EUR-Lex Access to European Union law

Back to EUR-Lex homepage

This document is an excerpt from the EUR-Lex website

Document 52009XC1110(01)

Commission communication in the framework of the implementation of Directive 2004/22/EC of the European Parliament and of the Council on measuring instruments (Publication of the references to normative documents drawn up by OIML and the list of the parts thereof corresponding to the essential requirements (in conformity with Article 16.1 of the Directive)) (Text with EEA relevance)

OJ C 268, 10.11.2009, p. 1–12 (BG, ES, CS, DA, DE, ET, EL, EN, FR, IT, LV, LT, HU, MT, NL, PL, PT, RO, SK, SL, FI, SV)

10.11.2009   

EN

Official Journal of the European Union

C 268/1


Commission communication in the framework of the implementation of Directive 2004/22/EC of the European Parliament and of the Council on measuring instruments (1)

(Publication of the references to normative documents drawn up by OIML and the list of the parts thereof corresponding to the essential requirements (in conformity with Article 16.1 of the Directive))

(Text with EEA relevance)

2009/C 268/01

MI-002:   Gas meters

in relation to:

OIML R 137-1 2006

Essential requirements in MID (Annex I and MI-002)

OIML R 137-1 (2006)

Comment

Annex I

 

 

1.1

5.3.1

Covered

1.2

7.4.15 table 6, A.1

Covered

1.3

7.3.5

Covered

1.3.1

5.1, A.4.2.1, A4.2.2

Covered

1.3.2

 

 

(a) M1

(a) M2

7.4.13, A.5.1, A.5.2

Covered

(a) M3

 

Not relevant

(b)

7.4.13

Covered for meter up to 10 kg

1.3.3

 

 

(a) E1

7.4.15, A.6.1.1, A.6.1.2, A.6.2, A.6.3, A.6.4, A.7.3, A.7.4, A.7.5

Covered

(a) E2

 

Not relevant

(a) E3

 

Not relevant

(b)

7.4.15

Covered

1.3.4

7.4.15, A.7

Covered for voltage variation

1.4

 

 

1.4.1

5.3.1, 7.4, A.1

Covered for class 0.5 or if MPE are fulfilled during application of influence quantities

1.4.2

A.4.2.1, A.4.2.2

Covered

2

 

Not relevant

3

7.4.4

Covered

4

6.1.3

Covered

5

7.4.9

Covered

6

3.1.1, 6.5

Covered

7

 

 

7.1

3.1.4, 4.3.1

Covered

7.2

3

Covered

7.3

7.4.11

Covered for mechanical meters

7.4

 

Not relevant

7.5

3.1.1, 3.1.4

Covered

7.6

6.2.1, 7.3.5, 7.4.16, 4.2.4.x

Covered except for test procedure

8

 

 

8.1

6.3.1, 4.3.4.2

Covered

8.2

4.3.14.3.3

Covered

8.3

7.4.16, 4.2.4, 4.3.4.1

Covered

8.4

4.3.1, 7.4.1.16

Covered

8.5

6.1.1

Covered

9

 

 

9.1

4.2.1

Covered except for the information about additional devices

9.2

4.2.1

Covered

9.3

4.2

Covered for information on data plate

9.4

 

Not relevant

9.5

6.2.2, 6.1.1

Covered

9.6

 

Not relevant

9.7

4.1

Covered

9.8

4.2

Covered

10

 

 

10.1

6.1.1

Covered

10.2

6.1.1

Covered

10.3

2.1.10, 6.3

Covered

10.4

 

Not relevant

10.5

3.1.5

Covered

11

 

 

11.1

 

Not relevant

11.2

 

Not relevant

12

 

Covered

Annex MI-002

 

 

Definitions

2.1.1, 2.3.3, 2.3.2, 2.3.4, 2.4.4 and 7.4.11

Covered

1

7.3.5

covered

1.1

5.2

Covered for class 1.5 if Qmax/Qmin ≥ 150

Covered for class 1.0 if Qmax/Qmin ≥ 20

1.2

 

