2.   Test conditions

A sample of the test substance is tested according to the method referred to in 1.6.3.

1.6.3.   Performance of the test

See IEC 79-4, DIN 51794, ASTM-E 659-78, BS 4056, NF T 20-037.

2.   DATA

Record the test-temperature, atmospheric pressure, quantity of sample used and time-1ag until ignition occurs.

3.   REPORTING

The test report shall, if possible, include the following information:

 the precise specification of the substance (identification and impurities),

 the quantity of sample used, atmospheric pressure,

 the apparatus used,

 the results of measurements (test temperatures, results concerning ignition, corresponding time-lags),

 all additional remarks relevant to the interpretation of results.

4.   REFERENCES

None.

A.16.   RELATIVE SELF-IGNITION TEMPERATURE FOR SOLIDS

1.   METHOD

1.1.   INTRODUCTION

Explosive substances and substances which ignite spontaneously in contact with air at ambient temperature should not be submitted to this test.

The purpose of this test is to provide preliminary information on the auto-flammability of solid substances at elevated temperatures.

If the heat developed either by a reaction of the substance with oxygen or by exothermic decomposition is not lost rapidly enough to the surroundings, self-heating leading to self-ignition occurs. Self-ignition therefore occurs when the rate of heat-production exceeds the rate of heat loss.

The test procedure is useful as a preliminary screening test for solid substances. In view of the complex nature of the ignition and combustion of solids, the self-ignition temperature determined according to this test method should be used for comparison purposes only.

1.2.   DEFINITIONS AND UNITS

The self-ignition temperature as obtained by this method is the minimum ambient temperature expressed in oC at which a certain volume of a substance will ignite under defined conditions.

1.3.   REFERENCE SUBSTANCE

None.

1.4.   PRINCIPLE OF THE METHOD

A certain volume of the substance under test is placed in an oven at room temperature; the temperature/time curve relating to conditions in the centre of the sample is recorded while the temperature of the oven is increased to 400 oC, or to the melting point if lower, at a rate of 0,5oC/min. For the purpose of this test, the temperature of the oven at which the sample temperature reaches 400 oC by self-heating is called the self-ignition temperature.

1.5.   QUALITY CRITERIA

None.

1.6.   DESCRIPTION OF THE METHOD

1.6.1.   Apparatus

1.6.1.1.   Oven

A temperature-programmed laboratory oven (volume about 2 litres) fitted with natural air circulation and explosion relief. In order to avoid a potential explosion risk, any decomposition gases must not be allowed to come into contact with the electric heating elements.

1.6.1.2.   Wire mesh cube

A piece of stainless steel wire mesh with 0,045 mm openings should be cut according to the pattern in figure 1. The mesh should be folded and secured with wire into an open-topped cube.

1.6.1.3.   Thermocouples

Suitable thermocouples.

1.6.1.4.   Recorder

Any two-channel recorder calibrated from 0 to 600 oC or corresponding voltage.

1.6.2.   Test conditions

Substances are tested as received.

1.6.3.   Performance of the test

The cube is filled with the substance to be tested and is tapped gently, adding more of the substance until the cube is completely full. The cube is then suspended in the centre of the oven at room temperature. One thermocouple is placed at the centre of the cube and the other between the cube and the oven wall to record the oven temperature.

The temperatures of the oven and sample are continuously recorded while the temperature of the oven is increased to 400 oC, or to the melting point if lower, at a rate of 0,5oC/min.

When the substance ignites the sample thermocouple will show a very sharp temperature rise above the oven temperature.

2.   DATA

The temperature of the oven at which the sample temperature reaches 400 oC by self-heating is relevant for evaluation (see figure 2).

3.   REPORTING

The test report shall, if possible, include the following information:

 a description of the substance to be tested,

 the results of measurement including the temperature/time curve,

 all additional remarks relevant for the interpretation of the results.

4.   REFERENCES

NF T 20-036 (September 85) Chemical products for industrial use. Determination of the relative temperature of the spontaneous flammability of solids.

Figure 1

Pattern of 20 mm test cube

image

Figure 2

Typical temperature/time curve

sample temperatureoven temperatureignition temperatureTime

A.17.   OXIDISING PROPERTIES (SOLIDS)

1.   METHOD

1.1.   INTRODUCTION

It is useful to have preliminary information on any potentially explosive properties of the substance before performing this test.

This test is not applicable to liquids, gases, explosive or highly flammable substances, or organic peroxides.

This test need not be performed when examination of the structural formula establishes beyond reasonable doubt that the substance is incapable of reacting exothermically with a combustible material.

In order to ascertain if the test should be performed with special precautions, a preliminary test should be performed.

1.2.   DEFINITION AND UNITS

Burning time: reaction time, in seconds, taken for the reaction zone to travel along a pile, following the procedure described in 1.6.

Burning rate: expressed in millimetres per second.

Maximum burning rate: the highest value of the burning rates obtained with mixtures containing 10 to 90 % by weight of oxidiser.

1.3.   REFERENCE SUBSTANCE

Barium nitrate (analytical grade) is used as reference substance for the test and the preliminary test.

The reference mixture is that mixture of barium nitrate with powdered cellulose, prepared according to 1.6, which has the maximum burning rate (usually a mixture with 60 % barium nitrate by weight).

1.4.   PRINCIPLE OF THE METHOD

A preliminary test is carried out in the interests of safety. No further testing is required when the preliminary test clearly indicates that the test substance has oxidising properties. When this is not the case, the substance should then be subject to the full test.

In the full test, the substance to be tested and a defined combustible substance will be mixed in various ratios. Each mixture is then formed into a pile and the pile is ignited at one end. The maximum burning rate determined is compared with the maximum burning rate of the reference mixture.

1.5.   QUALITY CRITERIA

If required, any method of grinding and mixing is valid provided that the difference in the maximum rate of burning in the six separate tests differs from the arithmetic mean value by no more than 10 %.

1.6.   DESCRIPTION OF THE METHOD

1.6.1.   Preparation

1.6.1.1.   Test substance

Reduce the test sample to a particle size < 0,125 mm using the following procedure: sieve the test substance, grind the remaining fraction, repeat the procedure until the whole test portion has passed the sieve.

Any grinding and sieving method satisfying the quality criteria may be used.

Before preparing the mixture the substance is dried at 105 oC, until constant weight is obtained. If the decomposition temperature of the substance to be tested is below 105 oC, the substance has to be dried at a suitable lower temperature.

1.6.1.2.   Combustible substance

Powdered cellulose is used as a combustible substance. The cellulose should be a type used for thin-layer chromatography or column chromatography. A type with fibre-lengths of more than 85 % between 0,020 and 0,075 mm has proved to be suitable. The cellulose powder is passed through a sieve with a mesh-size of 0,125 mm. The same batch of cellulose is to be used throughout the test.

Before preparing the mixture, the powdered cellulose is dried at 105 oC until constant weight is obtained.

If wood-meal is used in the preliminary test, then prepare a soft-wood wood-meal by collecting the portion which passes through a sieve mesh of 1,6 mm, mix thoroughly, then dry at 105 oC for four hours in a layer not more than 25 mm thick. Cool and store in an air-tight container filled as full as practicable until required, preferably within 24 hours of drying.

1.6.1.3.   Ignition source

A hot flame from a gas burner (minimum diameter 5 mm) should be used as the ignition source. If another ignition source is used (e.g. when testing in an inert atmosphere), the description and the justification should be reported.

1.6.2.   Performance of the test

Note:

Mixtures of oxidisers with cellulose or wood-meal must be treated as potentially explosive and handled with due care.

1.6.2.1.   Preliminary test

The dried substance is thoroughly mixed with the dried cellulose or wood-meal in the proportions 2 of test substance to 1 of cellulose or wood-meal by weight and the mixture is formed into a small cone-shaped pile of dimensions 3,5 cm (diameter of base) × 2,5 cm (height) by filling, without tamping, a cone-shaped former (e.g. a laboratory glass funnel with the stem plugged).

The pile is placed on a cool, non-combustible, non-porous and low heat-conducting base plate. The test should be carried out in a fume cupboard as in 1.6.2.2.

The ignition source is put in contact with the cone. The vigour and duration of the resultant reaction are observed and recorded.

The substance is to be considered as oxidising if the reaction is vigorous.

In any case where the result is open to doubt, it is then necessary to complete the full train test described below.

1.6.2.2.   Train test

Prepare oxidiser cellulose-mixtures containing 10 to 90 % weight of oxidiser in 10 % increments. For borderline cases, intermediate oxidiser cellulose mixtures should be used to obtain the maximum burning rate more precisely.

The pile is formed by means of a mould. The mould is made of metal, has a length of 250 mm and a triangular cross-section with an inner height of 10 mm and an inner width of 20 mm. On both sides of the mould, in the longitudinal direction, two metal plates are mounted as lateral limitations which project 2 mm beyond the upper edge of the triangular cross-section (figure). This arrangement is loosely filled with a slight excess of mixture. After dropping the mould once from a height of 2 cm onto a solid surface, the remaining excess substance is scraped off with an obliquely positioned sheet. The lateral limitations are removed and the remaining powder is smoothed, using a roller. A non-combustible, non-porous and low heat-conducting base plate is then placed on the top of the mould, the apparatus inverted and the mould removed.

Arrange the pile across the draught in a fume cupboard.

The air-speed should be sufficient to prevent fumes escaping into the laboratory and should not be varied during the test. A draught screen should be erected around the apparatus.

Due to hygroscopicity of cellulose and of some substances to be tested, the test should be carried out as quickly as possible.

Ignite one end of the pile by touching with the flame.

Measure the time of reaction over a distance of 200 mm after the reaction zone has propagated an initial distance of 30 mm.

The test is performed with the reference substance and at least once with each one of the range of mixtures of the test substance with cellulose.

If the maximum burning rate is found to be significantly greater than that from the reference mixture, the test can be stopped; otherwise the test should be repeated five times for each of the three mixtures giving the fastest burning rate.

If the result is suspected of being a false positive, then the test should be repeated using an inert substance with a similar particle size, such as kieselguhr, in place of cellulose. Alternatively, the test substance cellulose mixture, having the fastest burning rate, should be retested in an inert atmosphere (< 2 % v/v oxygen content).

2.   DATA

For safety reasons the maximum burning rate — not the mean value — shall be considered to be the characteristic oxidising property of the substance under test.

The highest value of burning rate within a run of six tests of a given mixture is relevant for evaluation.

Plot a graph of the highest value of burning rate for each mixture versus the oxidiser concentration. From the graph take the maximum burning rate.

The six measured values of burning rate within a run obtained from the mixture with the maximum burning rate must not differ from the arithmetic mean value by more than 10 %; otherwise the methods of grinding and mixing must be improved.

Compare the maximum burning rate obtained with the maximum burning rate of the reference mixture (see 1.3).

If tests are conducted in an inert atmosphere, the maximum reaction rate is compared with that from the reference mixture in an inert atmosphere.

3.   REPORT

3.1.   TEST REPORT

The test report shall, if possible, include the following information:

 the identity, composition, purity, moisture content etc. of the substance tested,

 any treatment of the test sample (e.g. grinding, drying),

 the ignition source used in the tests,

 the results of measurements,

 the mode of reaction (e.g. flash burning at the surface, burning through the whole mass, any information concerning the combustion products, etc.),

 all additional remarks relevant for the interpretation of results, including a description of the vigour (flaming, sparking, fuming, slow smouldering, etc.) and approximate duration produced in the preliminary safety/screening test for both test and reference substance,

 the results from tests with an inert substance, if any,

 the results from tests in an inert atmosphere, if any.

3.2.   INTERPRETATION OF THE RESULT

A substance is to be considered as an oxidising substance when:

(a) in the preliminary test, there is a vigorous reaction;

(b) in the full test, the maximum burning rate of the mixtures tested is higher than or equal to the maximum burning rate of the reference mixture of cellulose and barium nitrate.

In order to avoid a false positive, the results obtained when testing the substance mixed with an inert material and/or when testing under an inert atmosphere should also be considered when interpreting the results.

4.   REFERENCES

NF T 20-035 (September 85) Chemical products for industrial use. Determination of the oxidising properties of solids.

Appendix

Figure

Mould and accessories for the preparations of the pile

(All dimensions in millimetres)

image

A.18.   NUMBER-AVERAGE MOLECULAR WEIGHT AND MOLECULAR WEIGHT DISTRIBUTION OF POLYMERS

1.   METHOD

This Gel Permeation Chromatographic method is a replicate of the OECD TG 118 (1996). The fundamental principles and further technical information are given in reference (1).

1.1.   INTRODUCTION

Since the properties of polymers are so varied, it is impossible to describe one single method setting out precisely the conditions for separation and evaluation which cover all eventualities and specificities occurring in the separation of polymers. In particular, complex polymer systems are often not amenable to gel permeation chromatography (GPC). When GPC is not practicable, the molecular weight may be determined by means of other methods (see Appendix). In such cases, full details and justification should be given for the method used.

The method described is based on DIN Standard 55672 (1). Detailed information about how to carry out the experiments and how to evaluate the data can be found in this DIN Standard. In case modifications of the experimental conditions are necessary, these changes must be justified. Other standards may be used, if fully referenced. The method described uses polystyrene samples of known polydispersity for calibration and it may have to be modified to be suitable for certain polymers, e.g. water soluble and long-chain branched polymers.

1.2.   DEFINITIONS AND UNITS

The number-average molecular weight Mn and the weight average molecular weight Mw are determined using the following equations:



image

image

where,

Hi is the level of the detector signal from the baseline for the retention volume Vi,

Mi is the molecular weight of the polymer fraction at the retention volume Vi, and

n is the number of data points.

The breadth of the molecular weight distribution, which is a measure of the dispersity of the system, is given by the ratio Mw/Mn.

1.3.   REFERENCE SUBSTANCES

Since GPC is a relative method, calibration must be undertaken. Narrowly distributed, linearly constructed polystyrene standards with known average molecular weights Mn and Mw and a known molecular weight distribution are normally used for this. The calibration curve can only be used in the determination of the molecular weight of the unknown sample if the conditions for the separation of the sample and the standards have been selected in an identical manner.

A determined relationship between the molecular weight and elution volume is only valid under the specific conditions of the particular experiment. The conditions include, above all, the temperature, the solvent (or solvent mixture), the chromatography conditions and the separation column or system of columns.

The molecular weights of the sample determined in this way are relative values and are described as ‘polystyrene equivalent molecular weights’. This means that dependent on the structural and chemical differences between the sample and the standards, the molecular weights can deviate from the absolute values to a greater or a lesser degree. If other standards are used, e.g. polyethylene glycol, polyethylene oxide, polymethyl methacrylate, polyacrylic acid, the reason should be stated.

1.4.   PRINCIPLE OF THE TEST METHOD

Both the molecular weight distribution of the sample and the average molecular weights (Mn, Mw) can be determined using GPC. GPC is a special type of liquid chromatography in which the sample is separated according to the hydrodynamic volumes of the individual constituents (2).

Separation is effected as the sample passes through a column which is filled with a porous material, typically an organic gel. Small molecules can penetrate the pores whereas large molecules are excluded. The path of the large molecules is thereby shorter and these are eluted first. The medium-sized molecules penetrate some of the pores and are eluted later. The smallest molecules, with a mean hydrodynamic radius smaller than the pores of the gel, can penetrate all of the pores. These are eluted last.

In an ideal situation, the separation is governed entirely by the size of the molecular species, but in practice it is difficult to avoid at least some absorption effects interfering. Uneven column packing and dead volumes can worsen the situation (2).

Detection is effected by, e.g. refractive index or UV-absorption, and yields a simple distribution curve. However, to attribute actual molecular weight values to the curve, it is necessary to calibrate the column by passing down polymers of known molecular weight and, ideally, of broadly similar structure e.g. various polystyrene standards. Typically a Gaussian curve results, sometimes distorted by a small tail to the low molecular weight side, the vertical axis indicating the quantity, by weight, of the various molecular weight species eluted, and the horizontal axis the log molecular weight.

1.5.   QUALITY CRITERIA

The repeatability (Relative Standard Deviation: RSD) of the elution volume should be better than 0,3 %. The required repeatability of the analysis has to be ensured by correction via an internal standard if a chromatogram is evaluated time-dependently and does not correspond to the above mentioned criterion (1). The polydispersities are dependent on the molecular weights of the standards. In the case of polystyrene standards typical values are:



Mp < 2 000

Mw/Mn < 1,20

2 000 ≤ Mp ≤ 106

Mw/Mn < 1,05

Mp > 106

Mw/Mn < 1,20

(Mp is the molecular weight of the standard at the peak maximum)

1.6.   DESCRIPTION OF THE TEST METHOD

1.6.1.   Preparation of the standard polystyrene solutions

The polystyrene standards are dissolved by careful mixing in the chosen eluent. The recommendations of the manufacturer must be taken into account in the preparation of the solutions.

The concentrations of the standards chosen are dependent on various factors, e.g. injection volume, viscosity of the solution and sensitivity of the analytical detector. The maximum injection volume must be adapted to the length of the column, in order to avoid overloading. Typical injection volumes for analytical separations using GPC with a column of 30 cm × 7,8 mm are normally between 40 and 100 μl. Higher volumes are possible, but they should not exceed 250 μl. The optimal ratio between the injection volume and the concentration must be determined prior to the actual calibration of the column.

1.6.2.   Preparation of the sample solution

In principle, the same requirements apply to the preparation of the sample solutions. The sample is dissolved in a suitable solvent, e.g. tetrahydrofuran (THF), by shaking carefully. Under no circumstances should it be dissolved using an ultrasonic bath. When necessary, the sample solution is purified via a membrane filter with a pore size of between 0,2 and 2 μm.

The presence of undissolved particles must be recorded in the final report as these may be due to high molecular weight species. An appropriate method should be used to determine the percentage by weight of the undissolved particles. The solutions should be used within 24 hours.

1.6.3.   Apparatus

 solvent reservoir,

 degasser (where appropriate),

 pump,

 pulse dampener (where appropriate),

 injection system,

 chromatography columns,

 detector,

 flowmeter (where appropriate),

 data recorder-processor,

 waste vessel.

It must be ensured that the GPC system is inert with regard to the utilised solvents (e.g. by the use of steel capillaries for THF solvent).

1.6.4.   Injection and solvent delivery system

A defined volume of the sample solution is loaded onto the column either using an auto-sampler or manually in a sharply defined zone. Withdrawing or depressing the plunger of the syringe too quickly, if done manually, can cause changes in the observed molecular weight distribution. The solvent-delivery system should, as far as possible, be pulsation-free ideally incorporating a pulse dampener. The flow rate is of the order of 1 ml/min.

1.6.5.   Column

Depending on the sample, the polymer is characterised using either a simple column or several columns connected in sequence. A number of porous column materials with defined properties (e.g. pore size, exclusion limits) are commercially available. Selection of the separation gel or the length of the column is dependent on both the properties of the sample (hydrodynamic volumes, molecular weight distribution) and the specific conditions for separation such as solvent, temperature and flow rate (1)(2)(3).

1.6.6.   Theoretical plates

The column or the combination of columns used for separation must be characterised by the number of theoretical plates. This involves, in the case of THF as elution solvent, loading a solution of ethyl benzene or other suitable non-polar solute onto a column of known length. The number of theoretical plates is given by the following equation:



image

or

image

where,

N

=

the number of theoretical plates

Ve

=

the elution volume at the peak maximum

W

=

the baseline peak width

W1/2

=

the peak width at half height

1.6.7.   Separation efficiency

In addition to the number of theoretical plates, which is a quantity determining the bandwidth, a part is also played by the separation efficiency, this being determined by the steepness of the calibration curve. The separation efficiency of a column is obtained from the following relationship:

image

where,

Ve, Mx

=

the elution volume for polystyrene with the molecular weight Mx

Ve,(10.Mx)

=

the elution volume for polystyrene with a ten times greater molecular weight

The resolution of the system is commonly defined as follows:

image

where,

Ve1, Ve2

=

the elution volumes of the two polystyrene standards at the peak maximum

W1, W2

=

the peak widths at the base-line

M1, M2

=

the molecular weights at the peak maximum (should differ by a factor of 10)

The R-value for the column system should be greater than 1.7 (4).

1.6.8.   Solvents

All solvents must be of high purity (for THF purity of 99,5 % is used). The solvent reservoir (if necessary in an inert gas atmosphere) must be sufficiently large for the calibration of the column and several sample analyses. The solvent must be degassed before it is transported to the column via the pump.

1.6.9.   Temperature control

The temperature of the critical internal components (injection loop, columns, detector and tubing) should be constant and consistent with the choice of solvent.

1.6.10.   Detector

The purpose of the detector is to record quantitatively the concentration of sample eluted from the column. In order to avoid unnecessary broadening of peaks the cuvette volume of the detector cell must be kept as small as possible. It should not be larger than 10 μl except for light scattering and viscosity detectors. Differential refractometry is usually used for detection. However, if required by the specific properties of the sample or the elution solvent, other types of detectors can be used, e.g. UV/VIS, IR, viscosity detectors, etc.

2.   DATA AND REPORTING

2.1.   DATA

The DIN Standard (1) should be referred to for the detailed evaluation criteria as well as for the requirements relating to the collecting and processing of data.

For each sample, two independent experiments must be carried out. They have to be analysed individually.

Mn, Mw, Mw/Mn and Mp must be provided for every measurement. It is necessary to indicate explicitly that the measured values are relative values equivalent to the molecular weights of the standard used.

After determination of the retention volumes or the retention times (possibly corrected using an internal standard), log Mp values (Mp being the peak maxima of the calibration standard) are plotted against one of those quantities. At least two calibration points are necessary per molecular weight decade, and at least five measurement points are required for the total curve, which should cover the estimated molecular weight of the sample. The low molecular weight end-point of the calibration curve is defined by n-hexyl benzene or another suitable non-polar solute. The number average and the weight-average molecular weights are generally determined by means of electronic data processing, based on the formulas of section 1.2. In case manual digitisation is used, ASTM D 3536-91 can be consulted (3).

The distribution curve must be provided in the form of a table or as figure (differential frequency or sum percentages against log M). In the graphic representation, one molecular weight decade should be normally about 4 cm in width and the peak maximum should be about 8 cm in height. In the case of integral distribution curves the difference in the ordinate between 0 and 100 % should be about 10 cm.

2.2.   TEST REPORT

The test report must include the following information:

2.2.1.   Test substance:

 available information about test substance (identity, additives, impurities),

 description of the treatment of the sample, observations, problems.

2.2.2.   Instrumentation:

 reservoir of eluent, inert gas, degassing of the eluent, composition of the eluent, impurities,

 pump, pulse dampener, injection system,

 separation columns (manufacturer, all information about the characteristics of the columns, such as pore size, kind of separation material, etc., number, length and order of the columns used),

 number of the theoretical plates of the column (or combination), separation efficiency (resolution of the system),

 information on symmetry of the peaks,

 column temperature, kind of temperature control,

 detector (measurement principle, type, cuvette volume),

 flowmeter if used (manufacturer, measurement principle),

 system to record and process data (hardware and software).

2.2.3.   Calibration of the system:

 detailed description of the method used to construct the calibration curve,

 information about quality criteria for this method (e.g. correlation coefficient, error sum of squares, etc.),

 information about all extrapolations, assumptions and approximations made during the experimental procedure and the evaluation and processing of data,

 all measurements used for constructing the calibration curve have to be documented in a table which includes the following information for each calibration point:

 

 name of the sample,

 manufacturer of the sample,

 characteristic values of the standards Mp, Mn, Mw, Mw/Mn, as provided by the manufacturer or derived by subsequent measurements, together with details about the method of determination,

 injection volume and injection concentration,

 Mp value used for calibration,

 elution volume or corrected retention time measured at the peak maxima,

 Mp calculated at the peak maximum,

 percentage error of the calculated Mp and the calibration value.

2.2.4.   Evaluation:

 evaluation on a time basis: methods used to ensure the required reproducibility (method of correction, internal standard, etc.),

 information about whether the evaluation was effected on the basis of the elution volume or the retention time,

 information about the limits of the evaluation if a peak is not completely analysed,

 description of smoothing methods, if used,

 preparation and pre-treatment procedures of the sample,

 the presence of undissolved particles, if any,

 injection volume (μl) and injection concentration (mg/ml),

 observations indicating effects which lead to deviations from the ideal GPC profile,

 detailed description of all modifications in the testing procedures,

 details of the error ranges,

 any other information and observations relevant for the interpretation of the results.

3.   REFERENCES

(1) DIN 55672(1995) Gelpermeationschromatographie (GPC) mit Tetrahydrofuran (THF) als Elutionsmittel, Teil 1.

(2) Yau, W.W., Kirkland, J.J., and Bly, D.D. eds., (1979) Modern Size Exclusion Liquid Chromatography, J. Wiley and Sons.

(3) ASTM D 3536-91, (1991). Standard Test Method for Molecular Weight Averages and Molecular Weight Distribution by Liquid Exclusion Chromatography (Gel Permeation Chromatography-GPC) American Society for Testing and Materials, Philadelphia, Pennsylvania.

(4) ASTM D 5296-92, (1992) Standard Test Method for Molecular Weight Averages and Molecular Weight Distribution of Polystyrene by High Performance Size-Exclusion Chromatography. American Society for Testing and Materials, Philadelphia, Pennsylvania.

Appendix

Examples of other methods for determination of number average molecular weight (Mn) for polymers

Gel permeation chromatography (GPC) is the preferred method for determination of Mn, especially when a set of standards are available, whose structure are comparable with the polymer structure. However, where there are practical difficulties in using GPC or there is already an expectation that the substance will fail a regulatory Mn criterion (and which needs confirming), alternative methods are available, such as:

1.   Use of colligative properties

1.1. Ebullioscopy/Cryoscopy

involves measurement of boiling point elevation (ebullioscopy) or freezing point depression (cryoscopy) of a solvent, when the polymer is added. The method relies on the fact that the effect of the dissolved polymer on the boiling/freezing point of the liquid is dependent on the molecular weight of the polymer (1) (2).

Applicability, Mn < 20 000.

1.2. Lowering of vapour pressure

involves the measurement of the vapour pressure of a chosen reference liquid before and after the addition of known quantities of polymer (1) (2).

Applicability, Mn < 20 000 (theoretically; in practice however of limited value).

1.3 Membrane osmometry

relies on the principle of osmosis, i.e. the natural tendency of solvent molecules to pass through a semi-permeable membrane from a dilute to a concentrated solution to achieve equilibrium. In the test, the dilute solution is at zero concentration, whereas the concentrated solution contains the polymer. The effect of drawing solvent through the membrane causes a pressure differential that is dependent on the concentration and the molecular weight of the polymer (1) (3) (4).

Applicability, Mn between 20 000 - 200 000.

1.4 Vapour phase osmometry

involves comparison of the rate of evaporation of a pure solvent aerosol to at least three aerosols containing the polymer at different concentrations (1)(2)(4).

Applicability, Mn < 20 000.

2.   End-group analysis

To use this method, knowledge of both the overall structure of the polymer and the nature of the chain terminating end groups is needed (which must be distinguishable from the main skeleton by, e.g. NMR or titration/derivatisation). The determination of the molecular concentration of the end groups present on the polymer can lead to a value for the molecular weight (7) (8) (9).

Applicability, Mn up to 50 000 (with decreasing reliability).

3.   References

(1) Billmeyer, F.W. Jr., (1984) Textbook of Polymer Science, 3rd Edn., John Wiley, New York.

(2) Glover, C.A., (1975) Absolute Colligative Property Methods. Chapter 4. In: Polymer Molecular Weights, Part I P.E. Slade, Jr. ed., Marcel Dekker, New York.

(3) ASTM D 3750-79, (1979) Standard Practice for Determination of Number-Average Molecular Weight of Polymers by Membrane Osmometry. American Society for Testing and Materials, Philadelphia, Pennsylvania.

(4) Coll, H. (1989) Membrane Osmometry. In: Determination of Molecular Weight, A.R. Cooper ed., J. Wiley and Sons, pp. 25-52.

(5) ASTM 3592-77, (1977) Standard Recommended Practice for Determination of Molecular Weight by Vapour Pressure, American Society for Testing and Materials, Philadelphia, Pennsylvania.

(6) Morris, C.E.M., (1989) Vapour Pressure Osmometry. In: Determinationn of Molecular Weight, A.R. Cooper ed., John Wiley and Sons.

(7) Schröder, E., Müller, G., and Arndt, K-F., (1989) Polymer Characterisation, Carl Hanser Verlag, Munich.

(8) Garmon, R.G., (1975) End-Group Determinations, Chapter 3 In: Polymer Molecular Weights, Part I, P.E. Slade, Jr. ed., Marcel Dekker, New York.

(9) Amiya, S., et al. (1990) Pure and Applied Chemistry, 62, 2139-2146.

A.19.   LOW MOLECULAR WEIGHT CONTENT OF POLYMERS

1.   METHOD

This Gel Permeation Chromatographic method is a replicate of the OECD TG 119 (1996). The fundamental principles and further technical information are given in the references.

1.1.   INTRODUCTION

Since the properties of polymers are so varied, it is impossible to describe one single method setting out precisely the conditions for separation and evaluation which cover all eventualities and specificities occurring in the separation of polymers. In particular, complex polymer systems are often not amenable to gel permeation chromatography (GPC). When GPC is not practicable, the molecular weight may be determined by means of other methods (see Appendix). In such cases, full details and justification should be given for the method used.

The method described is based on DIN Standard 55672 (1). Detailed information about how to carry out the experiments and how to evaluate the data can be found in this DIN Standard. In case modifications of the experimental conditions are necessary, these changes must be justified. Other standards may be used, if fully referenced. The method described uses polystyrene samples of known polydispersity for calibration and it may have to be modified to be suitable for certain polymers, e.g. water soluble and long-chain branched polymers.

1.2.   DEFINITIONS AND UNITS

Low molecular weight is arbitrarily defined as a molecular weight below 1 000 dalton.

The number-average molecular weight Mn and the weight average molecular weight Mw are determined using the following equations:



image

image

where,

Hi

=

the level of the detector signal from the baseline for the retention volume Vi,

Mi

=

the molecular weight of the polymer fraction at the retention volume Vi, and n is the number of data points

The breadth of the molecular weight distribution, which is a measure of the dispersity of the system, is given by the ratio Mw/Mn.

1.3.   REFERENCE SUBSTANCES

Since GPC is a relative method, calibration must be undertaken. Narrowly distributed, linearly constructed polystyrene standards with known average molecular weights Mn and Mw and a known molecular weight distribution are normally used for this. The calibration curve can only be used in the determination of the molecular weight of the unknown sample if the conditions for the separation of the sample and the standards have been selected in an identical manner.

A determined relationship between the molecular weight and elution volume is only valid under the specific conditions of the particular experiment. The conditions include, above all, the temperature, the solvent (or solvent mixture), the chromatography conditions and the separation column or system of columns.

The molecular weights of the sample determined in this way are relative values and are described as ‘polystyrene equivalent molecular weights’. This means that dependent on the structural and chemical differences between the sample and the standards, the molecular weights can deviate from the absolute values to a greater or a lesser degree. If other standards are used, e.g. polyethylene glycol, polyethylene oxide, polymethyl methacrylate, polyacrylic acid, the reason should be stated.

1.4.   PRINCIPLE OF THE TEST METHOD

Both the molecular weight distribution of the sample and the average molecular weights (Mn, Mw) can be determined using GPC. GPC is a special type of liquid chromatography in which the sample is separated according to the hydrodynamic volumes of the individual constituents (2).

Separation is effected as the sample passes through a column which is filled with a porous material, typically an organic gel. Small molecules can penetrate the pores whereas large molecules are excluded. The path of the large molecules is thereby shorter and these are eluted first. The medium-sized molecules penetrate some of the pores and are eluted later. The smallest molecules, with a mean hydrodynamic radius smaller than the pores of the gel, can penetrate all of the pores. These are eluted last.

In an ideal situation, the separation is governed entirely by the size of the molecular species, but in practice it is difficult to avoid at least some absorption effects interfering. Uneven column packing and dead volumes can worsen the situation (2).

Detection is effected by e.g. refractive index or UV-absorption and yields a simple distribution curve. However, to attribute actual molecular weight values to the curve, it is necessary to calibrate the column by passing down polymers of known molecular weight and, ideally, of broadly similar structure, e.g. various polystyrene standards. Typically a Gaussian curve results, sometimes distorted by a small tail to the low molecular weight side, the vertical axis indicating the quantity, by weight, of the various molecular weight species eluted, and the horizontal axis the log molecular weight.

The low molecular weight content is derived from this curve. The calculation can only be accurate if the low molecular weight species respond equivalently on a per mass basis to the polymer as a whole.

1.5.   QUALITY CRITERIA

The repeatability (Relative Standard Deviation: RSD) of the elution volume should be better than 0,3 %. The required repeatability of the analysis has to be ensured by correction via an internal standard if a chromatogram is evaluated time-dependently and does not correspond to the above mentioned criterion (1). The polydispersities are dependent on the molecular weights of the standards. In the case of polystyrene standards typical values are:



Mp < 2 000

Mw/Mn < 1,20

2 000< Mp < 106

Mw/Mn < 1,05

Mp > 106

Mw/Mn < 1,20

(Mp is the molecular weight of the standard at the peak maximum)

1.6.   DESCRIPTION OF THE TEST METHOD

1.6.1.   Preparation of the standard polystyrene solutions

The polystyrene standards are dissolved by careful mixing in the chosen eluent. The recommendations of the manufacturer must be taken into account in the preparation of the solutions.

The concentrations of the standards chosen are dependent on various factors, e.g. injection volume, viscosity of the solution and sensitivity of the analytical detector. The maximum injection volume must be adapted to the length of the column, in order to avoid overloading. Typical injection volumes for analytical separations using GPC with a column of 30 cm × 7,8 mm are normally between 40 and 100 μl. Higher volumes are possible, but they should not exceed 250 μl. The optimal ratio between the injection volume and the concentration must be determined prior to the actual calibration of the column.

