EUR-Lex Access to European Union law

Back to EUR-Lex homepage

This document is an excerpt from the EUR-Lex website

Document 31982L0624

Commission Directive 82/624/EEC of 1 July 1982 adapting to technical progress Council Directive 76/765/EEC on the approximation of the laws of the Member States relating to alcoholometers and alcohol hydrometers

OJ L 252, 27.8.1982, p. 8–9 (DA, DE, EL, EN, FR, IT, NL)
Spanish special edition: Chapter 13 Volume 012 P. 256 - 257
Portuguese special edition: Chapter 13 Volume 012 P. 256 - 257
Special edition in Finnish: Chapter 13 Volume 012 P. 110 - 111
Special edition in Swedish: Chapter 13 Volume 012 P. 110 - 111
Special edition in Czech: Chapter 13 Volume 006 P. 336 - 337
Special edition in Estonian: Chapter 13 Volume 006 P. 336 - 337
Special edition in Latvian: Chapter 13 Volume 006 P. 336 - 337
Special edition in Lithuanian: Chapter 13 Volume 006 P. 336 - 337
Special edition in Hungarian Chapter 13 Volume 006 P. 336 - 337
Special edition in Maltese: Chapter 13 Volume 006 P. 336 - 337
Special edition in Polish: Chapter 13 Volume 006 P. 336 - 337
Special edition in Slovak: Chapter 13 Volume 006 P. 336 - 337
Special edition in Slovene: Chapter 13 Volume 006 P. 336 - 337
Special edition in Bulgarian: Chapter 13 Volume 006 P. 68 - 69
Special edition in Romanian: Chapter 13 Volume 006 P. 68 - 69
Special edition in Croatian: Chapter 13 Volume 057 P. 9 - 10

Legal status of the document No longer in force, Date of end of validity: 01/12/2015; Implicitly repealed by 32011L0017

ELI: http://data.europa.eu/eli/dir/1982/624/oj

31982L0624

Commission Directive 82/624/EEC of 1 July 1982 adapting to technical progress Council Directive 76/765/EEC on the approximation of the laws of the Member States relating to alcoholometers and alcohol hydrometers

Official Journal L 252 , 27/08/1982 P. 0008 - 0009
Finnish special edition: Chapter 13 Volume 12 P. 0110
Spanish special edition: Chapter 13 Volume 12 P. 0256
Swedish special edition: Chapter 13 Volume 12 P. 0110
Portuguese special edition Chapter 13 Volume 12 P. 0256


COMMISSION DIRECTIVE of 1 July 1982 adapting to technical progress Council Directive 76/765/EEC on the approximation of the laws of the Member States relating to alcoholometers and alcohol hydrometers (82/624/EEC)

THE COMMISSION OF THE EUROPEAN COMMUNITIES,

Having regard to the Treaty establishing the European Economic Community,

Having regard to Council Directive 71/316/EEC of 26 July 1971 on the approximation of the laws of the Member States relating to common provisions for both measuring instruments and methods of metrological control (1), as last amended by the Act of Accession of Greece, and in particular Article 17 thereof,

Whereas, since the adoption of Directive 76/765/EEC (2), new techniques have been developed in the field of thermometers used in determining alcoholic strength ; whereas that Directive should be amended accordingly;

Whereas the measures provided for in this Directive are in accordance with the Committee on the Adaptation to Technical Progress of the Directives for the Elimination of Technical Barriers to Trade in Measuring Instruments,

HAS ADOPTED THIS DIRECTIVE:

Article 1

The text of section 9 of the Annex to Directive 76/765/EEC is hereby replaced in accordance with the Annex to this Directive.

Article 2

Member States shall bring into force the laws, regulations and administrative provisions necessary in order to comply with this Directive on 1 May 1983. They shall forthwith inform the Commission thereof.

Article 3

This Directive is addressed to the Member States.

Done at Brussels, 1 July 1982.

For the Commission

Karl-Heinz NARJES

Member of the Commission (1) OJ No L 202, 6.9.1971, p. 1. (2) OJ No L 262, 27.9.1976, p. 143.

ANNEX

9. THERMOMETERS USED IN DETERMINING ALCOHOLIC STRENGTH

9.1. Thermometers incorporated in the instrument used to determine alcoholic strength

If the instrument used to determine alcoholic strength belongs to Class II or III, a thermometer of the mercury-expansion type with glass casing may be incorporated therein. 9.1.1. The thermometer shall be graduated to 0 71 or 0 72 or 0 75 °C and it need not have any scale mark at 0 °C.

9.1.2. The minimum scale spacing shall be:

0 78 mm in the case of thermometers graduated to 0 71 and 0 72 °C;

1 70 mm in the case of thermometers graduated to 0 75 °C.

9.1.3. The thickness of the lines shall not be more than one fifth of the scale spacing.

9.1.4. The maximum permissible error, positive or negative, shall be:

0 710 °C if the thermometer is graduated to 0 71 °C;

0 720 °C if the thermometer is graduated to 0 72 or 0 75 °C.

9.1.5. During EEC initial verification, the error of the incorporated thermometer shall be determined at a minimum of three points in the scale range.

9.2. Thermometers not incorporated in an instrument used to determine alcoholic strength 9.2.1. If the instrument used to determine alcoholic strength belongs to Class I, the thermometer employed in conjunction with it shall be: - either of the metallic resistance type, enabling the temperature of the mixture of water and alcohol to be determined with a maximum permissible error of ± 0 710 °C,

- or of the mercury-expansion type with a glass casing graduated to 0 71 or 0 75 °C.

Mercury thermometers shall have a scale mark at 0 °C, the minimum scale spacing shall be 0 78 mm and the thickness of the lines shall not be more than one fifth of the scale spacing.

The maximum permissible error, positive or negative, shall be one scale interval.

9.2.2. If the instrument used to determine alcoholic strength belongs to Class II or III, the thermometer employed in conjunction with it shall be of the mercury-expansion type with glass casing. 9.2.2.1. The thermometer shall be graduated to 0 71 or 0 72 or 0 75 °C. It shall have a scale mark at 0 °C.

9.2.2.2. The minimum scale spacing shall be:

0 78 mm in the case of thermometers graduated to 0 71 or 0 72 °C;

1 70 mm in the case of thermometers graduated to 0 75 °C.

9.2.2.3. The thickness of the lines shall not be more than one fifth of the scale spacing.

9.2.2.4. The maximum permissible error shall be:

± 0 710 °C if the thermometer is graduated to 0 71 °C;

± 0 720 °C if the thermometer is graduated to 0 72 or 0 75 °C.

Top