Not covered

1.3

5.1

Covered

1.4

5.1

Covered except for three temperature ranges of OIML R137-1

1.5

4.2.4

Covered

2

 

 

2.1

5.3.3

Covered except for the requirement on errors of same sign in 2.1, Annex MI-002

2.2

5.3.4

Covered if selected temperature lies between 15 °C and 25 °C

3

 

 

3.1

 

 

3.1.1

7.4.15

Covered

3.1.2

7.4.15

Covered

3.1.3

7.4.15, 2.2.10

Covered for the first clause of the requirement

3.2

7.4.8

Covered

4

 

 

4.1

 

 

4.1.1

7.4.9

Covered

4.1.2

7.4.9

Covered

4.2

 

 

4.2.1

7.4.9

Not covered

4.2.2

7.4.9

Not covered

5

 

 

5.1

6.4.2

Not covered

5.2

6.4.4

Covered by one of the alternatives

5.3

6.1.2

Not covered

5.4

3.4, 7.4.5

Covered

5.5

6.2.1

Covered

5.6

3.2, 7.4.5

Covered

6

4.1

Covered if kg or m3 is used

Note:

The column ‘Comment’ indicates the compliance between OIML R 137-1 and the relevant requirement in Directive 2004/22/EC.

The indication ဘCovered’ means that:

the requirement of OIML R 137-1 is identical to the one of MID, or

the requirement of OIML R 137-1 is more severe than the one of MID, or

all of the requirement of OIML R 137-1 fulfils MID requirements (even when MID allows other alternatives),

in case the requirement is not fully covered, a short statement explains what is covered.

The indication ‘Not covered’ means that the MID requirement is either not compatible with the relevant OIML R 137-1 requirement or not included in OIML R 137-1.

The indication ‘Not relevant’ means that the MID Annex I requirement is not relevant for gas meters.

MI-002:   Volume conversion devices

in relation to:

OIML R 140 2007

Directive 2004/22/EC

Essential requirements of Annex I and Annex MI-002

OIML R 140 (2007)

Comment

Annex I

 

 

1.1

T.2.6, T.3.4, 9.1.1

Covered

1.2

T.2.16, T.2.17.2, 9.1.2, A.1

Covered for disturbances

1.3

T.1.22, 7.1.3, A.2, A.4

Covered provided the manufacturer specify all needed information

1.3.1

7.1.3, A.4.1, A.4.2, T.1.22

Covered

1.3.2 (a)

 

 

M1

M2

7.1.3, A.4.4

Covered for vibrations

M3

 

Not relevant

1.3.2 (b)

7.1.3.1, A.4.4

Covered for vibrations

1.3.3 (a)

 

 

E1

7.1.3, 10.2.8, A.4, A.4.5.a, A.4.5.b, A.4.6, A.4.7, A.4.8, A.4.11, A.4.12, A.4.13

Covered

E2

 

Not relevant

E3

 

Not relevant

1.3.3 (b)

A.4

Covered, except short interruptions in the case of DC

1.3.4

6.4.9, A.4, A.4.9, A.4.10

Covered except for mains frequency variations and power frequency magnetic fields

1.4

 

 

1.4.1

A.1, A.4

Covered if modular approach is used

1.4.2

A.4.3

Covered

2

 

Not relevant

3

 

Not covered

4

8.2.1.3, 8.6.1.3

Covered

5

9.1.1, 9.1.2, 9.1.3

Covered

6

9.1.1, 9.1.2, 9.1.3, 9.1.5, 9.3

Covered

7

 

 

7.1

7.6

Covered

7.2

7.3.4, 8.5, 8.6, 8.7

Covered

7.3

9.3.5, 9.3.6

Covered

7.4

 