1.6.2.   Preparation of the sample solution

In principle, the same requirements apply to the preparation of the sample solutions. The sample is dissolved in a suitable solvent, e.g. tetrahydrofuran (THF), by shaking carefully. Under no circumstances should it be dissolved using an ultrasonic bath. When necessary, the sample solution is purified via a membrane filter with a pore size of between 0,2 and 2 μm.

The presence of undissolved particles must be recorded in the final report as these may be due to high molecular weight species. An appropriate method should be used to determine the percentage by weight of the undissolved particles. The solutions should be used within 24 hours.

1.6.3.   Correction for content of impurities and additives

Correction of the content of species of M < 1 000 for the contribution from non-polymer specific components present (e.g. impurities and/or additives) is usually necessary, unless the measured content is already < 1 %. This is achieved by direct analysis of the polymer solution or the GPC eluate.

In cases where the eluate, after passage through the column, is too dilute for a further analysis it must be concentrated. It may be necessary to evaporate the eluate to dryness and dissolve it again. Concentration of the eluate must be effected under conditions which ensure that no changes occur in the eluate. The treatment of the eluate after the GPC step is dependent on the analytical method used for the quantitative determination.

1.6.4.   Apparatus

GPC apparatus comprises the following components:

 solvent reservoir,

 degasser (where appropriate),

 pump,

 pulse dampener (where appropriate),

 injection system,

 chromatography columns,

 detector,

 flowmeter (where appropriate),

 data recorder-processor,

 waste vessel.

It must be ensured that the GPC system is inert with regard to the utilised solvents (e.g. by the use of steel capillaries for THF solvent).

1.6.5.   Injection and solvent delivery system

A defined volume of the sample solution is loaded onto the column either using an auto-sampler or manually in a sharply defined zone. Withdrawing or depressing the plunger of the syringe too quickly, if done manually, can cause changes in the observed molecular weight distribution. The solvent-delivery system should, as far as possible, be pulsation-free ideally incorporating a pulse dampener. The flow rate is of the order of 1 ml/min.

1.6.6.   Column

Depending on the sample, the polymer is characterised using either a simple column or several columns connected in sequence. A number of porous column materials with defined properties (e.g. pore size, exclusion limits) are commercially available. Selection of the separation gel or the length of the column is dependent on both the properties of the sample (hydrodynamic volumes, molecular weight distribution) and the specific conditions for separation such as solvent, temperature and flow rate (1) (2) (3).

1.6.7.   Theoretical plates

The column or the combination of columns used for separation must be characterised by the number of theoretical plates. This involves, in the case of THF as elution solvent, loading a solution of ethyl benzene or other suitable non-polar solute onto a column of known length. The number of theoretical plates is given by the following equation:



image

or

image

where,

N

=

the number of theoretical plates

Ve

=

the elution volume at the peak maximum

W

=

the baseline peak width

W1/2

=

the peak width at half height

1.6.8.   Separation efficiency

In addition to the number of theoretical plates, which is a quantity determining the bandwidth, a part is also played by the separation efficiency, this being determined by the steepness of the calibration curve. The separation efficiency of a column is obtained from the following relationship:

image

where,

Ve, Mx

=

the elution volume for polystyrene with the molecular weight Mx

Ve,(10.Mx)

=

the elution volume for polystyrene with a ten times greater molecular weight

The resolution of the system is commonly defined as follows:

image

where,

Ve1, Ve2

=

the elution volumes of the two polystyrene standards at the peak maximum

W1, W2

=

the peak widths at the base-1ine

M1, M2

=

the molecular weights at the peak maximum (should differ by a factor of 10).

The R-value for the column system should be greater than 1,7 (4).

1.6.9.   Solvents

All solvents must be of high purity (for THF purity of 99,5 % is used). The solvent reservoir (if necessary in an inert gas atmosphere) must be sufficiently large for the calibration of the column and several sample analyses. The solvent must be degassed before it is transported to the column via the pump.

1.6.10.   Temperature control

The temperature of the critical internal components (injection loop, columns, detector and tubing) should be constant and consistent with the choice of solvent.

1.6.11.   Detector

The purpose of the detector is to record quantitatively the concentration of sample eluted from the column. In order to avoid unnecessary broadening of peaks the cuvette volume of the detector cell must be kept as small as possible. It should not be larger than 10 μl except for light scattering and viscosity detectors. Differential refractometry is usually used for detection. However, if required by the specific properties of the sample or the elution solvent, other types of detectors can be used, e.g. UV/VIS, IR, viscosity detectors, etc.

2.   DATA AND REPORTING

2.1.   DATA

The DIN Standard (1) should be referred to for the detailed evaluation criteria as well as for the requirements relating to the collecting and processing of data.

For each sample, two independent experiments must be carried out. They have to be analysed individually. In all cases it is essential to determine also data from blanks, treated under the same conditions as the sample.

It is necessary to indicate explicitly that the measured values are relative values equivalent to the molecular weights of the standard used.

After determination of the retention volumes or the retention times (possibly corrected using an internal standard), log Mp values (Mp being the peak maxima of the calibration standard) are plotted against one of those quantities. At least two calibration points are necessary per molecular weight decade, and at least five measurement points are required for the total curve, which should cover the estimated molecular weight of the sample. The low molecular weight end-point of the calibration curve is defined by n-hexyl benzene or another suitable non-polar solute. The portion of the curve corresponding to molecular weights below 1 000 is determined and corrected as necessary for impurities and additives. The elution curves are generally evaluated by means of electronic data processing. In case manual digitisation is used, ASTM D 3536-91 can be consulted (3).

If any insoluble polymer is retained on the column, its molecular weight is likely to be higher than that of the soluble fraction, and if not considered would result in an overestimation of the low molecular weight content. Guidance for correcting the low molecular weight content for insoluble polymer is provided in the Appendix.

The distribution curve must be provided in the form of a table or as figure (differential frequency or sum percentages against log M). In the graphic representation, one molecular weight decade should be normally about 4 cm in width and the peak maximum should be about 8 cm in height. In the case of integral distribution curves the difference in the ordinate between 0 and 100 % should be about 10 cm.

2.2.   TEST REPORT

The test report must include the following information:

2.2.1.   Test substance:

 available information about test substance (identity, additives, impurities),

 description of the treatment of the sample, observations, problems.

2.2.2.   Instrumentation:

 reservoir of eluent, inert gas, degassing of the eluent, composition of the eluent, impurities,

 pump, pulse dampener, injection system,

 separation columns (manufacturer, all information about the characteristics of the columns, such as pore size, kind of separation material, etc., number, length and order of the columns used),

 number of the theoretical plates of the column (or combination), separation efficiency (resolution of the system),

 information on symmetry of the peaks,

 column temperature, kind of temperature control,

 detector (measurement principle, type, cuvette volume),

 flowmeter if used (manufacturer, measurement principle),

 system to record and process data (hardware and software).

2.2.3.   Calibration of the system:

 detailed description of the method used to construct the calibration curve,

 information about quality criteria for this method (e.g. correlation coefficient, error sum of squares, etc.),

 information about all extrapolations, assumptions and approximations made during the experimental procedure and the evaluation and processing of data,

 all measurements used for constructing the calibration curve have to be documented in a table which includes the following information for each calibration point:

 

 name of the sample,

 manufacturer of the sample,

 characteristic values of the standards Mp, Mn, Mw, Mw/Mn, as provided by the manufacturer or derived by subsequent measurements, together with details about the method of determination,

 injection volume and injection concentration,

 Mp value used for calibration,

 elution volume or corrected retention time measured at the peak maxima,

 Mp calculated at the peak maximum,

 percentage error of the calculated Mp and the calibration value.

2.2.4.   Information on the low molecular weight polymer content:

 description of the methods used in the analysis and the way in which the experiments were conducted,

 information about the percentage of the low molecular weight species content (w/w) related to the total sample,

 information about impurities, additives and other non-polymer species in percentage by weight related to the total sample.

2.2.5.   Evaluation:

 evaluation on a time basis: all methods to ensure the required reproducibility (method of correction, internal standard etc.),

 information about whether the evaluation was effected on the basis of the elution volume or the retention time,

 information about the limits of the evaluation if a peak is not completely analysed,

 description of smoothing methods, if used,

 preparation and pre-treatment procedures of the sample,

 the presence of undissolved particles, if any,

 injection volume (μl) and injection concentration (mg/ml),

 observations indicating effects which lead to deviations from the ideal GPC profile,

 detailed description of all modifications in the testing procedures,

 details of the error ranges,

 any other information and observations relevant for the interpretation of the results.

3.   REFERENCES

(1) DIN 55672 (1995) Gelpermeationschromatographie (GPC) mit Tetrahydrofuran (THF) als Elutionsmittel, Teil 1.

(2) Yau, W.W., Kirkland, J.J., and Bly, D.D. eds. (1979) Modern Size Exclusion Liquid Chromatography, J. Wiley and Sons.

(3) ASTM D 3536-91, (1991) Standard Test method for Molecular Weight Averages and Molecular Weight Distribution by Liquid Exclusion Chromatography (Gel Permeation Chromatography-GPC). American Society for Testing and Materials, Philadelphia, Pennsylvania.

(4) ASTM D 5296-92, (1992) Standard Test method for Molecular Weight Averages and Molecular Weight Distribution of Polystyrene by High Performance Size-Exclusion Chromatography. American Society for Testing and Materials, Philadelphia, Pennsylvania.

Appendix

Guidance for correcting low molecular content for the presence of insoluble polymer

When insoluble polymer is present in a sample, it results in mass loss during the GPC analysis. The insoluble polymer is irreversibly retained on the column or sample filter while the soluble portion of the sample passes through the column. In the case where the refractive index increment (dn/dc) of the polymer can be estimated or measured, one can estimate the sample mass lost on the column. In that case, one makes a correction using an external calibration with standard materials of known concentration and dn/dc to calibrate the response of the refractometer. In the example hereafter a poly(methyl methacrylate) (pMMA) standard is used.

In the external calibration for analysis of acrylic polymers, a pMMA standard of known concentration in tetrahydrofuran, is analysed by GPC and the resulting data are used to find the refractometer constant according to the equation:

K = R/(C × V × dn/dc)

where:

K

=

the refractometer constant (in microvolt second/ml),

R

=

the response of the pMMA standard (in microvolt/second),

C

=

the concentration of the pMMA standard (in mg/ml),

V

=

the injection volume (in ml), and

dn/dc

=

the refractive index increment for pMMA in tetrahydrofuran (in ml/mg).

The following data are typical for a pMMA standard:

R

=

2 937 891

C

=

1,07 mg/ml

V

=

0,1 ml

dn/dc

=

9 × 10-5 ml/mg

The resulting K value, 3,05 × 1011 is then used to calculate the theoretical detector response if 100 % of the polymer injected had eluted through the detector.

A.20.   SOLUTION/EXTRACTION BEHAVIOUR OF POLYMERS IN WATER

1.   METHOD

The method described is a replicate of the revised version of OECD TG 120 (1997). Further technical information is given in reference (1).

1.1.   INTRODUCTION

For certain polymers, such as emulsion polymers, initial preparatory work may be necessary before the method set out hereafter can be used. The method is not applicable to liquid polymers and to polymers that react with water under the test conditions.

When the method is not practical or not possible, the solution/extraction behaviour may be investigated by means of other methods. In such cases, full details and justification should be given for the method used.

1.2.   REFERENCE SUBSTANCES

None.

1.3.   PRINCIPLE OF THE TEST METHOD

The solution/extraction behaviour of polymers in an aqueous medium is determined using the flask method (see A.6 Water Solubility, Flask method) with the modifications described below.

1.4.   QUALITY CRITERIA

None.

1.5.   DESCRIPTION OF THE TEST METHOD

1.5.1.   Equipment

The following equipment is required for the method:

 crushing device, e.g. grinder for the production of particles of known size,

 apparatus for shaking with possibility of temperature control,

 membrane filter system,

 appropriate analytical equipment,

 standardised sieves.

1.5.2.   Sample preparation

A representative sample has first to be reduced to a particle size between 0,125 and 0,25 mm using appropriate sieves. Cooling may be required for the stability of the sample or for the grinding process. Materials of a rubbery nature can be crushed at liquid nitrogen temperature (1).

If the required particle size fraction is not attainable, action should be taken to reduce the particle size as much as possible, and the result reported. In the report, it is necessary to indicate the way in which the crushed sample was stored prior to the test

1.5.3.   Procedure

Three samples of 10 g of the test substance are weighed into each of three vessels fitted with glass stoppers and 1 000 ml of water is added to each vessel. If handling an amount of 10 g polymer proves impracticable, the next highest amount which can be handled should be used and the volume of water adjusted accordingly.

The vessels are tightly stoppered and then agitated at 20 oC. A shaking or stirring device capable of operating at constant temperature should be used. After a period of 24 hours, the content of each vessel is centrifuged or filtered and the concentration of polymer in the clear aqueous phase is determined by a suitable analytical method. If suitable analytical methods for the aqueous phase are not available, the total solubility/extractivity can be estimated from the dry weight of the filter residue or centrifuged precipitate.

It is usually necessary to differentiate quantitatively between the impurities and additives on the one hand and the low molecular weight species on the other hand. In the case of gravimetric determination, it is also important to perform a blank run using no test substance in order to account for residues arising from the experimental procedure.

The solution/extraction behaviour of polymers in water at 37 oC at pH 2 and pH 9 may be determined in the same way as described for the conduct of the experiment at 20 oC. The pH values can be achieved by the addition of either suitable buffers or appropriate acids or bases such as hydrochloric acid, acetic acid, analytical grade sodium or potassium hydroxide or NH3.

Depending on the method of analysis used, one or two tests should be performed. When sufficiently specific methods are available for direct analysis of the aqueous phase for the polymer component, one test as described above should suffice. However, when such methods are not available and determination of the solution/extraction behaviour of the polymer is limited to indirect analysis by determining only the total organic carbon content (TOC) of the aqueous extract, an additional test should be conducted. This additional test should also be done in triplicate, using ten times smaller polymer samples and the same amounts of water as those used in the first test.

1.5.4.   Analysis

1.5.4.1.   Test conducted with one sample size

Methods may be available for direct analysis of polymer components in the aqueous phase. Alternatively, indirect analysis of dissolved/extracted polymer components, by determining the total content of soluble parts and correcting for non polymer-specific components, could also be considered.

Analysis of the aqueous phase for the total polymeric species is possible:

either by a sufficiently sensitive method, e.g.:

 TOC using persulphate or dichromate digestion to yield CO2 followed by estimation by IR or chemical analysis,

 Atomic Absorption Spectrometry (AAS) or its Inductively Coupled Plasma (ICP) emission equivalent for silicon or metal containing polymers,

 UV absorption or spectrofluorimetry for aryl polymers,

 LC-MS for low molecular weight samples,

or by vacuum evaporation to dryness of the aqueous extract and spectroscopic (IR, UV, etc.) or AAS/ICP analysis of the residue.

If analysis of the aqueous phase as such is not practicable, the aqueous extract should be extracted with a water-immiscible organic solvent e.g. a chlorinated hydrocarbon. The solvent is then evaporated and the residue analysed as above for the notified polymer content. Any components in this residue which are identified as being impurities or additives are to be subtracted for the purpose of determining the degree of solution/extraction of the polymer itself.

When relatively large quantities of such materials are present, it may be necessary to subject the residue to e.g. HPLC or GC analysis to differentiate the impurities from the monomer and monomer-derived species present so that the true content of the latter can be determined.

In some cases, simple evaporation of the organic solvent to dryness and weighing the dry residue may be sufficient.

1.5.4.2.   Test conducted with two different sample sizes

All aqueous extracts are analysed for TOC.

A gravimetric determination is performed on the undissolved/not extracted part of the sample. If, after centrifugation or filtering of the content of each vessel, polymer residues remain attached to the wall of the vessel, the vessel should be rinsed with the filtrate until the vessel is cleared from all visible residues. Following which, the filtrate is again centrifuged or filtered. The residues remaining on the filter or in the centrifuge tube are dried at 40 oC under vacuum and weighed. Drying is continued until a constant weight is reached.

2.   DATA

2.1.   TEST CONDUCTED WITH ONE SAMPLE SIZE

The individual results for each of the three flasks and the average values should be given and expressed in units of mass per volume of the solution (typically mg/l) or mass per mass of polymer sample (typically mg/g). Additionally, the weight loss of the sample (calculated as the weight of the solute divided by the weight of the initial sample) should also be given. The relative standard deviations (RSD) should be calculated. Individual figures should be given for the total substance (polymer + essential additives, etc.) and for the polymer only (i.e. after subtracting the contribution from such additives).

2.2.   TEST CONDUCTED WITH TWO DIFFERENT SAMPLE SIZES

The individual TOC values of the aqueous extracts of the two triplicate experiments and the average value for each experiment should be given expressed as units of mass per volume of solution (typically mgC/l), as well as in units of mass per weight of the initial sample (typically mgC/g).

If there is no difference between the results at the high and the low sample/water ratios, this may indicate that all extractable components were indeed extracted. In such a case, direct analysis would normally not be necessary.

The individual weights of the residues should be given and expressed in percentage of the initial weights of the samples. Averages should be calculated per experiment. The differences between 100 and the percentages found represent the percentages of soluble and extractable material in the original sample.

3.   REPORTING

3.1.   TEST REPORT

The test report must include the following information:

3.1.1.   Test substance:

 available information about test substance (identity, additives, impurities, content of low molecular weight species).

3.1.2.   Experimental conditions:

 description of the procedures used and experimental conditions,

 description of the analytical and detection methods.

3.1.3.   Results:

 results of solubility/extractivity in mg/l; individual and mean values for the extraction tests in the various solutions, broken down in polymer content and impurities, additives, etc.,

 results of solubility/extractivity in mg/g of polymer,

 TOC values of aqueous extracts, weight of the solute and calculated percentages, if measured,

 the pH of each sample,

 information about the blank values,

 where necessary, references to the chemical instability of the test substance, during both the testing process and the analytical process,

 all information which is important for the interpretation of the results.

4.   REFERENCES

(1) DIN 53733 (1976) Zerkleinerung von Kunststofferzeugnissen für Prüfzwecke.

A.21.   OXIDISING PROPERTIES (LIQUIDS)

1.   METHOD

1.1.   INTRODUCTION

This test method is designed to measure the potential for a liquid substance to increase the burning rate or burning intensity of a combustible substance, or to form a mixture with a combustible substance which spontaneously ignites, when the two are thoroughly mixed. It is based on the UN test for oxidising liquids (1) and is equivalent to it. However, as this method A.21 is primarily designed to satisfy the requirements of Regulation (EC) No 1907/2006, comparison with only one reference substance is required. Testing and comparison to additional reference substances may be necessary when the results of the test are expected to be used for other purposes. ( 3 )

This test need not be performed when examination of the structural formula establishes beyond reasonable doubt that the substance is incapable of reacting exothermically with a combustible material.

It is useful to have preliminary information on any potential explosive properties of the substance before performing this test.

This test is not applicable to solids, gases, explosive or highly flammable substances, or organic peroxides.

This test may not need to be performed when results for the test substance in the UN test for oxidising liquids (1) are already available.

1.2.   DEFINITIONS AND UNITS

Mean pressure rise time is the mean of the measured times for a mixture under test to produce a pressure rise from 690 kPa to 2 070 kPa above atmospheric.

1.3.   REFERENCE SUBSTANCE

65 % (w/w) aqueous nitric acid (analytical grade) is required as a reference substance. ( 4 )

Optionally, if the experimenter foresees that the results of this test may eventually be used for other purposes (4) , testing of additional reference substances may also be appropriate. ( 5 )

1.4.   PRINCIPLE OF THE TEST METHOD

The liquid to be tested is mixed in a 1 to 1 ratio, by mass, with fibrous cellulose and introduced into a pressure vessel. If during mixing or filling spontaneous ignition occurs, no further testing is necessary.

If spontaneous ignition does not occur the full test is carried out. The mixture is heated in a pressure vessel and the mean time taken for the pressure to rise from 690 kPa to 2 070 kPa above atmospheric is determined. This is compared with the mean pressure rise time for the 1:1 mixture of the reference substance(s) and cellulose.

1.5.   QUALITY CRITERIA

In a series of five trials on a single substance no results should differ by more than 30 % from the arithmetic mean. Results that differ by more than 30 % from the mean should be discarded, the mixing and filling procedure improved and the testing repeated.

1.6.   DESCRIPTION OF THE METHOD

1.6.1.   Preparation

1.6.1.1.   Combustible substance

Dried, fibrous cellulose with a fibre length between 50 and 250 μm and a mean diameter of 25 μm ( 6 ), is used as the combustible material. It is dried to constant weight in a layer not more than 25 mm thick at 105 oC for four hours and kept in a desiccator, with desiccant, until cool and required for use. The water content of the dried cellulose should be less than 0,5 % by dry mass ( 7 ). If necessary, the drying time should be prolonged to achieve this. ( 8 ) The same batch of cellulose is to be used throughout the test.

1.6.1.2.   Apparatus

1.6.1.2.1.    Pressure vessel

A pressure vessel is required. The vessel consists of a cylindrical steel pressure vessel 89 mm in length and 60 mm in external diameter (see figure 1). Two flats are machined on opposite sides (reducing the cross-section of the vessel to 50 mm) to facilitate holding whilst fitting up the firing plug and vent plug. The vessel, which has a bore of 20 mm diameter is internally rebated at either end to a depth of 19 mm and threaded to accept 1'' British Standard Pipe (BSP) or metric equivalent. A pressure take-off, in the form of a side arm, is screwed into the curved face of the pressure vessel 35 mm from one end and at 90o to the machined flats. The socket for this is bored to a depth of 12 mm and threaded to accept the 1/2" BSP (or metric equivalent) thread on the end of the side-arm. If necessary, an inert seal is fitted to ensure a gas-tight seal. The side-arm extends 55 mm beyond the pressure vessel body and has a bore of 6 mm. The end of the side-arm is rebated and threaded to accept a diaphragm type pressure transducer. Any pressure-measuring device may be used provided that it is not affected by the hot gases or the decomposition products and is capable of responding to rates of pressure rise of 690-2 070 kPa in not more than 5 ms.

The end of the pressure vessel farthest from the side-arm is closed with a firing plug which is fitted with two electrodes, one insulated from, and the other earthed to, the plug body. The other end of the pressure vessel is closed by a bursting disk (bursting pressure approximately 2 200 kPa) held in place with a retaining plug which has a 20 mm bore. If necessary, an inert seal is used with the firing plug to ensure a gas-tight fit. A support stand (figure 2) holds the assembly in the correct attitude during use. This usually comprises a mild steel base plate measuring 235 mm × 184 mm × 6 mm and a 185 mm length of square hollow section (S.H.S.) 70 mm × 70 mm × 4 mm.

A section is cut from each of two opposite sides at one end of the length of S.H.S. so that a structure having two flat sided legs surmounted by 86 mm length of intact box section results. The ends of these flat sides are cut to an angle of 60o to the horizontal and welded to the base plate. A slot measuring 22 mm wide × 46 mm deep is machined in one side of the upper end of the base section such that when the pressure vessel assembly is lowered, firing plug end first, into the box section support, the side-arm is accommodated in the slot. A piece of steel 30 mm wide and 6 mm thick is welded to the lower internal face of the box section to act as a spacer. Two 7 mm thumb screws, tapped into the opposite face, serve to hold the pressure vessel firmly in place. Two 12 mm wide strips of 6 mm thick steel, welded to the side pieces abutting the base of the box section, support the pressure vessel from beneath.

1.6.1.2.2.    Ignition system

The ignition system consists of a 25 cm long Ni/Cr wire with a diameter 0,6 mm and a resistance of 3,85 ohm/m. The wire is wound, using a 5 mm diameter rod, in the shape of a coil and is attached to the firing plug electrodes. The coil should have one of the configurations shown in figure 3. The distance between the bottom of the vessel and the underside of the ignition coil should be 20 mm. If the electrodes are not adjustable, the ends of the ignition wire between the coil and the bottom of the vessel should be insulated by a ceramic sheath. The wire is heated by a constant current power supply able to deliver at least 10 A.

1.6.2.   Performance of the test ( 9 )

The apparatus, assembled complete with pressure transducer and heating system but without the bursting disk in position, is supported firing plug end down. 2,5 g of the liquid to be tested is mixed with 2,5 g of dried cellulose in a glass beaker using a glass stirring rod ( 10 ). For safety, the mixing should be performed with a safety shield between the operator and mixture. If the mixture ignites during mixing or filling, no further testing is necessary. The mixture is added, in small portions with tapping, to the pressure vessel making sure that the mixture is packed around the ignition coil and is in good contact with it. It is important that the coil is not distorted during the packing process as this may lead to erroneous results ( 11 ). The bursting disk is placed in position and the retaining plug is screwed in tightly. The charged vessel is transferred to the firing support stand, bursting disk uppermost, which should be located in a suitable, armoured fume cupboard or firing cell. The power supply is connected to the external terminals of the firing plug and 10 A applied. The time between the start of mixing and switching on the power should not exceed 10 minutes.

The signal produced by the pressure transducer is recorded on a suitable system which allows both evaluation and the generation of a permanent record of the time pressure profile obtained (e.g. a transient recorder coupled to a chart recorder). The mixture is heated until the bursting disk ruptures or until at least 60 s have elapsed. If the bursting disk does not rupture, the mixture should be allowed to cool before carefully dismantling the apparatus, taking precautions to allow for any pressurisation which may occur. Five trials are performed with the test substance and the reference substance(s). The time taken for the pressure to rise from 690 kPa to 2 070 kPa above atmospheric is noted. The mean pressure rise time is calculated.

In some cases, substances may generate a pressure rise (too high or too low), caused by chemical reactions not characterising the oxidising properties of the substance. In these cases, it may be necessary to repeat the test with an inert substance, e.g. diatomite (kieselguhr), in place of the cellulose in order to clarify the nature of the reaction.

2.   DATA

Pressure rise times for both the test substance and the reference substance(s). Pressure rise times for the tests with an inert substance, if performed.

2.1.   TREATMENT OF RESULTS

The mean pressure rise times for both the test substance and the reference substances(s) are calculated.

The mean pressure rise time for the tests with an inert substance (if performed) is calculated.

Some examples of results are shown in Table 1.



Table 1

Examples of results ()

Substance ()

Mean pressure rise time for a 1:1 mixture with celulose

(ms)

Ammonium dichromate, saturated aqueous solution

20 800

Calcium nitrate, saturated aqueous solution

6 700

Ferric nitrate, saturated aqueous solution

4 133

Lithium perchlorate, saturated aqueous solution

1 686

Magnesium perchlorate, saturated aqueous solution

777

Nickel nitrate, saturated aqueous solution

6 250

Nitric acid, 65 %

4 767 ()

Perchloric acid, 50 %

121 ()

Perchloric acid, 55 %

59

Potassium nitrate, 30 % aqueous solution

26 690

Silver nitrate, saturated aqueous solution

 ()

Sodium chlorate, 40 % aqueous solution

2 555 ()

Sodium nitrate, 45 % aqueous solution

4 133

Inert substance

 

Water: cellulose

 ()

(1)   See reference (1) for classification under the UN transport scheme.

(2)   Saturated solutions should be prepared at 20 oC.

(3)   Mean value from interlaboratory comparative trials.

(4)   Maximum pressure of 2 070 kPa not reached.

3.   REPORT

3.1.   TEST REPORT

The test report should include the following information:

 the identity, composition, purity, etc. of the substance tested,

 the concentration of the test substance,

 the drying procedure of the cellulose used,

 the water content of the cellulose used,

 the results of the measurements,

 the results from tests with an inert substance, if any,

 the calculated mean pressure rise times,

 any deviations from this method and the reasons for them,

 all additional information or remarks relevant to the interpretation of the results.

3.2.   INTERPRETATION OF THE RESULTS ( 12 )

The test results are assessed on the basis of:

(a) whether the mixture of test substance and cellulose spontaneously ignites; and

(b) the comparison of the mean time taken for the pressure to rise from 690 kPa to 2 070 kPa with that of the reference substance(s).

A liquid substance is to be considered as an oxidiser when:

(a) a 1:1 mixture, by mass, of the substance and cellulose spontaneously ignites; or

(b) a 1:1 mixture, by mass, of the substance and cellulose exhibits a mean pressure rise time less than or equal to the mean pressure rise time of a 1:1 mixture, by mass, of 65 % (w/w) aqueous nitric acid and cellulose.

In order to avoid a false positive result, if necessary, the results obtained when testing the substance with an inert material should also be considered when interpreting the results.

4.   REFERENCES

(1) Recommendations on the Transport of Dangerous Goods, Manual of Tests and Criteria. 3rd revised edition. UN Publication No: ST/SG/AC.10/11/Rev. 3, 1999, page 342. Test O.2: Test for oxidising liquids.

Figure 1

Pressure vessel

(A) Pressure vessel body(B) Bursting disk retaining plug(C) Firing plug(D) Soft lead washer(E) Bursting disc(F) Side arm(G) Pressure transducer head(H) Washer(J) Insulated electrode(K) Earthed electrode(L) Insulation(M) Steel cone(N) Washer distorting groove

Figure 2

Support stand

image

Figure 3

Ignition system

(A) Ignition coil(B) Insulation(C) Electrodes(D) Firing plug

Note: either of these configurations may be used.

▼M1

A.22.   LENGTH WEIGHTED GEOMETRIC MEAN DIAMETER OF FIBRES

1.   METHOD

1.1.   INTRODUCTION

This method describes a procedure to measure the Length Weighted Geometric Mean Diameter (LWGMD) of bulk Man Made Mineral Fibres (MMMF). As the LWGMD of the population will have a 95 % probability of being between the 95 % confidence levels (LWGMD ± two standard errors) of the sample, the value reported (the test value) will be the lower 95 % confidence limit of the sample (i.e. LWGMD — 2 standard errors). The method is based on an update (June 1994) of a draft HSE industry procedure agreed at a meeting between ECFIA and HSE at Chester on 26/9/93 and developed for and from a second inter-laboratory trial (1, 2). This measurement method can be used to characterise the fibre diameter of bulk substances or products containing MMMFs including refractory ceramic fibres (RCF), man-made vitreous fibres (MMVF), crystalline and polycrystalline fibres.

Length weighting is a means of compensating for the effect on the diameter distribution caused by the breakage of long fibres when sampling or handling the material. Geometric statistics (geometric mean) are used to measure the size distribution of MMMF diameters because these diameters usually have size distributions that approximate to log normal.

Measuring length as well as diameter is both tedious and time consuming but, if only those fibres that touch an infinitely thin line on a SEM field of view are measured, then the probability of selecting a given fibre is proportional to its length. As this takes care of the length in the length weighting calculations, the only measurement required is the diameter and the LWGMD-2SE can be calculated as described.

1.2.   DEFINITIONS

Particle: An object with a length to width ratio of less than 3:1.

Fibre: An object with a length to with ratio (aspect ratio) of at least 3:1.

1.3.   SCOPE AND LIMITATIONS

The method is designed to look at diameter distributions which have median diameters from 0,5 μm to 6 μm. Larger diameters can be measured by using lower SEM magnifications but the method will be increasingly limited for finer fibre distributions and a TEM (transmission electron microscope) measurement is recommended if the median diameter is below 0,5 μm.

1.4.   PRINCIPLE OF THE TEST METHOD

A number of representative core samples are taken from the fibre blanket or from loose bulk fibre. The bulk fibres are reduced in length using a crushing procedure and a representative sub-sample dispersed in water. Aliquots are extracted and filtered through a 0,2 μm pore size, polycarbonate filter and prepared for examination using scanning electron microscope (SEM) techniques. The fibre diameters are measured at a screen magnification of × 10 000 or greater ( 13 ) using a line intercept method to give an unbiased estimate of the median diameter. The lower 95 % confidence interval (based on a one sided test) is calculated to give an estimate of the lowest value of the geometric mean fibre diameter of the material.

1.5.   DESCRIPTION OF THE TEST METHOD

1.5.1.   Safety/precautions

Personal exposure to airborne fibres should be minimised and a fume cupboard or glove box should be used for handling the dry fibres. Periodic personal exposure monitoring should be carried out to determine the effectiveness of the control methods. When handling MMMF’s disposable gloves should be worn to reduce skin irritation and to prevent cross-contamination.

1.5.2.   Apparatus/equipment

 Press and dyes (capable of producing 10 MPa).

 0,2 μm pore size polycarbonate capillary pore filters (25 mm diameter).

 5 μm pore size cellulose ester membrane filter for use as a backing filter.

 Glass filtration apparatus (or disposable filtration systems) to take 25 mm diameter filters (e.g. Millipore glass microanalysis kit, type No XX10 025 00).

 Freshly distilled water that has been filtered through a 0,2 μm pore size filter to remove micro-organisms.

 Sputter coater with a gold or gold/palladium target.

 Scanning electron microscope capable of resolving down to 10 nm and operating at × 10 000 magnification.

 Miscellaneous: spatulas, type 24 scalpel blade, tweezers, SEM tubes, carbon glue or carbon adhesive tape, silver dag.

 Ultrasonic probe or bench top ultrasonic bath.

 Core sampler or cork borer, for taking core samples from MMMF blanket.

1.5.3.   Test Procedure

1.5.3.1.   Sampling

For blankets and bats a 25 mm core sampler or cork borer is used to take samples of the cross-section. These should be equally spaced across the width of a small length of the blanket or taken from random areas if long lengths of the blanket are available. The same equipment can be used to extract random samples from loose fibre. Six samples should be taken when possible, to reflect spatial variations in the bulk material.

The six core samples should be crushed in a 50 mm diameter dye at 10 MPa. The material is mixed with spatula and re-pressed at 10 MPa. The material is then removed from the dye and stored in a sealed glass bottle.

1.5.3.2.   Sample Preparation

If necessary, organic binder can be removed by placing the fibre inside a furnace at 450 °C for about one hour.

Cone and quarter to subdivide the sample (this should be done inside a dust cupboard).

Using a spatula, add a small amount (< 0,5 g) of sample to 100 ml of freshly distilled water that has been filtered through a 0,2 μm membrane filter (alternative sources of ultra pure water may be used if they are shown to be satisfactory). Disperse thoroughly by the use of an ultrasonic probe operated at 100 W power and tuned so that cavitation occurs. (If a probe is not available use the following method: repeatedly shake and invert for 30 seconds; ultrasonic in a bench top ultrasonic bath for five minutes; then repeatedly shake and invert for a further 30 seconds.)

Immediately after dispersion of the fibre, remove a number of aliquots (e.g. three aliquots of 3, 6 and 10 ml) using a wide-mouthed pipette (2-5 ml capacity).

Vacuum filter each aliquot through a 0,2 μm polycarbonate filter supported by a 5 μm pore MEC backing filter, using a 25 mm glass filter funnel with a cylindrical reservoir. Approximately 5 ml of filtered distilled water should be placed into the funnel and the aliquot slowly pipetted into the water holding the pipette tip below the meniscus. The pipette and the reservoir must be flushed thoroughly after pipetting, as thin fibres have a tendency to be located more on the surface.

Carefully remove the filter and separate it from the backing filter before placing it in a container to dry.

Cut a quarter or half filter section of the filtered deposit with a type 24 scalpel blade using a rocking action. Carefully attach the cut section to a SEM stub using a sticky carbon tab or carbon glue. Silver dag should be applied in at least three positions to improve the electrical contact at the edges of the filter and the stub. When the glue/silver dag is dry, sputter coat approximately 50 nm of gold or gold/palladium onto the surface of the deposit.

1.5.3.3.   SEM calibration and operation

1.5.3.3.1.   Calibration

The SEM calibration should be checked at least once a week (ideally once a day) using a certified calibration grid. The calibration should be checked against a certified standard and if the measured value (SEM) is not within ± 2 % of the certified value, then the SEM calibration must be adjusted and re-checked.

The SEM should be capable of resolving at least a minimum visible diameter of 0,2 μm, using a real sample matrix, at a magnification of × 2 000.

1.5.3.3.2.   Operation

The SEM should be operated at 10 000 magnification ( 14 ) using conditions that give good resolution with an acceptable image at slow scan rates of, for example, 5 seconds per frame. Although the operational requirements of different SEMs may vary, generally to obtain the best visibility and resolution, with relatively low atomic weight materials, accelerating voltages of 5-10 keV should be used with a small spot size setting and short working distance. As a linear traverse is being conducted, then a 0° tilt should be used to minimise re-focussing or, if the SEM has a eucentric stage, the eucentric working distance should be used. Lower magnification may be used if the material does not contain small (diameter) fibres and the fibre diameters are large (> 5 μm).

1.5.3.4.   Sizing

1.5.3.4.1.   Low magnification examination to assess the sample

Initially the sample should be examined at low magnification to look for evidence of clumping of large fibres and to assess the fibre density. In the event of excessive clumping it is recommended that a new sample is prepared.

For statistical accuracy it is necessary to measure a minimum number of fibres and high fibre density may seem desirable as examining empty fields is time consuming and does not contribute to the analysis. However, if the filter is overloaded, it becomes difficult to measure all the measurable fibres and, because small fibres may be obscured by larger ones, they may be missed.

Bias towards over estimating the LWGMD may result from fibre densities in excess of 150 fibres per millimetre of linear traverse. On the other hand, low fibre concentrations will increase the time of analysis and it is often cost effective to prepare a sample with a fibre density closer to the optimum than to persist with counts on low concentration filters. The optimum fibre density should give an average of about one or two countable fibre per fields of view at 5 000 magnification. Nevertheless the optimum density will depend on the size (diameter) of the fibres, so it is necessary that the operator uses some expert judgement in order to decide whether the fibre density is close to optimal or not.

1.5.3.4.2.   Length weighting of the fibre diameters

Only those fibres that touch (or cross) an (infinitely) thin line drawn on the screen of the SEM are counted. For this reason a horizontal (or vertical) line is drawn across the centre of the screen.

Alternatively a single point is placed at the centre of the screen and a continuous scan in one direction across the filter is initiated. Each fibre of aspect ratio grater than 3:1 touching or crossing this point has its diameter measured and recorded.

1.5.3.4.3.   Fibre sizing

It is recommended that a minimum of 300 fibres are measured. Each fibre is measured only once at the point of intersection with the line or point drawn on the image (or close to the point of intersection if the fibre edges are obscured). If fibres with non-uniform cross sections are encountered, a measurement representing the average diameter of the fibre should be used. Care should be taken in defining the edge and measuring the shortest distance between the fibre edges. Sizing may be done on line, or off-line on stored images or photographs. Semi-automated image measurement systems that download data directly into a spreadsheet are recommended, as they save time, eliminate transcription errors and calculations can be automated.

The ends of long fibres should be checked at low magnification to ensure that they do not curl back into the measurement field of view and are only measured once.

2.   DATA

2.1.   TREATMENT OF RESULTS

Fibre diameters do not usually have a normal distribution. However, by performing a log transformation it is possible to obtain a distribution that approximates to normal.

Calculate the arithmetic mean (mean lnD) and the standard deviation (SDlnD) of the log to base e values (lnD) of the n fibre diameters (D).



image

(1)

image

(2)

The standard deviation is divided by the square root of the number of measurements (n) to obtain the standard error (SElnD).



image

(3)

Subtract two times the standard error from the mean and calculate the exponential of this value (mean minus two standard errors) to give the geometric mean minus two geometric standard errors.



image

(4)

3.   REPORTING

TEST REPORT

The test report should include at least the following information:

 The value of LWGMD-2SE.

 Any deviations and particularly those which may have an effect on the precision or accuracy of the results with appropriate justifications.

4.   REFERENCES

1. B. Tylee SOP MF 240. Health and Safety Executive, February 1999.

2. G. Burdett and G. Revell. Development of a standard method to measure the length-weigthed geometric mean fibre diameter: Results of the Second inter-laboratory exchange. IR/L/MF/94/07. Project R42.75 HPD. Health and Safety Executive, Research and Laboratory Services Division, 1994.

▼B




PART B: METHODS FOR THE DETERMINATION OF TOXICITY AND OTHER HEALTH EFFECTS

TABLE OF CONTENTS

GENERAL INTRODUCTION

B.1 bis.

ACUTE ORAL TOXICITY — FIXED DOSE PROCEDURE

B.1 tris.

ACUTE ORAL TOXICITY — ACUTE TOXIC CLASS METHOD

B.2.

ACUTE TOXICITY (INHALATION)

B.3.

ACUTE TOXICITY (DERMAL)

B.4.

ACUTE TOXICITY: DERMAL IRRITATION/CORROSION

B.5.

ACUTE TOXICITY: EYE IRRITATION/CORROSION

B.6.

SKIN SENSITISATION

B.7.

REPEATED DOSE (28 DAYS) TOXICITY (ORAL)

B.8.

REPEATED DOSE (28 DAYS) TOXICITY (INHALATION)

B.9.

REPEATED DOSE (28 DAYS) TOXICITY (DERMAL)

B.10.

MUTAGENICITY — IN VITRO MAMMALIAN CHROMOSOME ABERRATION TEST

B.11.

MUTAGENICITY — IN VIVO MAMMALIAN BONE MARROW CHROMOSOME ABERRATION TEST

B.12.

MUTAGENICITY — IN VIVO MAMMALIAN ERYTHROCYTE MICRONUCLEUS TEST

B.13/14.

MUTAGENICITY: REVERSE MUTATION TEST USING BACTERIA

B.15.

MUTAGENICITY TESTING AND SCREENING FOR CARCINOGENICITY GENE MUTATION — SACCHAROMYCES CEREVISIAE

B.16.

MITOTIC RECOMBINATION — SACCHAROMYCES CEREVISIAE

B.17.

MUTAGENICITY — IN VITRO MAMMALIAN CELL GENE MUTATION TEST

B.18.

DNA DAMAGE AND REPAIR — UNSCHEDULED DNA SYNTHESIS — MAMMALIAN CELLS IN VITRO

B.19.

SISTER CHROMATID EXCHANGE ASSAY IN VITRO

B.20.

SEX-LINKED RECESSIVE LETHAL TEST IN DROSOPHILA MELANOGASTER

B.21.

IN VITRO MAMMALIAN CELL TRANSFORMATION TESTS

B.22.

RODENT DOMINANT LETHAL TEST

B.23.

MAMMALIAN SPERMATOGONIAL CHROMOSOME ABERRATION TEST

B.24.

MOUSE SPOT TEST

B.25.

MOUSE HERITABLE TRANSLOCATION

B.26.

SUB-CHRONIC ORAL TOXICITY TEST REPEATED DOSE 90 — DAY ORAL TOXICITY STUDY IN RODENTS

B.27.

SUB-CHRONIC ORAL TOXICITY TEST REPEATED DOSE 90 — DAY ORAL TOXICITY STUDY IN NON-RODENTS

B.28.

SUB-CHRONIC DERMAL TOXICITY STUDY 90-DAY REPEATED DERMAL DOSE STUDY USING RODENT SPECIES

B.29.

SUB-CHRONIC INHALATION TOXICITY STUDY 90-DAY REPEATED INHALATION DOSE STUDY USING RODENT SPECIES

B.30.

CHRONIC TOXICITY TEST

B.31.

PRENATAL DEVELOPMENTAL TOXICITY STUDY

B.32.

CARCINOGENICITY TEST

B.33.

COMBINED CHRONIC TOXICITY/CARCINOGENICITY TEST

B.34.

ONE-GENERATION REPRODUCTION TOXICITY TEST

B.35.

TWO-GENERATION REPRODUCTION TOXICITY STUDY

B.36.

TOXICOKINETICS

B.37.

DELAYED NEUROTOXICITY OF ORGANOPHOSPHORUS SUBSTANCES FOLLOWING ACUTE EXPOSURE

B.38.

DELAYED NEUROTOXICITY OF ORGANOPHOSPHORUS SUBSTANCES 28 DAY REPEATED DOSE STUDY

B.39.

UNSCHEDULED DNA SYNTHESIS (UDS) TEST WITH MAMMALIAN LIVER CELLS IN VIVO

B.40.

IN VITRO SKIN CORROSION: TRANSCUTANEOUS ELECTRICAL RESISTANCE TEST (TER)

B.40 BIS.

IN VITRO SKIN CORROSION: HUMAN SKIN MODEL TEST

B.41.

IN VITRO 3T3 NRU PHOTOTOXICITY TEST

B.42.

SKIN SENSITISATION: LOCAL LYMPH NODE ASSAY

B.43.

NEUROTOXICITY STUDY IN RODENTS

B.44.

SKIN ABSORPTION: IN VIVO METHOD

B.45.

SKIN ABSORPTION: IN VITRO METHOD

B.46.

IN VITRO SKIN IRRITATION: RECONSTRUCTED HUMAN EPIDERMIS TEST METHOD

B.47.

BOVINE CORNEAL OPACITY AND PERMEABILITY TEST METHOD FOR IDENTIFYING OCULAR CORROSIVES AND SEVERE IRRITANTS

B.48.

ISOLATED CHICKEN EYE TEST METHOD FOR IDENTIFYING OCULAR CORROSIVES AND SEVERE IRRITANTS

B.49.

IN VITRO MAMMALIAN CELL MICRONUCLEUS TEST

B.50.

SKIN SENSITISATION: LOCAL LYMPH NODE ASSAY: DA

B.51.

SKIN SENSITISATION: LOCAL LYMPH NODE ASSAY: BrdU-ELISA

GENERAL INTRODUCTION

A.   CHARACTERISATION OF THE TEST SUBSTANCE

The composition of the test substance, including major impurities, and its relevant physico-chemical properties including stability, should be known prior to the initiation of any toxicity study.

The physico-chemical properties of the test substance provide important information for the selection of the route of administration, the design of each particular study and the handling and storage of the test substance.

The development of an analytical method for qualitative and quantitative determination of the test substance (including major impurities when possible) in the dosing medium and the biological material should precede the initiation of the study.

All information relating to the identification, the physico-chemical properties, the purity, and behaviour of the test substance should be included in the test report.

B.   ANIMAL CARE

Stringent control of environmental conditions and proper animal care techniques are essential in toxicity testing.

(i)   Housing conditions

The environmental conditions in the experimental animal rooms or enclosures should be appropriate to the test species. For rats, mice and guinea pigs, suitable conditions are a room temperature of 22 oC ± 3 oC with a relative humidity of 30 to 70 %; for rabbits the temperature should be 20 ± 3 oC with a relative humidity of 30 to 70 %.

Some experimental techniques are particularly sensitive to temperature effects and, in these cases, details of appropriate conditions are included in the description of the test method. In all investigations of toxic effects, the temperature and humidity should be monitored, recorded, and included in the final report of the study.

Lighting should be artificial, the sequence being 12 hours light, 12 hours dark. Details of the lighting pattern should be recorded and included in the final report of the study.

Unless otherwise specified in the method, animals may be housed individually, or be caged in small groups of the same sex; for group caging, no more than five animals should be housed per cage.

In reports of animal experiments, it is important to indicate the type of caging used and the number of animals housed in each cage both during exposure to the chemical and any subsequent observation period.

(ii)   Feeding conditions

Diets should meet all the nutritional requirements of the species under test. Where test substances are administered to animals in their diet the nutritional value may be reduced by interaction between the substance and a dietary constituent. The possibility of such a reaction should be considered when interpreting the results of tests. Conventional laboratory diets may be used with an unlimited supply of drinking water. The choice of the diet may be influenced by the need to ensure a suitable admixture of a test substance when administered by this method.

Dietary contaminants which are known to influence the toxicity should not be present in interfering concentrations.

C.   ALTERNATIVE TESTING

The European Union is committed to promoting the development and validation of alternative techniques which can provide the same level of information as current animal tests, but which use fewer animals, cause less suffering or avoid the use of animals completely.

Such methods, as they become available, must be considered wherever possible for hazard characterisation and consequent classification and labelling for intrinsic hazards and chemical safety assessment.

D.   EVALUATION AND INTERPRETATION

When tests are evaluated and interpreted, limitations in the extent to which the results of animal and in vitro studies can be extrapolated directly to man must be considered and therefore, evidence of adverse effects in humans, where available, may be used for confirmation of testing results.

E.   LITERATURE REFERENCES

Most of these methods are developed within the framework of the OECD programme for Testing Guidelines, and should be performed in conformity with the principles of Good Laboratory Practice, in order to ensure as wide as possible ‘mutual acceptance of data’.

Additional information may be found in the references listed in the OECD guidelines and the relevant literature published elsewhere.

B.1 bis.   ACUTE ORAL TOXICITY — FIXED DOSE PROCEDURE

1.   METHOD

This test method is equivalent to OECD TG 420 (2001)

1.1.   INTRODUCTION

Traditional methods for assessing acute toxicity use death of animals as an endpoint. In 1984, a new approach to acute toxicity testing was suggested by the British Toxicology Society based on the administration at a series of fixed dose levels (1). The approach avoided using death of animals as an endpoint, and relied instead on the observation of clear signs of toxicity at one of a series of fixed dose levels. Following UK (2) and international (3) in vivo validation studies the procedure was adopted as a testing method in 1992. Subsequently, the statistical properties of the Fixed Dose Procedure have been evaluated using mathematical models in a series of studies (4)(5)(6). Together, the in vivo and modelling studies have demonstrated that the procedure is reproducible, uses fewer animals and causes less suffering than the traditional methods and is able to rank substances in a similar manner to the other acute toxicity testing methods.

Guidance on the selection of the most appropriate test method for a given purpose can be found in the Guidance Document on Acute Oral Toxicity Testing (7). This guidance document also contains additional information on the conduct and interpretation of Testing Method B.1bis.

It is a principle of the method that in the main study only moderately toxic doses are used, and that administration of doses that are expected to be lethal should be avoided. Also, doses that are known to cause marked pain and distress, due to corrosive or severely irritant actions, need not be administered. Moribund animals, or animals obviously in pain or showing signs of severe and enduring distress shall be humanely killed, and are considered in the interpretation of the test results in the same way as animals that died on test. Criteria for making the decision to kill moribund or severely suffering animals, and guidance on the recognition of predictable or impending death, are the subject of a separate Guidance Document (8).

The method provides information on the hazardous properties and allows the substance to be ranked and classified according to the Globally Harmonised System (GHS) for the classification of chemicals which cause acute toxicity (9).

The testing laboratory should consider all available information on the test substance prior to conducting the study. Such information will include the identity and chemical structure of the substance; its physico-chemical properties; the results of any other in vitro or in vivo toxicity tests on the substance; toxicological data on structurally related substances; and the anticipated use(s) of the substance. This information is necessary to satisfy all concerned that the test is relevant for the protection of human health, and will help in the selection of an appropriate starting dose.

1.2.   DEFINITIONS

Acute oral toxicity: refers to those adverse effects occurring following oral administration of a single dose of a substance or multiple doses given within 24 hours.

Delayed death: means that an animal does not die or appear moribund within 48 hours but dies later during the 14-day observation period.

Dose: is the amount of test substance administered. Dose is expressed as weight of test substance per unit weight of test animal (e.g. mg/kg).

Evident toxicity: is a general term describing clear signs of toxicity following the administration of test substance (see (3) for examples) such that at the next highest fixed dose either severe pain and enduring signs of severe distress, moribund status (criteria are presented in the Humane Endpoints Guidance Document (8)), or probable mortality in most animals can be expected.

GHS: Globally Harmonised Classification System for Chemical Substances and Mixtures. A joint activity of OECD (human health and the environment), UN Committee of Experts on Transport of Dangerous Goods (physical-chemical properties) and ILO (hazard communication) and coordinated by the Interorganisation Programme for the Sound Management of Chemicals (IOMC).

Impending death: when moribund state or death is expected prior to the next planned time of observation. Signs indicative of this state in rodents could include convulsions, lateral position, recumbence and tremor. (See the Humane Endpoint Guidance Document (8) for more details).

LD 50 (median lethal dose): is a statistically derived single dose of a substance that can be expected to cause death in 50 % of animals when administered by the oral route. The LD 50 value is expressed in terms of weight of test substance per unit weight of test animal (mg/kg).

Limit dose: refers to a dose at an upper limitation on testing (2 000 or 5 000 mg/kg).

Moribund status: being in a state of dying or inability to survive, even if treated. (See the Humane Endpoint Guidance Document (8) for more details).

Predictable death: presence of clinical signs indicative of death at a known time in the future before the planned end of the experiment, for example: inability to reach water or food. (See the Humane Endpoint Guidance Document (8) for more details).

1.3.   PRINCIPLE OF THE TEST METHOD

Groups of animals of a single sex are dosed in a stepwise procedure using the fixed doses of 5, 50, 300 and 2 000 mg/kg (exceptionally an additional fixed dose of 5 000 mg/kg may be considered, see Section 1.6.2). The initial dose level is selected on the basis of a sighting study as the dose expected to produce some signs of toxicity without causing severe toxic effects or mortality. Clinical signs and conditions associated with pain, suffering, and impending death, are described in detail in a separate OECD Guidance Document (8). Further groups of animals may be dosed at higher or lower fixed doses, depending on the presence or absence of signs of toxicity or mortality. This procedure continues until the dose causing evident toxicity or no more than one death is identified, or when no effects are seen at the highest dose or when deaths occur at the lowest dose.

1.4.   DESCRIPTION OF THE TEST METHOD

1.4.1.   Selection of animal species

The preferred rodent species is the rat, although other rodent species may be used. Normally females are used (7). This is because literature surveys of conventional LD50 tests show that usually there is little difference in sensitivity between the sexes, but in those cases where differences are observed, females are generally slightly more sensitive (10). However, if knowledge of the toxicological or toxicokinetic properties of structurally related chemicals indicates that males are likely to be more sensitive then this sex should be used. When the test is conducted in males, adequate justification should be provided.

Healthy young adult animals of commonly used laboratory strains should be employed. Females should be nulliparous and non-pregnant. Each animal, at the commencement of its dosing, should be between eight and 12 weeks old and its weight should fall in an interval within ± 20 % of the mean weight of any previously dosed animals.

1.4.2.   Housing and feeding conditions

The temperature of the experimental animal room should be 22 oC (± 3 oC). Although the relative humidity should be at least 30 % and preferably not exceed 70 % other than during room cleaning the aim should be 50-60 %. Lighting should be artificial, the sequence being 12 hours light, 12 hours dark. For feeding, conventional laboratory diets may be used with an unlimited supply of drinking water. Animals may be group-caged by dose, but the number of animals per cage must not interfere with clear observations of each animal.

1.4.3.   Preparation of animals

The animals are randomly selected, marked to permit individual identification, and kept in their cages for at least five days prior to the start of dosing to allow for acclimatisation to the laboratory conditions.

1.4.4.   Preparation of doses

In general test substances should be administered in a constant volume over the range of doses to be tested by varying the concentration of the dosing preparation. Where a liquid end product or mixture is to be tested however, the use of the undiluted test substance, i.e. at a constant concentration, may be more relevant to the subsequent risk assessment of that substance, and is a requirement of some regulatory authorities. In either case, the maximum dose volume for administration must not be exceeded. The maximum volume of liquid that can be administered at one time depends on the size of the test animal. In rodents, the volume should not normally exceed 1ml /100 g of body weight: however in the case of aqueous solutions 2 ml/100 g body weight can be considered. With respect to the formulation of the dosing preparation, the use of an aqueous solution/suspension/emulsion is recommended wherever possible, followed in order of preference by a solution/suspension/emulsion in oil (e.g. corn oil) and then possibly solution in other vehicles. For vehicles other than water the toxicological characteristics of the vehicle should be known. Doses must be prepared shortly prior to administration unless the stability of the preparation over the period during which it will be used is known and shown to be acceptable.

1.5.   PROCEDURE

1.5.1.   Administration of doses

The test substance is administered in a single dose by gavage using a stomach tube or a suitable intubation canula. In the unusual circumstance that a single dose is not possible, the dose may be given in smaller fractions over a period not exceeding 24 hours.

Animals should be fasted prior to dosing (e.g. with the rat, food but not water should be withheld over-night; with the mouse, food but not water should be withheld for three to four hours). Following the period of fasting, the animals should be weighed and the test substance administered. After the substance has been administered, food may be withheld for a further three to four hours in rats or one to two hours in mice. Where a dose is administered in fractions over a period of time, it may be necessary to provide the animals with food and water depending on the length of the period.

1.5.2.   Sighting study

The purpose of the sighting study is to allow selection of the appropriate starting dose for the main study. The test substance is administered to single animals in a sequential manner following the flowcharts in Appendix 1. The sighting study is completed when a decision on the starting dose for the main study can be made (or if a death is seen at the lowest fixed dose).

The starting dose for the sighting study is selected from the fixed dose levels of 5, 50, 300 and 2 000 mg/kg as a dose expected to produce evident toxicity based, when possible, on evidence from in vivo and in vitro data from the same chemical and from structurally related chemicals. In the absence of such information, the starting dose will be 300 mg/kg.

A period of at least 24 hours will be allowed between the dosing of each animal. All animals should be observed for at least 14 days.

Exceptionally, and only when justified by specific regulatory needs, the use of an additional upper fixed dose level of 5 000 mg/kg may be considered (see Appendix 3). For reasons of animal welfare concern, testing of animals in GHS Category 5 ranges (2 000-5 000 mg/kg is discouraged and should only be considered when there is a strong likelihood that the results of such a test have a direct relevance for protecting human or animal health or the environment.

In cases where an animal tested at the lowest fixed dose level (5 mg/kg) in the sighting study dies, the normal procedure is to terminate the study and assign the substance to GHS Category 1 (as shown in Appendix 1). However, if further confirmation of the classification is required, an optional supplementary procedure may be conducted, as follows. A second animal is dosed at 5 mg/kg. If this second animal dies, then GHS Category 1 will be confirmed and the study will be immediately terminated. If the second animal survives, then a maximum of three additional animals will be dosed at 5 mg/kg. Because there will be a high risk of mortality, these animals should be dosed in a sequential manner to protect animal welfare. The time interval between dosing each animal should be sufficient to establish that the previous animal is likely to survive. If a second death occurs, the dosing sequence will be immediately terminated and no further animals will be dosed. Because the occurrence of a second death (irrespective of the number of animals tested at the time of termination) falls into outcome A (two or more deaths), the classification rule of Appendix 2 at the 5 mg/kg fixed dose is followed (Category 1 if there are two or more deaths or Category 2 if there is no more than one death). In addition, Appendix 4 gives guidance on the classification in the EU system until the new GHS is implemented.

1.5.3.   Main study

1.5.3.1.   Numbers of animals and dose levels

The action to be taken following testing at the starting dose level is indicated by the flowcharts in Appendix 2. One of three actions will be required; either stop testing and assign the appropriate hazard classification class, test at a higher fixed dose or test at a lower fixed dose. However, to protect animals, a dose level that caused death in the sighting study will not be revisited in the main study (see Appendix 2). Experience has shown that the most likely outcome at the starting dose level will be that the substance can be classified and no further testing will be necessary.

A total of five animals of one sex will normally be used for each dose level investigated. The five animals will be made up of one animal from the sighting study dosed at the selected dose level together with an additional four animals (except, unusually, if a dose level used on the main study was not included in the sighting study).

The time interval between dosing at each level is determined by the onset, duration, and severity of toxic signs. Treatment of animals at the next dose should be delayed until one is confident of survival of the previously dosed animals. A period of three or four days between dosing at each dose level is recommended, if needed, to allow for the observation of delayed toxicity. The time interval may be adjusted as appropriate, e.g. in case of inconclusive response.

When the use of an upper fixed dose of 5 000 mg/kg is considered, the procedure outlined in Appendix 3 should be followed (see also section 1.6.2).

1.5.3.2.   Limit test

The limit test is primarily used in situations where the experimenter has information indicating that the test material is likely to be nontoxic, i.e., having toxicity only above regulatory limit doses. Information about the toxicity of the test material can be gained from knowledge about similar tested compounds or similar tested mixtures or products, taking into consideration the identity and percentage of components known to be of toxicological significance. In those situations where there is little or no information about its toxicity, or in which the test material is expected to be toxic, the main test should be performed.

Using the normal procedure, a sighting study starting dose of 2 000 mg/kg (or exceptionally 5 000 mg/kg) followed by dosing of a further four animals at this level serves as a limit test for this guideline.

1.6.   OBSERVATIONS

Animals are observed individually after dosing at least once during the first 30 minutes, periodically during the first 24 hours, with special attention given during the first four hours, and daily thereafter, for a total of 14 days, except where they need to be removed from the study and humanely killed for animal welfare reasons or are found dead. However, the duration of observation should not be fixed rigidly. It should be determined by the toxic reactions, time of onset and length of recovery period, and may thus be extended when considered necessary. The times at which signs of toxicity appear and disappear are important, especially if there is a tendency for toxic signs to be delayed (11). All observations are systematically recorded, with individual records being maintained for each animal.

Additional observations will be necessary if the animals continue to display signs of toxicity. Observations should include changes in skin and fur, eyes and mucous membranes, and also respiratory, circulatory, autonomic and central nervous systems, and somatomotor activity and behaviour pattern. Attention should be directed to observations of tremors, convulsions, salivation, diarrhoea, lethargy, sleep and coma. The principles and criteria summarised in the Humane Endpoints Guidance Document should be taken into consideration (8). Animals found in a moribund condition and animals showing severe pain or enduring signs of severe distress should be humanely killed. When animals are killed for humane reasons or found dead, the time of death should be recorded as precisely as possible.

1.6.1.   Body weight

Individual weights of animals should be determined shortly before the test substance is administered and at least weekly thereafter. Weight changes should be calculated and recorded. At the end of the test surviving animals are weighed and then humanely killed.

1.6.2.   Pathology

All test animals (including those that die during the test or are removed from the study for animal welfare reasons) should be subjected to gross necropsy. All gross pathological changes should be recorded for each animal. Microscopic examination of organs showing evidence of gross pathology in animals surviving 24 or more hours after the initial dosing may also be considered because it may yield useful information.

2.   DATA

Individual animal data should be provided. Additionally, all data should be summarised in tabular form, showing for each test group the number of animals used, the number of animals displaying signs of toxicity, the number of animals found dead during the test or killed for humane reasons, time of death of individual animals, a description and the time course of toxic effects and reversibility, and necropsy findings.

3.   REPORTING

3.1.   TEST REPORT

The test report must include the following information, as appropriate:

Test substance:

 physical nature, purity, and, where relevant, physico-chemical properties (including isomerisation),

 identification data, including CAS number.

Vehicle (if appropriate):

 justification for choice of vehicle, if other than water.

Test animals:

 species/strain used,

 microbiological status of the animals, when known,

 number, age and sex of animals (including, where appropriate, a rationale for use of males instead of females),

 source, housing conditions, diet, etc.

Test conditions:

 details of test substance formulation, including details of the physical form of the material administered,

 details of the administration of the test substance including dosing volumes and time of dosing,

 details of food and water quality (including diet type/source, water source),

 the rationale for the selection of the starting dose.

Results:

 tabulation of response data and dose level for each animal (i.e. animals showing signs of toxicity including mortality, nature, severity and duration of effects),

 tabulation of body weight and body weight changes,

 individual weights of animals at the day of dosing, in weekly intervals thereafter, and at time of death or sacrifice,

 date and time of death if prior to scheduled sacrifice,

 time course of onset of signs of toxicity and whether these were reversible for each animal,

 necropsy findings and histopathological findings for each animal, if available.

Discussion and interpretation of results.

Conclusions.

4.   REFERENCES

(1) British Toxicology Society Working Party on Toxicity (1984) Special report: a new approach to the classification of substances and preparations on the basis of their acute toxicity. Human Toxicol., 3, p. 85-92.

(2) Van den Heuvel, M.J., Dayan, A.D. and Shillaker, R.O (1987) Evaluation of the BTS approach to the testing of substances and preparations for their acute toxicity. Human Toxicol.‚ 6, p. 279-291.

(3) Van den Heuvel, M.J., Clark, D.G., Fielder, R.J., Koundakjian, P.P., Oliver, G.J.A., Pelling, D., Tomlinson, N.J. and Walker, A.P (1990) The international validation of a fixed-dose procedure as an alternative to the classical LD50 test. Fd. Chem. Toxicol. 28, p. 469-482.

(4) Whitehead, A. and Curnow, R.N (1992) Statistical evaluation of the fixed-dose procedure. Fd. Chem. Toxicol., 30, p. 313-324.

(5) Stallard, N. and Whitehead, A (1995) Reducing numbers in the fixed-dose procedure. Human Exptl. Toxicol. 14, p. 315-323.

(6) Stallard, N., Whitehead, A and Ridgeway, P. (2002) Statistical evaluation of the revised fixed dose procedure. Hum. Exp. Toxicol., 21, p. 183-196.

(7) OECD (2001) Guidance Document on Acute Oral Toxicity Testing. Environmental Health and Safety Monograph Series on Testing and Assessment No 24. Paris

(8) OECD (2000) Guidance Document on the Recognition, Assessment and Use of Clinical Signs as Humane Endpoints for Experimental Animals Used in Safety Evaluation. Environmental Health and Safety Monograph Series on Testing and Assesment No 19.

(9) OECD (1998) Harmonised Integrated Hazard Classification for Human Health and Environmental Effects of Chemical Substances as endorsed by the 28th Joint Meeting of the Chemicals Committee and the Working Party on Chemicals in November 1998, Part 2, p. 11 [http://webnet1.oecd.org/oecd/pages/home/displaygeneral/0,3380, EN-documents-521-14-no-24-no-0,FF.html].

(10) Lipnick, R.L., Cotruvo, J.A., Hill, R.N., Bruce, R.D., Stitzel, K.A., Walker, A.P., Chu, I., Goddard, M., Segal, L., Springer, J.A. and Myers, R.C (1995) Comparison of the Up-and-Down, Conventional LD50, and Fixed-Dose Acute Toxicity Procedures. Fd. Chem. Toxicol. 33, p. 223-231.

(11) Chan P.K and A. W Hayes (1994) Chapter 16 Acute Toxicity and Eye Irritation. In: Principles and Methods of Toxicology. 3rd Edition. A.W. Hayes, Editor. Raven Press Ltd. New York, USA.