Not relevant

7.5

8.6.1.1, 8.6.1.2

Covered

7.6

9.3, 10.2.3

Covered except for test procedure

8

 

 

8.1

7.1.1.1, 7.1.1.2, 7.3.2, 8.6.1.4, 8.6.1.5

Covered

8.2

7.6

Covered

8.3

7.6.2, 10.2.3

Covered except providing the identification of software on the instrument

8.4

7.6.2

Covered

8.5

7.1.4.6, 8.7.2

Not Covered

9

 

 

9.1

7.5.1, 7.5.2, 7.1.1.2

Covered for information on data plate

9.2

 

Not relevant

9.3

7.5.1, 10.2.3, 10.2.8.2

Covered

9.4

 

Not relevant

9.5

8.2.1.2, 7.1.4.1

Covered

9.6

 

Not relevant

9.7

5.1

Covered

9.8

7.5.1

Covered

10

 

 

10.1

8.2.1.1

Covered

10.2

7.1.4.1, 7.1.4.3, 8.2.1.1

Covered

10.3

T.1.5, 8.3, 8.4

Covered

10.4

 

Not relevant

10.5

 

Covered provided that the volume conversion device is equipped with a local display

11

 

 

11.1

 

Not relevant

11.2

7.1.4.6, 8.7.2, 9.1.5

Covered

12

 

Covered

Annex MI-002

 

 

Definitions

1.1, 2, 6.3, 7.3, 8.5, 8.6

Covered

Gas meter

Conversion device

Minimum flowrate

Maximum flowrate

Transitional flowrate

Overload flowrate

Base conditions

T.1.9, T.1.12, 7.3.2.1, T.1.14, 7.3.1

Covered

1

7.1.2.1, 8.6.1.1, 9.3.6

Not covered

1.1

 

Not relevant

1.2

 

Not covered

1.3

7.3, 7.5.1

Covered

1.4

7.1.3, A.4.1, A.4.2, T.1.22

Covered

1.5

7.1.3, A.4, A.4.9, A.4.10, T.1.22

Covered

2

 

 

2.1

 

Not relevant

2.2

 

Not relevant

3

 

 

3.1

 

 

3.1.1

T.2.17.2, T.2.17.4, 9.1.2, 9.1.3, 9.1.4

Covered

3.1.2

9.1.1, 9.1.2, 9.1.3, 9.1.5, 9.3.6

Covered

3.1.3

T.2.17.2

Covered

3.2

 

Not relevant

4

 

 

4.1

 

 

4.1.1

 

Not relevant

4.1.2

 

Not relevant

4.2

 

 

4.2.1

 

Not relevant

4.2.2

 

Not relevant

5

 

 

5.1

9.2.1

Not covered

5.2

9.2.2

Covered when the battery has a 5 years lifetime

5.3

 

Not relevant

5.4

 

Not relevant

5.5

 

Not relevant

5.6

 

Not relevant

6

5.1

Covered except when mass is expressed in tonnes

7

7.3.1, 10.2.2

Covered

8

6.3.3

Covered provided that ambient temperature is managed such that it remains within ± 3 °C at reference conditions and except for OIML R 140 class C

9

 

 

9.1

9.3.6

Covered

9.2

7.1.4, 8.2, 8.7.1

Covered only for parameters and provided that the conversion device is equipped with a local display

Note:

The column ‘Comment’ indicates the compliance between OIML R 140 and the relevant requirement in Directive 2004/22/EC.

The indication ‘Covered’ means that:

the requirement of OIML R 140 is identical to the one of MID, or

the requirement of OIML R 140 is more severe than the one of MID, or

all of the requirement of OIML R 140 fulfils MID requirements (even when MID allows other alternatives),

in case the requirement is not fully covered, a short statement explains what is covered.

The indication ‘Not covered’ means that the MID requirement is either not compatible with the relevant OIML R 140 requirement or not included in OIML R 140.