Appendix 1

FLOW CHART FOR THE SIGHTING STUDY

Starting dose: 5 mg/kgSTART1 animal 5 mg/kg1 animal 50 mg/kg1 animal 300 mg/kg1 animal 2000 mg/kgClassify GHSCategory 1*Main study starting Dose (mg/kg):starting dose: 50 mg/kgSTART1 animal 5 mg/kg1 animal 50 mg/kg1 animal 300 mg/kg1 animal 2000 mg/kgClassify GHSCategory 1*Main study starting Dose (mg/kg):Outcomedeathevident toxicityno evident toxicity and no death* for outcome at 5 mg/kg there is an optional supplementary procedure to confirm the GHS classification: see section 1.5.2

Starting dose: 300 mg/kgSTART1 animal 5 mg/kg1 animal 50 mg/kg1 animal 300 mg/kg1 animal 2000 mg/kgClassify GHSCategory 1*Main study starting Dose (mg/kg):starting dose: 2000 mg/kgSTART1 animal 5 mg/kg1 animal 50 mg/kg1 animal 300 mg/kg1 animal 2000 mg/kgClassify GHSCategory 1*Main study starting Dose (mg/kg):Outcomedeathevident toxicityno evident toxicity and no death* for outcome at 5 mg/kg there is an optional supplementary procedure to confirm the GHS classification: see section 1.5.2

Appendix 2

FLOW CHART FOR THE MAIN STUDY

Starting dose: 5 mg/kgSTART5 animals 5 mg/kg5 animals 50 mg/kg*5 animals 300 mg/kg5 animals 2000 mg/kgClassify GHSCategory5/UnclassifiedStarting dose: 50 mg/kgSTART5 animals 5 mg/kg5 animals 50 mg/kg5 animals 300 mg/kg*5 animals 2000 mg/kgClassify GHSCategory5/UnclassifiedOutcome≥ 2 deaths≥ 1 with evident toxicity and / or 1 deathNo evident toxicity and no deathGroup sizeThe 5 animals in each main study group will include any animal tested at that dose level in the sighting study* Animal welfare overrideIf this dose level caused death in the sighting study, then no further animals will be tested. Go directly to outcome

Starting dose: 300 mg/kgSTART5 animals 5 mg/kg5 animals 50 mg/kg5 animals 300 mg/kg5 animals 2000 mg/kg*Classify GHSCategory5/Unclassifiedstarting dose: 2000 mg/kgSTART5 animals 5 mg/kg5 animals 50 mg/kg5 animals 300 mg/kg5 animals 2000 mg/kgClassify GHSCategory5/UnclassifiedOutcome≥ 2 deaths≥ 1 with evident toxicity and / or 1 deathNo evident toxicity and no deathGroup sizeThe 5 animals in each main study group will include any animal tested at that dose level in the sighting study* Animal welfare overrideIf this dose level caused death in the sighting study, then no further animals will be tested. Go directly to outcome

Appendix 3

CRITERIA FOR CLASSIFICATION OF TEST SUBSTANCES WITH EXPECTED LD50 VALUES EXCEEDING 2 000 MG/KG WITHOUT THE NEED FOR TESTING.

Criteria for hazard Category 5 are intended to enable the identification of test substances which are of relatively low acute toxicity hazard but which, under certain circumstances may present a danger to vulnerable populations. These substances are anticipated to have an oral or dermal LD50 in the range of 2 000-5 000 mg/kg or equivalent doses for other routes. Test substances could be classified in the hazard category defined by: 2 000 mg/kg < LD50 < 5 000 mg/kg (Category 5 in the GHS) in the following cases:

(a) if directed to this category by any of the testing schemes of Appendix 2, based on mortality incidences

(b) if reliable evidence is already available that indicates the LD50 to be in the range of Category 5 values; or other animal studies or toxic effects in humans indicate a concern for human health of an acute nature;

(c) through extrapolation, estimation or measurement of data if assignment to a more hazardous class is not warranted; and

 reliable information is available indicating significant toxic effects in humans, or

 any mortality is observed when tested up to Category 4 values by the oral route, or

 where expert judgement confirms significant clinical signs of toxicity, when tested up to Category 4 values, except for diarrhoea, piloerection or an ungroomed appearance, or

 where expert judgement confirms reliable information indicating the potential for significant acute effects from the other animal studies.

TESTING AT DOSES ABOVE 2 000 MG/KG

Exceptionally, and only when justified by specific regulatory needs, the use of an additional upper fixed dose level of 5 000 mg/kg may be considered. Recognising the need to protect animal welfare, testing at 5 000 mg/kg is discouraged and should only be considered when there is a strong likelihood that the results of such a test would have a direct relevance for protecting animal or human health (9).

Sighting study

The decision rules governing the sequential procedure presented in Appendix 1 are extended to include a 5 000 mg/kg dose level. Thus, when a sighting study starting dose of 5 000 mg/kg is used outcome A (death) will require a second animal to be tested at 2 000 mg/kg; outcomes B and C (evident toxicity or no toxicity) will allow the selection of 5 000 mg/kg as the main study starting dose. Similarly, if a starting dose other than 5 000 mg/kg is used then testing will progress to 5 000 mg/kg in the event of outcomes B or C at 2 000 mg/kg; a subsequent 5 000 mg/kg outcome A will dictate a main study starting dose of 2 000 mg/kg and outcomes B and C will dictate a main study starting dose of 5 000 mg/kg.

Main study

The decision rules governing the sequential procedure presented in Appendix 2 are extended to include a 5 000 mg/kg dose level. Thus, when a main study starting dose of 5 000 mg/kg is used, outcome A (≥ 2 deaths) will require the testing of a second group at 2 000 mg/kg; outcome B (evident toxicity and/or ≤ 1 death) or C (no toxicity) will result in the substance being unclassified according to GHS. Similarly, if a starting dose other than 5 000 mg/kg is used then testing will progress to 5 000 mg/kg in the event of outcome C at 2 000 mg/kg; a subsequent 5 000 mg/kg outcome A will result in the substance being assigned to GHS Category 5 and outcomes B or C will lead to the substance being unclassified.

Appendix 4

TEST METHOD B.1 bis

Guidance on classification according to the EU scheme to cover the transition period until full implementation of the Globally Harmonised Classification System (GHS) (taken from reference (8))

Starting dose: 5 mg/kgSTART5 animals 5 mg/kg5 animals 50 mg/kg5 animals 300 mg/kg5 animals 2000 mg/kgClassify EUstarting dose: 50 mg/kgSTART5 animals 5 mg/kg5 animals 50 mg/kg5 animals 300 mg/kg *5 animals 2000 mg/kgClassify EUOutcome≥ 2 deaths≥ 1 with evident toxicity and/or 1 deathNo evident toxicity and no deathT+ = very toxicT = toxicH = harmfulU = unclassified* Animal welfare override If this dose level caused death in the sighting study, then no futher animals will be tested. Go directely to outcomeGroup size The 5 animals in each main study group will include any animal tested at that dose level in the study

Starting dose: 300 mg/kgSTART5 animals 5 mg/kg5 animals 50 mg/kg5 animals 300 mg/kg5 animals 2000 mg/kg*Classify EUStarting dose: 2000 mg/kgSTART5 animals 5 mg/kg5 animals 50 mg/kg5 animals 300 mg/kg5 animals 2000 mg/kgClassify EUOutcome≥ 2 deaths≥ 1 with evident toxicity and / or 1 deathNo evident toxicity and no deathT+ = very toxicT = toxicH = harmfulU + unclassifiedGroup sizeThe 5 animals in each main study group will include any animal tested at that dose level in the sighting study* Animal welfare overrideIf this dose level caused death in the sighting study, then no further animals will be tested. Go directly to outcome

B.1 tris.   ACUTE ORAL TOXICITY — ACUTE TOXIC CLASS METHOD

1.   METHOD

This test method is equivalent to OECD TG 423 (2001)

1.1.   INTRODUCTION

The acute toxic class method (1) set out in this test is a stepwise procedure with the use of three animals of a single sex per step. Depending on the mortality and/or the moribund status of the animals, on average two to four steps may be necessary to allow judgement on the acute toxicity of the test substance. This procedure is reproducible, uses very few animals and is able to rank substances in a similar manner to the other acute toxicity testing methods. The acute toxic class method is based on biometric evaluations (2)(3)(4)(5) with fixed doses, adequately separated to enable a substance to be ranked for classification purposes and hazard assessment. The method as adopted in 1996 was extensively validated in vivo against LD50 data obtained from the literature, both nationally (6) and internationally (7).

Guidance on the selection of the most appropriate test method for a given purpose can be found in the Guidance Document on Acute Oral Toxicity Testing (8). This Guidance Document also contains additional information on the conduct and interpretation of testing method B.1tris.

Test substances, at doses that are known to cause marked pain and distress due to corrosive or severely irritant actions, need not be administered. Moribund animals, or animals obviously in pain or showing signs of severe and enduring distress shall be humanely killed, and are considered in the interpretation of the test results in the same way as animals that died on test. Criteria for making the decision to kill moribund or severely suffering animals, and guidance on the recognition of predictable or impending death, are the subject of a separate Guidance Document (9).

The method uses pre-defined doses and the results allow a substance to be ranked and classified according to the Globally Harmonised System for the classification of chemicals which cause acute toxicity (10).

In principle, the method is not intended to allow the calculation of a precise LD50, but does allow for the determination of defined exposure ranges where lethality is expected since death of a proportion of the animals is still the major endpoint of this test. The method allows for the determination of an LD50 value only when at least two doses result in mortality higher than 0 % and lower than 100 %. The use of a selection of pre-defined doses, regardless of test substance, with classification explicitly tied to number of animals observed in different states improves the opportunity for laboratory to laboratory reporting consistency and repeatability.

The testing laboratory should consider all available information on the test substance prior to conducting the study. Such information will include the identity and chemical structure of the substance; its physico-chemical properties; the result of any other in vivo or in vitro toxicity tests on the substance; toxicological data on the structurally related substances; and the anticipated use(s) of the substance. This information is necessary to satisfy all concerned that the test is relevant for the protection of human health and will help in the selection of the most appropriate starting dose.

1.2.   DEFINITIONS

Acute oral toxicity: refers to those adverse effects occurring following oral administration of a single dose of a substance or multiple doses given within 24 hours.

Delayed death: means that an animal does not die or appear moribund within 48 hours but dies later during the 14-day observation period.

Dose: is the amount of test substance administered. Dose is expressed as weight of test substance per unit weight of test animal (e.g. mg/kg).

GHS: Globally Harmonised Classification System for Chemical Substances and Mixtures. A joint activity of OECD (human health and the environment), UN Committee of Experts on Transport of Dangerous Goods (physical-chemical properties) and ILO (hazard communication) and coordinated by the Interorganisation Programme for the Sound Management of Chemicals (IOMC).

Impending death: when moribund state or death is expected prior to the next planned time of observation. Signs indicative of this state in rodents could include convulsions, lateral position, recumbence and tremor (See the Humane Endpoint Guidance Document (9) for more details).

LD 50 (median lethal oral dose): is a statistically derived single dose of a substance that can be expected to cause death in 50 % of animals when administered by the oral route. The LD50 value is expressed in terms of weight of test substance per unit weight of test animal (mg/kg).

Limit dose: refers to a dose at an upper limitation on testing (2 000 or 5 000 mg/kg).

Moribund status: being in a state of dying or inability to survive, even if treated (See the Humane Endpoint Guidance Document (9) for more details).

Predictable death: presence of clinical signs indicative of death at a known time in the future before the planned end of the experiment; for example: inability to reach water or food. (See the Humane Endpoint Guidance Document (9) for more details).

1.3.   PRINCIPLE OF THE TEST

It is the principle of the test that, based on a stepwise procedure with the use of a minimum number of animals per step, sufficient information is obtained on the acute toxicity of the test substance to enable its classification. The substance is administered orally to a group of experimental animals at one of the defined doses. The substance is tested using a stepwise procedure, each step using three animals of a single sex (normally females). Absence or presence of compound-related mortality of the animals dosed at one step will determine the next step, i.e.;

 no further testing is needed,

 dosing of three additional animals, with the same dose,

 dosing of three additional animals at the next higher or the next lower dose level.

Details of the test procedure are described in Appendix 1. The method will enable a judgement with respect to classifying the test substance to one of a series of toxicity classes defined by fixed LD50 cut-off values.

1.4.   DESCRIPTION OF THE METHOD

1.4.1.   Selection of animal species

The preferred rodent species is the rat, although other rodent species may be used. Normally females are used (9). This is because literature surveys of conventional LD50 tests show that, although there is little difference in sensitivity between the sexes, in those cases where differences are observed females are generally slightly more sensitive (11). However if knowledge of the toxicological or toxicokinetic properties of structurally related chemicals indicates that males are likely to be more sensitive, then this sex should be used. When the test is conducted in males, adequate justification should be provided.

Healthy young adult animals of commonly used laboratory strains should be employed. Females should be nulliparous and non-pregnant. Each animal, at the commencement of its dosing, should be between eight and 12 weeks old and its weight should fall in an interval within ± 20 % of the mean weight of any previously dosed animals.

1.4.2.   Housing and feeding conditions

The temperature in the experimental animal room should be 22 oC (± 3 oC). Although the relative humidity should be at least 30 % and preferably not exceed 70 % other than during room cleaning the aim should be 50-60 %. Lighting should be artificial, the sequence being 12 hours light, 12 hours dark. For feeding, conventional laboratory diets may be used with an unlimited supply of drinking water. Animals may be group-caged by dose, but the number of animals per cage must not interfere with clear observations of each animal.

1.4.3.   Preparation of animals

The animals are randomly selected, marked to permit individual identification, and kept in their cages for at least five days prior to dosing to allow for acclimatisation to the laboratory conditions.

1.4.4.   Preparation of doses

In general, test substances should be administered in a constant volume over the range of doses to be tested by varying the concentration of the dosing preparation. Where a liquid end product or mixture is to be tested however, the use of the undiluted test substance, i.e. at a constant concentration, may be more relevant to the subsequent risk assessment of that substance, and is a requirement of some regulatory authorities. In either case, the maximum dose volume for administration must not be exceeded. The maximum volume of liquid that can be administered at one time depends on the size of the test animal. In rodents, the volume should not normally exceed 1 ml/100 g of body weight: however in the case of aqueous solutions 2 ml/100 g body weight can be considered. With respect to the formulation of the dosing preparation, the use of an aqueous solution/suspension/emulsion is recommended wherever possible, followed in order of preference by a solution/suspension/emulsion in oil (e.g. corn oil) and then possibly solution in other vehicles. For vehicles other than water the toxicological characteristics of the vehicle should be known. Doses must be prepared shortly prior to administration unless the stability of the preparation over the period during which it will be used is known and shown to be acceptable.

1.5.   PROCEDURE

1.5.1.   Administration of doses

The test substance is administered in a single dose by gavage using a stomach tube or a suitable intubation canula. In the unusual circumstance that a single dose is not possible, the dose may be given in smaller fractions over a period not exceeding 24 hours.

Animals should be fasted prior to dosing (e.g. with the rat, food but not water should be withheld overnight, with the mouse, food but not water should be withheld for three or four hours). Following the period of fasting, the animals should be weighed and the test substance administered. After the substance has been administered, food may be withheld for a further three or fours hours in rats or one or two hours in mice. Where a dose is administered in fractions over a period it may be necessary to provide the animals with food and water depending on the length of the period.

1.5.2.   Number of animals and dose levels

Three animals are used for each step. The dose level to be used as the starting dose is selected from one of four fixed levels, 5, 50, 300 and 2 000 mg/kg body weight. The starting dose level should be that which is most likely to produce mortality in some of the dosed animals. The flowcharts of Appendix 1 describe the procedure that should be followed for each of the starting doses. In addition, Appendix 4 gives guidance on the classification in the EU system until the new GHS is implemented.

When available information suggests that mortality is unlikely at the highest starting dose level (2 000 mg/kg body weight), then a limit test should be conducted. When there is no information on a substance to be tested, for animal welfare reasons it is recommended to use the starting dose of 300 mg/kg body weight.

The time interval between treatment groups is determined by the onset, duration, and severity of toxic signs. Treatment of animals at the next dose should be delayed until one is confident of survival of the previously dosed animals.

Exceptionally, and only when justified by specific regulatory needs, the use of additional upper dose level of 5 000 mg/kg body weight may be considered (see Appendix 2). For reasons of animal welfare concern, testing of animals in GHS Category 5 ranges (2 000-5 000 mg/kg) is discouraged and should only be considered when there is a strong likelihood that the results of such a test would have a direct relevance for protecting human or animal health or the environment.

1.5.3.   Limit test

The limit test is primarily used in situations where the experimenter has information indicating that the test material is likely to be non-toxic, i.e., having toxicity only above regulatory limit doses. Information about the toxicity of the test material can be gained from knowledge about similar tested compounds or similar tested mixtures or products, taking into consideration the identity and percentage of components known to be of toxicological significance. In those situations where there is little or no information about its toxicity, or in which the test material is expected to be toxic, the main test should be performed.

A limit test at one dose level of 2 000 mg/kg body weight may be carried out with six animals (three animals per step). Exceptionally a limit test at one dose level of 5 000 mg/kg may be carried out with three animals (see Appendix 2). If test substance-related mortality is produced, further testing at the next lower level may need to be carried out.

1.6.   OBSERVATIONS

Animals are observed individually after dosing at least once during the first 30 minutes, periodically during the first 24 hours, with special attention given during the first four hours, and daily thereafter, for a total of 14 days, except where they need to be removed from the study and humanely killed for animal welfare reasons or are found dead. However, the duration of observation should not be fixed rigidly. It should be determined by the toxic reactions, time of onset and length of recovery period, and may thus be extended when considered necessary. The times at which signs of toxicity appear and disappear are important, especially if there is a tendency for toxic signs to be delayed (12). All observations are systematically recorded with individual records being maintained for each animal.

Additional observations will be necessary if the animals continue to display signs of toxicity. Observations should include changes in skin and fur, eyes and mucous membranes, and also respiratory, circulatory, autonomic and central nervous systems, and somatomotor activity and behaviour pattern. Attention should be directed to observations of tremors, convulsions, salivation, diarrhoea, lethargy, sleep and coma. The principles and criteria summarised in the Humane Endpoints Guidance Document (9) should be taken into consideration. Animals found in a moribund condition and animals showing severe pain or enduring signs of severe distress should be humanely killed. When animals are killed for humane reasons or found dead, the time of death should be recorded as precisely as possible.

1.6.1.   Body weight

Individual weights of animals should be determined shortly before the test substance is administered, and at least weekly thereafter. Weight changes should be calculated and recorded. At the end of the test surviving animals are weighed and humanely killed.

1.6.2.   Pathology

All test animals (including those that die during the test or are removed from the study for animal welfare reasons) should be subjected to gross necropsy. All gross pathological changes should be recorded for each animal. Microscopic examination of organs showing evidence of gross pathology in animals surviving 24 or more hours may also be considered because it may yield useful information.

2.   DATA

Individual animal data should be provided. Additionally, all data should be summarised in tabular form, showing for each test group the number of animals used, the number of animals displaying signs of toxicity, the number of animals found dead during the test or killed for humane reasons, time of death of individual animals, a description and the time course of toxic effects and reversibility, and necropsy findings.

3.   REPORTING

3.1.   Test report

The test report must include the following information, as appropriate:

Test substance:

 physical nature, purity, and, where relevant, physico-chemical properties (including isomerisation),

 identification data, including CAS number.

Vehicle (if appropriate):

 justification for choice of vehicle, if other than water.

Test animals:

 species/strain used,

 microbiological status of the animals, when known,

 number, age, and sex of animals (including, where appropriate, a rationale for the use of males instead of females),

 source, housing conditions, diet, etc.

Test conditions:

 details of test substance formulation including details of the physical form of the material administered,

 details of the administration of the test substance including dosing volumes and time of dosing,

 details of food and water quality (including diet type/source, water source),

 the rationale for the selection of the starting dose.

Results:

 tabulation of response data and dose level for each animal (i.e. animals showing signs of toxicity including mortality; nature, severity, and duration of effects),

 tabulation of body weight and body weight changes,

 individual weights of animals at the day of dosing, in weekly intervals thereafter, and at the time of death or sacrifice,

 date and time of death if prior to scheduled sacrifice,

 time course of onset of signs of toxicity, and whether these were reversible for each animal,

 necropsy findings and histopathological findings for each animal, if available.

Discussion and interpretation of results.

Conclusions.

4.   REFERENCES

(1) Roll R., Höfer-Bosse Th. And Kayser D (1986) New Perspectives in Acute Toxicity Testing of Chemicals. Toxicol. Lett., Suppl. 31, p. 86.

(2) Roll R., Riebschläger M., Mischke U. and Kayser D (1989) Neue Wege zur Bestimmung der akuten Toxizität von Chemikalien. Bundesgesundheitsblatt 32, p. 336-341.

(3) Diener W., Sichha L., Mischke U., Kayser D. and Schlede E (1994) The Biometric Evaluation of the Acute-Toxic-Class Method (Oral). Arch. Toxicol. 68, p. 559-610.

(4) Diener W., Mischke U., Kayser D. and Schlede E., (1995) The Biometric Evaluation of the OECD Modified Version of the Acute-Toxic-Class Method (Oral). Arch. Toxicol. 69, p. 729-734.

(5) Diener W., and Schlede E., (1999) Acute Toxicity Class Methods: Alterations to LD/LC50 Tests. ALTEX 16, p. 129-134.

(6) Schlede E., Mischke U., Roll R. and Kayser D., (1992). A National Validation Study of the Acute-Toxic- Class Method — An Alternative to the LD50 Test. Arch. Toxicol. 66, 455-470.

(7) Schlede E., Mischke U., Diener W. and Kayser D., (1994) The International Validation Study of the Acute-Toxic-Class Method (Oral). Arch. Toxicol. 69, p. 659-670.

(8) OECD, (2001) Guidance Document on Acute Oral Toxicity Testing. Environmental Health and Safety Monograph Series on Testing and Assessment No 24. Paris.

(9) OECD, (2000) Guidance Document on the Recognition, Assessment and Use of Clinical Signs as Humane Endpoints for Experimental Animals Used in Safety Evaluation. Environmental Health and Safety Monograph Series on Testing and Assessment No 19.

(10) OECD, (1998) Harmonised Integrated Hazard Classification System For Human Health And Environmental Effects Of Chemical Substances as endorsed by the 28th Joint Meeting of the Chemicals Committee and the Working Party on Chemicals in November 1998, Part 2, p. 11 [http://webnet1.oecd.org/oecd/pages/home/displaygeneral/0,3380, EN-documents-521-14-no-24-no-0,FF.html].

(11) Lipnick R. L., Cotruvo, J.A., Hill R. N., Bruce R. D., Stitzel K. A., Walker A. P., Chu I.; Goddard M., Segal L., Springer J. A. and Myers R. C. (1995) Comparison of the Up-and Down, Conventional LD50, and Fixed Dose Acute Toxicity Procedures. Fd. Chem. Toxicol 33, p. 223-231.

(12) Chan P.K. and A.W. Hayes. (1994). Chap. 16. Acute Toxicity and Eye Irritancy. Principles and Methods of Toxicology. Third Edition. A.W. Hayes, Editor. Raven Press, Ltd., New York, USA.

Appendix 1

PROCEDURE TO BE FOLLOWED FOR EACH OF THE STARTING DOSES

GENERAL REMARKS

For each starting dose, the respective testing schemes as included in this Appendix outline the procedure to be followed.

 Appendix 1 a: starting dose is 5 mg/kg bw,

 Appendix 1 b: starting dose is 50 mg/kg bw,

 Appendix 1 c: starting dose is: 300 mg/kg bw,

 Apendix 1 d: starting dose is: 2 000 mg/kg bw.

Depending on the number of humanely killed or dead animals, the test procedure follows the indicated arrows.

Appendix 1A

TEST PROCEDURE WITH A STARTING DOSE OF 5 MG/KG BODY WEIGHT

Start5 mg/kg 3 animals50 mg/kg 3 animals300 mg/kg 3 animals2000 mg/kg 3 animals5 mg/kg 3 animals50 mg/kg 3 animals300 mg/kg 3 animals2000 mg/kg 3 animalsGHSCategory 1> 0 - 5Category 2> 5 - 50Category 3> 50 - 300Category 4> 300 - 2000Category 5> 2000 - 5000∞LD50 cut-off mg/kg b.w.- per step 3 animals of a single sex (normally females) are used- 0, 1, 2, 3: Number of moribund or dead animals at each step- GHS: Globally Harmonised Classification System (mg/kg b.w.)- ∞: unclassified- Testing at 5000 mg/kg b.w.: see Appendix 2

Appendix 1B

TEST PROCEDURE WITH A STARTING DOSE OF 50 MG/KG BODY WEIGHT

Start5 mg/kg 3 animals50 mg/kg 3 animals300 mg/kg 3 animals2000 mg/kg 3 animals5 mg/kg 3 animals50 mg/kg 3 animals300 mg/kg 3 animals2000 mg/kg 3 animalsGHSCategory 1> 0 - 5Category 2> 5 - 50Category 3> 50 - 300Category 4> 300 - 2000Category 5> 2000 - 5000∞3 (at 50) at the 1st stepotherLD50 cut-off mg/kg b.w.- per step 3 animals of a single sex (normally females) are used- 0, 1, 2, 3: Number of moribund or dead animals at each step- GHS: Globally Harmonised Classification System (mg/kg b.w.)- ∞: unclassified- Testing at 5000 mg/kg b.w.: see Appendix 2

Appendix1C

TEST PROCEDURE WITH A STARTING DOSE OF 300 MG/KG BODY WEIGHT

Start5 mg/kg 3 animals50 mg/kg 3 animals300 mg/kg 3 animals2000 mg/kg 3 animals5 mg/kg 3 animals50 mg/kg 3 animals300 mg/kg 3 animals2000 mg/kg 3 animalsGHSCategory 1> 0 - 5Category 2> 5 - 50Category 3> 50 - 300Category 4> 300 - 2000Category 5> 2000 - 5000∞3 (at 50) at the 1st stepother3 (at 50) at the 1st stepotherLD50 cut-off mg/kg b.w.- per step 3 animals of a single sex (normally females) are used- 0, 1, 2, 3: Number of moribund or dead animals at each step- GHS: Globally Harmonised Classification System (mg/kg b.w.)- ∞: unclassified- Testing at 5000 mg/kg b.w.: see Appendix 2

Appendix 1D

TEST PROCEDURE WITH A STARTING DOSE OF 2 000 MG/KG BODY WEIGHT

Start5 mg/kg 3 animals50 mg/kg 3 animals300 mg/kg 3 animals2000 mg/kg 3 animals5 mg/kg 3 animals50 mg/kg 3 animals300 mg/kg 3 animals2000 mg/kg 3 animalsGHSCategory 1> 0 - 5Category 2> 5 - 50Category 3> 50 - 300Category 4> 300 - 2000Category 5> 2000 - 5000∞3 (at 50) at 1st stepother3 (at 300) at 1st stepother3 (at 2000) at 1st step2 (at 2000) at 1st stepotherLD50 cut-off mg/kg b.w.- per step 3 animals of a single sex (normally females) are used- 0, 1, 2, 3: Number of moribund or dead animals at each step- GHS: Globally Harmonised Classification System (mg/kg b.w.)- ∞: unclassified- Testing at 5000 mg/kg b.w.: see Appendix 2

Appendix 2

CRITERIA FOR CLASSIFICATION OF TEST SUBSTANCES WITH EXPECTED LD50 VALUES EXCEEDING 2 000 MG/KG WITHOUT THE NEED FOR TESTING

Criteria for hazard Category 5 are intended to enable the identification of test substances which are of relatively low acute toxicity hazard but which, under certain circumstances may present a danger to vulnerable populations. These substances are anticipated to have an oral or dermal LD50 in the range of 2 000-5 000 mg/kg or equivalent doses for other routes. The test substance should be classified in the hazard category defined by: 2 000 mg/kg < LD50 < 5 000 mg/kg (Category 5 in the GHS) in the following cases:

(a) If directed to this category by any of the testing schemes of Appendix 1a-1d, based on mortality incidences;

(b) if reliable evidence is already available that indicates the LD50 to be in the range of Category 5 values; or other animal studies or toxic effects in humans indicate a concern for human health of an acute nature;

(c) through extrapolation, estimation or measurement of data if assignment to a more hazardous class is not warranted; and

 reliable information is available indicating significant toxic effects in humans, or

 any mortality is observed when tested up to Category 4 values by the oral route, or

 where expert judgement confirms significant clinical signs of toxicity, when tested up to Category 4 values, except for diarrhoea, piloerection or an ungroomed appearance, or

 where expert judgement confirms reliable information indicating the potential for significant acute effects from the other animal studies.

TESTING AT DOSES ABOVE 2 000 MG/KG

Recognising the need to protect animal welfare, testing of animals in Category 5 (5 000 mg/kg) ranges is discouraged and should only be considered when there is a strong likelihood that results of such a test have a direct relevance for protecting human or animal health (10). No further testing should be conducted at higher dose levels.

When testing is required a dose of 5 000 mg/kg, only one step (i.e. three animals) is required. If the first animal dosed dies, then dosing proceeds at 2 000 mg/kg in accordance with the flowcharts in Appendix 1. If the first animal survives, two further animals are dosed. If only one of the three animals dies, the LD50 value is expected to exceed 5 000 mg/kg. If both animals die, then dosing proceeds at 2 000 mg/kg.

Appendix 3

TEST METHOD B.1 tris: Guidance on classififcation according to EU scheme to cover the transition period until full implementation of the Globally Harmonised Classification System (GHS) (taken from reference (8))

Start5 mg/kg3 animals50 mg/kg3 animals300 mg/kg3 animals2000 mg/kg3 animals5 mg/kg3 animals50 mg/kg3 animals300 mg/kg3 animals2000 mg/kg3 animalsGHSCategory 1> 0 - 5Category 2> 5 - 50Category 3> 50 - 300Category 4> 300 - 2000Category 5> 2000 - 5000∞LD50 cut-offmg/kg b. w.EU/chemicals Liquid pesticidesEU solid pesticidesUN liquidsUN solidsSwitzerlandUS EPA crkJapan PDSCACanada/WHMIS/US OSHAUS EPA pesticidesUS CPSCCanada pesticides- per step 3 animals of a single sex (normally female) are used- 0,1, 2, 3: Number of moribund or dead animals at each step- ∞: unclassified- GHS: Globally Harmonised Classification System (mg/kg b. w.)

Start5 mg/kg 3 animals50 mg/kg 3 animals300 mg/kg 3 animals2000 mg/kg 3 animals5 mg/kg 3 animals50 mg/kg 3 animals300 mg/kg 3 animals2000 mg/kg 3 animalsGHSCategory 1 > 0 - 5Category 2 > 5 - 50Category 3 > 50 - 300Category 4 > 300 - 2000Category 5 > 2000 - 50003*(at 50)otherLD50 cut-off mg/kg b. w.EU/chemicals Liquid pesticidesEU solid pesticidesUN liquidsUN solidsSwitzerlandUS EPA crkJapan PDSCACanada/WHMIS/US OSHAUS EPA pesticidesUS CPSCCanada pesticides- per step 3 animals of a single sex (normally female) are used- 0,1, 2, 3: Number of moribund or dead animals at each step- ∞: unclassified- *: at first step- GHS: Globally Harmonised Classification System (mg/kg b. w.)

Start5 mg/kg3 animals50 mg/kg3 animals300 mg/kg3 animals2000 mg/kg3 animals5 mg/kg3 animals50 mg/kg3 animals300 mg/kg3 animals2000 mg/kg3 animalsGHSCategory 1> 0 - 5Category 2> 5 - 50Category 3> 50 - 300Category 4> 300 - 2000Category 5> 2000 - 50003*(at 50)other3*(at 300)otherLD50 cut-offmg/kg b. w.EU/chemicals Liquid pesticidesEU solid pesticidesUN liquidsUN solidsSwitzerlandUS EPA crkJapan PDSCACanada/WHMIS/US OSHAUS EPA pesticidesUS CPSCCanada pesticides- per step 3 animals of a single sex (normally female) are used- 0,1,2,3: Number of moribund or dead animals at each step- ∞: unclassified- *: at first step- GHS: Globally Harmonised Classification System (mg/kg b. w.)

Start5 mg/kg3 animals50 mg/kg3 animals300 mg/kg3 animals2000 mg/kg3 animals5 mg/kg3 animals50 mg/kg3 animals300 mg/kg3 animals2000 mg/kg3 animalsGHSCategory 1> 0 - 5Category 2> 5 - 50Category 3> 50 - 300Category 4> 300 - 2000Category 5> 2000 - 50003*(at 50)other3*(at 300)other3*(at 2000)2*(at 2000)otherLD50 cut-offmg/kg b. w.EU/chemicals Liquid pesticidesEU solid pesticidesUN liquidsUN solidsSwitzerlandUS EPA crkJapan PDSCACanada/WHMIS/US OSHAUS EPA pesticidesUS CPSCCanada pesticides- per step 3 animals of a single sex (normally female) are used- 0, 1, 2, 3: Number of moribund or dead animals at each step- ∞: unclassified- *: at first step- GHS: Globally Harmonised Classification System (mg/kg b. w.)

B.2.   ACUTE TOXICITY (INHALATION)

1.   METHOD

1.1.   INTRODUCTION

It is useful to have preliminary information on the particle size distribution, the vapour pressure, the melting point, the boiling point, the flash point and explosivity (if applicable) of the substance.

See also General introduction Part B (A).

1.2.   DEFINITIONS

See General introduction Part B (B).

1.3.   REFERENCE SUBSTANCES

None.

1.4.   PRINCIPLE OF THE TEST METHOD

Several groups of experimental animals are exposed for a defined period to the test substance in graduated concentrations, one concentration being used per group. Subsequently observations of effects and deaths are made. Animals, which die during the test are necropsied and at the conclusion of the test surviving animals are necropsied.

Animals showing severe and enduring signs of distress and pain may need to be humanely killed. Dosing test substances in a way known to cause marked pain and distress due to corrosive or severe irritating properties need not be carried out.

1.5.   QUALITY CRITERIA

None.

1.6.   DESCRIPTION OF THE TEST METHOD

1.6.1.   Preparations

The animals are kept under the experimental housing and feeding conditions for at least five days prior to the experiment. Before the test healthy young animals are randomiseds and assigned to the required number of groups. They need not be subjected to simulated exposure unless this is indicated by the type of exposure apparatus being used.

Solid test substances may need to be micronised in order to achieve particles of an appropriate size.

Where necessary a suitable vehicle may be added to the test substance to help generate an appropriate concentration of the test substance in the atmosphere and a vehicle control group should then be used. If a vehicle or other additives are used to facilitate dosing, they should be known not to produce toxic effects. Historical data can be used if appropriate.

1.6.2.   Test conditions

1.6.2.1.   Experimental animals

Unless there are contra-indications the rat is the preferred species. Commonly used laboratory strains should be employed. For each sex, at the start of the test the range of weight variation in the animals used should not exceed ± 20 % of the appropriate mean value.

1.6.2.2.   Number and sex

At least 10 rodents (five female and five male) are used at each concentration level. The females should be nulliparous and non-pregnant.

Note: in acute toxicity tests with animals of a higher order than rodents, the use of smaller numbers should be considered. Doses should be carefully selected, and every effort should be made not to exceed moderately toxic doses. In such tests administration of lethal doses of the test substance should be avoided.

1.6.2.3.   Exposure concentrations

These should be sufficient in number, at least three, and spaced appropriately to produce test groups with a range of toxic effects and mortality rates. The data should be sufficient to produce a concentration mortality curve and, where possible, permit an acceptable determination of an LC50.1.6.2.4. Limit test

1.6.2.4.   Limit test

If an exposure of five male and five female test animals to 20 mg per litre of a gas or 5 rug per litre of an aerosol or a particulate for four hours (or where this is not possible due to the physical or chemical, including explosive, properties of the test substance, the maximum attainable concentration) produces no compound related mortality within 14 days further testing may not be considered necessary (18th ATP, dir. 93/21/EEC, Ll10/93)

1.6.2.5.   Exposure time

The period of exposure should be four hours.

1.6.2.6.   Equipment

The animals should be tested with inhalation equipment designed to sustain a dynamic airflow of at least 12 air changes per hour, to ensure an adequate oxygen content and an evenly distributed exposure atmosphere. Where a chamber is used its design should minimise crowding of the test animals and maximise their exposure by inhalation to the test substance. As a general rule to ensure stability of a chamber atmosphere the total ‘volume’ of the test animals should not exceed 5 % of the volume of the test chamber. Oro-nasal, head only, or whole body individual chamber exposure may be used; the first two will help to minimise the uptake of the test substance by other routes.

1.6.2.7.   Observation period

The observation period should be at least 14 days. However, the duration of observations should not be rigidly fixed. It should be determined by the toxic reactions, their rate of onset and the length of the recovery period; it may thus be extended when considered necessary. The time at which signs of toxicity appear and disappear and the time of death are important, especially if there is a tendency for deaths to be delayed.

1.6.3.   Procedure

Shortly before exposure, the animals are weighed, and then exposed to the test concentration in the designated apparatus for a period of four hours, after equilibration of the chamber concentration. Time for equilibration should be short. The temperature at which the test is performed should be maintained at 22 ± 3 oC. Ideally the relative humidity should be maintained between 30 % and 70 %, but in certain instances (e.g. tests of some aerosols) this may not be practicable. Maintenance of a slight negative pressure inside the chamber (≥ 5 mm of water) will prevent leakage of the test substance into the surrounding area. Food and water should be withheld during exposure. Suitable systems for the generation and monitoring of the test atmosphere should be used. The system should ensure that stable exposure conditions are achieved as rapidly as possible. The chamber should be designed and operated in such a way that a homogeneous distribution of the test atmosphere within the chamber is maintained.

Measurements or monitoring should be made:

(a) of the rate of air flow (continuously);

(b) of the actual concentration of the test substance measured in the breathing zone at least three times during exposure (some atmospheres, e.g. aerosols at high concentrations, may need more frequent monitoring). During the exposure period the concentration should not vary by more than ± 15 % of the mean value. However in the case of some aerosols, this level of control may not be achievable and a wider range would then be acceptable. For aerosols, particle size analysis should be performed as often as necessary (at least once per test group);

(c) of temperature and humidity, continuously if possible.

During and following exposure, observations are made and recorded systematically; individual records should be maintained for each animal. Observations should be made frequently during the first day. A careful clinical examination should be made at least once each working day, other observations should be made daily with appropriate actions taken to minimise loss of animals from the study, e.g. necropsy or refrigeration of those animals found dead and isolation or sacrifice of weak or moribund animals.

Observations should include changes in the skin and fur, eyes, mucous membranes, respiratory, circulatory, autonomic and central nervous systems, and somatomotor activity and behaviour pattern. Particular attention should be directed to observation of respiratory behaviour, tremors, convulsions, salivation, diarrhoea, lethargy, sleep and coma. The time of death should be recorded as precisely as possible. Individual weights of animals should be determined weekly after exposure, and at death.

Animals that die during the test and those surviving at the termination of the test are subjected to necropsy with particular reference to any changes in the upper and lower respiratory tract. All gross pathological changes should be recorded. Where indicated, tissues should be taken for histopathological examination.

2.   DATA

Data should be summarised in tabular form showing for each test group the number of animals at the start of the test, time of death of individual animals, number of animals displaying other signs of toxicity, description of toxic effects and necropsy findings. Changes in weight must be calculated and recorded when survival exceeds one day. Animals, which are humanely killed due to compound-related distress and pain are recorded as compound-related deaths. The LC50 should be determined by a recognised method. Data evaluation should include the relationship, if any, between the animal's exposure to the test substance and the incidence and severity of all abnormalities, including behavioural and clinical abnormalities, gross lesions, body weight changes, mortality and any other toxic effects.

3.   REPORTING

3.1.   TEST REPORT

The test report shall, if possible, include the following information:

 species, strain, source, environmental conditions, diet, etc.,

 test conditions: description of exposure apparatus, including design, type, dimensions, source of air, system for generating aerosols, method of conditioning air and the method of housing animals in a test chamber when this is used. The equipment for measuring temperature, humidity, and aerosol concentrations and particle size distribution should be described.

Exposure data

These should be tabulated and presented with mean values and a measure of variability (e.g. standard deviation) and shall, if possible, include:

(a) airflow rates through the inhalation equipment;

(b) temperature and humidity of the air;

(c) nominal concentrations (total amount of test substance fed into the inhalation equipment divided by volume of air);

(d) nature of vehicle, if used;

(e) actual concentrations in test breathing zone;

(f) The mass median aerodynamic diameter (MMAD) and the geometric standard deviation (GSD);

(g) equilibration period;

(h) exposure period;

 tabulation of response data by sex and exposure level (i.e. number of animals that died or were killed during the test, number of animals showing signs of toxicity, number of animals exposed),

 time of death during or following exposure, reasons and criteria used for humane killing of animals,

 all observations,

 LC50 value for each sex determined at the end of the observation period (with method of calculation specified),

 95 % confidence interval for the LC50 (where this can be provided),

 dose/mortality curve and slope (where permitted by the method of determination),

 necropsy findings,

 any histopathological findings,

 discussions of the results (particular attention should be given to the effect that humane killing of animals during the test may have on the calculated LC50 value),

 interpretation of the results.

3.2.   EVALUATION AND INTERPRETATION

See General introduction Part B (D).

4.   REFERENCES

See General introduction Part B (E).

B.3.   ACUTE TOXICITY (DERMAL)

1.   METHOD

1.1.   INTRODUCTION

See General introduction Part B (A).

1.2.   DEFINITION

See General introduction Part B (B).

1.3.   REFERENCE SUBSTANCES

None.

1.4.   PRINCIPLE OF THE TEST METHOD

The test substance is applied to the skin in graduated doses to several groups of experimental animals, one dose being used per group. Subsequently, observations of effects and deaths are made. Animals, which die during the test are necropsied and at the conclusion of the test surviving animals are necropsied.

Animals showing severe and enduring signs of distress and pain may need to be humanely killed. Dosing test substances in a way known to cause marked pain and distress due to corrosive or irritating properties need not be carried out.

1.5.   QUALITY CRITERIA

None.

1.6.   DESCRIPTION OF THE TEST METHOD

1.6.1.   Preparations

The animals are kept in their experimental cages under the experimental housing and feeding conditions for at least five days prior to the experiment. Before the test, healthy young adult animals are randomised and assigned to the treatment groups. Approximately 24 hours before the test, fur should be removed by clipping or shaving from the dorsal area of the trunk of the animals. When clipping or shaving the fur, care must be taken to avoid abrading the skin which could alter its permeability. Not less than 10 % of the body surface should be clear for the application of the test substance. When testing solids, which may be pulverised if appropriate, the test substance should be moistened sufficiently with water or, where necessary, a suitable vehicle to ensure good contact with the skin. When a vehicle is used, the influence of the vehicle on penetration of skin by the test substance should be taken into account. Liquid test substances are generally used undiluted.

1.6.2.   Test conditions

1.6.2.1.   Experimental animals

The adult rat or rabbit may be used. Other species may be used but their use would require justification. Commonly used laboratory strains should be employed. For each sex, at the start of the test the range of weight variation in the animals used should not exceed ± 20 % of the appropriate mean value.

1.6.2.2.   Number and sex

At least five animals are used at each dose level. They should all be of the same sex. If females are used, they should be nulliparous and non-pregnant. Where information is available demonstrating that a sex is markedly more sensitive, animals of this sex should be dosed.

Note: in acute toxicity tests with animals of a higher order than rodents, the use of smaller numbers should be considered. Doses should be carefully selected, and every effort should be made not to exceed moderately toxic doses. In such tests, administration of lethal doses of the test substance should be avoided.

1.6.2.3.   Dose levels

These should be sufficient in number, at least three, and spaced appropriately to produce test groups with a range of toxic effects and mortality rates. Any irritant or corrosive effects should be taken into account when deciding on dose levels. The data should be sufficient to produce a dose/response curve and, where possible, permit an acceptable determination of the LD50.

1.6.2.4.   Limit test

A limit test at one dose level of at least 2 000 mg/kg bodyweight may be carried out in a group of five male and five female animals, using the procedures described above. If compound-related mortality is produced, a full study may need to be considered.

1.6.2.5.   Observation period

The observation period should be at least 14 days. However, the duration of observation should not be rigidly fixed. It should be determined by the toxic reactions, their rate of onset and the length of the recovery period; it may thus be extended when considered necessary. The time at which signs of toxicity appear and disappear, their duration and the time of death are important, especially if there is a tendency for deaths to be delayed.

1.6.3.   Procedure

Animals should be caged individually. The test substance should be applied uniformly over an area, which is approximately 10 % of the total body surface area. With highly toxic substances the surface area covered may be less but as much of the area should be covered with a layer as thin and uniform as possible.

Test substances should be held in contact with the skin with a porous gauze dressing and non-irritating tape throughout a 24-hour exposure period. The test site should be further covered in a suitable manner to retain the gauze dressing and test substance and ensure that the animals cannot ingest the test substance. Restrainers may be used to prevent the ingestion of the test substance but complete immobilisation is not a recommended method.

At the end of the exposure period, residual test substance should be removed, where practicable, using water or some other appropriate method of cleansing the skin.

Observations should be recorded systematically as they are made. Individual records should be maintained for each animal. Observations should be made frequently during the first day. A careful clinical examination should be made at least once each working day, other observations should be made daily with appropriate actions taken to minimise loss of animals to the study, e.g. necropsy or refrigeration of those animals found dead and isolation or sacrifice of weak or moribund animals.

Observations should include changes in fur, treated skin, eyes and mucous membranes, and also respiratory, circulatory, autonomic and central nervous systems, and somatomotor activity and behaviour pattern. Particular attention should be directed to observations of tremors, convulsions, salivation, diarrhoea, lethargy, sleep and coma. The time of death must be recorded as precisely as possible. Animals that die during the test and those surviving at the termination of the test are subjected to necropsy. All gross pathological changes should be recorded. Where indicated, tissues should be taken for histopathological examination.

After completion of the study in one sex, at least one group of five animals of the other sex is dosed to establish that animals of this sex are not markedly more sensitive to the test substance. The use of fewer animals may be justified in individual circumstances. Where adequate information is available to demonstrate that animals of the sex tested are markedly more sensitive, testing in animals of the other sex may be dispensed with.

2.   DATA

Data should be summarised in tabular form, showing for each test group the number of animals at the start of the test, time of death of individual animals, number of animals displaying other signs of toxicity, description of toxic effects and necropsy findings. Individual weights of animals should be determined and recorded shortly before the test substance is applied, weekly thereafter, and at death; changes in weight should be calculated and recorded when survival exceeds one day. Animals, which are humanely killed due to compound-related distress and pain are recorded as compound-related deaths. The LD50 should be determined by a recognised method.

Data evaluation should include an evaluation of relationships, if any, between the animal's exposure to the test substance and the incidence and severity of all abnormalities, including behavioural and clinical abnormalities, gross lesions, body weight changes, mortality, and any other toxicological effects.

3.   REPORTING

3.1.   TEST REPORT

The test report shall, if possible, include the following information:

 species, strain, source, environmental conditions, diet, etc.,

 test conditions (including method of skin cleansing and type of dressing: occlusive or not occlusive),

 dose levels (with vehicle, if used, and concentrations),

 sex of animals dosed,

 tabulation of response data by sex and dose level (i.e. number of animals that died or were killed during the test, number of animals showing signs of toxicity, number of animals exposed),

 time of death after dosing, reasons and criteria used for humane killing of animals,

 all observations,

 LD50 value for the sex subjected to a full study, determined at 14 days with the method of determination specified,

 95 % confidence interval for the LD50 (where this can be provided),

 dose/mortality curve and slope where permitted by the method of determination,

 necropsy findings,

 any histopathological findings,

 results of any test on the other sex,

 discussion of results (particular attention should be given to the effect that humane killing of animals during the test may have on the calculated LD50 value),

 interpretation of the results.

3.2.   EVALUATION AND INTERPRETATION

See General introduction Part B (D).

4.   REFERENCES

See General introduction Part B (E).

B.4.   ACUTE TOXICITY: DERMAL IRRITATION/CORROSION

1.   METHOD

This method is equivalent to the OECD TG 404 (2002).

1.1.   INTRODUCTION

In the preparation of this updated method special attention was given to possible improvements in relation to animal welfare concerns and to the evaluation of all existing information on the test substance in order to avoid unnecessary testing in laboratory animals. This method includes the recommendation that prior to undertaking the described in vivo test for corrosion/irritation of the substance, a weight-of-the-evidence analysis be performed on the existing relevant data. Where insufficient data are available, they can be developed through application of sequential testing (1). The testing strategy includes the performance of validated and accepted in vitro tests and is provided as an Appendix to this method. In addition, where appropriate, the successive, instead of simultaneous, application of the three test patches to the animal in the initial in vivo test is recommended.

In the interest of both sound science and animal welfare, in vivo testing should not be undertaken until all available data relevant to the potential dermal corrosivity/irritation of the substance have been evaluated in a weight-of-the-evidence analysis. Such data will include evidence from existing studies in humans and/or laboratory animals, evidence of corrosivity/irritation of one or more structurally related substances or mixtures of such substances, data demonstrating strong acidity or alkalinity of the substance (2)(3), and results from validated and accepted in vitro or ex vivo tests (4)(5)(5a). This analysis should decrease the need for in vivo testing for dermal corrosivity/irritation of substances for which sufficient evidence already exists from other studies as to those two endpoints.

A preferred sequential testing strategy, which includes the performance of validated and accepted in vitro or ex vivo tests for corrosion/irritation, is included as an Appendix to this Method. The strategy was developed at, and unanimously recommended by the participants of, an OECD workshop (6), and has been adopted as the recommended testing strategy in the Globally Harmonised System for the Classification of Chemical Substances (GHS) (7). It is recommended that this testing strategy be followed prior to undertaking in vivo testing. For new substances it is the recommended a stepwise testing approach for developing scientifically sound data on the corrosivity/irritation of the substance. For existing substances with insufficient data on dermal corrosion/irritation, the strategy should be used to fill missing data gaps. The use of a different testing strategy or procedure, or a decision not to use a stepwise testing approach, should be justified.

If a determination of corrosivity or irritation cannot be made using a weight-of-the-evidence analysis, consistent with the sequential testing strategy, an in vivo test should be considered (see Appendix).

1.2.   DEFINITIONS

Dermal irritation: is the production of reversible damage of the skin following the application of a test substance for up to four hours.

Dermal corrosion: is the production of irreversible damage of the skin; namely, visible necrosis through the epidermis and into the dermis, following the application of a test substance for up to four hours. Corrosive reactions are typified by ulcers, bleeding, bloody scabs, and, by the end of observation at 14 days, by discoloration due to blanching of the skin, complete areas of alopecia, and scars. Histopathology should be considered to evaluate questionable lesions.

1.3.   PRINCIPLE OF THE TEST METHOD

The substance to be tested is applied in a single dose to the skin of an experimental animal; untreated skin areas of the test animal serve as the control. The degree of irritation/corrosion is read and scored at specified intervals and is further described in order to provide a complete evaluation of the effects. The duration of the study should be sufficient to evaluate the reversibility or irreversibility of the effects observed.

Animals showing continuing signs of severe distress and/or pain at any stage of the test should be humanely killed, and the substance assessed accordingly. Criteria for making the decision to humanely kill moribund and severely suffering animals can be found in reference (8).

1.4.   DESCRIPTION OF THE TEST METHOD

1.4.1.   Preparation for the in vivo test

1.4.1.1.   Selection of animal species

The albino rabbit is the preferable laboratory animal and healthy young adult rabbits are used. A rationale for using other species should be provided.

1.4.1.2.   Preparation of the animals

Approximately 24 hours before the test, fur should be removed by closely clipping the dorsal area of the trunk of the animals. Care should be taken to avoid abrading the skin, and only animals with healthy, intact skin should be used.

Some strains of rabbit have dense patches of hair that are more prominent at certain times of the year. Such areas of dense hair growth should not be used as test sites.

1.4.1.3.   Housing and feeding conditions

Animals should be individually housed. The temperature of the experimental animal room should be 20 oC (± 3 oC) for rabbits. Although the relative humidity should be at least 30 % and preferably not exceed 70 %, other than during room cleaning, the aim should be 50-60 %. Lighting should be artificial, the sequence being 12 hours light, 12 hours dark. For feeding, conventional laboratory diets may be used with an unrestricted supply of drinking water.

1.4.2.   Test procedure

1.4.2.1.   Application of the test substance

The test substance should be applied to a small area (approximately 6 cm2) of skin and covered with a gauze patch, which is held in place with non-irritating tape. In cases in which direct application is not possible (e.g. liquids or some pastes), the test substance should first be applied to the gauze patch, which is then applied to the skin. The patch should be loosely held in contact with the skin by means of a suitable semi-occlusive dressing for the duration of the exposure period. If the test substance is applied to the patch, it should be attached to the skin in such a manner that there is good contact and uniform distribution of the substance on the skin. Access by the animal to the patch and ingestion or inhalation of the test substance should be prevented.

Liquid test substances are generally used undiluted. When testing solids (which may be pulverised, if considered necessary), the test substance should be moistened with the smallest amount of water (or, where necessary, of another suitable vehicle) sufficient to ensure good skin contact. When vehicles other than water are used, the potential influence of the vehicle on irritation of the skin by the test substance should be minimal, if any.

At the end of the exposure period, which is normally four hours, residual test substance should be removed, where practicable, using water or an appropriate solvent without altering the existing response or the integrity of the epidermis.

1.4.2.2.   Dose level

A dose of 0,5 ml. of liquid or 0,5 g of solid or paste is applied to the test site.

1.4.2.3.   Initial test (in vivo dermal irritation/corrosion test using one animal)

It is strongly recommended that the in vivo test be performed initially using one animal, especially when the substance is suspected to have corrosion potential. This is in accordance with the sequential testing strategy (see Appendix 1).

When a substance has been judged to be corrosive on the basis of a weight-of-the-evidence analysis, no further animal testing is needed. For most substances suspected of being corrosive, further in vivo testing is normally not necessary. However, in those cases where additional data are felt warranted because of insufficient evidence, limited animal testing may be carried out using the following approach: up to three tests patches are applied sequentially to the animal. The first patch is removed after three minutes. If no serious skin reaction is observed, a second patch is applied and removed after one hour. If the observations at this stage indicate that exposure can humanely be allowed to extend to four hours, a third patch is applied and removed after four hours, and the response is graded.

If a corrosive effect is observed after any of the three sequential exposures, the test is immediately terminated. If a corrosive effect is not observed after the last patch is removed, the animal is observed for 14 days, unless corrosion develops at an earlier time point.

In those cases in which the test substance is not expected to produce corrosion but may be irritating, a single patch should be applied to one animal for four hours.

1.4.2.4.   Confirmatory test (in vivo dermal irritation test with additional animals)

If a corrosive effect is not observed in the initial test, the irritant or negative response should be confirmed using up to two additional animals, each with one patch, for an exposure period of four hours. If an irritant effect is observed in the initial test, the confirmatory test may be conducted in a sequential manner, or by exposing two additional animals simultaneously. In the exceptional case, in which the initial test is not conducted, two or three animals may be treated with a single patch, which is removed after four hours. When two animals are used, if both exhibit the same response, no further testing is needed. Otherwise, the third animal is also tested. Equivocal responses may need to be evaluated using additional animals.

1.4.2.5.   Observation period

The duration of the observation period should be sufficient to evaluate fully the reversibility of the effects observed. However, the experiment should be terminated at any time that the animal shows continuing signs of severe pain or distress. To determine the reversibility of effects, the animals should be observed up to 14 days after removal of the patches. If reversibility is seen before 14 days, the experiment should be terminated at that time.

1.4.2.6.   Clinical observations and grading of skin reactions

All animals should be examined for signs of erythema and oedema, and the responses scored at 60 minutes, and then at 24, 48 and 72 hours after patch removal. For the initial test in one animal, the test site is also examined immediately after the patch has been removed. Dermal reactions are graded and recorded according to the grades in the Table below. If there is damage to skin which cannot be identified as irritation or corrosion at 72 hours, observations may be needed until day 14 to determine the reversibility of the effects. In addition to the observation of irritation, all local toxic effects, such as defatting of the skin, and any systemic adverse effects (e.g. effects on clinical signs of toxicity and body weight), should be fully described and recorded. Histopathological examination should be considered to clarify equivocal responses.

The grading of skin responses is necessarily subjective. To promote harmonisation in grading of skin response and to assist testing laboratories and those involved in making and interpreting the observations, the personnel performing the observations need to be adequately trained in the scoring system used (see Table below). An illustrated guide for grading skin irritation and other lesions could be helpful (9).

2.   DATA

2.1.   PRESENTATION OF RESULTS

Study results should be summarised in tabular form in the final test report and should cover all items listed in section 3.1.

2.2.   EVALUATION OF RESULTS

The dermal irritation scores should be evaluated in conjunction with the nature and severity of lesions, and their reversibility or lack of reversibility. The individual scores do not represent an absolute standard for the irritant properties of a material, as other effects of the test material are also evaluated. Instead, individual scores should be viewed as reference values, which need to be evaluated in combination with all other observations from the study.

Reversibility of dermal lesions should be considered in evaluating irritant responses. When responses such as alopecia (limited area), hyperkeratosis, hyperplasia and scaling, persist to the end of the 14-day observation period, the test substance should be considered an irritant.

3.   REPORTING

3.1.   TEST REPORT

The test report must include the following information:

Rationale for in vivo testing: weight-of-evidence analysis of pre-existing test data, including results from sequential testing strategy:

 description of relevant data available from prior testing,

 data derived at each stage of testing strategy,

 description of in vitro tests performed, including details of procedures, results obtained with test/reference substances,

 weight-of-the-evidence analysis for performing in vivo study.

Test substance:

 identification data (e.g. CAS number, source, purity, known impurities, lot number),

 physical nature and physicochemical properties (e.g. pH, volatility, solubility, stability),

 if mixture, composition and relative percentages of components.

Vehicle:

 identification, concentration (where appropriate), volume used,

 justification for choice of vehicle.

Test animals:

 species/strain used, rationale for using animals other than albino rabbit,

 number of animals of each sex,

 individual animal weights at start and conclusion of test,

 age at start of study,

 source of animals, housing conditions, diet, etc.

Test conditions:

 technique of patch site preparation,

 details of patch materials used and patching technique,

 details of test substance preparation, application, and removal.

Results:

 tabulation of irritation/corrosion response scores for each animal at all time points measured,

 descriptions of all lesions observed,

 narrative description of nature and degree of irritation or corrosion observed, and any histopathological findings,

 description of other adverse local (e.g. defatting of skin) and systemic effects in addition to dermal irritation or corrosion.

 Discussion of results

4.   REFERENCES

(1) Barratt, M.D., Castell, J.V., Chamberlain, M., Combes, R.D., Dearden, J.C., Fentem, J.H., Gerner, I., Giuliani, A., Gray, T.J.B., Livingston, D.J., Provan, W.M., Rutten, F.A.J.J.L., Verhaar, H.J.M., Zbinden, P. (1995) The Integrated Use of Alternative Approaches for Predicting Toxic Hazard. ECVAM Workshop Report 8. ATLA 23, p. 410-429.

(2) Young, J.R., How, M.J., Walker, A.P., Worth W.M.H. (1988) Classification as Corrosive or Irritant to Skin of Preparations Containing Acidic or Alkaline Substance Without Testing on Animals. Toxicollogy In Vitro, 2, p. 19-26.

(3) Worth, A.P., Fentem, J.H., Balls, M., Botham, P.A., Curren, R.D., Earl, L.K., Esdaile, D.J., Liebsch, M. (1998) Evaluation of the proposed OECD Testing Strategy for skin corrosion. ATLA 26, p. 709-720.

(4) ECETOC (1990) Monograph No 15, ‘Skin Irritation’, European Chemical Industry, Ecology and Toxicology Centre, Brussels.

(5) Fentem, J.H., Archer, G.E.B., Balls, M., Botham, P.A., Curren, R.D., Earl, L.K., Edsail, D.J., Holzhutter, H.G. and Liebsch, M. (1998) The ECVAM international validation study on in vitro tests for skin corrosivity. 2. Results and evaluation by the Management Team. Toxicology In Vitro 12, p. 483-524.

(5a) Testing Method B.40 Skin Corrosion.

(6) OECD (1996) OECD Test Guidelines Programme: Final Report of the OECD Workshop on Harmonisation of Validation and Acceptance Criteria for Alternative Toxicological Test Methods. Held in Solna, Sweden, 22-24 January 1996 (http://www.oecd1.org/ehs/test/background.htm).

(7) OECD (1998) Harmonised Integrated Hazard Classification System for Human Health and Environmental Effects of Chemical Substances, as endorsed by the 28th Joint Meeting of the Chemicals Committee and the Working Party on Chemicals, November 1998 (http://www.oecd1.org/ehs/Class/HCL6.htm).

(8) OECD (2000). Guidance Document on the Recognition, Assessment and Use of Clinical Signs as Humane Endpoints for Experimental Animals Used in Safety Evaluation. OECD Environmental Health and Safety Publications. Series on Testing and Assessment No 19 (http://www.oecd1.org/ehs/test/monos.htm).

(9) EPA (1990). Atlas of Dermal Lesions, (20T-2004). United States Environmental Protection Agency, Office of Pesticides and Toxic Substances, Washington, DC, August 1990.

[Available from OECD Secretariat upon request].

Table I

GRADING OF SKIN REACTIONS



Erythema and Eschar formation

No erythema …

0

Very slight erythema (barely perceptible) …

1

Well defined erythema …

2

Moderate to severe erythema …

3

Severe erythema (beef redness) to eschar formation preventing grading of erythema …

4

Maximum possible: 4



Oedema formation

No oedema …

0

Very slight oedema (barely perceptible) …

1

Slight oedema (edges of area well defined by definite raising) …

2

Moderate oedema (raised approximately 1 mm) …

3

Severe oedema (raised more than 1 mm and extending beyond area of exposure) …

4

Maximum possible: 4

Histopathological examination may be carried out to clarify equivocal responses.

Appendix

A Sequential Testing Strategy for Dermal Irritation and Corrosion

GENERAL CONSIDERATIONS

In the interest of sound science and animal welfare, it is important to avoid the unnecessary use of animals and to minimise any testing that is likely to produce severe responses in animals. All information on a substance relevant to its potential skin corrosivity/irritancy should be evaluated prior to considering in vivo testing. Sufficient evidence may already exist to classify a test substance as to its dermal corrosion or irritation potential without the need to conduct testing in laboratory animals. Therefore, utilising a weight-of-the-evidence analysis and a sequential testing strategy, will minimise the need for in vivo testing, especially if the substance is likely to produce severe reactions.

It is recommended that a weight-of-the-evidence analysis be used to evaluate existing information regarding the skin irritation and corrosion of substances to determine whether additional studies, other than in vivo dermal studies, should be performed to help characterise such potential. Where further studies are needed, it is recommended that the sequential testing strategy be utilised to develop the relevant experimental data. For substances which have no testing history, the sequential testing strategy should be utilised to develop the data set needed to evaluate its dermal corrosion/irritation potential. The testing strategy described in this Appendix was developed at an OECD workshop (1) and was later affirmed and expanded in the Harmonised Integrated Hazard Classification System for Human Health and Environmental Effects of Chemical Substances, as endorsed by the 28th Joint Meeting of the Chemicals Committee and the Working Party on Chemicals, in November 1998 (2).

Although this sequential testing strategy is not an integral part of testing method B.4, it expresses the recommended approach for the determination of skin irritation/corrosion characteristics. This approach represents both best practice and an ethical benchmark for in vivo testing for skin irritation/corrosion. The testing method provides guidance for the conduct of the in vivo test and summarises the factors that should be addressed before initiating such a test. The strategy provides an approach for the evaluation of existing data on the skin irritation/corrosion properties of test substances and a tiered approach for the generation of relevant data on substances for which additional studies are needed, or for which no studies have been performed. It also recommends the performance of validated and accepted in vitro or ex vivo tests for skin corrosion/irritation under specific circumstances.

DESCRIPTION OF THE EVALUATION AND TESTING STRATEGY

Prior to undertaking tests as part of the sequential testing strategy (Figure), all available information should be evaluated to determine the need for in vivo skin testing. Although significant information might be gained from the evaluation of single parameters (e.g. extreme pH), the totality of existing information should be considered. All relevant data on the effects of the substance in question, or its analogues, should be evaluated in making a weight-of-the-evidence decision, and a rationale for the decision should be presented. Primary emphasis should be placed upon existing human and animal data on the substance, followed by the outcome of in vitro or ex vivo testing. In vivo studies of corrosive substances should be avoided whenever possible. The factors considered in the testing strategy include:

Evaluation of existing human and animal data (Step 1). Existing human data, e.g. clinical or occupational studies and case reports, and/or animal test data, e.g. from single or repeated dermal exposure toxicity studies, should be considered first, because they provide information directly related to effects on the skin. Substances with known irritancy or corrosivity, and those with clear evidence of non-corrosivity or non-irritancy, need not be tested in in vivo studies.

Analysis of structure activity relationships (SAR) (Step 2). The results of testing of structurally related substances should be considered, if available. When sufficient human and/or animal data are available on structurally related substances or mixtures of such substances to indicate their skin corrosion/irritancy potential, it can be presumed that the test substance being evaluated will produce the same responses. In those cases, the test substance may not need to be tested. Negative data from studies of structurally related substances or mixtures of such substances do not constitute sufficient evidence of non-corrosivity/non-irritancy of a substance under the sequential testing strategy. Validated and accepted SAR approaches should be used to identify both dermal corrosion and irritation potential.

Physicochemical properties and chemical reactivity (Step 3). Substances exhibiting pH extremes such as ≤ 2,0 and ≥ 11,5 may have strong local effects. If extreme pH is the basis for identifying a substance as corrosive to skin, then its acid/alkali reserve (or buffering capacity) may also be taken into consideration (3)(4). If the buffering capacity suggests that a substance may not be corrosive to the skin, then further testing should be undertaken to confirm this, preferably by the use of a validated and accepted in vitro or ex vivo test (see steps 5 and 6).

Dermal toxicity (Step 4). If a chemical has proven to be very toxic by the dermal route, an in vivo dermal irritation/corrosion study may not be practicable because the amount of test substance normally applied could exceed the very toxic dose and, consequently result in the death or severe suffering of the animals. In addition, when dermal toxicity studies utilising albino rabbits have already been performed up to the limit dose level of 2 000 mg/kg body weight or higher, and no dermal irritation or corrosion has been seen, additional testing for skin irritation/corrosion may not be needed. A number of considerations should be borne in mind when evaluating acute dermal toxicity in previously performed studies. For example, reported information on dermal lesions may be incomplete. Testing and observations may have been made on a species other than the rabbit, and species may differ widely in sensitivity of their responses. Also the form of test substance applied to animals may not have been suitable for assessment of skin irritation/corrosion (e.g., dilution of substances for testing dermal toxicity (5). However, in those cases in which well-designed and conducted dermal toxicity studies have been performed in rabbits, negative findings may be considered sufficient evidence that the substance is not corrosive or irritating.

Results from in vitro or ex vivo tests (Steps 5 and 6). Substances that have demonstrated corrosive or severe irritant properties in a validated and accepted in vitro or ex vivo test (6)(7) designed for the assessment of these specific effects, need not be tested in animals. It can be presumed that such substances will produce similar severe effects in vivo.

In vivo test in rabbits (Steps 7 and 8). Should a weight-of the-evidence decision be made to conduct in vivo testing, it should begin with an initial test using one animal. If the results of this test indicate the substance to be corrosive to the skin, further testing should not be performed. If a corrosive effect is not observed in the initial test, the irritant or negative response should be confirmed using up to two additional animals for an exposure period of four hours. If an irritant effect is observed in the initial test, the confirmatory test may be conducted in a sequential manner, or by exposing the two additional animals simultaneously.

REFERENCES

(1) OECD, (1996) Test Guidelines Programme: Final Report on the OECD Workshop on Harmonisation of Validation and Acceptance Criteria for Alternative Toxicological Test Methods. Held on Solna, Sweden, 22-24 January 1996 (http://www1.oecd.org/ehs/test/background.htm).