The indication ‘Not relevant’ means that the MID Annex I requirement is not relevant for conversion devices.

MI-007:   Taximeters

in relation to:

OIML R 21 2007

Essential requirements of Annex I and Annex MI-007

OIML R 21 (2007)

Comment

Annex I

 

 

1.1

2.4.5.4, 2.5.5

Covered

1.2

A.5.4.5

Covered

1.3

3.5.2

Covered

1.3.1

3.5.1, 5.1.2

Covered

1.3.2(a)

 

 

M1

 

Not relevant

M2

 

Not relevant

M3

A.5.4.4

Covered

1.3.2(b)

 

Covered

1.3.3(a)

 

 

E1

 

Not relevant

E2

 

Not relevant

E3

A.5.4.3, A.5.4.5, A.5.4.6, A.5.4.7

Covered when the field strength is 24 V/m

1.3.3(b)

Annex A

Covered

1.3.4

Annex A

Covered

1.4

 

 

1.4.1

A.5.1

Covered

1.4.2

5.1.2

Covered

2

7.5

Covered

3

5.2.6

Covered

4

 

Covered

5

4.1

Covered

6

3.3

Covered

7

 

 

7.1

4.2.1

Covered

7.2

4.1, 4.9.1

Covered

7.3

 

Not relevant

7.4

 

Not relevant

7.5

4.1

Covered

7.6

4.2.3, 4.11

Covered when the test procedure is included in the operation manual

8

 

 

8.1

5.2.3.2

Covered

8.2

4.2.5

Covered

8.3

4.11.2.

Covered

8.4

4.10

Covered

8.5

 

Not relevant

9

 

 

9.1

4.12, 4.12.1

Covered

9.2

 

Not relevant

9.3

 

Not covered

9.4

 

Not relevant

9.5

 

Not relevant

9.6

 

Not relevant

9.7

3.4, 4.9.1

Covered

9.8

4.12.2

Covered

10

 

 

10.1

4.9.1

Covered

10.2

4.9.1

Covered

10.3

4.9.2

Covered

10.4

4.9.1

Covered

10.5

 

Not relevant

11

 

 

11.1

 

Not relevant

11.2

 

Not relevant

12

4.2.3

Covered

Annex MI-007

 

 

Definitions

 

 

Taximeter

2.1.1

Covered

Fare

2.3.1.1

Covered

Cross-over speed

2.3.1.2

Covered

Normal calculation mode S (single application of tariff)

2.3.1.3.1

Covered

Normal calculation mode D (double application of tariff)

2.3.1.3.2

Covered

Operating position

2.3.3, 2.3.3.1, 2.3.3.2, 2.3.3.3

Covered

1

3.1

Covered

2

2.3.3.2, 2.3.3.3, 3.1

Covered

3

4.3

Covered

4

5.2.3, 4.2.2

Covered

5

4.2.3, 4.2.5

Covered

6.1

A.5.4.4

Covered

6.2

3.5.1, 3.5.2

Covered

7

3.2.1.1

Covered

8

 

 

8.1

See Answer to Annex I § 1.3.3

Covered

8.2

5.1.3

Covered

9

5.2.5

Covered

10

3.1

Covered

11

4.5.3(b)

Covered

12

4.5.4

Covered

13

4.9.1

Covered

14.1

4.2.4

Covered

14.2

4.2.5

Covered when 4.2.5.i of OIML R 21:2007 is mandatory

14.3

See answer to Annex I § 8.3

Covered

15.1

4.7

Covered

15.2

4.7

Covered

15.3

4.9.1

Covered

16

4.8

Covered

17

4.1, 4.14.1

Covered

18

5.2.4, 3.2.1.1

Covered

19

4.14.1, 4.2.1

Covered

20

4.2.1

Covered

21

3.3

Covered

22

3.7

Covered

23

3.4

Covered

Note:

The column ‘Comment’ indicates the compliance between OIML R 21 and the relevant requirement in Directive 2004/22/EC.