(2) OECD, (1998) Harmonised Integrated Hazard Classification System for Human Health and Environmental Effects of Chemical Substances, as endorsed by the 28th Joint Meeting of the Chemicals Committee and the Working Party on Chemicals, November 1998 (http://www1.oecd.org/ehs/Class/HCL6.htm).

(3) Worth, A.P., Fentem J.H., Balls M., Botham P.A., Curren R.D., Earl L.K., Esdaile D.J., Liebsch M., (1998). An Evaluation of the Proposed OECD Testing Strategy for Skin Corrosion. ATLA 26, p. 709-720.

(4) Young, J.R., How, M.J., Walker, A.P., Worth, W.M.H., (1988). Classification as Corrosive or Irritant to Skin of Preparations Containing Acidic or Alkaline Substances, Without Testing on Animals. Toxicology In Vitro, 2(1), p. 19-26.

(5) Patil, S.M., Patrick, E., Maibach, H.I. (1996) Animal, Human, and In Vitro Test Methods for Predicting Skin Irritation, in: Francis N. Marzulli and Howard I. Maibach (editors): Dermatotoxicology. Fifth Edition ISBN 1-56032-356-6, Chapter 31, p. 411-436.

(6) Testing Method B.40.

(7) Fentem, J.H., Archer, G.E.B., Balls, M., Botham, P.A., Curren, R.D., Earl, L.K., Esdaile, D.J., Holzhutter, H.G. and Liebsch, M. (1998) The ECVAM international validation study on in vitro tests for skin corrosivity. 2. Results and evaluation by the Management Team. Toxicology In Vitro 12, p. 483-524.

Figure

TESTING AND EVALUATION STRATEGY FOR DERMAL IRRITATION/CORROSION

ActivityFindingConclusion1CorrosiveApical endpoint; considered corrosive. No testing is needed.IrritatingApical endpoint; considered to be an irritant. No testing is needed.Not corrosive/not irritatingApical endpoint; considered not corrosive or irritating. No testing required.Existing human and/or animal data showing effects on skin or mucous membranes↓No information available, or available information is not conclusive↓2Perform SAR evaluation for skin corrosion/irritationPredict severe damage to skinConsidered corrosive. No testing is needed.Predict irritation to skinConsidered an irritant. No testing is needed.↓No predictions can be made, or predictions are not conclusive or negative↓3Measure pH (consider buffering capacity, if relevant)pH ≤ 2 or ≥ 11.5 (with high buffering capacity, if relevant)Assume corrosivity. No testing is needed.↓2 < pH < 11.5, or pH ≤ 2.0 or ≥ 11.5 with low/no buffering capacity, if relevant↓4Evaluate systemic toxicity data via dermal route (1)Very toxicNo further testing is needed.Not corrosive or irritating when tested to limit dose of 2000 mg/kg body weight or higher, using rabbitsAssume not corrosive or irritating. No further testing is needed.↓Such information is not available or is non-conclusive↓5Perform validated and accepted in vitro or ex vivo test for skin corrosionCorrosive responseAssume corrosivity in vivo. No further testing is needed.↓Substance is not corrosive↓6Perform validated and accepted in vitro or ex vivo test for skin irritationIrritant responseAssume irritancy in vivo. No further testing is needed.↓Validated in vitro or ex vivo testing methods for skin irritation are not yet available or substance is not an irritant↓7Perform initial in vivo rabbit test using one animalSevere damage to skinConsidered corrosive. No further testing is needed.↓No severe damage↓8Perform confirmatory test using one or two additional animalsCorrosive or irritatingConsidered corrosive or irritating. No further testing is neededNot corrosive or irritatingConsidered not corrosive or irritating. No further testing needed(1) can be considered before Steps 2 and 3.

B.5.   ACUTE TOXICITY: EYE IRRITATION/CORROSION

1.   METHOD

This method is equivalent to the OECD TG 405 (2002)

1.1.   INTRODUCTION

In the preparation of this updated method special attention was given to possible improvements through the evaluation of all existing information on the test substance in order to avoid unnecessary testing in laboratory animals and thereby address animal welfare concerns. This method includes the recommendation that prior to undertaking the described in vivo test for acute eye irritation/corrosion, a weight-of-the-evidence analysis be performed (1) on the existing relevant data. Where insufficient data are available, it is recommended that they be developed through application of sequential testing (2)(3). The testing strategy includes the performance of validated and accepted in vitro tests and is provided as an Appendix to the testing method. In addition, the use of an in vivo dermal irritation/corrosion test to predict eye corrosion prior to consideration of an in vivo eye test is recommended.

In the interest of both sound science and animal welfare, in vivo testing should not be considered until all available data relevant to the potential eye corrosivity/irritation of the substance has been evaluated in a weight-of-the-evidence analysis. Such data will include evidence from existing studies in humans and/or laboratory animals, evidence of corrosivity/irritation of one or more structurally related substances or mixtures of such substances, data demonstrating high acidity or alkalinity of the substance (4)(5), and results from validated and accepted in vitro or ex vivo tests for skin corrosion and irritation (6)(6a). The studies may have been conducted prior to, or as a result of, a weight-of-the-evidence analysis.

For certain substances, such an analysis may indicate the need for in vivo studies of the ocular corrosion/irritation potential of the substance. In all such cases, before considering the use of the in vivo eye test, preferably a study of the in vivo dermal effects of the substance should be conducted first and evaluated in accordance with testing method B.4 (7). The application of a weight-of-the-evidence analysis and the sequential testing strategy should decrease the need for in vivo testing for eye corrosivity/irritation of substances for which sufficient evidence already exists from other studies. If a determination of eye corrosion or irritation potential cannot be made using the sequential testing strategy, even after the performance of an in vivo study of dermal corrosion and irritation, an in vivo eye corrosion/irritation test may be performed.

A preferred sequential testing strategy, which includes the performance of validated in vitro or ex vivo tests for corrosion/irritation, is included in the Appendix to this testing method. The strategy was developed at, and unanimously recommended by the participants of, an OECD workshop (8), and has been adopted as the recommended testing strategy in the Globally Harmonised System for the Classification of Chemical Substances (GHS) (9). It is recommended that this testing strategy be followed prior to undertaking in vivo testing. For new substances it is the recommended stepwise testing approach for developing scientifically sound data on the corrosivity/irritation of the substance. For existing substances with insufficient data on skin and eye corrosion/irritation, the strategy should be used to fill missing data gaps. The use of a different testing strategy or procedure, or the decision not to use a stepwise testing approach, should be justified.

1.2.   DEFINITIONS

Eye irritation: is the production of changes in the eye following the application of a test substance to the anterior surface of the eye, which are fully reversible within 21 days of application.

Eye corrosion: is the production of tissue damage in the eye, or serious physical decay of vision, following application of a test substance to the anterior surface of the eye, which is not fully reversible within 21 days of application.

1.3.   PRINCIPLE OF THE TEST METHOD

The substance to be tested is applied in a single dose to one of the eyes of the experimental animal; the untreated eye serves as the control. The degree of eye irritation/corrosion is evaluated by scoring lesions of conjunctiva, cornea, and iris, at specific intervals. Other effects in the eye and adverse systemic effects are also described to provide a complete evaluation of the effects. The duration of the study should be sufficient to evaluate the reversibility or irreversibility of the effects.

Animals showing continuing signs of severe distress and/or pain at any stage of the test should be humanely killed, and the substance assessed accordingly. Criteria for making the decision to humanely kill moribund and severely suffering animals can be found in reference (10).

1.4.   DESCRIPTION OF THE TEST METHOD

1.4.1.   Preparation for the in vivo test

1.4.1.1.   Selection of species

The albino rabbit is the preferable laboratory animal, and healthy young adult animals are used. A rationale for using other strains or species should be provided.

1.4.1.2.   Preparation of animals

Both eyes of each experimental animal provisionally selected for testing should be examined within 24 hours before testing starts. Animals showing eye irritation, ocular defects, or pre-existing corneal injury should not be used.

1.4.1.3.   Housing and feeding conditions

Animals should be individually housed. The temperature of the experimental animal room should be 20 oC (± 3 oC) for rabbits. Although the relative humidity should be at least 30 % and preferably not exceed 70 %, other than during room cleaning, the aim should be 50-60 %. Lighting should be artificial, the sequence being 12 hours light, 12 hours dark. For feeding, conventional laboratory diets may be used with an unrestricted supply of drinking water.

1.4.2.   Test procedure

1.4.2.1.   Application of the test substance

The test substance should be placed in the conjunctival sac of one eye of each animal after gently pulling the lower lid away from the eyeball. The lids are then gently held together for about one second in order to prevent loss of the material. The other eye, which remains untreated, serves as a control.

1.4.2.2.   Irrigation

The eyes of the test animals should not be washed for at least 24 hours following instillation of the test substance, except for solids (see Section 1.4.2.3.2), and in case of immediate corrosive or irritating effects. At 24 hours a washout may be used if considered appropriate.

Use of a satellite group of animals to investigate the influence of washing is not recommended unless it is scientifically justified. If a satellite group is needed, two rabbits should be used. Conditions of washing should be carefully documented, e.g. time of washing; composition and temperature of wash solution; duration, volume, and velocity of application.

1.4.2.3.   Dose level

1.4.2.3.1.    Testing of liquids

For testing liquids, a dose of 0,1 ml is used. Pump sprays should not be used for instilling the substance directly into the eye. The liquid spray should be expelled and collected in a container prior to instilling 0,1 ml into the eye.

1.4.2.3.2.    Testing of solids

When testing solids, pastes, and particulate substances, the amount used should have a volume of 0,1 ml or a weight of not more than 100 mg. The test material should be ground to a fine dust. The volume of solid material should be measured after gently compacting it, e.g. by tapping the measuring container. If the solid test substance has not been removed from the eye of the test animal by physiological mechanisms at the first observation time point of one hour after treatment, the eye may be rinsed with saline or distilled water.

1.4.2.3.3.    Testing of aerosols

It is recommended that all pump sprays and aerosols be collected prior to instillation into the eye. The one exception is for substances in pressurised aerosol containers, which cannot be collected due to vaporisation. In such cases, the eye should be held open, and the test substance administered to the eye in a simple burst of about one second, from a distance of 10 cm directly in front of the eye. This distance may vary depending on the pressure of the spray and its contents. Care should be taken not to damage the eye from the pressure of the spray. In appropriate cases, there may be a need to evaluate the potential for ‘mechanical’ damage to the eye from the force of the spray.

An estimate of the dose from an aerosol can be made by simulating the test as follows: the substance is sprayed on to weighing paper through an opening the size of a rabbit eye placed directly before the paper. The weight increase of the paper is used to approximate the amount sprayed into the eye. For volatile substances, the dose may be estimated by weighing a receiving container before and after removal of the test material.

1.4.2.4.   Initial test (in vivo eye irritation/corrosion test using one animal)

As articulated in the sequential testing strategy (see Appendix 1), it is strongly recommended that the in vivo test be performed initially using one animal.

If the results of this test indicate the substance to be corrosive or a severe irritant to the eye using the procedure described, further testing for ocular irritancy should not be performed.

1.4.2.5.   Local anaesthetics

Local anaesthetics may be used on a case-by-case basis. If the weight-of-the-evidence analysis indicates that the substance has the potential to cause pain, or initial testing shows that a painful reaction will occur, a local anaesthetic may be used prior to instillation of the test substance. The type, concentration, and dose of the local anaesthetic should be carefully selected to ensure that differences in reaction to the test substance will not result from its use. The control eye should be similarly anaesthetised.

1.4.2.6.   Confirmatory test (in vivo eye irritation test with additional animals)

If a corrosive effect is not observed in the initial test, the irritant or negative response should be confirmed using up to two additional animals. If a severe irritant effect is observed in the initial test indicating a possible strong (irreversible) effect in the confirmatory testing, it is recommended that the confirmatory test be conducted in a sequential manner in one animal at a time, rather than exposing the two additional animals simultaneously. If the second animal reveals corrosive or severe irritant effects, the test is not continued. Additional animals may be needed to confirm weak or moderate irritant responses.

1.4.2.7.   Observation period

The duration of the observation period should be sufficient to evaluate fully the magnitude and reversibility of the effects observed. However, the experiment should be terminated at any time that the animal shows continuing signs of severe pain or distress (9). To determine reversibility of effects, the animals should be observed normally for 21 days post administration of the test substance. If reversibility is seen before 21 days, the experiment should be terminated at that time.

1.4.2.7.1.    Clinical observations and grading of eye reactions

The eyes should be examined at one, 24, 48, and 72 hours after test substance application. Animals should be kept on test no longer than necessary once definitive information has been obtained. Animals showing continuing severe pain or distress should be humanely killed without delay, and the substance assessed accordingly. Animals with the following eye lesions post-instillation should be humanely killed: corneal perforation or significant corneal ulceration including staphyloma; blood in the anterior chamber of the eye; grade 4 corneal opacity which persists for 48 hours; absence of a light reflex (iridial response grade 2) which persists for 72 hours; ulceration of the conjunctival membrane; necrosis of the conjuctivae or nictitating membrane; or sloughing. This is because such lesions generally are not reversible

Animals that do not develop ocular lesions may be terminated not earlier than three days post instillation. Animals with mild to moderate lesions should be observed until the lesions clear, or for 21 days, at which time the study is terminated. Observations should be performed at seven, 14, and 21 days in order to determine the status of the lesions, and their reversibility or irreversibility.

The grades of ocular reaction (conjunctivae, cornea and iris) should be recorded at each examination (Table I). Any other lesions in the eye (e.g. pannus, staining) or adverse systemic effects should also be reported.

Examination of reactions can be facilitated by use of a binocular loupe, hand slit-lamp, biomicroscope, or other suitable device. After recording the observations at 24 hours, the eyes may be further examined with the aid of fluorescein.

The grading of ocular responses is necessarily subjective. To promote harmonisation of grading of ocular response and to assist testing laboratories and those involved in making and interpreting the observations, the personnel performing the observations need to be adequately trained in the scoring system used.

2.   DATA

2.2.   EVALUATION OF RESULTS

The ocular irritation scores should be evaluated in conjunction with the nature and severity of lesions, and their reversibility or lack of reversibility. The individual scores do not represent an absolute standard for the irritant properties of a material, as other effects of the test material are also evaluated. Instead, individual scores should be viewed as reference values and are only meaningful when supported by a full description and evaluation of all observations.

3.   REPORTING

3.1.   TEST REPORT

The test report must include the following information:

Rationale for in vivo testing: weight-of-the-evidence analysis of pre-existing test data, including results from sequential testing strategy

 description of relevant data available from prior testing,

 data derived in each step of testing strategy,

 description of in vitro tests performed, including details of procedures, results obtained with test/reference substances,

 description of in vivo dermal irritation/corrosion study performed, including results obtained,

 weight-of-the-evidence analysis for performing in vivo study.

Test substance:

 identification data (e.g. CAS number, source, purity, known impurities, lot number),

 physical nature and physicochemical properties (e.g. pH, volatility, solubility, stability, reactivity with water),

 in case of a mixture, composition and relative percentages of components,

 if local anaesthetic is used, identification, purity, type, dose, and potential interaction with test substance.

Vehicle:

 identification, concentration (where appropriate), volume used,

 justification for choice of vehicle.

Test animals:

 species/strain used, rationale for using animals other than albino rabbit,

 age of each animal at start of study,

 number of animals of each sex in test and control groups (if required),

 individual animal weights at start and conclusion of test,

 source, housing conditions, diet, etc.

Results:

 description of method used to score irritation at each observation time (e.g. hand slitlamp, biomicroscope, fluorescein),

 tabulation of irritant/corrosive response data for each animal at each observation time up to removal of each animal from the test,

 narrative description of the degree and nature of irritation or corrosion observed,

 description of any other lesions observed in the eye (e.g. vascularisation, pannus formation, adhesions, staining),

 description of non-ocular local and systemic adverse effects, and histopathological findings, if any.

Discussion of results.

3.2.   INTERPRETATION OF THE RESULTS

Extrapolation of the results of eye irritation studies in laboratory animals to humans is valid only to a limited degree. In many cases the albino rabbit is more sensitive than humans to ocular irritants or corrosives.

Care should be taken in the interpretation of data to exclude irritation resulting from secondary infection.

4.   REFERENCES

(1) Barratt, M.D., Castell, J.V., Chamberlain, M., Combes, R.D., Dearden, J.C., Fentem, J.H., Gerner, I., Giuliani, A., Gray, T.J.B., Livingston, D.J., Provan, W.M., Rutten, F.A.J.J.L., Verhaar, H.J.M., Zbinden, P. (1995) The Integrated Use of Alternative Approaches for Predicting Toxic Hazard. ECVAM Workshop Report 8. ATLA 23, p. 410-429.

(2) de Silva, O., Cottin, M., Dami, N., Roguet, R., Catroux, P., Toufic, A., Sicard, C., Dossou, K.G., Gerner, I., Schlede, E., Spielmann, H., Gupta, K.C., Hill, R.N., (1997) Evaluation of Eye Irritation Potential: Statistical Analysis and Tier Testing Strategies. Food Chem. Toxicol 35, p. 159-164.

(3) Worth A.P. and Fentem J.H., (1999) A general approach for evaluating stepwise testing strategies ATLA 27, p. 161-177

(4) Young, J.R., How, M.J., Walker, A.P., Worth W.M.H., (1988) Classification as Corrosive or Irritant to Skin of Preparations Containing Acidic or Alkaline Substance Without Testing on Animals. Toxicollogy In Vitro, 2, p. 19-26.

(5) Neun, D.J. (1993) Effects of Alkalinity on the Eye Irritation Potential of Solutions Prepared at a Single pH. J. Toxicol. Cut. Ocular Toxicol. 12, p. 227-231.

(6) Fentem, J.H., Archer, G.E.B., Balls, M., Botham, P.A., Curren, R.D., Earl, L.K., Edsaile, D.J., Holzhutter, H.G. and Liebsch, M. (1998) The ECVAM international validation study on in vitro tests for skin corrosivity. 2. Results and evaluation by the Management Team. Toxicology In Vitro 12, p. 483-524.

(6a) Testing Method B.40 Skin Corrosion.

(7) Testing method B.4. Acute toxicity: dermal irritation/corrosion.

(8) OECD, (1996) OECD Test Guidelines Programme: Final Report of the OECD Workshop on Harmonisation of Validation and Acceptance Criteria for Alternative Toxicological Test Methods. Held in Solna, Sweden, 22-24 January 1996 (http://www.oecd.org/ehs/test/background.htm).

(9) OECD, (1998) Harmonised Integrated Hazard Classification System for Human Health and Environmental Effects of Chemical Substances, as endorsed by the 28th Joint Meeting of the Chemicals Committee and the Working Party on Chemicals, November 1998 (http://www.oecd.org/ehs/Class/HCL6.htm).

(10) OECD, (2000) Guidance Document on the Recognition, Assessment and Use of Clinical Signs as Humane Endpoints for Experimental Animals Used in Safety Evaluation. OECD Environmental Health and Safety Publications. Series on Testing and Assessment No 19 (http://www.oecd.org/ehs/test/monos.htm).

Table I

GRADING OF OCULAR LESIONS

Cornea

Opacity: degree of density (readings should be taken from most dense area) ( 15 )



No ulceration or opacity …

0

Scattered or diffuse areas of opacity (other than slight dulling of normal lustre); details of iris clearly visible …

1

Easily discernible translucent area; details of iris slightly obscured …

2

Nacrous area; no details of iris visible; size of pupil barely discernible …

3

Opaque cornea; iris not discernible through the opacity …

4

Maximum possible: 4

NOTES

Iris



Normal …

0

Markedly deepened rugae, congestion, swelling, moderate circumcorneal hyperaemia; or injection; iris reactive to light (a sluggish reaction is considered to be an effect) …

1

Hemorrhage, gross destruction, or no reaction to light …

2

Maximum possible: 2

Conjunctivae

Redness (refers to palpebral and bulbar conjunctivae; excluding cornea and iris)



Normal …

0

Some blood vessels hyperaemic (injected) …

1

Diffuse, crimson colour; individual vessels not easily discernible …

2

Diffuse beefy red …

3

Maximum possible: 3

Chemosis

Swelling (refers to lids and/or nictating membranes)



Normal …

0

Some swelling above normal …

1

Obvious swelling, with partial eversion of lids …

2

Swelling, with lids about half closed …

3

Swelling, with lids more than half closed …

4

Maximum possible: 4

Appendix

A Sequential Testing Strategy for Eye Irritation and Corrosion

GENERAL CONSIDERATIONS

In the interests of sound science and animal welfare, it is important to avoid the unnecessary use of animals, and to minimise testing that is likely to produce severe responses in animals. All information on a substance relevant to its potential ocular irritation/corrosivity should be evaluated prior to considering in vivo testing. Sufficient evidence may already exist to classify a test substance as to its eye irritation or corrosion potential without the need to conduct testing in laboratory animals. Therefore, utilising a weight-of-the-evidence analysis and sequential testing strategy will minimise the need for in vivo testing, especially if the substance is likely to produce severe reactions.

It is recommended that a weight-of-the-evidence analysis be used to evaluate existing information pertaining to eye irritation and corrosion of substances and to determine whether additional studies, other than in vivo eye studies, should be performed to help characterise such potential. Where further studies are needed, it is recommended that the sequential testing strategy be utilised to develop the relevant experimental data. For substances which have no testing history, the sequential testing strategy should be utilised to develop the data needed to evaluate its eye corrosion/irritation. The testing strategy described in this Appendix was developed at an OECD workshop (1). It was subsequently affirmed and expanded in the Harmonised Integrated Hazard Classification System for Human Health and Environmental Effects of Chemical Substances, as endorsed by the 28th Joint Meeting of the Chemicals Committee and the Working Party on Chemicals, in November 1998 (2).

Although this testing strategy is not an integrated part of testing method B.5, it expresses the recommended approach for the determination of eye irritation/corrosion properties. This approach represents both best practice and an ethical benchmark for in vivo testing for eye irritation/corrosion. The testing method provides guidance for the conduct of the in vivo test and summarises the factors that should be addressed before considering such a test. The sequential testing strategy provides a weight-of-the-evidence approach for the evaluation of existing data on the eye irritation/corrosion properties of substances and a tiered approach for the generation of relevant data on substances for which additional studies are needed or for which no studies have been performed. The strategy includes the performance first of validated and accepted in vitro or ex vivo tests and then of testing method B.4 skin irritation/corrosion studies under specific circumstances (3)(4).

DESCRIPTION OF THE STEPWISE TESTING STRATEGY

Prior to undertaking tests as part of the sequential testing strategy (Figure), all available information should be evaluated to determine the need for in vivo eye testing. Although significant information might be gained from the evaluation of single parameters (e.g., extreme pH), the totality of existing information should be assessed. All relevant data on the effects of the substance in question, and its structural analogues, should be evaluated in making a weight-of-the-evidence decision, and a rationale for the decision should be presented. Primary emphasis should be placed upon existing human and animal data on the substance, followed by the outcome of in vitro or ex vivo testing. In vivo studies of corrosive substances should be avoided whenever possible. The factors considered in the testing strategy include:

Evaluation of existing human and animal data (Step 1). Existing human data, e.g. clinical and occupational studies, and case reports, and/or animal test data from ocular studies should be considered first, because they provide information directly related to effects on the eyes. Thereafter, available data from human and/or animal studies investigating dermal corrosion/irritation should be evaluated. Substances with known corrosivity or severe irritancy to the eye should not be instilled into the eyes of animals, nor should substances showing corrosive or irritant effects to the skin; such substances should be considered to be corrosive and/or irritating to the eyes as well. Substances with sufficient evidence of non-corrosivity and non-irritancy from previously performed ocular studies should also not be tested in in vivo eye studies.

Analysis of structure activity relationships (SAR) (Step 2). The results of testing of structurally related chemicals should be considered, if available. When sufficient human and/or animal data are available on structurally related substances or mixtures of such substances to indicate their eye corrrosion/irritancy potential, it can be presumed that the test substance will produce the same responses. In those cases, the substance may not need to be tested. Negative data from studies of structurally related substances or mixtures of such substances do not constitute sufficient evidence of non-corrosivity/non-irritancy of a substance under the sequential testing strategy. Validated and accepted SAR approaches should be used to identify the corrosion and irritation potential for both dermal and ocular effects.

Physicochemical properties and chemical reactivity (Step 3). Substances exhibiting pH extremes such as ≤ 2,0 or ≥ 11,5 may have strong local effects. If extreme pH is the basis for identifying a substance as corrosive or irritant to the eye, then its acid/alkaline reserve (buffering capacity) may also be taken into consideration (5)(6). If the buffering capacity suggests that a substance may not be corrosive to the eye, then further testing should be undertaken to confirm this, preferably by the use of a validated and accepted in vitro or ex vivo test (see Section step 5 and 6).

Consideration of other existing information (Step 4). All available information on systemic toxicity via the dermal route should be evaluated at this stage. The acute dermal toxicity of the test substance should also be considered. If the test substance has been shown to be very toxic by the dermal route, it may not need to be tested in the eye. Although there is not necessarily a relationship between acute dermal toxicity and eye irritation/corrosion, it can be assumed that if an agent is very toxic via the dermal route, it will also exhibit high toxicity when instilled into the eye. Such data may also be considered between Steps 2 and 3.

Results from in vitro or ex vivo tests (Steps 5 and 6). Substances that have demonstrated corrosive or severe irritant properties in an in vitro or ex vivo test (7)(8) that has been validated and accepted for the assessment specifically of eye or skin corrosivity/irritation, need not be tested in animals. It can be presumed that such substances will produce similar severe effects in vivo. If validated and accepted in vitro/ex vivo tests are not available, one should bypass Steps 5 and 6 and proceed directly to Step 7.

Assessment of in vivo dermal irritancy or corrosivity of the substance (Step 7). When insufficient evidence exists with which to perform a conclusive weight-of-the-evidence analysis of the potential eye irritation/corrosivity of a substance based upon data from the studies listed above, the in vivo skin irritation/corrosion potential should be evaluated first, using testing method B.4 (4) and its accompanying Appendix (9). If the substance is shown to produce corrosion or severe skin irritation, it should be considered to be a corrosive eye irritant unless other information supports an alternative conclusion. Thus, an in vivo eye test would not need to be performed. If the substance is not corrosive or severely irritating to the skin, an in vivo eye test should be performed.

In vivo test in rabbits (Steps 8 and 9): in vivo ocular testing should begin with an initial test using one animal. If the results of this test indicate the substance to be a severe irritant or corrosive to the eyes, further testing should not be performed. If that test does not reveal any corrosive or severe irritant effects, a confirmatory test is conducted with two additional animals.

REFERENCES

(1) OECD, (1996) OECD Test Guidelines Programme: Final Report of the OECD Workshop on Harmonisation of Validation and Acceptance Criteria for Alternative Toxicological Test Methods. Held in Solna, Sweden, 22-24 January 1996 (http://www.oecd.org/ehs/test/background.htm).

(2) OECD, (1998) Harmonised Integrated Hazard Classification System for Human Health and Environmental Effects of Chemical Substances, as endorsed by the 28th Joint Meeting of the Chemicals Committee and the Working Party on Chemicals, November 1998 (http://www.oecd.org/ehs/Class/HCL6.htm).

(3) Worth, A.P. and Fentem J.H., (1999). A General Approach for Evaluating Stepwise Testing Strategies. ATLA 27, p. 161-177.

(4) Testing method B.4. Acute Toxicity: dermal irritation/corrosion.

(5) Young, J.R., How, M.J., Walker, A.P., Worth W.M.H., (1988) Classification as Corrosive or Irritant to Skin of Preparations Containing Acidic or Alkaline Substance Without Testing on Animals. Toxicolohy In Vitro, 27, p. 19-26.

(6) Neun, D.J., (1993) Effects of Alkalinity on the Eye Irritation Potential of Solutions Prepared at a Single pH. J. Toxicol. Cut. Ocular Toxicol. 12, p. 227-231.

(7) Fentem, J.H., Archer, G.E.B., Balls, M., Botham, P.A., Curren, R.D., Earl, L.K., Edsail, D.J., Holzhutter, H.G. and Liebsch, M., (1998) The ECVAM international validation study on in vitro tests for skin corrosivity. 2. Results and evaluation by the Management Team. Toxicology In Vitro 12, p. 483-524.

(8) Testing Method B.40 Skin Corrosion.

(9) Appendix to Testing method B.4: A Sequential Testing Strategy for Skin Irritation and Corrosion.

Figure

TESTING AND EVALUATION STRATEGY FOR EYE IRRITATION/CORROSION

ActivityFindingConclusion1Existing human and/or animal data showing effects on eyesSevere damage to eyesApical endpoint; consider corrosive to eyes. No testing is needed.Eye irritantApical endpoint; consider irritating to eyes. No testing is needed.Not corrosive/not irritating to eyesApical endpoint; considered non-corrosive and non-irritating to eyes. No testing required.Existing human and/or animal data showing corrosive effects on skinSkin corrosiveAssume corrosivity to eyes. No testing is needed.Existing human and/or animal data showing severe irritant effects on skinSevere skin irritantAssume irritating to eyes. No testing is needed.↓no information available, or available information is not conclusive↓2Perform SAR for eye corrosion/irritationPredict severe damage to eyesAssume corrosivity to eyes. No testing is needed.Predict irritation to eyesAssume irritating to eyes. No testing is needed.Perform SAR for skin corrosionPredict skin corrosivityAssume corrosivity to eyes. No testing is needed.↓No predictions can be made, or predictions are not conclusive or negative↓3Measure pH (buffering capacity, if relevant)pH ≤ 2 or ≥ 11.5 (with high buffering capacity, if relevant)Assume corrosivity to eyes. No testing is needed.↓2< pH < 11.5, or pH ≤ 2.0 or ≥ 11.5 with low/no buffering capacity, if relevant↓4Evaluate systemic toxicity via the dermal routeVery toxic at concentrations that would be tested in the eyeSubstance would be too toxic for testing. No testing is needed.↓Such information is not available, or substance is not very toxic↓

5Perform validated and accepted in vitro or ex vivo test for eye corrosionCorrosive responseAssume corrosivity to eyes. No further testing is needed.↓Substance is not corrosive, or validated in vitro or ex vivo testing methods for eye corrosion are not yet available↓6Perform validated and accepted in vitro or ex vivo test for eye irritationIrritant responseAssume irritancy to eyes. No further testing is needed.↓Substance is not an irritant, or validated in vitro or ex vivo testing methods for eye irritation are not yet available↓7Experimentally assess in vivo skin irritation/corrosion potential (see Testing method B.4 including its Annex)Corrosive or severe irritant responseAssume corrosivity to eyes. No further testing is needed.↓Substance is not corrosive or severely irritating to skin↓8Perform initial in vivo rabbit eye test using one animalSevere damage to eyesConsider corrosive to eyes. No further testing is needed.↓No severe damage, or no response↓9Perform confirmatory test using one or two additional animalsCorrosive or irritatingConsider corrosive or irritating to eyes. No further testing is neededNot corrosive or irritatingConsider non-irritating and non-corrosive to eyes. No further testing is needed.

B.6.   SKIN SENSITISATION

1.   METHOD

1.1.   INTRODUCTION

Remarks:

The sensitivity and ability of tests to detect potential human skin sensitisers are considered important in a classification system for toxicity relevant to public health.

There is no single test method which will adequately identify all substances with a potential for sensitising human skin and which is relevant for all substances.

Factors such as the physical characteristics of a substance, including its ability to penetrate the skin, must be considered in the selection of a test.

Two types of tests using guinea pigs have been developed: the adjuvant-type tests, in which an allergic state is potentiated by dissolving or suspending the test substance in Freunds Complete Adjuvant (FCA), and the non-adjuvant tests.

Adjuvant-type tests are likely to be more accurate in predicting a probable skin sensitising effect of a substance in humans than those methods not employing Freunds Complete Adjuvant and are thus the preferred methods.

The Guinea-Pig Maximisation Test (GPMT) is a widely used adjuvant-type test. Although several other methods can be used to detect the potential of a substance to provoke skin sensitisation reaction, the GPMT is considered to be the preferred adjuvant technique.

With many chemical classes, non-adjuvant tests (the preferred one being the Buehler test) are considered to be less sensitive.

In certain cases there may be good reasons for choosing the Buehler test involving topical application rather than the intradermal injection used in the Guinea-Pig Maximisation Test. Scientific justification should be given when the Buehler test is used.

The Guinea-Pig Maximisation Test (GPMT) and the Buehler test are described in this method. Other methods may be used provided that they are well-validated and scientific justification is given.

If a positive result is seen in a recognised screening test, a test substance may be designated as a potential sensitiser, and it may not be necessary to conduct a further guinea pig test. However, if a negative result is seen in such a test, the guinea pig test must be conducted using the procedure described in this tes method.

See also General introduction Part B.

1.2.   DEFINITIONS

Skin sensitisation: (allergic contact dermatitis) is an immunologically mediated cutaneous reaction to a substance. In the human, the responses may be characterised by pruritis, erythema, oedema, papules, vesicles, bullae or a combination of these. In other species the reactions may differ and only erythema and oedema may be seen.

Induction exposure: an experimental exposure of a subject to a test substance with the intention of inducing a hypersensitive state.

Induction period: a period of at least one week following an induction exposure during which a hypersensitive state may be developed.

Challenge exposure: an experimental exposure of a previously treated subject to a test substance following an induction period, to determine if the subject reacts in a hypersensitive manner.

1.3.   REFERENCE SUBSTANCES

The sensitivity and reliability of the experimental technique used should be assessed every six months by use of substances, which are known to have mild-to-moderate skin sensitisation properties.

In a properly conducted test, a response of at least 30 % in an adjuvant test and at least 15 % in a non-adjuvant test should be expected for mild/moderate sensitisers.

The following substances are preferred.



CAS numbers

EINECS numbers

EINECS names

Common names

101-86-0

202-983-3

α-hexylcinnamaldehyde

α-hexylcinnamaldehyde

149-30-4

205-736-8

Benzothiazole-2-thiol (mercaptobenzothiazole)

kaptax

94-09-7

202-303-5

Benzocaine

norcaine

There may be circumstances where, given adequate justification other control substances meeting the above criteria may be used.

1.4.   PRINCIPLE OF THE TEST METHOD

The test animals are initially exposed to the test substance by intradermal injections and/or epidermal application (induction exposure). Following a rest period of 10 to 14 days (induction period), during which an immune response may develop, the animals are exposed to a challenge dose. The extent and degree of skin reaction to the challenge exposure in the test animals is compared with that demonstrated by control animals which undergo sham treatment during induction and receive the challenge exposure.

1.5.   DESCRIPTION OF THE TEST METHODS

If removal of the test substance is considered necessary, this should be achieved using water or an appropriate solvent without altering the existing response or the integrity of the epidermis.

1.5.1.    Guinea-Pig Maximisation Test (GPMT)

1.5.1.1.    Preparations

Healthy young adult albino guinea pigs are acclimatised to the laboratory conditions for at least five days prior to the test. Before the test, animals are randomised and assigned to the treatment groups. Removal of hair is by clipping, shaving or possibly by chemical depilation, depending on the test method used. Care should be taken to avoid abrading the skin. The animals are weighed before the test commences and at the end of the test.

1.5.1.2.    Test conditions

1.5.1.2.1.   Test animals

Commonly used laboratory strains of albino guinea-pigs are used.

1.5.1.2.2.   Number and sex

Male and/or female animals can be used. If females are used, they should be nulliparous and non-pregnant.

A minimum of 10 animals is used in the treatment group and at least five animals in the control group. When fewer than 20 test and 10 control guinea pigs have been used, and it is not possible to conclude that the test substance is a sensitiser, testing in additional animals to give a total of at least 20 test and 10 control animals is strongly recommended.

1.5.1.2.3.   Dose levels

The concentration of the test substance used for each induction exposure should be well-tolerated systemically and should be the highest to cause mild-to-moderate skin irritation. The concentration used for the challenge exposure should be the highest non-irritant dose. The appropriate concentrations should be determined from a pilot study using two or three animals, if other information is not available. Consideration should be given to the use of FCA-treated animals for this purpose.

1.5.1.3.    Procedure

1.5.1.3.1.   Induction

Day 0-treated group

Three pairs of intradermal injections of 0,1 ml volume are given in the shoulder region which is cleared of hair so that one of each pair lies on each side of the midline.

Injection 1: a 1:1 mixture (v/v) FCA/water or physiological saline.

Injection 2: the test substance in an appropriate vehicle at the selected concentration.

Injection 3: the test substance at the selected concentration formulated in a 1:1 mixture (v/v) FCA/water or physiological saline.

In injection 3, water soluble substances are dissolved in the aqueous phase prior to mixing with FCA. Liposoluble or insoluble substances are suspended in FCA prior to combining with the aqueous phase. The final concentration of test substance shall be equal to that used in injection 2.

Injections 1 and 2 are given close to each other and nearest the head, while 3 is given towards the caudal part of the test area.

Day 0-control group

Three pairs of intradermal injections of 0,1 ml volume are given in the same sites as in the treated animals.

Injection 1: a 1:1 mixture (v/v) FCA/water or physiological saline.

Injection 2: the undiluted vehicle.

Injection 3: a 50 % w/v formulation of the vehicle in a 1:1 mixture (v/v) FCA/water or physiological saline.

Day 5-7-treated and control groups

Approximately 24 hours before the topical induction application, if the substance is not a skin irritant, the test area, after close-clipping and/or shaving is treated with 0,5 ml of 10 % sodium lauryl sulphate in vaseline, in order to create a local irritation.

Day 6-8-treated group

The test area is again cleared of hair. A filter paper (2 × 4 cm) is fully-loaded with test substance in a suitable vehicle and applied to the test area and held in contact by an occlusive dressing for 48 hours. The choice of the vehicle should be justified. Solids are finely pulverised and incorporated in a suitable vehicle. Liquids can be applied undiluted, if appropriate.

Day 6-8-control group

The test area is again cleared of hair. The vehicle only is applied in a similar manner to the test area and held in contact by an occlusive dressing for 48 hours.

1.5.1.3.2.   Challenge

Day 20-22-treated and control groups

The flanks of treated and control animals are cleared of hair. A patch or chamber loaded with the test substance is applied to one flank of the animals and, when relevant, a patch or chamber loaded with the vehicle only may also be applied to the other flank. The patches are held in contact by an occlusive dressing for 24 hours.

1.5.1.3.3.   Observation and Grading: treated and control groups

 approximately 21 hours after removing the patch the challenge area is cleaned and closely-clipped and/or shaved and depilated if necessary;

 approximately three hours later (approximately 48 hours from the start of the challenge application) the skin reaction is observed and recorded according to the grades shown in the Appendix;

 approximately 24 hours after this observation a second observation (72 hours) is made and once again recorded.

Blind reading of test and control animals is encouraged.

If it is necessary to clarify the results obtained in the first challenge, a second challenge (i.e. a rechallenge), where appropriate with a new control group, should be considered approximately one week after the first one. A rechallenge may also be performed on the original control group.

All skin reactions and any unusual findings, including systemic reactions, resulting from induction and challenge procedures should be observed and recorded according to the grading scale of Magnusson/Kligman (See Appendix). Other procedures, e.g. histopathological examination, the measurement of skin fold thickness, may be carried out to clarify doubtful reactions.

1.5.2.    Buehler test

1.5.2.1.    Preparations

Healthy young adult albino guinea-pigs are acclimatised to the laboratory conditions for at least five days prior to the test. Before the test, animals are randomised and assigned to the treatment groups. Removal of hair is by clipping, shaving or possibly by chemical depilation, depending on the test method used. Care should be taken to avoid abrading the skin. The animals are weighed before the test commences and at the end of the test.

1.5.2.2.    Test conditions

1.5.2.2.1.   Test animals

Commonly used laboratory strains of albino guinea-pigs are used.

1.5.2.2.2.   Number and sex

Male and/or female animals can be used. If females are used, they should be nulliparous and non-pregnant.

A minimum of 20 animals is used in the treatment group and at least 10 animals in the control group.

1.5.2.2.3.   Dose levels

The concentration of test substance used for each induction exposure should be the highest possible to produce a mild but not excessive irritation. The concentration used for the challenge exposure should be the highest non-irritating dose. If necessary, the appropriate concentration can be determined from a pilot study using two or three animals.

For water soluble test materials, it is appropriate to use water or a dilute non-irritating solution of surfactant as the vehicle. For other test materials 80 % ethanol/water is preferred for induction and acetone for challenge.

1.5.2.3.    Procedure

1.5.2.3.1.   Induction

Day 0-treated group

One flank is cleared of hair (closely-clipped). The test patch system should be fully loaded with test substance in a suitable vehicle (the choice of the vehicle should be justified; liquid test substances can be applied undiluted, if appropriate).

The test patch system is applied to the test area and held in contact with the skin by an occlusive patch or chamber and a suitable dressing for six hours.

The test patch system must be occlusive. A cotton pad is appropriate and can be circular or square, but should approximate 4-6 cm2. Restraint using an appropriate restrainer is preferred to assure occlusion. If wrapping is used, additional exposures may be required.

Day 0-control group

One flank is cleared of hair (closely-clipped). The vehicle only is applied in a similar manner to that used for the treated group. The test patch system is held in contact with the skin by an occlusive patch or chamber and a suitable dressing for six hours. If it can be demonstrated that a sham control group is not necessary, a naive control group may be used.

Days 6-8 and 13-15-treated and control group

The same application as on day 0 is carried out on the same test area (cleared of hair if necessary) of the same flank on day 6-8, and again on day 13-15.

1.5.2.3.2.   Challenge

Day 27-29-treated and control group

The untreated flank of treated and control animals is cleared of hair (closely-clipped). An occlusive patch or chamber containing the appropriate amount of test substance is applied, at the maximum non-irritant concentration, to the posterior untreated flank of treated and control animals.

When relevant, an occlusive patch or chamber with vehicle only is also applied to the anterior untreated flank of both treated and control animals. The patches or chambers are held in contact by a suitable dressing for six hours.

1.5.2.3.3.   Observation and grading

 approximately 21 hours after removing the patch the challenge area is cleared of hair,

 approximately three hours later (approximately 30 hours after application of the challenge patch) the skin reactions are observed and recorded according to the grades shown in the Appendix,

 approximately 24 hours after the 30 hour observation (approximately 54 hours after application of the challenge patch) skin reactions are again observed and recorded.

Blind reading of the test and control animals is encouraged.

If it is necessary to clarify the results obtained in the first challenge, a second challenge (i.e. a rechallenge), where appropriate with a new control group, should be considered approximately one week after the first one. A rechallenge may also be performed on the original control group.

All skin reactions and any unusual findings, including systemic reactions, resulting from induction and challenge procedures should be observed and recorded according to the Magnusson/Kligman grading scale (See Appendix). Other procedures, e.g. histopathological examination, the measurement of skin fold thickness, may be carried out to clarify doubtful reactions.

2.   DATA (GPMT and Buehler test)

Data should be summarised in tabular form, showing for each animal the skin reactions at each observation.

3.   REPORTING (GPMT and Buehler test)

If a screening assay is performed before the guinea pig test the description or reference of the test (e.g. Mouse Ear Swelling Test (MEST)), including details of the procedure, must be given together with results obtained with the test and reference substances.

Test report (GMPT and Buehler test)

The test report shall, if possible, include the following information:

Test animals:

 strain of guinea-pig used,

 number, age and sex of animals,

 source, housing conditions, diet, etc.,

 individual weights of animals at the start of the test.

Test conditions:

 technique of patch site preparation,

 details of patch materials used and patching technique,

 result of pilot study with conclusion on induction and challenge concentrations to be used in the test,

 details of test substance preparation, application and removal,

 justification for choice of vehicle,

 vehicle and test substance concentrations used for induction and challenge exposures and the total amount of substance applied for induction and challenge.

Results:

 a summary of the results of the latest sensitivity and reliability check (see 1.3) including information on substance, concentration and vehicle used,

 on each animal including grading system,

 narrative description of the nature and degree effects observed,

 any histopathological findings.

Discussion of results.

Conclusions.

4.   REFERENCES

This method is analogous to OECD TG 406.

Appendix

TABLE

Magnusson/Kligman grading scale for the evaluation of challenge patch test reactions

0 = no visible change

1 = discrete or patchy erythema

2 = moderate and confluent erythema

3 = intense erythema and swelling

B.7.   REPEATED DOSE (28 DAYS) TOXICITY (ORAL)

1.   METHOD

1.1.   INTRODUCTION

See General introduction Part B.

1.2.   DEFINITIONS

See General introduction Part B.

1.3.   PRINCIPLE OF THE TEST METHOD

The test substance is orally administered daily in graduated doses to several groups of experimental animals, one dose level per group for a period of 28 days. During the period of administration the animals are observed closely, each day for signs of toxicity. Animals which die or are killed during the test are necropsied and at the conclusion of the test surviving animals are killed and necropsied.

This method places more emphasis on neurological effects as a specific endpoint, and the need for careful clinical observations of the animals, so as to obtain as much information as possible, is stressed. The method should identify chemicals with neurotoxic potential, which may warrant further indepth investigation of this aspect. In addition, the method may give an indication of immunological effects and reproductive organ toxicity.

1.4.   DESCRIPTION OF THE TEST METHOD

1.4.1.   Preparations

Healthy young adult animals are randomly assigned to the control and treatment groups. Cages should be arranged in such a way that possible effects due to cage placement are minimised. The animals are identified uniquely and kept in their cages for at least five days prior to the start of the study to allow for acclimatisation to the laboratory conditions.

The test substance is administered by gavage or via the diet or drinking water. The method of oral administration is dependent on the purpose of the study, and the physical/chemical properties of the substance.

Where necessary, the test substance is dissolved or suspended in a suitable vehicle. It is recommended that, wherever possible, the use of an aqueous solution/suspension be considered first, followed by consideration of a solution/emulsion in oil (e.g. corn oil) and then by possible solution in other vehicles. For vehicles other than water the toxic characteristics of the vehicle must be known. The stability of the test substance in the vehicle should be determined.

1.4.2.   Test conditions

1.4.2.1.   Test animals

The preferred rodent species is the rat, although other rodent species may be used. Commonly used laboratory strains of young healthy adult animals should be employed. The females should be nulliparous and non-pregnant. Dosing should begin as soon as possible after weaning and, in any case, before the animals are nine weeks old.

At the commencement of the study the weight variation of animals used should be minimal and not exceed ± 20 % of the mean weight of each sex.

Where a repeated dose oral study is conducted as a preliminary to a long term-study, preferably animals from the same strain and source should be used in both studies.

1.4.2.2.   Number and sex

At least 10 animals (five female and five male) should be used at each dose level. If interim kills are planned, the number should be increased by the number of animals scheduled to be killed before the completion of the study.

In addition, a satellite group of 10 animals (five animals per sex) may be treated with the high dose level for 28 days and observed for reversibility, persistence, or delayed occurrence of toxic effects for 14 days post-treatment. A satellite group of 10 control animals (five animals per sex) is also used.

1.4.2.3.   Dose levels

Generally, at least three test groups and a control group should be used. Except for treatment with the test substance, animals in the control group should be handled in an identical manner to the test group subjects. If a vehicle is used in administering the test substance, the control group should receive the vehicle in the highest volume used.

If from assessment of other data, no effects would be expected at a dose of 1 000 mg/kg bw/d, a limit test may be performed. If there are no suitable data available, a range finding study may be performed to aid the determination of the doses to be used.

Dose levels should be selected taking into account any existing toxicity and (toxico-) kinetic data available for the test substance or related materials. The highest dose level should be chosen with the aim of inducing toxic effects but not death or severe suffering. Thereafter, a descending sequence of dose levels should be selected with a view to demonstrating any dosage related response and no-observed-adverse effects at the lowest dose level (NOAEL). Two to four fold intervals are frequently optimal for setting the descending dose levels and addition of a fourth test group is often preferable to using very large intervals (e.g. more than a factor of 10) between dosages.

For substances administered via the diet or drinking water it is important to ensure that the quantities of the test substance involved do not interfere with normal nutrition or water balance. When the test substance is administered in the diet either a constant dietary concentration (ppm) or a constant dose level in terms of the animals' body weight may be used; the alternative used must be specified. For a substance administered by gavage, the dose should be given at similar times each day, and adjusted as necessary to maintain a constant dose level in terms of animal body weight.

Where a repeated dose study is used as a preliminary to a long term-study, a similar diet should be used in both studies.

1.4.2.4.   Limit test

If a test at one dose level of at least 1 000 mg/kg body weight/day or, for dietary or drinking water administration, an equivalent percentage in the diet or drinking water (based upon body weight determinations), using the procedures described for this study, produces no observable toxic effects and if toxicity would not be expected based upon data from structurally related substances, then a full study using three dose levels may not be considered necessary. The limit test applies except when human exposure indicates the need for a higher dose level to be used.

1.4.2.5.   Observation period

The observation period should be 28 days. Animals in a satellite group scheduled for follow-up observations should be kept for at least a further 14 days without treatment to detect delayed occurrence, or persistence of, or recovery from toxic effects.

1.4.3.   Procedure

The animals are dosed with the test substance daily seven days each week for a period of 28 days; use of a five-day per week dosing regime needs to be justified. When the test substance is administered by gavage, this should be done in a single dose to the animals using a stomach tube or a suitable intubation cannula. The maximum volume of liquid that can be administered at one time depends on the size of the test animal. The volume should not exceed 1 ml/100 g body weight, except in the case of aqueous solutions where 2 ml/100 g body weight may be used. Except for irritating or corrosive substances, which will normally reveal exacerbated effects with higher concentrations, variability in test volume should be minimised by adjusting the concentration to ensure a constant volume at all dose levels.

1.4.3.1.   General observations

General clinical observations should be made at least once a day, preferably at the same time(s) each day and considering the peak period of anticipated effects after dosing. The health condition of the animals should be recorded. At least twice daily, all animals are observed for morbidity and mortality. Moribund animals and animals in severe distress or pain should be removed when noticed, humanely killed and necropsied.

Once before the first exposure (to allow for within-subject comparisons), and at least once a week thereafter, detailed clinical observations should be made in all animals. These observations should be made outside the home cage in a standard arena and preferably at the same time, each time. They should be carefully recorded, preferably using scoring systems, explicitly defined by the testing laboratory. Effort should be made to ensure that variations in the test conditions are minimal and that observations are preferably conducted by observers unaware of the treatment. Signs noted should include, but not be limited to, changes in skin, fur, eyes, mucous membranes, occurrence of secretions and excretions and autonomic activity (e.g. lacrimation, piloerection, pupil size, unusual respiratory pattern). Changes in gait, posture and response to handling as well as the presence of clonic or tonic movements, stereotypes (e.g. excessive grooming, repetitive circling) or bizarre behaviour (e.g. self-mutilation, walking backwards) should also be recorded.

In the fourth exposure week sensory reactivity to stimuli of different types (e.g. auditory, visual and proprioceptive stimuli), assessment of grip strength and motor activity assessment should be conducted. Further details of the procedures that could be followed are given in the literature (see General introduction Part B).

Functional observations conducted in the fourth exposure week may be omitted when the study is conducted as a preliminary study to a subsequent subchronic (90-day) study. In that case, the functional observations should be included in this follow-up study. On the other hand, the availability of data on functional observations from the repeated dose study may enhance the ability to select dose levels for a subsequent subchronic study.

Exceptionally, functional observations may also be omitted for groups that otherwise reveal signs of toxicity to an extent that would significantly interfere with the functional test performance.

1.4.3.2.   Body weight and food/water consumption

All animals should be weighed at least once a week. Measurements of food and water consumption should be made at least weekly. If the test substance is administered via the drinking water, water consumption should also be measured at least weekly.

1.4.3.3.   Haematology

The following haematological examinations should be made at the end of the test period: haematocrit, haemoglobin concentration, erythrocyte count, total and differential leucocyte count, platelet count and a measure of blood clotting time/potential.

Blood samples should be taken from a named site just prior to or as part of the procedure for killing the animals, and stored under appropriate conditions.

1.4.3.4.   Clinical biochemistry

Clinical biochemistry determinations to investigate major toxic effects in tissues and, specifically, effects on kidney and liver, should be performed on blood samples obtained of all animals just prior to or as part of the procedure for killing the animals (apart from those found moribund and/or intercurrently killed). Overnight fasting of the animals prior to blood sampling is recommended ( 16 ). Investigations of plasma or serum shall include sodium, potassium, glucose, total cholesterol, urea, creatinine, total protein and albumin, at least two enzymes indicative of hepatocellular effects (such as alanine aminotransferase, aspartate aminotransferase, alkaline phosphatase, gamma glutamyl transpeptidase, and sorbitol dehydrogenase). Measurements of additional enzymes (of hepatic or other origin) and bile acids may provide useful information under certain circumstances.

Optionally, the following urine analysis determinations could be performed during the last week of the study using timed urine volume collection; appearance, volume, osmolality or specific gravity, pH, protein, glucose and blood/blood cells.

In addition, studies to investigate serum markers of general tissue damage should be considered. Other determinations that should be carried out if the known properties of the test substance may, or are suspected to, affect related metabolic profiles include calcium, phosphate, fasting triglycerides, specific hormones, methaemoglobin and cholinesterase. These need to be identified for substances in certain classes or on a case-by-case basis.

Overall, there is a need for a flexible approach, depending on the species and the observed and/or expected effect with a given substance.

If historical baseline data are inadequate, consideration should be given to determination of haematological and clinical biochemistry variables before dosing commences.

1.4.3.5.   Gross necropsy

All animals in the study shall be subjected to a full, detailed gross necropsy, which includes careful examination of the external surface of the body, all orifices, and the cranial, thoracic and abdominal cavities and their contents. The liver, kidneys, adrenals, testes, epididymides, thymus, spleen, brain and heart of all animals should be trimmed of any adherent tissue, as appropriate, and their wet weight taken as soon as possible after dissection to avoid drying.

The following tissues should be preserved in the most appropriate fixation medium for both the type of tissue and the intended subsequent histopathological examination: all gross lesions, brain (representative regions including cerebrum, cerebellum and pons), spinal cord, stomach, small and large intestines (including Peyer's patches), liver, kidneys, adrenals, spleen, heart, thymus, thyroid, trachea and lungs (preserved by inflation with fixative and then immersion), gonads, accessory sex organs (e.g. uterus, prostate), urinary bladder, lymph nodes (preferably one lymph node covering the route of administration and another one distant from the route of administration to cover systemic effects), peripheral nerve (sciatic or tibial) preferably in close proximity to the muscle, and a section of bone marrow (or, alternatively, a fresh mounted bone marrow aspirate). The clinical and other findings may suggest the need to examine additional tissues. Also any organs considered likely to be target organs based on the known properties of the test substance should be preserved.

1.4.3.6.   Histopathological examination

Full histopathology should be carried out on the preserved organs and tissues of all animals in the control and high dose groups. These examinations should be extended to animals of all other dosage groups, if treatment-related changes are observed in the high dose group.

All gross lesions shall be examined.

When a satellite group is used, histopathology should be performed on tissues and organs identified as showing effects in the treated groups.

2.   DATA

Individual data should be provided. Additionally, all data should be summarised in tabular form showing for each test group the number of animals at the start of the test, the number of animals found dead during the test or killed for humane reasons and the time of any death or humane kill, the number showing signs of toxicity, a description of the signs of toxicity observed, including time of onset, duration, and severity of any toxic effects, the number of animals showing lesions, the type of lesions and the percentage of animals displaying each type of lesion.

When possible, numerical results should be evaluated by an appropriate and generally acceptable statistical method. The statistical methods should be selected during the design of the study.

3.   REPORTING

TEST REPORT

The test report shall, if possible, include the following information:

Test animals:

 species/strain used,

 number, age and sex of animals,

 source, housing conditions, diet, etc.,

 individual weights of animals at the start of the test in weekly intervals thereafter and at the end of the test.

Test conditions:

 justification for choice of vehicle, if other than water,

 rationale for dose level selection,

 details of test substance formulation/diet preparation, achieved concentration, stability and homogeneity of the preparation,

 details of the administration of the test substance,

 conversion from diet/drinking water test substance concentration (ppm) to the actual dose (mg/kg body weight/day), if applicable,

 details of food and water quality.

Results:

 body weight/body weight changes,

 food consumption, and water consumption, if applicable,

 toxic response data by sex and dose level, including signs of toxicity,

 nature, severity and duration of clinic observations (whether reversible or not),

 sensory activity, grip strength and motor activity assessments,

 haematological tests with relevant base-line values,

 clinical biochemistry tests with relevant base-line values,

 body weight at killing and organ weight data,

 necropsy findings,

 a detailed description of all histopathological findings,

 absorption data if available,

 statistical treatment of results, where appropriate.

Discussion of results.

Conclusions.

4.   REFERENCES

This method is analogous to OECD TG 407.

B.8.   REPEATED DOSE (28 DAYS) TOXICITY (INHALATION)

1.   METHOD

1.1.   INTRODUCTION

It is useful to have preliminary information on the particle size distribution, the vapour pressure, the melting point, the boiling point, the flash point and explosivity (if applicable) of the substance.

See also General introduction Part B (A).

1.2.   DEFINITION

See General introduction Part B (B).

1.3.   REFERENCE SUBSTANCES

None.

1.4.   PRINCIPLE OF THE TEST METHOD

Several groups of experimental animals are exposed daily for a defined period to the test substance in graduated concentrations, one concentration being used per group, for a period of 28 days. Where a vehicle is used to help generate an appropriate concentration of the test substance in the atmosphere, a vehicle control group should be used. During the period of administration the animals are observed daily to detect signs of toxicity. Animals, which die during the test are necropsied and at the conclusion of the test surviving animals are necropsied.

1.5.   QUALITY CRITERIA

None.

1.6.   DESCRIPTION OF THE TEST METHOD

1.6.1.   Preparations

The animals are kept under the experimental housing and feeding conditions for at least five days prior to the experiment. Before the test, healthy young animals are randomised and assigned to the required number of groups. Where necessary, a suitable vehicle may be added to the test substance to help generate an appropriate concentration of the substance in the atmosphere. If a vehicle or other additive is used to facilitate dosing, it should be known not to produce toxic effects. Historical data can be used if appropriate.

1.6.2.   Test conditions

1.6.2.1.   Experimental animals

Unless there are contra-indications, the rat is the preferred species. Commonly used laboratory strains of young healthy animals should be employed.

At the commencement of the study the range of weight variation in the animals used should not exceed ± 20 % of the appropriate mean value.

1.6.2.2.   Number and sex

At least 10 animals (five female and five male) should be used for each test group. The females should be nulliparous and non-pregnant. If interim sacrifices are planned, the numbers should be increased by the number of animals scheduled to be sacrificed before the completion of the study. In addition, a satellite group of 10 animals (five animals per sex) may be treated with the high concentration level for 28 days and observed for reversibility, persistence, or delayed occurrence of toxic effects for 14 days post-treatment. A satellite group of 10 control animals (five animals per sex) is also used.

1.6.2.3.   Exposure concentration

At least three concentrations are required, with a control or a vehicle control (corresponding to the concentration of vehicle at the highest level) if a vehicle is used. Except for treatment with the test substance, animals in the control group should be handled in an identical manner to the test-group animals. The highest concentration should result in toxic effects but no, or few, fatalities. The lowest concentration should not produce any evidence of toxicity. Where there is a usable estimation of human exposure, the lowest concentration should exceed this. Ideally, the intermediate concentration should produce minimal observable toxic effects. If more than one intermediate concentration is used the concentrations should be spaced to produce a gradation of toxic effects. In the low and intermediate groups and in the controls, the incidence of fatalities should be low to permit a meaningful evaluation of the results.

1.6.2.4.   Exposure time

The duration of daily exposure should be six hours but other periods may be needed to meet specific requirements.

1.6.2.5.   Equipment

The animals should be tested in inhalation equipment designed to sustain a dynamic airflow of at least 12 air changes per hour to ensure an adequate oxygen content and an evenly distributed exposure atmosphere. Where a chamber is used its design should minimise crowding of the test animals and maximise their exposure by inhalation of the test substance. As a general rule to ensure stability of a chamber atmosphere the total ‘volume’ of the test animals should not exceed 5 % of the volume of the test chamber. Oro-nasal, head only, or individual whole body chamber exposure may be used; the first two will minimise uptake by other routes.

1.6.2.6.   Observation period

The experimental animals should be observed daily for signs of toxicity during the entire treatment and recovery period. The time of death and the time at which signs of toxicity appear and disappear should be recorded.

1.6.3.   Procedure

The animals are exposed to the test substance daily, five to seven days per week, for a period of 28 days. Animals in any satellite groups scheduled for follow-up observations should be kept for a further 14 days without treatment to detect recovery from, or persistence of toxic effects. The temperature at which the test is performed should be maintained at 22 ± 3 oC.

Ideally, the relative humidity should be maintained between 30 and 70 %, but in certain instances (e.g. tests of some aerosols) this may not be practicable. Maintenance of a slight negative pressure inside the chamber (≤ 5 mm of water) will prevent leakage of the test substance into the surrounding area. Food and water should be withheld during exposure.

A dynamic inhalation system with a suitable analytical concentration control system should be used. To establish suitable exposure concentrations a trial test is recommended. The airflow should be adjusted to ensure that conditions throughout the exposure chamber are homogeneous. The system should ensure that stable exposure conditions are achieved as rapidly as possible.

Measurements or monitoring should be made:

(a) of the rate of airflow (continuously),

(b) of the actual concentration of the test substance measured in the breathing zone. During the daily exposure period the concentration should not vary by more than ± 15 % of the mean value. However, in the case of some aerosols, this level of control may not be achievable and a wider range would then be acceptable. During the total duration of the study, the day-to-day concentrations should be held as constant as practicable. For aerosols, at least one particle size analysis should be performed per test group weekly,

(c) of temperature and humidity, continuously if possible.

During and following exposure observations are made and recorded systematically; individual records should be maintained for each animal. All the animals should be observed daily and signs of toxicity recorded including the time of onset, their degree and duration. Observations should include changes in the skin and fur, eyes, mucous membranes, respiratory, circulatory, autonomic and central nervous systems, somatomotor activity and behaviour pattern. Measurements should be made weekly of the animals' weight. It is also recommended that food consumption is measured weekly. Regular observation of the animals is necessary to ensure that animals are not lost from the study due to causes such as cannibalism, autolysis of tissues or misplacement. At the end of the study period, all survivors in the non-satellite treatment groups are necropsied. Moribund animals and animals in severe distress or pain should be removed when noticed, humanely killed and necropsied.

The following examinations shall be made at the end of the test on all animals including the controls:

(i) haematology, including at least haematocrit, haemoglobin concentration, erythrocyte count, total and differential leucocyte count and a measure of clotting potential;

(ii) clinical blood biochemistry including at least one parameter of liver and kidney function: serum alanine aminotransferase (formerly known as glutamic pyruvic transaminase), serum aspartate aminotransferase (formerly known as glutamic oxaloacetic transaminase), urea nitrogen, albumin, blood creatinine, total bilirubin and total serum protein measurements;

Other determinations, which may be necessary for an adequate toxicological evaluation include calcium, phosphorus, chloride, sodium, potassium, fasting glucose analysis of lipids, hormones, acid/base balance, methaemoglobin and cholinesterase activity.

Additional clinical biochemistry may be employed, where necessary, to extend the investigation of observed toxic effects.

1.6.3.1.   Gross necropsy

All animals in the study should be subjected to a full gross necropsy. At least the liver, kidneys, adrenals, lungs, and testes should be weighed wet as soon as possible after dissection to avoid drying. Organs and tissues (the respiratory tract, liver, kidneys, spleen, testes, adrenals, heart, and any organs showing gross lesions or changes in size) should be preserved in a suitable medium for possible future histopathological examination. The lungs should be removed intact, weighed and treated with a suitable fixative to ensure that lung structure is maintained.

1.6.3.2.   Histopathological examination

In the high-concentration group and in the control(s), histological examination should be performed on preserved organs and tissues. Organs and tissues showing defects attributable to the test substance at the highest dosage level should be examined in all lower-dosage groups. Animals in any satellite groups should be examined histologically with particular emphasis on those organs and tissues identified as showing effects in the other treated groups.

2.   DATA

Data should be summarised in tabular form, showing for each test group the number of animals at the start of the test and the number of animals displaying each type of lesion.

All observed results should be evaluated by an appropriate statistical method. Any recognised statistical method may be used.

3.   REPORTING

3.1.   TEST REPORT

The test report shall, if possible, include the following information:

 species, strain, source, environmental conditions, diet, etc.,

 test conditions.

 Description of exposure apparatus including design, type, dimensions, source of air, system for generating aerosols, method of conditioning air, treatment of exhaust air and the method of housing animals in a test chamber when this is used. The equipment for measuring temperature, humidity and, where appropriate, stability of aerosol concentrations or particle size distribution, should be described.

 Exposure data:

 These should be tabulated and presented with mean values and a measure of variability (e.g. standard deviation) and shall, if possible, include:

 

(a) airflow rates through the inhalation equipment;

(b) temperature and humidity of air;

(c) nominal concentrations (total amount of test substance fed into the inhalation equipment divided by the volume of air);

(d) nature of vehicle, if used;

(e) actual concentrations in test breathing zone;

(f) the mass median aerodynamic diameter (MMAD) and the geometric standard deviation (GSD);

 toxic response data by sex and concentration,

 time of death during the study or whether animals survived to termination,

 description of toxic or other effects, no-effect level,

 the time of observation of each abnormal sign and its subsequent course,

 food and body-weight data,

 haematological tests employed and results,

 clinical biochemistry tests employed and results,

 necropsy findings,

 a detailed description of all histopathological findings,

 a statistical treatment of results where possible,

 discussion of the results,

 interpretation of results.

3.2.   EVALUATION AND INTERPRETATION

See General introduction Part B (D).

4.   REFERENCES

See General introduction Part B (E).

B.9.   REPEATED DOSE (28 DAYS) TOXICITY (DERMAL)

1.   METHOD

1.1.   INTRODUCTION

See General introduction Part B (A).

1.2.   DEFINITIONS

See General introduction Part B (B).

1.3.   REFERENCE SUBSTANCES

None.

1.4.   PRINCIPLE OF THE TEST METHOD

The test substance is applied daily to the skin in graduated doses to several groups of experimental animals, one dose per group, for a period of 28 days. During the period of application, the animals are observed daily to detect signs of toxicity. Animals, which die during the test, are necropsied and at the conclusion of the test surviving animals are necropsied.

1.5.   QUALITY CRITERIA

None.

1.6.   DESCRIPTION OF THE TEST METHOD

1.6.1.   Preparations

The animals are kept under the experimental housing and feeding conditions for at least five days prior to the test. Before the test, healthy young animals are randomised and assigned to the treatment and control groups. Shortly before testing, fur is clipped from the dorsal area of the trunk of the test animals. Shaving may be employed but it should be carried out approximately 24 hours before the test. Repeat clipping or shaving is usually needed at approximately weekly intervals. When clipping or shaving the fur, care must be taken to avoid abrading the skin. Not less than 10 % of the body surface area should be clear for the application of the test substance. The weight of the animal should be taken into account when deciding on the area to be cleared and on the dimensions of the covering. When testing solids, which may be pulverised if appropriate, the test substance should be moistened sufficiently with water or, where necessary, a suitable vehicle to ensure good contact with the skin. Liquid test substances are generally used undiluted. Daily application on a five to seven-day per week basis is used.