The indication ‘Covered’ means that:

the requirement of OIML R 21 is identical to the one of MID, or

the requirement of OIML R 21 is more severe than the one of MID, or

all of the requirement of OIML R 21 fulfils MID requirements (even when MID allows other alternatives),

in case the requirement is not fully covered, a short statement explains what is covered.

The indication ‘Not covered’ means that the MID requirement is either not compatible with the relevant OIML R 21 requirement or not included in OIML R 21.

The indication ‘Not relevant’ means that the MID Annex I requirement is not relevant for taxi meters.

MI-008 CHAPTER II:   Capacity serving measures

in relation to:

OIML R 138 2007

Essential requirements in MID (Annex I and Annex MI-008 II)

OIML R 138 (2007)

Comment

Annex I

 

 

1.1

5.1

Covered

1.2

 

Not relevant

1.3

 

Not relevant

1.3.1

 

Not relevant

1.3.2(a)

 

Not relevant

1.3.2(b)

 

Not relevant

1.3.3(a)

 

Not relevant

1.3.3(b)

 

Not relevant

1.3.4

 

Not relevant

1.4

 

 

1.4.1

 

Not relevant

1.4.2

 

Not relevant

2

 

Not covered

3

 

Not covered

4

4.4

Covered

5

4.2

Covered

6

 

Not covered

7

 

 

7.1

 

Not covered

7.2

4.2

Covered

7.3

 

Not relevant

7.4

 

Not relevant

7.5

4.2

Covered

7.6

 

Not relevant

8

 

 

8.1

 

Not relevant

8.2

 

Not relevant

8.3

 

Not relevant

8.4

 

Not relevant

8.5

 

Not relevant

9

 

 

9.1

5.2.4, 5.2.1, 5.2.5

Covered when the reference temperature is 20 °C

9.2

 

Not relevant

9.3

 

Not relevant

9.4

 

Not relevant

9.5

 

Not relevant

9.6

5.2.1

Covered

9.7

3

Covered when units are SI units

9.8

5.2.1

Covered

10

 

 

10.1

 

Not relevant

10.2

5.2.1

Covered

10.3

 

Not relevant

10.4

 

Not relevant

10.5

 

Not relevant

11

 

 

11.1

 

Not relevant

11.2

 

Not relevant

12

 

Covered

Annex MI-008 Chapter II

 

 

Definitions

 

 

Capacity serving measure

2.2

Covered

Line measure

2.9

Covered when the gauge mark is a line

Brim measure

2.7

Covered

Transfer measure

2.2

Covered

Capacity

2.7, 2.5, 2.9, 4.6.1

Covered

1

 

 

1.1

5.2.5

Covered when the reference temperature is 20 °C

1.2

4.5

Covered

2

5.1.1, 4.1.1

Covered

3

4.2

Covered

4

 

 

4.1

4.4

Covered

4.2

 

Not covered

5

 

 

5.1

5.2.1

Covered

5.2

5.2.2

Covered when there are no more than 3 capacities marked

5.3

4.2, 5.2.2

Covered

Note:

The column ‘Comment’ indicates the compliance between OIML R 138 and the relevant requirement in Directive 2004/22/EC.

The indication ‘Covered’ means that:

the requirement of OIML R 138 is identical to the one of MID, or

the requirement of OIML R 138 is more severe than the one of MID, or

all of the requirement of OIML R 138 fulfils MID requirements (even when MID allows other alternatives),

in case the requirement is not fully covered, a short statement explains what is covered.

The indication ‘Not covered’ means that the MID requirement is either not compatible with the relevant OIML R 138 requirement or not included in OIML R 138.

The indication ‘Not relevant’ means that the MID Annex I requirement is not relevant for capacity serving measures.


(1)  OJ L 135, 30.4.2004.


Top