1.6.2.   Test conditions

1.6.2.1.   Experimental animals

The adult rat, rabbit or guinea-pig may be used. Other species may be used but their use would require justification.

At the commencement of the study, the range of weight variation in the animals used should not exceed ± 20 % of the appropriate mean value.

1.6.2.2.   Number and sex

At least 10 animals (five female and five male) with healthy skin should be used at each dose level. The females should be nulliparous and non-pregnant. If interim sacrifices are planned, the numbers should be increased by the number of animals scheduled to be sacrificed before the completion of the study. In addition, a satellite group of 10 animals (five animals per sex) may be treated with the high dose level for 28 days and observed for reversibility, persistence, or delayed occurrence of toxic effects for 14 days post-treatment. A satellite group of 10 control animals (five animals per sex) is also used.

1.6.2.3.   Dose levels

At least three dose levels are required with a control or a vehicle control if a vehicle is used. The exposure period should be at least six hours per day. The application of the test substance should be made at similar times each day, and adjusted at intervals (weekly or bi-weekly) to maintain a constant dose level in terms of animal body-weight. Except for treatment with the test substance, animals in the control group should be handled in an identical manner to the test group subjects. Where a vehicle is used to facilitate dosing, the vehicle control group should be dosed in the same way as the treated groups, and receive the same amount as that received by the highest dose level group. The highest dose level should result in toxic effects but produce no, or few, fatalities. The lowest dose level should not produce any evidence or toxicity. Where there is a usable estimation of human exposure, the lowest level should exceed this. Ideally, the intermediate dose level should produce minimal observable toxic effects. If more than one intermediate dose is used the dose levels should be spaced to produce a gradation of toxic effects. In the low and intermediate groups and in the controls, the incidence of fatalities should be low in order to permit a meaningful evaluation of the results.

If application of the test substance produces severe skin irritation, the concentrations should be reduced and this may result in a reduction in, or absence of, other toxic effects at the high dose level. Moreover if the skin has been badly damaged it may be necessary to terminate the study and undertake a new study at lower concentrations.

1.6.2.4.   Limit test

If a preliminary study at a dose level of 1 000 mg/kg, or a higher dose level related to possible human exposure where this is known, produces no toxic effects, further testing may not be considered necessary.

1.6.2.5.   Observation period

The experimental animals should be observed daily for signs of toxicity. The time of death and the time at which signs of toxicity appear and disappear should be recorded.

1.6.3.   Procedure

Animals should be caged individually. The animals are treated with the test substance, ideally on seven days per week, for a period of 28 days. Animals in any satellite groups scheduled for follow-up observations should be kept for a further 14 days without treatment to detect recovery from or persistence of toxic effects. Exposure time should be at least six hours per day.

The test substance should be applied uniformly over an area, which is approximately 10 % of the total body surface area. With highly toxic substances, the surface area covered may be less but as much of the area as possible should be covered with as thin and uniform a layer as possible.

During exposure the test substance is held in contact with the skin with porous gauze dressing and non-irritating tape. The test site should be further covered in a suitable manner to retain the gauze dressing and test substance and ensure that the animals cannot ingest the test substance. Restrainers may be used to prevent the ingestion of the test substance but complete immobilisation is not a recommended method. As an alternative a ‘collar protective device’ may be used.

At the end of the exposure period, residual test substance should be removed, where practicable, using water or some other appropriate method of cleansing the skin.

All the animals should be observed daily and signs of toxicity recorded including the time of onset, their degree and duration. Observations should include changes in skin and fur, eyes and mucous membranes as well as respiratory, circulatory, autonomic and central nervous systems, somatomotor activity and behaviour pattern. Measurements should be made weekly of the animals' weight. It is also recommended that food consumption is measured weekly. Regular observation of the animals is necessary to ensure that animals are not lost from the study due to causes such as cannibalism, autolysis of tissues or misplacement. At the end of the study period, all survivors in the non-satellite treatment groups are necropsied. Moribund animals and animals in severe distress or pain should be removed when noticed, humanely killed and necropsied.

The following examinations shall be made at the end of the test on all animals including the controls:

(1) haematology, including at least haematocrit, haemoglobin concentration, erythrocyte count, total and differential leucocyte count, and a measure of clotting potential;

(2) clinical blood biochemistry including at least one parameter of liver and kidney function: serum alanine aminotransferase (formerly known as glutamic pyruvic transaminase), serum aspartate aminotransferase (formerly known as glutamic oxaloacetic transaminase), urea nitrogen, albumin, blood creatinine, total bilirubin and total serum protein;

Other determinations which may be necessary for an adequate toxicological evaluation include calcium, phosphorus, chloride, sodium, potassium, fasting glucose, analysis of lipids, hormones, acid/base balance, methaemoglobin and cholinesterase activity.

Additional clinical biochemistry may be employed, where necessary, to extend the investigation of observed effects.

1.6.4.   Gross necropsy

All animals in the study should be subjected to a full gross necropsy. At least the liver, kidneys, adrenals, and testes should be weighed wet as soon as possible after dissection, to avoid drying. Organs and tissues, i.e. normal and treated skin, liver, kidney, spleen, testes, adrenals, heart, and target organs (that is those organs showing gross lesions or changes in size) should be preserved in a suitable medium for possible future histopathological examination.

1.6.5.   Histopathological examination

In the high dose group and in the control group, histological examination should be performed on the preserved organs and tissues. Organs and tissues showing defects attributable to the test substance at the highest dosage level should be examined in all lower-dosage groups. Animals in the satellite group should be examined histologically with particular emphasis on those organs and tissues identified as showing effects in the other treated groups.

2.   DATA

Data should be summarised in tabular form, showing for each test group the number of animals at the start of the test and the number of animals displaying each type of lesion.

All observed results should be evaluated by an appropriate statistical method. Any recognised statistical method may be used.

3.   REPORTING

3.1.   TEST REPORT

The test report shall, if possible, include the following information:

 animal data (species, strain, source, environmental conditions, diet, etc.),

 test conditions (including the type of dressing: occlusive or not-occlusive),

 dose levels (including vehicle, if used) and concentrations,

 no-effect level, where possible,

 toxic response data by sex and dose,

 time of death during the study or whether animals survived to termination,

 toxic or other effects,

 the time of observation of each abnormal sign and its subsequent course,

 food and body-weight data,

 haematological tests employed and results,

 clinical biochemistry tests employed and results,

 necropsy findings,

 a detailed description of all histopathological findings,

 statistical treatment of results where possible,

 discussion of the results,

 interpretation of the results.

3.2.   EVALUATION AND INTERPRETATION

See General introduction Part B (D).

4.   REFERENCES

See General introduction Part B (E).

B.10.   MUTAGENICITY — IN VITRO MAMMALIAN CHROMOSOME ABERRATION TEST

1.   METHOD

This method is a replicate of the OECD TG 473, In Vitro Mammalian Chromosome Aberration Test (1997).

1.1.   INTRODUCTION

The purpose of the in vitro chromosomal aberration test is to identify agents that cause structural chromosome aberrations in cultured mammalian cells (1)(2)(3). Structural aberrations may be of two types, chromosome or chromatid. With the majority of chemical mutagens, induced aberrations are of the chromatid type, but chromosome-type aberrations also occur. An increase in polyploidy may indicate that a chemical has the potential to induce numerical aberrations. However, this method is not designed to measure numerical aberrations and is not routinely used for that purpose. Chromosome mutations and related events are the cause of many human genetic diseases and there is substantial evidence that chromosome mutations and related events causing alterations in oncogenes and tumour-suppressor genes of somatic cells are involved in cancer induction in humans and experimental animals.

The in vitro chromosome aberration test may employ cultures of established cell lines, cell strains or primary cell cultures. The cells used are selected on the basis of growth ability in culture, stability of the karyotype, chromosome number, chromosome diversity and spontaneous frequency of chromosome aberrations.

Tests conducted in vitro generally require the use of an exogenous source of metabolic activation. This metabolic activation system cannot mimic entirely the mammalian in vivo conditions. Care should be taken to avoid conditions which would lead to positive results which do not reflect intrinsic mutagenicity and may arise from changes in pH, osmolality or high levels of cytotoxicity (4)(5).

This test is used to screen for possible mammalian mutagens and carcinogens. Many compounds that are positive in this test are mammalian carcinogens; however, there is not a perfect correlation between this test and carcinogenicity. Correlation is dependent on chemical class and there is increasing evidence that there are carcinogens that are not detected by this test because they appear to act through mechanisms other than direct DNA damage.

See also General introduction Part B.

1.2.   DEFINITIONS

Chromatid-type aberration: structural chromosome damage expressed as breakage of single chromatids or breakage and reunion between chromatids.

Chromosome-type aberration: structural chromosome damage expressed as breakage, or breakage and reunion, of both chromatids at an identical site.

Endoreduplication: a process in which after an S period of DNA replication, the nucleus does not go into mitosis but starts another S period. The result is chromosomes with four, eight, 16, …chromatids.

Gap: an achromatic lesion smaller than the width of one chromatid, and with minimum misalignment of the chromatids).

Mitotic index: the ratio of cells in metaphase divided by the total number of cells observed in a population of cells; an indication of the degree of proliferation of that population.

Numerical aberration: a change in the number of chromosomes from the normal number characteristic of the cells utilised.

Polyploidy: a multiple of the haploid chromosome number (n) other than the diploid number (i.e. 3n, 4n and so on).

Structural aberration: a change in chromosome structure detectable by microscopic examination of the metaphase stage of cell division, observed as deletions and fragments, intrachanges or interchanges.

1.3.   PRINCIPLE OF THE TEST METHOD

Cell cultures are exposed to the test substance both with and without metabolic activation. At predetermined intervals after exposure of cell cultures to the test substance, they are treated with a metaphase-arresting substance (e.g. Colcemid® or colchicine), harvested, stained and metaphase cells are analysed microscopically for the presence of chromosome aberrations.

1.4.   DESCRIPTION OF THE TEST METHOD

1.4.1.   Preparations

1.4.1.1.   Cells

A variety of cell lines, strains or primary cell cultures, including human cells, may be used (e.g. Chinese hamster fibroblasts, human or other mammalian peripheral blood lymphocytes).

1.4.1.2.   Media and culture conditions

Appropriate culture media and incubation conditions (culture vessels, CO2 concentration, temperature and humidity) should be used in maintaining cultures. Established cell lines and strains should be checked routinely for stability in the modal chromosome number and the absence of mycoplasma contamination and should not be used if contaminated. The normal cell cycle time for the cells and culture conditions used should be known.

1.4.1.3.   Preparation of cultures

Established cell lines and strains: cells are propagated from stock cultures, seeded in culture medium at a density such that the cultures will not reach confluency before the time of harvest, and incubated at 37 oC.

Lymphocytes: whole blood treated with an anti-coagulant (e.g. heparin) or separated lymphocytes obtained from healthy subjects are added to the culture medium containing a mitogen (e.g. phytohaemagglutinin) and incubated at 37 oC.

1.4.1.4.   Metabolic activation

Cells should be exposed to the test substance both in the presence and absence of an appropriate metabolic activation system. The most commonly used system is a cofactor-supplemented post-mitochondrial fraction (S9) prepared from the livers of rodents treated with enzyme-inducing agents such as: Aroclor 1254 (6)(7)(8)(9), or a mixture of phenobarbitone and ß–naphthoflavone (10)(11)(12).

The post-mitochondrial fraction is usually used at concentrations in the range from 1-10 % v/v in the final test medium. The condition of a metabolic activation system may depend upon the class of chemical being tested. In some cases it may be appropriate to utilise more than one concentration of post-mitochondrial fraction.

A number of developments, including the construction of genetically engineered cell lines expressing specific activating enzymes, may provide the potential for endogenous activation. The choice of the cell lines used should be scientifically justified (e.g. by the relevance of the cytochrome P450 isoenzyme for the metabolism of the test substance).

1.4.1.5.   Test substance/Preparation

Solid test substances should be dissolved or suspended in appropriate solvents or vehicles and diluted if appropriate prior to treatment of the cells. Liquid test substances may be added directly to the test systems and/or diluted prior to treatment. Fresh preparations of the test substance should be employed unless stability data demonstrate the acceptability of storage.

1.4.2.   Test conditions

1.4.2.1.   Solvent/vehicle

The solvent/vehicle should not be suspected of chemical reaction with the test substance and should be compatible with the survival of the cells and the S9 activity. If other than well-known solvent/vehicles are used, their inclusion should be supported by data indicating their compatibility. It is recommended that wherever possible, the use of an aqueous solvent/vehicle be considered first. When testing water-unstable substances, the organic solvents used should be free of water. Water can be removed by adding a molecular sieve.

1.4.2.2.   Exposure concentrations

Among the criteria to be considered when determining the highest concentration are cytotoxicity, solubility in the test system and changes in pH or osmolality.

Cytotoxicity should be determined with and without metabolic activation in the main experiment using an appropriate indication of cell integrity and growth, such as degree of confluency, viable cell counts, or mitotic index. It may be useful to determine cytotoxicity and solubility in a preliminary experiment.

At least three analysable concentrations should be used. Where cytotoxicity occurs, these concentrations should cover a range from the maximum to little or no toxicity; this will usually mean that the concentrations should be separated by no more than a factor between 2 and √10. At the time of harvesting, the highest concentration should show a significant reduction in degree of confluency, cell count or mitotic index, (all greater than 50 %). The mitotic index is only an indirect measure of cytotoxic/cytostatic effects and depends on the time after treatment. However, the mitotic index is acceptable for suspension cultures in which other toxicity measurements may be cumbersome and impractical. Information on cell cycle kinetics, such as average generation time (AGT), could be used as supplementary information. AGT, however, is an overall average that does not always reveal the existence of delayed subpopulations, and even slight increases in average generation time can be associated with very substantial delay in the time of optimal yield of aberrations.

For relatively non-cytotoxic substances, the maximum test concentration should be 5 μl/ml, 5 mg/ml or 0,01 M, whichever is the lowest.

For relatively insoluble substances that are not toxic at concentrations lower than the insoluble concentration, the highest dose used should be a concentration above the limit of solubility in the final culture medium at the end of the treatment period. In some cases (e.g. when toxicity occurs only at higher than the lowest insoluble concentration) it is advisable to test at more than one concentration with visible precipitation. It may be useful to assess solubility at the beginning and the end of the treatment, as solubility can change during the course of exposure in the test system due to presence of cells, S9, serum etc. Insolubility can be detected by using the unaided eye. The precipitate should not interfere with the scoring.

1.4.2.3.   Negative and positive controls

Concurrent positive and negative (solvent or vehicle) controls, both with and without metabolic activation, should be included in each experiment. When metabolic activation is used, the positive control chemical should be the one that requires activation to give a mutagenic response.

Positive controls should employ a known clastogen at exposure levels expected to give a reproducible and detectable increase over background, which demonstrates the sensitivity of the test system.

Positive control concentrations should be chosen so that the effects are clear but do not immediately reveal the identity of the coded slides to the reader. Examples of positive control substances include:



Metabolic Activation condition

Substance

CAS No

EINECS No

Absence of exogenous metabolic Activation

Methyl methanesulphonate

66-27-3

200-625-0

Ethyl methanesulphonate

62-50-0

200-536-7

Ethyl nitrosourea

759-73-9

212-072-2

Mitomycin C

50-07-7

200-008-6

4-Nitroquinoline-N-oxide

56-57-5

200-281-1

Presence of exogenous metabolic Activation

Benzo[a]pyrene

50-32-8

200-028-5

Cyclophosphamide

Cyclophosphamide monohydrate

50-18-0

6055-19-2

200-015-4

Other appropriate positive control substances may be used. The use of chemical class-related positive control chemicals should be considered, when available.

Negative controls, consisting of solvent or vehicle alone in the treatment medium, and treated in the same way as the treatment cultures, should be included for every harvest time. In addition, untreated controls should also be used unless there are historical control data demonstrating that no deleterious or mutagenic effects are induced by the chosen solvent.

1.4.3.   Procedure

1.4.3.1.   Treatment with the test substance

Proliferating cells are treated with the test substance in the presence and absence of a metabolic activation system. Treatment of lymphocytes should commence at about 48 hours after mitogenic stimulation.

1.4.3.2. Duplicate cultures should normally be used at each concentration, and are strongly recommended for negative/solvent control cultures. Where minimal variation between duplicate cultures can be demonstrated (13)(14), from historical data, it may be acceptable for single cultures to be used at each concentration.

Gaseous or volatile substances should be tested by appropriate methods, such as in sealed culture vessels (15)(16).

1.4.3.3.   Culture harvest time

In the first experiment, cells should be exposed to the test substance, both with and without metabolic activation, for three to six hours, and sampled at a time equivalent to about 1,5 normal cell cycle length after the beginning of treatment (12). If this protocol gives negative results both with and without activation, an additional experiment without activation should be done, with continuous treatment until sampling at a time equivalent to about 1,5 normal cell cycle lengths. Certain chemicals may be more readily detected by treatment/sampling times longer than 1,5 cycle lengths. Negative results with metabolic activation need to be confirmed on a case-by-case basis. In those cases where confirmation of negative results is not considered necessary, justification should be provided.

1.4.3.4.   Chromosome preparation

Cell cultures are treated with Colcemid® or colchicine usually for one to three hours prior to harvesting. Each cell culture is harvested and processed separately for the preparation of chromosomes. Chromosome preparation involves hypotonic treatment of the cells, fixation and staining.

1.4.3.5.   Analysis

All slides, including those of positive and negative controls, should be independently coded before microscopic analysis. Since fixation procedures often result in the breakage of a proportion of metaphase cells with loss of chromosomes, the cells scored should therefore contain a number of centromeres equal to the modal number ± 2 for all cell types. At least 200 well spread metaphases should be scored per concentration and control, equally divided amongst the duplicates, if applicable. This number can be reduced when high number of aberrations is observed.

Though the purpose of the test is to detect structural chromosome aberrations, it is important to record polyploidy and endoreduplication when these events are seen.

2.   DATA

2.1.   TREATMENT OF RESULTS

The experimental unit is the cell, and therefore the percentage of cells with structural chromosome aberration(s) should be evaluated. Different types of structural chromosome aberrations should be listed with their numbers and frequencies for experimental and control cultures. Gaps are recorded separately and reported but generally not included in the total aberration frequency.

Concurrent measures of cytotoxicity for all treated and negative control cultures in the main aberration experiments should also be recorded.

Individual culture data should be provided. Additionally, all data should be summarised in tabular form.

There is no requirement for verification of a clear positive response. Equivocal results should be clarified by further testing preferably using modification of experimental conditions. The need to confirm negative results has been discussed in 1.4.3.3. Modification of study parameters to extend the range of conditions assessed should be considered in follow-up experiments. Study parameters that might be modified include the concentration spacing and the metabolic activation conditions.

2.2.   EVALUATION AND INTERPRETATION OF RESULTS

There are several criteria for determining a positive result, such as a concentration-related increase or a reproducible increase in the number of cells with chromosome aberrations. Biological relevance of the results should be considered first. Statistical methods may be used as an aid in evaluating the test results (3)(13). Statistical significance should not be the only determining factor for a positive response.

An increase in the number of polyploid cells may indicate that the test substance has the potential to inhibit mitotic processes and to induce numerical chromosome aberrations. An increase in the number of cells with endoreduplicated chromosomes may indicate that the test substance has the potential to inhibit cell cycle progression (17)(18).

A test substance for which the results do not meet the above criteria is considered non-mutagenic in this system.

Although most experiments will give clearly positive or negative results, in rare cases the data set will preclude making a definite judgement about the activity of the test substance. Results may remain equivocal or questionable regardless of the number of times the experiment is repeated.

Positive results from the in vitro chromosome aberration test indicate that the test substance induces structural chromosome aberrations in cultured mammalian somatic cells. Negative results indicate that, under the test conditions, the test substance does not induce chromosome aberrations in cultured mammalian somatic cells.

3.   REPORTING

TEST REPORT

The test report must include the following information:

Solvent/Vehicle:

 justification for choice of vehicle,

 solubility and stability of the test substance in solvent/vehicle, if known.

Cells:

 type and source of cells,

 karyotype features and suitability of the cell type used,

 absence of mycoplasma, if applicable,

 information on cell cycle length,

 sex of blood donors, whole blood or separated lymphocytes, mitogen used,

 number of passages, if applicable,

 methods for maintenance of cell culture, if applicable,

 modal number of chromosomes.

Test conditions:

 identity of metaphase arresting substance, its concentration and duration of cell exposure,

 rationale for selection of concentrations and number of cultures including, e.g. cytotoxicity data and solubility limitations, if available,

 composition of media, CO2 concentration if applicable,

 concentration of test substance,

 volume of vehicle and test substance added,

 incubation temperature,

 incubation time,

 duration of treatment,

 cell density at seeding, if appropriate,

 type and composition of metabolic activation system, including acceptability criteria,

 positive and negative controls,

 methods of slide preparation,

 criteria for scoring aberrations,

 number of metaphases analysed,

 methods for the measurements of toxicity,

 criteria for considering studies as positive, negative or equivocal.

Results:

 signs of toxicity, e.g. degree of confluency, cell cycle data, cell counts, mitotic index,

 signs of precipitation,

 data on pH and osmolality of the treatment medium, if determined,

 definition for aberrations, including gaps,

 number of cells with chromosome aberrations and type of chromosome aberrations given separately for each treated and control culture,

 changes in ploidy if seen,

 dose-response relationship, where possible,

 statistical analyses, if any,

 concurrent negative (solvent/vehicle) and positive control data,

 historical negative (solvent/vehicle) and positive control data, with ranges, means and standard deviations.

Discussion of results.

Conclusions.

4.   REFERENCES

(1) Evans, H. J., (1976) Cytological Methods for Detecting Chemical Mutagens. In: Chemical mutagens, Principles and Methods for their Detection, Vol. 4, Hollaender, A. (ed) Plenum Press, New York and London, p. 1-29.

(2) Ishidate, M. Jr. and Sofuni, T., (1985). The In Vitro Chromosomal Aberration Test Using Chinese Hamster Lung (CHL) Fibroblast Cells in Culture. In: Progress in Mutation Research, Vol. 5, Ashby, J. et al., (Eds) Elsevier Science Publishers, Amsterdam-New York-Oxford, p. 427-432.

(3) Galloway, S.M., Armstrong, M.J., Reuben, C., Colman, S., Brown, B., Cannon, C., Bloom, A.D., Nakamura, F., Ahmed, M., Duk, S., Rimpo, J., Margolin, G.H., Resnick, MA, Anderson, G. and Zeiger, E., (1978). Chromosome aberration and sister chromatic exchanges in Chinese hamster ovary cells: Evaluation of 108 chemicals. Environs. Molec. Mutagen 10 (suppl. 10), p. 1-175.

(4) Scott, D., Galloway, S.M., Marshall, R.R., Ishidate, M.Jr., Brusick, D., Ashby, J. and Myhr, B.C., (1991) Genotoxicity under Extreme Culture Conditions. A report from ICPEMC Task Group 9. Mutation Res, 257, p. 147-204.

(5) Morita, T., Nagaki, T., Fukuda, I. and Okumura, K., (1992). Clastogenicity of low pH to Various Cultured Mammalian Cells. Mutation Res., 268, p. 297-305.

(6) Ames, B.N., McCann, J. and Yamasaki, E., (1975). Methods for Detecting Carcinogens and Mutagens with the Salmonella/Mammalian Microsome Mutagenicity Test. Mutation Res., 31, p. 347-364.

(7) Maron, D.M. and Ames, B.N., (1983) Revised Methods for the Salmonella Mutagenicity Test. Mutation Res., 113, p. 173-215.

(8) Natarajan, A.T., Tates, A.D., van Buul, P.P.W., Meijers, M. and de Vogel, N., (1976) Cytogenetic Effects of Mutagen/Carcinogens after Activation in a Microsomal System in Vitro, I. Induction of Chromosome Aberrations and Sister Chromatid Exchange by Diethylnitrosamine (DEN) and Dimethylnitrosamine (DMN) in CHO Cells in the Presence of Rat-Liver Microsomes. Mutation Res., 37, p. 83-90.

(9) Matsuoka, A., Hayashi, M. and Ishidate, M. Jr., (1979) Chromosomal Aberration Tests on 29 Chemicals Combined with S9 Mix In Vitro. Mutation Res., 66, p. 277-290.

(10) Elliot, B.M., Combes, R.D., Elcombe, C.R., Gatehouse, D.G., Gibson, G.G., Mackay, J.M. and Wolf, R.C., (1992). Report of UK Environmental Mutagen Society Working Party. Alternatives to Aroclor 1254-induced S9 in In Vitro Genotoxicity Assays. Mutagenesis, 7, p. 175-177.

(11) Matsushima, T., Sawamura, M., Hara, K. and Sugimura, T., (1976) A Safe Substitute for Polychlorinated Biphenyls as an Inducer of Metabolic Activation Systems. In: de Serres, F.J., Fouts, J.R., Bend, J.R. and Philpot, R.M. (eds) In Vitro Metabolic Activation in Mutagenesis Testing, Elsevier, North-Holland, p. 85-88.

(12) Galloway, S.M., Aardema, M.J., Ishidate, M.Jr., Ivett, J.L., Kirkland, D.J., Morita, T., Mosesso, P., Sofuni, T., (1994) Report from Working Group on in In Vitro Tests for Chromosomal Aberrations. Mutation Res., 312, p. 241-261.

(13) Richardson, C., Williams, D.A., Allen, J.A., Amphlett, G., Chanter, D.O. and Phillips, B., (1989) Analysis of Data from In Vitro Cytogenetic Assays. In: Statistical Evaluation of Mutagenicity Test Data. Kirkland, D.J., (ed) Cambridge University Press, Cambridge, p. 141-154.

(14) Soper, K.A. and Galloway, S.M., (1994) Replicate Flasks are not Necessary for In Vitro Chromosome Aberration Assays in CHO Cells. Mutation Res., 312, p. 139-149.

(15) Krahn, D.F., Barsky, F.C. and McCooey, K.T., (1982) CHO/HGPRT Mutation Assay: Evaluation of Gases and Volatile Liquids. In: Tice, R.R., Costa, D.L., Schaich, K.M. (eds). Genotoxic Effects of Airborne Agents. New York, Plenum, p. 91-103.

(16) Zamora, P.O., Benson, J.M., Li, A.P. and Brooks, A.L., (1983) Evaluation of an Exposure System Using Cells Grown on Collagen Gels for Detecting Highly Volatile Mutagens in the CHO/HGPRT Mutation Assay. Environmental Mutagenesis, 5, p. 795-801.

(17) Locke-Huhle, C., (1983) Endoreduplication in Chinese hamster cells during alpha-radiation induced G2 arrest. Mutation Res., 119, p. 403-413.

(18) Huang, Y., Change, C. and Trosko, J.E., (1983) Aphidicolin-induced endoreduplication in Chinese hamster cells. Cancer Res., 43, p. 1362-1364.

B.11.   MUTAGENICITY — IN VIVO MAMMALIAN BONE MARROW CHROMOSOME ABERRATION TEST

1.   METHOD

This method is a replicate of the OECD TG 475, Mammalian Bone Marrow Chromosome Aberration Test (1997).

1.1.   INTRODUCTION

The mammalian in vivo chromosome aberration test is used for the detection of structural chromosome aberrations induced by the test substance to the bone marrow cells of animals, usually rodents (1)(2)(3)(4). Structural chromosome aberrations may be of two types, chromosome or chromatid. An increase in polyploidy may indicate that a chemical has the potential to induce numerical aberrations. With the majority of chemical mutagens, induced aberrations are of the chromatid-type, but chromosome-type aberrations also occur. Chromosome mutations and related events are the cause of many human genetic diseases and there is substantial evidence that chromosome mutations and related events causing alterations in oncogenes and tumour-suppressor genes are involved in cancer in humans and experimental systems.

Rodents are routinely used in this test. Bone marrow is the target tissue in this test, since it is a highly vascularised tissue, and it contains a population of rapidly cycling cells that can be readily isolated and processed. Other species and target tissues are not the subject of this method.

This chromosome aberration test is especially relevant to assessing mutagenic hazard in that it allows consideration of factors of in vivo metabolism, pharmacokinetics and DNA-repair processes although these may vary among species and among tissues. An in vivo test is also useful for further investigation of a mutagenic effect detected by in vitro test.

If there is evidence that the test substance, or a reactive metabolite, will not reach the target tissue, it is not appropriate to use this test.

See also General introduction Part B.

1.2.   DEFINITIONS

Chromatid-type aberration: structural chromosome damage expressed as breakage of single chromatids or breakage and reunion between chromatids.

Chromosome-type aberration: structural chromosome damage expressed as breakage, or breakage and reunion, of both chromatids at an identical site.

Endoreduplication: a process in which after an S period of DNA replication, the nucleus does not go into mitosis but starts another S period. The result is chromosomes with four, eight, 16, ...chromatids.

Gap: an achromatic lesion smaller than the width of one chromatid, and with minimum misalignment of the chromatid(s).

Numerical aberration: a change in the number of chromosomes from the normal number characteristic of the cells utilised.

Polyploidy: a multiple of the haploid chromosome number (n) other than the diploid number (i.e. 3n, 4n and so on).

Structural aberration: a change in chromosome structure detectable by microscopic examination of the metaphase stage of cell division, observed as deletions and fragments, intrachanges or interchanges.

1.3.   PRINCIPLE OF THE TEST METHOD

Animals are exposed to the test substance by an appropriate route of exposure and are sacrificed at appropriate times after treatment. Prior to sacrifice, animals are treated with a metaphase arresting agent (e.g. Colcemid® or colchicine). Chromosome preparations are then made from the bone marrow cells and stained, and metaphase cells are analysed for chromosome aberrations.

1.4.   DESCRIPTION OF THE TEST METHOD

1.4.1.   Preparations

1.4.1.1.   Selection of animal species

Rats, mice and Chinese hamsters are commonly used, although any appropriate mammalian species may be used. Commonly used laboratory strains of young healthy adult animals should be employed. At the commencement of the study, the weight variation of animals should be minimal and not exceed ± 20 % of the mean weight of each sex.

1.4.1.2.   Housing and feeding conditions

General conditions referred in the General introduction to Part B are applied although the aim for humidity should be 50-60 %.

1.4.1.3.   Preparation of the animals

Healthy young adult animals are randomly assigned to the control and treatment groups. Cages should be arranged in such a way that possible effects due to cage placement are minimised. The animals are identified uniquely. The animals are acclimated to the laboratory conditions for at least five days.

1.4.1.4.   Preparation of doses

Solid test substances should be dissolved or suspended in appropriate solvents or vehicles and diluted, if appropriate, prior to dosing of the animals. Liquid test substances may be dosed directly or diluted prior to dosing. Fresh preparations of the test substance should be employed unless stability data demonstrate the acceptability of storage.

1.4.2.   Test conditions

1.4.2.1.   Solvent/Vehicle

The solvent/vehicle should not produce toxic effects at the dose levels used, and should not be suspected of chemical reaction with the test substance. If other than well-known solvents/vehicles are used, their inclusion should be supported with data indicating their compatibility. It is recommended that wherever possible, the use of an aqueous solvent/vehicle should be considered first.

1.4.2.2.   Controls

Concurrent positive and negative (solvent/vehicle) controls should be included for each sex in each test. Except for treatment with the test substance, animals in the control groups should be handled in an identical manner to the animals in the treated groups.

Positive controls should produce structural aberrations in vivo at exposure levels expected to give a detectable increase over background. Positive control doses should be chosen so that the effects are clear but do not immediately reveal the identity of the coded slides to the reader. It is acceptable that the positive control be administered by a route different from the test substance and sampled at only a single time. The use of chemical class related positive control chemicals may be considered, when available. Examples of positive control substances include:



Substance

CAS No

EINECS No

Ethyl methanesulphonate

62-50-0

200-536-7

Ethyl nitrosourea

759-73-9

212-072-2

Mitomycin C

50-07-7

200-008-6

Cyclophosphamide

Cyclophosphamide monohydrate

50-18-0

6055-19-2

200-015-4

Triethylenemelamine

51-18-3

200-083-5

Negative controls, treated with solvent or vehicle alone, and otherwise treated in the same way as the treatment groups, should be included for every sampling time, unless acceptable inter-animal variability and frequencies of cells with chromosome aberrations are available from historical control data. If single sampling is applied for negative controls, the most appropriate time is the first sampling time. In addition, untreated controls should also be used unless there are historical or published control data demonstrating that no deleterious or mutagenic effects are induced by the chosen solvent/vehicle.

1.5.   PROCEDURE

1.5.1.   Number and sex of animals

Each treated and control group must include at least five analysable animals per sex. If at the time of the study there are data available from studies in the same species and using the same route of exposure that demonstrate that there are no substantial differences in toxicity between sexes, then testing in a single sex will be sufficient. Where human exposure to chemicals may be sex-specific, as for example with some pharmaceutical agents, the test should be performed with animals of the appropriate sex.

1.5.2.   Treatment schedule

Test substances are preferably administered as a single treatment. Test substances may also be administered as a split dose, i.e. two treatments on the same day separated by no more than a few hours, to facilitate administering a large volume of material. Other dose regimens should be scientifically justified.

Samples should be taken at two separate times following treatment on one day. For rodents, the first sampling interval is 1,5 normal cell cycle length (the latter being normally 12-18 hr) following treatment. Since the time required for uptake and metabolism of the test substance as well as its effect on cell cycle kinetics can affect the optimum time for chromosome aberration detection, a later sample collection 24 hr after the first sample time is recommended. If dose regimens of more than one day are used, one sampling time at 1,5 normal cell cycle lengths after t